r3

download r3

of 2

description

-shared©Unknown

Transcript of r3

POSSIBLE DESIGN QUESTIONS DAY 21. TREE RIGID, SMALL ROOTED, NON RESISTANCE TO STRONG WINDS, MEDIUM SPREAD ---- COCONUT2. MEDIUM TRUNK, MEDIUM SPREAD ROOT, RESISTANCE TO WIND, SAFE TO PLANT AT SIDE OF STRUCTURE ----- MAHOGANY3. NOT GOOD FOR THE SITE, SHALLOW ROOT, EASILY BLOWN BY WIND ----PALM TREE4. GOOD FOR SITE, DEEP ROOTED, CANNOT BE BLOWN EASILY BY WIND---- ACACIA5. STANDARD TYPE OF ROOF FOR GOVERNMENT BUILDINGS----- HIP ROOF6. HARMFUL FOR FOOTING --- SHALLOW ROOT7. BEST LOCATION FOR TREES --- SOUTHWEST8. SHOULDNT BE LOCATED AT RESIDENTIAL 1 BASEMENT--- MRF9. SHOULDNT BE LOCATED AT COMMERCIAL 2 LOBBY------ UTILITY ROOM10. WHAT TYPE OF R1 FOOTING SHOULD BE USE IF LOT IS SLOPING UPWARDS---- ISOLATED FOOTING11. AREA WHERE EXCAVATION START FOR R1 AND C2---- REAR12. WHERE SHOULD THE DOWNSPOUT FOR C2 BE LOCATED--- EMBEDMENT OR COVERING13. TYPE OF FOUNDATION THAT CANNOT AFFECT THE ADJACENT STRUCTURE----STEEL SHEET PILE14. USED TO MINIMIZE DISTURBANCE TO ADJACENT PROPERTIES---- DRIVEN PILES15. MOST ECONOMICAL LOCATION OF EXTERIOR BEAM CONNECTED TO COLUMN---END POINT16. NOT AN INDOOR EQUIPMENT--- MICROWAVE OVEN17. NOT INCLUDED IN ARCHITECTURAL INTERIORS----- FITTINGS18. NOT INCLUDED IN ARCHITECTURAL INTERIORS-----FURNISHINGS19. NOT AN ARCHITECTURAL INTERIOR ELEMENT-------EAVES20. NOT AN INTERIOR APPLIANCE----- EXHAUST FAN21. NOT GOOD HEIGHT FOR A DOOR KNOB---- 1.17M22. MAXIMUM HEIGHT OF R1 WALL FENCE WITHOUT BEAM---- 1.80M23. MAXIMUM HEIGHT OF R1 WALL FENCE WITH BEAM------2.0M24. ORDINANCE IN QUEZON CITY 30% OF ROOF DECK ARE PLANTING GREEN25. STANDARD HEIGHT FOR LAVATORY WALL MOUNTED----- 0.80M26. MINIMUM DEPTH OF TOILET FOR PHYSICALLY CHALLENGED---- 1.80M27. WHAT TYPE OF PAINT SHOULD NOT BE USED AS A FINISH FOR ENCLOSED INTERIOR SPACES----- AUTOMOTIVE LAQUER28. WHICH IS NOT PART OF AMBF------ BASEMENT29. BEST LOCATION OF BEAM CONNECTED TO A COLUMN---ALONG CENTERLINE OF COLUMN30. BEST COLOR FOR WATER PROOFING---- BLACK31. WHAT TYPE OF PAINT IS NORMALLY NOT SPRAYED---- QDE32. AFSU--- AMENITIES (support areas), FACILITIES (required spaces), SERVICES (common areas that are not considered as utilities), UTILITIES33. SIZE OF GARBAGE CHUTE--- 1.5 x 1.534. WHAT TYPE OF PROJECTION ARE NOT ALLOWED IF THE PROJECT SITE IS NEAR A TRANSFORMER----- BALCONY35. ELEVATOR USED FOR LOW RISE BUILDING---- HYDRAULIC ELEVATOR36. MINIMUM DEPTH OF ELEVATOR PIT---- 600MM37. MAXIMUM DEPTH OF ELEVATOR PIT---- 1.80M38. DIFFERENCE BETWEEN PLUMBING AND ELECTRICAL--- FITTINGS39. WHY SEPTIC TANK MUST NOT BE LOCATED UNDER GARAGE---- BECAUSE THERES NO AIR THERE40. NOT GOOD LOCATION FOR WINDOWS--- SOUTHWEST (habagat wind)41. WHAT DO YOU CALL A MOVING RAMP---- TRAVELLATOR42. ABSORPTIVE MATERIALS---- BRICKS, WOOD, CHB43. NON ABSORPTIVE MATERIAL----- GLASS44. MOST EFFECTIVE MATERIAL AGAINST ECHO--- HEAVY CURTAIN45. BEST LOCATION FOR COOLING TOWER OF AIRCON---- ROOF DECK46. BEST CEILING MATERIAL----- GYPSUM BOARD47. MATERIAL NOT USED FOR UNDERGROUND---- PVC