A300
2
A301 1
Prep Room008
Biology 4004
Staff Office014
Fixed Seating
Biology 5005
Biology 1001
Fem P. WC015
Male P. WC016
Chemical Store009
Physics 2007
Dis.WC020
Elec Riser023
Mech riser024
Store 2021
WC Lobby017
Riser 3012
A
Covered Walkway
Entrance Lobby011
BB
A402
A402
2
Clnr St.022
B7709.5
DC E F G H J3160.5 5563.75 6250 7685 6075 24305581.25
1
2
3
4
5
6
8
7705
2232.5
1302.5
915
2482.5
2232.5
7
7429.5
Atrium010
Stair 1013
D_IN_G22
D_IN_G13 D_IN_G14D_IN_G12
D_IN_G16
D_IN_G20
D_IN_G06D_IN_G05
D_IN_G19
D_IN_G15
D_IN_G10
D_IN_G08
D_IN_G02
D_EX_G07
D_IN_G03
WG04 WG03 WG02 WG01
WG22
WG16 WG17WG15WG13WG12 WG14
WG19
WG20
WG18
WG07
WG08
WG06
Stair 2018
CW-G08
CW-G09
CW-G11
CW-G10
CW
-G03
D_IN_G24
D_IN_G25
D_IN_G23
AA
A300
WG10WG09 WG11
WPFA/TB
WPFA/TB
Biology 3003
Corridor025
By Room Name Legend
Atrium
Biology 1
Biology 2
Biology 3
Biology 4
Biology 5
Chemical Store
Clnr St.
Corridor
Dis.WC
Elec Riser
Entrance Lobby
Fem P. WC
Male P. WC
Mech riser
Physics 1
Physics 2
Prep Room
Riser
Riser 3
Room
Staff Office
Stair 1
Stair 2
Store 1
Store 2
WC Lobby
1A410
4A409
Store 1037
D_IN_G26
S_IN_G04
S_IN_G02
S_IN_G01
S_IN_G08 S_IN_G07
S_IN_G10
S_IN_G09
S_IN_G11
1
A412
Physics 1006
1A611
CW-G11
L
1
A413
D_IN_G04
S_IN_G03
D_IN_G11
D_EX_G17 D_EX_G18
D_EX_G21
Biology 2002
mobile
Fixed
S_IN_G05
D_IN_G09
450
WG23WG24WG25WG26WG27WG28WG29WG30WG05
WG31
WG32
WG33
WG34
WG35
WG36
WG37
SCALE 1:1005m0 2.5m
Scale@ A1
CheckedDrawn
Date
Status
The Old Rectory Rectory Lane Milton Malsor
N O R T H A M P T O N
t: +44 (0)1604 858916
www.peter-haddon.com
Copyright reserved. Dimensions to be checked on site.Discrepancies to be reported before proceeding.
