4
E1 Emulator R0E000010KCE00E20 Emulator R0E000200KCT00
Users Manual
Rev.4.00 May 2014
All information contained in these materials, including products and product specifications,represents information on the product at the time of publication and is subject to change byRenesas Electronics Corporation without notice. Please review the latest information publishedby Renesas Electronics Corporation through various means, including the Renesas ElectronicsCorporation website (http://www.renesas.com).
-
8/10/2019 R0E000010KCE00 emulador renessas
2/39
Notice
1. Descriptions of circuits, software and other related information in this document are provided only to illustrate the operation ofsemiconductor products and application examples. You are fully responsible for the incorporation of these circuits, software,
and information in the design of your equipment. Renesas Electronics assumes no responsibility for any losses incurred by youor third parties arising from the use of these circuits, software, or information.
2. Renesas Electronics has used reasonable care in preparing the information included in this document, but Renesas Electronicsdoes not warrant that such information is error free. Renesas Electronics assumes no liability whatsoever for any damages
incurred by you resulting from errors in or omissions from the information included herein.3. Renesas Electronics does not assume any liability for infringement of patents, copyrights, or other intellectual property rights of
third parties by or arising from the use of Renesas Electronics products or technical information described in this document. Nolicense, express, implied or otherwise, is granted hereby under any patents, copyrights or other intellectual property rights of
Renesas Electronics or others.
4. You should not alter, modify, copy, or otherwise misappropriate any Renesas Electronics product, whether in whole or in part.
Renesas Electronics assumes no responsibility for any losses incurred by you or third parties arising from such alteration,modification, copy or otherwise misappropriation of Renesas Electronics product.
5. Renesas Electronics products are classified according to the following two quality grades: Standard and High Quality. Therecommended applications for each Renesas Electronics product depends on the products quality grade, as indicated below.
Standard: Computers; office equipment; communications equipment; test and measurement equipment; audio and visualequipment; home electronic appliances; machine tools; personal electronic equipment; and industrial robots etc.
High Quality: Transportation equipment (automobiles, trains, ships, etc.); traffic control systems; anti-disaster systems; anti-
crime systems; and safety equipment etc.Renesas Electronics products are neither intended nor authorized for use in products or systems that may pose a direct threat to
human life or bodily injury (artificial life support devices or systems, surgical implantations etc.), or may cause serious propertydamages (nuclear reactor control systems, military equipment etc.). You must check the quality grade of each RenesasElectronics product before using it in a particular application. You may not use any Renesas Electronics product for any
application for which it is not intended. Renesas Electronics shall not be in any way liable for any damages or losses incurredby you or third parties arising from the use of any Renesas Electronics product for which the product is not intended by Renesas
Electronics.
6. You should use the Renesas Electronics products described in this document within the range specified by Renesas Electronics,
especially with respect to the maximum rating, operating supply voltage range, movement power voltage range, heat radiationcharacteristics, installation and other product characteristics. Renesas Electronics shall have no liability for malfunctions or
damages arising out of the use of Renesas Electronics products beyond such specified ranges.
7. Although Renesas Electronics endeavors to improve the quality and reliability of its products, semiconductor products have
specific characteristics such as the occurrence of failure at a certain rate and malfunctions under certain use conditions. Further,Renesas Electronics products are not subject to radiation resistance design. Please be sure to implement safety measures toguard them against the possibility of physical injury, and injury or damage caused by fire in the event of the failure of a Renesas
Electronics product, such as safety design for hardware and software including but not limited to redundancy, fire control andmalfunction prevention, appropriate treatment for aging degradation or any other appropriate measures. Because the evaluation
of microcomputer software alone is very difficult, please evaluate the safety of the final products or systems manufactured byyou.
8. Please contact a Renesas Electronics sales office for details as to environmental matters such as the environmental compatibilityof each Renesas Electronics product. Please use Renesas Electronics products in compliance with all applicable laws and
regulations that regulate the inclusion or use of controlled substances, including without limitation, the EU RoHS Directive.Renesas Electronics assumes no liability for damages or losses occurring as a result of your noncompliance with applicable laws
and regulations.
9. Renesas Electronics products and technology may not be used for or incorporated into any products or systems whose
manufacture, use, or sale is prohibited under any applicable domestic or foreign laws or regulations. You should not use
Renesas Electronics products or technology described in this document for any purpose relating to military applications or useby the military, including but not limited to the development of weapons of mass destruction. When exporting the RenesasElectronics products or technology described in this document, you should comply with the applicable export control laws andregulations and follow the procedures required by such laws and regulations.
10. It is the responsibility of the buyer or distributor of Renesas Electronics products, who distributes, disposes of, or otherwise
places the product with a third party, to notify such third party in advance of the contents and conditions set forth in thisdocument, Renesas Electronics assumes no responsibility for any losses incurred by you or third parties as a result ofunauthorized use of Renesas Electronics products.
11. This document may not be reproduced or duplicated in any form, in whole or in part, without prior written consent of Renesas
Electronics.
12. Please contact a Renesas Electronics sales office if you have any questions regarding the information contained in this document
or Renesas Electronics products, or if you have any other inquiries.
(Note 1) Renesas Electronics as used in this document means Renesas Electronics Corporation and also includes its majority-
owned subsidiaries.
(Note 2) Renesas Electronics product(s) means any product developed or manufactured by or for Renesas Electronics.
(2012.4)
-
8/10/2019 R0E000010KCE00 emulador renessas
3/39
E1/E20 Emulator Preface
R20UT0398EJ0400 Rev.4.00 Page 3 of 39
May 16, 2014
Preface
The E1 emulator (R0E000010KCE00) and the E20 emulator (R0E000200KCT00) are designed for use with the
MCUs made by Renesas Electronics.
All components of the E1 and E20 emulators are listed under 1.1 Package Components. If you have any
questions about the E1 or E20 emulator, contact your local distributor.
Documentation for the E1/E20 emulator manual is in two parts: the E1/E20 Emulator Users Manual (this manual)
and the E1/E20 Emulator Additional Document for the Users Manual. Different versions of the latter correspond
to different sets of MCUs.
This users manual describes mainly the hardware specifications of the E1 and E20 emulators. For information on
emulator debuggers and other related products, please see the additional document for users manuals included
with each product.
You can download the latest manuals from the Renesas Tools homepage.
[E1] http://www.renesas.com/e1
[E20] http://www.renesas.com/e20
-
8/10/2019 R0E000010KCE00 emulador renessas
4/39
E1/E20 Emulator Important
R20UT0398EJ0400 Rev.4.00 Page 4 of 39
May 16, 2014
Important
Before using the emulator, be sure to read this user s manual carefully.
Keep this users manual, and refer to it when you have questions about the emulator.
Emulator:
"Emulator" in this users manual collectively refers to the E1 and E20 emulators manufactured by Renesas
Electronics Corporation.
