R:4100-41994157 Prince William Secondary4157 C pHp ... · Elec Riser Entrance Lobby Fem P. WC Male...

6
A300 2 A301 1 Prep Room 008 Biology 4 004 Staff Office 014 Fixed Seating Biology 5 005 Biology 1 001 Fem P. WC 015 Male P. WC 016 Chemical Store 009 Physics 2 007 Dis.WC 020 Elec Riser 023 Mech riser 024 Store 2 021 WC Lobby 017 Riser 3 012 A Covered Walkway Entrance Lobby 011 BB A402 A402 2 Clnr St. 022 B 7709.5 D C E F G H J 3160.5 5563.75 6250 7685 6075 2430 5581.25 1 2 3 4 5 6 8 7705 2232.5 1302.5 915 2482.5 2232.5 7 7429.5 Atrium 010 Stair 1 013 D_IN_G22 D_IN_G13 D_IN_G14 D_IN_G12 D_IN_G16 D_IN_G20 D_IN_G06 D_IN_G05 D_IN_G19 D_IN_G15 D_IN_G10 D_IN_G08 D_IN_G02 D_EX_G07 D_IN_G03 WG04 WG03 WG02 WG01 WG22 WG16 WG17 WG15 WG13 WG12 WG14 WG19 WG20 WG18 WG07 WG08 WG06 Stair 2 018 CW-G08 CW-G09 CW-G11 CW-G10 CW-G03 D_IN_G24 D_IN_G25 D_IN_G23 AA A300 WG10 WG09 WG11 WP FA/TB WP FA/TB Biology 3 003 Corridor 025 By Room Name Legend Atrium Biology 1 Biology 2 Biology 3 Biology 4 Biology 5 Chemical Store Clnr St. Corridor Dis.WC Elec Riser Entrance Lobby Fem P. WC Male P. WC Mech riser Physics 1 Physics 2 Prep Room Riser Riser 3 Room Staff Office Stair 1 Stair 2 Store 1 Store 2 WC Lobby 1 A410 4 A409 Store 1 037 D_IN_G26 S_IN_G04 S_IN_G02 S_IN_G01 S_IN_G08 S_IN_G07 S_IN_G10 S_IN_G09 S_IN_G11 1 A412 Physics 1 006 1 A611 CW-G11 L 1 A413 D_IN_G04 S_IN_G03 D_IN_G11 D_EX_G17 D_EX_G18 D_EX_G21 Biology 2 002 mobile Fixed S_IN_G05 D_IN_G09 450 WG23 WG24 WG25 WG26 WG27 WG28 WG29 WG30 WG05 WG31 WG32 WG33 WG34 WG35 WG36 WG37 SCALE 1:100 5m 0 2.5m Scale@ A1 Checked Drawn Date Status The Old Rectory Rectory Lane Milton Malsor N O R T H A M P T O N t: +44 (0)1604 858916 www.peter-haddon.com Copyright reserved. Dimensions to be checked on site. Discrepancies to be reported before proceeding. Rev. Date/Checked p p H architects N N 7 3 A Q f: +44 (0)1604 859123 1 : 100 PROPOSED GROUND FLOOR PLAN Prince William School Proposed New Science Block NOVEMBER 2014 mtp OCB A200 T4 Herne Road, Oundle. Northamptonshire 4157 P1: Preliminary Issue for comment 12-14-2014 P2: Area schedules added 14-11-2014 P3: Entrance relocated, 3 labs reduced in size to 83m2 20-11-2014 P4: Re-drawn as per sketch 4157/Sk10 agreed by PWS 12-01-2015 P5: External walls revised to suit elevations 11-03-2015 P6: Revised for Stage D report 30-06-2015 P7: General Issue 28-08-2015 P8: Issue for Planning 25-09-2015 T1: TENDER ISSUE 20-10-2015 T2: AMENDED TO SUIT FIRE PLAN 11-12-2015 T3: FUME CUPBOARDS UPDATED 18-12-2015 T4: VE REISSUE FOR TENDER 01-07-2016 tw TENDER 1 : 100 Level 00 GA 1-100 1 Room Schedule 00(Ground) Level Number Name Area Occupancy Ground - Level 0 001 Biology 1 91.10 m² Ground - Level 0 002 Biology 2 90.73 m² 27 Ground - Level 0 003 Biology 3 83.84 m² Ground - Level 0 004 Biology 4 83.41 m² 27 Ground - Level 0 005 Biology 5 81.22 m² 27 Ground - Level 0 006 Physics 1 80.51 m² Ground - Level 0 007 Physics 2 81.32 m² Ground - Level 0 008 Prep Room 46.07 m² 27 Ground - Level 0 009 Chemical Store 15.30 m² Ground - Level 0 010 Atrium 36.19 m² Ground - Level 0 011 Entrance Lobby 19.14 m² Ground - Level 0 012 Riser 3 1.10 m² Ground - Level 0 013 Stair 1 21.82 m² Ground - Level 0 014 Staff Office 12.45 m² 2 Ground - Level 0 015 Fem P. WC 13.70 m² Ground - Level 0 016 Male P. WC 12.02 m² Ground - Level 0 017 WC Lobby 13.07 m² Ground - Level 0 018 Stair 2 23.88 m² Ground - Level 0 020 Riser 0.58 m² - Ground - Level 0 020 Dis.WC 4.27 m² Ground - Level 0 021 Store 2 9.93 m² Ground - Level 0 022 Clnr St. 2.23 m² Ground - Level 0 023 Elec Riser 2.18 m² Ground - Level 0 024 Mech riser 2.30 m² Ground - Level 0 025 Corridor 118.08 m² Ground - Level 0 037 Store 1 4.88 m² Ground - Level 0 059 Chemistry 2 Not Enclosed Ground - Level 0 060 Atrium Not Enclosed Ground - Level 0 070 Room Not Enclosed Grand total: 29 951.31 m² For detail setting out information see drawing 4157_A230 Refer to Room Data sheets for detail furniture information For Window Schedule & Details see drawings 4157_A605 & 4157_A606 For Internal Door Schedule & details see drawing 4157_A607 For Floor Finishes Plan see drawing 4157_A613 Below ground drainage run to be confirmed by M&E allow connection for Teachers desk & island unit All Gas, water & electrical feeds to these areas to be concealed & in accordance with M&E design & specification

