1 www.powdersolutions.com GUIDE FOR MAGNET SELECTION & VALIDATION in FOOD PROCESSING PULL TESTING vs GAUSS TESTING October 2016 Prepared by Active Magnetics Research Pty Ltd. Consulting Reference HACCP International and Food Safety Standard MAGSEP 12010

Transcript of PULL TESTING vs GAUSS TESTING - Powder … FOOD PROCESSING PULL TESTING vs GAUSS TESTING ......

Page 1: PULL TESTING vs GAUSS TESTING - Powder … FOOD PROCESSING PULL TESTING vs GAUSS TESTING ... Conclusion 3: Gauss tests, instead of, or in addition to pull tests are related to …

    

1  

www.powder‐solutions.com

GUIDEFORMAGNETSELECTION&VALIDATION

inFOODPROCESSING

PULLTESTINGvsGAUSSTESTING

October2016PreparedbyActiveMagneticsResearchPtyLtd.

ConsultingReference‐HACCPInternationalandFoodSafetyStandardMAGSEP1‐2010

Page 2: PULL TESTING vs GAUSS TESTING - Powder … FOOD PROCESSING PULL TESTING vs GAUSS TESTING ... Conclusion 3: Gauss tests, instead of, or in addition to pull tests are related to …

    

2  

www.powder‐solutions.com

Introduction:Thefollowingreview,writtenbyWilliamJBaker,SeniorConsultantofActiveMagneticsResearch,isprovidedforthebenefitofqualityobjectivesofglobalfoodindustryin2016.Fundamentaltothispaperistheassertionthatneitherhighestpulltestorhighestgausstestmeasurementsaloneprovethesemagnetswillprovidethebestperformanceinreal‐lifemagnetinstallations.

Review:Neodymiummagnetshaveenabledtheredesignofgrateandbarmagnetstosuitmodernsafefoodprocessing,wheretheemphasisformagnetshasshiftedfrompreventionofequipmentdamageanddowntimecausedbytrampiron,tofoodsafetyandproductpurity.In2016foodindustrypractice,wemustefficientlyextract<1/8”fragmentsofweaklymagneticSSchips,scrapingsandmetaldustfrombecomingspecsofunwantedcontaminationinfinaloutgoingproductsorpassedtotheconsumerinfinishedproduct.Obviously,peakperformancemagnetsareessentialfordaytodaycontinuingprotection.Asanaddedbenefit,effectivemagnetswillreduceproductwastageandsavetimesearchingforcausesofmetaldetectorrejections. 

Notonlymustwepreventmachinerydamageandproductiondowntime,butpreventbrandnamedamageandcostlyproductrecallsfrommetalcontaminations.Wemustextractwhatmetaldetectorsand/orx‐rayequipmentmaymiss.Peakperformingmagnetswillreducefalserejectsfrommetaldetectorsandx‐rayequipment,andallowthemtoperformattheirbestsensitivity.Youmayask…..1) HowdoIreallyknowifmymagnetsarepeakperformers?2) HowdoIknowthatoriginalpeakperformingmagnetshavenotlosteffectivestrengthsince

beingnew?Itistheobjectiveofthispapertoclarifythesecriticalissues.Thesearethevitalquestionsdemandingaccurateanswerstosatisfythoseresponsibleforriskreduction,maintenanceofcompanyqualityandbrandimage;anddiscriminatingengineersresponsibleforselectionandmaintenanceofeffectiveprocessequipment.

Question1/HowdoIreallyknowifmymagnetsarepeakperformers?Ifthemagnetisthefinalmagnetpriortopackaging,verifyitconformstoHACCPInternationalFoodSafetyStandard0909MAGSEP1‐2010‐atleastintermsofgaussstrengthandpolecentres.

Page 3: PULL TESTING vs GAUSS TESTING - Powder … FOOD PROCESSING PULL TESTING vs GAUSS TESTING ... Conclusion 3: Gauss tests, instead of, or in addition to pull tests are related to …

    

3  

www.powder‐solutions.com

Whatconstitutes‘MagnetPerformance’infoodmillingandrelatedfoodindustriesoperatingunderaHACCPorsimilarriskandhazardcontrolprocess?

“Itistheabilityofmagnettoextractthehighestpercentageofweaklymagneticandtypicalmagneticcontaminationfoundinfoodstreamspriortooutgoingproduct”.

