Pvma32xx series-raid

19
PVMA32xx-series-RAID Marc van Schijndel Country Manager ttec

description

Presentation on the New Provigo PVMA32xx series FC RAID systems

Transcript of Pvma32xx series-raid

Page 1: Pvma32xx series-raid

PVMA32xx-series-RAIDMarc van Schijndel

Country Manager ttec

Page 2: Pvma32xx series-raid

2

Product Strategy

Product strategy …… a refresh of the Entry Level 2000 Series …

… the 3000 Series• Laying the groundwork for the next generation

Higher processor performance and I/O speeds Support for enhanced and new DMS functionality Latest generation components for low cost and long lifecycles

• New Controller Design PCI Express Architecture Intel EP80579 (Tolapai) System-on-a-chip Processor 2 ports on main board, optional 2 port mezzanine card Existing 2u12 and 2u24 chassis support 2.5”, 3.5”, SAS, SATA and SSD support

Page 3: Pvma32xx series-raid

3

3000 Series Key Benefits

Up to 2x performance increase over 2000 Series

Examples under development include Neptune to Mercury to Titanium performance graphs, 12x600 versus 24x300 price performance data

Up to 40% increase over 2002 “Mercury” performance 2u24 chassis for twenty-four 15k spindles in a compact 2u design FX version will offer over 2000MB/s streaming throughput for video

applications

Page 4: Pvma32xx series-raid

4

3000 Series Key Benefits

Improved Return on Investment

Working to quantify power saving with data prior to launch Reduced operating costs with 595W 80+% efficient Bronze Rated power

supplies Drive-spin-down capability for even greater savings “No forklift” upgrade capability from 4Gb installations

Page 5: Pvma32xx series-raid

5

3000 Series Key Benefits

Continuing the Innovation Story

Expanded licensed software options for data protection Easy to setup and use with the RAIDar 2 user interface Continuing the SAS, SATA and SSD integration, SimulCache , & EcoPower Flexible design optimized for virtualized server environments

Page 6: Pvma32xx series-raid

6

Target Market

• Primary Market/Applications Disaster Recovery, remote replication Classic IT Markets (MS exchange, Database, Server Virtualization) High IOP performance (Electronic trading systems and EDI systems,

or Database applications such as Oracle and Medical PACS) Emerging Video Surveillance - low bandwidth, long term storage

• Secondary Market/ApplicationsNiche – Military, telecommunications, and mobile storage applicationsRequirements – Rugged, high IOP/MBpS and/or <600mm depth

Page 7: Pvma32xx series-raid

7

Product Features

3730 / 3720 series 2 Ports 8Gb Fibre Channel host attach per controller 2u12 and 2u24 chassis

New Technology

Intel Tolepai 1.2Ghz integrated chipset and Linux OS 2GB system RAM per controller Low cost 2u12 chassis (ULC) and 595W power supply 7 chassis JBOD support, up to 96 3.5” or 144 2.5” total drives 6Gb SAS interconnect between drives & chassis Time Delayed Drive Spin-down (v2) 1000 Maximum snapshots and AssuredRemote as new DMS SMI-S version 1.2 Bundled RAID and JBOD upgrade capability Possible FX option, streaming video improvement

Page 8: Pvma32xx series-raid

8

Benefits of 8Gb Fiber

• Digital content increases to grow at a rate of 30-40% per year• New applications and operating systems create increasing amount of

SAN traffic• Increased headroom for increased levels of data protection and tiered

migration of data• Specific benefits by vertical markets

Financial – faster transaction speeds Video – support for higher video resolutions and data rates Server virtualization pushing more bandwidth down existing SAN

links– Future proofing of SAN– 8G Fibre Channel Storage Attached Networks

provide increased headroom for future bandwidth and growth needs

Page 9: Pvma32xx series-raid

9

Fiber Channel Evolution

FC EdgeThese speeds can also be used for ISLs

‘97 ‘01 ‘05 ‘08 ‘11

20GFC

10GFC

16GFC

8GFC

4GFC

2GFC

Inter-Switch Links (ISL) provide higher core bandwidth than its sister edge speed

Edge Links are the predominate SAN inter-connect

FC Edge and FC ISL speeds compatible back and forward 2 generations with auto-negotiation!

Roadmap to 160GFC ISL!

Roadmap to 128GFC Edge!

FC ISLThese are used for ISL’s ONLY

1GFC

FCoEUsed for ISL and edge

10GFCoE

Roadmap to 100GFCoE!

FCoE uses Ethernet as it’s physical transport

Source: FCIA web site

2000 series

3000 series

3000 series

Page 10: Pvma32xx series-raid

10

Improved Customer Experience

• RAIDar 2.0 First introduced with the 2xx2 Series products - RAIDar 2.0 Provisioning and configuration wizards provide step-by-step,

intuitive screens enable users to quickly bring storage online A number of unique views provide alerts of important storage

events and warnings Users can drill down to understand the health status of a drive,

power supply, controller or any other field replaceable unit Details on health status, usage, and manufacturing details are

available Ideal for troubleshooting and proactive maintenance

3720 2u24 design

3730 2u12 design

Page 11: Pvma32xx series-raid

11

Enclosure View

Page 12: Pvma32xx series-raid

12

Configuration View

• Click on the to collapse the “Configuration View”.

