Purex Fume Extraction Systems

62
Brochure June 2008 “Protecting People and the Environment with Innovative Technology”

Transcript of Purex Fume Extraction Systems

BrochureJune 2008

“Protecting People andthe Environment withInnovative Technology”

- 2 -

INDEX P u r e x f u m e e x t r a c t i o n s y s t e m s

Inkjet 10-11

For continuous inkjet printers.

Inkjet Extractor (Standard) 10

Inkjet Extractor (Digital) 11

Laserex™ 14-27

For laser engraving, marking, welding and cutting.

Laserex Alpha 200 & 400 14

Laserex Alpha 400i 15

Laserex Digital 210 & 210i 16

Laserex Digital 400 & 400i 17

Laserex Digital 800i 18

Laserex Digital 1500 & 1500i 19

Laserex Digital 2000 & 2000i 20

Laserex Digital 4000 & 5000 21

For PVC applications.

Laserex 400i PVC 22

Laserex 800i PVC 23

Laserex 1500i PVC & 2000i PVC 24

Laserex 4000i PVC & 5000i PVC 25

Xbase™ work station for laser engravers

Xbase 200 & 400 26

Powerflow™ 28-33

For wave / reflow soldering and general purpose extraction.

Powerflow 210 & 210i 28

Powerflow 400 & 400i 29

Powerflow 800i 30

Powerflow 1500 & 1500i 31

Powerflow 2000 & 2000i 32

Powerflow 4000 & 5000 33

Superflow™ - Arm Systems 36-41

Extraction systems to connect to arms

Superflow 2-6 arm 36

Superflow 4-10 arm 37

Superflow 6-15 arm 38

Superflow 8-20 arm 39

Superflow 10-25 arm 40

Superflow 20-50 arm 41

Superflow™ - Tip Systems 44-47

Tip Extraction systems for soldering irons

Superflow 20, 30 or 50 tip 44

Superflow 20, 30 or 50 tip (integral type) 45

Superflow 3-10 tip system 46

FumeCube™ & FumeBuster™ 48-50

Multi purpose fume extraction systems

FumeCube single or dual arm system 48-49

FumeBuster multi purpose extraction system 50

Connection Kits and Pipework 52-59

Connect the extractor to the process

Laser connection kits 52-53

Pipework 54-55

Arms and accessories 56-57

Tip extraction kits and accessories 58-59

Cascade Box 59

Misc 60-61

Order form 60

Terms and Conditions 61

Purex International LtdPurex House, Farfield Park, ManversRotherham, S63 5DB, UKTelephone: +44 (0)1709 763000Fax: +44 (0)1709 763001Email: [email protected]

Purex Americas1290 Lakeside DriveGurnee, Illinois, IL60031USATelephone: +001 866 360 5675 Toll FreeFax: +001 866 360 5676 Toll FreeEmail: [email protected]

Websites:www.purexltd.co.ukwww.solderfume.co.ukwww.laserfume.com

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

L a s e r s • W e l d i n g • S o l d e r i n g • P r i n t i n g • C h e m i c a l s • D u s t • C l e a n r o o m s

Applications.Purex manufactures high quality fume extraction systems for a variety of applications andindustries, including:

• Laser marking, engraving, welding and cutting.• Hand soldering, tinning and potting.• Reflow soldering, wave soldering, printing and dedrossing.• Welding and brazing.• Inkjet printing.• Chemical handling and processing• Dust control• Cleanrooms and laboratories• Schools and colleges

Product Range.Purex offers machines capable of keeping a single user safe from hazardous dust andfumes ranging up to powerful centralised units capable of protecting up to 50 people.

Units are available which can extract from small, low volume production lines. Other Purexunits can handle large, high volume, 24/7 industrial lines.

Which unit do you need?Specifying the correct unit for your application is crucial to ensure the safety of personneland the speed / quality of production. Purex Design and Application Engineers havedecades of experience and are available to advise you.

Support.It is essential that support is available. Purex keeps huge stocks of replacement filters andspares to ensure that your extraction system is 100% effective. A dedicated maintenancecrew is available to respond to your needs within 24 hours and a worldwide network ofdistributors is available to support you.

Why choose Purex?Purex has the experience, products and support infrastructure to ensure that:

• The correct machine is specified first time.• The process performs at the optimum level.• Employees are protected from hazardous fumes.• Process machinery is protected from hazardous fumes.

Why do people need fume extraction systems?Many types of dust and fume are hazardous to health if inhaled. People can become permanentlysensitised to fumes which means that continued exposure, even to very small amounts of fume, maycause asthma attacks and the person affected may never be able to carry out that work again!

Because of this, employees should be protected by the best fume extraction systems available.

Why fume extraction is essential:• Prevents serious conditions such as occupational asthma and cancer.• Reduces absenteeism and improves employer relations.• Improves the working environment.

Why does the employer need fume extraction systems?Many industrial processes such as soldering, laser processing and welding all produce dust and fumeswhich are hazardous to health and which can also reduce productivity or spoil the product. Fumes canalso damage expensive production equipment and cause extensive downtime for repair and/or cleaning.

Local and International health and safety regulations require the employer to protect personnel fromhazardous dust and fumes. Failure to do so can result in expensive compensation claims and fines.

Why fume extraction is essential:• To comply with COSHH, OSHA or equivalent local regulations.• To avoid expensive health compensation claims from employees.• To comply with local environmental legislation.• To prevent damage to products or equipment.• To prevent expensive downtime.

Why do OEMs need fume extraction systems? Manufacturers of lasers, soldering, welding and other equipment need to ensure that their equipment isnot damaged and that the performance of their equipment is not impaired by dust and fumes.

Why fume extraction is essential:• OEM equipment will perform better and will not be damaged by dust and fume.• OEMs can increase sales by selling the fume extractors to their customer.• OEMs prevent production problems for their customer by supplying the fume extraction.• OEMs generate aftersales revenue by supplying filters to their customers.

HeadachesNosebleeds

SionasalCancer

SoreThroat

OccupationalAsthma

Lung Damage

RespiratoryDamage

Dermatitisand Acne

Irritation toEyes

Potential Medical Conditions Caused by Dust and Fume.

Without good extractionfumes can damageequipment, increase

reject rates and causedowntime for cleaning /

repairs.

Purex fume extractionensures maximum

productivity, excellentproduct quality andreduced downtime.

Purex fume extractionensures compliance with

local and internationalhealth and safety

legislation.

UK • T: (0)1709 763000 F: (0)1709 763001 - 4 - USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

X

4

WHY DO YOU NEED EXTRACTION?

- 5 -

System FailureExternal: If a fixed centralised systemfails then the extraction for the wholefactory can go down causing severeproblems and downtime.

Purex: Purex machines very rarely gowrong. On the rare occasion they do, thenreplacement parts can easily be fitted inminutes.

Risks and HazardsExternal: Long runs of ducting canharbour contaminants and material whichcould cause a fire risk. Ducting may alsoneed to be periodically cleaned which canbe expensive and disruptive.

Purex: Purex machines use either a shortpiece of hose or pipe to connect to theprocess which can usually be installed inminutes and which can be easily cleaned.

Expensive InstallationExternal: Ducting for external ventingmay require long runs to be installed in theceiling. This requires specialist installationusing scaffold etc. and can be verydisruptive to work and can also beexpensive.

Purex: No long ducting required, simplyconnect to the process using short lengthsof pipe or hose.

Holes in BuildingsExternal: Installing ducting usually meansthat large holes need to be specially cut ineither the walls or roof. They also need tobe sealed. All this can be expensive asspecialised contractors and equipmentare often required.

Purex: No holes required! Simply connecta hose to the process and that’s it. Done.

Purex - The better alternative to pumping fumes outside.Many people who are looking for fume extraction may consider pumping their dust and fumes outside into the atmosphere. Thismethod has many problems associated with it (see below).

Question. Venting into the environment Recirculation System (Purex)

How long will the system take to install? Several days on average. In many cases just minutes.

Will there be any disruption in the workplace?Scaffold etc may be required in several places,disrupting work for lengthy periods.

Minor if any.

Can the system be moved? Only with scaffold etc. and disruption to work. Yes. Simply unplug and push to new location.

Are holes in the building required? Yes. They need to be specially cut and sealed. No.

Are external emissions regulations a problem? Company must investigate and obey local laws. Not applicable. No problem.

Is there any energy lost e.g. heating costs?Money & Energy is wasted when heated orconditioned air is pumped outside.

No energy or heat is lost as the air is recycled.So costs are lowered.

Are there any ducting / installation costs?Expensive - as ducting needs to be purchasedand specialist installation is required.

Minimal if any, depending on process.

Are there any cleaning costs?Specialist cleaning required to prevent risk offire or contamination. Again scaffold/disruption.

Minimal if any.

Are there any decontamination costs? Specialist decontamination may be required. None.

Can fumes be drawn back into the workplace? Yes. Through windows or vents. Not possible as all fumes are locked into filters.

Could there be disputes with my neighbours? Yes. Over hazardous fumes and odours. Not applicable. No problem.

WHY RECIRCULATE?

The alternative is a Purex Recirculating Filter System. The Purex extractor captures dust and fumes in specialised filters and returnsclean, purified air to the workplace.

The Purex extractor is simply connected next to the process. If the process moves, the extractor easily moves with it.

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

WHY CHOOSE PUREX?

Flow ControlQ: As a filter gets blocked the airflowbegins to fall. This affects product qualityand production and fumes can leak intothe workplace. How do I prevent this?

A: Purex systems incorporate ‘AutomaticFlow Control’ which speeds up the motorwhen required to maintain a constantairflow throughout the life of the filter.

Gas & Particle SensorsQ: My employees could be exposed tohazardous fumes if a filter is damaged ornot fitted correctly. How do I make surethis doesn’t happen?

A: Purex ‘Digital’ systems use sensors toconstantly monitor exhaust air so ifhazardous fumes escape the filters thenaudible and visual alarms are triggered towarn employees and keep them safe.

22

0

0

°C

mm/wg

Pre-filter lifeQ: I have been told that some pre-filtersdo not last very long and so running someextraction machines is expensive. How doPurex cut down on this cost?

A: Purex patented ‘Labyrinth’ pre-filters aremade from deep multi-grade media whichhas tremendous dust holding capacity,meaning they capture more dust whencompared to other filters. Also, they fold flatand weigh very little, so the carriage costcan be half that of other filters.

Downtime to changefiltersQ: Changing filters on my currentextractor is a hassle as I have to changethem frequently and it’s not easy to do.How can this be made easier with Purex?

A: Purex filters last much longer and sodo not need to be changed as often. Also,changing them couldn’t be simpler - stopthe machine, open the door on the frontand change the filter. Simple.

Extractor Noise ProblemQ: Some extractors run on full power allthe time and are very noisy. This couldannoy and distract my employees. Howcan this be prevented with a Purex?

A: Purex machines use blowers which areextremely quiet. Flow Control machinesalso run slowly at first and only increasespeed to overcome filter blockage. Thisfeature also makes filters last even longer.

The extractor is too big.Q: I only have a small space for anextractor to fit into. Plus, once it isinstalled I don’t want to have to move it tochange filters or for maintenance.

A: Purex extractors are as small aspossible (e.g. less than 500mm2 !) Allfilters are changed from the front inseconds and maintenence access is fromthe top with few or even no tools requiredto carry out most part replacements.

LASEREXD I G I T A L

LASEREXa l p h a

885m

m

465mm

465mm

465mm

Ø82mm

FUME EXTRACTION SYSTEMSPUREX

PVC ProblemsQ: How do I stop PVC fumes corrodingmy extractor? I cannot find a solutionanywhere.

A: Purex PVC extractors aremanufactured from specialist materialsand are coated to prevent corrosion.Hundreds of Purex PVC machines are outin the field dealing with this problematicmaterial.

How do I set the correctairflow?Q: Many machines I have seen run at afixed speed - is this a problem? Also howdo I set the correct airflow?

A: The correct airflow can be set on aPurex machine quickly and easily. Filtersalso last longer if the machine is set upcorrectly and does not run at 100% all thetime. (see flow control)

Purex - The most cost effective fully featured extractors available.For more than 20 years, Purex have listened to the concerns of their customers and have designed extractors to solve the everydayproblems that customers face. The latest ‘Digital’ range of machines is the pinnacle of this design process.

- 6 -

Q & A

PVC

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 7 -

PUREX ‘DIGITAL’ FEATURES

Particulate FilterLife Monitor

Chemical FilterLife Monitor

ParticulateLeak Sensor

Actual Airflow

Target Airflow

LASEREXD I G I T A L

22

0

0

°C

m3/ hr

FUME EXTRACTION SYSTEMSPUREX

We’ve designed the ‘Digital’ with you in mind.The latest ‘Digital’ extraction systems have some very powerful features built in, such as - Automatic Flow Control, Gas & ParticleSensors, Electronic Interfacing, Filter Blocked Warnings, Filter Exhausted Warning, Precise Electronic Airflow Readings, TemperatureWarnings, Real Time System Monitoring and Filter Change Icons.

Control Panel& Graphic Display

Internal Components

Quick Change MainFilter

Patented Labyrinth™pre-filter

Castors for mobility

All this automatically works behind thescenes... All you have to do is ...

• Plug the machine in...• Connect to the process...• Set the airflow...• and that’s it! Your Purex will look after the rest.

User friendly engineering designedto save you money.Purex ‘Digital’ fume extractors are designed to give you thelongest filter life and one of the most comprehensivemonitoring systems available.

Money saving features:• Flow Control System - Constantly monitors airflow and

adjusts motor speed automatically to keep the extractionrate at the level you have set. This extends filter lifebecause particles are not compacted into filters at highspeeds.

It also ensures that fumes are extracted correctlythroughout the life of the filter. This ensures productquality and prevents downtime and expensive damage toequipment caused by debris.

• Labyrinth™ - patented pre-filters have exceptional lifeand work with a wide variety of dust and fumes. Thismeans you buy fewer filters and a single machine cancover a variety of tasks. (Particularly useful for engravinglasers.)

• HEPA Filtration - In independent tests, Purex mainHEPA filters removed 99.997% of all particles above 0.3microns and 95% down to 0.01 microns. A chemical layeris also used to remove hazardous gas from theairstream.

• Blowers - powerful high pressure motors pull air throughpartially blocked filters, increasing filter life even furtherand reducing your costs.

• Reverse Airflow principle forces larger particles out ofthe airstream which extends filter life even further.

• Air Equalisation - Special plates are used to slow theairflow to the speed at which the filters are most effective.This prevents premature HEPA blockage and ensuresgases can be adsorbed in the chemical layer. If air wasallowed to pass through the chemical layer too quicklythen hazardous gas would enter the workplaceunfiltered!

• Unburstable Filters - All Purex filters are speciallypressure tested to ensure that they will not fail in service.

• Hood / Extraction and Pipework Design - Purexengineers ensure you get the right connection set up withyour machine to ensure it operates at peak efficiency.

Motor Run Icon

Filter ChangeIndicators

MachineTemperature

Reverse Airflow SystemProtects the HEPA filter byremoving large particles.

HEPA Element.

Chemical Element.

Pure, clean air returned tothe workplace.

Air equalisation andreinforcing plates

NEW

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 8 -

EQUIPMENT INTERFACING

www.laserfume.comSpecific Information on theLaserex range.

www.solderfume.co.ukSpecific Information on Purexmachines for solder fume.

.

www.purexltd.co.ukInformation on the whole Purexrange.

WEB SITE HELP

Purex ‘Digital’ System - plug and play machinery interface.Purex systems can interface with other machinery such as lasers, reflow ovens, and robots to deliver more control.

Synchronised START / STOP:START / STOP the Purex ‘Digital’ system when you START /STOP your machine to make sure that fumes are alwaysextracted when machinery is running.

Automatic run on:The Purex ‘Digital’ system can continue to run for a specifiedtime (e.g. 5 minutes) after your machinery is stopped to ensurethat all lingering fumes are captured.

Filter Change Warnings:The Purex ‘Digital’ system can tell your machinery when newfilters are required or if there is a problem with the system.Choose to shut your machinery down or simply generate analert.

Beacons:The Purex ‘Digital’ system can be linked to a beacon so that anyalarms are highly visible. (Can also link to other types of alarm.)

Connectors:Several different connection types are available to fit yourmachinery.