Additionally;BesidesSTRENGTH(pulltestorgausstest)andPOLECENTRES(distancebetweenhighstrengthpolebands)thereareotherfactorstoconsiderwhichareveryimportantwhenevaluatinglongtermoptimumperformingmagnetinstallations,whenfoodsafetyandproductpurityiscritical.

Whatarethemeasuresofthisperformanceinorderofimportance?1) Most10,000gausscollectionpoles(22mmcentresorless)inagivenbarlength.2) Longestlinearlengthofcollectionpolespergivenbarlength.3) Locationtoavoiddownstreamre‐contamination(nearesttopacking).4) Sizingtomagneticallycovertheproductstreamwithoutblockage.5) Bestmagnetstrengthretentionmeasures,asconfirmedbycertifiedmagnetvalidationsto

detectdeclinefromoriginalstrength.6)Themagnetshapewillefficientlyretainmagneticsextracted.7) Easiestdesigntoregularlycleanoffcollectedfragmentstomaintainseparating efficiencyofacleanmagnet.Furtherrecommendationsforassuringoverallmagneticseparationefficiency:

Considerinstallingadditional10,000gaussmagnetsofattheearliestintakepositionstoconfirmingredientsarefreeofmagnetics

Bestpracticeshouldincludemagnetstoremovebulkofmagneticssuchasstainlesssteel&ferroustramp,rustandmagneticstonetoavoidmachinerydamageandgrindingoflargermagneticstofineweaklymagneticparticles.

Intermediatemagnetshelptoavoidoverloadingoffinalmagnetsparticularlywherethepackingmagnetissmalldimensionally.

ExposingaMAGNETICSEPARATIONMYTH:Reviewingsomerecentmagnetmanufacturerstestsandclaims,itseemsthatpulltestresultsareoftenpresentedinawaytoencouragetheconclusionthatmagnetbarsshowingthehighest“pulltest”averagearethereforethehighestperformers.Thisisdefinitelynotthecaseinsensitivefoodmagnetapplications.

Page 4: PULL TESTING vs GAUSS TESTING - Powder … FOOD PROCESSING PULL TESTING vs GAUSS TESTING ... Conclusion 3: Gauss tests, instead of, or in addition to pull tests are related to …

    

4  

www.powder‐solutions.com

Whileblindtestingandgoodtestingmethodologymaybeused,the“objective”and“conclusions”ofthesetestsneedtobeclarified.Higherpulltestreadingsareeasilyengineered,butseparationperformancedoesnotnecessarilyequatewithhighestpulltestreadings!Pleasereferdiagram‘A’below.Diagram“A”

 Explanation:Bywideningtheinnermildsteelpoleplatebetween2magnetsinrepulsion,wecaneasilyelevatethepullteststrength,butthisreducesthegaussfluxdensity.Thetrickisthatpolecentresarethenwidenedinordertoachievespecifiedgauss.ThisresultsinthehigherpulltesttubebeinglessefficientasdepictedinmoredetailinDiagram‘B’below.TheinnermildsteelpoleplateiswiderinMagnet#1,thereforemorelinesofforcepassthroughthe¼”diametermildsteelballresultinginthehigherpulltestreading.Thismagnetwillholdtightertolargeandmediumtrampiron>than¼”ballsize.ThismagnetcircuitdoesnotconformtotheMAGSEPstandardforfinalmagnets,butcouldbeselectedformachinerydamagepreventionapplications.Inordertomaintainspecifiedfluxdensity(gauss)readings,noticeinMagnet#1thatpolecentresofhighestpulltestmagnetsarewiderapart!Thisistoutilisetheextraenergyofalongerinnermagnet‐verysignificantwhenitcomestoselectingthebestperformerforriskreductionandproductfreeof<1/8”fragmentsandfineweaklymagneticcontamination,whichisourmainobjectiveinsensitivefoodrelatedindustries.PleasereferDiagram‘B’below. 

Page 5: PULL TESTING vs GAUSS TESTING - Powder … FOOD PROCESSING PULL TESTING vs GAUSS TESTING ... Conclusion 3: Gauss tests, instead of, or in addition to pull tests are related to …

    

5  

www.powder‐solutions.com

Diagram“B” 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Explanation:Magnet#2hassimilargaussasMagnet#1,however,itisamoreefficientontypicalmagneticcontaminants,astherearemorehighstrengthpolebandsandlessdeadareasaroundthecentrelinebetweenpolebands.Assumingpulltestandgaussstrengthisidenticalamagnetbarwith25mmpolecentreswillbelessefficientonfineweaklymagneticcontaminationsand30mmpolecentresevenlessefficient.TheInternationalStandardforFinalMagnets0909MAGSEP1‐2010recognises10,000gauss@22mmpolespacing’sasmaximumpermittedpolecentresforfinalmagnetsinafoodprocessingoperationoperatingunderaHACCPriskcontrolprogram.Thisisimportantsofineandweaklymagneticparticlescanattractandholdtothehighstrengthpolebandsduringtheirmillisecond

