Published August 2012 Comprehensive Electric Blowers Fans ...
Transcript of Published August 2012 Comprehensive Electric Blowers Fans ...
Electric Blowers Fans/Blowers Environmental Equipment Dust Collectors
Catalog No. A4-13-02EPublished August 2012
Comprehensive Catalog of Blowers
Safety Precautions
Before using your product, carefully read the Operating Instruction Manual
for a thorough understanding of the proper product usage.
The contents of this catalog presuppose transactions and use in Japan only.
Business Items
Electric Blowers
Providing Hospitality to the Environment
Low-noise seriesHigh-pressure seriesMulti-stage seriesAll-purpose seriesGeneral-purpose seriesFlange-installed seriesStainless-steel seriesExplosion-proof seriesLarge-sized seriesDenchokuHigh-pressure vortex series blowersGust BlowerAgitating/circulating series(Double Volute)
�
�
�
�
�
�
�
�
�
�
�
Fans/BlowersTurbofansDelturboTurbo blowersAirfoil fansSirocco fansPlate fansAxial flow fans with variable blade pitchKairyu
�
�
�
�
�
�
Environmental EquipmentMist collectors MistresaPortable fansWind Bag
�
�
Dust CollectorsDustresa• Compact series• Small-sized pulse jet series• Moveable open-type series• Pulse jet seriesFumeresa
�
�
*The contents of this catalog are subject to change without prior written notice.Visit our Website to view the latest version of the catalog.
*We are currently delivering CAD data through the Website.
For environment protection, this catalog is printed on recycled paper using soybean oil ink.
Head office: 1-25 Shinden Kitamachi, Daito City, Osaka 574-0052 JapanFounded: June 29, 1950Sales: 6.6 billion yen (achievements in fiscal 2011)E-mail: [email protected] main award histories: Awarded minister of economy in 2006
<IT management promotion section>Distributor locations: Thailand, Brazil, China, France, Germany, India, Indonesia, Korea, Malaysia,
Philippines, The U.K., The U.S.A., Vietnam etc...
Distributor
1 2
http://www.showadenki.co.jp
You can download performance curve sheets and dimensional outline drawings from our Website. Here is the procedure:
Conditional search
1. Click the Search button on the first page of the window.
2. Select one of two search methods:
You can search for a product by specifying its model.
This function allows you to search for a product by specifying the appropriate product group and specifications/requirements.
1
Enter one-byte alphameric characters into the Air Volume/Static Pressure field (mandatory).Next, click the Search button.
The corresponding products will be displayed.A click of the button will display detailed product information.
Enter the model.
Pressing the button corresponding to necessary material will allow you to download the material.
Pressing the button corresponding to necessary material will allow you to download the material.
Notes:- If the desired material is not downloaded by
the click, select [Save target in file] by right-clicking to save the material.
- You need to use the appropriate CAD software (dfx file) to view CAD data.
Notes:- If the desired material is not downloaded by
the click, select [Save target in file] by right-clicking to save the material.
- You need to use the appropriate CAD software (dfx file) to view CAD data.
Clicking the button on the detailed product information display window will change window control to the following window:
Clicking the button on the detailed product information display window will change window control to the window shown at right.
Model search2
The corresponding products will be displayed.A click of the button will display detailed product information.
Download Material from the Website
Catalog Download
Click the Catalog Download button on the first page of the window.
Pressing the button corresponding to necessary material will allow you to download the material.