LASEREXD I G I T A L LA

SER

Laser

SOLDER

FUME EXTRACTION SYSTEMSPUREX

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

IInnkkjjeettIInnkkjjeett VVaappoouurr EExxttrraaccttiioonn aanndd

FFii llttrraattiioonn SSyysstteemmss

FUME EXTRACTION SYSTEMSPUREX

- 10 -

Inkjet Extractor I n k j e t v a p o u r e x t r a c t i o n s y s t e m

Inkjet 200 Inkjet 400Description Code:230V 0AL2104120V 0AL2105

Supplied with:1 x Main filter1 x Labyrinth pre-filter

Supplied with:1 x Main filter1 x Labyrinth pre-filter

Description Code:230V 0AL4105120V 0AL4106

Upgrade Pack-1Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomesblocked, the closed loop flow control systemautomatically adjusts the speed of the motor tomaintain a constant airflow throughout the life ofthe filter making the filter last longer.

Code: 100280Increase filter lifeand gain precise

control.

Interface with thelaser for greater

flexibility.

Upgrade Pack-2 (Requires Upgrade Pack 1)

ON/OFF Control:Extraction unit starts/stops when the Inkjet Printeris switched ON/OFF.

Filter Blocked Warning:A signal is sent to the Inkjet Printer to trigger analert or to shut the Inkjet Printer down.Code: 100269

LASEREXD I G I T A L

LASEREXa l p h a

LA

SE

R

FUME EXTRACTION SYSTEMSPUREX

Replacement Filters Replacement Parts

Labyrinth Pre-Filter (All models)Description: Code:F6 (std) 111085

PCBCode:(Basic Machine)400005(For machines with upgrade Pk1)400048

BlowerDescription: Code:230V Inkjet 200 300170/T120V Inkjet 200 300174/T230V Inkjet 400 300172/T120V Inkjet 400 300173/TNB: Previous 120V machines used the 230V blowers above witha factory fitted transformer. Check the serial number of yourmachine with Purex prior to order of replacements.

Optional Connection Kit1 x Twin manifold2 x 3m of 51mm flexible hose (anti static black)4 x 51mm cuffs (anti static black)2 x Clamp bench brackets2 x 38mm stainless steel flexible arms2 x Delta cowls (1 x 25mm & 1 x 38mm)

Code:100027

Custom Connection Kits

Other connection kits are available for all types and models of inkjets. Wealso offer a design service for custom installations.

SpecificationUnit Inkjet 200 Inkjet 400Voltage 230V ±10% 120V ±10% 230V ±10% 120V ±10%Part number 0AL2104 0AL2105 0AL4105 0AL4106Wattage 0.14 kW 0.14 kW 0.204 kW 0.255 kWSound rating 45 dBA 45 dBA 45 dBA 45 dBAMax flowrate 200 m3/hr 125 cf/m 400 m3/hr 235 cf/mFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 885 mm 885 mm 885 mm 885 mmCabinet width (not inc hose) 465 mm 465 mm 465 mm 465 mmCabinet depth (not inc hose) 465 mm 465 mm 465 mm 465 mmCabinet weight (inc filters) 41 Kg 41 Kg 41 Kg 41 KgHose (recommended) 51 mm 51 mm 51 mm 51 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Main Filters (All models)Description: Code:Solvent-Lock filter 113513

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 11 -

Inkjet Extractor (Digital) I n k j e t v a p o u r e x t r a c t i o n s y s t e m

Inkjet (Digital) 200 Inkjet (Digital) 400Description Code:230V 0AL2108120V 0AL2109

Supplied with:1 x Main filter1 x Labyrinth pre-filter

Supplied with:1 x Main filter1 x Labyrinth pre-filter

Description Code:230V 0AL4111120V 0AL4112

Replacement Filters Replacement Parts

Labyrinth Pre-Filter (All models)Description: Code:F6 (std) 111085

PCBCode:400001 (Digital Machine)FMUCode:400440 (Digital Machine)

BlowerDescription: Code:230V Inkjet 200 300170/T120V Inkjet 200 300174/T230V Inkjet 400 300172/T120V Inkjet 400 300173/TNB: Previous 120V machines used the 230V blowers above witha factory fitted transformer. Check the serial number of yourmachine with Purex prior to order of replacements.

Optional Connection Kit1 x Twin manifold2 x 3m of 51mm flexible hose (anti static black)4 x 51mm cuffs (anti static black)2 x Clamp bench brackets2 x 38mm stainless steel flexible arms2 x Delta cowls (1 x 25mm & 1 x 38mm)

Code:100027

Custom Connection Kits

Other connection kits are available for all types and models of inkjets. Wealso offer a design service for custom installations.

SpecificationUnit Inkjet 200 Inkjet 400Voltage 230V ±10% 120V ±10% 230V ±10% 120V ±10%Part number 0AL2108 0AL2109 0AL4111 0AL4112Wattage 0.14 kW 0.14 kW 0.204 kW 0.255 kWSound rating 45 dBA 45 dBA 45 dBA 45 dBAMax flowrate 200 m3/hr 125 cf/m 400 m3/hr 235 cf/mFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 885 mm 885 mm 885 mm 885 mmCabinet width (not inc hose) 465 mm 465 mm 465 mm 465 mmCabinet depth (not inc hose) 465 mm 465 mm 465 mm 465 mmCabinet weight (inc filters) 41 Kg 41 Kg 41 Kg 41 KgHose (recommended) 51 mm 51 mm 51 mm 51 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Main Filters (All models)Description: Code:Solvent-Lock filter 113513

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a particle filter starts to block so thata replacement can be acquired and downtime can beavoided. The display also shows which filter may needattention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Inkjet Interface Kit: (Optional)Extraction unit starts/stops when the inkjet is switchedON/OFF. Alerts are signalled to the inkjet. A timer makesthe extractor briefly run on after the inkjet is switched off toensure all fume is removed.Code: 100269

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 12 -

Notes

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

LLaasseerreexx™™ &&XXbbaassee™™

LLaasseerr FFuummee EExxttrraaccttiioonn aanndd FFii llttrraattiioonnSSyysstteemmssFUME EXTRACTION SYSTEMS

PUREX

- 14 -

Laserex Alpha™ L a s e r f u m e e x t r a c t i o n s y s t e m

Laserex Alpha™ 200 Laserex Alpha™ 400Description Code:230V 0AL2102120V 0AL2103

Supplied with:1 x Main filter1 x Labyrinth pre-filter

Supplied with:1 x Main filter1 x Labyrinth pre-filter

Description Code:230V 0AL4102120V 0AL4103

Upgrade Pack-1Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomesblocked, the closed loop flow control systemautomatically adjusts the speed of the motor tomaintain a constant airflow throughout the life ofthe filter making the filter last longer.

Code: 100276Increase filter lifeand gain precise

control.

Interface with thelaser for greater

flexibility.

Upgrade Pack-2ON/OFF Control:Extraction unit starts/stops when the laser isswitched ON/OFF.

Filter Blocked Warning:A signal is sent to the laser to trigger a laser alertor to shut the laser down.Code: 100269

LASEREXD I G I T A L

LASEREXa l p h a

LA

SE

R

FUME EXTRACTION SYSTEMSPUREX

Replacement Filters Replacement PartsLabyrinth Pre-Filter (All models)Description: Code:F6 (std) 111085F8/F9 Composite 111095

PCB (All models)Code:400048

BlowerDescription: Code:230V Alpha 200 300170/T120V Alpha 200 300174/T230V Alpha 400 300172/T120V Alpha 400 300173/T

NB: Previous 120V machines used the 230V blowers above witha factory fitted transformer. Check the serial number of yourmachine with Purex prior to order of replacements.

Optional Connection Kit1 x Reducer 80-51mm1 x 3m of 51mm flexible hose (black)2 x 51mm cuffs (black)

Code:100032

Custom Connection Kits

Other connection kits are available for all typesand models of lasers. We also offer a design

service for custom installations.

Laser

SpecificationUnit Laserex Alpha 200 Laserex Alpha 400Voltage 230V ±10% 120V ±10% 230V ±10% 120V ±10%Part number 0AL2102 0AL2103 0AL4102 0AL4103Wattage 0.14 kW 0.14 kW 0.204 kW 0.255 kWSound rating 45 dBA 45 dBA 45 dBA 45 dBAMax flowrate 200 m3/hr 125 cf/m 400 m3/hr 235 cf/mFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 885 mm 885 mm 885 mm 885 mmCabinet width (not inc hose) 465 mm 465 mm 465 mm 465 mmCabinet depth (not inc hose) 465 mm 465 mm 465 mm 465 mmCabinet weight (inc filters) 41 Kg 41 Kg 41 Kg 41 KgHose (recommended) 51 mm 51 mm 51 mm 51 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Main Filters (All models)Description: Code:HEPA/Chemical (std) 113505HEPA/Twin Chemical 113579HEPA/Chemical Cleanroom 113512

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 15 -

Laserex Alpha™ 400i L a s e r f u m e e x t r a c t i o n s y s t e m

Supplied with:1 x Main filter1 x Labyrinth pre-filter

Description Code:230V 0AL4113120V 0AL4114

Upgrade Pack-1Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomesblocked, the closed loop flow control systemautomatically adjusts the speed of the motor tomaintain a constant airflow throughout the life ofthe filter making the filter last longer.

Code: 100276Increase filter lifeand gain precise

control.

Interface with thelaser for greater

flexibility.

Upgrade Pack-2ON/OFF Control:Extraction unit starts/stops when the laser isswitched ON/OFF.

Filter Blocked Warning:A signal is sent to the laser to trigger a laser alertor to shut the laser down.Code: 100269

LASEREXD I G I T A L

LASEREXa l p h a

LA

SE

R

FUME EXTRACTION SYSTEMSPUREX

Replacement Filters Replacement PartsLabyrinth Pre-Filter (All models)Description: Code:F6 (std) 111057F8/F9 Composite 111097

PCB (All models)Code:400048

BlowerDescription: Code:230V Alpha 400i 300172/T120V Alpha 400i 300173/T

NB: Previous 120V machines used the 230V blowers above witha factory fitted transformer. Check the serial number of yourmachine with Purex prior to order of replacements.

Optional Connection Kit1 x Reducer 80-51mm1 x 3m of 51mm flexible hose (black)2 x 51mm cuffs (black)

Code:100032

Custom Connection Kits

Other connection kits are available for all typesand models of lasers. We also offer a design

service for custom installations.

Laser

SpecificationUnit Laserex Alpha 400iVoltage 230V ±10% 120V ±10%Part number 0AL4113 0AL4114Wattage 0.204 kW 0.255 kWSound rating 45 dBA 45 dBAMax flowrate 400 m3/hr 235 cf/mFrequency 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 1070 mm 1070 mmCabinet width (not inc hose) 455 mm 455 mmCabinet depth (not inc hose) 480 mm 480 mmCabinet weight (inc filters) 55 Kg 55 KgHose (recommended) 51 mm 51 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Main Filters (All models)Description: Code:HEPA/Chemical (std) 113505HEPA/Twin Chemical 113579HEPA/Chemical Cleanroom 113512

Laserex Alpha™ 400i

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.The display also shows which filter may need attention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Laserex 210 & 210i L a s e r f u m e e x t r a c t i o n s y s t e m

Laserex 210 Laserex 210iDescription: Code:230V 0LX2100D120V 0LX2101D

Supplied with:1 x Main filter1 x Pre-filter pad1 x Connection Kit (100043)

Supplied with:1 x Main filter1 x Labyrinth pre-filter1 x Connection Kit (100043)

Description: Code:230V 0LX2110D120V 0LX2121D

Replacement Filters Replacement PartsLabyrinth Pre-Filter (210i only)Description: Code:F6 (std) 111057F8/F9 Composite 111097

PCB (All models)Code:400001

Pre-Filter Pad (210 only)Description: Code:Pack of 4 202260

Main Filters (All models)Description: Code:HEPA/Chemical (std) 113505HEPA/Twin Chemical 113579HEPA/Chemical Cleanroom 113512

BlowerDescription: Code:(230V) 300593/T(120V) 300592/T

FMU (All models)Description: Code:Filter Monitor Unit 400440

Includes Standard Connection Kit1 x Reducer 80-51mm1 x 6m of 51mm flexible hose (black)2 x 51mm cuffs (black)

Code:100043

Custom Connection Kits

Other connection kits are available for all typesand models of lasers. We also offer a design

service for custom installations.

Laser

SpecificationUnit Laserex 210 Laserex 210iVoltage 230V ±10% 120V ±10% 230V ±10% 120V ±10%Part number 0LX2100D 0LX2101D 0LX2110D 0LX2121DWattage 0.45 kW 0.45 kW 0.45 kW 0.45 kWSound rating 52 dBA 55 dBA 52 dBA 55 dBAMax flowrate 210 m3/hr 140 cf/m 210 m3/hr 140 cf/mFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 720 mm 720 mm 1070 mm 1070 mmCabinet width (not inc hose) 455 mm 455 mm 455 mm 455 mmCabinet depth (not inc hose) 480 mm 480 mm 480 mm 480 mmCabinet weight (inc filters) 47 Kg 47 Kg 55 Kg 55 KgHose (recommended) 51 mm 51 mm 51 mm 51 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

- 16 -

Laser Interface Kit: (Optional)Extraction unit starts/stops when the laser is switchedON/OFF. Alerts are signalled to the laser. A timer makesthe extractor briefly run on after the laser is switched off toensure all fume is removed.Code: 100269

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 17 -

Laserex 400 & 400i L a s e r f u m e e x t r a c t i o n s y s t e m

Laserex 400 Laserex 400iDescription: Code:230V 0LX4000D120V 0LX4001D

Supplied with:1 x Main filter1 x Pre-filter pad1 x Connection Kit (100043)

Supplied with:1 x Main filter1 x Labyrinth pre-filter1 x Connection Kit (100043)

Description: Code:230V 0LX4010D120V 0LX4013D

Replacement Filters Replacement PartsLabyrinth Pre-Filter (400i only)Description: Code:F6 (std) 111057F8/F9 Composite 111097

PCB (All models)Code:400001

Pre-Filter Pad (400 only)Description: Code:Pack of 4 202260

Main Filters (All models)Description: Code:HEPA/Chemical (std) 113505HEPA/Twin Chemical 113579HEPA/Chemical Cleanroom 113512

BlowerDescription: Code:(230V) 300595/T(120V) 300594/T

FMU (All models)Description: Code:Filter Monitor Unit 400440

Includes Standard Connection Kit1 x Reducer 80-51mm1 x 6m of 51mm flexible hose (black)2 x 51mm cuffs (black)

Code:100043

Custom Connection Kits

Other connection kits are available for all typesand models of lasers. We also offer a design

service for custom installations.

Laser

SpecificationUnit Laserex 400 Laserex 400iVoltage 230V ±10% 120V ±10% 230V ±10% 120V ±10%Part number 0LX4000D 0LX4001D 0LX4010D 0LX4013DWattage 1.2 kW 1.1 kW 1.2 kW 1.1 kWSound rating 52 dBA 55 dBA 52 dBA 55 dBAMax flowrate 460 m3/hr 270 cf/m 460 m3/hr 270 cf/mFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 720 mm 720 mm 1070 mm 1070 mmCabinet width (not inc hose) 455 mm 455 mm 455 mm 455 mmCabinet depth (not inc hose) 480 mm 480 mm 480 mm 480 mmCabinet weight (inc filters) 47 Kg 47 Kg 55 Kg 55 KgHose (recommended) 51 mm 51 mm 51 mm 51 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.The display also shows which filter may need attention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Laser Interface Kit: (Optional)Extraction unit starts/stops when the laser is switchedON/OFF. Alerts are signalled to the laser. A timer makesthe extractor briefly run on after the laser is switched off toensure all fume is removed.Code: 100269

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

UK • T: (0)1709 763000 F: (0)1709 763001 - 18 - USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

Laserex 800i L a s e r f u m e e x t r a c t i o n s y s t e m

Laserex 800i (2-Tier) Laserex 800i (3-Tier)Description: Code:230V 080502D120V 080503D

Supplied with:1 x Main filter1 x Labyrinth pre-filter

Supplied with:2 x Main filters1 x Labyrinth pre-filter

Description: Code:230V 080501D120V 080500D

Replacement Filters Replacement PartsLabyrinth Pre-FilterDescription: Code:F6 (2-Tier std) 111098F8/9 Composite (2-Tier) 111004F8/9 Composite (3-Tier std) 111101

PCB (All models)Code:400001

Main FiltersDescription: Code:(2-Tier)HEPA/Chemical (std) or.. 113652HEPA/Twin Chemical 113660(3-Tier)HEPA (std) and.. 113650Chemical (std) 113651

Blower (800i machines have 2 blowers)Description: Code:(230V) 300595/T(120V) 300594/T

FMU (All models)Description: Code:Filter Monitor Unit 400440

Custom Connection Kit

Connection kits are available for all types and models of lasers.We also offer a design service for custom installations. See accessories section.