"Emulator" herein encompasses neither the customer's user system nor the host machine.
Purpose of use of the emulator:
This emulator is a device to support the development of systems that uses the Renesas microcomputers. It provides
support for system development in both software and hardware. By using in combination with a programming
software, it is available as a Flash programming tool.
Be sure to use the emulator correctly according to said purpose of use. Please avoid using the emulator other than
for its intended purpose of use.
For those who use the emulator:The emulator can only be used by those who have carefully read the users manual and know how to use it.
Use of the emulator requires basic knowledge of electric circuits, logical circuits, and MCUs.
When using the emulator:
(1) The emulator is a development-support unit for use in your program development and evaluation stages.
When a program you have finished developing is to be incorporated in a mass-produced product, the
judgment as to whether it can be put to practical use is entirely your own responsibility, and should be based
on evaluation of the device on which it is installed and other experiments.
(2) In no event shall Renesas Electronics Corporation be liable for any consequence arising from the use of the
emulator.
(3) Renesas Electronics Corporation strives to provide workarounds for and correct trouble with products
malfunctions, with some free and some incurring charges. However, this does not necessarily mean that
Renesas Electronics Corporation guarantees the provision of a workaround or correction under any
circumstances.
(4) The emulator covered by this document has been developed on the assumption that it will be used for
program development and evaluation in laboratories. Therefore, it does not fall within the scope of
applicability of the Electrical Appliance and Material Safety Law and protection against electromagnetic
interference when used in Japan.
(5) Renesas Electronics Corporation cannot predict all possible situations and possible cases of misuse that carry
a potential for danger. Therefore, the warnings in this user's manual and the warning labels attached to the
emulator do not necessarily cover all such possible situations and cases. The customer is responsible for
correctly and safely using the emulator.
(6) This emulator has acquired the standards shown in "1.5 Regulatory Compliance Notices". This fact must betaken into account when the emulator is taken from Japan to some other country.
(7) Renesas Electronics Corporation will not assume responsibility of direct or indirect damage caused by an
accidental failure or malfunction in the emulator.
When disposing of the emulator:
Penalties may be applicable for incorrect disposal of this waste, in accordance with your national legislation.
-
8/10/2019 R0E000010KCE00 emulador renessas
5/39
E1/E20 Emulator Important
R20UT0398EJ0400 Rev.4.00 Page 5 of 39
May 16, 2014
Usage restrictions:
The emulator has been developed as a means of supporting system development by users. Therefore, do not use it
as an embedded device in other equipment. Also, do not use it to develop systems or equipment for use in the
following fields.
(1) Transportation and vehicular
(2) Medical (equipment that has an involvement in human life)
(3) Aerospace
(4) Nuclear power control
(5) Undersea repeaters
If you are considering the use of the emulator for one of the above purposes, please be sure to consult your local
distributor.
About product changes:
We are constantly making efforts to improve the design and performance of our product. Therefore, the
specification or design of the emulator, or this user's manual, may be changed without prior notice.
About rights:
(1) We assume no responsibility for any damage or infringement on patent rights or any other rights arising from
the use of any information, products or circuits presented in this users manual.
(2) The information or data in this users manual does not implicitly or otherwise grant a license to patent rights
or any other rights belonging to Renesas or to a third party.
(3) This users manual and the emulator are copyrighted, with all rights reserved by Renesas. This users manual
may not be copied, duplicated or reproduced, in whole or part, without prior written consent from Renesas.
About diagrams:
Some diagrams in this users manual may differ from the objects they represent.
-
8/10/2019 R0E000010KCE00 emulador renessas
6/39
E1/E20 Emulator Precautions for safety
R20UT0398EJ0400 Rev.4.00 Page 6 of 39
May 16, 2014
Precautions for Safety
This chapter, by showing the relevant diagrammatic symbols and their meanings, describes the precautions which
should be taken in order to use this product safely and properly. Be sure to read and understand this chapter before
using this product.
Contact us if you have any questions about the precautions described here.
WARNINGWARNING indicates a potentially dangerous situation that will cause death or heavy
wound unless it is avoided.
CAUTIONCAUTION indicates a potentially dangerous situation that will cause a slight injury or
a medium-degree injury or property damage unless it is avoided.
To avoid a possible danger, the following diagrammatic symbols are used to call your attention.
means WARNING or CAUTION.
Example:CAUTION AGAINST AN ELECTRIC SHOCK
means PROHIBITION.
Example:DISASSEMBLY PROHIBITED
means A FORCIBLE ACTION.
Example:UNPLUG THE POWER CABLE FROM THE RECEPTACLE.
-
8/10/2019 R0E000010KCE00 emulador renessas
7/39
E1/E20 Emulator Precautions for safety
R20UT0398EJ0400 Rev.4.00 Page 7 of 39
May 16, 2014
WARNINGWarnings for AC Power Supply:
Do not repair or remodel the emulator product by yourself in order to prevent danger such as an
electric shock or fire and for the sake of quality assurance. For after-sale services in case of a
mechanical or electrical fault, please contact your local distributor.
Always switch off the host computer and user system before connecting or disconnecting any cables
or parts. Neglect of this precaution will result in getting an electric shock or will result in the emulator
product or user system emitting smoke or catching fire. Also, the user program under debug will be
destroyed.
Make sure that the connectors on both ends of the user-system interface cable are facing the right
way relative to the user-side connector on the emulator and the connector on the user system,
respectively.
Neglect of this precaution will result in getting an electric shock or will result in the emulator product or
user system emitting smoke or catching fire.
Warning fo r Modification:
Do not modify the emulator. Personal injury due to electric shock may occur if the emulator is
modified. Modifying the product will void your warranty.
Warning for Installation:
Do not set the emulator in water or areas of high humidity. Make sure that the product does not get
wet. Spilling water or some other liquid into the product may cause un-repairable damage.
Warning for Use temperature:
The emulator is to be used in an environment with a maximum ambient temperature of 35C.
Care should be taken that this temperature is not exceeded.
-
8/10/2019 R0E000010KCE00 emulador renessas
8/39
E1/E20 Emulator Precautions for safety
R20UT0398EJ0400 Rev.4.00 Page 8 of 39
May 16, 2014
CAUTIONCautions to Be Taken for Handling The emulator:
Use caution when handling the emulator. Be careful not to apply a mechanical shock.
Do not touch the connector pins of the emulator and the target MCU connector pins directly. Static
electricity may damage the internal circuits.
When attaching and removing the cable, hold the plug of the cable and do not touch the cable. When
installing the emulator, do not flex the cable excessively or pull the emulator or the board by the cable
connected to it. The cable may cause a break.
Do not tape the flexible cable or apply adhesives to secure the cable. The shielding material on the
surface of the cable may come off.
Caution to Be Taken for System Malfunctions:
If the emulator malfunctions because of interference like external noise, do the following to remedy
the trouble.