Transcript of R:4100-41994157 Prince William Secondary4157 C pHp ... · Elec Riser Entrance Lobby Fem P. WC Male...

Page 1: R:4100-41994157 Prince William Secondary4157 C pHp ... · Elec Riser Entrance Lobby Fem P. WC Male P. WC Mech riser Physics 1 Physics 2 Prep Room Riser Riser 3 Room Staff Office Stair

A300

2

A301 1

Prep Room008

Biology 4004

Staff Office014

Fixed Seating

Biology 5005

Biology 1001

Fem P. WC015

Male P. WC016

Chemical Store009

Physics 2007

Dis.WC020

Elec Riser023

Mech riser024

Store 2021

WC Lobby017

Riser 3012

A

Covered Walkway

Entrance Lobby011

BB

A402

A402

2

Clnr St.022

B7709.5

DC E F G H J3160.5 5563.75 6250 7685 6075 24305581.25

1

2

3

4

5

6

8

7705

2232.5

1302.5

915

2482.5

2232.5

7

7429.5

Atrium010

Stair 1013

D_IN_G22

D_IN_G13 D_IN_G14D_IN_G12

D_IN_G16

D_IN_G20

D_IN_G06D_IN_G05

D_IN_G19

D_IN_G15

D_IN_G10

D_IN_G08

D_IN_G02

D_EX_G07

D_IN_G03

WG04 WG03 WG02 WG01

WG22

WG16 WG17WG15WG13WG12 WG14

WG19

WG20

WG18

WG07

WG08

WG06

Stair 2018

CW-G08

CW-G09

CW-G11

CW-G10

CW

-G03

D_IN_G24

D_IN_G25

D_IN_G23

AA

A300

WG10WG09 WG11

WPFA/TB

WPFA/TB

Biology 3003

Corridor025

By Room Name Legend

Atrium

Biology 1

Biology 2

Biology 3

Biology 4

Biology 5

Chemical Store

Clnr St.