Page 6: PULL TESTING vs GAUSS TESTING - Powder … FOOD PROCESSING PULL TESTING vs GAUSS TESTING ... Conclusion 3: Gauss tests, instead of, or in addition to pull tests are related to …

    

6  

www.powder‐solutions.com

passagearoundthemagnettubeorbar.Ifpolecentresarewidermanysuchfragmentsaredeflected,butmayescapebeforebeingretained,astheDiagram“B”shows. 

Conclusion1:Themagnetwiththehighestpulltestwillhold¼”andlargerferrouspiecestothemagnetbarwithmarginallymoreforceandmaybeselectedwherethemagnetisnota“finalmagnet”orwheretheprimeimportanceistoextractsmalltomediumtrampironforpreventionofequipmentdamage.

Conclusion2:Highestgaussattheshortestdistancebetweenpolecentersshouldbeselectedasthebestperformerwheretheprimarydutyistoextract<1/8”fragments,fineandweaklymagneticcontaminations.TheintendeddutyanddesiredresultsofthemagnetMUSTbeconsideredwhenselectingordesigningthebestperformingmagnetforthejobandnot“pulltest“or“gaussreading”testresultsalone.Theengineerselectingmagneticseparatorsshouldaskthequestion,“Whatarethecentredistancesbetweenthehighstrengthpolebandsalongthebar?”Caution:10%moreinpulltestvaluewithlongerpolecentresmaymean20‐30%lessseparatingefficiency–specifyamaximumof22mmpolecentresforfinalandothercriticalmagnetsmagnets.

Conclusion3:Gausstests,insteadof,orinadditiontopulltestsarerelatedtopotentialperformanceofmagnetinstallations.Thegausstestismorequantitative,gauss/teslabeinganSIderivedunit.Pulltestinouncescanvarytoshowelevatedreadingsifthewidthofpoleplatesisvaried.Acalibratedgaussmeteristhemoreoverallreliableindicatorofpotentialmagneticseparationperformance.

Conclusion4:Sincebotharereliablecomparativeinstruments,digitalcalibratedpulltestersordigitalcalibratedgaussmetersareequallysuitablefordetectingandtrendingmagnetstrengthlossovertimeonmagnetsoriginallydeterminedtohavegaussreadingsandpolespacing’sconformingtotheMAGSEPStandard.

Page 7: PULL TESTING vs GAUSS TESTING - Powder … FOOD PROCESSING PULL TESTING vs GAUSS TESTING ... Conclusion 3: Gauss tests, instead of, or in addition to pull tests are related to …

    

7  

www.powder‐solutions.com

Question2/HowdoIknowthatoriginalpeakperformingmagnetshavenotlosteffectivestrength?Sinceintroductionofthenewcalibratedinstrumentation,calibrateddigitalpulltestersorgaussmetersarebothanaccuratemeansofmeasuringandtrendingDECLINEinmagneticstrengthfromnewmagnetratingscomparingthesamemagnet/sovertime.Itisrecommendedinthe0909MAGSEP1‐2010Standardthatfinalmagnetsbetestedatleastonceyearlyusingarecentlycalibratedgaussmeter.Theresultsofthesetestscantrendmagnetstrengthdeclineandhelptopinpointearlydemagnetisationduetounforeseenfactorssuchas;

• Temperatureabovethemagnetoperatingtemperaturerating,• Thermalshock,• Corrosion,• Excessivevibration,• PoororcheapRareEarthMagnetsoflowcoercivityrating,• Roughhandlingandimpactbypersonsdoingthemagnetcleaning.

Summary,Specifications&EfficiencyTips;

• Pullstrengthtestsandgaussstrengthtestsshouldnotbeusedasthesolebasistoselectbetweenmagnetsofdifferentmanufacturers.

• Inallcircumstances,itisimportanttoconsider‘whatistheprimeoressentialdutyofthemagnetandtoselectthebestperformingfieldpatternfortrampironprotectionorfinalmagnetsproductpurity.PleaserefertoDiagram“B”onPage6.