(1) Exit the emulator debugger, and shut OFF the emulator and the user system.(2) After a lapse of 10 seconds, turn ON the power of the emulator and the user system again, then
launch the emulator debugger.
Caution to Be Taken for Disposal:
Penalties may be applicable for incorrect disposal of this waste, in accordance with your national
legislation.
European Union regulatory notices:
The WEEE (Waste Electrical and Electronic Equipment) regulations put responsibilities on producers
for the collection and recycling or disposal of electrical and electronic waste. Return of WEEE under
these regulations is applicable in the European Union only. This equipment (including all accessories)
is not intended for household use. After use the equipment cannot be disposed of as household
waste, and the WEEE must be treated, recycled and disposed of in an environmentally soundmanner.
Renesas Electronics Europe GmbH can take back end of life equipment, register for this service at
http://www.renesas.eu/weee
-
8/10/2019 R0E000010KCE00 emulador renessas
9/39
E1/E20 Emulator Contents
R20UT0398EJ0400 Rev.4.00 Page 9 of 39
May 16, 2014
Contents
Page
Preface............................................................................................................................................................... 3
Important ............................................................................................................................................................ 4
Precautions for Safety ....................................................................................................................................... 6
Contents ............................................................................................................................................................. 9
Terminology ..................................................................................................................................................... 10
1. Outline .......................................................................................................................................................... 11
1.1. Package Components ........................................................................................................................ 11
1.2. System Configuration ........................................................................................................................ 12
1.3. PC Interface ....................................................................................................................................... 12
1.4. Specifications..................................................................................................................................... 13
1.5. Regulatory Compliance Notices ........................................................................................................ 14
1.5.1. European Union regulatory notices ......................................................................................... 14
1.5.2. United States Regulatory notices ............................................................................................ 14
1.6. Emulator Hardware Configuration ..................................................................................................... 15
1.7. The Names of the Emulator Parts ..................................................................................................... 161.8. Operating Environment ..................................................................................................................... 17
2. Setup............................................................................................................................................................ 18
2.1. Installing Emulator Software .............................................................................................................. 18
2.2. Connecting the Emulator to the Host Computer ............................................................................... 18
2.3. Connecting the Emulator to the User System ................................................................................... 19
2.4. Turning the Power On/Off .................................................................................................................. 23
2.4.1. When a Separate Power Supply is Used for the User System ............................................... 23
2.4.2. When Power is supplied to the User System from the Emulator (E1 Only) ............................ 24
2.5. Connecting System Ground .............................................................................................................. 25
3. Troubleshooting (Action in Case of an Error) .............................................................................................. 26
3.1. How to Solve a Trouble ..................................................................................................................... 26
3.1.1. ACTION LED does not light .................................................................................................... 26
3.1.2. Unconnectable with the debugger........................................................................................... 26
3.2. How to Request Support ................................................................................................................... 26
4. Maintenance and Warranty .......................................................................................................................... 27
4.1. Maintenance ...................................................................................................................................... 27
4.2. Warranty ............................................................................................................................................ 27
4.3. Repair Provisions .............................................................................................................................. 28
4.4. How to Make Request for Repair ...................................................................................................... 28
Appendix A Self-Checking Program (SCP)...................................................................................................... 29
A.1 Flow of Self-Checking ........................................................................................................................ 29
A.2 Preparations for Self-Checking .......................................................................................................... 30
A.3 Executing the Self-Checking Program ............................................................................................... 31
-
8/10/2019 R0E000010KCE00 emulador renessas
10/39
E1/E20 Emulator Terminology
R20UT0398EJ0400 Rev.4.00 Page 10 of 39
May 16, 2014
Terminology
Some specific words used in this user's manual are defined below.
Integrated development environment: High-performance Embedded Workshop
This tool provides powerful support for the development of embedded applications for Renesas microcomputers. It
has an emulator debugger function allowing the emulator to be controlled from the host machine via an interface.
Furthermore, it permits a range of operations from editing a project to building and debugging it to be performed
within the same application. In addition, it supports version management.
Emulator debugger
This means a software tool that is started up from the High-performance Embedded Workshop, and controls the
emulator and enables debugging.
Programming software
This means Flash Development Toolkit or Renesas Flash Programmer that is available on the emulator.
Host machineThis means a personal computer used to control the emulator.
Target MCU
This means the MCU to be debugged.
User system
This means a user's application system in which the MCU to be debugged is used.
User program
This means the program to be debugged.
-
8/10/2019 R0E000010KCE00 emulador renessas
11/39
E1/E20 Emulator Outline
R20UT0398EJ0400 Rev.4.00 Page 11 of 39
May 16, 2014
1. Outline
This chapter describes the package components, the system configuration, and the specifications of the emulator
functions and operating environment.
1.1. Package Components
The E1/E20 emulator package consists of the following items. After you have unpacked the box, check if your E1
or E20 emulator contains all of these items. Table 1.1 and Table 1.2 show the packing components for the E1 and
E20, respectively.
Table 1.1 Package components for the E1
Item Quantity
Main E1 emulator unit (R0E000010KCE00) 1
USB interface cable (A plug mini-B plug, 1.5 m, high-speed grade) 1
User-system interface cable (14-pin flat cable, 15cm) 1
CD-ROM
- Guide to the software information page
- Self-Checking Program
- E1/E20 Emulator Users Manual
1
Table 1.2 Package components for the E20
Item Quantity
Main E20 emulator unit (R0E000200KCT00) 1
USB interface cable (A plug mini-B plug, 1.5 m, high-speed grade) 1
User-system interface cable (38-pin flexible cable, 20cm) 1
38-pin to 14-pin conversion adapter (R0E000200CKA00) 1
CD-ROM
- Guide to the software information page
- Self-Checking Program
- E1/E20 Emulator Users Manual
1
Please keep the E1/E20 emulator's packing box and cushioning materials at hand for later reuse in sending the
product for repairs or for other purposes. Always use the original packing box and cushioning material when
transporting the E1 or E20 emulator.
-
8/10/2019 R0E000010KCE00 emulador renessas
12/39
E1/E20 Emulator Outline
R20UT0398EJ0400 Rev.4.00 Page 12 of 39
May 16, 2014
1.2. System Configuration
The E1 or E20 emulator is used by connecting it to the target MCU mounted on the user system.
Figure 1.1 shows the configuration of the emulator system.
Host computer
E1 or E20 emulatorUSB interface cable
User system
User-system interface cable(with the 14-or 38-pin connector)
+Integrated Development Environment
Emulator debigger
Figure 1.1 System configuration with an Emulator
(1) E1 or E20 emulator (this product)
(2) USB interface cable (included)
(3) User-system interface cable (included)
(4) User system
This is your application system using the MCU to be debugged. The E20 emulator cannot supply power to the
user system. Get a power supply separately.(5) Host machine
A personal computer to control the emulator by USB interface.