Corridor

Dis.WC

Elec Riser

Entrance Lobby

Fem P. WC

Male P. WC

Mech riser

Physics 1

Physics 2

Prep Room

Riser

Riser 3

Room

Staff Office

Stair 1

Stair 2

Store 1

Store 2

WC Lobby

1A410

4A409

Store 1037

D_IN_G26

S_IN_G04

S_IN_G02

S_IN_G01

S_IN_G08 S_IN_G07

S_IN_G10

S_IN_G09

S_IN_G11

1

A412

Physics 1006

1A611

CW-G11

L

1

A413

D_IN_G04

S_IN_G03

D_IN_G11

D_EX_G17 D_EX_G18

D_EX_G21

Biology 2002

mobile

Fixed

S_IN_G05

D_IN_G09

450

WG23WG24WG25WG26WG27WG28WG29WG30WG05

WG31

WG32

WG33

WG34

WG35

WG36

WG37

SCALE 1:1005m0 2.5m

Scale@ A1

CheckedDrawn

Date

Status

The Old Rectory Rectory Lane Milton Malsor

N O R T H A M P T O N

t: +44 (0)1604 858916

www.peter-haddon.com

Copyright reserved. Dimensions to be checked on site.Discrepancies to be reported before proceeding.

Rev. Date/Checked

p pHarchitects

N N 7 3 A Q

f: +44 (0)1604 859123

1 : 100

PROPOSED GROUND FLOOR PLAN

Prince William SchoolProposed New Science Block

NOVEMBER 2014

mtp OCB

A200 T4

Herne Road, Oundle. Northamptonshire

4157

P1: Preliminary Issue for comment 12-14-2014

P2: Area schedules added 14-11-2014

P3: Entrance relocated, 3 labs reduced in size to 83m2 20-11-2014

P4: Re-drawn as per sketch 4157/Sk10 agreed by PWS 12-01-2015

P5: External walls revised to suit elevations 11-03-2015

P6: Revised for Stage D report 30-06-2015

P7: General Issue 28-08-2015

P8: Issue for Planning 25-09-2015

T1: TENDER ISSUE 20-10-2015

T2: AMENDED TO SUIT FIRE PLAN 11-12-2015

T3: FUME CUPBOARDS UPDATED 18-12-2015

T4: VE REISSUE FOR TENDER 01-07-2016 tw

TENDER

1 : 100

Level 00 GA 1-1001

Room Schedule 00(Ground)

Level Number Name Area Occupancy

Ground -Level 0

001 Biology 1 91.10 m²

Ground -Level 0

002 Biology 2 90.73 m² 27

Ground -Level 0

003 Biology 3 83.84 m²

Ground -Level 0

004 Biology 4 83.41 m² 27

Ground -Level 0

005 Biology 5 81.22 m² 27

Ground -Level 0

006 Physics 1 80.51 m²

Ground -Level 0

007 Physics 2 81.32 m²

Ground -Level 0

008 Prep Room 46.07 m² 27

Ground -Level 0

009 ChemicalStore

15.30 m²

Ground -Level 0

010 Atrium 36.19 m²

Ground -Level 0

011 EntranceLobby

19.14 m²

Ground -Level 0

012 Riser 3 1.10 m²

Ground -Level 0

013 Stair 1 21.82 m²

Ground -Level 0

014 Staff Office 12.45 m² 2

Ground -Level 0

015 Fem P. WC 13.70 m²

Ground -Level 0

016 Male P. WC 12.02 m²

Ground -Level 0

017 WC Lobby 13.07 m²

Ground -Level 0

018 Stair 2 23.88 m²

Ground -Level 0

020 Riser 0.58 m² -

Ground -Level 0

020 Dis.WC 4.27 m²

Ground -Level 0

021 Store 2 9.93 m²

Ground -Level 0

022 Clnr St. 2.23 m²

Ground -Level 0

023 Elec Riser 2.18 m²

Ground -Level 0

024 Mech riser 2.30 m²

Ground -Level 0

025 Corridor 118.08 m²

Ground -Level 0

037 Store 1 4.88 m²

Ground -Level 0

059 Chemistry 2 NotEnclosed

Ground -Level 0

060 Atrium NotEnclosed

Ground -Level 0

070 Room NotEnclosed

Grand total: 29 951.31 m²

• For detail setting out information seedrawing 4157_A230

• Refer to Room Data sheets for detailfurniture information

• For Window Schedule & Details seedrawings 4157_A605 & 4157_A606

• For Internal Door Schedule & details seedrawing 4157_A607

• For Floor Finishes Plan see drawing4157_A613

Below ground drainage run to beconfirmed by M&E allow connection forTeachers desk & island unit

All Gas, water & electrical feeds to theseareas to be concealed & in accordancewith M&E design & specification

Page 2: R:4100-41994157 Prince William Secondary4157 C pHp ... · Elec Riser Entrance Lobby Fem P. WC Male P. WC Mech riser Physics 1 Physics 2 Prep Room Riser Riser 3 Room Staff Office Stair