SpecificationUnit Laserex 800i (2-Tier) Laserex 800i (3-Tier)Voltage 230V ±10% 120V ±10% 230V ±10% 120V ±10%Part number 080502D 080503D 080501D 080500DWattage 2.4 kW 2.2 kW 2.4 kW 2.2 kWSound rating 65 dBA 65 dBA 65 dBA 65 dBAMax flowrate 800 m3/hr 471 cf/m 800 m3/hr 471 cf/mFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 1150 mm 1150 mm 1150 mm 1150 mmCabinet width (not inc hose) 540 mm 540 mm 540 mm 540 mmCabinet depth (not inc hose) 670 mm 670 mm 670 mm 670 mmCabinet weight (inc filters) 80 Kg 80 Kg 80 Kg 80 KgHose (recommended) 100 mm 100 mm 100 mm 100 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.The display also shows which filter may need attention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Laser Interface Kit: (Optional)Extraction unit starts/stops when the laser is switchedON/OFF. Alerts are signalled to the laser. A timer makesthe extractor briefly run on after the laser is switched off toensure all fume is removed.Code: 100269

- 19 -

Laserex 1500 & 1500i L a s e r f u m e e x t r a c t i o n s y s t e m

Laserex 1500 Laserex 1500iDescription: Code:230V 0LX1500D120V 0LX1501D

Supplied with:1 x Main filter1 x Pre-filter pad

Supplied with:1 x Main filter1 x Labyrinth pre-filter

Description: Code:230V 0LX1510D120V 0LX1511D

Replacement Filters Replacement PartsLabyrinth Pre-Filter (1500i only)Description: Code:F6 (std) 111037F8/F9 Composite 111099

PCB (All models)Code:400001

Pre-Filter Pad (1500 only)Description: Code:Pack of 4 200280

Main Filters (All models)Description: Code:HEPA/Chemical (std) 110615HEPA/Twin Chemical 110614

BlowerDescription: Code:(230V / 120V) 300603/TThese blowers operate through a factory fittedtransformer in 120V machines.

FMU (All models)Description: Code:Filter Monitor Unit 400440

SpecificationUnit Laserex 1500 Laserex 1500iVoltage 230V ±10% 120V ±10% 230V ±10% 120V ±10%Part number 0LX1500D 0LX1501D 0LX1510D 0LX1511DWattage 1.5 kW 1.5 kW 1.5 kW 1.5 kWSound rating 59 dBA 59 dBA 59 dBA 59 dBAMax flowrate 1700 m3/hr 700 cf/m 1700 m3/hr 700 cf/mFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 1100 mm 1100 mm 1400 mm 1400 mmCabinet width (not inc hose) 690 mm 690 mm 690 mm 690 mmCabinet depth (not inc hose) 710 mm 710 mm 710 mm 710 mmCabinet weight (inc filters) 112 Kg 112 Kg 134 Kg 134 KgHose (recommended) 150 mm 150 mm 150 mm 150 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Custom Connection Kit

Connection kits are available for all types and models of lasers.We also offer a design service for custom installations. See accessories section.

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.The display also shows which filter may need attention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Laser Interface Kit: (Optional)Extraction unit starts/stops when the laser is switchedON/OFF. Alerts are signalled to the laser. A timer makesthe extractor briefly run on after the laser is switched off toensure all fume is removed.Code: 100269

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 20 -UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

Laserex 2000 & 2000i L a s e r f u m e e x t r a c t i o n s y s t e m

Laserex 2000 Laserex 2000iDescription: Code:400V 0LX2000D220V 0LX2001D

Supplied with:1 x Main filter1 x Pre-filter pad

Supplied with:1 x Main filter1 x Labyrinth pre-filter

Description: Code:400V 0LX2010D220V 0LX2011D

Replacement Filters Replacement PartsLabyrinth Pre-Filter (2000i only)Description: Code:F6 (std) 111037F8/F9 Composite 111099

PCB (All models)Code:400001

Pre-Filter Pad (2000 only)Description: Code:Pack of 4 200280

Main Filters (All models)Description: Code:HEPA/Chemical (std) 110615HEPA/Twin Chemical 110614

BlowerDescription: Code:(220V / 400V) 300612/T

FMU (All models)Description: Code:Filter Monitor Unit 400440

SpecificationUnit Laserex 2000 Laserex 2000iVoltage 400V 3ph + N 220V 3ph 400V 3ph + N 220V 3phPart number 0LX2000D 0LX2001D 0LX2010D 0LX2011DWattage 3.0 kW 3.0 kW 3.0 kW 3.0 kWSound rating 59 dBA 59 dBA 59 dBA 59 dBAMax flowrate 2200 m3/hr 1300 cf/m 2200 m3/hr 1300 cf/mFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 1100 mm 1100 mm 1400 mm 1400 mmCabinet width (not inc hose) 690 mm 690 mm 690 mm 690 mmCabinet depth (not inc hose) 710 mm 710 mm 710 mm 710 mmCabinet weight (inc filters) 112 Kg 112 Kg 148 Kg 148 KgHose (recommended) 150 mm 150 mm 150 mm 150 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Custom Connection Kit

Connection kits are available for all types and models of lasers.We also offer a design service for custom installations. See accessories section.

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.The display also shows which filter may need attention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Laser Interface Kit: (Optional)Extraction unit starts/stops when the laser is switchedON/OFF. Alerts are signalled to the laser. A timer makesthe extractor briefly run on after the laser is switched off toensure all fume is removed.Code: 100269

- 21 -

Laserex 4000 & 5000 L a s e r f u m e e x t r a c t i o n s y s t e m

Laserex 4000 Laserex 5000Description: Code:400V 0LX4440D220V 0LX4441D

Supplied with:2 x Main filters and1 x Labyrinth pre-filteror 1 x Pleated bag filter with 5 x pre-filter pads* Specify filter combinations and PCB type onordering

Supplied with:2 x Main filters and1 x Labyrinth pre-filteror 1 x Pleated bag filter with 5 x pre-filter pads* Specify filter combinations and PCB type onordering

Description: Code:400V 0LX5550D220V 0LX5551D

Replacement Filters Replacement Parts(Option-1) Labyrinth Pre-FilterDescription: Code:F8 (std) 111072F8/F9 Composite 111006

PCB (All models)Code:400000or 400001

(Option-2) Pleated Bag Filter & Pre-Filter PadDescription: Code:Pre-filter Pad (Pack of 4) 200310Pleated Bag Filter 111144

Main FiltersDescription: Code:HEPA (std) 110633Chemical (std) 110627

BlowerDescription: Code:400V Laserex 4000 300614/T220V Laserex 4000 300614/T400V Laserex 5000 300615/T220V Laserex 5000 300615/T

FMU (All models)Description: Code:Filter Monitor Unit 400440

SpecificationUnit Laserex 4000 Laserex 5000Voltage 400V 3ph + N 220V 3ph 400V 3ph + N 220V 3phPart number 0LX4440D 0LX4441D 0LX5550D 0LX5551DWattage 5.5 kW 5.5 kW 7.5 kW 7.5 kWSound rating 59 dBA 59 dBA 59 dBA 59 dBAMax flowrate 4000 m3/hr 2400 cf/m 5000 m3/hr 2940 cf/mFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 1810 mm 1810 mm 1810 mm 1810 mmCabinet width (not inc hose) 1210 mm 1210 mm 1210 mm 1210 mmCabinet depth (not inc hose) 885 mm 885 mm 885 mm 885 mmCabinet weight (inc filters) 340 Kg 340 Kg 340 Kg 340 KgHose (recommended) 150/200 mm 150/200 mm 150/200 mm 150/200 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Custom Connection Kit

Connection kits are available for all types and models of lasers.We also offer a design service for custom installations. See accessories section.

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.The display also shows which filter may need attention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Laser Interface Kit: (Optional)Extraction unit starts/stops when the laser is switchedON/OFF. Alerts are signalled to the laser. A timer makesthe extractor briefly run on after the laser is switched off toensure all fume is removed.Code: 100269

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 22 -UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

Laserex 400i PVC P V C f u m e e x t r a c t i o n s y s t e m

Laserex 400i PVC

Supplied with:1 x Main filter1 x Labyrinth PVC pre-filter1 x Chemical Absorbent Pad1 x Connection Kit (100043C)

Description: Code:230V 0PV4010D120V 0PV4013D

Replacement Filters Replacement Parts

Labyrinth PVC Pre-FilterDescription: Code:F8/F9 Composite 111097

PCB (All models)Code:400001

Chemical Absorbent PadDescription: Code:PVC Pad (Pack of 4) 200261

Main Filters (All models)Description: Code:HEPA/PVC Chemical 113498

BlowerDescription: Code:(230V) 400i PVC 300595/T(120V) 400i PVC 300594/T

FMU (All models)Description: Code:Filter Monitor Unit 400440

SpecificationUnit Laserex 400i PVCVoltage 230V ±10% 120V ±10%Part number 0PV4010D 0PV4013DWattage 1.2 kW 1.1 kWSound rating 52 dBA 55 dBAMax flowrate 460 m3/hr 270 cf/mFrequency 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 1181 mm 1181 mmCabinet width (not inc hose) 455 mm 455 mmCabinet depth (not inc hose) 480 mm 480 mmCabinet weight (inc filters) 71 Kg 71 KgHose (recommended) 51 mm 51 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Includes Standard Connection Kit1 x Reducer 80-51mm1 x 6m of 51mm flexible hose (black)2 x 51mm cuffs (black)

Code:100043C

Custom Connection Kits

Other connection kits are available for all typesand models of lasers. We also offer a design

service for custom installations.

Laser

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.The display also shows which filter may need attention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Laser Interface Kit: (Optional)Extraction unit starts/stops when the laser is switchedON/OFF. Alerts are signalled to the laser. A timer makesthe extractor briefly run on after the laser is switched off toensure all fume is removed.Code: 100269

- 23 -UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

Laserex 800i PVC L a s e r f u m e e x t r a c t i o n s y s t e m

Laserex 800i PVC (2-Tier) Laserex 800i PVC (3-Tier)Description: Code:230V 080502DPVC120V 080503DPVC

Supplied with:1 x Main filter1 x Labyrinth pre-filter1 x Chemical Absorbent Pad

Supplied with:2 x Main filters1 x Labyrinth pre-filter1 x Chemical Absorbent Pad

Description: Code:230V 080501DPVC120V 080500DPVC

Replacement Filters Replacement PartsLabyrinth Pre-FilterDescription: Code:F8/9 Composite (2-Tier) 111004F8/9 Composite (3-Tier std) 111101

PCB (All models)Code:400001

Main FiltersDescription: Code:(2-Tier)HEPA/Chemical (std) or.. 113664(3-Tier)HEPA (std) and.. 113665Chemical (std) 113666

Blower (800i machines have 2 blowers)Description: Code:(230V) 300595/T(120V) 300594/T

FMU (All models)Description: Code:Filter Monitor Unit 400440

Custom Connection Kit

Connection kits are available for all types and models of lasers.We also offer a design service for custom installations. See accessories section.

SpecificationUnit Laserex 800i PVC (2-Tier) Laserex 800i PVC (3-Tier)Voltage 230V ±10% 120V ±10% 230V ±10% 120V ±10%Part number 080502DPVC 080503DPVC 080501DPVC 080500DPVCWattage 2.4 kW 2.2 kW 2.4 kW 2.2 kWSound rating 65 dBA 65 dBA 65 dBA 65 dBAMax flowrate 800 m3/hr 471 cf/m 800 m3/hr 471 cf/mFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 1150 mm 1150 mm 1150 mm 1150 mmCabinet width (not inc hose) 540 mm 540 mm 540 mm 540 mmCabinet depth (not inc hose) 670 mm 670 mm 670 mm 670 mmCabinet weight (inc filters) 80 Kg 80 Kg 80 Kg 80 KgHose (recommended) 100 mm 100 mm 100 mm 100 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.The display also shows which filter may need attention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Laser Interface Kit: (Optional)Extraction unit starts/stops when the laser is switchedON/OFF. Alerts are signalled to the laser. A timer makesthe extractor briefly run on after the laser is switched off toensure all fume is removed.Code: 100269

Chemical Absorbent PadDescription: Code:PVC Pad (Pack of 4) 200262for 2 & 3 Tier machines

- 24 -UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

Laserex 1500i & 2000i PVC L a s e r f u m e e x t r a c t i o n s y s t e m

Laserex 1500i PVC Laserex 2000i PVCDescription: Code:230V 0PV1510D120V 0PV1511D

Supplied with:1 x Main filter1 x Labyrinth PVC pre-filter1 x Chemical Absorbent Pad

Supplied with:1 x Main filter1 x Labyrinth PVC pre-filter1 x Chemical Absorbent Pad

Description: Code:400V 0PV2010D220V 0PV2011D

SpecificationUnit Laserex 1500i PVC Laserex 2000i PVCVoltage 230V ±10% 120V ±10% 400V 3ph + N 220V 3phPart number 0PV1510D 0PV1511D 0PV2010D 0PV2011DWattage 1.5 kW 1.5 kW 3.0 kW 3.0 kWSound rating 59 dBA 59 dBA 59 dBA 59 dBAMax flowrate 1700 m3/hr 700 cf/m 2200 m3/hr 1300 cf/mFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 1400 mm 1400 mm 1400 mm 1400 mmCabinet width (not inc hose) 690 mm 690 mm 690 mm 690 mmCabinet depth (not inc hose) 710 mm 710 mm 710 mm 710 mmCabinet weight (inc filters) 147 Kg 147 Kg 163 Kg 163 KgHose (recommended) 150 mm 150 mm 150 mm 150 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Custom Connection Kit

Connection kits are available for all types and models of lasers.We also offer a design service for custom installations. See accessories section.

Replacement Filters Replacement Parts

Labyrinth PVC Pre-FilterDescription: Code:F8/F9 Composite 111099

PCB (All models)Code:400001

Chemical Absorbent PadDescription: Code:PVC Pad (Pack of 4) 200281

Main Filters (All models)Description: Code:HEPA/PVC Chemical 110616

BlowerDescription: Code:(230V) 1500i PVC 300603/T(120V) 1500i PVC# 300603/T(400V) 2000i PVC 300612/T(220V) 2000i PVC 300612/T

FMU (All models)Description: Code:Filter Monitor Unit 400440

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.The display also shows which filter may need attention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Laser Interface Kit: (Optional)Extraction unit starts/stops when the laser is switchedON/OFF. Alerts are signalled to the laser. A timer makesthe extractor briefly run on after the laser is switched off toensure all fume is removed.Code: 100269

#These blowers operatethrough a factory fittedtransformer in 120Vmachines.

- 25 -

Laserex 4000 & 5000 PVC L a s e r f u m e e x t r a c t i o n s y s t e m

Laserex 4000 PVC Laserex 5000 PVCDescription: Code:400V 0PV4400D220V 0PV4401D

Filters / PCB specified on application. Filters / PCB specified on application.

Description: Code:400V 0PV5500D220V 0PV5501D

SpecificationUnit Laserex 4000 PVC Laserex 5000 PVCVoltage 400V 3ph + N 220V 3ph 400V 3ph + N 220V 3phPart number 0PV4400D 0PV4401D 0PV5500D 0PV5501DWattage 5.5 kW 5.5 kW 7.5 kW 7.5 kWSound rating 59 dBA 59 dBA 59 dBA 59 dBAMax flowrate 4000 m3/hr 2400 cf/m 5000 m3/hr 2940 cf/mFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 1810 mm 1810 mm 1810 mm 1810 mmCabinet width (not inc hose) 1210 mm 1210 mm 1210 mm 1210 mmCabinet depth (not inc hose) 885 mm 885 mm 885 mm 885 mmCabinet weight (inc filters) 340 Kg 340 Kg 340 Kg 340 KgHose (recommended) 150/200 mm 150/200 mm 150/200 mm 150/200 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Connection kits are available for all types and models of lasers.We also offer a design service for custom installations. See accessories section.

