Qual Manual

download Qual Manual

of 18

Transcript of Qual Manual

  • 7/27/2019 Qual Manual

    1/18

    Quality ManualUC Davis Analytical Laboratory

    Effective Date:

    10/7/10

    Rev.:

    0004.02

    Page:

    1 of 18

    CopyrightTheRegentsoftheUniversityofCalifornia

    UC Davis Analytical LaboratoryQuality Manual

    Director:

    Dirk

    Holstege

    LaboratorySupervisor:TraciFrancis

    ManagementServicesOfficer:NikkiSchwab

    QualityAssuranceOfficer:KellyGardner

    DateofIssue: October7,2010

    UCDavisAnalyticalLaboratory

    224HoaglandHall

    OneShieldsAvenue

    Davis,CA

    95616

    5270

    Phone:5307520147

    Email:[email protected]

    WebSite:http://anlab.ucdavis.edu

    See Document History File for approval signatures.

  • 7/27/2019 Qual Manual

    2/18

    Quality ManualUC Davis Analytical Laboratory

    Effective Date:

    10/7/10

    Rev.:

    0004.02

    Page:

    2 of 18

    CopyrightTheRegentsoftheUniversityofCalifornia

    TableofContents

    Introductionand

    Laboratory

    Overview

    1. Scope

    2. References3. TermsandDefinitions4. ManagementProceduresandPolicies

    4.1 Organization

    4.2

    QualityManagement

    System

    4.3 DocumentControl

    4.4 ReviewofRequests

    4.5 SubcontractingofTests

    4.6 PurchasingServicesandSupplies

    4.7 ServicetotheClient

    4.8 Complaints

    4.9 ControlofNonconformingTestResults4.10 CorrectiveAction4.11 PreventiveAction

    4.12 ControlofRecords

    4.13 InternalAudits

    4.14 ManagementReviews

    4.15 Improvements

    5. TechnicalProceduresandPolicies5.1 General

    5.2 Personnel

    5.3 AccommodationandEnvironmentalConditions

    5.4 TestMethodsandMethodValidation

    5.5 Equipment

    5.6

    MeasurementTraceability

    5.7 Sampling

    5.8 SampleHandling

    5.9 AssuringtheQualityofTestResults

    5.10 ReportingTestResults

  • 7/27/2019 Qual Manual

    3/18

    Quality ManualUC Davis Analytical Laboratory

    Effective Date:

    10/7/10

    Rev.:

    0004.02

    Page:

    3 of 18

    CopyrightTheRegentsoftheUniversityofCalifornia

    Introductionand

    Overview

    Introduction

    Overview

    TheUCDavisAnalyticalLaboratorywasestablishedin1950atUCBerkeleyasan

    Extensionsoilstestinglaboratory.TheLabwasrelocatedtoHoaglandHallatUCDavisin

    1959. TheAnalyticalLaboratoryhassinceevolvedintoastateoftheartagricultural

    andenvironmentalanalyticallaboratory,testingsoil,plantmaterial,water,wastewater,

    andanimalfeed. TheAnalyticalLaboratoryisakeypartnerinthesuccessofUniversity

    ofCaliforniaresearch.

    LaboratoryPurpose

    ThepurposeoftheAnalyticalLaboratoryistoprovideUCresearcherswithinexpensive,

    highqualitytestingserviceinsupportofagriculturalandenvironmentalresearch

    activities.Researchqualitytestingallowsresearcherstoobtaindependableresults

    throughoutthelifetimeoftheirresearchprojects,whichareoftenmultiyearin

    duration.Lowcostenablesresearcherstomeettheexpenseofthelargenumberof

    testsnecessaryinagriculturalandenvironmentalresearch,andtocompetesuccessfully

    forprojectfunding. Thelaboratoryprovidestestingsupportfordiagnosticfield

    investigationsby

    CE

    Advisors.

    LaboratoryOrganization

    ThelaboratoryisaselffundedunitwithintheUCDavisCollegeofAgriculturaland

    EnvironmentalSciences.ThelaboratoryisheadedbyaDirector,andstaffedwitha

    ManagementServicesOfficer,aProgrammer,aQualityAssuranceOfficer,aLaboratory

    Supervisor,oneofficeassistant,oneReceivingAreamanager,sixstaffchemistsand

    severalparttimestudentassistants.Theuseofstateoftheartanalyticalequipment,

    methodsandfacilitiesiscriticaltothesuccessofthelaboratory.Thelaboratoryoccupies

    over5000squarefeetinHoaglandHallandtheHoaglandAnnex.

    MissionQualityPolicyStatement

    Toprovidehighqualityandtimelyanalysesofsoil,plant,water,feed,and

    othersamplesandtocontinuouslymeettherequirementsand

    expectationsofourclients.

