Installation, Operation and Maintenance Instructions
– Read and Save These Instructions –
This manual is provided to acquaint you withthe desiccant dehumidifier so that installation,operation and maintenance can proceed suc-cessfully. Ultimate satisfaction depends on thequality of installation and a thorough under-standing of this equipment. The dehumidifieris built around tested engineering principlesand has passed a thorough inspection forquality of workmanship and function.
Installation, Operation and Maintenance Instructions
4201 Lien Rd. Phone 608-237-8400Madison, WI 53704 Toll-Free 1-866-933-7486www.QuestProtect.com [email protected]
– Read and Save These Instructions –
TS-576
02/161
Quest PowerDry 4800D Pro E:
• 3032 Pints/day AHAM• 4800CFMprocessairflow• Dries in temperatures to 140°F•Reachesdewpointsaslowas-40°F• 48”W x 120”L x 74”H•1600lbs.(Standardmachineweightonly)•480volt3-phase
• 106fullloadamps
Quest DRY 150Quest PowerDry 4800D Pro E
QuestPowerDry4800DPro E (withoutFrame)
PN 4029193
questquest
QuestPowerDry4800DProE(withFrame)
PN 4028203
Water Removal Rates (Pints/Day)
3032 Pints 80˚F, 60% (AHAM)
questquest
Quest PowerDry 4800D Pro E Installation, Operation and Maintenance Instructions
2www.QuestProtect.com
Table of Contents
SafetyPrecautions.............................................3
1. Specifications..............................................4
2. Operation...................................................5
2.1HowtheQuestDry
PowerDry4800DProEWorks...................5
3. Installation..................................................5
3.1Inspection.............................................6
3.2Location................................................6
3.3Set-Up..................................................6
3.4Ducting.................................................6
3.5AvoidingSecondarydamage.................7
3.6ElectricalRequirements.........................7
4. OperationInstructions.................................7
4.1ConnectandStart-UpProcedure...........8
4.2CoolDown...........................................8
4.3ShutDownandDisconnectProcedure..8
5. ControlPanel..............................................8
5.1MainDisconnect..................................8
5.2StandbyLight........................................8
5.3PhaseOut.............................................9
5.4SelectorSwitch.....................................9
5.5Alarm....................................................9
5.6HourMeter...........................................9
6. Maintenance...............................................9
6.1GeneralMaintenance............................9
6.2Cabinet...............................................10
6.3Filter...................................................10
6.4BlowerandMotor...............................10
6.5DriveMotor........................................10
6.6RotorDriveChain...............................10
6.7Seals...................................................10
6.8DesiccantMedia.................................11
7. PanelLayout/WiringDiagram....................12
8. TroubleShooting.......................................15
9. DetailedSequenceofEvents-
ControlOperation.....................................16
10. ServiceParts..............................................17
Warranty...................................................18
SerialNo.__________________________________
PurchaseDate_____________________________
Dealer’sName_____________________________
Read the operation and maintenance instructions carefullybeforeusingthisunit.ProperadherencetotheseinstructionsisessentialtoobtainmaximumbenefitfromyourQuestPowerDry4800DProE.
Quest PowerDry 4800D Pro E Installation, Operation and Maintenance Instructions
3www.QuestProtect.com
questquest1-866-933-7486
Safety PrecautionsReadtheinstallation,operationandmaintenanceinstructionscarefullybeforeinstallingandoperating thisdevice.Properadherencetotheseinstructionsisessentialtoobtainmaximumbenefitfromyour QuestPowerDry4800DProE.
questquest
Quest PowerDry 4800D Pro E Installation, Operation and Maintenance Instructions
4www.QuestProtect.com
Quest PowerDry 4800D Pro E Installation, Operation and Maintenance Instructions
4
1. SpecificationsPart No. 4028203 (with Frame)
Part No. 4029193 (without Frame)
Power 480 VAC, 3-Phase, 106 FLA
Water 3032 pints/day @ AHAM Removal
Blower 4800 CFM Process Air Flow 2000 CFM Reactivation Air Flow
Operating -10ºF to 140ºF Range
Filters Processfiltersize:(2)20”x20”x2” Reactivationfiltersize:(1)20”x20”x2”
Duct Options Processinlet/outlet-18”HeavyDutyPVCminimum,20”HeavyDutyPVCrecommended Reactivation-18”HeavyDutyPVCminimum,20”HeavyDutyPVCrecommended
Warranty 2years: 1st year Parts and Service 2nd year Silica Gel Rotor
*Low temperature performance is dependent on reactivation air source. Supplying warmer reactivation air will significantly increase water removal.