A300

2

A301 1

Chemistry 2102

Chemistry 3103

Chemistry 4104

DisabledRefuge

Line of Canopy/shelter below

Chemistry 1101

Prep Room108

Fem P. WC118

Male P. WC119

Chem. St.109

Server115

St. WC116

St. WC117

Dis

able

dR

efu

ge

Riser 3111

Dis. WC122

Team Base114

WC Lobby120

Balcony/Circulation110

Elec Riser124

A

Mech Riser125

Void over Atrium(rooflights above)

Store 3112

Stair 1113

BB

A402

A402

2

B DC E F G H J

1

2

3

4

5

6

8

7

7709.5 3160.5 5563.75 6250 7685 6075 24305581.25

7705

2232.5

1302.5

915

2482.5

2232.5

7429.5

Chemistry 5105

Physics 3106

Physics 4107

D_IN_F01D_IN_F15

D_IN_F19 D_IN_F18

D_IN_F09

D_IN_F20

D_IN_F04

D_IN_F05

D_IN_F10 D_IN_F11

D_IN_F12

D_IN_F21D_IN_F13

D_IN_F14

Clnr. St.123

Stair 2121

WF03 WF02WF04 WF01

WF25WF23WF22WF21WF20WF19WF18WF16

WF13

WF11

WF10

WF09

WF06

WF05

WF24WF17

WF14

WF28

WF27

CW-G03

CW-G09CW-G08 CW-G10

CW-G11

AA

A300

WF26WF15

WF12

WF08

WF07

WF29

D_IN_F22

WP TBwith AAV

By Room Name Legend

Balcony/Circulation

Chem. St.

Chemistry 1

Chemistry 2

Chemistry 3

Chemistry 4

Chemistry 5

Clnr. St.

Dis. WC

Elec Riser

Fem P. WC

Male P. WC

Mech Riser

Physics 3

Physics 4

Prep Room

Riser 3

Server

St. WC

Stair 1

Stair 2

Store 3

Team Base

WC Lobby

2A410

5A409

1

A412

2A611

CW-F03

CW-F04

L

1

A413

D_IN_F06

D_IN_F03

D_IN_F02

D_IN_F17 D_IN_F16

D_IN_F08

Flue FB TA

FIX

ED

FIXED

FIXED

FIX

ED

FIXED

FIX

ED

WF30WF31WF32WF33WF34WF35WF36WF37WF38WF39WF40

SCALE 1:1005m0 2.5m

Scale@ A1

CheckedDrawn

Date

Status

The Old Rectory Rectory Lane Milton Malsor

N O R T H A M P T O N

t: +44 (0)1604 858916

www.peter-haddon.com

Copyright reserved. Dimensions to be checked on site.Discrepancies to be reported before proceeding.

Rev. Date/Checked

p pHarchitects

N N 7 3 A Q

f: +44 (0)1604 859123

1 : 100

PROPOSED FIRST FLOOR PLAN

Prince William SchoolProposed New Science Block

NOVEMBER 2014

mtp ocb

A201 T4

Herne Road, Oundle. Northamptonshire

4157

P1: Preliminary Issue for Comment 12-14-2014

P2: Area Schedule added 14-11-2014

P3: Labs reduced to 83m2, ICT Room & Fixed seating added 20-11-2014

P4: Rooflights indicated for clarity 28-11-2014

P5: Re-drawn as per sketch 4157/Sk11 approved by PWS 12-01-2015

P6: External walls revised to suit elevations 11-03-2015

P7: Revised for stage D report 30-06-2015

P8: General Issue 28-08-2015

P9: Issue for Planning 25-09-2015

T1: TENDER ISSUE 20-10-2015

T2: AMENDED TO SUIT FIRE PLAN 11-12-2015

T3: FUME CUPBOARDS AMENDED 18-12-2015

T4: VE REISSUE FOR TENDER 04-07-2016

TENDER 1 : 100

Level 01 GA 1-1001

Room Schedule 01(First)