Replacement Filters Replacement PartsPCB (All models)Code:400000400001

BlowerDescription: Code:(400V) 4000 PVC 300614/T(220V) 4000 PVC 300614/T(400V) 5000 PVC 300615/T(220V) 5000 PVC 300615/T

FMU (All models)Description: Code:Filter Monitor Unit 400440

Custom Connection Kit

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.The display also shows which filter may need attention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Laser Interface Kit: (Optional)Extraction unit starts/stops when the laser is switchedON/OFF. Alerts are signalled to the laser. A timer makesthe extractor briefly run on after the laser is switched off toensure all fume is removed.Code: 100269

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

Pleated Bag Filter & Pre-Filter PadDescription: Code:Pre-filter Pad (Pack of 4) 200310Pleated Bag Filter 111154

Main FiltersDescription: Code:HEPA (std) 110633Chemical (std) 110627

Chemical Absorbent PadDescription: Code:PVC Pad (Pack of 4) 200312

- 26 -UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

Xbase™ for Engravers L a s e r f u m e e x t r a c t i o n s y s t e m

Xbase™ 200 Xbase™ 400Description Code:230V 0AL2106120V 0AL2107

Supplied with:1 x Main filter1 x Labyrinth pre-filter

Supplied with:1 x Main filter1 x Labyrinth pre-filter

Description Code:230V 0AL4104120V 0AL4107

Upgrade Pack-1Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomesblocked, the closed loop flow control systemautomatically adjusts the speed of the motor tomaintain a constant airflow throughout the life ofthe filter making the filter last longer.

Code: 100276Increase filter lifeand gain precise

control.

Interface with thelaser for greater

flexibility.

Upgrade Pack-2ON/OFF Control:Extraction unit starts/stops when the laser isswitched ON/OFF.

Filter Blocked Warning:A signal is sent to the laser to trigger a laser alertor to shut the laser down.Code: 100269

LASEREXD I G I T A L

LASEREXa l p h a

LA

SE

R

FUME EXTRACTION SYSTEMSPUREX

Replacement Filters Replacement Parts

Labyrinth Pre-Filter (All models)Description: Code:F8/F9 Composite 111108

PCB (All models)Code:400048

BlowerDescription: Code:230V Xbase 200 300170/T120V Xbase 200 300174/T230V Xbase 400 300172/T120V Xbase 400 300173/T

NB: Previous 120V machines used the 230V blowers above witha factory fitted transformer. Check the serial number of yourmachine with Purex prior to order of replacements.

Optional Connection Kit1 x Reducer 80-51mm1 x 3m of 51mm flexible hose (black)2 x 51mm cuffs (black)

Code:100032

Custom Connection Kits

Other connection kits are available for all typesand models of lasers. We also offer a design

service for custom installations.

Laser

SpecificationUnit Xbase 200 Xbase 400Voltage 230V ±10% 120V ±10% 230V ±10% 120V ±10%Part number 0AL2106 0AL2107 0AL4104 0AL4107Wattage 0.14 kW 0.14 kW 0.204 kW 0.255 kWSound rating 45 dBA 45 dBA 45 dBA 45 dBAMax flowrate 200 m3/hr 125 cf/m 400 m3/hr 235 cf/mFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 705 mm 705 mm 705 mm 705 mmCabinet width (not inc hose) 700 mm 700 mm 700 mm 700 mmCabinet depth (not inc hose) 640 mm 640 mm 640 mm 640 mmCabinet weight (inc filters) 63.5 Kg 63.5 Kg 63.5 Kg 63.5 KgHose (recommended) 51 mm 51 mm 51 mm 51 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Main Filters (All models)Description: Code:HEPA/Chemical (std) 110545HEPA/CSA (Acrylic) 113585

PPoowweerrffllooww™™FFuummee EExxttrraaccttiioonn aanndd

FFii llttrraattiioonn SSyysstteemmss

FUME EXTRACTION SYSTEMSPUREX

- 28 -

Powerflow 210 & 210i F u m e e x t r a c t i o n f o r m a c h i n e s

Powerflow 210 Powerflow 210iDescription: Code:230V 080210D120V 081210D

Supplied with:1 x Main filter1 x Pre-filter pad1 x Connection Kit (120262)

Supplied with:1 x Main filter1 x Labyrinth pre-filter1 x Connection Kit (120262)

Description: Code:230V 080210ID120V 081210ID

Replacement Filters Replacement PartsLabyrinth Pre-Filter (210i only)Description: Code:F6 (std) 111057F8/F9 Composite 111097

PCB (All models)Code:400001

Pre-Filter Pad (210 only)Description: Code:Pack of 4 202260

Main Filters (All models)Description: Code:HEPA/Chemical (std) 113505Chemical 113508HEPA/Chemical Cleanroom 113512

BlowerDescription: Code:(230V) 300593/T(120V) 300592/T

FMU (All models)Description: Code:Filter Monitor Unit 400440

Includes Standard Connection Kit1 x 80mm female coupling1 x 2m of 82mm flexible hose (black)2 x 70-90mm hose clips

Code:120262

Custom Connection Kits

Other connection kits are available for all types and models of associatedmachinery. We also offer a design service for custom installations.

SpecificationUnit Powerflow 210 Powerflow 210iVoltage 230V ±10% 120V ±10% 230V ±10% 120V ±10%Part number 080210D 081210D 080210iD 081210iDWattage 0.45 kW 0.45 kW 0.45 kW 0.45 kWSound rating 52 dBA 55 dBA 52 dBA 55 dBAMax flowrate 210 m3/hr 140 cf/m 210 m3/hr 140 cf/mFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 720 mm 720 mm 1070 mm 1070 mmCabinet width (not inc hose) 455 mm 455 mm 455 mm 455 mmCabinet depth (not inc hose) 480 mm 480 mm 480 mm 480 mmCabinet weight (inc filters) 47 Kg 47 Kg 55 Kg 55 KgHose (recommended) 82 mm 82 mm 82 mm 82 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.The display also shows which filter may need attention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Interface Kit: (Optional)Extraction unit starts/stops when associated machinery isswitched ON/OFF. Alerts are signalled to the associatedmachinery. A timer makes the extractor briefly run onafter associated machinery is switched off to ensure allfume is removed.Code: 100269

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 29 -

Includes Standard Connection Kit1 x 80mm female coupling1 x 2m of 82mm flexible hose (black)2 x 70-90mm hose clips

Code:120262

Custom Connection Kits

Other connection kits are available for all types and models of associatedmachinery. We also offer a design service for custom installations.

Powerflow 400 & 400i F u m e e x t r a c t i o n f o r m a c h i n e s

Powerflow 400 Powerflow 400iDescription: Code:230V 080400D120V 081400D

Supplied with:1 x Main filter1 x Pre-filter pad1 x Connection Kit (120262)

Supplied with:1 x Main filter1 x Labyrinth pre-filter1 x Connection Kit (120262)

Description: Code:230V 080400ID120V 081400ID

Replacement Filters Replacement PartsLabyrinth Pre-Filter (400i only)Description: Code:F6 (std) 111057F8/F9 Composite 111097

PCB (All models)Code:400001

Pre-Filter Pad (400 only)Description: Code:Pack of 4 202260

Main Filters (All models)Description: Code:HEPA/Chemical (std) 113505Chemical 113508HEPA/Chemical Cleanroom 113512

BlowerDescription: Code:(230V) 300595/T(120V) 300594/T

FMU (All models)Description: Code:Filter Monitor Unit 400440

SpecificationUnit Powerflow 400 Powerflow 400iVoltage 230V ±10% 120V ±10% 230V ±10% 120V ±10%Part number 080400D 081400D 080400iD 081400iDWattage 1.2 kW 1.1 kW 1.2 kW 1.1 kWSound rating 52 dBA 55 dBA 52 dBA 55 dBAMax flowrate 460 m3/hr 270 cf/m 460 m3/hr 270 cf/mFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 720 mm 720 mm 1070 mm 1070 mmCabinet width (not inc hose) 455 mm 455 mm 455 mm 455 mmCabinet depth (not inc hose) 480 mm 480 mm 480 mm 480 mmCabinet weight (inc filters) 47 Kg 47 Kg 55 Kg 55 KgHose (recommended) 82 mm 82 mm 82 mm 82 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.The display also shows which filter may need attention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Interface Kit: (Optional)Extraction unit starts/stops when associated machinery isswitched ON/OFF. Alerts are signalled to the associatedmachinery. A timer makes the extractor briefly run onafter associated machinery is switched off to ensure allfume is removed.Code: 100269

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 30 -

Powerflow 800i F u m e e x t r a c t i o n f o r m a c h i n e s

Powerflow 800i (2-Tier) Powerflow 800i (3-Tier)Description: Code:230V 080509D120V 080511D

Supplied with:1 x Main filter1 x Labyrinth pre-filter

Supplied with:2 x Main filters1 x Labyrinth pre-filter

Description: Code:230V 080508D120V 080510D

Replacement Filters Replacement PartsLabyrinth Pre-FilterDescription: Code:F6 (2-Tier std) 111098F8/9 Composite (2-Tier) 111004F8/9 Composite (3-Tier std) 111101

PCB (All models)Code:400001

Main FiltersDescription: Code:(2-Tier)HEPA/Chemical (std) 113652HEPA/Twin Chemical 113660(3-Tier)HEPA (std) 113650Chemical (std) 113651

Blower (800i machines have 2 blowers)Description: Code:(230V) 300595/T(120V) 300594/T

FMU (All models)Description: Code:Filter Monitor Unit 400440

SpecificationUnit Powerflow 800i (2-Tier) Powerflow 800i (3-Tier)Voltage 230V ±10% 120V ±10% 230V ±10% 120V ±10%Part number 080509D 080511D 080508D 080510DWattage 2.4 kW 2.2 kW 2.4 kW 2.2 kWSound rating 65 dBA 65 dBA 65 dBA 65 dBAMax flowrate 800 m3/hr 471 cf/m 800 m3/hr 471 cf/mFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 1150 mm 1150 mm 1150 mm 1150 mmCabinet width (not inc hose) 540 mm 540 mm 540 mm 540 mmCabinet depth (not inc hose) 670 mm 670 mm 670 mm 670 mmCabinet weight (inc filters) 80 Kg 80 Kg 80 Kg 80 KgHose (recommended) 100 mm 100 mm 100 mm 100 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Custom Connection Kit

Connection kits are available for all types and models of associated machinery and applications.We also offer a design service for custom installations. See accessories section.

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.The display also shows which filter may need attention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Interface Kit: (Optional)Extraction unit starts/stops when associated machinery isswitched ON/OFF. Alerts are signalled to the associatedmachinery. A timer makes the extractor briefly run onafter associated machinery is switched off to ensure allfume is removed.Code: 100269

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 31 -

Powerflow 1500 & 1500i F u m e e x t r a c t i o n f o r m a c h i n e s

Powerflow 1500 Powerflow 1500iDescription: Code:230V 021510D120V 021501D

Supplied with:1 x Main filter1 x Pre-filter pad

Supplied with:1 x Main filter1 x Labyrinth pre-filter

Description: Code:230V 021510ID120V 021501ID

Replacement Filters Replacement PartsLabyrinth Pre-Filter (1500i only)Description: Code:F6 (std) 111037F8/9 Composite 111099

PCB (All models)Code:400001

Pre-Filter Pad (1500 only)Description: Code:Pack of 4 200280

Main Filters (All models)Description: Code:HEPA/Chemical (std) 110615Chemical 110610HEPA/Chemical Cleanroom 110632Castellated Carbon 110620

BlowerDescription: Code:(230V / 120V) 300603/TThese blowers operate through a factory fittedtransformer in 120V machines.

FMU (All models)Description: Code:Filter Monitor Unit 400440

SpecificationUnit Powerflow 1500 Powerflow 1500iVoltage 230V ±10% 120V ±10% 230V ±10% 120V ±10%Part number 021510D 021501D 021510iD 021501iDWattage 1.5 kW 1.5 kW 1.5 kW 1.5 kWSound rating 59 dBA 59 dBA 59 dBA 59 dBAMax flowrate 1700 m3/hr 700 cf/m 1700 m3/hr 700 cf/mFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 1100 mm 1100 mm 1400 mm 1400 mmCabinet width (not inc hose) 690 mm 690 mm 690 mm 690 mmCabinet depth (not inc hose) 710 mm 710 mm 710 mm 710 mmCabinet weight (inc filters) 112 Kg 112 Kg 134 Kg 134 KgHose (recommended) 150 mm 150 mm 150 mm 150 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Custom Connection Kit

Other connection kits are available for all types and models of associated machinery.We also offer a design service for custom installations.

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.The display also shows which filter may need attention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Interface Kit: (Optional)Extraction unit starts/stops when associated machinery isswitched ON/OFF. Alerts are signalled to the associatedmachinery. A timer makes the extractor briefly run onafter associated machinery is switched off to ensure allfume is removed.Code: 100269

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 32 -

Powerflow 2000 & 2000i F u m e e x t r a c t i o n f o r m a c h i n e s

Powerflow 2000 Powerflow 2000iDescription: Code:400V 022010D220V 022011D

Supplied with:1 x Main filter1 x Pre-filter pad

Supplied with:1 x Main filter1 x Labyrinth pre-filter

Description: Code:400V 022010ID220V 022011ID

Replacement Parts

PCB (All models)Code:400001

BlowerDescription: Code:(220V / 400V) 300612/T

FMU (All models)Description: Code:Filter Monitor Unit 400440

SpecificationUnit Powerflow 2000 Powerflow 2000iVoltage 400V 3ph + N 220V 3ph 400V 3ph + N 220V 3phPart number 022010D 022011D 022010iD 022011iDWattage 3.0 kW 3.0 kW 3.0 kW 3.0 kWSound rating 59 dBA 59 dBA 59 dBA 59 dBAMax flowrate 2200 m3/hr 1300 cf/m 2200 m3/hr 1300 cf/mFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 1100 mm 1100 mm 1400 mm 1400 mmCabinet width (not inc hose) 690 mm 690 mm 690 mm 690 mmCabinet depth (not inc hose) 710 mm 710 mm 710 mm 710 mmCabinet weight (inc filters) 112 Kg 112 Kg 148 Kg 148 KgHose (recommended) 150 mm 150 mm 150 mm 150 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Custom Connection Kit

Connection kits are available for all types and models of associated machinery and applications.We also offer a design service for custom installations. See accessories section.

Replacement FiltersLabyrinth Pre-Filter (2000i only)Description: Code:F6 (std) 111037F8/9 Composite 111099

Pre-Filter Pad (2000 only)Description: Code:Pack of 4 200280

Main Filters (All models)Description: Code:HEPA/Chemical (std) 110615Chemical 110610HEPA/Chemical Cleanroom 110632Castellated Carbon 110620

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.The display also shows which filter may need attention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Interface Kit: (Optional)Extraction unit starts/stops when associated machinery isswitched ON/OFF. Alerts are signalled to the associatedmachinery. A timer makes the extractor briefly run onafter associated machinery is switched off to ensure allfume is removed.Code: 100269

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 33 -

Custom Connection Kit

Connection kits are available for all types and models of associated machinery and applications.We also offer a design service for custom installations. See accessories section.