  • 7/27/2019 Qual Manual

    4/18

    Quality ManualUC Davis Analytical Laboratory

    Effective Date:

    10/7/10

    Rev.:

    0004.02

    Page:

    4 of 18

    CopyrightTheRegentsoftheUniversityofCalifornia

    CoreValues

    AttheUCDavisAnalyticalLaboratoryweholdthefollowingprinciplesandvaluestobe

    themostimportant,andweconsiderthesevaluesinmakingdecisions:

    honesty safetyofouremployeesandcommunity goodscience fairness quality

    EthicsPolicy

    Ethicsisasetofmoralprinciples,acodeforrightandwrong,orbehaviorwhich

    conformstoacceptedprofessionalpractices.

    Allemployeesatalltimesshallconductthemselvesinanhonestandethicalmanner.Examplesofunethicalbehaviorinclude,butarenotlimitedtothefollowing:

    Impropermanipulationofdataorsoftware Improperhandlingofdataerrors,noncompliantdata,orQCoutliers Lackofreportingunethicalbehaviorbyothers Artificiallyfabricatingresults Misrepresentingdatasuchaspeakintegration,calibration,tuning,orsystemsuitability

    Improperclocksettingtomeetholdingtimes Intentionaldeletionofnoncompliantdata

    Anemployeemustreportanysuspectedunethicalbehaviororfraudulentactivitiestoa

    supervisor.Anemployeehastherighttoremainanonymous.

    Confidentiality

    Clientinformationisconfidentialandwillnotbediscussedwithanyone,eventhose

    affiliatedwiththeclientnotdesignatedasacontact,withoutpermissionfromtheclient.

    Confidentialinformationincludestestresults,originofsamples,businessrelationship

    withtheclient,anyproceduresandtestingthattheyconductorinvestigate,and

    informationabouttheirresearch.

    InstrumentServices

    Thelaboratorymaintainsstateoftheartanalyticalequipment.Majorpiecesof

    equipmentinclude:

    ThermoIrisinductivelycoupledplasmaemissionspectrometer(ICPAES) ThermoiCAP6500inductivelycoupledplasmaemissionspectrometers(ICPAES) PerkinElmer/SciexAPI2000HPLC/MS/MS

  • 7/27/2019 Qual Manual

    5/18

    Quality ManualUC Davis Analytical Laboratory

    Effective Date:

    10/7/10

    Rev.:

    0004.02

    Page:

    5 of 18

    CopyrightTheRegentsoftheUniversityofCalifornia

    PerkinElmerAAnalyst800flame/graphitefurnaceatomicabsorptionspectrometer

    PerkinElmerAAnayst300flameatomicabsorptionspectrometer(AA) CEMmicrowavesampledigestionsystem LachatFlowInjectionAnalyzers(FIA) TimberlineFlowInjectionAmmoniumAnalyzer LECOFP528NitrogenAnalyzer LECOTruSpeccarbon/nitrogenanalyzer ThermoFinneganSeries1112carbon/nitrogenanalyzer DionexICS2000IonChromatograph Varian3800GasChromatographwithSaturn2000GC/MS SkalarFormacsHTTOC/TNAnalyzer

    TestingServices

    information

    details

    available

    on

    the

    laboratory

    website

    Soilstestingservicesincludesalinity,alkalinityandtoxicitytests,soilfertilitytests,soilcharacteristicsandphysicalproperties,andmineralanalysis.

    Plantandfeedtestingincludescarbonandnitrogentesting,nutrientandmineralanalysis,fibertestingandcarbohydratetesting.

    Waterandwastewatertestingincludestestsforwaterquality,includingsediment,nutrients,salinity,alkalinityandtoxicity,andsolubleandacid

    digestibleelements.

    QualityControlandQualityAssurance

    QualityControl(QC)referstostepstakentoensureandmonitorprecisionandaccuracy

    oftestresults. QualityControlpracticesincludetheanalysisofqualitycontrolsamples

    witheachsetofsamples.Theseincludecalibrationstandards,certifiedreference

    materials,spikedsamples,duplicatesampleanalysis,andblanks. AdditionalQC

    measuresincludetheanalysisofblindduplicatesamplesandparticipationinvarious

    proficiencytestingprograms.

    QualityAssurance(QA)referstoacompletelyseparateandindependentmonitoringof

    laboratorystudies

    and

    Quality

    Control

    activities.

    Quality

    Assurance

    activities

    include

    the

    internalauditprogram,reviewofdatapackages,evaluationofnonconformances,and

    anannualManagementReviewofqualitydata. ThelaboratoryfollowsISO17025and

    ISO9001internationalstandardsastheyareapplicableandsignificantforthetesting

    requestedbyclient.

  • 7/27/2019 Qual Manual

    6/18

    Quality ManualUC Davis Analytical Laboratory

    Effective Date:

    10/7/10

    Rev.:

    0004.02

    Page:

    6 of 18

    CopyrightTheRegentsoftheUniversityofCalifornia

    Section1. ScopeoftheQualityManual

    TheQuality

    Manual

    contains

    the

    policies

    and

    procedures

    used

    for

    the

    quality

    managementsystemoftheUCDavisAnalyticalLaboratory:

    togeneratetestresultsthataretechnicallysoundandhavetherequiredaccuracyandprecision

    tomeetclientrequirements tomeetregulatoryrequirements tomaintainclientsatisfaction

    ThepoliciesandproceduresoftheQualityManualareapplicabletoalltesting

    performedinthelaboratory,unlesssupersededbyaprojectorclientspecificquality

    plan.