• Haveparticularregardforsuitabilityofmagnetdesigntonotlosefragmentsdefinedas<1/8”weaklymagneticandfinecontamination,whicharethebiggestmagneticandmetalcontaminationconcernsinthefoodindustry.

• Calibrateddigitalpulltestersorgaussmetersarenowequallyeffective,reliableandaccurateforcomparingmagnetstrengthlossofanindividualorsetofinstalledmagnetsovertime.

• Whenselectingformagneticseparationefficiency,consider“polecentres”aswellas“strength”.7/8”(22mm)maximumissafefortubesandbarsupto2”diameter.

Highperformingfinalmagnetsandothercriticalmagnetswilluseneodymiumironboronmagnetsofhighcoercivityandresistancetothermalshock,suchasRE80HTorequivalentwithexcessservicetemperatureratingofpreferably302F/150°C.

Page 8: PULL TESTING vs GAUSS TESTING - Powder … FOOD PROCESSING PULL TESTING vs GAUSS TESTING ... Conclusion 3: Gauss tests, instead of, or in addition to pull tests are related to …

    

8  

www.powder‐solutions.com

• Highperformancefinalmagnetswillalsobesizedforcorrectcoverageofproductstreamandlocatedatorimmediatelyupstreamofpackingorout‐loading.

• Lowergradeorwiderpolecentregratemagnetsoflowercostmaybesuccessfullyusedasmagneticintakescalpingmagnetsoratlargeareabagopeningorblendstationsupstreamoffinalmagnets.Regularmagnetcleaningisessential.

• Ifconsideringself‐cleaninggratetypemagnets,ensurethebarsaresolidandwithoutsleeves,whichareverythintoachievesurfacestrength,butareverysusceptibletoimpactdamageduringcleaningcycles.Also,ensurethereisaneffectivemechanismforequalisingbarabrasionandpreventingbuildupandblockage.MAG‐RAM™separatorsandRotarygratesprovidethesebenefitsinherently.

• DrummagnetsandPlatemagnetshavelongservedwellforremovingheavyanddamagingsizetrampironatintakesandatindividualHammermills,Pinmills,Rollmills,etc.topreventdamageandproliferationofgroundupmagneticmaterial.

• Finally,highperformance,small,lowcost“indicatormagnets”arebecomingpopularforplacingontopofintakeorbagopeninggratesalsointakeblowlines.Theseneedtobesamespecificationasfinalmagnetstoseparateworkhardenedstainlesssteelparticles,etc.

Addendum:THEBELOWTESTRESULTSARETHEBASISSUPPORTINGTHEFACTSANDOPINIONSEXPRESSEDINTHISPAPER.METHOD:

Magnetsinrepulsionwereplacedina1”diametertubeandcompressedwithcircuitvariationscomprising,2mmand4mmwidemildsteelpoleplatesbetweenthem.

Samegrademagnetswereusedtoavoidvariationfromcauseofdifferentgradesusedbydifferentmanufacturersoftubeandbarmagnets.

Samethicknesstubeandstainlesssteelwereusedoneachtesttopreventvariationsfromothercauses.

Calibratedgaussandpulltestmeterswereusedtorecord8readingsontheexternalofthetubeonthecentrelineofeachpoleplatewithmagnetlengthsof20mmand30mm.

Readingsweretherebyrecordedat22mmpolecentres,24mmpolecentres,32mmpolecentresand34mmpolecentres.Thereadingswereaveragedasshownintheresultstable.

8readingsweretakenwitheachinstrumentandaveraged(BrandEandAMRpulltesters,Gaussmeter)

 

Page 9: PULL TESTING vs GAUSS TESTING - Powder … FOOD PROCESSING PULL TESTING vs GAUSS TESTING ... Conclusion 3: Gauss tests, instead of, or in addition to pull tests are related to …

    

9  

www.powder‐solutions.com

OBSERVATIONS:

TheBrandEpulltesterreadslightlyhigherthantheAMRinstrument,butwellwithinnormal2%or3%instrumentvariationtolerance.

Gaussmeterreadingswereconsistentwithusualfieldtestreadingsonthesemagnetpolecentrevariations.