Powerflow 4000 & 5000 F u m e e x t r a c t i o n f o r m a c h i n e s

Powerflow 4000 Powerflow 5000Description: Code:400V 044010D220V 044011D

Supplied with:2 x Main filters and1 x Labyrinth pre-filteror 1 x Pleated bag filter with 5 x pre-filter pads* Specify filter combinations and PCB type onordering

Supplied with:2 x Main filters and1 x Labyrinth pre-filteror 1 x Pleated bag filter with 5 x pre-filter pads* Specify filter combinations and PCB type onordering

Description: Code:400V 055010D220V 055011D

Replacement Filters Replacement Parts(Option-1) Labyrinth Pre-FilterDescription: Code:F8 (std) 111072F8/F9 Composite 111006

PCB (All models)Code:400000or 400001

(Option-2) Pleated Bag Filter & Pre-Filter Pad(std)Description: Code:Pre-filter Pad (Pack of 4) 200310Pleated Bag Filter 111144

Main FiltersDescription: Code:HEPA (std) 110633Chemical (std) 110627

BlowerDescription: Code:400V Powerflow 4000 300614/T220V Powerflow 4000 300614/T400V Powerflow 5000 300615/T220V Powerflow 5000 300615/T

FMU (All models)Description: Code:Filter Monitor Unit 400440

SpecificationUnit Powerflow 4000 Powerflow 5000Voltage 400V 3ph + N 220V 3ph 400V 3ph + N 220V 3phPart number 044010D 044011D 055010D 055011DWattage 5.5 kW 5.5 kW 7.5 kW 7.5 kWSound rating 59 dBA 59 dBA 59 dBA 59 dBAMax flowrate 4000 m3/hr 2400 cf/m 5000 m3/hr 2940 cf/mFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 1810 mm 1810 mm 1810 mm 1810 mmCabinet width (not inc hose) 1210 mm 1210 mm 1210 mm 1210 mmCabinet depth (not inc hose) 885 mm 885 mm 885 mm 885 mmCabinet weight (inc filters) 340 Kg 340 Kg 340 Kg 340 KgHose (recommended) 150/200 mm 150/200 mm 150/200 mm 150/200 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.The display also shows which filter may need attention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Interface Kit: (Optional)Extraction unit starts/stops when associated machinery isswitched ON/OFF. Alerts are signalled to the associatedmachinery. A timer makes the extractor briefly run onafter associated machinery is switched off to ensure allfume is removed.Code: 100269

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 34 -

Notes

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

SSuuppeerrffllooww™™AArrmm EExxttrraaccttiioonn

AArrmm EExxttrraaccttiioonn aannddFFii llttrraattiioonn SSyysstteemmssFUME EXTRACTION SYSTEMS

PUREX

- 36 -

Superflow 2-6 Arm A r m e x t r a c t i o n s y s t e m

Superflow 2-6 Arm (Standard) Superflow 2-6 Arm (Integral)Description: Code:230V 080026D120V 081026D

Supplied with:1 x Main filter1 x Pre-filter pad1 x Connection Kit (120262)

Other connection kits are available. Other connection kits are available.

Supplied with:1 x Main filter1 x Labyrinth pre-filter1 x Connection Kit (120262)

Description: Code:230V 080026ID120V 081026ID

Replacement Filters Replacement PartsLabyrinth Pre-Filter (Integral only)Description: Code:F6 (std) 111057F8/F9 Composite 111097

PCB (All models)Code:400000

Pre-Filter Pad (Standard only)Description: Code:Pack of 4 202260

Main Filters (All models)Description: Code:HEPA/Chemical (std) 113505Chemical 113508HEPA/Chemical Cleanroom 113512

BlowerDescription: Code:(230V) 300593/T(120V) 300592/T

FMU (All models)Description: Code:Filter Monitor Unit 400440

Includes Standard Connection Kit1 x 80mm female coupling1 x 1.2m of 82mm flexible hose (black)2 x 70-90mm hose clipsOther connection kits are available.Code:120262

Maximum StationsStation Type Max No.25mm Arms 632mm Arms 438mm Arms 354mm Arms 2

Station Type Max No.Cleancabs™ 2Plenum Cowls 2100mm Arms -

SpecificationUnit 2-6 Arm (Standard) 2-6 Arm (Integral)Voltage 230V ±10% 120V ±10% 230V ±10% 120V ±10%Part number 080026D 081026D 080026iD 081026iDWattage 0.45 kW 0.45 kW 0.45 kW 0.45 kWSound rating 52 dBA 55 dBA 52 dBA 55 dBAFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 720 mm 720 mm 1070 mm 1070 mmCabinet width (not inc hose) 455 mm 455 mm 455 mm 455 mmCabinet depth (not inc hose) 480 mm 480 mm 480 mm 480 mmCabinet weight (inc filters) 47 Kg 47 Kg 55 Kg 55 KgHose (recommended) 82 mm 82 mm 82 mm 82 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.The display also shows which filter may need attention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Interface Kit: (Optional)Extraction unit starts/stops when associated machinery isswitched ON/OFF. Alerts are signalled to the associatedmachinery. A timer makes the extractor briefly run onafter associated machinery is switched off to ensure allfume is removed.Code: 100269

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 37 -

Superflow 4-10 Arm A r m e x t r a c t i o n s y s t e m

Superflow 4-10 Arm (Standard) Superflow 4-10 Arm (Integral)Description: Code:230V 080410D120V 080411D

Supplied with:1 x Main filter1 x Pre-filter pad1 x Connection Kit (120262)

Other connection kits are available. Other connection kits are available.

Supplied with:1 x Main filter1 x Labyrinth pre-filter1 x Connection Kit (120262)

Description: Code:230V 080410ID120V 080411ID

Replacement Filters Replacement PartsLabyrinth Pre-Filter (Integral only)Description: Code:F6 (std) 111057F8/F9 Composite 111097

PCB (All models)Code:400000

Pre-Filter Pad (Standard only)Description: Code:Pack of 4 202260

Main Filters (All models)Description: Code:HEPA/Chemical (std) 113505Chemical 113508HEPA/Chemical Cleanroom 113512

BlowerDescription: Code:(230V) 300595/T(120V) 300594/T

FMU (All models)Description: Code:Filter Monitor Unit 400440

SpecificationUnit 4-10 Arm (Standard) 4-10 Arm (Integral)Voltage 230V ±10% 120V ±10% 230V ±10% 120V ±10%Part number 080410D 080411iD 080410iD 080411iDWattage 1.2 kW 1.1 kW 1.2 kW 1.1 kWSound rating 52 dBA 52 dBA 52 dBA 52 dBAFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 720 mm 1070 mm 1070 mm 1070 mmCabinet width (not inc hose) 455 mm 455 mm 455 mm 455 mmCabinet depth (not inc hose) 480 mm 480 mm 480 mm 480 mmCabinet weight (inc filters) 47 Kg 55 Kg 55 Kg 55 KgHose (recommended) 82 mm 82 mm 82 mm 82 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Includes Standard Connection Kit1 x 80mm female coupling1 x 1.2m of 82mm flexible hose (black)2 x 70-90mm hose clipsOther connection kits are available.Code:120262

Maximum StationsStation Type Max No.25mm Arms 1032mm Arms 838mm Arms 654mm Arms 4

Station Type Max No.Cleancabs™ 4Plenum Cowls 4100mm Arms 1

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.The display also shows which filter may need attention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Interface Kit: (Optional)Extraction unit starts/stops when associated machinery isswitched ON/OFF. Alerts are signalled to the associatedmachinery. A timer makes the extractor briefly run onafter associated machinery is switched off to ensure allfume is removed.Code: 100269

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 38 -

Superflow 6-15 Arm A r m e x t r a c t i o n s y s t e m

Superflow 6-15 Arm (2-Tier) Superflow 6-15 Arm (3-Tier)Description: Code:230V 080505D120V 080507D

Supplied with:1 x Main filter1 x Labyrinth pre-filter

Connection kits are available. Connection kits are available.

Supplied with:2 x Main filters1 x Labyrinth pre-filter

Description: Code:230V 080504D120V 080506D

Replacement Filters Replacement PartsLabyrinth Pre-FilterDescription: Code:F6 (2-Tier std) 111098F8/9 Composite (2-Tier) 111004F8/9 Composite (3-Tier std) 111101

PCB (All models)Code:400000

Main FiltersDescription: Code:(2-Tier)HEPA/Chemical (std) 113652HEPA/Twin Chemical 113660(3-Tier)HEPA (std) 113650Chemical (std) 113651

Blower (800i machines have 2 blowers)Description: Code:(230V) 300595/T(120V) 300594/T

FMU (All models)Description: Code:Filter Monitor Unit 400440

SpecificationUnit 6-15 Arm (2-Tier) 6-15 Arm (3-Tier)Voltage 230V ±10% 120V ±10% 230V ±10% 120V ±10%Part number 080505D 080507D 080504D 080506DWattage 2.4 kW 2.2 kW 2.4 kW 2.2 kWSound rating 65 dBA 65 dBA 65 dBA 65 dBAFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 1150 mm 1150 mm 1150 mm 1150 mmCabinet width (not inc hose) 540 mm 540 mm 540 mm 540 mmCabinet depth (not inc hose) 670 mm 670 mm 670 mm 670 mmCabinet weight (inc filters) 80 Kg 80 Kg 80 Kg 80 KgHose (recommended) 100 mm 100 mm 100 mm 100 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Custom Connection Kits

Connection kits are available for all types and models of associatedmachinery and applications. We also offer a design service for custom

installations.

Maximum StationsStation Type Max No.25mm Arms 1532mm Arms 1238mm Arms 954mm Arms 6

Station Type Max No.Cleancabs™ 6Plenum Cowls 6100mm Arms 2

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.The display also shows which filter may need attention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Interface Kit: (Optional)Extraction unit starts/stops when associated machinery isswitched ON/OFF. Alerts are signalled to the associatedmachinery. A timer makes the extractor briefly run onafter associated machinery is switched off to ensure allfume is removed.Code: 100269

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 39 -

Superflow 8-20 Arm A r m e x t r a c t i o n s y s t e m

Superflow 8-20 Arm (Standard) Superflow 8-20 Arm (Integral)Description: Code:230V 021820D

Supplied with:1 x Main filter1 x Pre-filter pad

Supplied with:1 x Main filter1 x Labyrinth pre-filter

Description: Code:230V 021820ID

Replacement Filters Replacement PartsLabyrinth Pre-Filter (Integral only)Description: Code:F6 (std) 111037F8/9 Composite 111099

PCB (All models)Code:400000

Pre-Filter Pad (Standard only)Description: Code:Pack of 4 200280

Main Filters (All models)Description: Code:HEPA/Chemical (std) 110615Chemical 110610HEPA/Chemical Cleanroom 110632Castellated Carbon 110620

BlowerDescription: Code:(230V) 300603/T

FMU (All models)Description: Code:Filter Monitor Unit 400440

SpecificationUnit Superflow 8-20 Arm (Standard) Superflow 8-20 Arm (Integral)Voltage 230V ±10% 230V ±10%Part number 021820D 021820iDWattage 1.5 kW 1.5 kWSound rating 59 dBA 59 dBAFrequency 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 1100 mm 1400 mmCabinet width (not inc hose) 690 mm 690 mmCabinet depth (not inc hose) 710 mm 710 mmCabinet weight (inc filters) 112 Kg 134 KgHose (recommended) 150 mm 150 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Custom Connection Kits

Other connection kits are available for all types and models of associatedmachinery. We also offer a design service for custom installations.

Maximum StationsStation Type Max No.25mm Arms 2032mm Arms 1638mm Arms 1254mm Arms 8

Station Type Max No.Cleancabs™ 8Plenum Cowls 8100mm Arms 4

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.The display also shows which filter may need attention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Interface Kit: (Optional)Extraction unit starts/stops when associated machinery isswitched ON/OFF. Alerts are signalled to the associatedmachinery. A timer makes the extractor briefly run onafter associated machinery is switched off to ensure allfume is removed.Code: 100269

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 40 -

Superflow 10-25 Arm A r m e x t r a c t i o n s y s t e m

Superflow 10-25 Arm (Standard) Superflow 10-25 Arm (Integral)Description: Code:400V 022120D220V 022121D

Supplied with:1 x Main filter1 x Pre-filter pad

Supplied with:1 x Main filter1 x Labyrinth pre-filter

Description: Code:400V 022120ID220V 022121ID

Replacement Parts

PCB (All models)Code:400000

BlowerDescription: Code:(220V / 400V) 300612/T

FMU (All models)Description: Code:Filter Monitor Unit 400440

SpecificationUnit Superflow 10-25 Arm (Standard) Superflow 10-25 Arm (Integral)Voltage 400V 3ph + N 220V 3ph 400V 3ph + N 220V 3phPart number 022120D 022121D 022120iD 022121iDWattage 3.0 kW 3.0 kW 3.0 kW 3.0 kWSound rating 59 dBA 59 dBA 59 dBA 59 dBAFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 1100 mm 1100 mm 1400 mm 1400 mmCabinet width (not inc hose) 690 mm 690 mm 690 mm 690 mmCabinet depth (not inc hose) 710 mm 710 mm 710 mm 710 mmCabinet weight (inc filters) 112 Kg 112 Kg 148 Kg 148 KgHose (recommended) 150 mm 150 mm 150 mm 150 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Replacement FiltersLabyrinth Pre-Filter (Integral only)Description: Code:F6 (std) 111037F8/F9 Composite 111099

Pre-Filter Pad (Standard only)Description: Code:Pack of 4 200280

Main Filters (All models)Description: Code:HEPA/Chemical (std) 110615Chemical 110610HEPA/Chemical Cleanroom 110632Castellated Carbon 110620

Custom Connection Kits

Other connection kits are available for all types and models of associatedmachinery. We also offer a design service for custom installations.

Maximum StationsStation Type Max No.25mm Arms 2532mm Arms 2038mm Arms 1554mm Arms 10

Station Type Max No.Cleancabs™ 10Plenum Cowls 10100mm Arms 5

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.The display also shows which filter may need attention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Interface Kit: (Optional)Extraction unit starts/stops when associated machinery isswitched ON/OFF. Alerts are signalled to the associatedmachinery. A timer makes the extractor briefly run onafter associated machinery is switched off to ensure allfume is removed.Code: 100269

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 41 -

Superflow 20-50 Arm A r m e x t r a c t i o n s y s t e m

Supplied with:2 x Main filters and1 x Labyrinth pre-filteror 1 x Pleated bag filter with 5 x pre-filter pads* Specify filter combinations on ordering

Description: Code:400V 044250D220V 044251D

Replacement Filters Replacement Parts(Option-1) Labyrinth Pre-FilterDescription: Code:F8 111072F8/F9 Composite 111006

PCB (All models)Code:400000

(Option-2) Pleated Bag Filter & Pre-Filter Pad(std)Description: Code:Pre-filter Pad (Pack of 4) 200310Pleated Bag Filter 111144

Main FiltersDescription: Code:HEPA (std) 110633Chemical (std) 110627

BlowerDescription: Code:400V 4000 300614/T220V 4000 300614/T

FMU (All models)Description: Code:Filter Monitor Unit 400440

SpecificationUnit Superflow 20-50 ArmVoltage 400V 3ph + N 220V 3phPart number 044250D 044251DWattage 5.5 kW 5.5 kWSound rating 59 dBA 59 dBAFrequency 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 1810 mm 1810 mmCabinet width (not inc hose) 1210 mm 1210 mmCabinet depth (not inc hose) 885 mm 885 mmCabinet weight (inc filters) 340 Kg 340 KgHose (recommended) 150/200 mm 150/200 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Custom Connection Kits

Other connection kits are available for all types and models of associatedmachinery. We also offer a design service for custom installations.

Maximum StationsStation Type Max No.25mm Arms 5032mm Arms 4038mm Arms 3054mm Arms 20

Station Type Max No.Cleancabs™ 20Plenum Cowls 20100mm Arms 9

Superflow 20-50 Arm

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.The display also shows which filter may need attention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Interface Kit: (Optional)Extraction unit starts/stops when associated machinery isswitched ON/OFF. Alerts are signalled to the associatedmachinery. A timer makes the extractor briefly run onafter associated machinery is switched off to ensure allfume is removed.Code: 100269

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 42 -

Notes

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

Superflow™Tip Extraction

Soldering Iron Tip Extraction andFiltration SystemsFUME EXTRACTION SYSTEMS

PUREX

- 44 -

Superflow Tip Systems Solder ing i ron t ip ext ract ion system

Addtional pipework and connectionsrequired depending on theinstallation and number of solderingstations. See pipework section.

Supplied with:1 x Main filter1 x Pre-filter pad1 x Connection Kit (100170)

Description: Code:20 Tip System (Connects up to 20 soldering irons)230V 080020D120V 081020D30 Tip System (Connects up to 30 soldering irons)230V 080030D120V 081030D50 Tip System (Connects up to 50 soldering irons)230V 080050D

Replacement Filters Replacement Parts

PCB (All models)Code:400000Pre-Filter Pad (All models)

Description: Code:Pack of 4 202260

Main Filters (All models)Description: Code:HEPA/Chemical (std) 113505Chemical 113508

BlowerDescription: Code:20+30 Tip (230V) 300593/T20+30 Tip (120V) 300592/T50 Tip (230V) 300596/T

FMU (All models)Description: Code:Filter Monitor Unit 400440

Includes Standard Connection Kit1 x 80mm female coupling1 x 1.2m of 82mm flexible hose (black)2 x 70-90mm hose clips

Code:100170

Station Design

Soldering Irons are connected to the extraction system via flexible, burnproof silicone tube. A variety of connections and ON/OFF taps areavailable. See pipework section.