Dimensions
Unit Width 48” Height 74” Length 120” Weight 1600 lb
Accessories
4028361 10”Flex-Duct
4028364 18”x25’,6”Pitch,HeavyDutyPVC/PolyesterDuct
4028374 18”LayFlatDuct
4035579 20”x25’,4”Pitch,HeavyDutyPVC/PolyesterDuct
4024440 Kestrel 3000 Multi-Function Air Meter
4027327 ExternalTemperaturecontrol
4020175 ExternalDehumidistat
4029003 Power Cord Grip
Air Filter Replacement
4028635 20”x20”x2”Filter
Quest PowerDry 4800D Pro E Installation, Operation and Maintenance Instructions
5www.QuestProtect.com
questquest1-866-933-7486
Quest PowerDry 4800D Pro E Installation, Operation and Maintenance Instructions
5
2. OperationThefunctionofthedehumidifieristoremovemoisture(inthevaporstate)fromanairstream.Thisisaccomplishedbyexposingtheairtoanadsorbingmedia(desiccant)inasealedairstream(process).Afterthedesiccanthasadsorbedmoisture,itisexposedtoasecondairstreamatanelevatedtemperature(reactivation).Thiscausesthemoisturetobedrivenoutofthedesiccantpreparingitformoremoistureadsorption.Thisprocessisdoneonacontinuousbasis,providingaconstantdryingprocess.Thetwoairstreams(processandreactivation)areseparatedbyseals,whichcontactthedesiccantmedia.Figure1illustratestherelationshipofthesealsandairflowpattern.Thedehumidifierisdesignedwiththetwoairstreamsflowinginoppositedirections(counterflow)therebymaximizingtheenergyefficiencyoftheequipment.
2.1 How the Quest PowerDry 4800D Pro E WorksTheQuestPowerDry4800DProEhastwoseparateairstreamsthatrunthroughit–ProcessandReactivation(Fig.1).
Process Air Stream:
P1–4800CFMofairentersthemachine(ProcessAirInlet)and...
P2–...watervaporfromincomingairisdeposited(adsorbed)onthedesiccantwheel.
P3–4800CFMofdryairexitsthemachine(ProcessAirOutlet).
Reactivation Air Stream:
R1–2000CFMofairentersthemachine(ReactivationAirInlet)and...
R2–passesovertheheatercoils.
R3–Watervaporispickedup(desorbed)fromthedesiccantwheelbythehotairand...
R4–...2000CFMofwetairexitsthemachine(ReactivationAirOutlet).
3 InstallationProperinstallationiscriticaltotheperformanceoftheQuestPowerDry4800DProE.Followtheguidelinesbelowtomaximizeservicelifeandperformance.
Cabinet Divider and Seals
Reactivation Air Outlet
Process Air Inlet
Heater
Principle of Operation
Process Air Outlet
Desiccant Wheel
Desiccant WheelDrive and Chain
Reactivation Air Inlet
questquest
Quest PowerDry 4800D Pro E Installation, Operation and Maintenance Instructions
6www.QuestProtect.com
3.1 InspectionThoroughlyinspectthemachinetoinsurenodamagehasoccurredduringshippingoronthejobsite.
3.2 LocationNote the following precautions when locating the Quest PowerDry 4800D Pro E:
ThePowerDry4800DProEisdesignedtobeusedindoorsoroutdoors.
Ifthehumidareaisverylarge,dehumidificationcanbeimprovedbyaddinganoutletducttocirculateprocessairtostagnantareas.
3.3 Set-UpWhenconditionswarranttheuseofadesiccantdehumidifier,useoneofthesetupsdescribedbelowtoachieveefficientdrying,whileavoidingsecondarydamage.ReviewSection2.1tounderstandthedesiccantdryingprocess.AlwaysensurethattheReactivationOutletductisventedtotheoutdoorstominimizethepossibilityofsecondarydamage.
Neutral Pressure Setup
Manydryingapplicationsrequireneutralpressureoperation.Inthissetup,theProcessAirInletpullsairfromtheaffectedarea(dryingchamber)andreturnsdried,processedairtotheaffectedareaviatheProcessAirOutlet.
TheReactivationAirInletandOutletarebothductedtotheoutdoors(orleftopeniftheunitissetupoutside).
Positive Pressure Setup
ForPositivePressureoperation,theProcessAirInletpullsairfromoutsidethedryingchamber,whiletheProcessAirOutletisductedintothechamber.
3.4 DuctingTheductrequirementsofthePowerDry4800DProEaremuchmorecriticalthanthoseofrefrigerant-baseddehumidifiers.ALL SUPPLY AND RETURN AIR DUCTING FOR THE PowerDry 4800D Pro E MUST BE AIR AND VAPOR TIGHT.Thisisextremelyimportantforproperperformance.Ensurethatreactivationdischargeairdoesnotentertheprocessorreactivationinlets.
Usingexcessductlengthsignificantlyreducesairflowvolumethroughduct.Thisistrueinanyapplication.Ifthejobathandneedsashortlengthofduct,cutasectiontotheappropriatelength.Ifairflowisrestrictedbyexcesslength,performancewillsuffer.Thesamecanbesaidofexcessbendsintheducting.
