SRD Plans comply Rapid Shutdown requirements for 2014 NEC and 2016 CEC 690.12
How to Comply
Microinverter systems automatically comply with rapid shutdown.
The PV system shuts down completely upon loss of utility power.
SRD plan sets now include the Rapid Shutdown label.
Less than 10 feet from array: No additional switches are needed. The DC disconnect at the
sting inverter initiates rapid shutdown.
More than 10 feet from array: One or more rapid shutdown boxes are required. Fronius Rapid
Shutdown Boxes have been added to the SRD Price List.
STRINGINVERTERS
Optimizer systems (DC-DC converters) automatically comply with rapid
shutdown.The DC Disconnect at the string inverter initiates rapid shutdown.
ENPHASE SYSTEMS
SOLAREDGESYSTEMS
RAPID SHUTDOWN
General Resources Product Resourceshttp://solarprofessional.com/arti
cles/design-installation/rapid-
shutdown-for-pv-systems
HISTORY OF RAPID SHUTDOWN
ALL SYSTEMS MUST POST A RAPID SHUTDOWN LABEL AT THE MAIN SERVICE PANEL
VISUAL OF REQUIREMENTS BY INVERTER
http://solarprofessional.com/sites/
default/files/articles/ajax/docs/SP
8_1_Brooks_WebExtras.pdf
SOLAREDGE RAPID SHUTDOWN VIDEO
ENPHASE RAPID SHUTDOWN
https://www.youtube.com/watch?v=Wd9OhYxNg48
https://enphase.com/en-us/support/enphase-topic-
brief-rapid-shutdown
Questions?Nick [email protected]
FRONIUS RAPID SHUTDOWN
SMA RAPID SHUTDOWN
https://tinyurl.com/fronius-rapid-shutdown
http://www.sma-america.com/products/dc-
technology/rapid-shutdown-system.html
/ Perfect Welding / Solar Energy / Perfect Charging
RATED NEMA 4X
/ Built for severe outdoor conditions./ Robust metal housing./ Rated for rooftop install.
MOUNTING
/ Mounting bracket included./ Can be mounted, per NEC 2014, on the roof or racking within 10 feet from the array or in the attic 5 feet within the array.
/ Input and output terminals are spring loaded for fast and easy connection without special tools.
RAPID SHUTDOWN BOX
/ The Fronius Rapid Shutdown Box provides the ultimate NEC 2014 code (690.12) compliant solution while enhancing rooftop and firefighter safety. With the Fronius Rapid Shutdown Box, Fronius offers a reliable and easy to install solution for all Fronius SnapINverters in systems up to 600 V.*
/ Directly connected to the inverter through the same conduit as the DC homeruns, the Fronius solution minimizes the number of components needed providing ease of installation. No additional power supply is needed, reducing overall system cost and streamlining installation. Rapid Shutdown is triggered whenever AC is not present and the inverter rapidly discharges the DC lines, allowing for a seamless code compliant solution to the 2014 NEC requirement for rapid shutdown functionality for PV systems on buildings.
SAMPLE CONFIGURATION
/ The reliable rapid shutdown solution for Fronius inverters.
PV ARRAY
FRONIUS RAPIDSHUTDOWN BOX
Communication path DC line
FRONIUS INVERTER
within 10 ft
ONE CONDUIT
SINGLE STRING AND MULTI STRING VERSIONS AVAILABLE
TERMINALS
* Excluding the Fronius Symo 15.0 -3 208 / Fronius Galvo only works with Fronius Rapid Shutdown Box Single
/ Perfect Welding / Solar Energy / Perfect Charging
v05 May 2015 EN
Text
and
imag
es c
orre
spon
d to
the
cur
rent
sta
te o
f te
chno
logy
at t
he t
ime
of p
rint
ing.
Sub
ject
to m
odif
icat
ions
.A
ll in
form
atio
n is
wit
hout
gua
rant
ee in
spi
te o
f ca
refu
l edi
ting
- li
abil
ity
excl
uded
. Cop
yrig
ht ©
201
1 Fr
oniu
s™. A
ll ri
ghts
res
erve
d.