    TheQualityManualisdividedintofivesections:

    Section1,ScopeoftheQualityManual,describesthescopeoftheQualityManual.

    Section2,References,listsnormativedocumentsreferencedbythismanual. Section3,TermsandDefinitions,definestermsusedinthismanual. Section4,ManagementPoliciesandProcedures, specifieshowsoundmanagementisdemonstratedandclientsatisfactionismaintained.

    Section5TechnicalProceduresandPoliciesspecifieshowtechnicalcompetence

    in

    the

    laboratory

    is

    demonstrated.

  • 7/27/2019 Qual Manual

    7/18

    Quality ManualUC Davis Analytical Laboratory

    Effective Date:

    10/7/10

    Rev.:

    0004.02

    Page:

    7 of 18

    CopyrightTheRegentsoftheUniversityofCalifornia

    Section2. References

    Thelaboratory

    complies

    with

    the

    requirements

    of

    this

    Quality

    Manual.

    Totheextentthatisreasonableandfeasible,ISO17025requirementsareaddressedin

    laboratorysystemsandprocedures. TheUCDavisAnalyticalLaboratoryisnotfully

    compliantwithISO17025requirementsorISO17025certified. TheQualityManualis

    intentionallynumericallyalignedwithISO17025requirementstoprovideastandard

    format.

    Thefollowingnormativedocumentscontainprovisionswhich,throughreferenceinthis

    text,constituteprovisionsofthisQualityManual.

    CertificationofEnvironmentalLaboratories.CaliforniaCodeofRegulations,Title22,Division4,Chapter19.

    ISO17025:2005,GeneralRequirementsfortheCompetenceofTestingandCalibrationLaboratories.

    ISO9001:2000,QualityManagementSystemsFundamentalsandVocabulary. ISO/IEC17000,ConformityAssessmentVocabularyandGeneralPrinciples. NationalInstituteofStandardsandTechnology(NIST),StandardReferenceMaterialsProgram,Gaithersburg,MD20899.

  • 7/27/2019 Qual Manual

    8/18

    Quality ManualUC Davis Analytical Laboratory

    Effective Date:

    10/7/10

    Rev.:

    0004.02

    Page:

    8 of 18

    CopyrightTheRegentsoftheUniversityofCalifornia

    Section3. TermsandDefinitionsAccreditationformalrecognitionofalaboratorybyanindependentsciencebased

    organizationthat

    the

    laboratory

    is

    competent

    to

    perform

    specific

    tests

    (CASCO).

    Document ahardcopyorelectronicfilecontaininginformation,data,orprocedures

    thataregenerallyinuse. AcurrentSOPisanexampleofadocument. Anobsolete

    versionofaSOPthathasbeenarchivedisanexampleofarecord.

    Frozen temperatureof0

    Cto5

    C(perEPAManualfortheCertificationof

    LaboratoriesAnalyzingDrinkingWater)

    Nonstandardtesting alaboratorytermthatdescribesanyanalysisthatisnotlistedon

    theAnalyticalLaboratorywebsiteasastandardanalysisthatisofferedbythe

    laboratory.

    Record ahardcopyorelectronicfilecontainingdata,results,observations,orother

    informationrelevanttolaboratorytestingandoperations. Ingeneral,arecordhasbeen

    completedandstored,andisnolongerindailyuse.Examplesincluderesultsreports,

    datapackages,obsoleteversionsofSOPs,andnonconformancereports.

    Refrigerated temperaturerangeof6

    C+/ 2

    C(perEPAManualfortheCertification

    ofLaboratoriesAnalyzingDrinkingWater)

    RoomTemperature

    ambient

    temperature

    20

    30

    C(per

    EPA

    Manual

    for

    the

    CertificationofLaboratoriesAnalyzingDrinkingWater)

    StandardMethod alaboratorytermthatdescribesanylaboratorymethodforwhich

    aStandardOperatingProcedurehasbeenestablished.

    StandardTesting AlaboratorytermthatdescribesanyanalysisthatislistedontheUC

    DavisAnalyticalLaboratorywebsiteasastandardanalysisofferedbythelaboratory.

    WorkRequestaformthatiscompletedbytheclientwithsampleinformationandthe

    analysis

    requested.

    A

    completed

    Work

    Request

    Form

    must

    be

    submitted

    with

    the

    samples.

    WorkRequestnumberauniqueidentificationnumberassignedtoasetofsamples.

    TheformatfortheWorkRequestnumberisthelasttwodigitsofthefiscalyearcode

    letterforthesampletype athreedigitsequentialnumber. Forexample10F012would

    bethetwelfthsetoffeedsamplessubmittedinfiscalyear1011.

