RAPID WATER QUALITY KIT FOR PRODUCED WATER REUSE: ONSHORE PRODUCTION POWER ACROSS TEXAS ENERGY CHALLENGE MAY 1, 2015 Omar Ghannoum Preston Tidwell Allana Robertson Nima Ghahremani 1

Transcript of RAPID WATER QUALITY KIT FOR PRODUCED WATER REUSE: ONSHORE PRODUCTION POWER ACROSS TEXAS ENERGY...

Page 1: RAPID WATER QUALITY KIT FOR PRODUCED WATER REUSE: ONSHORE PRODUCTION POWER ACROSS TEXAS ENERGY CHALLENGE MAY 1, 2015 Omar Ghannoum Preston Tidwell Allana.

1

RAPID WATER QUALITY KIT FOR PRODUCED WATER REUSE: ONSHORE PRODUCTION

POWER ACROSS TEXAS ENERGY CHALLENGE

MAY 1, 2015

Omar GhannoumPreston TidwellAllana Robertson Nima Ghahremani

Page 2: RAPID WATER QUALITY KIT FOR PRODUCED WATER REUSE: ONSHORE PRODUCTION POWER ACROSS TEXAS ENERGY CHALLENGE MAY 1, 2015 Omar Ghannoum Preston Tidwell Allana.

AGENDA

• Introduce the idea• Portable Frac Water kit

• Explain the importance• Water usage• Who will benefit

• The portable frac kit• How it works• Quality Control• Bacteria• Chemistry

• Conclusion

2

Page 3: RAPID WATER QUALITY KIT FOR PRODUCED WATER REUSE: ONSHORE PRODUCTION POWER ACROSS TEXAS ENERGY CHALLENGE MAY 1, 2015 Omar Ghannoum Preston Tidwell Allana.

AN INNOVATIVE FRAC WATER TESTING KIT

• Onsite testing of water to be used for Hydraulic Fracturing mixtures

• Will be used as a way to screen good water from bad water

• It’s cheap and quick

• Will be a catalyst to new innovations in oil field water usage

3

Page 4: RAPID WATER QUALITY KIT FOR PRODUCED WATER REUSE: ONSHORE PRODUCTION POWER ACROSS TEXAS ENERGY CHALLENGE MAY 1, 2015 Omar Ghannoum Preston Tidwell Allana.

CURRENT WATER PROBLEMS IN TEXAS

• A typical shale well uses 5M gallons of water for hydraulic fracturing

• 7 Billion bbls Produced water per year in the Eagle Ford formation (Adham 2014, USDOE)

• 40% of water used for fracing comes back up to the surface

• Handling water is expensive

Fresh water costs: $0.88-6.05/bbl

Disposal costs: $1.13-$10.75/bbl

Water management accounts for up to 10% of well costs (IHS)

Frac Pond (Energy Corp. of America)

• Important chemistries in produced water prevent us from using it directly due to compatibility issues (Blauch 2010)

4

Page 5: RAPID WATER QUALITY KIT FOR PRODUCED WATER REUSE: ONSHORE PRODUCTION POWER ACROSS TEXAS ENERGY CHALLENGE MAY 1, 2015 Omar Ghannoum Preston Tidwell Allana.

WATER IN HYDRAULIC FRACTURING FLUIDS

• Slick Water

• Sand + Water + Acid

• Pumped at extremely high rates (60-100 BPM) to achieve fracture

• Cross Linker Gel

• Sand + Water + Acid + Guar Gel

• Uses high viscosity and density to achieve fractures

5

Page 6: RAPID WATER QUALITY KIT FOR PRODUCED WATER REUSE: ONSHORE PRODUCTION POWER ACROSS TEXAS ENERGY CHALLENGE MAY 1, 2015 Omar Ghannoum Preston Tidwell Allana.

WHAT IS PRESENTLY DONE

Currently produced water is: • Re-injected into reservoir to maintain pressure, 56% • Pumped into disposal wells, 39%• A small percentage is cleaned and recycled, about, 3%

Cleaned using: • Coagulation, hydrocyclones, coalescers, flotation, and micro, ultra,

nano, and reverse osmosis filtration systems

Drillin

gco

ntra

ctor.o

rg

(Al-Maamari 2014); (USDOE); (EOR)

6

Page 7: RAPID WATER QUALITY KIT FOR PRODUCED WATER REUSE: ONSHORE PRODUCTION POWER ACROSS TEXAS ENERGY CHALLENGE MAY 1, 2015 Omar Ghannoum Preston Tidwell Allana.

WHO CAN BENEFIT FROM THE KIT?