SpecificationUnit Superflow 20 Tip Superflow 30 Tip Superflow 50 TipVoltage 230V ±10% 120V ±10% 230V ±10% 120V ±10% 230V ±10%Part number 080020D 081020D 080030D 081030D 080050DWattage 0.45 kW 0.45 kW 0.45 kW 0.45 kW 1.1 kWSound rating 52 dBA 55 dBA 52 dBA 55 dBA 52 dBAMax stations 20 at 30 l/min 20 at 30 l/min 30 at 30 l/min 30 at 30 l/min 50 at 30 l/minFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 720 mm 720 mm 720 mm 720 mm 720 mmCabinet width (not inc hose) 455 mm 455 mm 455 mm 455 mm 455 mmCabinet depth (not inc hose) 480 mm 480 mm 480 mm 480 mm 480 mmCabinet weight (inc filters) 47 Kg 47 Kg 47 Kg 47 Kg 47 KgHose (recommended) 32 mm 32 mm 50 mm 50 mm 50 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Superflow Tip Extraction Systems (Centralised system for up to 50 users)

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.The display also shows which filter may need attention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Interface Kit: (Optional)Extraction unit starts/stops when associated machinery isswitched ON/OFF. Alerts are signalled to the associatedmachinery. A timer makes the extractor briefly run onafter associated machinery is switched off to ensure allfume is removed.Code: 100269

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

Superflow Integral Tip Systems Solder ing i ron t ip ext ract ion system

Addtional pipework and connectionsrequired depending on theinstallation and number of solderingstations. See pipework section.

Supplied with:1 x Main filter1 x Pre-filter pad1 x Connection Kit (100170)

Description: Code:20 Tip System (Connects up to 20 soldering irons)230V 080020ID120V 081020ID30 Tip System (Connects up to 30 soldering irons)230V 080030ID120V 081030ID50 Tip System (Connects up to 50 soldering irons)230V 080050ID

Replacement Filters Replacement Parts

PCB (All models)Code:400000

Labyrinth Pre-Filter (Integral only)Description: Code:F6 (std) 111057F8/F9 Composite 111097

Main Filters (All models)Description: Code:HEPA/Chemical (std) 113505Chemical 113508

BlowerDescription: Code:20+30 Tip (230V) 300593/T20+30 Tip (120V) 300592/T50 Tip (230V) 300596/T

FMU (All models)Description: Code:Filter Monitor Unit 400440

Includes Standard Connection Kit1 x 80mm female coupling1 x 1.2m of 82mm flexible hose (black)2 x 70-90mm hose clips

Code:100170

Station Design

Soldering Irons are connected to the extraction system via flexible, burnproof silicone tube. A variety of connections and ON/OFF taps areavailable. See pipework section.

SpecificationUnit Superflow 20 Tip Integral Superflow 30 Tip Integral Superflow 50 Tip (Int)Voltage 230V ±10% 120V ±10% 230V ±10% 120V ±10% 230V ±10%Part number 080020iD 081020iD 080030iD 081030iD 080050iDWattage 0.45 kW 0.45 kW 0.45 kW 0.45 kW 1.1 kWSound rating 52 dBA 55 dBA 52 dBA 55 dBA 52 dBAMax stations 20 at 30 l/min 20 at 30 l/min 30 at 30 l/min 30 at 30 l/min 50 at 30 l/minFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 1070 mm 1070 mm 1070 mm 1070 mm 1070 mmCabinet width (not inc hose) 455 mm 455 mm 455 mm 455 mm 455 mmCabinet depth (not inc hose) 480 mm 480 mm 480 mm 480 mm 480 mmCabinet weight (inc filters) 55 Kg 55 Kg 55 Kg 55 Kg 55 KgHose (recommended) 32 mm 32 mm 50 mm 50 mm 50 mm

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Superflow Integral Tip Extraction Systems (Centralised system for up to 50 users)

Digital Control System with Graphic Display Supplied as StandardFilter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.The display also shows which filter may need attention.

Gas and Particle Sensors:An exhausted or incorrectly fitted filter may allow hazardousgas or particles to pass through the system. These sensorsconstantly monitor the exhaust and alert the operator if thisoccurs.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.22

0

0

°C

m3/ hr

Increase filter life andgain precise control.

Interface Kit: (Optional)Extraction unit starts/stops when associated machinery isswitched ON/OFF. Alerts are signalled to the associatedmachinery. A timer makes the extractor briefly run onafter associated machinery is switched off to ensure allfume is removed.Code: 100269

- 45 -UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 46 -

3-10 Tip System Solder ing i ron t ip ext ract ion system

Supplied with:1 x HEPA/Chemical Filter1 x Pre-Filter10 x 560mm x 32mm Ø pipework. Fitted with Adaptors and Blanking Plugs10 x Straight Connectors2 x 90º Elbow Joints1 x 1m x 32mm Ø flexible connection hose1 x Control Tap + Silencer3 x Standard Weller Iron Adaptor Kits. Alternative kits available on request3 x 5mm Cleaning Brushes

Description: Code:230V 070350120V 070351

More accessories are available.See pipework section.

Replacement Filters

Replacement Parts

BlowerDescription: Code:(230V) 300020/T(120V) 300030/T

Pre-Filter Pad (All models)Description: Code:Pack of 4 200225

Main Filters (All models)Description: Code:HEPA/Chemical 110507

AccessoriesMini Weller iron adaptor kit 1000651 x extraction tube clip 8300501 x 6mm Ø x 135mm extraction tube 8301121 x 1.5m x 5mm ID x 1.5mm wall clear silicone hose 5600104 x 8mm Ø hose clips 5805211 x soldering iron stand 8300081 x cup 8300051 x screw in adaptor (8mm hose, M10) 580010

Standard Weller/RS/Adcola iron adaptor kit 1000601 x extraction tube clip 8300401 x 6mm Ø x 100mm extraction tube 8301101 x 1.5m x 5mm ID x 1.5mm wall clear silicone hose 5600104 x 8mm Ø hose clips 5805211 x soldering iron stand 8300081 x cup 8300001 x screw in adaptor (8mm hose, M10) 580010

Large Weller iron adaptor kit 1000701 x extraction tube clip 8300411 x 7mm Ø x 150mm extraction tube 8301151 x 1.5m x 6mm ID x 1.5mm wall clear silicone hose 5600304 x 8mm Ø hose clips 5805211 x soldering iron stand 8300081 x cup 8300021 x screw in adaptor (8mm hose, M10) 580010

Pace iron adaptor kit 1000721 x extraction tube clip 8300651 x 6mm Ø x 100mm extraction tube 8301101 x 1.5m x 6mm ID x 1.5mm wall clear silicone hose 5600304 x 8mm Ø hose clips 5805211 x soldering iron stand 8300081 x cup 8300021 x screw in adaptor (8mm hose, M10) 580010

Metcal iron adaptor kit 1000751 x extraction tube clip 8300501 x 6mm Ø x 135mm extraction tube 8301121 x 1.5m x 5mm ID x 1.5mm wall clear silicone hose 5600104 x 8mm Ø hose clips 580521Universal iron stand 8300071 x screw in adaptor (8mm hose, M10) 580010

Antex iron adaptor kit 1000851 x extraction tube clip 8300501 x 6mm Ø x 225mm extraction tube 8301351 x 1.5m x 5mm ID x 1.5mm wall clear silicone hose 5600104 x 8mm Ø hose clips 580521Universal iron stand 8300071 x screw in adaptor (8mm hose, M10) 580010

Hakko iron adaptor kit 1000302 x extraction tube clip 8300501 x 6mm Ø x 225mm extraction tube 830136

Tube cleaning brushes5mm bronze 8302006mm bronze 8302108mm bronze 830220Iron standsUniversal iron stand 830007

Each kit contains the items shown underneath. For other types of soldering iron, please call for details.

SpecificationSYSTEM 3-10 StationVoltage 230V ±10% 120V ±10%Part number 070350 070351Wattage 0.2kW 0.25kWFrequency 50Hz 60HzSound rating 54dBA 54dBAMax stations 10 at 28 l/min 10 at 28 l/minCabinet height 450mm 450mmCabinet width 300mm 300mmCabinet depth 280mm 280mmCabinet weight (inc filters) 17Kg 17Kg

3-10 Tip System (Centralised system for up to 10 users)

Accessories

ExtractionTube Clip

ExtractionTube Clip

SiliconeHose

Hose Clips

Iron Stand

UniversalIron Stand

TubeCleaning

Brush

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

FFuummeeCCuubbee™™ &&FFuummeeBBuusstteerr™™

MMuullttii--ppuurrppoossee aarrmm eexxttrraaccttiioonnaanndd ffii llttrraattiioonn ssyysstteemmss..FUME EXTRACTION SYSTEMS

PUREX

- 48 -

FumeCube A r m e x t r a c t i o n s y s t e m

Single Arm Kit Dual Arm KitDescription: Code:230V (with pen nib) 072066120V (with pen nib) 072067

230V (conical cowl) 072105120V (conical cowl) 072107

Supplied with:1 x FumeCube1 x Filter + pre-filter pad1 x 51mm x 2m flexible hose [black]2 x Connecting cuffs [black]1 x Clamped bracket1 x 38mm stainless steel flexible arm and valve1 x 38mm pen nib nozzle or conical cowl.

Supplied with:1 x FumeCube1 x Filter + pre-filter pad2 x 51mm x 2m flexible hose [black]4 x Connecting cuffs [black]2 x Clamped bracket2 x 38mm stainless steel flexible arm and valve2 x 38mm pen nib nozzle or conical cowl.

Description: Code:230V (with pen nib) 072065120V (with pen nib) 072068

230V (conical cowl) 072104120V (conical cowl) 072106

Replacement Filters Replacement Parts

Pre-Filter Pad (All models)Description: Code:(For HEPA + Cleanroom main filters)Pack of 4 200225(For Chemical main filters)Pack of 4 200290

PCB (All models)Code:400048

Main FiltersDescription: Code:HEPA/Chemical (std) 110536Chemical 110537Cleanroom 110538

BlowerDescription: Code:230V 300170/T120V 300174/T

NB: Previous 120V machines used the 230V blowers above witha factory fitted transformer. Check the serial number of yourmachine with Purex prior to order of replacements.

SpecificationUnit FumeCube (Single Arm) FumeCube (Dual Arm)Voltage 230V ±10% 120V ±10% 230V ±10% 120V ±10%Part number 072066/072105 072067/072107 072065/072104 072068/072106Wattage 0.14 kW 0.14 kW 0.14 kW 0.14 kWSound rating 60 dBA 60 dBA 60 dBA 60 dBAFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzMax flowrate 200 m3/hr 125cf/m 200 m3/hr 125cf/mCabinet height 350 mm 350 mm 350 mm 350 mmCabinet width (not inc hose) 308 mm 308 mm 308 mm 308 mmCabinet depth (not inc hose) 283 mm 283 mm 283 mm 283 mmCabinet weight (inc filters) 12.5 Kg 12.5 Kg 12.5 Kg 12.5 KgHose (recommended) 51 mm 51 mm 51 mm 51 mm

All machines are constructed of corrosion resistant stainless steel.

VariColour Warning System Supplied as StandardVariColour Filter Blocked Warning:Alerts the operator when a filter starts to block so that areplacement can be acquired and downtime can be avoided.

Speed Control:Set the airflow rate to the optimum level.

Automatic Flow Control:To prevent loss of airflow as the filter becomes blocked, theclosed loop flow control system automatically adjusts thespeed of the motor to maintain a constant airflow throughoutthe life of the filter, thus making the filter last longer.

Features...• Automatic electronic flow control• Speed control• VariColour™ Warning System• Exceptionally low capital and running costs• No installation required• Submicronic particle and gas filtration • Massive HEPA main filter• Mobile design• Robust construction - high grade stainless steel• Excellent filter life• Whisper Stream™ - Quiet operation

Increase filter life andgain precise control.

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

Note: The previous model of FumeCube without a speed control knob requires different filters. Please contact your local distributor for advice.

FumeCube

- 49 -UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

E x t r a c t o r w i t h w o r k l a m p

Static MobileDescription: Code:230V 072110120V 072111

Supplied with:1 x Main filter1 x Pre-filter pad

Supplied with:1 x Main filter1 x Pre-filter pad1 x Mobile base with castors

Description: Code:230V 072112

Replacement Filters Replacement Parts

Pre-Filter PadDescription: Code:Pack of 4 200225 PCB (All models)

Code:400048

Main FiltersDescription: Code:HEPA/Chemical (std) 110536

BlowerDescription: Code:230V 300170/T120V 300174/T

NB: Previous 120V machines used the 230V blowers above witha factory fitted transformer. Check the serial number of yourmachine with Purex prior to order of replacements.

SpecificationUnit exPOD (Static) exPOD (Mobile)Voltage 230V ±10% 120V ±10% 230V ±10%Part number 072088 072095 072093 / 072094Wattage 0.14 kW 0.14 kW 0.14 kWSound rating 52 dBA 55 dBA 52 dBAFrequency 50Hz / 60 Hz 50Hz / 60 Hz 50Hz / 60 HzCabinet height (inc castors) 340 mm 340 mm 1100 mmCabinet width (not inc hose) 300 mm 300 mm 300 mmCabinet depth (not inc hose) 300 mm 300 mm 300 mmCabinet weight (inc filters) 12.5 Kg 12.5 Kg 14.5 KgHose (recommended) NA NA NA

Light BulbDescription: Code:Replacement Bulb 400589

- 50 -UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

FumeBuster A r m e x t r a c t i o n s y s t e m

Machine Only 2 x Conical Cowl SystemDescription: Code:230V 070362120V 070363

Supplied with:1 x Main filter1 x Pre-filter pad1 x Port blank (530430)

Supplied with:1 x Main filter1 x pre-filter pad1 x port blank (530430)2 x 1.2m x 75mm Ø flexible arms (120707) 2 x conical cowls (840114)

Description: Code:230V 040230120V 040110

2 x Plenum System (Clear) 2 x Plenum System (Black Anti Static)Description: Code:230V 040231120V 040111

Supplied with:1 x Main filter1 x pre-filter pad1 x port blank (530430)2 x 1.5m x 75mm Ø flexible hose (100185)2 x plenum cowls (clear) (120701)

Supplied with:1 x Main filter1 x pre-filter pad1 x port blank (530430)2 x 1.5m x 75mm Ø flexible hose (100185)2 x anti-static plenum cowls (black) (120702)

Description: Code:230V 040232120V 040112

2 x Cleancab System 2 or 3 x 38mm Arm SystemDescription: Code:230V 040233120V 040113

Supplied with:1 x Main filter1 x pre-filter pad1 x port blank (530430)2 x 1.5m x 75mm Ø flexible hose (100185)2 x Cleancab™ extraction cabinets (840155)

Supplied with:1 x Main filter1 x pre-filter pad1 x port blank (530430)2 x reducers 85-75mm (840113)2 x 0.6m x 75mm Ø flexible hose (570051)2 x reducers 78-57mm (550282)1 x 5.43m x 50mm straight pipe (520300)6 x 90° 50mm bends (520310)2 x 90° 50mm swept tees (520320)4 x 50mm straight connectors (520330)2-3 x clamp brackets (120180)2-3 x 38mm Ø flexible stainless steel arm / valve (120130)2-3 x 38mm Ø pen-nib nozzles (840170)

Description: Code:

2 x 38mm Arm System230V 040235120V 040237

3 x 38mm Arm System230V 040236120V 040238

Pre-Filter Pad (All models)Description: Code:Pack of 4 200314

Main FiltersDescription: Code:HEPA/Chemical (std) 110531Chemical 110532Cleanroom Filter 110535

SpecificationUnit FumeBusterVoltage 230V ±10% 120V ±10%Wattage 0.3 kW 0.3 kWSound rating 58 dBA 58 dBAFrequency 50Hz 60 HzMax flowrate 600 m3/hr 600 m3/hrCabinet height (inc castors) 345 mm 345 mmCabinet width (not inc hose) 420 mm 420 mmCabinet depth (not inc hose) 415 mm 415 mmCabinet weight (inc filters) 24 Kg 24 KgHose (recommended) 75 mm 75 mm

All machines are constructed of corrosion resistant stainless steel.