1.3. PC Interface
USB Interface *1
USB 2.0 high-speed (also connectable to the USB 1.1-compatible host machine)
Note: 1 Not guaranteed to operate in any combination of a host machine, USB device, and USB hub.
-
8/10/2019 R0E000010KCE00 emulador renessas
13/39
E1/E20 Emulator Outline
R20UT0398EJ0400 Rev.4.00 Page 13 of 39
May 16, 2014
1.4. Specifications
Table 1.3 lists the specifications of the E1 or E20 emulator.
Table 1.3 Specifications of the E1 or E20 emulator
Item Description
Emulator Type E1 EmulatorType name: R0E000010KCE00
E20 EmulatorType name: R0E000200KCT00
PC Interface USB 2.0 (high speed/ full speed)
User Interface 14-pin connector
7614-6002 [Sumitomo 3M Limited]
2514-6002 [3M Limited]
38-pin connector
2-5767004-2 [Tyco Electronics Japan
G.K.]
Power Voltage for
the emulator
USB-bus power supply (VBUS 4.5 V, min / 500 mA, min)
Power supply for
the target MCU
Supplied from the user system or
Supplied from the E1 emulator (200 mA,
max *)
Supplied from the user system
External dimension
(main body)
109.4 mm 53.2 mm 18.6 mm 114.9 mm 74.2 mm 19.2 mm
Weight 72g 103g
Operating temperature 5 to 35C (no condensation)
Storage temperature -10 to 60C (no condensation)
EMC EU: EN 55022 Class A, EN 55024
USA: FCC part 15 Class A
Note: If you can supply 500mA from USB VBUS
-
8/10/2019 R0E000010KCE00 emulador renessas
14/39
E1/E20 Emulator Outline
R20UT0398EJ0400 Rev.4.00 Page 14 of 39
May 16, 2014
1.5. Regulatory Compliance Notices
1.5.1. European Union regulatory noti ces
This product complies with the following EU Directives. (These directives are only valid in the European Union.)
CE Certifications:Electromagnetic Compatibility (EMC) Directive 2004/108/EC
EN 55022 Class A
WARNING: This is a Class A product. This equipment can cause radio frequency noise when used in the
residential area. In such cases, the user/operator of the equipment may be required to take
appropriate countermeasures under his responsibility.
EN 55024
Information for traceability
Authorised representative
Name: Renesas Electronics CorporationAddress: 1753, Shimonumabe, Nakahara-ku, Kawasaki, Kanagawa, 211-8668, Japan
Manufacturer
Name: Renesas Solutions Corp.
Address: Nippon Bldg., 2-6-2, Ote-machi, Chiyoda-ku, Tokyo 100-0004, Japan
Person responsible for placing on the market
Name: Renesas Electronics Europe Limited
Address: Dukes Meadow, Millboard Road, Bourne End, Buckinghamshire, SL8 5FH, U.K.
Trademark and Type name
Trademark: Renesas
Product name: E1 Emulator / E20 Emulator
Type name: R0E000010KCE00 / R0E000200KCT00
Environmental Compliance and Certifications:Waste Electrical and Electronic Equipment (WEEE) Directive 2012/19/EU
1.5.2. United States Regulatory notices
This product complies with the following EMC regulation. (This is only valid in the United States.)
FCC Certifications:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
-
8/10/2019 R0E000010KCE00 emulador renessas
15/39
E1/E20 Emulator Outline
R20UT0398EJ0400 Rev.4.00 Page 15 of 39
May 16, 2014
1.6. Emulator Hardware Configuration
As shown in Figures 1.2 and 1.3, the emulator consists of a main emulator unit, a USB interface cable, and a user-
system interface cable. The emulator is connectable to the host computer via a USB port compliant with USB 2.0
(Full-Speed/High-Speed) or USB 1.1.
SELF CHECK
ACT
RUN
VCC
RESET
USB interface cable
E1 main emulator unit
User-system interface cable
Figure 1.2 E1 Hardware Configuration
USB interface cable
E20 main emulator unit
User-system interface cable
SELF CHECK
ACT
VCC
RUN
RESETTOP
Optional 38-pin to 14-pinconversion adapterincluded in the package
Note: The 38-pin to 14-pin conversion adapter is used to connect the E20 to a board on which a 14-pin
connector is mounted.
Figure 1.3 E20 Hardware Configuration
-
8/10/2019 R0E000010KCE00 emulador renessas
16/39
E1/E20 Emulator Outline
R20UT0398EJ0400 Rev.4.00 Page 16 of 39
May 16, 2014
1.7. The Names of the Emulator Parts
The names of the emulator parts are given in Figures 1.4 to 1.6.
E1 Emulator E20 Emulator
ACT RESET
VCC
SELF CHECK
RUN
(a)
(c)(d)
(e)
(f)(b)
TOP
SELF CHECK
ACT RESET
VCC
RUN
(a) (d)
(e)(c)
(b) (f)
(a) Logotype: The casing bears the RENESAS E1 or RENESAS E20 logotype.
(b) Connector for
self-checking:
A connector for use in self-checking. The lid is usually closed because this connector is not
used during debugging. For details on the self-checking procedure, refer to appendix A.(c) ACTIVE LED: Marked ACT. This LED indicates the operating state of the E1 or E20 control software.
Illuminated: The emulator is usable.
Blinking: The USB driver has not been recognized (e.g. the USB driver has not correctly
been installed).
Not illuminated: The emulator is not usable for some reason.
(d) VCC LED: Marked VCC. This LED indicates the current state of power supply to the user system.
Illuminated (orange): The emulator is supplying power to the user system.
Illuminated (yellowish green): External power for the user system is on.
Not illuminated: The user system is not being supplied with power.
(e) RESET LED: Marked RESET. This LED indicates whether or not the signal on the MCU RESET pin of the
user system is being enabled.
Illuminated: The reset signal is enabled.Not illuminated: The reset signal is disabled.
(f) RUN LED: Marked RUN. This LED indicates whether or not the MCU on the user system is running.
Illuminated: The user program is running.
Not illuminated: A break in execution of the user program
Figure 1.4 E1 and E20 Top View
-
8/10/2019 R0E000010KCE00 emulador renessas
17/39
E1/E20 Emulator Outline
R20UT0398EJ0400 Rev.4.00 Page 17 of 39
May 16, 2014
E1 Emulator E20 Emulator
(a)
(b)
I O
(c)(b)(a)
(a) Host-side connector: A USB connector for the host computer.
Be sure to connect the provided USB interface cable.
(b) Host-side connector mark: Marked .
A connector for the host computer is provided at the side of this mark.
(c) Power switch (E20 only): Power switch of the emulator.
When the switch is shifted to |, the power is on. Shifting the switch to , on
the other hand, turns off the power.
The USB supplies power to the emulator.
Figure 1.5 E1 and E20 Host-Side View
E1 Emulator E20 Emulator
USER I/F
(a)
(b)
USER I/F
(a)
(b)
(a) User-side connector: A user-system interface cable is connected.