• Service companies (Halliburton, Schlumberger, NOV)

• These companies are responsible for the quality of hydraulic fracturing job

• Can use the kit to help them cut costs and deliver a better product

• Lower oil prices means lower margins, and every bit counts

• Operators

• Lower water handling costs

• Can make locals happy because of less water usage

• Wastewater management is the primary driver of costs

7

Page 8: RAPID WATER QUALITY KIT FOR PRODUCED WATER REUSE: ONSHORE PRODUCTION POWER ACROSS TEXAS ENERGY CHALLENGE MAY 1, 2015 Omar Ghannoum Preston Tidwell Allana.

RAPID CHEMISTRY KIT FOR COMPATIBILITY TESTING

Boron

Barium

Bacteria

Chloride

pH

Iron

Sulfate

Total Suspended

Solids

Acidity

5 mg/L

40 mg/L

2500 ATP

30,000 mg/L

4-9

70 mg/L

400 mg/L

500 mg/L

5000 mg/LCalcium 500 mg/L

Photo from LaMotte Corp.

Chemical Tested

Chemical Tested

Suggested Levels

Suggested Levels

• < 8 = Good• 4-8 = Some filtration/mixing

needed• > 4 = Extensive filtration

needed

8

Page 9: RAPID WATER QUALITY KIT FOR PRODUCED WATER REUSE: ONSHORE PRODUCTION POWER ACROSS TEXAS ENERGY CHALLENGE MAY 1, 2015 Omar Ghannoum Preston Tidwell Allana.

WHY IS WATER CHEMISTRY IMPORTANT ?

• Interference with friction reducers• Chlorides (+)• Calcium (+)• Magnesium(

+)

• Bacteria

• Clogs pores• TSS/TDS• Creates friction• Scaling

• Hydration of Crosslinker• Boron• Iron• Sulfate

9

Page 10: RAPID WATER QUALITY KIT FOR PRODUCED WATER REUSE: ONSHORE PRODUCTION POWER ACROSS TEXAS ENERGY CHALLENGE MAY 1, 2015 Omar Ghannoum Preston Tidwell Allana.

WATER REUSE IN COMPLETION ACTIVITIES

Flow back fluid and recycled fluid from Baaken: photo by SIONIX

• Flow Back or Produced Water contains high concentrations of a variety of ions

• Kit can determine water compatibility for operations

• Pre and post cleaning chemical levels

Flow Back Cleaned

10

Page 11: RAPID WATER QUALITY KIT FOR PRODUCED WATER REUSE: ONSHORE PRODUCTION POWER ACROSS TEXAS ENERGY CHALLENGE MAY 1, 2015 Omar Ghannoum Preston Tidwell Allana.

SCALING TENDENCIES

1. Scaling: Oil and gas recovery reduction due to the formation of typical scales such as sulfate salts of calcium, strontium, and barium.

Example Scaling Problem:

Assumptions:Flowback water has 20 mg/L of Ba2+

Groundwater has 200 mg/L of SO4

2-

Temperature = 25 °C (at surface)11

Page 12: RAPID WATER QUALITY KIT FOR PRODUCED WATER REUSE: ONSHORE PRODUCTION POWER ACROSS TEXAS ENERGY CHALLENGE MAY 1, 2015 Omar Ghannoum Preston Tidwell Allana.

IMPORTANCE: CORROSION MANAGEMENT

Chemical

Corrosion/Scalin

g

Microbial

Influenced

Corrosion

Equipment Failures &

Environmental Incidents

Duncan, K.E, Perez-Ibarra, B.M., Jenneman, G., Harris, J.B., Webb, R., Sublette,K. 2013. The effect of corrosion inhibitors on microbial communities associated with corrosion in a model flow cell system. Applied Microbiology and Biotechnology 98:907-918.

12

Page 13: RAPID WATER QUALITY KIT FOR PRODUCED WATER REUSE: ONSHORE PRODUCTION POWER ACROSS TEXAS ENERGY CHALLENGE MAY 1, 2015 Omar Ghannoum Preston Tidwell Allana.

WHY IS WATER BIOLOGY IMPORTANT?

Microbes in the water column: Planktonic

Microbes attached to surface: Sessile

Attachment

Cell-to-cell adhesion

Growth Matures & Releases

Davis Lab: http://www.binghamton.edu/biology/faculty/davies/research.htmBaldwin, P., Mulliniks, B., 2015. Chemical-Free Bacteria Neutralization and In-Field Testing. (emailed copy prior to publication at a conference).

13

Page 14: RAPID WATER QUALITY KIT FOR PRODUCED WATER REUSE: ONSHORE PRODUCTION POWER ACROSS TEXAS ENERGY CHALLENGE MAY 1, 2015 Omar Ghannoum Preston Tidwell Allana.