Replacement Filters

Replacement Parts

PCB (All models)Code:400049**This board is fitted to fumebusters FBC 525 to 532, also fromFBC 538 onwards. The board can be retro fitted in lieu of theoriginal (400048) if required, with the addition of 70mm of hose559999

BlowerDescription: Code:(230V) 300161/T(120V) 300162/T

KKiittss,,PPiippeewwoorrkk &&

AAcccceessssoorriieessFUME EXTRACTION SYSTEMSPUREX

- 52 -

Laserex Connection Kits Extractor to Laser Connect ion Ki ts

Ø 80mm to Ø 51mm. Alpha3m single head connection kit1 x 80-51mm reducer1 x 3m x 51mm flexible hose2 x 51mm cuffsCode: 100032

Marking / Coding Laser Engraving Laser Connection Kits

Ø 80mm to Ø 51mm. Alpha3m single connection kit1 x 80-53.5 mm reducer1 x 3m x 57mm flexible hose2 x 45-60mm hose clipsCode: 120285

Ø 80mm to Ø 100mm. Alpha2m single connection kit1 x 80mm female coupling2 x 70-90mm hose clips1 x 2m x 80mm flexible hose1 x 100-80mm reducer1 x 0.3m x 100mm flexible hose2 x 90-120mm hose clipsCode: 120288

Laserex Alpha & Xbase Connection Kits

Ø 80mm to Ø 51mm.6m single head connection kit1 x 80-51mm reducer1 x 6m x 51mm flexible hose2 x 51mm cuffsType Code:Std 100043PVC* 100043C* coated reducer

Marking / Coding Laser

Ø 80mm to Ø 51mm.6m twin head connection kit (Use with 100043 or 100043C)1 x manifold assembly1 x 6m x 51mm flexible hose2 x 51mm cuffsCode: 100039 *

* also suitable for PVC applications.

6m extension kit1 x aluminium coupling1 x 6m x 51mm flexible hose2 x 51mm cuffsCode: 100037

6m Flexible hose1 x 6m x 51mm flexible hoseCode: 570202

Ø 80mm to Ø 50mm.3m single connection kit1 x 80-53.5 mm reducer1 x 3m x 57mm flexible hose2 x 45-60mm hose clipsCode: 120285

Ø 80mm to Ø 100mm.2m single connection kit1 x 80mm female coupling2 x 70-90mm hose clips1 x 2m x 80mm flexible hose1 x 100-80mm reducer1 x 0.3m x 100mm flexible hose2 x 90-120mm hose clipsCode: 120288

LASER

0.3M x 100mm

3M x 80mm (cut to required length)

Ø 80mm to Ø 150mm.3m single connection kit1 x 80mm female coupling2 x 70-90mm hose clips1 x 3m x 80mm flexible hose1 x 100-80mm reducer1 x 0.3m x 100mm flexible hose2 x 90-120mm hose clips1 x 150-100mm reducer1 x 0.3m x 150mm flexible hose2 x 130-160mm hose clipsCode: 120289

LASER

0.3M x 100mm

3M x 80mm (cut to required length)

Laserex 210 / 400 Connection Kits

Ø 80mm to Ø 100mm. Xbase1m single connection kit1 x 80mm female coupling2 x 70-90mm hose clips1 x 1m x 80mm flexible hose1 x 100-80mm reducer1 x 0.3m x 100mm flexible hose2 x 90-120mm hose clipsCode: 120292

Xbase

Laser

0.3M x 100mm

2M x 80mm (cut to required length)

Ø 80mm. Xbase1.3m single connection kit1 x 80mm female coupling2 x 70-90mm hose clips1 x 1.3m x 80mm flexible hoseCode: 120293 Xbase

Laser

0.3M x 100mm

1M x 80mm (cut to required length)

Engraving Laser Connection Kits

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 53 -

Laserex Connection Kits Extractor to Laser Connect ion Ki ts

Ø 100mm.3m single connection kit1 x 3m x 100mm flexible hose2 x 90-120mm hose clipsCode: 100107

Marking / Coding Laser Engraving Laser

Ø 100mm.3m single connection kit1 x 100mm female coupling1 x 100mm equal tee2 x 3m x 100mm flexible hose4 x 90-120mm hose clipsCode: 120291

3M x 100mm (cut to required length)

3M x 100mm (cut to required length)

LASER Laserex

Laserex 800i Connection Kits

Ø 100mm to Ø 150mm.3m single connection kit1 x 100mm female coupling1 x 100mm equal tee4 x 90-120mm hose clips2 x 3m x 100mm flexible hose2 x 150-100mm reducers2 x 0.25m x 150mm flexible hose4 x 135-165mm hose clipsCode: 120294

3M x 100mm (cut to required length)

3M x 100mm (cut to required length)

LASER Laserex

Custom kit required. Please call.

Marking / Coding Laser Engraving Laser

Ø 150mm to Ø 100mm.3m single connection kit1 x 150mm female coupling1 x 150mm equal tee2 x 150 female couplings2 x 150-100mm reducers2 x 90-120mm hose clips2 x 3m x 100mm flexible hose2 x 90-120mm hose clips2 x 100mm female couplingsCode: 120287

Laserex 1500 / 2000 Connection Kits

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 54 -

Pipework Ø32mm, Ø50mm, Ø82mm

Ø 32mm

These kits connect Alpha,210 and 400 series

extractors to pipework.

LASEREXD I G I T A L

Ø32mm orØ50mm orØ82mm

Ø82mm

FUME EXTRACTION SYSTEMSPUREX

1 x 80-34mm reducer1 x Half straight connector1 x 1.5m x 41mm flexible hose1 x 40mm connecting pipe2 x 35-50mm hose clipsCode: 100170

Aluminium inletreducer (80-34mm)550283

Flexible hose(41IDmm)(per metre)570040

Flexible hose clip(35-50mm)580620

Aluminium inletreducer (80-53.5mm)550280

Flexible hose(57IDmm)(per metre)570050

Flexible hose clip(45-60mm)580630

Female inlet coupling80mm540025

Flexible hose(82IDmm)(per metre)570053

Flexible hose clip(70-90mm)580650

Ø 50mm

1 x 80-53.5mm reducer1 x 2m x 57mm flexible hose2 x 45-60mm hose clips

Code: 100180

Ø 82mm

1 x 80mm female coupling1 x 1.2m x 82mm flexible hose2 x 70-90mm hose clips

Code: 120262

Machine to Pipework Connections

21.5mm, 32mm, 50mm & 82mm Pipework

3.0m straight pipe520000

Straight connector520020

45º bend520070

90º bend520080

Spigot bend520100

Swept ‘T’520120

End blank520170

Pipe clip520180

Pipe reducer(50-32mm)520150

50 32

3.0m straight pipe500050

Straight connector500060

45º bend500070

90º bend500080

Swept ‘T’500100

End blank500120

Pipe clip500180

3.0m straight pipe500000

1.0m straight pipe500005

Straight connector500010

90º bend500020

Swept ‘T’500030

3.0m singlesocket pipe530110

45º bendsingle socket530180

90º bendsingle socket530190

Straight connector530170

Swept ‘T’530210

Socket plug530220

Pipe clip530120

Pipe reducer(82-50mm)530200

82 50

82mm Strap boss530160

50mm Boss adaptor530150

Ø 21.5mm Ø 32mm Ø 50mm Ø 82mm

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 55 -

Pipework Ø100mm, Ø150mm, Ø200mm

Ø 100mm GalvanisedThese kits connect 800,1500, 2000 and 4000 seriesextractors to pipework.

800 series (Ø100mm)1500, 2000 series (Ø150mm)4000 series (Ø200mm)

Contact Purex or your localagent for advice.

Connection kit1 x 100mm female coupling1 x 1.5m x 100mm flexible hose2 x 90-120mm hose clips

Code: 120270

Male safe coupling540122

Female coupling540120

Flexible hose(Ø102mm)(per metre)570060

Male safe coupling540315

Female coupling540320

Flexible hose(Ø152mm)(per metre)570070

Male safe coupling540610

Female coupling540701

Flexible hose(Ø200mm)(per metre)570071

Flexible hose clip (90-120mm)580660

Flexible hose clip(135-165mm)580670

Flexible hose clip(200mm)580675

Ø 150mm Galvanised

Connection kit1 x 150mm female coupling1 x 150mm male coupling1 x 1.5m x 150mm flexible hose2 x 135-160mm hose clipsCode: 120280

Ø 200mm Galvanised

Individual kits made using some of theparts below.

Ø100mm

Ø100mm

LASEREXD I G I T A L

FUME EXTRACTION SYSTEMSPUREX

Ø150mm

Ø150mm

LASEREXD I G I T A L

FUME EXTRACTION SYSTEMSPUREX

Ø200mm

Ø200mm

Machine to Pipework Connections

100mm, 150mm & 200mm Pipework

Ø 100mm Galvanised Ø 150mm Galvanised Ø 200mm Galvanised

3.0m spiral pipe540100

90º bend540133

45º bend540130

30º bend540129

Equal ‘T’540145

End cap540160

‘U’ bracket saddle540190

Butterfly valve540185

Equal ‘T’540337

End cap540400

‘U’ bracket saddle540450

Butterfly valve540440

3.0m spiral pipe540300

90º bend540345

45º bend540333

30º bend540328

Equal ‘T’540630

End cap540402

‘U’ bracket saddle540891

Butterfly valve540439

Pipe reducer(100mm-80mm)540150

100 80Pipe reducer(150mm-100mm)540382

150 100Pipe reducer(200mm-150mm)540640

200 150

3.0m spiral pipe540600

90º bend540620

45º bend540622

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 56 -

Arms and Accessories

Support collar and valveincluded. Select theappropriate captureapparatus from the listbelow.

* If required for a Fume-Cube, Fumebuster orLaserex connection kit usecode 120130

Code: 120135*

Stainless Steel Flexible arm38mm Ø

Multi-position arm54mm Ø

Pen-nib nozzle (38mm ID)Code: 840170Pen-nib nozzle (32mm ID)Code: 840172Pen-nib nozzle (25mm ID)Code: 840175

Delta cowl (290 x 5mm inlet)Code: 840180Delta cowl (192 x 5mm inlet)Code: 840182Delta cowl (90 x 12mm inlet))Code: 840185

Conical cowl (95mm ID)Code: 840190Conical cowl (90mm ID)Code: 840192Conical cowl (83mm ID)Code: 840195

Clear hood cowl (265 x 310mm)Code: 840160

38mm Capture Apparatus

Support collar and valveincluded. Select theappropriate captureapparatus from the listbelow.

* If required for a Laserexconnection kit use code120147

Code: 120140*

Pen-nib nozzle (54mm ID)Code: 120156

Clear hood cowl (265 x 310mm)Code: 120159

Delta cowl (160 x 10mm inlet))Code: 120157

Conical cowl (172mm ID)Code: 120158

54mm Capture Apparatus

ID Max D x H54mm 200 x 260mm38mm 180 x 190mm32mm 140 x 160mm25mm 100 x 100mm

D

H

D

H

L W

L W

Arm Ø Max W x L54mm 300 x 300mm38mm 300 x 200mm

D

H

D

H

L W

L W

Inlet Ø Max W x L160x20mm 300 x 300mm290x5mm 300 x 200mm192x5mm 200 x 150mm90x12mm 100 x 100mmD

H

D

H

L W

L W

ID Max D x H172mm 210 x 260mm95mm 190 x 200mm90mm 150 x 160mm83mm 110 x 150mm D

H

D

H

L W

L W

Capture Patterns

Telescopic arm54mm Ø

Support collar and valveincluded.

Arm supplied withtelescopic Pen-nib nozzle.

No other captureapparatus required.

Code: 120155

1 x 1m x 13mm Ø flexiblehose (grey)1 x ON/OFF tap1 x Mini arm base1 x 25mm Flexiblestainless steel arm1 x Mini delta nozzle

NB: This arm is equivalentto 5 x 5mm iron adaptorkits

Code: 120200

Mini Stainless Steel Flexible arm25mm Ø for solder pot extraction

Max D x H300 x 300mm

D

H

WL

Capture PatternsFlexible arm

100mm Ø x 2M

Supplied with conical cowland mounting bracket.

Code: 120175

1st Knuckle assemblyCode: 1201602nd Knuckle assemblyCode: 120161

Replacement knuckle joint assembly for multi-position and telescopic arms

Plenum cowlAnti static polycarbonate (black)Includes 50mm valve collar assemblyCode: 120703

Plenum cowlAnti static polycarbonate (clear)Includes 50mm valve collar assemblyCode: 120704

Flexible connecting hose(Ø57mm)(Per metre)Code: 570050

Screwed bench bracketCode: 840200/C

Clamped bench bracketCode: 120180

Wall bracketCode: 840210/C

Bench support collar and valveCode: 840047

Fixings

Plenum Cowls

Max W x L300 x 400mm

D

H

WL

Capture Patterns

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 57 -

Flexible hose(57IDmm)(per metre)Code: 570050

Flexible hose clip(45-60mm)Code: 580630

Connections Image

Arms and Accessories

Standard Options Hood or Base Only Options Special Options

860mm

615mm

627mm

305mm

150mm

455m

m

365m

m

512mm

Includes:BaseOpen Hood50mm Airflow valveCode: 840150

50mm

Includes:BaseOpen Hood75mm Exhaust portCode: 840155

75mm

Includes:BaseClosed Hood50mm Airflow valveCode: 840162

50mm

Includes:Downdraught BasePerforated steel plateOpen HoodCode: 840164

Includes:Open Hood50mm Airflow valveCode: 840159

Special options are available on the cleancab system.

These include:• Water taps• Drainage points• Multiple extract ports• Access for electrical connections• Perforated steel workplate

If your requirements are not shown here contact Purex oryour local supplier.

Optional Tap Kit

Includes:Open Hood75mm Airflow valveCode: 840171

Includes:Open HoodCode: 840151

Includes:Closed HoodCode: 840154

Includes:Closed Hood50mm Airflow valveCode: 840174

50mm

Includes:Downdraught BasePerforated steel plateCode: 840161

CleanCab Extraction Unit

Clear Hoodwith Exhaust Point

Base Unit

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

Depth = 510mm

- 58 -

Tip Kits & AccessoriesScrew in adaptor (580010) Blanking plug (580100)

Extended Quick Release Kit (100110)

ON/OFF Tap Kit (100120)

Quick Release Adaptor Kit (100100)

Bulkhead Connection Kit (100090)

Extended ON/OFF Tap Kit (100130)

Description CodeMini Weller iron adaptor kit 1000651 x extraction tube clip 8300501 x 6mm Ø x 135mm extraction tube 8301121 x 1.5m x 5mm ID x 1.5mm wall 560010clear silicone hose4 x 8mm Ø hose clips 5805211 x soldering iron stand 8300081 x cup 8300051 x screw in adaptor (8mm hose, M10) 580010Standard Weller/RS/Adcola iron adaptor kit 1000601 x extraction tube clip 8300401 x 6mm Ø x 100mm extraction tube 8301101 x 1.5m x 5mm ID x 1.5mm wall 560010clear silicone hose4 x 8mm Ø hose clips 5805211 x soldering iron stand 8300081 x cup 8300001 x screw in adaptor (8mm hose, M10) 580010Large Weller iron adaptor kit 1000701 x extraction tube clip 8300411 x 7mm Ø x 150mm extraction tube 8301151 x 1.5m x 6mm ID x 1.5mm wall 560030clear silicone hose4 x 8mm Ø hose clips 5805211 x soldering iron stand 8300081 x cup 8300021 x screw in adaptor (8mm hose, M10) 580010Pace iron adaptor kit 1000721 x extraction tube clip 8300651 x 6mm Ø x 100mm extraction tube 8301101 x 1.5m x 6mm ID x 1.5mm wall 560030clear silicone hose4 x 8mm Ø hose clips 5805211 x soldering iron stand 8300081 x cup 8300021 x screw in adaptor (8mm hose, M10) 580010Metcal iron adaptor kit 1000751 x extraction tube clip 8300501 x 6mm Ø x 135mm extraction tube 8301121 x 1.5m x 5mm ID x 1.5mm wall 560010clear silicone hose4 x 8mm Ø hose clips 580521Universal iron stand 8300071 x screw in adaptor (8mm hose, M10) 580010Antex iron adaptor kit 1000851 x extraction tube clip 8300501 x 6mm Ø x 225mm extraction tube 8301351 x 1.5m x 5mm ID x 1.5mm wall 560010clear silicone hose4 x 8mm Ø hose clips 580521Universal iron stand 8300071 x screw in adaptor (8mm hose, M10) 580010Hakko iron adaptor kit 1000302 x extraction tube clip 8300501 x 6mm Ø x 225mm extraction tube 830136