(b) User-side connector mark: Marked USER I/F.
A connector for the user-system interface cable is provided at the side of this
mark.
Figure 1.6 E1 and E20 User-Side View
1.8. Operating Environment
Observe the conditions listed in Table 1.4 when using the emulator.
Table 1.4 Operating environmental conditions
Item Description
Temperature Operating: +5C to +35C
Storage: 10C to +60C
Humidity 35% RH to 80% RH, no condensation
Vibration Operating: 2.45 m/s2 max.
Storage: 4.9 m/s2 max.
Transportation: 14.7 m/s2 max.
Ambient gases No corrosive gases may be present
-
8/10/2019 R0E000010KCE00 emulador renessas
18/39
E1/E20 Emulator Setup
R20UT0398EJ0400 Rev.4.00 Page 18 of 39
May 16, 2014
2. Setup
2.1. Installing Emulator Software
Insert the installation media into the host machine. Follow the displayed procedure to download and install the
emulator software.
2.2. Connecting the Emulator to the Host Computer
Use the USB interface cable to connect the emulator to the host computer as shown in Figure 2.1.
For the position of each connector of the emulator, refer to section 1.7, The Names of the Emulator Parts.
Host computer
USB interface cable(1.5m)E1 or E20 emulator
Figure 2.1 System Configuration when Connecting the Emulator to the Host Computer
(1) Connect the A plug of the USB interface cable to the USB I/F connector of the host machine.
(2) Connect the mini-B plug of the USB interface cable to the USB I/F connector of the E1 or E20 emulator.
The USB interface cable included with the product conforms to the USB 2.0 high-speed standard.
When you use the E1 or E20 emulator, be sure to use the USB interface cable supplied with it.The E1 emulator is turned on by connecting the USB interface cable. When using the E20 emulator, turn on its
power switch.
The E20 emulator is turned on when the power switch is shifted to the on position after connecting the USB
interface cable.
On Windows Vista, Windows 7, Windows 8 and Windows 8.1, the USB driver is automatically installed.
On Windows XP, the USB driver is installed first time the emulator is turned on.
When Can Windows connect to Windows Update to search for software? is displayed, select No, not this time
and then click on [Next]. When What do you want the wizard to do? is displayed, select Install the software
automatically (Recommended) and then click on [Next].
If the USB port of the host machine or the emulator to be connected is changed, the USB driver is re-installed.
-
8/10/2019 R0E000010KCE00 emulador renessas
19/39
E1/E20 Emulator Setup
R20UT0398EJ0400 Rev.4.00 Page 19 of 39
May 16, 2014
2.3. Connecting the Emulator to the User System
Use the procedure below to connect the emulator to the user system with the user-system interface cable, or to
disconnect them when moving the emulator or the user system.
(1) Connect the user-system interface cable to the user-side connector of the emulator.
When connecting the user-system interface cable to the E1 emulator, check the position of the erroneousinsertion prevention key to ensure that the cable is plugged in correctly.
When connecting the user-system interface cable to the E20 emulator, check to see that the cable is plugged in
correctly, with the TOP side of its connector cover up.
USER I/F
User-side connector
USER I/F
User-side connector
E1 Emulator E20 Emulator
Figure 2.2 User-Side Connector on the E1 and E20
CAUTIONNotes on connector insertion and removal:
When connecting or disconnecting the user-system interface cable and the emulator or user system,
grasp the connector cover at the end of the cable. Pulling the cable itself will damage the wiring.
Also, be aware that the user-system interface cable has the direction in which it must be inserted. If
the cable is connected in the wrong direction, it may break down.
Correct example Incorrect example
-
8/10/2019 R0E000010KCE00 emulador renessas
20/39
E1/E20 Emulator Setup
R20UT0398EJ0400 Rev.4.00 Page 20 of 39
May 16, 2014
(2) A connector to the user-system interface cable must be installed on the user system. Table 2.1 shows the
recommended connector for the emulator.
Table 2.1 Recommended Connector
Connector Type Number Manufacturer Specifications
14-pin connector 7614-6002 Sumitomo 3M Limited 14-pin straight type (Japan)
2514-6002 3M Limited 14-pin straight type (other countries)
38-pin connector 2-5767004-2 Tyco Electronics Japan G.K. 38-pin type
(3) For the pin assignments of the connector, refer to the separate MCU-specific manual for the emulator.
(4) Connect one end of the user-system interface cable to the emulator and the other end to the connector on the
user system as shown in Figures 2.3, 2.4, and 2.5.
14-pin user-system interface cable
14-pin connector
7614-6002 or2514-6002
User system
Pin 1
Pin 2
Figure 2.3 Connecting the User-System Interface Cable to the User System when the 14-PinConnector is in Use with the E1
CAUTIONNotes on connector insertion and removal:
When connecting or disconnecting the user-system interface cable and the emulator or user system,
grasp the connector cover at the end of the cable. Pulling the cable itself will damage the wiring.
Correct example Incorrect example
-
8/10/2019 R0E000010KCE00 emulador renessas
21/39
E1/E20 Emulator Setup
R20UT0398EJ0400 Rev.4.00 Page 21 of 39
May 16, 2014
38-pin to 14-pin conversion adapter (top view)R0E000200CKA00
(include in the E20 package)10 mm
User system
38-pin user-system interface cable
26.2 mm
9.4mm38-pin to 14-pin
conversion adapter
9.4 mm
14-pin connector
7614-6002 or2514-6002
Figure 2.4 Connecting the User-System Interface Cable to the User System when the 14-Pin
Connector is in Use with the E20
CAUTIONLimit to the height on connector periphery:
For a case where the R0E000200CKA00 is used for connecting the E20 emulator to a 14-pin
connector:
When designing the layout of a user board with a 14-pin connector, do not mount other
components with a height of 10 mm or more within 5 mm of the connector on the user system.
-
8/10/2019 R0E000010KCE00 emulador renessas
22/39
E1/E20 Emulator Setup
R20UT0398EJ0400 Rev.4.00 Page 22 of 39
May 16, 2014
Connector (top view)
: Area with limit on mounted components
5 mm
User system
38-pin user-system interface cable
38-pin connector
-5767004-2
30 mm
15m
m
137
38 2
Figure 2.5 Connecting the User-System Interface Cable to the User System when the 38-Pin
Connector is in Use with the E20
CAUTION
Limit to the height on connector periphery:For a case where the E20 emulator is connected to a 38-pin connector:
When designing the layout of a user board with a 38-pin connector, reduce cross-talk noise etc. by
keeping other signal lines out of the region where the connector is situated. As shown in Figure 2.5,
an upper limit (5 mm) applies to the heights of components mounted around the connector on the
user system (indicated by area with limit on mounted components in the figure).