9 MAJOR MICROBIAL INFLUENCED CORROSION GROUPS

(SRB) Sulfate-reducing

(TRB) Thiosulfate-reducing

(NRB) Nitrate-reducing

(SuRB) Sulfite-producing

(IOB) Iron-oxidizing

(APB) Acid-producing

(IRB) Iron-reducing

Methanogens

(SPB) Slime-producing

Note: (SPB) also classified as (EPS) Extra polymeric substance producing

Sherman, S., Brownlee, D., kakadjian, SPE,S., Luft, B., Trican Well Service Ltd. 2014. Microbial Influenced Corrosion of Coil Tubing Milling Strings in the Eagle Ford Shale. No. IPTC-18032-MS. International Petroleum Technology Conference, Kuala Lumpur, Malaysia (2014).

14

Page 15: RAPID WATER QUALITY KIT FOR PRODUCED WATER REUSE: ONSHORE PRODUCTION POWER ACROSS TEXAS ENERGY CHALLENGE MAY 1, 2015 Omar Ghannoum Preston Tidwell Allana.

MOBILE MONITORING OPTIONS

Molecular Technology

Ease of Use

Testing Time (min)

Portability

Accuracy Microbial Activity Tested

Cost per Test

ATP LuminUltra

Easy 5 Very Good Good All (viable & nonviable)

$7

Bactiquant Moderate 11 Very Good Good All (viable only)

$20

QuickChek SRB

Moderate 10 Very Good OK SRB (viable & nonviable)

$14

Rapid-B Flow Cytometer

Easy 3 Benchtop Based

Very Good All (viable only)

$20

Bug Bottles

Easy 5-7 days Benchtop Based

OK Specific to Media (viable only)

$0.60

http://www.hach.com/quick.search-quick.search.jsa?keywords=ATP+LuminUltra http://www.modernwater.com/monitoring/by-industry/oil-and-gas

(Victor Pena Sales Account Manager)http://www.mycometer.com/ http://www.biotechnologysolutions.com/ http://www.pcbdservices.com/technology/oil-and-gas.php

15

Page 16: RAPID WATER QUALITY KIT FOR PRODUCED WATER REUSE: ONSHORE PRODUCTION POWER ACROSS TEXAS ENERGY CHALLENGE MAY 1, 2015 Omar Ghannoum Preston Tidwell Allana.

MMM’S IN USE AT ENCANA FIELD SITE, PERMIAN BASIN

Rapid-B Flow Cytometer

ATP LuminUltraBactiquant

Industry Standard Bug Bottles

16

Page 17: RAPID WATER QUALITY KIT FOR PRODUCED WATER REUSE: ONSHORE PRODUCTION POWER ACROSS TEXAS ENERGY CHALLENGE MAY 1, 2015 Omar Ghannoum Preston Tidwell Allana.

COMPARISON BETWEEN KIT AND LAB ANALYSIS

Note: Boron, Barium and Sulfate were below MDL of the field kit; TDS was above the detection limit

(Results of water chemistry analyses for “Earlyne SWD 2/25/15” performed with field water test kit)

1

10

100

1,000

10,000

100,000

, 25,800 , 22,400

, 80.5 , 72

, 1,700

, 220

, 2852

, 940

, 50.5 , 45.1

, 577 , 600

, 6.83 , 6.6

, 860

Chloride Iron Alkalinity Calcium Conductivity, mS/cmTurbidity, FAU TSS, lab pH Acidity

Conc

entr

ation

(mg/

L)

17

Page 18: RAPID WATER QUALITY KIT FOR PRODUCED WATER REUSE: ONSHORE PRODUCTION POWER ACROSS TEXAS ENERGY CHALLENGE MAY 1, 2015 Omar Ghannoum Preston Tidwell Allana.

LETS REVIEW: RAPID CHEMISTRY KIT FOR COMPATIBILITY TESTING

The main purpose of our kit is to: • Only takes 1 hour to complete all the tests• Identify ‘good’ and ‘bad’ water on site• Less than 5% error compared to certified lab• Provide a reasonable estimate of contamination levels• Less than $20 to complete all tests

As a result of using our kit, you should see a reduction in: • Less down time on rig site• Fresh water needed for completion activities • Expenses related to water purchase • Tensions between local communities and production

companies

TimeMone

y$$

18

Page 19: RAPID WATER QUALITY KIT FOR PRODUCED WATER REUSE: ONSHORE PRODUCTION POWER ACROSS TEXAS ENERGY CHALLENGE MAY 1, 2015 Omar Ghannoum Preston Tidwell Allana.

ACKNOWLEDGMENT

Michael Irlbeck Mika Bradford & The Vivione FieldTeam

Jennifer Fichter Ecolyse Field Scientists

David Burnett & The GPRI Team Dr. Lee Clapp; Environmental Engineering

Dr. Lucy Camacho; Environmental Engineering

19Research Partnership to Secure Energy for America

Page 20: RAPID WATER QUALITY KIT FOR PRODUCED WATER REUSE: ONSHORE PRODUCTION POWER ACROSS TEXAS ENERGY CHALLENGE MAY 1, 2015 Omar Ghannoum Preston Tidwell Allana.

QUESTIONS?

20