Accessories for 3-10 Tip and Superflow™ systems

Description CodeMetcal/Mini Weller iron adaptor kit 1000661 x extraction tube clip 8300501 x 6mm Ø x 135mm extraction tube 8301121 x 1m x 6mm ID x 1mm wall 560025black silicone hose4 x 8mm Ø hose clips 5805211 x soldering iron stand 8300081 x cup 830005

Standard Weller/RS/Adcola iron adaptor kit 1000571 x extraction tube clip 8300401 x 6mm Ø x 100mm extraction tube 8301101 x 1m x 6mm ID x 1mm wall 560025black silicone hose4 x 8mm Ø hose clips 5805211 x soldering iron stand 8300081 x cup 830000

Antex iron adaptor kit 1000771 x extraction tube clip 8300501 x 6mm Ø x 225mm extraction tube 8301351 x 1m x 6mm ID x 1mm wall 560025black silicone hose4 x 8mm Ø hose clips 5805211 x universal iron stand 830007

Accessories for portable systems

Description CodeConnection kitsScrew in adaptor (8mm hose, M10) 580010Blanking plug 580100Quick release adaptor kit 100100ON/OFF tap kit 100120Bulkhead connection kit 100090Extended quick release kit 100110Extended ON/OFF tap kit 100130Spare ON/OFF tap 580080Tube cleaning brushes5mm bronze 8302006mm bronze 8302108mm bronze 830220Iron standsUniversal iron stand 830007Airflow meter5-50l/min 33020010-100l/min 330201

General Accessories

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 59 -

Miscellaneous Kits82mm Ø pipe kit to cater for 2 arm extraction stations3m of 82mm single socket pipe1 x 82mm straight connector1 x 82mm plug socket1 x hole saw set 26mm-63mm plus,2 x arm connection kits, each containing1 x 82mm strap boss1 x 50mm boss adaptor1 x 1m x 50mm Ø flexihose2 x hose clips 45-60mm1 x 0.032m x 50mm plain pipeCode: 100167

32mm Ø pipe kit to cater for 5 tip extraction stations6 x 1.5m x 32mm Ø straight pipe4 x 32mm Ø straight connectors4 x 32mm Ø 90º elbow joints2 x 32mm Ø ‘T’ joints2 x 32mm Ø end blanks5 x 8mm Ø x M10 thread adaptors5 x M10 thread blanking plugs

Code: 100165

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

Cascade Box

Standard VersionDescription: Code:Volume Machines 890169Vacuum Machines 890180

Supplied with:1 x Cascade filter

SpecificationUnit Cascade Box (Standard Version) Cascade Box (Air Pulsed Version)Voltage NA NAPart number 890169/890180 890214/890222Wattage NA NASound rating NA NAFrequency NA NACabinet height (inc castors) 1063 mm 1063 mmCabinet width (not inc hose) 430 mm 430 mmCabinet depth (not inc hose) 430 mm 430 mmCabinet weight (inc filters) 30 Kg 40 KgHose (recommended) NA NA

All machines are constructed of corrosion resistant stainless steel and are mounted on four castors for increased mobility

Replacement Filters

Cascade FilterDescription: Code:Needlefelt 111107

The Cascade Box acts as an additional prefilter to capture particles in applications where large amounts are produced. The filter can be emptiedwhen full. The standard version requires the operator to periodically shake the filter to increase filter life. The Cascade Box is available in twoversions:Volume: For Laserex and Powerflow machinesVacuum: For Xbase, Alpha, Superflow Tip and Arm machines

Custom Connection Kit

Connection kits are available for all types and models of associated machinery and applications.We also offer a design service for custom installations. See accessories section.

- 60 -

Order Form

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

- 61 -UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

Terms & Conditions

TERMS & CONDITIONSUnless otherwise agreed in writing by the Seller all goods are supplied in the following terms andconditions to the exclusion of any terms and conditions stipulated by the Buyer and any previousrepresentations, warranties or communications not expressly incorporated herein.

FORMATION OF CONTRACTQuotations unless previously withdrawn, shall be valid for a period not exceeding 30 days from date oftender (unless otherwise stated). No order shall be deemed accepted until the Seller’s writtenacknowledgement thereof has been made and subject only to the terms and conditions stated below.Any stipulations or conditions in the Buyer’s order form which would conflict with these conditions or inany way qualify or negate the same shall be deemed to be inapplicable to the order placed with theSeller unless expressly agreed to by the Seller in writing when acknowledging the order in question.

VARIATIONS OF CONDITIONSUnless otherwise agreed in writing by the Seller the goods are supplied by the Seller only on theseconditions and no variation of or addition thereto (whether contained in any document emanating fromthe Buyer or made orally by any person acting or purporting to act on behalf of the Seller) shall haveeffect unless it is in writing signed by or on behalf of the Seller. Should any of these conditions conflictwith any conditions stated in the Buyer’s order, these conditions shall prevail. The giving by the Buyerof any delivery instructions for the goods or any part thereof or the acceptance by the Buyer of deliveryof the goods or any part thereof or any conduct by the Buyer in confirmation of the transaction set outon the basis hereof after receipt by the Buyer of this document shall constitute unqualified acceptanceby the Buyer of these conditions.

ACCEPTANCE OF ORDERSAll orders must contain sufficient information to enable the Seller to supply and or manufacture thegoods required. No liability can be accepted for incorrectly ordered goods.

NEW ACCOUNTSCredit accounts cannot be opened under the minimum amount in operation at the time of placing theorder. Customers wishing to open a credit account must furnish two trade references and a banker’sreference.

TELEPHONE ORDERSTelephone orders will be accepted only if an official order number is quoted in all cases. If telephonedorders are confirmed in writing they must be clearly marked “Confirmation.” If duplication occurs dueto the order thus not being marked delivery must be accepted.

FACSIMILE ORDERSFacsimile orders will be deemed to be binding contracts subject to the Seller’s standard terms andconditions.

PRICE VARIATIONSThe Seller shall be entitled to adjust the purchase price of the goods whether before or after the making of the agreement to which these conditions relate in the event of any variation in the cost to theSeller of supplying the goods or any part thereof, caused by any reason whatsoever beyond the controlof the Seller including (without prejudice to the generality of the foregoing) changes in exchange ratesor the action of any government or authority. Any increase in delivery charges imposed by the Sellerafter the date of confirmation of order shall be for the account of the Buyer. The minimum charge inoperation at the time of placing the order must be accepted.

PASSING OF PROPERTYThe property in the goods shall not withstanding delivery to the Buyer remain in the Seller until theBuyer has paid the full price as well as all other sums whatsoever due to the Seller i.e. goods are heldin a fiduciary capacity by the Buyer until payment is received. If at any time payment of the price orany other sums due to the Seller is overdue, the Seller may by its servants or agents enter upon theBuyer’s premises and recover and dispose of the goods and the Buyer shall make no claim against theseller in respect of such entry or disposal.

PASSING OF RISKThe risk in goods supplied overland shall pass to the Buyer on delivery to the Buyer’s designatedpremises or to the carrier nominated by him (whichever shall first occur.) The risk in goods supplied bysea or air transport shall pass to the buyer on delivery to the carrier nominated by the Buyer in whichcase the Seller will at the Buyer’s written request, cost and risk, arrange for the Buyer’s expressinstructions as to transit and packaging for sea or air transport to be carried out.

DELIVERY BY INSTALMENTSIf any order for goods is to be delivered by several instalments to the Buyer each instalment shall betreated as a separate and identifiable contract and the rights of either party there under shall beconstrued accordingly, save only that the seller may suspend delivery thereof whilst payment isoverdue in respect of any previous instalment if the Seller shall fail to make delivery or shall makedefective delivery of any instalment such failure or defective delivery shall not affect the obligations ofthe parties under the contract of which these conditions form part in respect of the other instalments.

CARRIAGE AND PACKINGCarriage and packing will be charged at cost plus a handling fee unless otherwise specified in writing.Express or Special Delivery at the Buyer’s request will always be at the buyer’s expense. Prices donot include VAT which is chargeable in the U.K. on transport and post.

NON-DELIVERY/LOSS/DAMAGE/DEFECTThe Seller shall be notified in writing on the non-receipt of any goods by the Buyer or his nominatedcarrier within seven days of the invoice date in the U.K. or within ten days of the expected arrival at theoverseas port or airport for Export customers, failing which the Seller shall be under no liabilitywhatsoever to the Buyer who shall nevertheless hold the Seller indemnified against any loss arising ordamage suffered through the failure to inform the carriers or insurers within the required time limits.The Buyer must notify the Seller of any alleged defect in or damage to the goods within ten days ofactual receipt and thereafter shall be deemed to have accepted the goods in all respects. Any suchnotice must specify the particular defect and must afford the seller reasonable opportunity to inspectthe goods in question. If the goods are agreed by the Seller to be defective or faulty the Seller will (atits option) either rectify the defect or fault or replace any such goods or credit the invoice value of thegoods and such rectification or replacement or credit will be in full satisfaction of any claim by theBuyer.

CONSEQUENTIAL LOSSThe Seller shall be under no liability whatsoever (including without prejudice to the generality of theforegoing any liability in tort or for consequential loss or damage of any kind) for breakage or resultingdefect occurring after delivery for any defect in or failure of or unsuitability for any purpose of the goodsor any part thereof whether the same be due to any act omission negligence or wilful default of theSeller or its servants or agents or to faulty design, workmanship or material or any other causewhatsoever, including (without prejudice to the generality of the foregoing) any breach by the Seller, itsservants or agents of any fundamental term or any fundamental breach by the Seller, its servants oragents of any term of the contract of which these conditions form part, and all other conditions,warranties or other terms whether express or implied, statutory or otherwise inconsistent with theprovisions of these conditions are hereby expressly excluded.

PENALTY CLAUSES

Penalty clauses on Buyer’s order or contracts cannot be accepted unless a specific undertaking inwriting is secured from the Seller covering each order or contract concerned. Such an undertaking willnot be regarded as valid unless signed by a director of the Seller.

FORCE MAJEUREThe Seller shall do all in its power to perform the terms of any contract of which these conditions formpart, in particular to meet all delivery dates but shall not be liable for any failure to observe or breach ofany of the terms hereof by reasons of acts of God, war, riots, civil commotion’s, strikes, lock-outs, tradedisputes, fires, breakdowns, interruptions of transport, Governmental action, delay in delivery by theSeller’s suppliers or any other cause whatsoever beyond its control, the time for delivery shall beextended until such cause shall have ceased to operate in such circumstances except where goodsare in transit the Seller may terminate the unperformed part of any contract of which these conditionsform part by notice in writing delivered to the Buyer within fourteen days of the occurrence of suchaction or circumstances as makes the Seller fail to observe or break the terms hereof without incurringany liability by reason of such determination.

RETURNSGoods supplied can be returned only if the Seller’s permission is first obtained. Permission will only beconsidered if the goods are those which the Seller regularly carries in stock. All returns are subject to arestocking charge.

RECOMMENDATIONSWhilst all written recommendations made by the Seller as to the treatment of the goods are made ingood faith and in the belief that they are correct, the Seller shall have no responsibility whatsoever forany damage liability cost claim or expense suffered by the Buyer or any third party through followingsuch recommendations.

SPECIFICATION ALTERATIONSThe Seller reserves the right to alter the specification of any goods without prior reference to the Buyerprovided that the goods comply in all other known respects with the Buyer’s requirements.

TRADE-MARKS/PATENTSThe supply of goods by the Seller shall not confer any right upon the Buyer to use any Seller’s trade-mark without prior written consent of the Seller and at all times such trade-mark shall remain theproperty of the Seller. Neither does it imply any right to use any Seller’s patent or any indemnityagainst infringement of third party patents.

DELIVERYDelivery dates or periods are given in good faith and the Seller will make every effort to meet them butno liability is accepted for failure to deliver on a specified date or within a specified period.

INDEMNITYThe Buyer shall indemnify the Seller against all claims in respect of any loss, injury or damagesustained by a third party, however caused after receipt of the goods by the Buyer and shall also payand indemnify the Seller against all royalties or other payments in respect of any patents, registereddesigns or other rights which may be claimed as a result of goods being made according to design orspecifications supplied by the Buyer and shall indemnify the Seller against all claims, expenses andcosts in connection with any infringement or alleged infringement of any patent, registered design orother right in the manufacture of such goods.

LIABILITYa) The seller will use his best endeavours to obtain for the Buyer the benefit of any warranty in respectof the goods (including any undertakings to repair or replace defective parts) which the Seller receivesfrom his own suppliers in relation thereto.b) The Seller’s liability in terms of these conditions is in lieu and to the exclusion of all other warranties,conditions or obligations imposed by statute or otherwise in relation to the quality or description of thegoods or their fitness for any particular purpose.c) All liability for consequential or indirect loss or damage howsoever arising is hereby expresslyexcluded.

ASSIGNMENTThe Buyer shall not, without the Seller’s prior written consent, assign or transfer or purport the contractto which these conditions relate or the benefit thereof to any other person whomsoever.

INDULGENCENo indulgence or forbearance extended to the Buyer shall limit or prejudice any right or claim availableto the Seller.

PAYMENTa) The Buyer shall pay the amount invoiced in accordance with the Seller’s payment terms. Paymentfor the goods is due on delivery, but, at the discretion of the Seller, may not be enforced for net thirtydays after delivery.

b) If the Buyer fails to make payment by the due date, then without prejudice to any other right orremedy available to the Seller, the Seller shall be entitled to:I) Suspend any further deliveries to the Buyer until payment is made in full.ii) Appropriate any payments made by the Buyer to such of the goods (or the goods supplied underany other contract between the Buyer and the Seller) as the Seller may see fit (notwithstanding anypurported appropriation by the Buyer), andiii) Charge the Buyer interest (both before and after any Judgement) on the amount unpaid at the rateof four per cent (4%) per annum above the Barclays Bank plc base rate from time to time until paymentin full is made (a part of the month being treated as a full month for the purpose of calculating interest.

CANCELLATIONa) If the Buyer shall fail to make any payment when it becomes due or shall enter into any compositionor arrangement with its creditors or if being an incorporated company shall have a receiver appointedor shall pass a resolution for winding up or a Court shall make an order to that effect or if not being anincorporated company shall have a receiving order made against it or if there shall be any breach bythe Buyer of any terms and conditions hereof, the Seller may defer or cancel any further deliveries andtreat the contract of which these conditions form part as determined but without prejudice to its right toany unpaid purchase price of goods delivered and to damages for any loss suffered in consequencethereof.b) Orders are not subject to cancellation, change reduction in amount or suspension of deliveriesexcept with Seller’s consent and upon terms which protect the Seller from loss.

CATALOGUESCatalogues and other advertising matter are issued to indicate the type and range of goods we offerand no particulars therein are binding to the Seller.

STATUTORY RIGHTSNothing herein contained is intended to affect nor will it affect a consumer’s statutory rights.

LAWThis contract shall in all respects be construed and operate as an English contract and all mattersarising there under shall be determined in accordance with the laws of England.

- 62 -

Contact Details

Purex International LtdPurex HouseFarfield ParkManversRotherhamS63 5DBUKTelephone: +44 (0)1709 763000Fax: +44 (0)1709 763001Email: [email protected]

Websites:www.purexltd.co.ukwww.solderfume.co.ukwww.laserfume.com

Registered Office. Purex International Ltd. Purex House, Farfield Park, Manvers, Rotherham, S63 5DB. Registered No. 5136616 England. VAT No. GB842 5025 49

Purex Americas1290 Lakeside Drive

GurneeIllinois

IL60031USA

Telephone: 001 866 360 5675 Toll FreeFax: 001 866 360 5676 Toll FreeEmail: [email protected]

WEEE Producer Registration Number:WEE/CE0067TX

UK • T: (0)1709 763000 F: (0)1709 763001 USA (Toll Free) • T: 866 360 5675 F: 866 360 5676

FUME EXTRACTION SYSTEMSPUREX