Further information about all Fronius products and our global sales partners and representatives can be found at www.fronius.com
WE HAVE THREE DIVISIONS AND ONE PASSION: SHIFTING THE LIMITS OF POSSIBILITY./ Whether welding technology, photovoltaics or battery charging technology − our goal is clearly defined: to be the innovation leader. With around 3,300 employees worldwide, we shift the limits of what’s possible - our record of over 900 granted patents is testimony to this. While others progress step by step, we innovate in leaps and bounds. Just as we’ve always done. The responsible use of our resources forms the basis of our corporate policy.
Fronius USA LLC 6797 Fronius DrivePortage, IN [email protected] Version 1.1 11/7/16
TECHNICAL DATA
RAPID SHUTDOWN BOX SINGLE STRING MULTI STRING
Max. number of strings 1 input / 1 output 1 to 4 inputs / 1 or 2 outputs (each output is independent)**
Max. output current 17 A 25 A per channelMax. input current 17 A 12.5 A per inputMax. voltage 600 VPower supply DC powered by the array (max. 3W)Dimensions (W x H x D) 7.9 x 5.5 x 3.5 in. 11 x 7 x 4 in.Weight 4.4 lbs. 8.6 lbs.Max. DC homerun wire size AWG 10 AWG 8DC disconnect NA IntegratedProtection class NEMA 4XTemperature range -40° - 140° F (-40° - +60° C)DC input wire size AWG 10 to AWG 12Max. communication wire size AWG 14 (rated for max. system voltage)Number of conduit ports 2 1Conduit size 3/4 in. 1 in.
Compatible invertersFronius Galvo, Fronius Primo, Fronius
Symo (excluding the Fronius Symo 15.0-3 208)
Fronius Primo***, Fronius Symo (exclu-ding the Fronius Symo 15.0-3 208)
External hardware required None NoneCertifications and compliance with standards UL1741, FCC Part 15 Class B, NEC 690.12
**Note: Consult installation guide for wiring instructions on the Primo 10.0 to 15.0 kW.
***Note: For automatic rapid shutdown functionality, the Primo 10-15kW must have a serial number 27384701 or greater. Power stage SW2 seen in the inverter display “info” menu under “versions” must be 0.6.34.4 or greater. Updates are available through software update file version fro27350.upd and can be easily downloaded at www.Fronius-usa.com/Primo-Update and installed via USB stick or remote update via Fronius Solar.web.
© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein
are trademarks of their respective owners. Date: 11/2016. V.01. Subject to change without notice.
Single Phase Inverters for North America SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A-US / SE10000A-US / SE11400A-US
SE3000A-US SE3800A-US SE5000A-US SE6000A-US SE7600A-US SE10000A- US SE11400A-US OUTPUT
NominalACPowerOutput 3000 3800 5000 6000 7600 9980@208V10000@240V 11400 VA
Max.ACPowerOutput 3300 4150 5400@208V5450@240V 6000 8350 10800@208V
10950@240V 12000 VA
ACOutputVoltageMin.-Nom.-Max.(1) 183-208-229Vac - - 3 - - 3 -
ACOutputVoltageMin.-Nom.-Max.(1) 211-240-264Vac 3 3 3 3 3 3 3
ACFrequencyMin.-Nom.-Max.(1) 59.3-60-60.5 Hz
Max.ContinuousOutputCurrent 12.5 16 24@208V 21@240V 25 32 48@208V
42@240V 47.5 A
GFDIThreshold 1 AUtilityMonitoring,IslandingProtection,CountryConfigurableThresholdsYes YesINPUT MaximumDCPower (STC) 4050 5100 6750 8100 10250 13500 15350 WTransformer-less,Ungrounded Yes Max.InputVoltage 500 VdcNom.DCInputVoltage 325@208V/350@240V Vdc
Max.InputCurrent(2) 9.5 13 16.5@208V 15.5@240V 18 23 33@208V
30.5@240V 34.5 Adc
Max.InputShortCircuitCurrent 45 AdcReverse-PolarityProtection Yes Ground-FaultIsolationDetection 600k Sensitivity MaximumInverterEfficiency 97.7 98.2 98.3 98.3 98 98 98 %
CECWeightedEfficiency 97.5 98 97@208V98@240V 97.5 97.5 97@208V
97.5@240V 97.5 %