Rev. Date/Checked
p pHarchitects
N N 7 3 A Q
f: +44 (0)1604 859123
1 : 100
PROPOSED GROUND FLOOR PLAN
Prince William SchoolProposed New Science Block
NOVEMBER 2014
mtp OCB
A200 T4
Herne Road, Oundle. Northamptonshire
4157
P1: Preliminary Issue for comment 12-14-2014
P2: Area schedules added 14-11-2014
P3: Entrance relocated, 3 labs reduced in size to 83m2 20-11-2014
P4: Re-drawn as per sketch 4157/Sk10 agreed by PWS 12-01-2015
P5: External walls revised to suit elevations 11-03-2015
P6: Revised for Stage D report 30-06-2015
P7: General Issue 28-08-2015
P8: Issue for Planning 25-09-2015
T1: TENDER ISSUE 20-10-2015
T2: AMENDED TO SUIT FIRE PLAN 11-12-2015
T3: FUME CUPBOARDS UPDATED 18-12-2015
T4: VE REISSUE FOR TENDER 01-07-2016 tw
TENDER
1 : 100
Level 00 GA 1-1001
Room Schedule 00(Ground)
Level Number Name Area Occupancy
Ground -Level 0
001 Biology 1 91.10 m²
Ground -Level 0
002 Biology 2 90.73 m² 27
Ground -Level 0
003 Biology 3 83.84 m²
Ground -Level 0
004 Biology 4 83.41 m² 27
Ground -Level 0
005 Biology 5 81.22 m² 27
Ground -Level 0
006 Physics 1 80.51 m²
Ground -Level 0
007 Physics 2 81.32 m²
Ground -Level 0
008 Prep Room 46.07 m² 27
Ground -Level 0
009 ChemicalStore
15.30 m²
Ground -Level 0
010 Atrium 36.19 m²
Ground -Level 0
011 EntranceLobby
19.14 m²
Ground -Level 0
012 Riser 3 1.10 m²
Ground -Level 0
013 Stair 1 21.82 m²
Ground -Level 0
014 Staff Office 12.45 m² 2
Ground -Level 0
015 Fem P. WC 13.70 m²
Ground -Level 0
016 Male P. WC 12.02 m²
Ground -Level 0
017 WC Lobby 13.07 m²
Ground -Level 0
018 Stair 2 23.88 m²
Ground -Level 0
020 Riser 0.58 m² -
Ground -Level 0
020 Dis.WC 4.27 m²
Ground -Level 0
021 Store 2 9.93 m²
Ground -Level 0
022 Clnr St. 2.23 m²
Ground -Level 0
023 Elec Riser 2.18 m²
Ground -Level 0
024 Mech riser 2.30 m²
Ground -Level 0
025 Corridor 118.08 m²
Ground -Level 0
037 Store 1 4.88 m²
Ground -Level 0
059 Chemistry 2 NotEnclosed
Ground -Level 0
060 Atrium NotEnclosed
Ground -Level 0
070 Room NotEnclosed
Grand total: 29 951.31 m²
• For detail setting out information seedrawing 4157_A230
• Refer to Room Data sheets for detailfurniture information
• For Window Schedule & Details seedrawings 4157_A605 & 4157_A606
• For Internal Door Schedule & details seedrawing 4157_A607
• For Floor Finishes Plan see drawing4157_A613
Below ground drainage run to beconfirmed by M&E allow connection forTeachers desk & island unit
All Gas, water & electrical feeds to theseareas to be concealed & in accordancewith M&E design & specification
A300
2
A301 1
Chemistry 2102
Chemistry 3103
Chemistry 4104
DisabledRefuge
Line of Canopy/shelter below
Chemistry 1101
Prep Room108
Fem P. WC118
Male P. WC119
Chem. St.109
Server115
St. WC116
St. WC117
Dis
able
dR
efu
ge
Riser 3111
Dis. WC122
Team Base114
WC Lobby120
Balcony/Circulation110
Elec Riser124
A
Mech Riser125
Void over Atrium(rooflights above)
Store 3112
Stair 1113
BB
A402
A402
2
B DC E F G H J
1
2
3
4
5
6
8
7
7709.5 3160.5 5563.75 6250 7685 6075 24305581.25
7705
2232.5
1302.5
915
2482.5
2232.5
7429.5
Chemistry 5105
Physics 3106
Physics 4107
D_IN_F01D_IN_F15
D_IN_F19 D_IN_F18
D_IN_F09
D_IN_F20
D_IN_F04
D_IN_F05
D_IN_F10 D_IN_F11
D_IN_F12
D_IN_F21D_IN_F13
D_IN_F14
Clnr. St.123
Stair 2121
WF03 WF02WF04 WF01
WF25WF23WF22WF21WF20WF19WF18WF16
WF13
WF11
WF10
WF09
WF06
WF05
WF24WF17
WF14
WF28
WF27
CW-G03
CW-G09CW-G08 CW-G10
CW-G11
AA
A300
WF26WF15
WF12
WF08
WF07
WF29
D_IN_F22
WP TBwith AAV
By Room Name Legend
Balcony/Circulation
Chem. St.