• To Expand the “Configuration View” click on

• “Configuration View” shows all Logical and physical views. Vdisks Volumes Hosts Physical Enclosures

Page 13: Pvma32xx series-raid

13

3000 series Backplane

Continued evolution of the R/Evolution design

8Gb Fibre Channel via

two pre-installed

SFPs

Two optional

1Gb iSCSI ports with

the 3930/3920

Command line control via serial and new mini-USB

connections

Future function with USB

type A connection

New 8088 SAS

Expansion connecter with 6Gb support

Network management port

Page 14: Pvma32xx series-raid

14

Software Update

• 3000 Series Data Management Services Update 1,000 usable snapshots 127 snapshots per Master Volume VolumeCopy and VSS/VDS unchanged from previous products 60 Day try-n-buy for all DMS features No free snapshots included

• Drive Spindown Inactive drives can be spun down after

a user specified delay for greater power savings Scheduling and timed disk scrub enhancements planned for

later this year

Page 15: Pvma32xx series-raid

15

EcoStorTM Battery free ProtectionThe first to provide super capacitors and compact flash for battery-free cache backup• Better Data Protection

Ensures no data loss in case of power outage

• Environmentally Responsible• Eliminates battery usage and disposal

• Outstanding Financial Benefits• Reduces administrative costs• No cost for disposal of hazardous materials• Fewer FRU to track and stock• Increases profitability by reducing downtime• No time or staff costs to recover of lost or corrupt data• No performance impact during battery replacement service• Lowers total cost of ownership• Longer in-service time: 10+ years vs. a 2-3 year battery life• Eliminates 3+ Services calls within 10 year period• No Battery Replacement Costs

Reducing lifecycle costs through innovation

Page 16: Pvma32xx series-raid

Data Protection Services• AssuredSnap (Snapshots)

Point-in-time logical image of a physical volume Protect against accidental or malicious loss or

corruption of data

• AssuredCopy (Volume Copy) Complete physical and independent copy of a volume Additional protection against complete vdisk or

volume failure Mitigates multiple application I/O contention

(e.g., production vs. data mining)

• AssuredSnap/R (Remote Snapshot Replication) Remote data replication Disaster Recovery capability Centralized backup

Assured - protection against all forms of data loss

human error

computer virus

Sitedisaster

hardware or system malfunction

44%

32%

3%

7% 14%

Causes of data loss source: Ontrack, a data availability service provider

Software program malfunction

Page 17: Pvma32xx series-raid

AssuredRemoteTM

• Simple bi-directional replication software option for 3000 arrays

Now – AssuredRemote™ software option for all 3000 arrays Late March – 3000 “R” series, fully bundled remote-replication

enabled storage appliance (e.g. 3930R)• Creates new class of entry level appliance with mid-range level

features

Totally integrated – no server level application s/w required

Page 18: Pvma32xx series-raid

SimulCacheTM Technology

Disk Interconnect Cache

Processor

Processor

CacheDisk

Interconnect

Host Interconnect

SAS Drives

Controller 1 Controller 2

PCI PCI

SimulCacheCircuitry

Data simultaneously mirrored to both controllers

2: Server gets acknowledgement data was written1: Server writes

data

Host Interconnect SimulCache

Circuitry

• High Performance / Low Latency Cache Mirroring• Better Write Performance

Mirrored Writes are 92% as efficient as Non-mirrored Reduces Load On Controller Processor & I/O Bus

• Better Data Protection Redundant Controllers Insure Against Data Loss

Page 19: Pvma32xx series-raid

33203330

37203730

39203930

Host Interface iSCSI 10 Gb FC 8Gb FC 8Gb, iSCSI 1Gb

Expected Availability Now Now Now

Storage Controllers Single or Dual

Enclosure 2U12 or 2U24

Cache Memory (per controller) 2GB

Storage Controller Processor 1.2 GHz

High-Performance Mirrored Cache SimulCache: High-Performance Mirrored Cache

Cache Protection EcoStor: Battery-free Super Capacitors

Maximum Drive Count Up to 7 expansion chassis, maximum 144 drives per system

Maximum Volumes 128 per RAID set, 256 per system

Maximum Initiators 64

RAID Levels 0, 1, 3, 5, 6, 10, 50

Data Protection OptionsAssuredSnap (1000 max) & AssuredCopy, AssuredRemote 16-way

60 day try and buy

Storage Unit Management RAIDar 2.0 web console, SNMP, SMI-S

NEBS Level 3 & MIL-STD-810G Compliant

2U122U24