TwodifferentductsizesareusedonthePowerDry4800DProE.AllductingmaterialsareavailablefromTherma-StorLLC (seeaccessorieslistinSection1).
Process inlet / Reactivation inlet: 18” flex duct.
Toattachflexductstotheprocessairintake,pushthewireofthefirstfewloopsbeyondthe2holesintheductcollar.Pushthemetalrodthroughtheductandductcollarpiercingtheductintwoplaces.Tapeorahoseclampcanbeusedtocreateanairtightseal.Alternatively,theductwirecanbepushedpasttheweldbeadsontheductcollarandtheductcanbesecuredwithhoseclampsorratchetingstraps.Ifusingonlyoneinletconnection,theothercanbeleftclosed.
Process outlet: 18” flex or lay flat plastic duct.
Toattachflexductstotheprocessairoutlet,pushthewireofthefirstfewloopsbeyondthe2holesintheductcollar.Pushthemetalrodthroughtheductandductcollarpiercingtheductintwoplaces.Tapeorahoseclampcanbeusedtocreateanairtightseal.Alternatively,theductwirecanbepushedpasttheweld
Quest PowerDry 4800D Pro E Installation, Operation and Maintenance Instructions
7www.QuestProtect.com
questquest1-866-933-7486
beadsontheductcollarandtheductcanbesecuredwithhoseclampsorratchetingstraps.
Whenusing18”layflatducting,slipovertheoutletcollarandzip-tieorducttapeinplace.
Reactivation outlet: 10” flex duct or lay flat.
Toattachflexducttothereactivationairoutlet,pushthewireofthefirstcoupleofloopsbeyondtheweldbeadsonanoutletcollar.Securewithhoseclamp.
3.5 Avoiding Secondary DamageTheQuestPowerDry4800DProEisapowerfultoolcapableofremovingagreatdealofwaterfrommostenvironments.Caremustbetakentoavoidsecondarydamageofover-dryingandorunexpectedcondensation.
TheQuestPowerDry4800DProEremovesvaporwaterfromtheincomingprocessairstreamandtransfersittotheoutgoingreactivationairstream.Thereactivationexhaustairishotandwet.
Takecaretopreventthereactivationexhaustairstreamfromcausingsecondarydamageduetocondensation.AlwaysensuretheQuestPowerDry4800DProEislocatedwiththereactivationoutletpointedsuchthatreactivationairwillNOTbedrawnbackintothestructure.
TheQuestPowerDry4800DProEdoesnotproduceliquidwaterinternaltothemachine.Thereisnocondensatepumpandnodrainhose.
TheQuestPowerDry4800DProEdesiccantdehumidifierwillcontinuetoremovewaterfromalreadydry,coldair.Itispossibletoover-dryobjectsandorstructures.
Caremustbetakentoavoidsecondarydamageduetoover-drying.
3.6 Electrical RequirementsA480volt,3phasepowersourceisrequiredtooperatetheQuestPowerDry4800DProE.
Alllocalandstatecodesmustbestrictlyadheredtoandgoodelectricalpracticesshouldbefollowedtoachievethebestinstallationpossible.ThePowerDry4800DProEmustbeproperlywiredtoanadequatepowersource.Seriousdamagetothemotorsandcontrolscanoccurifincorrectvoltageisapplied.
(SeeElectrical Schematicdrawinginthebackofthismanualforinternalwiring.)
4 Operating InstructionsRefertotheOperatingInstructionslabellocatednexttothecontrolpanelofyourPowerDry4800DProE.
User-suppliedpowercord,cordgrip,andbranchprotectionappropriatefortheelectricalloadmustbesupplied.SeedeviceforFLArating.
TheQuestPowerDry4800DProEdehumidifiercomescompleteandreadyforoperation.Allthatisrequiredistoprovidetheproperpowersource,propanesupply,andductconnections(describedabove).
questquest
Quest PowerDry 4800D Pro E Installation, Operation and Maintenance Instructions
8www.QuestProtect.com
4.1 Connect and Start-Up Procedure1. LockoutPowerSource.
2. Wireunit480Volt3Phase.
3. VerifySelectorSwitchissettoSTANDBY.
4. EngagePowerSourceandturnMainDisconnecttoON.
5. VerifyPHASEOUTlightisoff,ifnot,re-wirepowersourcetocorrectphaseorder.
6. COOLDOWNlightwillcomeonfor5minutes.
7. SetSelectorSwitchtoRUN.
8. Setprocessdampertoobtainamaximumof1.5”watercolumnpressureasreadonpressuregauge.
4.2 Cool Down1. SetSelectorSwitchtoSTANDBY.
2. COOLDOWNlightwillcomeonfor5minutes.
3. WhenCOOLDOWNlightisoff,MainDisconnectcanbe switchedtoOFF.
FailuretofollowCOOL DOWN PROCEDUREmayresultindamagetounitduetooverheating.ALWAYS followCOOL DOWN PROCEDUREbeforeshuttingunitdown.