Chemistry 1
Chemistry 2
Chemistry 3
Chemistry 4
Chemistry 5
Clnr. St.
Dis. WC
Elec Riser
Fem P. WC
Male P. WC
Mech Riser
Physics 3
Physics 4
Prep Room
Riser 3
Server
St. WC
Stair 1
Stair 2
Store 3
Team Base
WC Lobby
2A410
5A409
1
A412
2A611
CW-F03
CW-F04
L
1
A413
D_IN_F06
D_IN_F03
D_IN_F02
D_IN_F17 D_IN_F16
D_IN_F08
Flue FB TA
FIX
ED
FIXED
FIXED
FIX
ED
FIXED
FIX
ED
WF30WF31WF32WF33WF34WF35WF36WF37WF38WF39WF40
SCALE 1:1005m0 2.5m
Scale@ A1
CheckedDrawn
Date
Status
The Old Rectory Rectory Lane Milton Malsor
N O R T H A M P T O N
t: +44 (0)1604 858916
www.peter-haddon.com
Copyright reserved. Dimensions to be checked on site.Discrepancies to be reported before proceeding.
Rev. Date/Checked
p pHarchitects
N N 7 3 A Q
f: +44 (0)1604 859123
1 : 100
PROPOSED FIRST FLOOR PLAN
Prince William SchoolProposed New Science Block
NOVEMBER 2014
mtp ocb
A201 T4
Herne Road, Oundle. Northamptonshire
4157
P1: Preliminary Issue for Comment 12-14-2014
P2: Area Schedule added 14-11-2014
P3: Labs reduced to 83m2, ICT Room & Fixed seating added 20-11-2014
P4: Rooflights indicated for clarity 28-11-2014
P5: Re-drawn as per sketch 4157/Sk11 approved by PWS 12-01-2015
P6: External walls revised to suit elevations 11-03-2015
P7: Revised for stage D report 30-06-2015
P8: General Issue 28-08-2015
P9: Issue for Planning 25-09-2015
T1: TENDER ISSUE 20-10-2015
T2: AMENDED TO SUIT FIRE PLAN 11-12-2015
T3: FUME CUPBOARDS AMENDED 18-12-2015
T4: VE REISSUE FOR TENDER 04-07-2016
TENDER 1 : 100
Level 01 GA 1-1001
Room Schedule 01(First)
Level Number Name Area Occupancy
First - Level1
101 Chemistry 1 109.84 m²
First - Level1
102 Chemistry 2 90.78 m² 27
First - Level1
103 Chemistry 3 83.64 m² 27
First - Level1
104 Chemistry 4 83.77 m² 27
First - Level1
105 Chemistry 5 81.07 m²
First - Level1
106 Physics 3 80.05 m²
First - Level1
107 Physics 4 81.32 m²
First - Level1
108 Prep Room 46.02 m²
First - Level1
109 Chem. St. 15.29 m²
First - Level1
110 Balcony/Circulation
117.56 m²
First - Level1
111 Riser 3 1.10 m²
First - Level1
112 Store 3 1.18 m²
First - Level1
113 Stair 1 26.50 m²
First - Level1
114 Team Base RedundantRoom
First - Level1
115 Server 5.84 m²
First - Level1
116 St. WC 2.24 m²
First - Level1
117 St. WC 2.23 m²
First - Level1
118 Fem P. WC 13.55 m²
First - Level1
119 Male P. WC 11.85 m²
First - Level1
120 WC Lobby 13.07 m²
First - Level1
121 Stair 2 17.79 m²
First - Level1
122 Dis. WC 4.58 m²
First - Level1
123 Clnr. St. 2.23 m²
First - Level1
124 Elec Riser 2.18 m²
First - Level1
125 Mech Riser 2.27 m²
Grand total: 25 895.94 m²
• For detail setting out information see drawing4157_A231
• Refer to Room Data sheets for detail furnitureinformation
• For Window Schedule & Details see drawings 4157_A605& 4157_A606
• For Internal Door Schedule & details see drawing 4157_A607