Blower Perform
ance Curve Sheet
A1D (Axial �ow fan) 50HzA1D (Axial �ow fan) 60HzA2D (Axial �ow fan) 50HzA2D (Axial �ow fan) 60Hz
P.19P.20P.19P.20
KT (Airfoil fan)M1V (Sirocco fan)P1V (Plate fan)GP (Plate fan)
P.11P.13P.15P.17
T1V (Turbo fan)T2V (Turbo fan)B2V (Turbo blower)B3V (Turbo blower)
P.5P.7P.9P.10
A1V (Axial �ow fan)A2V (Axial �ow fan)CM (Agitating fan)CA (Agitating fan)Electric blowerDenchoku
P.21P.21P.23P.24P.25P.27
3 4
Blower Performance Curve Sheet
B2
GP
T1V
T2V
P1
A2D(60Hz)
A2D(50Hz)
M1V
KT
A1D(50Hz)
A1D(60Hz)
B3
10.09.08.0
7.0
6.0
5.0
4.0
3.0
2.0
1.5
1.25
1.00.90.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
Static pressure (kPa)
1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 7080 90100 125 150 200 300 400 500600700800900 1500 20001000 1750 2250
900070005000300010000800060004000
Air volume (m³/min)
Turbo Fan T1V
5 6
T1V-Type Turbo Fan Delturbo with V-Belt Drive
40
36
3228
24
22
2018
16
14
12
10
08Nominal number
� Type T1V⓪⑧ (Nominal number)
� Uses Dust remover and collectorHot blast circulatorDryerIncinerator
Smoke exhaust apparatusCombustion apparatusBoilerFood/chemicals related equipment
Air blower/exhaust apparatus for various plant equipmentMiscellaneous
4.03.83.53.23.0
2.5
2.2
2.0
1.8
1.5
1.2
1.0
0.8
0.6
0.5
0.4
0.3
0.2
0.1
10 20 40 60 80 100 120 150 200 250 300 400 500 600 800 1000 1200 1500 20002200
Air volume (m³/min)
Features
A low-pressure high-capacity type. With a multi-purpose impeller applicable to collecting a small amount of dust as well.Actual applicability depends on the quality and amount of dust. Please contact us for further details.
Static pressure (kPa)
Notes:- Further detailed dimensional outline drawings and performance curve
sheets can be downloaded from our Website.
Turbo Fan T2V
T2V08 kW ※ p
※ m3/min V
※ kPa kW
2225 min-1
90
80
70 1
60
0.8
1.2 0.6
0.8 0.4
0.4 0.2
0 0 0
0 10 20 30 40 50
図番 昭和電機株式会社 伊賀工場DWG.№ SHOWA DENKI CO.,LTD. IGA FACTORY
T2V12STDMAX4.6K_0.92_0.15標 4
品名/形式TYPE
May.25.2006
2006.5.25
M.MATSUURA性 能 曲 線 図 PERFORMANCE CURVE
作成DRAW
作成日DATE
承認APPROVE Y.UCHIDA
CTB0820-Y010
kg/m31.2
電動機MOTOR
軸動力SHAFT POWER
Hz
※
※周波数FREQUENCY
風 量VOLUME
備 考NOTES
密 度 DENSITY
電 圧VOLTAGE
温 度TEMPERATURE 20℃
※
-
※印仕様は、仕様書による。※ REFER TO SPECIFICATIONS.
静 圧STATIC PRESSURE
回転速度/回転数FAN SPEED
20
THE MEASURING POINT AWAY
1m FROM OPENING
吸込
口正
面1
m位
置
40
80
60
風量 (m3/min)Volume
全圧効率Fan Eff.
静 圧St Press.
軸 動 力Shaft Power
騒 音 dB(A)
Noise
騒 音 dB(A)
Noise
騒 音Noise
静 圧 (kPa)
St.Press.
軸動力 (kW)
Shaft Power
全圧効率 (%)
Fan Eff.
7 8
10.0
8.0
9.0
Static pressure (kPa)
6.0
5.04.5
4.0
3.5
3.0
2.5
2.22.01.8
1.5
1.2
1.0
0.8
0.6
0.4
0.2
0.1
10 20 30 40 60 80 100 120 150 200 250 300 400 500 600 800 1000 1200 1500 2000
4036
32282422
2018
161412
10
08Nominal number
T2V-Type Turbo Fan Delturbo with V-Belt Drive FeaturesA middle-pressure high-capacity type. This fan has load-limiting characteristics to prevent motor overloading due to changes in shaft power according to design point.