4.3 Shut Down & Disconnect Procedure 1. VerifyCOOLDOWNlightisnotilluminatedandCoolDownProcedurehasbeenfollowed.
2. TurnMainDisconnectSwitchtoOFF.
3. DisengagePowerSource.
4. LockOutPowerSource.
5. DisconnectPowerCable.
5 Control Panel5.1 Main DisconnectThemaindisconnectswitchespowerfromthesourcetothepanel.Powermustbedisconnectedatthesourcepriortoaccessingcontrolpanel.AccesstothecontrolpanelwithpowerappliedisONLYbyqualifiedservicepersonnelwiththeappropriatepersonalprotectiveequipment PowerispresentuptodisconnecteveninOFFposition.Disconnectpoweratthesourcebeforeopeningpanel.
5.2 Standby LightTheSTANDBYindicatorlampilluminatestoindicatethatpowerissuppliedtothecontrolpanel.
Quest PowerDry 4800D Pro E Installation, Operation and Maintenance Instructions
9www.QuestProtect.com
questquest1-866-933-7486
5.3 Phase OutThePHASEOUTindicatorlampilluminatestoindicatethatthe3-phasepowerisnotcorrectlywiredintothepowersupply.Changethewiringatthepowersupplyconnectiontocorrectthephaseorder.
5.4 Selector SwitchWhentheselectorswitchismovedtothe“RUN”position,thePowerDry4800DProEstartsdehumidifying.Themachinewillcontinuetodehumidifyinallconditionsuntilthepoweristurnedoff.Nodehumidistatisprovidedtomonitorprocessinletaircondition(seeover-drywarningsection3.5).Anexternalcontrol(dehumidistat,thermostatorothercontact)canbewiredinplaceofthejumperacrossterminals3040and3042.Theexternalcontrolmustbedesignedtooperatea115VACcircuit. ThePowerDry4800DProEhasonecontroldevice,thepowerswitch.Whenthepowerswitchismovedtothe“on”positionyourportabledesiccantisdehumidifying.Themachinewillcontinuetodehumidifyinallconditionsuntilthepoweristurnedoff:Thereisnodehumidistat(seeover-drywarningsection2.2).
5.5 Alarm (Light and Horn)Thealarmindicatorlampilluminates(andhornsounds)toindicatethatafaultconditionexists.Thefaultconditionscouldbe:
•MotorOverload(processorreactivation)
•ReactivationTemperaturegreaterthan375°F
•Nodehumidification(i.e.saturatedwheel)
•Lowreactivationairflow
•Stuckheatercontactor
Anexternalalarmcanbewiredtoterminals3080(power)andX2(neutral).Thiswouldsupply115VACduringanalarmcondition.
5.6 Hour MeterThehourmeterwillrunwheneverthePowerDry4800DProEisoperating.Thishourmetermeasuresthecumulativetimeofoperationinone-tenthhourincrements.Thismeterisoftenusedtoverifyhoursonajobortoschedulemaintenance.
6 Maintenance6.1 General MaintenanceAdefinitivetimescheduleshouldbeestablishedforinspectingallrotatingpartsandcomponents.Inspectionrequirementsdependonthefrequencyofoperation,transport,andoperatingconditions.Periodicallychecktheconditionoftheairfilter,rotatingparts,andfastenerstoensuretheyaresecureandinproperworkingorder.Periodicallycheckairflowtomakesuretherearenoobstructionstoairflowinoutletorinletductwork.
Recommendedminimuminspections:
•Uponinstallation
•After1weekofoperation.
•Annuallythereafteroruponlossofperformance.
questquest
Quest PowerDry 4800D Pro E Installation, Operation and Maintenance Instructions
10www.QuestProtect.com
6.2 Cabinet
Disconnect power before removing access panels.
Removepanelfastenersandpanelsfromunittoaccessinternalcomponents.Theconditionofthecabinetgasketsshouldbeobservedduringinspectionandservicingtoinsureagoodseal.Anyleaksmustbesealedandpanelssecurelyfastenedforproperdehumidifieroperation.
6.3 FilterThemaintenanceintervalforthefilterdependsdirectlyonthecleanlinessoftheairenteringthedehumidifier.Itissuggestedthataprogrambeestablishedtoassurethatthefiltersarereplacedorcleanedpriortobecomingcloggedtothepointtheycreateasystemproblem.
Threealuminum(20”x20”x2”)airfiltersmustbecheckedregularly.Twofiltersarelocatedneartheprocessairinlet.Theotheroneislocatednearthereactivationairinlet.
Washthefilterswithfreshwater.Cleanthefilterfromthedownstreamside,forcingdebristowardthefilterinlet.Drythefilterscompletelybeforeinstallingtheminunit.Replacementfilterscanbeorderedfromthefactoryorpurchasedlocallyifavailable.