Level Number Name Area Occupancy

First - Level1

101 Chemistry 1 109.84 m²

First - Level1

102 Chemistry 2 90.78 m² 27

First - Level1

103 Chemistry 3 83.64 m² 27

First - Level1

104 Chemistry 4 83.77 m² 27

First - Level1

105 Chemistry 5 81.07 m²

First - Level1

106 Physics 3 80.05 m²

First - Level1

107 Physics 4 81.32 m²

First - Level1

108 Prep Room 46.02 m²

First - Level1

109 Chem. St. 15.29 m²

First - Level1

110 Balcony/Circulation

117.56 m²

First - Level1

111 Riser 3 1.10 m²

First - Level1

112 Store 3 1.18 m²

First - Level1

113 Stair 1 26.50 m²

First - Level1

114 Team Base RedundantRoom

First - Level1

115 Server 5.84 m²

First - Level1

116 St. WC 2.24 m²

First - Level1

117 St. WC 2.23 m²

First - Level1

118 Fem P. WC 13.55 m²

First - Level1

119 Male P. WC 11.85 m²

First - Level1

120 WC Lobby 13.07 m²

First - Level1

121 Stair 2 17.79 m²

First - Level1

122 Dis. WC 4.58 m²

First - Level1

123 Clnr. St. 2.23 m²

First - Level1

124 Elec Riser 2.18 m²

First - Level1

125 Mech Riser 2.27 m²

Grand total: 25 895.94 m²

• For detail setting out information see drawing4157_A231

• Refer to Room Data sheets for detail furnitureinformation

• For Window Schedule & Details see drawings 4157_A605& 4157_A606

• For Internal Door Schedule & details see drawing 4157_A607

• For Floor Finishes Plan see drawing4157_A614

All Gas, water & electrical feeds to these areas to beconcealed & in accordance with M&E design &specification

Page 3: R:4100-41994157 Prince William Secondary4157 C pHp ... · Elec Riser Entrance Lobby Fem P. WC Male P. WC Mech riser Physics 1 Physics 2 Prep Room Riser Riser 3 Room Staff Office Stair

A300

2

A301 1Lanternlight rooflight to bring lightdeep into plan depth. Single plymembrane roof finish NBS J42

Green Roof - Sedum Planting

MaintenanceAccess

LiftOverrun

Paving for Access

Photovoltaic (PV) Panels

Full Height 1100mm high tubularBalustrade with horizontalmidrail to entire perimeter tosatisfy CDM requirements &provide full access formaintenance NBS L30/560

A

RoofLight

RoofLight

BB

A402

A402

2

B DC E F G H J

1

2

3

4

5

6

8

7

Vent TA

Vent TA

Vent TA

L02

Stair 2204

D_E

X_S

02

D_IN_S01

AA

A300

Store 4205

665

1810

450

Plant Room202

L01

D_EX_S03

Condenser Compound with1.6m high levolux LX louvreson metsec/steel frame NBSL10/505 (see drawing A502)

Vent pipeFB/TA

3A410

37775 FFL

37775 FFL

37980FFL

37980FFL

Gate

Gate

Polyester powdercoated folded metalcapping RAL 7015

RWO RWORWO

RWO

RWO RWO RWO RWO

1

A412

CW-S01

L

1

A413

1

A420

Flue

Flue

Flue

Flu

eFlue

RoofLight

RoofLight

RoofLight

RoofLight

RoofLight

RoofLight

RoofLight

2 deg Fall

2 deg Fall

2� Fall

2 deg Fall

2 deg Fall

2 deg Fall

2 deg Fall

2 deg Fall

2 deg Fall

2 deg Fall

2� Fall

All rooflights to have insulated upstand as drawing4157/A420. Rooflights installed inline with DVS(Daylight & Ventilation Solutions Ltd) requirements& specification, with Polyester powder coatedaluminium flashing to match roof light RAL 7015.2No. Rooflight total. Ref: 1200 x 1200 Lamilux FE3polyester Powder Coated aluminium rooflight toacheive 1.5 'U' value NBS L10/500

37980FFL

Top of brick parapet 9225Above foundation level pluscaping to allow 150mm min.above sedum blanket &ballast

37882 FFL

37882 FFL

ROOF FINISHES LEGENDNBS J31, J42, Q37

Pattern Description

Fin

ish la

yer

depth

Substr

ate

depth

Roof finish & accessories by Bauder. To be installed by approved contractor in linewith Bauder's specification & installation requirements

All roof coverings to acheive 0.16 'U' Value

Allow insulated upstand to all parapets & wall abutments

Dra

inage

depth

insula

tion

deoth

Overa

ll ro

of

finis

h d

epth

Bauder Sedum Green roof covering onbauderflex green systemNBS J41/110 & Q37/130

48 10 20 140 218

Paving slabs to form access routeproprietary pedestal support system NBSQ37/841A on buaderflex green systemNBS J41/110

50 10 20 140 218

ballast to perimeter edges on Bauderflexgreen systemNBS Q37/460 & 840

50 10 20 140 218

Single ply roof membrane to Atrium roof &plant room roof area NBS J42/110 1.5 140 150

SCALE 1:1005m0 2.5m

Scale@ A1

CheckedDrawn

Date

Status

The Old Rectory Rectory Lane Milton Malsor

N O R T H A M P T O N

t: +44 (0)1604 858916

www.peter-haddon.com

Copyright reserved. Dimensions to be checked on site.Discrepancies to be reported before proceeding.