• For Floor Finishes Plan see drawing4157_A614
All Gas, water & electrical feeds to these areas to beconcealed & in accordance with M&E design &specification
A300
2
A301 1Lanternlight rooflight to bring lightdeep into plan depth. Single plymembrane roof finish NBS J42
Green Roof - Sedum Planting
MaintenanceAccess
LiftOverrun
Paving for Access
Photovoltaic (PV) Panels
Full Height 1100mm high tubularBalustrade with horizontalmidrail to entire perimeter tosatisfy CDM requirements &provide full access formaintenance NBS L30/560
A
RoofLight
RoofLight
BB
A402
A402
2
B DC E F G H J
1
2
3
4
5
6
8
7
Vent TA
Vent TA
Vent TA
L02
Stair 2204
D_E
X_S
02
D_IN_S01
AA
A300
Store 4205
665
1810
450
Plant Room202
L01
D_EX_S03
Condenser Compound with1.6m high levolux LX louvreson metsec/steel frame NBSL10/505 (see drawing A502)
Vent pipeFB/TA
3A410
37775 FFL
37775 FFL
37980FFL
37980FFL
Gate
Gate
Polyester powdercoated folded metalcapping RAL 7015
RWO RWORWO
RWO
RWO RWO RWO RWO
1
A412
CW-S01
L
1
A413
1
A420
Flue
Flue
Flue
Flu
eFlue
RoofLight
RoofLight
RoofLight
RoofLight
RoofLight
RoofLight
RoofLight
2 deg Fall
2 deg Fall
2� Fall
2 deg Fall
2 deg Fall
2 deg Fall
2 deg Fall
2 deg Fall
2 deg Fall
2 deg Fall
2� Fall
All rooflights to have insulated upstand as drawing4157/A420. Rooflights installed inline with DVS(Daylight & Ventilation Solutions Ltd) requirements& specification, with Polyester powder coatedaluminium flashing to match roof light RAL 7015.2No. Rooflight total. Ref: 1200 x 1200 Lamilux FE3polyester Powder Coated aluminium rooflight toacheive 1.5 'U' value NBS L10/500
37980FFL
Top of brick parapet 9225Above foundation level pluscaping to allow 150mm min.above sedum blanket &ballast
37882 FFL
37882 FFL
ROOF FINISHES LEGENDNBS J31, J42, Q37
Pattern Description
Fin
ish la
yer
depth
Substr
ate
depth
Roof finish & accessories by Bauder. To be installed by approved contractor in linewith Bauder's specification & installation requirements
All roof coverings to acheive 0.16 'U' Value
Allow insulated upstand to all parapets & wall abutments
Dra
inage
depth
insula
tion
deoth
Overa
ll ro
of
finis
h d
epth
Bauder Sedum Green roof covering onbauderflex green systemNBS J41/110 & Q37/130
48 10 20 140 218
Paving slabs to form access routeproprietary pedestal support system NBSQ37/841A on buaderflex green systemNBS J41/110
50 10 20 140 218
ballast to perimeter edges on Bauderflexgreen systemNBS Q37/460 & 840
50 10 20 140 218
Single ply roof membrane to Atrium roof &plant room roof area NBS J42/110 1.5 140 150
SCALE 1:1005m0 2.5m
Scale@ A1
CheckedDrawn
Date
Status
The Old Rectory Rectory Lane Milton Malsor
N O R T H A M P T O N
t: +44 (0)1604 858916
www.peter-haddon.com
Copyright reserved. Dimensions to be checked on site.Discrepancies to be reported before proceeding.