  • 7/27/2019 Qual Manual

    9/18

    Quality ManualUC Davis Analytical Laboratory

    Effective Date:

    10/7/10

    Rev.:

    0004.02

    Page:

    9 of 18

    CopyrightTheRegentsoftheUniversityofCalifornia

    Section4.ManagementPoliciesandProcedures

    Thelaboratory

    is

    divided

    into

    five

    groups

    in

    the

    following

    manner:

    Group Components

    Laboratory AnalyticalTesting

    Administrative AdministrativeManagementandSupport

    InformationTechnology ITSupport

    LabSupport SampleReceivingandPreparation

    QualityAssurance QualityAssurance

    TheAnalyticalLaboratoryManagementSystemhasthefollowingcomponents:

    4.1OrganizationalStructure. Thelaboratoryhasanorganizationalstructurethat:

    givesmanagerialandtechnicalpersonneltheauthorityandresourcesneededtocarryouttheirduties,identifytheoccurrenceofdeparturesfromthequality

    systemandtoinitiateactionstopreventsuchdepartures(nonconformances)

    haspoliciesandprocedurestoensuretheprotectionofclients'confidentialinformationandproprietaryrights

    haspoliciesandprocedurestoavoidinvolvementinanyactivitiesthatwoulddiminishconfidenceinthelaboratoryscompetence,impartiality,judgmentor

    operationalintegrity

    providesadequatesupervisionoftestingstaff,includingtrainees,bypersonsfamiliar

    with

    methods

    and

    procedures

    hastechnicalmanagementwithoverallresponsibilityforthetechnicaloperationsandtheprovisionoftheresourcesneededtoensuretherequired

    qualityoflaboratoryoperations

    hasaqualityofficerwhohasdefinedresponsibilityandauthorityforensuringthatthequalitysystemisimplementedandfollowedatalltimes

    4.2QualityManagementSystem.ThelaboratoryhasaQualityManagementSystem

    thatsupportsthelaboratorymanagement'scommitmenttogoodprofessionalpractice

    andtothequalityofitstesting.TheeffectivenessoftheQualityManagementSystemis

    assessedin

    several

    ways:

    byaprogramofplannedinternalaudits,coveringallaspectsoftheoperationofthequalitymanagementsystem

    byregularmanagementreviewsofthesuitabilityandeffectivenessofthequalitymanagementsystem

  • 7/27/2019 Qual Manual

    10/18

    Quality ManualUC Davis Analytical Laboratory

    Effective Date:

    10/7/10

    Rev.:

    0004.02

    Page:

    10 of 18

    CopyrightTheRegentsoftheUniversityofCalifornia

    byanalysisofpotentialandactualproblemsasdocumentedinthenonconformancereportsystem,byclientcomplaints,andotherrelevant

    assessments

    4.3DocumentControl.TheLaboratorycontrolsalldocumentsthatformpartofits

    qualitysystem,suchastheQualityManual,testmethods(methodSOPs),other

    laboratoryprocedures(SOPs),andinstrumentmanuals. Regulations,standards,and

    publishedtestmethodsarereferenced,whenused.

    4.4ReviewofTestRequestsandContracts.Thelaboratoryhasproceduresforthe

    reviewofrequestsforworktoensurethattherequirements,includingthemethodsto

    beused,areadequatelydefined,thatthelaboratoryhasthecapabilityandresourcesto

    meetclientrequirements,andthattheappropriatetestmethodisselectedandis

    capableof

    meeting

    clients

    requirements.

    ThelaboratoryprovideseachclientwithapreprintedWorkRequestFormtocapturetheclientsrequestfortestingandassociatedrequirements. TheWork

    RequestFormliststheanalysesavailableforeachsampletype.TheWork

    RequestFormmustbecompleted,signedbytheclient,andsubmittedwiththe

    samplestobetested.

    Ifreviewoftheworkrequesthighlightsanyambiguitiesoruncertainties,theclientiscontactedandtheproblemresolved. Aconfirmationemailwithafee

    estimateandthecompletedWorkRequestFormasascannedfileissenttothe

    client.

    Theclienthasanopportunitytonotifythelaboratoryifanychangesarerequiredorrequested. TestingiscommencedaccordingtothecompletedWorkRequest

    Formunlessthelaboratoryisotherwisenotifiedbytheclient.

    4.5SubcontractingofTests.Thelaboratoryhasaprocedureforsubcontractingtests

    suchthatthisworkisplacedwithacompetentsubcontractor,thattheclientisnotified

    ofthearrangement,andthatthelaboratorysresponsibilityforthetestingisdefinedto

    theclient.

    4.6PurchasingServicesandSupplies. Thelaboratoryhasproceduresfortheselection,

    purchasing,receipt,andstorageofsuppliesthataffectthequalityofthetests,including

    reagentsandlaboratoryconsumables.

  • 7/27/2019 Qual Manual

    11/18

    Quality ManualUC Davis Analytical Laboratory

    Effective Date:

    10/7/10

    Rev.:

    0004.02

    Page:

    11 of 18

    CopyrightTheRegentsoftheUniversityofCalifornia

    4.7Servicetotheclient.TheLaboratorycooperateswithclientstoclarifytheclient's

    requestandtomonitorthelaboratory'sperformanceinrelationtotheworkperformed.