DO NOToperatetheunitwithoutthefiltersorwithlesseffectivefiltersasthedesiccantwheelinsidetheunitwillbecomecloggedandrequiredisassemblytoclean.
6.4 Blower and MotorBlowerandmotorbearingsarepermanentlylubricatedanddonotrequiremaintenance.Blowerwheel-inspectwheelbladesforaccumulationofdustanddirt.Cleanthoroughlywithcompressedairandorvacuum.Thewheelshouldnotstrikethehousingortheinletring.Makesurewheelisrotatingintheproperdirection.
6.5 Drive MotorThemediadrivemotorispermanentlylubricatedandrequiresnomaintenance.
6.6 Rotor Drive ChainAspringloadedtensionerkeepsthechainsufficientlytensioned.Checkthechainforsignsofexcessivewear.Replaceasnecessary.Ifadditionaltensionisrequired,simplytightenthenutsonthetensionspringsasrequired.
6.7 SealsHightemperaturesealsseparatetheprocessandreactivationcompartments.Normally,thesealswillnotrequireserviceorreplacement.However,shoulddamageoccur,orifpoorperformanceastheresultofanairleakissuspected,thefollowinginspectionmustbeperformedtodeterminewhetherthesealsshouldbereplaced:
Inspection:
1) Turntheunitoffandremovetheaccesscovers.
2) Visuallyinspectforgapsbetweenthedesiccantmedia
andtheseals.
3) Ifsignificantgaps,wear,ordamageareobserved, thesealneedstobereplaced.
Quest PowerDry 4800D Pro E Installation, Operation and Maintenance Instructions
11www.QuestProtect.com
questquest1-866-933-7486
6.8 Desiccant MediaThesilicageldesiccantmediasuppliedwiththedehumidifierwilllastindefinitelyunderidealconditions.Duetothenatureofdesiccantstheymakeverygoodfilters.Thelifeofthedesiccantisdirectlyrelatedtotheairbornecontaminatespassedthroughit.Atmosphericcontaminants,exposuretoacidicgases/orairstreams,andcontactwithpetroleumbasedairborneparticlescanreducetheefficiencyofthedesiccantmedia.Thepreferredmethodofcleaningistoblowdustoutwithcompressedair.Properfiltrationandpreventingcontactwithchemicalswillgreatlyimprovethelifeofthedesiccant.Inspectthefaceofthemediatoseethatnosurfacedamagehasoccurred.Ifdamageisnoticed,pleasecontactTherma-Storat1-800-533-7533forassistance.Therotorshouldturnsmoothlyupontheshaft,ifnotcheckthesupportbearings.
Servicing the Quest PowerDry 4800D Pro E with its high voltage circuitry presents a health hazard which could result in death, serious bodily injury, and/or property damage. Only qualified service people should service this unit.
ELECTRICAL SHOCK HAZARD: Electrical power must be present to perform some tests; these tests should be performed only by a qualified service person.
questquest
Quest PowerDry 4800D Pro E Installation, Operation and Maintenance Instructions
12www.QuestProtect.com
7 Panel Layout/Wiring Diagram
Quest PowerDry 4800D Pro E Installation, Operation and Maintenance Instructions
13www.QuestProtect.com
questquest1-866-933-7486
L1 L2
L1 L2 L3
1T2
1T3
1T1
FIELD DETERMINE
L1
L2
L3
1L1
1L2
1L3
#8 AWG PER PHASETYPE MTW
1CB90 DEG C COPPER
480V 3Ø 60HZ
LL1 LL2 LL3
INCOMING POWER
GND
200 AMPNON-FUSED DISCONNECT POWER DISTRIBUTION
40A
24 KW28.9FLA
HEATER A
BRANCH PROTECTION SUPPLIED
HAR
#8 AWG PER PHASETYPE MTW90 DEG C COPPER
105 FLALARGEST MOTOR 7.5HPLARGEST HEATER 24KW
2T2
2T3
2T1
FIELD DETERMINE
L1
L2
L3
2L1
2L2
2L3
#8 AWG PER PHASETYPE MTW
2CB90 DEG C COPPER
40A
24 KW28.9FLA
HEATER B
HBR
#8 AWG PER PHASETYPE MTW90 DEG C COPPER
3T2
3T3
3T1
FIELD DETERMINE
L1
L2
L3
3L1
3L2
3L3
#8 AWG PER PHASETYPE MTW
3CB90 DEG C COPPER
40A
24 KW28.9FLA
HEATER C
HCR
#8 AWG PER PHASETYPE MTW90 DEG C COPPER
4T2
4T3
4T1
FIELD DETERMINE
L1
L2
L3
4L1
4L2
4L3
PMS
#14 AWG PER PHASETYPE MTW
OLR-P90 DEG C COPPER
7.5HP3600 RPM
PROCESS MOTOR
PMS
#14 AWG PER PHASETYPE MTW90 DEG C COPPER
10.9FLA
5T2
5T3
5T1
FIELD DETERMINE
L1
L2
L3
5L1
5L2
5L3
RMS
#14 AWG PER PHASETYPE MTW
OLR-R90 DEG C COPPER
5HP3600 RPM
REACTIVATION MOTOR
RMS
#14 AWG PER PHASETYPE MTW90 DEG C COPPER
6.1FLA
XFMR350VA
480VAC
X1 X2
H1 H4
XL1
120VAC1 2
L1
L2
1
H3 H2#14 AWG MTW WHITE#14 AWG MTW RED
#14 AWG MTW GRN/YEL
TO SHEET 3 OF 3 TO SHEET 3 OF 3
XL2
#14 AWG PER PHASETYPE MTW90 DEG C COPPER
(6.3-9.0A)
FU1
FU2
2A
FU3
4A
PHASE
L1
L2
L3
#14 AWG PER PHASETYPE MTW90 DEG C COPPER
MONITOR
**(BY OTHERS)**
SET AT 6.3A
(9.0-12.5A)SET AT 10.9A
4
3
5