Rev. Date/Checked

p pHarchitects

N N 7 3 A Q

f: +44 (0)1604 859123

1 : 100

PROPOSED ROOF ACCESS LEVEL

Prince William SchoolProposed New Science Block

NOVEMBER 2014

mtp ocb

A202 T3

Herne Road, Oundle. Northamptonshire

4157

P1: Preliminary Issue for comment 12-11-2014

P2: Area schedule added 14-11-2014

P3: Footprint of building reduced to fit survey of electric cable 20-11-2014

P4:Notes amended as per PWS comments, rooflightsclarified

28-11-2014

P5: Re-drawn as sketches 4157/Sk10&SK11 agreed by PWS 12-01-2015

P6: Roof revised to suit elevations 11-03-2015

P7: Balustrade & rooflights amended 17-06-2015

P8: Roof build up amended to suit Bauder details 19-06-2015

P9: Revised for Stage D report 30-06-2015

P10: Plant room amended 28-08-2015

P11: Plant room north louvre removed 09-09-2015

P12: Issue for Planning 25-09-2015

T1: TENDER ISSUE 20-10-2015

T2: FUME CUPBOARD FLUES INDICATED 18-12-2015

T3: VE REISSUE FOR TENDER 04-07-2016

TENDER 1 : 100

Level 02 GA(Roof Access)1-1001

Page 4: R:4100-41994157 Prince William Secondary4157 C pHp ... · Elec Riser Entrance Lobby Fem P. WC Male P. WC Mech riser Physics 1 Physics 2 Prep Room Riser Riser 3 Room Staff Office Stair

A300

2

A301 1

A402

2

Vent TA

Vent cowel

Ventcowel

Bauder rainwateroutlet cover with flatroof outlet belowinstalled in line withmanufacturers detailsNBS J31/343

RWP with shoe

Lift over run

Polyester powdercoated folded metalcapping RAL 7015

Polyester powdercoated folded metalcapping RAL 7015NBS H72/421

Polyester powder coatedinternally galvanised metalgutters & downpipes

RWO RWORWO

RWO

RWO RWO RWO

RWO

38065FFL

40650 FRL

All rooflights to have insulated upstand asdrawing 4157/A420. Rooflights installed inlinewith DVS (Daylight & Ventilation Solutions Ltd)requirements & specification, with Polyesterpowder coated aluminium flashing to matchroof light RAL 7015. 2No. Rooflight total. Ref:1200 x 1200 Lamilux FE3 polyester PowderCoated aluminium rooflight to acheive 1.5 'U'value NBS L10/500

41930 FRL

To fall

1 in 4

0

To fall

1 in 4

0

To fall 1 in 80

Integral gutter withdownpipe withincolumn to separatedetail

KME Tecu Gold metalsheet horizontal Brisesoliel sun shading NBSH73/140

Rain water outlet

To fall 1 in 80

Gate

1.6m high Louvred screento form services compoundNBS L10/505 refer drawing4157/A502

Single ply roof membrane on130mm insulation on VCL, on18mm marine grade ply on furringon timber joists to provide 1 in 40fall. To achieve 0.16 U value, nbsJ42/110

Single ply roof membrane on 130mminsulation on VCL, on 18mm marinegrade ply on furring on timber joiststo provide 1 in 40 fall. To achieve0.16 U value

KME Tecu Gold metalsheet roof cladding withstanding seam NBSH73/110

Fume cubd.flue (fanposition tbc)

Fume cubd.flue (fanposition tbc)

Fume cuboardflues (fanpositions tbc)

RL03RL02

RL01

RL09RL08RL07

RL06

RL05

RL04

37980FFL

37980FFL

37980FFL

Top of brick parapet 9225Above foundation level pluscaping to allow 150mm min.above sedum blanket &ballast