    Servicetotheclientincludes:

    affordingtheclientreasonableaccesstorelevantareasofthelaboratoryforthewitnessingofworkperformedfortheclient. Suchaccessmustnotconflictwith

    rulesofconfidentialityofworkforotherclientsorwithsafety.

    maintainingopencommunication.Contactwiththeclient,especiallyinlargeassignments,ismaintainedthroughoutthework.Thelaboratoryinformsthe

    clientofanydelaysormajordeviationsintheperformanceofthetests.

    preparing,packaging,anddispatchingofsamplesneededbytheclientforverificationpurposes.

    thelaboratoryseeksfeedbackfromclients.4.8

    Complaints.

    The

    Laboratory

    has

    apolicy

    and

    procedure

    for

    the

    resolution

    of

    complaintsreceivedfromclients.Recordsofcomplaintsaredocumentedonthenon

    conformancereportformandincludethefollowinginformation:

    detailsofthecomplaint investigation correctiveandpreventiveactions followupverification

    4.9ControlofNonConformingTesting. Thelaboratoryhasproceduresthatare

    implementedwhenanyaspectofitstestingdoesnotconformtorelevantproceduresor

    therequirements

    agreed

    upon

    with

    client.

    These

    include

    defining

    the

    responsibilities

    for

    themanagementofnonconformingwork,actionstakenwhennonconformingworkis

    identified,anevaluationofthesignificanceofthenonconformingwork,remedial

    actionstaken,andclientnotification.

    Situationsthatrequireanonconformancereportinclude:

    failureorsuspectedfailuretocomplywithtestmethod,orotherlaboratorySOPssuchthattheintegrityofthetestresultsmaybejeopardized

    calibrationresultsormaintenanceactivitiesthatindicateanequipmentmalfunctionhasoccurredandmayhaveimpactedtestresults

    testresultsdonotmeettheregulatoryorclientdefinedacceptancecriteria resultsofqualitycontrolsamples(duplicates,SRMs,blanks,spikes)thatareoutsideofestablishedranges

    proficiencytestingprogramresultsthatareoutsideofexpectedranges clientcomplaints

  • 7/27/2019 Qual Manual

    12/18

    Quality ManualUC Davis Analytical Laboratory

    Effective Date:

    10/7/10

    Rev.:

    0004.02

    Page:

    12 of 18

    CopyrightTheRegentsoftheUniversityofCalifornia

    4.10CorrectiveAction.Thelaboratoryhasapolicyandprocedureforimplementing

    correctiveactionwhennonconformingworkordeparturesfromthepoliciesand

    proceduresinthequalitysystemortechnicaloperationshavebeenidentified.

    4.11PreventiveAction.Neededimprovementsandpotentialsourcesofnon

    conformancesareidentified.Ifpreventiveactionisrequired,actionplansare

    developed,implementedandmonitoredtoreducethelikelihoodoftheoccurrenceof

    suchnonconformancesandtotakeadvantageoftheopportunitiesforimprovement.

    4.12ControlofRecords.Thelaboratoryhasproceduresforidentification,collection,

    indexing,access,filing,storage,maintenanceanddisposalofqualityandtechnical

    records.

    Allrecordsarelegibleandareretainedinsuchawaythattheyarereadilyretrievable.

    The

    retention

    time

    for

    hard

    copy

    records

    is

    one

    year.

    Electronic

    recordsareretainedfiveyears.

    Allrecords,includingtestreports,aresafelystoredinlockedareas. Proceduresareinplacefortheidentification,access,maintenance,andstorageofelectronicrecordstopreventunauthorizedaccessormodificationofthese

    records.

    4.13InternalAudits. Thelaboratoryconductsinternalauditsofitsactivitiestomonitor

    compliancewiththerequirementsofthequalitysystem.Theinternalauditprogram

    involvesperiodicauditsofallelementsoftheQualityManual. Theseauditsinclude

    systemaudits,suchasTraining,andtheNonConformanceSystem,andalsodata

    packageaudits.

    4.14Managementreviews.Thelaboratory'smanagementteamperiodicallyconductsa

    reviewofthelaboratory'squalitysystemandtestingactivitiesforcontinuingsuitability

    andeffectiveness,andtointroducenecessarychangesorimprovements.

    4.15Improvements.Thelaboratorycontinuallyimprovestheeffectivenessofits

    managementsystemthroughtheuseofthequalitypolicy,qualityobjectives,audit

    results,analysisofdata,correctiveactions,preventiveactions,andmanagementreview.

  • 7/27/2019 Qual Manual

    13/18

    Quality ManualUC Davis Analytical Laboratory

    Effective Date:

    10/7/10

    Rev.:

    0004.02

    Page:

    13 of 18

    CopyrightTheRegentsoftheUniversityofCalifornia

    Section5. TechnicalProceduresandPolicies

    5.1General

    Information.