-
8/10/2019 R0E000010KCE00 emulador renessas
23/39
E1/E20 Emulator Setup
R20UT0398EJ0400 Rev.4.00 Page 23 of 39
May 16, 2014
2.4. Turning the Power On/Off
Turn the power of the E1 or E20 emulator and the user system following the procedure below.
2.4.1. When a Separate Power Supp ly is Used for the User System
(1) Check the power is off.
Check that the user system is turned off. When using the E20 emulator, check its power switch is off.
(2) Connect the user system.
Connect the emulator and the user system with a user-system interface cable.
(3) Connect the host machine and turn on the emulator.
Connect the emulator and the host machine with a USB interface cable. The E1 emulator is turned on by
connecting the USB interface cable. When using the E20 emulator, turn on its power switch.
(4) Turn on the user system
Turn on the user system.
(5) Launch the emulator debugger.
Launch the emulator debugger.
(1) Close the emulator debugger.
Close the emulator debugger.
(2) Turn off the user system.
Turn off the user system.
(3) Turn off the emulator and disconnect the emulator.
When using the E20 emulator, turn off its power switch. Disconnect the USB interface cable from the E1 or
E20 emulator. The E1 emulator is turned off by disconnecting from the USB interface cable.
(4) Disconnecting the user system
Disconnect the user-system interface cable from the user system.
CAUTIONNote on the User System Power Supply :
While the power of the user system is on, do not turn off the host machine, unplug the USB interface
cable, or turn off the power switch of the E20 emulator.
The user system may be damaged due to leakages current.
-
8/10/2019 R0E000010KCE00 emulador renessas
24/39
E1/E20 Emulator Setup
R20UT0398EJ0400 Rev.4.00 Page 24 of 39
May 16, 2014
2.4.2. When Power is suppl ied to the User System from the Emulator (E1 Only)
(1) Connect the user system.
Connect the emulator and the user system with a user-system interface cable.
(2) Connect the host machine and turn on the emulator.
Connect the emulator and the host machine with a USB interface cable, then turn on the emulator.(3) Launch the emulator debugger.
Launch the emulator debugger and select the setting of power supply to the user system.
(1) Close the emulator debugger.
Close the emulator debugger.
(2) Turn off the emulator and disconnect the emulator.
Disconnect the USB interface cable from the emulator, then turn off the emulator.
(3) Disconnecting the user system
Disconnect the user-system interface cable from the user system.
-
8/10/2019 R0E000010KCE00 emulador renessas
25/39
E1/E20 Emulator Setup
R20UT0398EJ0400 Rev.4.00 Page 25 of 39
May 16, 2014
2.5. Connecting System Ground
The emulator's signal ground is connected to the user system's signal ground.
In the emulator, the signal ground and frame ground are connected.
In the user system, connect the frame ground only; do not connect the signal ground to the frame ground (Figure
2.6).
If it is difficult to separate the frame ground from the signal ground in the user system, set the GND for DC powerinput (AC adapter) of the host computer and the frame ground of the user system as the same potential. If the GND
potential is different between the host computer and the user system, an overcurrent will flow in the low-
impedance GND line and thin lines might be burned.
WARNINGConnecting System Ground :
Separate the frame ground from the signal ground at the user system. Failure to do so will result in
smoke, fire, or an electric shock due to the difference in ground potential.
USB
E1/E20 emulator
Logic
Powersupply
Hostcomputer
Signal ground
Signal groundSignal
Frame ground
User system
Signal ground
Signal
Logic
Figure 2.6 Connecting System Ground
For a debugging environment where there is a GND gap between the user system and host PC, use the isolator
for the E1 emulator (R0E000010ACB10 / R0E000010ACB20) or the isolator for the E20 emulator
(R0E000200ACB10) that are separately available from Renesas.
-
8/10/2019 R0E000010KCE00 emulador renessas
26/39
E1/E20 Emulator Troubleshooting (Action in Case of an Error)
R20UT0398EJ0400 Rev.4.00 Page 26 of 39
May 16, 2014
3. Troubleshooting (Action in Case of an Error)
3.1. How to Solve a Trouble
The following describes how to solve a trouble when any problem occurs before the emulator debugger starts after
the emulator and the user system have been powered on. For the latest information on the emulator and emulator
debugger, visit Renesas Electronics development environment website (http://www.renesas.com/tools).
3.1.1. ACTION LED does not l igh t
(1) Keeps flashing
The USB driver is not installed correctly in the host machine.
Install the USB driver correctly.
(2) Remains off
This means that the E1 or E20 is in an unusable state for some reason. Check the following:
Whether the E1 or E20 and the host machine are connected with the USB interface cable.
Whether the power switch of the E20 is turned on.
Whether the power for the host machine is turned on.
3.1.2. Unconnectable with the debugger
(1) Check the connection between the emulator and the MCU.
For details, consult the separate E1/E20 manual for the MCU youre using.
Whether the emulator and the MCU are connected correctly.
Whether the connected signal lines are pulled up to the power supply or down to GND properly.
(2) Check to see that the MCU is in a ready state.
The MCU operating clock is on (= oscillating).
The MCU is supplied with power properly.
The MCU has been reset and is ready to go.
3.2. How to Request Support
After checking the items in Troubleshooting, contact us from the following URL.
http://www.renesas.com/contact/
For prompt response, please specify the following information:
(1) Operating environment
MCU name:
Operating frequency: [MHz]
MCU operating mode: [Mode](2) Condition
The emulator debugger starts up / does not start up
The error is detected / not detected in the self-check
Frequency of errors: always / frequency ( )
(3) Problem
-
8/10/2019 R0E000010KCE00 emulador renessas
27/39
E1/E20 Emulator Maintenance and Warranty
R20UT0398EJ0400 Rev.4.00 Page 27 of 39
May 16, 2014
4. Maintenance and Warranty
This chapter covers basic maintenance, warranty information, provisions for repair and the procedures for
requesting a repair.
4.1. Maintenance
(1) If dust or dirt collects on this product, wipe it off with a dry soft cloth. Do not use thinner or other solvents
because these chemicals can cause the surface coating to separate.
(2) When you do not use this product for a long period, disconnect it from the power supply, host machine and
user system.
4.2. Warranty
(1) This product comes with a one-year limited warranty after purchase.
Should the product break down or be damaged while youre using it under normal condition based on its
users manual, it will be repaired or replaced free of cost.
(2) However, if the following failure or damage occurs to the product under warranty, the product will be repaired
or replaced at cost.a) Failure or damage attributable to the misuse or abuse of the product or its use under other abnormal
conditions.
b) Failure or damage attributable to improper handling of the product after purchase, such as dropping of
the product when it is transported or moved.
c) Failure or damage to the product caused by other pieces of equipment connected to it.
d) Failure or damage attributable to fire, earthquakes, thunderbolts, floods, or other natural disasters or
abnormal voltages, etc.
e) Failure or damage attributable to modifications, repairs, adjustments, or other acts made to the product by
other than Renesas Electronics Corporation.