Rev. Date/Checked
p pHarchitects
N N 7 3 A Q
f: +44 (0)1604 859123
1 : 100
PROPOSED ROOF ACCESS LEVEL
Prince William SchoolProposed New Science Block
NOVEMBER 2014
mtp ocb
A202 T3
Herne Road, Oundle. Northamptonshire
4157
P1: Preliminary Issue for comment 12-11-2014
P2: Area schedule added 14-11-2014
P3: Footprint of building reduced to fit survey of electric cable 20-11-2014
P4:Notes amended as per PWS comments, rooflightsclarified
28-11-2014
P5: Re-drawn as sketches 4157/Sk10&SK11 agreed by PWS 12-01-2015
P6: Roof revised to suit elevations 11-03-2015
P7: Balustrade & rooflights amended 17-06-2015
P8: Roof build up amended to suit Bauder details 19-06-2015
P9: Revised for Stage D report 30-06-2015
P10: Plant room amended 28-08-2015
P11: Plant room north louvre removed 09-09-2015
P12: Issue for Planning 25-09-2015
T1: TENDER ISSUE 20-10-2015
T2: FUME CUPBOARD FLUES INDICATED 18-12-2015
T3: VE REISSUE FOR TENDER 04-07-2016
TENDER 1 : 100
Level 02 GA(Roof Access)1-1001
A300
2
A301 1
A402
2
Vent TA
Vent cowel
Ventcowel
Bauder rainwateroutlet cover with flatroof outlet belowinstalled in line withmanufacturers detailsNBS J31/343
RWP with shoe
Lift over run
Polyester powdercoated folded metalcapping RAL 7015
Polyester powdercoated folded metalcapping RAL 7015NBS H72/421
Polyester powder coatedinternally galvanised metalgutters & downpipes
RWO RWORWO
RWO
RWO RWO RWO
RWO
38065FFL
40650 FRL
All rooflights to have insulated upstand asdrawing 4157/A420. Rooflights installed inlinewith DVS (Daylight & Ventilation Solutions Ltd)requirements & specification, with Polyesterpowder coated aluminium flashing to matchroof light RAL 7015. 2No. Rooflight total. Ref:1200 x 1200 Lamilux FE3 polyester PowderCoated aluminium rooflight to acheive 1.5 'U'value NBS L10/500
41930 FRL
To fall
1 in 4
0
To fall
1 in 4
0
To fall 1 in 80
Integral gutter withdownpipe withincolumn to separatedetail
KME Tecu Gold metalsheet horizontal Brisesoliel sun shading NBSH73/140
Rain water outlet
To fall 1 in 80
Gate
1.6m high Louvred screento form services compoundNBS L10/505 refer drawing4157/A502
Single ply roof membrane on130mm insulation on VCL, on18mm marine grade ply on furringon timber joists to provide 1 in 40fall. To achieve 0.16 U value, nbsJ42/110
Single ply roof membrane on 130mminsulation on VCL, on 18mm marinegrade ply on furring on timber joiststo provide 1 in 40 fall. To achieve0.16 U value
KME Tecu Gold metalsheet roof cladding withstanding seam NBSH73/110
Fume cubd.flue (fanposition tbc)
Fume cubd.flue (fanposition tbc)
Fume cuboardflues (fanpositions tbc)
RL03RL02
RL01
RL09RL08RL07
RL06
RL05
RL04
37980FFL
37980FFL
37980FFL
Top of brick parapet 9225Above foundation level pluscaping to allow 150mm min.above sedum blanket &ballast
ROOF FINISHES LEGENDNBS J31, J42, Q37
Pattern Description
Fin
ish la
yer
depth
Substr
ate
depth
Roof finish & accessories by Bauder. To be installed by approved contractor in linewith Bauder's specification & installation requirements
All roof coverings to acheive 0.16 'U' Value
Allow insulated upstand to all parapets & wall abutments
Dra
inage
depth
insula
tion
deoth
Overa
ll ro
of
finis
h d
epth
Bauder Sedum Green roof covering onbauderflex green systemNBS J41/110 & Q37/130
48 10 20 140 218
Paving slabs to form access routeproprietary pedestal support system NBSQ37/841A on buaderflex green systemNBS J41/110
50 10 20 140 218
ballast to perimeter edges on Bauderflexgreen systemNBS Q37/460 & 840
50 10 20 140 218
Single ply roof membrane to Atrium roof &plant room roof area NBS J42/110 1.5 140 150
SCALE 1:1005m0 2.5m
Scale@ A1
CheckedDrawn
Date
Status
The Old Rectory Rectory Lane Milton Malsor
N O R T H A M P T O N
t: +44 (0)1604 858916
www.peter-haddon.com
Copyright reserved. Dimensions to be checked on site.Discrepancies to be reported before proceeding.