NighttimePowerConsumption <2.5 <4 WADDITIONAL FEATURESSupportedCommunicationInterfaces RS485,RS232,Ethernet,ZigBee(optional)RevenueGradeData,ANSIC12.20 Optional(3)
RapidShutdown–NEC2014690.12 YesSTANDARD COMPLIANCESafety UL1741,UL1741SA,UL1699B,UL1998,CSA22.2 GridConnectionStandards IEEE1547 Emissions FCCpart15classB INSTALLATION SPECIFICATIONS ACoutputconduitsize/AWGrange 3/4”minimum/16-6AWG 3/4”minimum/8-3AWG DCinputconduitsize/#ofstrings/AWGrange 3/4”minimum/1-2strings/16-6AWG 3/4”minimum/1-3strings/
14-6AWGDimensionswithSafetySwitch(HxWxD) 30.5x12.5x7.2/775x315x184 30.5x12.5x10.5/
775x315x260in/mm
WeightwithSafetySwitch 51.2/23.2 54.7/24.7 88.4/40.1 lb/kg
Cooling NaturalConvection
Naturalconvectionandinternalfan(user
replaceable)
Fans(userreplaceable)
Noise <25 <50 dBAMin.-Max.OperatingTemperatureRange -13to+140/-25to+60(-40to+60versionavailable(4)) ˚F/˚C
ProtectionRating NEMA3R(1)ForotherregionalsettingspleasecontactSolarEdgesupport.(2)Ahighercurrentsourcemaybeused;theinverterwilllimititsinputcurrenttothevaluesstated.(3)RevenuegradeinverterP/N:SExxxxA-US000NNR2(for7600Winverter:SE7600A-US002NNR2).(4)-40versionP/N:SExxxxA-US000NNU4(for7600Winverter:SE7600A-US002NNU4).
© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein
are trademarks of their respective owners. Date: 01/2017. V.01. Subject to change without notice.
Single Phase Inverters for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US
SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US OUTPUT RatedACPowerOutput 3000 3800 5000 6000 7600 VAMax.ACPowerOutput 3000 3800 5000 6000 7600 VAACOutputVoltageMin.-Nom.-Max.(183-208-229) - - 3 - - VacACOutputVoltageMin.-Nom.-Max.(211-240-264) 3 3 3 3 3 VacACFrequency(Nominal) 59.3-60-60.5(1) HzMaximumContinuousOutputCurrent208V - - 24 - - AMaximumContinuousOutputCurrent240V 12.5 16 21 25 32 AGFDIThreshold 1 AUtilityMonitoring,IslandingProtection, CountryConfigurableThresholds Yes
INPUT MaximumDCPower 4650 5900 7750 9300 11800 WTransformer-less,Ungrounded Yes MaximumInputVoltage 480 VdcNominalDCInputVoltage 380 400 Vdc MaximumInputCurrent208V - - 15.5 - - AdcMaximumInputCurrent240V 8.5 10.5 13.5 16.5 20 AdcMax.InputShortCircuitCurrent 45 AdcReverse-PolarityProtection Yes Ground-FaultIsolationDetection 600k Sensitivity MaximumInverterEfficiency 99 99.2 %CECWeightedEfficiency 99 %NighttimePowerConsumption <2.5 WSELF-SUSTAINING POWER OUTLET (OPTIONAL)NominalOutputVoltage 120 VMaximumOutputPower 1500(2) WExternalOutletwithGFDI YesADDITIONAL FEATURESSupportedCommunicationInterfaces RS485,Ethernet,ZigBee(optional),Cellular(optional)RevenueGradeData,ANSIC12.20 Optional(3)
RapidShutdown-NEC2014690.12 AutomaticRapidShutdownuponACGridDisconnectSTANDARD COMPLIANCESafety UL1741,UL1699B,CSAC22.2,CanadianAFCIaccordingtoT.I.L.M-07 GridConnectionStandards IEEE1547,Rule21,Rule14(HI) Emissions FCCPart15ClassBINSTALLATION SPECIFICATIONS ACOutputConduitSize/AWGRange 0.75-1”Conduit/14-6AWG DCInputConduitSize/#ofStrings/AWGRange 0.75-1”Conduit/1-2strings/14-6AWGDimensionswithSafetySwitch(HxWxD) 17.7x14.6x6.8/450x370x174 in/mmWeightwithSafetySwitch 25.3/11.5 lb/kgNoise <25 dBACooling NaturalConvection OperatingTemperatureRange -13to+140/-25to+60(4)(-40˚F/-40˚Coption)(5) ˚F/˚CProtectionRating NEMA3R(InverterwithSafetySwitch)
(1)ForotherregionalsettingspleasecontactSolarEdgesupport (2)DependsonPVavailability(3)RevenuegradeinverterP/N:SExxxxH-US000NNC2(4)Powerde-ratingfrom50˚C(5)-40versionP/N:SExxxxH-US000NNU4
Rapid shutdown is built-inWhat’s new in NEC 2014? NEC 2014, Section 690.12 applies to PV conductors over 10 feet from the PV array and requires that the conductors power down to 30 volts and 240 volt-amperes within 10 seconds of rapid shutdown initiation.