questquest
Quest PowerDry 4800D Pro E Installation, Operation and Maintenance Instructions
14www.QuestProtect.com
9 Troubleshooting
Trouble Probable Fault Probable Cause Corrective Action 1. Main power off Check main power and cable 2. Main disconnect open Close or replace disconnect 3. Selector switch open Close or replace switch
Unit Stopped (fan off, no heater)
Power/Control Failure
4. Dehumidistat Repair or replace 1. Motor circuit breaker or
overload tripped Reset circuit breaker or overload
2. Contactor failure Repair or replace 3. Motor winding failure Repair or replace
Fan off (Rotor turns)
Power/Mechanical Failure
4. Fan motor failure Repair or replace 1. Excessive unconditioned make-
up air Reduce make-up air
2. Leaking ducts or air handling equipment outside controlled area
Seal leaks
3. Access opening to area not sealed
Close and seal
Excessive infiltration of humid air into the controlled area
4. Area not vapor tight Seal with paint or vapor barrier 1. Dehumidistat needs
adjustment Re-adjust
2. Improper settings Re-adjust
Faulty humidity controls
3. Defective Replace 1. Dirty filter Clean or replace 2. Obstruction at inlet, outlet or
ducting Remove obstruction
Inadequate air flow
3. Clogged desiccant media (high pressure differential across media)
Remove and replace media rotor
1. Element failure Check elements – repair or replace
2. Low / no voltage Correct power supply / breakers
Inadequate or no reactivation heat
3. Control elements failure Control set point / repair or replace
1. Air leaking into dehumidifier Replace access door gaskets Air seals and gaskets 2. Air bypassing media or leaking
seals Check media position, replace seals
1. Chain Repair or replace 2. Motor/gear box Repair or replace 3. Damaged desiccant rotor Repair or replace
Unit running but humidity rises
Ineffective desiccant media
4. Contaminated or damaged desiccant
Replace desiccant rotor
Quest PowerDry 4800D Pro E Installation, Operation and Maintenance Instructions
15www.QuestProtect.com
questquest1-866-933-7486
9 Troubleshooting
Trouble Probable Fault Probable Cause Corrective Action 1. Main power off Check main power and cable 2. Main disconnect open Close or replace disconnect 3. Selector switch open Close or replace switch
Unit Stopped (fan off, no heater)
Power/Control Failure
4. Dehumidistat Repair or replace 1. Motor circuit breaker or
overload tripped Reset circuit breaker or overload
2. Contactor failure Repair or replace 3. Motor winding failure Repair or replace
Fan off (Rotor turns)
Power/Mechanical Failure
4. Fan motor failure Repair or replace 1. Excessive unconditioned make-
up air Reduce make-up air
2. Leaking ducts or air handling equipment outside controlled area
Seal leaks
3. Access opening to area not sealed
Close and seal
Excessive infiltration of humid air into the controlled area
4. Area not vapor tight Seal with paint or vapor barrier 1. Dehumidistat needs
adjustment Re-adjust
2. Improper settings Re-adjust
Faulty humidity controls
3. Defective Replace 1. Dirty filter Clean or replace 2. Obstruction at inlet, outlet or
ducting Remove obstruction
Inadequate air flow
3. Clogged desiccant media (high pressure differential across media)
Remove and replace media rotor
1. Element failure Check elements – repair or replace
2. Low / no voltage Correct power supply / breakers
Inadequate or no reactivation heat
3. Control elements failure Control set point / repair or replace
1. Air leaking into dehumidifier Replace access door gaskets Air seals and gaskets 2. Air bypassing media or leaking
seals Check media position, replace seals
1. Chain Repair or replace 2. Motor/gear box Repair or replace 3. Damaged desiccant rotor Repair or replace
Unit running but humidity rises
Ineffective desiccant media
4. Contaminated or damaged desiccant
Replace desiccant rotor
8 Troubleshooting
questquest
Quest PowerDry 4800D Pro E Installation, Operation and Maintenance Instructions
16www.QuestProtect.com
10 Detailed Sequence of Events – Control Operation1. TurningonMainDisconnectatdehumidifierprovides480VAC,3phasepowertothecontrolpanel.