ROOF FINISHES LEGENDNBS J31, J42, Q37

Pattern Description

Fin

ish la

yer

depth

Substr

ate

depth

Roof finish & accessories by Bauder. To be installed by approved contractor in linewith Bauder's specification & installation requirements

All roof coverings to acheive 0.16 'U' Value

Allow insulated upstand to all parapets & wall abutments

Dra

inage

depth

insula

tion

deoth

Overa

ll ro

of

finis

h d

epth

Bauder Sedum Green roof covering onbauderflex green systemNBS J41/110 & Q37/130

48 10 20 140 218

Paving slabs to form access routeproprietary pedestal support system NBSQ37/841A on buaderflex green systemNBS J41/110

50 10 20 140 218

ballast to perimeter edges on Bauderflexgreen systemNBS Q37/460 & 840

50 10 20 140 218

Single ply roof membrane to Atrium roof &plant room roof area NBS J42/110 1.5 140 150

SCALE 1:1005m0 2.5m

Scale@ A1

CheckedDrawn

Date

Status

The Old Rectory Rectory Lane Milton Malsor

N O R T H A M P T O N

t: +44 (0)1604 858916

www.peter-haddon.com

Copyright reserved. Dimensions to be checked on site.Discrepancies to be reported before proceeding.

Rev. Date/Checked

p pHarchitects

N N 7 3 A Q

f: +44 (0)1604 859123

1 : 100

PROPOSED ROOF PLAN

Prince William SchoolProposed New Science Block

JULY 2015

tw Checker

A222 T3

Herne Road, Oundle. Northamptonshire

4157

P1: Roof Finishes updated 28-08-2015

P2: Roof fall revised 09-09-2015

P3: Issue for Planning 25-09-2015

P4: Plant & atrium roof notes amended 09-10-2015

T1: TENDER ISSUE 20-10-2015

T2: FUME CUPBOARD FLUES INDICATED 18-12-2015

T3: VE REISSUE FOR TENDER 04-07-2016

TENDER

1 : 100

Roof Plan - 1-1001

Page 5: R:4100-41994157 Prince William Secondary4157 C pHp ... · Elec Riser Entrance Lobby Fem P. WC Male P. WC Mech riser Physics 1 Physics 2 Prep Room Riser Riser 3 Room Staff Office Stair

29

22

6

1

2

3

4

5

6

7

8

9

10

11

12

13

14

Issue Purpose:

Rev Date/Checked

pHppHp a r c h i t e c t s

Drawn by: Checked by:

Scale @ A1: Date:

CAD ref: Dwg no.: Rev:

Expansion & Re-organisation of Prince William SchoolNorthamptonshire County CouncilHerne Road, Oundle, Northants

Site - Proposed Constraints Plan Phase 2

TENDER ISSUEmtp ocb

1:500 November 2014

PWS01 4157/05 T3

P1: First Issue 26.05.15 JBP2: Amended to exclude phase 3 28.05.15 JBP3: Sports area included in Phase 2. Compound reduced to suit modular village 07-07-15 mtpP4: compound updated to suit asbestos removal. Noted added re:HV cable 24-09-15 mtpP5: Application area amended to omit block D0 25-09-15 mtpT1: TENDER ISSUE 22-10-15 mtpT2: VE Re-issue for Tender 04-07-16 mtpT3: Mobile removed, note re:gas main re-location removed for Tender 05-07-16 mtp

N

SCALE 1:50020m0 10m

Overhanging trees cut back& provide protection.

BT

AW (Foul Sewer)

HV Cables (WPD)

Gas

AW (Water)

Contractor vehicle access note:Contractor to use same main access as school during term timeno access will be allowed during following times:-08:15 - 09:3014:30 - 15:45See PCIP for further details.

Phase 2 works area, includes contractor compound/ storage area / parking / building access.

Protected Trees & Rootprotection zone.

NOTE: Fire access toschool buildings requiredthroughout project.

Cadets

Nursery

Access required toCadets / Nursery forduration of works

S L O P E

S L O P E

Gas housing

AW - PumpingStation

Possible line ofcontractor fencing.

For full details of all existingservices see utilities plansand sub-technics surveydrawing 10703_UGI-0

Gas main

Main Sewer

Remove 2x trees (T4 & T5).

Protect existing Ash treebeing retained (T3).

Access for students toremain clear.

School parkingavailable outside ofbuilding works area.

ContractorParking.

Main contractor

compound.