Rev. Date/Checked
p pHarchitects
N N 7 3 A Q
f: +44 (0)1604 859123
1 : 100
PROPOSED ROOF PLAN
Prince William SchoolProposed New Science Block
JULY 2015
tw Checker
A222 T3
Herne Road, Oundle. Northamptonshire
4157
P1: Roof Finishes updated 28-08-2015
P2: Roof fall revised 09-09-2015
P3: Issue for Planning 25-09-2015
P4: Plant & atrium roof notes amended 09-10-2015
T1: TENDER ISSUE 20-10-2015
T2: FUME CUPBOARD FLUES INDICATED 18-12-2015
T3: VE REISSUE FOR TENDER 04-07-2016
TENDER
1 : 100
Roof Plan - 1-1001
29
22
6
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Issue Purpose:
Rev Date/Checked
pHppHp a r c h i t e c t s
Drawn by: Checked by:
Scale @ A1: Date:
CAD ref: Dwg no.: Rev:
Expansion & Re-organisation of Prince William SchoolNorthamptonshire County CouncilHerne Road, Oundle, Northants
Site - Proposed Constraints Plan Phase 2
TENDER ISSUEmtp ocb
1:500 November 2014
PWS01 4157/05 T3
P1: First Issue 26.05.15 JBP2: Amended to exclude phase 3 28.05.15 JBP3: Sports area included in Phase 2. Compound reduced to suit modular village 07-07-15 mtpP4: compound updated to suit asbestos removal. Noted added re:HV cable 24-09-15 mtpP5: Application area amended to omit block D0 25-09-15 mtpT1: TENDER ISSUE 22-10-15 mtpT2: VE Re-issue for Tender 04-07-16 mtpT3: Mobile removed, note re:gas main re-location removed for Tender 05-07-16 mtp
N
SCALE 1:50020m0 10m
Overhanging trees cut back& provide protection.
BT
AW (Foul Sewer)
HV Cables (WPD)
Gas
AW (Water)
Contractor vehicle access note:Contractor to use same main access as school during term timeno access will be allowed during following times:-08:15 - 09:3014:30 - 15:45See PCIP for further details.
Phase 2 works area, includes contractor compound/ storage area / parking / building access.
Protected Trees & Rootprotection zone.
NOTE: Fire access toschool buildings requiredthroughout project.
Cadets
Nursery
Access required toCadets / Nursery forduration of works
S L O P E
S L O P E
Gas housing
AW - PumpingStation
Possible line ofcontractor fencing.
For full details of all existingservices see utilities plansand sub-technics surveydrawing 10703_UGI-0
Gas main
Main Sewer
Remove 2x trees (T4 & T5).
Protect existing Ash treebeing retained (T3).
Access for students toremain clear.
School parkingavailable outside ofbuilding works area.
ContractorParking.
Main contractor
compound.
Modular Village
Design Technology
A0
English & Modernforeign languages
X0
C0
D0
Library
Admin
F0Sports Hall & Changing
E0
T0Science
DanceStudio
Y0Fitness,Sports &Changing
Science Block
Caretakers
Gas & Water(not on survey)
gates/crossover
Note: Contractor to surveyexact position of HV electriccable and mark-out on siteprior to any excavation in thisarea.Protect Neighbours
Tree (T2).