Powerisdistributedtobreakersforblowermotors,heatersandthecontroltransformer.Thecontroltransformersupplies115VACforcontrolsystemanddesiccantwheelmotor.PHASEOUTlamp,ifilluminated,indicatesthepowersupplyisnotconnectedcorrectly.Rewirepowersupplyasneeded.
a. STANDBYlampilluminates.
b. Rotormotorterminals,3470andX2,energizeprovidingthedesiccantmotorwith115VACpower. Desiccantwheelbeginstorotate.
c. ReactivationmotorstarterRMScontactsclose,startingthereactivationblower.
d. COOLDOWNlightilluminates,indicatingthetimedheatercooldowncyclehasstarted.
e. TimerelayTR1startsthe5minuteheatercooldowncycle.Contactsarenormallyclosed,timed open(NCTO).Followingthedelay…
I. TR1relayenergizes,openingcontactsfortheCOOLDOWNlightandreactivationblowermotorstarter(RMS).Rotormotorterminals3470andX2de-energize.
Note:ThecooldowncyclecanbeinterruptediftheRUNpositionisselectedandnoalarmconditionsarepresent.
2. SelectingtheRUNposition(selectorswitch)…
a. ProvidespowertothetemperaturecontrolTC.
b. StartrelaySRenergizes,ifnoalarmconditionsarepresent(ARrelayde-energized)
I. TimerelayTR1andCOOLDOWNlightde-energize.Runindicatorilluminates.Reactivationblowermotorstarterisenergized.PressureswitchPS1isactivatedwhenreactivationairflowreachesminimumlevel.
II. TDR2startsa20seconddelayfollowedbyenergizingProcessmotorstart(PMS),hourmeter,andTDR440sectimer.IfpressureswitchPS1wasnotactivatedinpreviousstepduetolackofairflow,Alarmrelayisenergizedandunitisnotallowedtorun.
III. Heater“A”RelayHARenergizes,ifauxiliarycontactsofthereactivationmotoroverload(RMS)areclosedandthetemperaturecontroliscallingforheat.
IV. UponTDR4reaching40seconds,remainingheatcontactorsHBRandHCRareenergized
3. Iftemperatureinreactivationheaterplenumexceeds375°F,thetemperaturecontrolTCwillcloseitsauxiliarycontact,energizingthelatchingalarmrelayAR.
a. ALARMlampilluminates.
b. Alarmhornsounds.
c. Terminals3080andX2energize.Theseterminalscanbeutilizedforanexternalalarm(1ampmaximum).
d. TimerelayTR1startsthe5minuteheatercooldowncycle.Followingthedelay…
I. TR1relayenergizes,openingcontactsfortheCOOLDOWNlightandreactivationblowermotorstarter(RMS).Rotormotorterminals3470andX2de-energize.
ResetalarmbyturningtheselectorswitchtoSTANDBY.
Probablecausesforahightemperaturefaultarereducedairflow,dirtyfilter,incorrectreactivationblowerrotation,orblowerfailure.
Quest PowerDry 4800D Pro E Installation, Operation and Maintenance Instructions
17www.QuestProtect.com
questquest1-866-933-7486
4. Onafaultfromanoverloadrelay(OLR-PorOLR-R),thelatchingalarmrelay(AR)energizes.Theeffectislistedinlines3athrough3d. TurntheselectorswitchtoSTANDBY,allowingthecooldowncycletocompletebeforeturningOFFthemaindisconnect.FollowLockOut–TagOutproceduretode-energizethepowercordsupplyingthe4800.Resettheoverloadrelaylocatedinthecontrolcabinet.Closeandsecurecabinetdoor.EnergizeunitfollowingproperLockOut–TagOutprocedure. Probablecausesforafaultfromanoverloadrelayareinsufficientrestrictionofairflow(overloadingmotorbyallowingexcessiveairflow)orblower/motorfailure.
5. Onafaultfromtheinternalprocessdehumidistatthatpersistsfor20minutes,thelatchingalarmrelay(AR)energizes.Theeffectislistedinlines3athrough3d.TDR1providesa10minutedelayfortheremovalofresidualhumiditydesiccantduringstartup. ResetalarmbyturningtheselectorswitchtoSTANDBY. Probablecausesforafaultfromtheinternaldehumidistatareheaterfailureordesiccantfailure.
6. Onafaultfromastuckheatercontactor,theAlarmRelaywillenergizeandthereactivationblowerwillremainoncontinuously.TheRotorwillcontinuetoturn,buttheprocessblowerwillNOTcomeon.Shutoffpowerwiththemaindisconnectandreplacetheinoperablecontactortocleartheerror.