Enphase® Energy // Rapid Shutdown
®
To learn more, visit enphase.com
The 2014 edition of the National Electrical Code (NEC 2014) added new rapid shutdown requirements for PV systems installed on buildings. Enphase Microinverters fully meet rapid shutdown requirements in the new code without the need to install any additional electrical equipment.
Enphase comes standard with rapid shutdown capability
Residential Microinverter Commercial Microinverter
All Enphase microin-verters, even those that were previously installed, inherently meet rapid shutdown requirements, no additional equipment or workarounds needed
Enphase microinverters can safely shut down automatically, leaving only low-voltage DC electricity isolated to the PV module
String inverters require work arounds for rapid shutdown
Residential String Inverter Commercial String Inverter
Work around. Specialized Rapid Shutdown electrical box installed on the roof within 10 feet of array.
Work around. String inverter installed on roof, a hostile environment that string inverters are not built to live in.Work around.
Shutoff switch that is easily accessible to first responders on the ground.
Work around. Extra conduit in installation.
C E R T I F I C A T E O F C O M P L I A N C ECertificate Number 20161201-E341165
Report Reference E341165-20161022Issue Date 2016-DECEMBER-01
Bruce Mahrenholz, Director North American Certification Program
UL LLC
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
Page 1 of 1
ENPHASE ENERGY INCIssued to:
1420 N McDowell BlvdPetaluma CA 94954-6515
STATIC INVERTERS, CONVERTERS AND ACCESSORIES FOR USE IN INDEPENDENT POWER SYSTEMS; PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM EQUIPMENT
This is to certify thatrepresentative samples of
Permanently-Connected, Utility Interactive, Single-Phase, Split Phase, Distributed Resource Power System, Including Photovoltaic Rapid Shutdown Equipment, Models S230-60-LL-X-US, S280-60-LL-X-US.
Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate.
Standard(s) for Safety: UL 1741, Inverters, Converters, Controllers and Interconnection System Equipment for Use With Distributed Energy ResourcesCAN/CSA C22.2 No. 107.1, General Use Power Supplies
Additional Information: See the UL Online Certifications Directory atwww.ul.com/database for additional information
Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service.
Look for the UL Certification Mark on the product.
Created by UL Document Assembler 2017-01-19 15:26:04 -06:00
C E R T I F I C A T E O F C O M P L I A N C ECertificate Number 20161128-E341165
Report Reference E341165-20161108Issue Date 2016-NOVEMBER-28
Bruce Mahrenholz, Director North American Certification Program
UL LLC
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
Page 1 of 1
ENPHASE ENERGY INCIssued to:
1420 N McDowell BlvdPetaluma CA 94954-6515
STATIC INVERTERS, CONVERTERS AND ACCESSORIES FOR USE IN INDEPENDENT POWER SYSTEMS; PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM EQUIPMENT,
This is to certify thatrepresentative samples of
Permanently-connected, utility Interactive, single-phase, distributed resource power system. Series M:M Series inverters are intended for DC input from the following sources: Photovoltaic modules, ungrounded.The PV input source is Un-Grounded.The inverter is provided with transformer isolation between input and output. Models, M190, M210, M215, M250
Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate.
Standard(s) for Safety: UL 1741, Inverters, Converters, Controllers and Interconnection System Equipment for Use With Distributed Energy Resources; CSA C22.2 No. 107.1-1, General Use Power Supplies..
Additional Information: See the UL Online Certifications Directory atwww.ul.com/database for additional information
Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service.
Look for the UL Certification Mark on the product.
Created by UL Document Assembler 2016-11-29 15:35:52 -06:00