Quick Installation Guide EPS Box - SolaX Power
Transcript of Quick Installation Guide EPS Box - SolaX Power
EPS BoxQuick Installation Guide
1. Introduction
2. Overview
3. Preparation
3.1Packing List Checking
expansion tubes X 4
cushion blocks X 4
self-tapping screws X 4
cold pressedterminals X8
„‚ ƒ …
Before installation, make sure that nothing inside the package is damaged. The following items should be inside the package.
Diagonal plier Screwdriver Manual wrench
Φ6 driller Rubber hammer
Before you start, get the following tools ready.3.2 Tools
Marker pen
EPS Box integrates two contactors which provides simple connection for users. It is compatible with X-hybrid E Series inverter. Configured with EPS Box, customers just need to connect 6 wires between inverter and EPS Box. It can simplify the operation and improve security.
expansion screws X 4
01
4. Mounting
Step 1:Install the four cushion blocks on EPS Box with self-tapping screws.
cushion blocks
self-tapping screws
Step 2:
mark position
Use EPS Box with cushion blocks as a template to mark the four holes’ position on the wall with marker pen.
02
-Drill holes with 6 drillΦ-Depth : at least 50mm
-Τighten the expansion tubes
Drill holes with Φ6 driller carefully, make sure the holes are deep enough for installing. Install the expansion tubes through cushion blocks into the holes and tighten them.
Install the expansion screws with screwdriver to fix the EPS Box.
Step 3:
Step 4:
EPS Box
EPS Load
300m
m
220mm
170m
m
1
2
3
EPS
Load
Grid
Object Description
614.00078.03
6. Technical Parameters
Grid
Max.AC input current (A)
Rated AC voltage ( V )
Rated AC frequency (Hz)
EPSMax.EPS input current (A)Rated EPS voltage ( V )Rated EPS frequency (Hz)
63
230
50 / 60
32230
50 / 60
Load
Genaral DataOperating Temperature range (℃ )Dimension (mm)Weight (kg)
Rated output current(A),on grid modeRated output current(A),EPS modeRated Grid Voltage( V )
6332
230
300*220*1703.5
-10~+50
Rated Grid Frequency(Hz) 50/60
0403
Overview of EPS Box
5. Wiring Connection
15mm
15mm
� ‚ ƒ
5.1 Wires making
Wires below are needed before installation.
Use the diagonal plier to trip 15mm of insulation from side of the wire as below.
Insert this end of wire into cold pressed terminal and tighten it.
5.2 Grid-Wires ConnectionUse the manual wrench to screw off the cap on cable nut, and then insert Grid-L wire and GRID-N wire into the ports of contactor (A&B) through the cable nut and tighten them with screwdriver.
Please prevent other wires from getting loose during operation.
Use the manual wrench to screw off the cap on cable nut, and then insert Load-L wire and Load-N wire into ports of contactor (C&D) through the cable nut and tighten them with screwdriver.
5.3 Load-Wires Connection
Use the manual wrench to screw off the cap on cable nut, and then insert EPS-L wire , EPS-N wire and GND-wire into ports of contactor (E&F) through the cable nut and tighten them with screwdriver.
Please make sure all wires are tightened.Wire connection in EPS-Box 5.6 Checking
5.4 EPS-Wires Connection
GND wire*1 For EU
15mm
GND
10AWG N wire*1 For AU
15mm 15mmFor EU
For AU
1 pcs
2 pcs
4 pcs
1 pcs
Use the manual wrench to screw off the cap on cable nutIn EU, insert GND-wire into port of contactor (F) through the cable nut and tighten it with screwdriver.In AU, insert N wire into ports of contactor(B&F) .
5.5 Wires Connection
For EU For AU
upside
Grid-L wire
Grid-N wire
downside
A
B
cable nut
Load-L wire —— C Load-Nwire —— D Load-L/N�wire~5AWG
Grid-L�wire —— AGrid-Nwire —— BGrid-L/N�wire~5AWG
EPS-L�wire —— EEPS-Nwire —— F EPS-L/N�wire~10AWG
cable nutC
D
Load-L wire Load-N wire
cable nut
EPS-L wire EPS-N wire
GND wire
For EU For AU
N wire
For EU
to GRIDto Load
to EPS port of inverter to E-BAR –
For AU
to GRIDto Load
to EPS port of inverter
Left View
EFLeft View
AB
CD
Left View
F
Left View
B