(3) Consumables (e.g., sockets and adapters) are not covered by the aforementioned repair.
In the above cases, contact your local distributor. If your product is being leased, consult the leasing company or
the owner.
-
8/10/2019 R0E000010KCE00 emulador renessas
28/39
E1/E20 Emulator Maintenance and Warranty
R20UT0398EJ0400 Rev.4.00 Page 28 of 39
May 16, 2014
4.3. Repair Provisions
(1) Repairs not covered by warranty
Problems arising in products for which more than one year has elapsed since purchase are not covered by
warranty.
(2) Replacement not covered by warrantyIf your product's fault falls into any of the following categories, the fault will be corrected by replacing the
entire product instead of repairing it, or you will be advised to purchase a new product, depending on the
severity of the fault.
- Faulty or broken mechanical portions
- Flaws, separation, or rust in coated or plated portions
- Flaws or cracks in plastic portions
- Faults or breakage caused by improper use or unauthorized repair or modification
- Heavily damaged electric circuits due to overvoltage, overcurrent or shorting of power supply
- Cracks in the printed circuit board or burnt-down patterns
- A wide range of faults that make replacement less expensive than repair- Faults that are not locatable or identifiable
(3) Expiration of the repair period
When a period of one year has elapsed after production of a given model ceased, repairing products of that
model may become impossible.
(4) Carriage fees for sending your product to be repaired
Carriage fees for sending your product to us for repair are at your own expense.
4.4. How to Make Request for Repair
If your product is found faulty, fill in a Repair Request Sheet downloadable from the following URL. And emailthe sheet and send the product to your local distributor.
http://www.renesas.com/repair
CAUTIONNote on Transporting the Product:
When sending your product for repair, use the packing box and cushioning material supplied with the
product when it was delivered to you and specify caution in handling (handling as precision
equipment). If packing of your product is not complete, it may be damaged during transportation.
When you pack your product in a bag, make sure to use the conductive plastic bag supplied with the
product (usually a blue bag). If you use a different bag, it may lead to further trouble with your product
due to static electricity.
-
8/10/2019 R0E000010KCE00 emulador renessas
29/39
E1/E20 Emulator Appendix A
R20UT0398EJ0400 Rev.4.00 Page 29 of 39
May 16, 2014
Appendix A Self-Checking Program (SCP)
This section gives the procedure for using the self-checking program for the E1 and E20 in fault analysis.
A.1 Flow of Self-Checking
Install the emulator software. Install the SCP and USB driver for the E1 and E20 on thehost computer (this step is only required once).
Connect the user interface cable. Connect one end of the user-system interface connector to
the user-side connector and the other end to the self-
checking connector on the emulator (see Figure A.1).
Do not connect the USB interface connector yet.
Connect the USB interface cable*. Connect the host computer and the emulator via the USB
interface cable and turn on the power for the emulator.
E1: The supply of power starts when the USB interface
connector is connected.
E20: The supply of power starts when the power switch isturned on after the USB interface cable has been
connected.
Initiate the SCP for the E1 and E20. Initiate the SCP.
Execute the TEST1 and TEST2 programs. Execute the TEST1 and TEST2 programs.
Disconnect the user interface cable. Remove the cable from the self-checking connector.
Execute the TEST3 program. Execute the TEST3 program.
View the results of self-checking. If the results were normal, PASS will be displayed. Ifchecking indicated a failure, FAIL will be displayed.
In the case of FAIL, a further error message is also given.
For the messages and their meanings, see Table A.1.
Note: Fault analysis of the hardware by using the self-checking program only works correctly when a single
emulator is connected to the host computer. When two or more emulators are connected, correct
operation is not guaranteed.
-
8/10/2019 R0E000010KCE00 emulador renessas
30/39
E1/E20 Emulator Appendix A
R20UT0398EJ0400 Rev.4.00 Page 30 of 39
May 16, 2014
A.2 Preparations for Sel f-Check ing
(1) The following items are required to execute the self-checking program.
E1 or E20 emulator
USB interface cable (included in the package)
User interface cable (included in the package)
Installation medium (included in the package)Host computer
The emulator software and USB driver must also be installed on the host computer in advance.
(2) Open the lid of the self-checking connector on the emulator. Then connect the user-side connector and self-
checking connector via the user interface cable.
E1 Emulator E20 Emulator
ACT RESET
VCC
SELFCHECK
RUN
User-side connector
Lid
Self-checkingconnector
TOP
SE
ACT RESET
VCC
RUN
Self-checking
Lid
User-side connector
connector
Figure A.1 Connecting the User Interface Cable (for the E1 and E20)
CAUTIONInsert the user interface cable firmly into the self-checking connector. If the connection is loose, the
result will be FAIL.
(3) Start up the host computer. Connect the host computer and the emulator via the USB interface cable and turn
on the power for the emulator. The timing with which the supply of power starts differs with the emulator.
E1: The supply of power starts when the USB interface connector is connected.
E20: The supply of power starts when the power switch is turned on after the USB interface cable has been
connected.
-
8/10/2019 R0E000010KCE00 emulador renessas
31/39
E1/E20 Emulator Appendix A
R20UT0398EJ0400 Rev.4.00 Page 31 of 39
May 16, 2014
A.3 Executing the Self-Checking Program
(1) Execute the E1/E20 Self Check Program (E1E20SCP.exe).
When installing the High-performance Embedded Workshop RX E1/E20 debugger, open the start menu and
select [Programs] -> [Renesas] -> [High-performance Embedded Workshop] -> [E1/E20 Self Check Program].
When installing the CubeSuite+, open the start menu and select [Programs] -> [Renesas Electronics
CubeSuite+] -> [Emulator Utilities] -> [RX] -> [E1, E20 Emulator Self Check Program].If you are using any other debugger product, refer to its manual, or install the self-checking program from
included installation media, then open the start menu and select [Programs -> Renesas -> E1E20SCP ->
E1E20 Self Check Program].
Figure A.2 Starting the Self-Checking Program
-
8/10/2019 R0E000010KCE00 emulador renessas
32/39
E1/E20 Emulator Appendix A
R20UT0398EJ0400 Rev.4.00 Page 32 of 39
May 16, 2014
(2) Click on the [START] button to start the self-checking program.
If the user interface cable has not been connected to the self-checking connector, the following message is
displayed:
Please connect the user interface cable to the self-check connector on E1 or E20 in a correct direction.
Check that the user interface cable is connected to the self-checking connector in the right direction as shown in
Figure A.1, and click on the [OK] button. This starts the self-checking program.
Figure A.3 Checking the Connection
If the user interface cable has not been connected to the self-checking connector when the [OK] button is clicked
on, FAIL is displayed on the screen (see figure below). Correctly connect the cable to the self-checking
connector and click on the [START] button again to start the self-checking program.