Modular Village

Design Technology

A0

English & Modernforeign languages

X0

C0

D0

Library

Admin

F0Sports Hall & Changing

E0

T0Science

DanceStudio

Y0Fitness,Sports &Changing

Science Block

Caretakers

Gas & Water(not on survey)

gates/crossover

Note: Contractor to surveyexact position of HV electriccable and mark-out on siteprior to any excavation in thisarea.Protect Neighbours

Tree (T2).

Page 6: R:4100-41994157 Prince William Secondary4157 C pHp ... · Elec Riser Entrance Lobby Fem P. WC Male P. WC Mech riser Physics 1 Physics 2 Prep Room Riser Riser 3 Room Staff Office Stair

6

7

8

9

1

0

Temporary Buildings

(landscaping to be completed

on removal of temporary

buildings)

New Science

Block

DN

UP

UP

Chemistry 2

002

Prep Room

008

Chemistry 4

004

Staff Office

014

Fixed Seating

Chemistry 5

005

Chemistry 1

001

Fem P. WC

015

Male P. WC

016

Chemical Store

009

Physics 2

007

Dis.WC

020

Elec Riser

023

Mech riser

024

Store 2

021

WC Lobby

017

Riser 3

012

Covered Walkway

Entrance Lobby

011

Clnr St.

022

Atrium

010

Stair 1

013

Stair 2

018

WP

FA/TB

Chemistry 3

003

Corridor

025

Store 1

037

Physics 1

006

P +2

9.78

P +29.66

P +29.675

P +29.160

P +29.66

1 in 21 gradual slope - ground graded to suitPermeable Tarmac finish

Turfed ground to suit side pathgradient

1 in 2

1 gra

dient

P +29.66

Existing banked ground - grass

Bank

ed gr

ound

- gra

ss

E +29.99

E +29.52

P +29.52

Line of notional turning head for emergencyaccess (no demarcation required) New Tarmac footpath

New

Tarm

ac pa

th

New tarmac path to suit existing &proposed level differences, allowflush concrete edge to line of newpath. NBS Q22

New

Tarm

ac fo

otpath

Remove fencingRemove retaining wall &associated footings

Break out concrete slab& lay new tarmac finish

REIN

STAT

E TA

RMAC

PLA

Y AR

EAON

REM

OVAL

OF

TEMP

ORAR

YBU

ILDIN

GS

Exitin

g Tar

mac f

ootpa

th re

taine

d

New

Tarm

ac fo

otpath

Ground regraded to suit

Ground regraded to suit

Existing Levelsretained - groundreturfed

Remove gateRemove gates

New

Tarm

ac fo

otpath

New 2.2m palisade fencing

New Tarmac footpath

NB. All new tarmac to be permeable.Entire courtyard area to be capableof withstanding emergency firevehicle loading. Sub base to S.E'sdesign & specification NBS Q22

Remove concrete kerb &make good junctionRemove lines for 1No.parking space

Grass

Gravel perimeter to sit150mm below DPC

E +29.11

Yellow thermoplasticcross hatching todemark no parking area

P +30.54

up

Existing 2.2m palisade fencing

Issue Purpose:

Rev Date/Checked

pHppHp a r c h i t e c t s

Drawn by: Checked by:

Scale @ A1: Date:

CAD ref: Dwg no.: Rev:

Expansion & Re-organisation of Prince William SchoolNorthamptonshire County CouncilHerne Road, Oundle, Northants

Science Landscape Strategy Plan

TENDERmtp ocb

1:200 September 2015

PWS219 4157/238 T2

P1: Issued for Planning 25-15-09 mtpT1: TENDER ISSUE 20-10-15 twT2: VE Science Block Tender Issue 08-07-16 mtp

N

SCALE 1:50020m0 10m

NEW RED PERMEABLE TARMAC FINISH FLUSH WITH FOOTPATH. SUB BASE SUITABLE FOR EMERGENCYVEHICLE LOADING TO S.E DESIGN & SPECIFICATION

NEW BLACK PERMEABLE TARMAC FINISH FLUSH WITH ROAD. SUB BASE SUITABLE FOR EMERGENCYVEHICLE LOADING TO S.E DESIGN & SPECIFICATION

NEW BLACK PERMEABLE TARMAC FINISH SUB BASE TO S.E DESIGN & SPECIFICATION

NOTEALL MANHOLE COVERS TO BE ADJUSTED TO SUIT NEW LEVELS

NBS Q22

NBS Q22

NBS Q22