    The

    UC

    Davis

    Analytical

    Laboratory

    has

    technical

    procedures

    andpoliciesinplacetodeterminethecorrectnessandreliabilityoftestresults.The

    correctnessandreliabilityoftestresultsareimpactedbymanyfactors:

    analysttechnique/staffperformance facilityandenvironmentalconditions testmethodsandmethodvalidation equipment measurementtraceability(referencematerialsandcalibration) sampling samplehandling

    ThesefactorsareaddressedbythetechnicalproceduresandpoliciesoftheAnalytical

    Laboratory.Theextenttowhichthesefactorscontributetototalmeasurement

    uncertaintydiffersbetweentypesoftests.Thesefactorsaretakenintoconsideration

    andevaluatedduringtesting,thetrainingandqualificationofpersonnel,the

    developmentandvalidationoftestmethodsandprocedures,andintheselectionand

    calibrationofequipment.

    5.2Personnel.Managementensuresthecompetencyofallpersonnel,includingthose

    performingtestsandsupportfunctions,thoseevaluatingresults,andthosesigningtest

    reports.Training

    is

    documented

    to

    ensure

    all

    procedures

    are

    performed

    by

    trained

    personnel.Managementauthorizesspecificpersonneltooperateparticulartypesof

    equipment,toperformparticulartypesoftesting,andtoissuetestreports.

    5.3AccommodationandEnvironmentalConditions. Thelaboratoryisequippedto

    provideasuitableenvironmentforcorrectperformanceofthetests.

    Environmentalconditionsaremonitored,controlled,andrecordedasrequiredbythetestmethodsandproceduresorwheretheymayinfluencethequalityof

    testresults. Testingisstoppedwhentheenvironmentalconditionsjeopardize

    theresults

    of

    the

    tests.

    Effectiveseparationbetweenneighboringareasismadewhentheactivitiesareincompatible.Measuresaretakentopreventcrosscontamination.

  • 7/27/2019 Qual Manual

    14/18

    Quality ManualUC Davis Analytical Laboratory

    Effective Date:

    10/7/10

    Rev.:

    0004.02

    Page:

    14 of 18

    CopyrightTheRegentsoftheUniversityofCalifornia

    5.4TestMethodsandMethodValidation.

    RoutinemethodsaredocumentedintheAnalyticalLaboratoryStandardOperating

    Procedures(SOP)manual.SOPsarereviewedannuallyandrevisedasneeded;revision

    datesand

    summary

    of

    changes

    are

    documented

    in

    each

    SOP.

    The

    references

    used

    for

    eachmethodaredocumentedintheSOPs.

    Thelaboratoryusesappropriatemethodsandproceduresforalltestswithinitsscope.Theseincludehandling,storageandpreparationofsamplestobetested.

    Thelaboratoryhasinstructionsontheuseandoperationofallrelevantequipment,andonthehandlingandpreparationofsamples,wheretheabsence

    ofsuchinstructionscouldjeopardizetheresultsoftests.

    Thelaboratoryusestestmethodswhichmeettheneedsoftheclientandwhichareappropriateforthetestsitundertakes.

    MethodsthataredevelopedormodifiedinhousearedetailedinmethodSOPsandarevalidatedtothedegreeappropriatefortheirintendeduse.

    Calculationsanddatatransfersaresubjecttoappropriatechecksinasystematicmanner.Proceduresareestablishedandimplementedforprotectingthedata.

    Thelaboratoryestimatestheuncertaintyoftestmethodsbyidentifyingthesignificantcomponentsofmeasurementuncertainty,makingareasonable

    estimation,andensuringthattheformatofreportingoftheresultsdoesnotgive

    anexaggeratedimpressionoftheuncertainty.

    5.5Equipment. Thelaboratoryisfurnishedwithallitemsoftestequipmentrequired

    for

    the

    correct

    performance

    of

    the

    tests.

    The

    equipment

    is

    capable

    of

    achieving

    the

    accuracyrequired,andiscalibratedbeforeuse.

    InstrumentCalibrationandStandardOperatingConditions.Specifications,settingsandinstructionsforcalibratingaredescribedinspecificmethodSOPs.

    InstrumentMaintenanceLogs.Alogismaintainedforallmajorequipment.Operatorsincludeacontinuingrecordofproblems,repairs,andmaintenance

    actionsineachinstrumentlog.

    InstrumentPerformanceChecks.AdescriptionofhowtoevaluateinstrumentperformancebyperformancechecksiscontainedintheindividualAnalytical

    MethodSOPs.Ifananalysisfailstomeetperformancecriteria,thecauseis

    investigated.

    CalibrationofSupportEquipment.BalancesarecalibratedagainstNISTtraceableweights.PipettesandPipettorsarecalibratedandcheckedbyweight.

    Refrigeratorandfreezertemperaturesaremonitoredandrecordedonthelog

    attachedtoeachunit.Allexhaustorfumehoodsarecheckedannuallyfor

    averagefacevelocitywiththesashopentotheindicatedmark.

  • 7/27/2019 Qual Manual

    15/18

    Quality ManualUC Davis Analytical Laboratory

    Effective Date:

    10/7/10

    Rev.:

    0004.02

    Page:

    15 of 18

    CopyrightTheRegentsoftheUniversityofCalifornia

    5.6MeasurementTraceability.Thetraceabilityofmeasurementsisensuredthrough

    equipmentcalibrationandmaintenance,andtheuseofanalyticalstandardswith

    appropriatetraceability.