6
7
8
9
1
0
Temporary Buildings
(landscaping to be completed
on removal of temporary
buildings)
New Science
Block
DN
UP
UP
Chemistry 2
002
Prep Room
008
Chemistry 4
004
Staff Office
014
Fixed Seating
Chemistry 5
005
Chemistry 1
001
Fem P. WC
015
Male P. WC
016
Chemical Store
009
Physics 2
007
Dis.WC
020
Elec Riser
023
Mech riser
024
Store 2
021
WC Lobby
017
Riser 3
012
Covered Walkway
Entrance Lobby
011
Clnr St.
022
Atrium
010
Stair 1
013
Stair 2
018
WP
FA/TB
Chemistry 3
003
Corridor
025
Store 1
037
Physics 1
006
P +2
9.78
P +29.66
P +29.675
P +29.160
P +29.66
1 in 21 gradual slope - ground graded to suitPermeable Tarmac finish
Turfed ground to suit side pathgradient
1 in 2
1 gra
dient
P +29.66
Existing banked ground - grass
Bank
ed gr
ound
- gra
ss
E +29.99
E +29.52
P +29.52
Line of notional turning head for emergencyaccess (no demarcation required) New Tarmac footpath
New
Tarm
ac pa
th
New tarmac path to suit existing &proposed level differences, allowflush concrete edge to line of newpath. NBS Q22
New
Tarm
ac fo
otpath
Remove fencingRemove retaining wall &associated footings
Break out concrete slab& lay new tarmac finish
REIN
STAT
E TA
RMAC
PLA
Y AR
EAON
REM
OVAL
OF
TEMP
ORAR
YBU
ILDIN
GS
Exitin
g Tar
mac f
ootpa
th re
taine
d
New
Tarm
ac fo
otpath
Ground regraded to suit
Ground regraded to suit
Existing Levelsretained - groundreturfed
Remove gateRemove gates
New
Tarm
ac fo
otpath
New 2.2m palisade fencing
New Tarmac footpath
NB. All new tarmac to be permeable.Entire courtyard area to be capableof withstanding emergency firevehicle loading. Sub base to S.E'sdesign & specification NBS Q22
Remove concrete kerb &make good junctionRemove lines for 1No.parking space
Grass
Gravel perimeter to sit150mm below DPC
E +29.11
Yellow thermoplasticcross hatching todemark no parking area
P +30.54
up
Existing 2.2m palisade fencing
Issue Purpose:
Rev Date/Checked
pHppHp a r c h i t e c t s
Drawn by: Checked by:
Scale @ A1: Date:
CAD ref: Dwg no.: Rev:
Expansion & Re-organisation of Prince William SchoolNorthamptonshire County CouncilHerne Road, Oundle, Northants
Science Landscape Strategy Plan
TENDERmtp ocb
1:200 September 2015
PWS219 4157/238 T2
P1: Issued for Planning 25-15-09 mtpT1: TENDER ISSUE 20-10-15 twT2: VE Science Block Tender Issue 08-07-16 mtp
N
SCALE 1:50020m0 10m
NEW RED PERMEABLE TARMAC FINISH FLUSH WITH FOOTPATH. SUB BASE SUITABLE FOR EMERGENCYVEHICLE LOADING TO S.E DESIGN & SPECIFICATION
NEW BLACK PERMEABLE TARMAC FINISH FLUSH WITH ROAD. SUB BASE SUITABLE FOR EMERGENCYVEHICLE LOADING TO S.E DESIGN & SPECIFICATION
NEW BLACK PERMEABLE TARMAC FINISH SUB BASE TO S.E DESIGN & SPECIFICATION
NOTEALL MANHOLE COVERS TO BE ADJUSTED TO SUIT NEW LEVELS
NBS Q22
NBS Q22
NBS Q22