No dehumidistat is provided to monitor process inlet air condition (see over-dry warning section 3.5). An external control (dehumidistat, thermostat or other dry contact) can be wired in place of the jumper across terminals 1 and 3082. The external control must be designed to operate a 115 VAC circuit. Contact closure will start dehumidification. A control wired across terminals 1 and 3082 will be in series with the selector switch. Turn the selector switch to RUN to operate the dehumidifier from an external control.
9 Service Parts
Item Part No. Qty. Description
1 4027228 1 Blower,Reactivation,460V,5HP
2 4027229 1 Blower,Process,460V,7.5HP
3 4028630 1 Probe,Thermocouple,TypeJ,12”
4 4028633 3 HeatingElement,24KW
5 4020175 1 Dehumidistat
6 4028771 1 TemperatureControllerwith
ControlOutputBoard,RelaySPST
7 4028624 1 ControlBox
8 4030198 2 Fuse 2A
9 4030199 1 Fuse 4A
questquest
Quest PowerDry 4800D Pro E Installation, Operation and Maintenance Instructions
18www.QuestProtect.com
Warrantor:Therma-StorLLC4201 Lien RdMadison,WI53704Telephone:1-866-933-7486
Who Is Covered:Thiswarrantyextendsonlytotheoriginalend-useroftheQuestPowerDry4800DPro E desiccantdehumidifier,andmaynotbeassignedortransferred.
One Year Warranty:Therma-StorLLCwarrantsthat,forone(1)yeartheQuestPowerDry4800DPro E desiccantdehumidifierwilloperatefreefromanydefectsinmaterialsandworkmanship,orTherma-StorLLCwill,atitsoption,repairorreplacethedefectivepart(s),freeofanycharge.End-UserResponsibilities:WarrantyservicemustbeperformedbyaServicerauthorizedbyTherma-StorLLC.Iftheend-userisunabletolocateorobtainwarrantyservicefromanauthorizedServicer,theend-usershouldcallTherma-StorLLCattheabovenumberandaskfortheTherma-StorServiceDepartment.,whichwillthenarrangeforcoveredwarrantyservice.Warrantyservicewillbeperformedduringnormalworkinghours.
Theend-usermustpresentproofofpurchase(lease)uponreQuest,byuseofthewarrantycardorotherreasonableandreliablemeans.Theend-userisresponsiblefornormalcare.Thiswarrantydoesnotcoveranydefect,malfunction,etc.resultingfrommisuse,abuse,lackofnormalcare,corrosion,freezing,tampering,modification,unauthorizedorimproperrepairorinstallation,accident,actsofnatureoranyothercausebeyondTherma-StorLLC’reasonablecontrol.
Limitations and Exclusions:IfanyQuestPowerDry4800DProEDesiccantDehumidifierpartisrepairedorreplaced,thenewpartshallbewarrantedforonlytheremainderoftheoriginalwarrantyperiodapplicablethereto(butallwarrantyperiodswillbeextendedbytheperiodoftime,ifany,thattheQuestPowerDry4800DPro EDesiccantDehumidifierisoutofservicewhileawaitingcoveredwarrantyservice).
UPONTHEEXPIRATIONOFTHEWRITTENWARRANTYAPPLICABLETOTHEQuestPowerDry4800DPro EDESICCANTDEHUMIDIFIERORANYPARTTHEREOF,ALLOTHERWARRANTIESIMPLIEDBYLAW,INCLUDINGMERCHANTABILITYANDFITNESSFORAPARTICULARPURPOSE,SHALLALSOEXPIRE.ALLWARRANTIESMADEBYTHERMA-STORLLCARESETFORTHHEREIN,ANDNOCLAIMMAYBEMADEAGAINSTTHERMA-STORLLCBASEDONANYORALWARRANTY.INNOEVENTSHALLTHERMASTORLLC,INCONNECTIONWITHTHESALE,INSTALLATION,USE,REPAIRORREPLACEMENTOFANYQuestPowerDry4800DProEDESICCANTDEHUMIDIFIERORPARTTHEREOFBELIABLEUNDERANYLEGALTHEORYFORANYSPECIAL,INDIRECTORCONSEQUENTIALDAMAGESINCLUDINGWITHOUTLIMITATIONWATERDAMAGE(THEEND-USERSHOULDTAKEPRECAUTIONSAGAINSTSAME),LOSTPROFITS,DELAY,ORLOSSOFUSEORDAMAGETOANYREALORPERSONALPROPERTY.
Somestatesdonotallowlimitationsonhowlonganimpliedwarrantylasts,andsomedonotallowtheexclusionorlimitationofincidentalorconsequentialdamages,sooneorbothoftheselimitationmaynotapplytoyou.
Legal Rights:Thiswarrantygivesyouspecificlegalrights,andyoumayalsohaveotherrightswhichvaryfromstatetostate.
Quest PowerDry 4800D Pro E Desiccant Dehumidifier Limited Warranty