� Type T2V⓪⑧ (Nominal number)
� Uses Dust remover and collectorHot blast circulatorDryerIncinerator
Smoke exhaust apparatusCombustion apparatusBoilerFood/chemicals related equipment
Air blower/exhaust apparatus for various plant equipmentMiscellaneous
Air volume (m³/min)
Notes:- Further detailed dimensional outline drawings and performance curve
sheets can be downloaded from our Website.
Turbo Blower B2V/B3V
12.0Static pressure (kPa)
9.5
10.0
11.0
9.0
8.5
8.0
7.5
7.0
6.5
6.0
5.5
5.0
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
4 5 10 15 20 30 40 50 60 70 90 11080
140120100
Air volume (m³/min)
9 10
B2V-Type Turbo Blower with V-Belt Drive B3V-Type Turbo Blower
10
06
10
05
08
04
06
03
05
12.0
11.5
11.0
10.5
10.0
9.5
9.0
8.5
8.0
7.5
7.0
6.5
6.0
5.5
5.0
4.5
4.0
Static pressure (kPa)
10 15 20 25 30 35 40 50 60 7080
90100 120110
140130 150
Air volume (m³/min)
Nominal number
Nominal number
Features
� Type B2V⓪③ (Nominal number)
� Uses For burner combustion airSecondary positive blowerAir transport apparatusDust collector
Apparatus related to air pollution controlHot blast blower for use in drying furnaces or annealing furnacesBlower for air conditioningAir supply/exhaust apparatus for various plant equipment and others
An energy-saving noise-reduction type of blower based on Non-Surger concept (Showa Denki's own technology).
Notes:- Further detailed dimensional outline drawings and performance curve
sheets can be downloaded from our Website.
Airfoil Fan KT
11 12
KT-Type Airfoil Fan with V-Belt Drive
3.13.0
Static pressure (kPa)
2.8
2.6
2.4
2.22.12.0
1.8
1.6
1.4
1.2
1.1
1.0
0.8
0.6
0.5
0.4
0.3
0.2
20 30 40 50 60 80 100 120 150 180 200 220 250 300 400 500 600 800 1000 1200 14001600
18002000
220024002600
Air volume (m³/min)
Notes:- Further detailed dimensional outline drawings and performance curve
sheets can be downloaded from our Website.
Features
0090
8070
60
55
5045
403530
� Type KT-③⓪ (Nominal number)
� Uses Air conditioning and ventilation in o�ce buildings and factoriesDryersCooling and air supply/exhaust for equipmentAir supply and exhaust for general applications
UV apparatusDehumidi�erWind tunnel test apparatusCoater and others
Nominal number
The bladed impeller of this fan ensures high
efficiency, low noise, and a large air volume.
Sirocco Fan M1V
13 14
M1V-Type Sirocco Fan with V-Belt Drive
1.10Static pressure (kPa)
1.00
0.90
0.80
0.70
0.60
0.50
0.45
0.40
0.35
0.30
0.25
0.20
0.15
0.10
0.08
0.06
0.05
20 30 40 60 80 100 120 150 200 250 300 400 500 600 800 1000 1200 1500 1800 2200 280030002000 2500
Air volume (m³/min)
Notes:- Further detailed dimensional outline drawings and performance curve
sheets can be downloaded from our Website.
A large-capacity low-pressure type, best suited to
the applications requiring a large volume of air.Features
36
32
40
28
24
22
2018
1614
12
10
0806
� Type MIV⓪⑥ (Nominal number)
� Uses Air conditioning and ventilation in o�ce buildings and factoriesDryersCooling and air supply/exhaust for equipmentAir supply and exhaust for general applications
Wind tunnel test apparatusMiscellaneous
Nominal number
Plate Fan P1V
15 16
P1V-Type Plate Fan with V-Belt Drive
� Type P1V⓪⑧ (Nominal number)
� Uses PowderDust collector for solids/�brousBoilerDryer
Air transport apparatusIncineratorFan for potentially corrosive gasesAir supply/exhaust for use with various equipmentMiscellaneous
3.00Static pressure (kPa)
2.50
2.80
2.202.102.00
1.80
1.50
1.20
1.00
0.80
0.60
0.50
0.40
0.30
0.25
0.20
0.18
0.160.15
10 15 20 25 30 40 50 60 80 100 120 150 200 250 300 400 500 600 800 1000Air volume (m³/min)
Features
28
24222018
16
1412
10
08Nominal number
A large-capacity low-pressure type.This fan is best suited to transporting air from powder or solids and to processing the high-concentration gases that contain dust.