RESULTS:

PoleCentrePolePlateWidth

MagnetLength

AverageGaussAverageEriezPullTest

AverageAMRPullTest

0.866”/22mm 0.0787″/2mm 0.787”/20mm 10,694gauss 90.46oz 89.6oz

0.945”/24mm 0.1575”/4mm 0.787”/20mm 9,634gauss 99.18oz 99.0oz

1.26”/32mm 0.0787″/2mm 1.181”/30mm 11,472gauss 93.53oz 92.6oz

1.34”/34mm 0.1575”/4mm 1.181”/30mm 9,987gauss 98.92oz 99.0oz

 

EXPLANATION: 2mmwidepoleplatesgavethehighestgaussandshortestpolecentres,butlowestpulltest

value. Widerpoleplatesgavehighestpulltestvalue,longerpolecentres,butlowergaussvalue. Longermagnetelementswith2mmwidepoleplates,substantiallyincreasedgauss,slightly

increasedpulltestvalue,butgreatlyincreasedpolecentres. Longermagnetelementswith4mmwidepoleplatesgreatlyreducedthegauss,maintained

thehigherpulltestvaluebutfurtherincreasedthepolecentres.ThefiguresforgaussandpulltestconfirmthatpullinouncesisnotanSIvalue,meaningthereisnotanequivalentratiobetweengaussfluxdensityandouncepulloveravarietyofmagnets.ThisisthereasonpulltestsarenotallowedintheHAACPInternationalStandardasbasisforcertifiedmagnetvalidations.

Page 10: PULL TESTING vs GAUSS TESTING - Powder … FOOD PROCESSING PULL TESTING vs GAUSS TESTING ... Conclusion 3: Gauss tests, instead of, or in addition to pull tests are related to …

    

10  

www.powder‐solutions.com

WehavealreadydepictedinDiagramBabovethatbecausemorelinesoffluxpassthrougha¼”pulltestballwhenwiderpoleplatesareusedwithinthemagnettube,thismakesthepullvaluehigheralongwithmarginallymoreholdontrampiron3mmandlargerinsize.However,thediagramalsoshowsthathighgaussandshortpolecentresismoreimportantwhenthedutyistoextractandholdweaklymagneticfragmentslessthan3mminsize.Especially,sincethemiddleofeachmagnetinanytubemagnetcircuitis”nilgauss”and“nilpull”.Contaminateparticlesmustmovetothehighgausspolebandsasproductmovespastthemagnetbar.Sincemagneticgaussandpullisalwaysweakatadistancefromthemagnetbar,allmagnetsinsensitivefoodstreamsshouldbedesignedforproductcontact.Theargumentthathigherpullonsurfaceandhigherpullatdistancemeasuredwitha¼’mildsteelballdoesnotproverelevant.Separationoffineandweaklymagneticfragmentsrequiresspecifiedfluxdensityingaussanddistancebetweenpolesastheessentialperformancefactors.Whereproductflowpermits,staggeredmagnetbarsorsplitterbarsorangledeflectorsmaybeusedtofurtherraisemagneticseparationefficiency.

CONCLUSION: 

FoodSafetyStandard0909MAGSEP1‐2010forfinalmagnetsinafoodrelatedprocesscorrectlyspecifiesfinalmagnetsshouldbeaminimumof10,000gaussat22mmpolecentres.

Themostefficientmagnetgratetubeorbarforseparatingfineandweaklymagneticcontaminationisnotthemagnetshowinghighestpulltestvalue.Themostefficientmagnetwillhavethehighestgaussatshortestdistancebetweenpolebandscentres.TheMAGSEPStandardcurrentlyexcludespulltestinstruments.However,HACCPInternationalhasconfirmedthatmagnetvalidationsusingcalibratedpulltestinstrumentsmaybeacceptableprovidedthefirstvalidationincludedcalibratedgaussvaluesaspertheStandard. 

 

AMRMagnetValidationReportscanincludebothgaussandpulltestvalues.AMRMagnetValidationReportsarecertifiedbyHACCPInternationalandareavailableglobally.

Page 11: PULL TESTING vs GAUSS TESTING - Powder … FOOD PROCESSING PULL TESTING vs GAUSS TESTING ... Conclusion 3: Gauss tests, instead of, or in addition to pull tests are related to …

    

11  

www.powder‐solutions.com

ForMagnetvalidationsconformingtoHACCPInternationalFoodSafetyStandard0909MAGSEP1‐2010,lookfortheHACCPCertificationLogoasshownbelow.

CONSULTINGREFERENCE: USAREPRESENTATIVEFORAMR:HACCPInternational D.L.Newslow&AssociatesNorthSydney,Australia Florida,USAwww.haccp‐international.com www.newslow.com

USAREPRESENTATIVEFORMAGNATTACK:

Powder‐Solutions,Inc.Chanhassen,MNwww.powder‐solutions.com