    Theprogramforcalibrationofequipmentisdesignedandoperatedtoensure

    measurementsaretraceabletotheInternationalSystemofUnits(SI)totheextent

    necessaryandappropriaterelativetothestateduncertaintyofthetestormeasurement.

    Thisistypicallyaccomplishedviatheuseofstandardsthatarecertifiedtobetraceableto

    NISTorothernationalstandards.

    WheretraceabilitytoSIunitsofmeasurementisnotpossibleand/ornotrelevant,other

    meansforprovidingconfidenceintheresultsareappliedsuchas:

    theuseofcertifiedreferencematerialsprovidedbyasuppliersuitabletogiveareliablephysical

    or

    chemical

    characterization

    of

    the

    material.

    mutualconsentstandardsormethodswhichareclearlyspecifiedandagreeduponbyallpartiesconcerned.

    participationinasuitableprogramofinterlaboratorycomparisonsorproficiencytesting.

    inhousereferencematerialverifiedbyinterlaboratorycomparisonsorproficiencytesting.

    5.7Sampling.TheUCDavisAnalyticalLaboratorydoesnotperformsamplecollection.

    Samplingrecommendationsareprovidedonthelaboratorywebsite.

    5.8SampleHandling. Proceduresareestablishedforthereceipt,handling,protection,

    storage,retentionanddisposalofsamples,includingallprovisionsnecessarytoprotectthe

    integrityofthesampleandtheinterestsofthelaboratoryandtheclient.

    SampleSubmission.SamplesaresubmittedtothelaboratorywithaWorkRequestForm.TheWorkRequestFormdocumentsthesampling,holding,andshipmentof

    samplesfromtheclienttothelaboratory.TheWorkRequestFormalsoservesasthe

    client'srequest/ordertoperformspecifictests.

    SampleLogIn.SamplesarereceivedintheSampleReceivingarea(110HoaglandAnnex)

    where

    the

    Receiving

    Manager

    or

    trained

    personnel

    are

    responsible

    for

    logginginthesamplesinaccordancewiththeSampleReceivingSOP. Atlogin,each

    clientusesacustomizedworkrequestformthathasthefollowinginformation:

    o ClientID(assignedbytheLab)o ClientName/phonenumber/Email/AlternateContactinformationo Billinginformationo Numberofsamples

  • 7/27/2019 Qual Manual

    16/18

    Quality ManualUC Davis Analytical Laboratory

    Effective Date:

    10/7/10

    Rev.:

    0004.02

    Page:

    16 of 18

    CopyrightTheRegentsoftheUniversityofCalifornia

    o Sampleinformationanddescriptionso Desiredsampledispositiononcompletionofthetestingo Requiredsamplepreparationo Testsrequestedo SignatureoftheClientorresponsiblepartyo Deliverymethodornameofpersondeliveringsamples

    AsequentialnumberisassignedtoeachWorkRequest.

    IdentificationofSamples.Samplesaresystematicallyidentifiedusinguniquetrackingnumbers(consistingoftheWorkRequestnumberfollowedbyauniquesequential

    number)aftertheyarriveatthelaboratory. Thisidentificationisretainedthroughout

    thelifeoftheiteminthelaboratory.Thesystemisdesignedandoperatedsoasto

    ensurethatitemscannotbeconfusedphysically,orwhenreferredtoinrecordsor

    otherdocuments.

    ChainofCustody.Thelocationofthesamplesaretrackedinternallyusingabarcodingsystem.Internaltrackingofsamplelocationisfollowedforallsamples.

    ExternalChainofCustody(CoC)proceduresarefollowedforsamplesreceivedwith

    CoCforms.TheCoCrecordisusedtodocumentthechangeinpossessionfrom

    samplingtodeliverytoreceiptbythelaboratory.Eachsamplemustbeclearly

    identifiable.Theconditionofthesampleisnoteduponreceipt.Signaturesofparties

    relinquishingcustodyaswellasthedatearedocumentedontheWorkRequest

    FormandanyexternalCoCform.

    ClientNotificationofSampleReceipt.The LaboratoryInformationManagementSystem(LIMS)organizessampledatainsuchamannerthatloginentriescanbe

    verified,sampleprogresscanbetracked,analyticaldatacanbeappendedtothe

    record,andfinalreportscanbecreated.Whenloginhasbeenreviewed,asample

    confirmationemailissenttotheclient.

    SampleStoragePriortoAnalysis.Samplesareloggedinwithinoneworkingdayofreceipt.Samplesarestoredappropriatelyafterreceipt.Samplesrequiring

    immediateprocessingsuchasdryingareprocessedimmediatelyfollowinglogin.

    SamplesthathavebeenloggedinandprocessedarestoredbyWorkRequest

    Number.Separate

    storage

    is

    maintained

    to

    segregate

    sample

    types

    where

    cross

    contaminationisapossibility.