Notes:- Further detailed dimensional outline drawings and performance curve
sheets can be downloaded from our Website.
Plate Fan GP
17 18
GP-Type Plate Fan with V-Belt Drive
6.0Static pressure (kPa)
4.5
4.85.05.2
5.5
5.8
4.2
4.0
3.8
3.5
3.2
3.0
2.8
2.6
2.4
2.2
2.0
1.8
1.6
1.4
1.2
1.1
1.0
20 25 30 40 50 60 80 100 110 120 140 160 180200
210220
240260
280300
Air volume (m³/min)
A middle-pressure type. This fan is best suited to transporting air from powder
or solids and to processing the high-concentration gases that contain dust.Features
50
45
40
35
30
25
20
� Type GP-②⓪ (Nominal number)
� Uses PowderDust collector for solids/�brousBoilerDryer
Air transport apparatusIncineratorFan for potentially corrosive gasesAir supply/exhaust for use with various equipmentMiscellaneous
Nominal number
Notes:- Further detailed dimensional outline drawings and performance curve
sheets can be downloaded from our Website.
Motor-Connected A
xial-Flow Fan
19 20
Axial Flow Fan with Variable Blade Pitch (A1D type and A2D type) "Kairyu"
Notes:- Further detailed dimensional outline drawings and performance curve
sheets can be downloaded from our Website.
Motor-Connected type
1010
1010
99
9 9
88
8 8
77
7
66
6
6
55
5 5
44
4
4
3
3
33
A1D 60HzA1D 50Hz
A2D 50Hz A2D 60Hz
A low-noise type that reduces noise by up to about 15 dB (A).Direct driving by direct connection to a motor shaft eliminates the need for maintenance such as belt tension adjustment and belt replacement.In addition, rotating sections are housed inside the machine to ensure human safety.
Features
0.5
1.8 1.71.6 1.51.41.3
1.21.1
1
0.8
0.60.5
0.40.350.30.25
0.2
0.15
0.120.1
0.08
0.450.4
Static pressure (kPa)
Static pressure (kPa)1.61.4
1.2
1.5
1.3
11.1
0.8
0.6
0.5
0.40.35
0.3
0.250.220.20.180.16
0.15
Static pressure (kPa)
0.350.30.250.220.20.180.15
0.120.1
0.08
0.060.05
0.04
0.030.025
0.02
0.7
0.50.550.6
0.45
Static pressure (kPa)
0.40.350.3
0.25
0.20.18
0.15
0.12
0.1
0.080.070.060.0550.050.0450.04
10
20 25 30 40 50 60 80 100 120 150 200 300 400 500 20 30 40 50 60 80 100 120 150 200 250 300 400 500600700 900 1100 1300 1500800 1000 12001400
600700 900 11001300800 1000 1200
15 20 25 30 40 50 60 80 100 120 150 200 250 300 400 5006007008009001000
Air volume (m³/min)
10 15 20 25 30 40 50 60 80 100 120 150 200 250 300 400 500600700800900 11001000
Air volume (m³/min)
Air volume (m³/min)
Air volume (m³/min)
� Type A1D③ (Nominal number)
� Uses Air supply and exhaust at tunneling worksitesGeneral air conditioningAir supply and exhaust in industrial plantsVentilation in basements
Air conditioning at underground parking areasO�ce buildings air conditioningMiscellaneous
Nominal numberNominal number
Nominal number
Nominal number
Axial-Flow
Fan with V-Belt
21 22
Axial Flow Fan with Variable Blade Pitch (A1V type and A2V type) "Kairyu" V-belt Features
Notes: - This fan is manufactured on a custom-design basis. Please contact our sales department for further details. The telephone numbers and addresses of our sales offices and branches are listed on the back cover of this catalog.
