Ramveer olan seminar report for gss
description
Transcript of Ramveer olan seminar report for gss
![Page 1: Ramveer olan seminar report for gss](https://reader035.fdocuments.us/reader035/viewer/2022062702/554a48afb4c9055a408b54de/html5/thumbnails/1.jpg)
A PRACTICAL TRANING
SEMINAR
BY:-Ramveer Olan
![Page 2: Ramveer olan seminar report for gss](https://reader035.fdocuments.us/reader035/viewer/2022062702/554a48afb4c9055a408b54de/html5/thumbnails/2.jpg)
Sub-station is a subsidiary station of
an electricity generation,
transmission and distribution system
where voltage is transformed from high to
low or low to high voltage using
transformers.
![Page 3: Ramveer olan seminar report for gss](https://reader035.fdocuments.us/reader035/viewer/2022062702/554a48afb4c9055a408b54de/html5/thumbnails/3.jpg)
• Sub-station should be located at load
center
• Sufficient land area
• Grounding
• Easy of maintenance
• Possibility to Expand
• Reliability and Security
• Electrical design considerations
![Page 4: Ramveer olan seminar report for gss](https://reader035.fdocuments.us/reader035/viewer/2022062702/554a48afb4c9055a408b54de/html5/thumbnails/4.jpg)
EQUIPMENTS OF SUB STATION : • Lightning Arrester • Wave traps• Isolator• Instrument Transformers• Power Transformer• Insulator• Circuit Breaker• Power Line Carrier Communication (PLCC)
![Page 5: Ramveer olan seminar report for gss](https://reader035.fdocuments.us/reader035/viewer/2022062702/554a48afb4c9055a408b54de/html5/thumbnails/5.jpg)
• Lightning Arrester :-
To discharge lightning over voltages and
switching over voltages to earth.
![Page 6: Ramveer olan seminar report for gss](https://reader035.fdocuments.us/reader035/viewer/2022062702/554a48afb4c9055a408b54de/html5/thumbnails/6.jpg)
• Wave Trap:-To prevent high frequency signals from entering
other zones.
![Page 7: Ramveer olan seminar report for gss](https://reader035.fdocuments.us/reader035/viewer/2022062702/554a48afb4c9055a408b54de/html5/thumbnails/7.jpg)
• Isolators :-
Disconnection under no-load condition for
safety, isolation and maintenance.
![Page 8: Ramveer olan seminar report for gss](https://reader035.fdocuments.us/reader035/viewer/2022062702/554a48afb4c9055a408b54de/html5/thumbnails/8.jpg)
TYPES OF ISOLATOR•BUS ISOLATOR•LINE ISOLATOR•TRANSFORMER ISOLATING SWITCH
![Page 9: Ramveer olan seminar report for gss](https://reader035.fdocuments.us/reader035/viewer/2022062702/554a48afb4c9055a408b54de/html5/thumbnails/9.jpg)
TRANSFORMER A TRANSFORMER IS A STATIC AC DEVICE WHICH CONVERT ELECTRIC ENREGY FROM ONE FORM TO ANOTHER
1.INSTRUMENTAL TRANSFORMER CURRENT TRANSFORMER A C.T IS USED TO STEP DOWN CURRENT FOR MEASUREMENT,CONTROL AND PROTECTION
POTENTIAL TRANSFORMER A P.T IS USED TO STEP DOWN VOLTAGE FOR MEASUREMENT, CONTROL AND PROTECTION
2.POWER TRANSFORMER 1.CORE TYPE 2.SHELL TYPE
![Page 10: Ramveer olan seminar report for gss](https://reader035.fdocuments.us/reader035/viewer/2022062702/554a48afb4c9055a408b54de/html5/thumbnails/10.jpg)
• Current Transformer :-
To step-down currents for measurement,
control & protection.
![Page 11: Ramveer olan seminar report for gss](https://reader035.fdocuments.us/reader035/viewer/2022062702/554a48afb4c9055a408b54de/html5/thumbnails/11.jpg)
• Power Transformer :-To step-up or step-down the voltage
and transfer power from one a.c. voltage another a.c. voltage at the same frequency.
![Page 12: Ramveer olan seminar report for gss](https://reader035.fdocuments.us/reader035/viewer/2022062702/554a48afb4c9055a408b54de/html5/thumbnails/12.jpg)
TRANSFORMER COOLING•Natural cooling
•Oil blast cooling•Forced oil cooling•Forced air cooling
![Page 13: Ramveer olan seminar report for gss](https://reader035.fdocuments.us/reader035/viewer/2022062702/554a48afb4c9055a408b54de/html5/thumbnails/13.jpg)
TRANSFORMER USED
•There are 5 transformer are used in grid sub station1.220/132 (i) & (ii)2.132/33 (i) & (ii)3.132/11
![Page 14: Ramveer olan seminar report for gss](https://reader035.fdocuments.us/reader035/viewer/2022062702/554a48afb4c9055a408b54de/html5/thumbnails/14.jpg)
![Page 15: Ramveer olan seminar report for gss](https://reader035.fdocuments.us/reader035/viewer/2022062702/554a48afb4c9055a408b54de/html5/thumbnails/15.jpg)
• Circuit Breaker :-
Automatic switching during normal or
abnormal conditions.
![Page 16: Ramveer olan seminar report for gss](https://reader035.fdocuments.us/reader035/viewer/2022062702/554a48afb4c9055a408b54de/html5/thumbnails/16.jpg)
CIRCUIT BREAKER•Minimum oil Circuit Breaker•Air Blast Circuit Breaker•SF6 Circuit Breaker•Vacuum Circuit Breaker
![Page 17: Ramveer olan seminar report for gss](https://reader035.fdocuments.us/reader035/viewer/2022062702/554a48afb4c9055a408b54de/html5/thumbnails/17.jpg)
POWER LINE CARRIER COMMUNICATION (PLCC)•Wave trap
•Coupling Capacitor
![Page 18: Ramveer olan seminar report for gss](https://reader035.fdocuments.us/reader035/viewer/2022062702/554a48afb4c9055a408b54de/html5/thumbnails/18.jpg)
EARTHING•Neutral Earthing
•Electric Earthing
![Page 19: Ramveer olan seminar report for gss](https://reader035.fdocuments.us/reader035/viewer/2022062702/554a48afb4c9055a408b54de/html5/thumbnails/19.jpg)