    ShippingandReceiving.TheLabisopenforsamplereceiptfrom8:00a.m.to5:00p.m.,MondaythroughFriday,excludingUniversityofCaliforniaholidays.Adropbox

    isavailableforafterhourssampledropoff.Latenight,weekend,orholidaysample

  • 7/27/2019 Qual Manual

    17/18

    Quality ManualUC Davis Analytical Laboratory

    Effective Date:

    10/7/10

    Rev.:

    0004.02

    Page:

    17 of 18

    CopyrightTheRegentsoftheUniversityofCalifornia

    receiptcanbearranged.Foremployeesafety,anyknownsamplehazardsmustbe

    explainedinthepaperworksentwithsamples.

    SampleDisposition.SampleDisposition: ClientscanselectsampledispositionpreferenceontheWorkRequestForm.Samplesarediscardedorreturnedtothe

    client30daysafterthefinalreportisissued.

    5.9QualityControl/QualityAssurance.Qualitycontrolproceduresareusedforalltest

    methodsperformedinthelaboratorytomonitorthevalidityoftestresults.The

    resultingdataareevaluatedbytheanalystandsupervisor. Resultsarealsotrackedand

    trendedatleastannuallyorasneeded. Theseproceduresincludethefollowing:

    regularuseofreferencestandards,whereavailable,forcalibration analysisofatleastonereferencematerialsamplewitheachbatch participationininterlaboratorycomparisonsandproficiencytestingprograms analysisofblanksandspikedsamplesasappropriate replicatetestsofthesamesampleduringanalysis(duplicates) retestingofretainedsamples(blindduplicateprogram) correlationofresultsfordifferentcharacteristics

    Thequalitycontrolprogramconsistsofbothinternalandexternalchecksonprecision

    andaccuracyofanalyticalresults.Theresponsibilityformaintainingtheprogramrests

    withtheQualityAssuranceOfficer.Employeesaretrainedinqualitycontrolprocedures

    andconcepts.

    InternalQualityControl.ThefollowingQCsamplesareanalyzedwithclientsamples:

    Blank.Areagentblankisanalyzedwitheverysetofsamplesthatisextractedordigested. Thisreagentblankincludesanyandallreagentsthatareusedinthe

    analyticalprocessandiscarriedthroughtheentireprocess,includingextraction

    andfilteringordigestion.

    Duplicates.Atleasttenpercentofsamplesareanalyzedinduplicatetoyielddataontheprecisionoftheanalysis.Duplicateresultsareincludedinthereport.

    ReferenceMaterials.Atleastonereferencematerialisanalyzedwitheachsetofsamples. Thevaluesforthereferencematerialsareincludedinthefinalreport.

    Samplesrun

    with

    areference

    material

    that

    falls

    outside

    the

    control

    limit

    are

    reanalyzed,includingdigestionorextractionifnecessary.Theuseofdataoutside

    ofwarninglimitsisatthediscretionoftheLabSupervisororreviewinganalyst.

    SpikeSamples.Samplefortificationsorspikesareusedtoverifyaccuracyoftestsrequiringextensivesamplemanipulation(suchasaciddigestion)orfornon

    standardsampletypes.

  • 7/27/2019 Qual Manual

    18/18

    Quality ManualUC Davis Analytical Laboratory

    Effective Date:

    10/7/10

    Rev.:

    0004.02

    Page:

    18 of 18

    Copyright The Regents of the University of California

    BlindDuplicates.Periodictestingisperformedonasubsetofsamplesthathavebeen

    previouslyanalyzed.Thesesamplesarereloggedintothelaboratoryasnewsamples,

    andtheresultscomparedtotheoriginalresults.

    ExternalQualityControlProgramsTheUCDavisAnalyticalLaboratoryparticipatesinanumberofsampleexchangeand

    certificationprograms.

    InternationalPlantAnalyticalExchange(IPE)planttissueanalyses ManureAnalysisProgram(MAP) manureanalyses NorthAmericanProficiencyTestingProgram(NAPT) planttissueanalyses NorthAmericanProficiencyTestingProgram(NAPT) soilanalyses NorthAmericanProficiencyTestingProgram(NAPT)wateranalyses NationalForageTestingAssociation(NFTA) feedanalyses AgriculturalLaboratoryProficiencyprogram(ALP) planttissueanalyses

    5.10ReportingTestResults.Theresultsofeachtestarereportedaccurately,clearly,

    unambiguouslyandobjectively,andinaccordancewithanyspecificinstructionsinthe

    testmethods.

    Testreportsincludethefollowinginformation,asappropriate:

    clientprovidedinformation:commodity,sampletype,datesampled,grower/location/project

    methodSOPused analysisdate unitsofmeasurement sampleidentificationnumber sampledescription(ifsubmittedbyclient) testresults asummaryofqualitycontrolresults

    o methoddetectionlimit(MDL)whichistypicallyaquantitationlimitfortheanalysis

    o referencematerialresultsandcriteriao resultsofduplicateanalyses

    notes

    and

    comments

    related

    to

    test

    results

    signatureandtitleofperson(s)reviewingandapprovingreport(maybeelectronic)

    Datareportedtotheclientcontainstheappropriatesignificantdigitsforeachtest

    method.TestresultsthatarebelowthelaboratoryMDLarenotedassuch. All

    appropriatewarningsandnotesareincludedonthefinalreport.