Figure A.4 [FAIL] at the Start of Self-Checking
(without the Cable Connected to the Self-Checking Connector)
-
8/10/2019 R0E000010KCE00 emulador renessas
33/39
E1/E20 Emulator Appendix A
R20UT0398EJ0400 Rev.4.00 Page 33 of 39
May 16, 2014
If the user interface cable has been connected to the user system, FAIL is displayed on the screen (see figure
below). Correctly connect the cable to the self-checking connector and click on the [START] button again to start
the self-checking program.
Figure A.5 [FAIL] at the Start of Self-Checking
(with the Cable Connected to the User System)
If the USB interface cable has been disconnected from the emulator, FAIL is displayed on the screen (see figure
below). Correctly connect the cable and click on the [START] button again to start the self-checking program.
Figure A.6 [FAIL] on Error with USB I/O Processing
-
8/10/2019 R0E000010KCE00 emulador renessas
34/39
E1/E20 Emulator Appendix A
R20UT0398EJ0400 Rev.4.00 Page 34 of 39
May 16, 2014
(3) As soon as the self-checking program is started.
TEST1 is running. and TEST2 is running. are shown on the screen. If the emulator correctly completes TEST1
and TEST2, TEST1: PASS and TEST2: PASS are displayed.
Figure A.7 Running the Self-Checking Program
(4) When TEST3 is entered, the following message appears.
Please remove the User interface cable from the self-checking connector to execute TEST3.
After this message has been displayed, disconnect the user interface cable from the self-checking connector and
close the lid of the self-checking connector. Then click on the [OK] button to continue with the self-checking
process.
If the user interface cable is still connected to the self-checking connector or user system, clicking on the [OK]
button does not restart the self-checking process.
Figure A.8 Message [Please remove the User interface cable from
the self-checking connector to execute TEST3.]
-
8/10/2019 R0E000010KCE00 emulador renessas
35/39
E1/E20 Emulator Appendix A
R20UT0398EJ0400 Rev.4.00 Page 35 of 39
May 16, 2014
If you click on the [Cancel] button, FAIL is displayed on the screen (see figure below). Correctly connect the
cable to the self-checking connector and click on the [START] button again to start the self-checking program.
Figure A.9 [FAIL] Display that Appears When [Cancel] is Clicked on
(5) As soon as the self-checking program is started.
TEST3 is running. appears on the screen and self-checking continues.
PASS or FAIL appears after TEST3 is completed.
PASS indicates no problems with the emulator.
Click on the [QUIT] button to end the self-checking program.
Figure A.10 Normal Completion of Self-Checking
-
8/10/2019 R0E000010KCE00 emulador renessas
36/39
E1/E20 Emulator Appendix A
R20UT0398EJ0400 Rev.4.00 Page 36 of 39
May 16, 2014
In the case of failure, the word FAIL is displayed, followed by an error message in the center of the window.
Table A.1 lists the error messages.
Figure A.11 Display for an Error Found in Self-Checking
Clicking on the [LOG] button opens the file selection dialog box. Specify the location where you want the results
of self-checking to be saved. The results of self-checking are saved as a text file.
Table A.1 Error Messages
Message Description
The E1/E20 self-check has failed. The user interface cable was connected to the user system at
the time the self-checking program was started or there is a
fault in the emulator.
If the fault falls under the warranty conditions given in section 7,
Maintenance and Warranty, we will correct the fault or replacethe product for free. Correction or replacement in other cases
incurs a fee.
Please connect the user interface cable with
the self-check connector in a correct direction.
Correctly connect the user interface cable to the self-checking
connector before starting the self-checking program.
An error occurred during USB I/O processing. The USB interface cable was disconnected from the emulator
during self-checking or there is a fault in the emulator. Connect
the USB interface cable and restart the self-checking program.
If the error recurs, it is due to a fault in the emulator.
If the FAIL is displayed in the other error, please request the repair because the product is defective.
-
8/10/2019 R0E000010KCE00 emulador renessas
37/39
-
8/10/2019 R0E000010KCE00 emulador renessas
38/39
http://www.renesas.comRefer to "http://www.renesas.com/" for the latest and detailed information.
Renesas Electronics America Inc.2801 Scott Boulevard Santa Clara, CA 95050-2549, U.S.A.Tel: +1-408-588-6000, Fax: +1-408-588-6130
Renesas Electronics Canada Limited1101 Nicholson Road, Newmarket, Ontario L3Y 9C3, CanadaTel: +1-905-898-5441, Fax: +1-905-898-3220
Renesas Electronics Europe LimitedDukes Meadow, Millboard Road, Bourne End, Buckinghamshire, SL8 5FH, U.KTel: +44-1628-585-100, Fax: +44-1628-585-900
Renesas Electronics Europe GmbH
Arcadiastrasse 10, 40472 Dsseldorf, GermanyTel: +49-211-6503-0, Fax: +49-211-6503-1327
Renesas Electronics (China) Co., Ltd.Room 1709, Quantum Plaza, No.27 ZhiChunLu Haidian District, Beijing 100191, P.R.ChinaTel: +86-10-8235-1155, Fax: +86-10-8235-7679
Renesas Electronics (Shanghai) Co., Ltd.Unit 301, Tower A, Central Towers, 555 Langao Road, Putuo District, Shanghai, P. R. China 200333Tel: +86-21-2226-0888, Fax: +86-21-2226-0999
Renesas Electronics Hong Kong LimitedUnit 1601-1613, 16/F., Tower 2, Grand Century Place, 193 Prince Edward Road West, Mongkok, Kowloon, Hong KongTel: +852-2265-6688, Fax: +852 2886-9022/9044
Renesas Electronics Taiwan Co., Ltd.13F, No. 363, Fu Shing North Road, Taipei 10543, TaiwanTel: +886-2-8175-9600, Fax: +886 2-8175-9670
Renesas Electronics Singapore Pte. Ltd.80 Bendemeer Road, Unit #06-02 Hyflux Innovation Centre, Singapore 339949Tel: +65-6213-0200, Fax: +65-6213-0300
Renesas Electronics Malaysia Sdn.Bhd.Unit 906, Block B, Menara Amcorp, Amcorp Trade Centre, No. 18, Jln Persiaran Barat, 46050 Petaling Jaya, Selangor Darul Ehsan, MalaysiaTel: +60-3-7955-9390, Fax: +60-3-7955-9510
Renesas Electronics Korea Co., Ltd.12F., 234 Teheran-ro, Gangnam-Ku, Seoul, 135-920, KoreaTel: +82-2-558-3737, Fax: +82-2-558-5141
SALES OFFICES
2014 Renesas Electronics Corporationand
Renesas Solutions Corp. All rights reserved.
Colophon 3.0
-
8/10/2019 R0E000010KCE00 emulador renessas
39/39
E1 Emulator R0E000010KCE00E20 Emulator R0E000200KCT00Users Manual