0.9
0.8
0.7
Static pressure (kPa)
0.60.55
0.5
0.45
0.4
0.35
0.3
0.25
0.2
0.18
0.15
0.12
0.1
0.08
0.07
0.06
0.05
0.04
0.03
0.02
0.9
0.8
0.7
Static pressure (kPa)
0.60.55
0.5
0.45
0.4
0.35
0.3
0.25
0.2
0.18
0.15
0.12
0.1
0.08
0.07
0.06
0.05
0.04
0.03
0.02
60 100 120 180 220 300 40045080 110 150 200 250 350500
600700
800900 11001000
Air volume (m³/min)
60 100 120 180 220 300 40045080 110 150 200 250 350500
600700
800900 11001000
Air volume (m³/min)
10
10
8
8
7
7
6
65
5
9
9
Without in-tube cover With in-tube cover
Since the fan speed can be adjusted by changing a combination of pulleys, multiple units of performance can be set up with one fan.
Agitating CM/CA
23 24
CM In-Furnace Agitating Fans with V-Belt Drive
0.5Static pressure (kPa)
0.45
0.4
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
0.5Static pressure (kPa)
0.45
0.4
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
20 30 40 50 60 80 100 120 150 200 250 300350400450500
600700800
10001200
65.5
54.543.53
2.521.5
Air volume (m³/min)100
110120
140160
180200220
250300
350 450 550 700 900400 500 600 800 1000
Air volume (m³/min)
7∅500
∅600 ∅700∅800
∅900∅1000
A sirocco type of
agitating fan.Features
CA In-Furnace Agitating Fans with V-Belt Drive
An axial-flow type
of agitating fan.Features
Notes: - This fan is manufactured on a custom-design basis. Please contact our sales department for further details. The telephone numbers and addresses of our sales offices and branches are listed on the back cover of this catalog.
Electric Blowers 50H
z/60Hz
Not useable on ranges.Not useable on ranges.Not useable on ranges.
25 26
Electric Blowers
50Hz 60Hz
Electric Blowers
Notes:- Further detailed dimensional outline drawings and performance curve sheets can be downloaded from our Website.
Notes:- Further detailed dimensional outline drawings and performance curve sheets can be downloaded from our Website.
3.2
2.8
2.0
1.6
0.2
0.8
0.4
0
3.0
2.5
2.0
1.5
1.0
0.5
0
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
2.0
1.6
1.2
0.8
0.4
0
5.0
4.0
3.0
2.0
1.0
0
0.6
0.5
0.4
0.3
0.2
0.1
0
2.0
1.6
1.2
0.8
0.4
0
8.0
10.0
6.0
4.0
2.0
0
16.0
14.0
18.0
10.0
12.0
8.0
6.0
4.0
2.0
0
30.0
25.0
20.0
15.0
10.0
5.0
0
3.2
2.4
1.6
0.8
0
2.8
2.0
1.2
0.4
6.0
4.0
5.0
3.0
2.0
1.0
0
0.7
0.5
0.3
0.6
0.4
0.2
0.1
0
2.4
2.0
1.6
1.2
0.8
0.4
0
28.0
24.0
20.0
16.0
12.0
8.0
4.0
0
4.0
3.5
2.5
1.5
0
3.0
2.0
1.0
0.5
2.8
2.4
2.0
1.2
1.6
0.8
0.4
0
14.0
12.0
8.0
10.0
6.0
4.0
2.0
0
20.0
17.5
15.0
10.0
12.5
7.5
5.0
2.5
0
35.0
30.0
25.0
20.0
15.0
10.0
5.0
0
15.0
18.0
21.0
24.0
12.0
9.0
6.0
3.0
0
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
50Hz
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
0 5 10 15 20 25 30 35 40 0 20 40 60 80 120100 0 5 15 25 3510 20 30 40 0 20 60 100 12040 80 140
0 4 12 208 16
0 10 30 5020 40 605 25 4515 35 55
0 0.8 1.6 2.40.4 2.01.2
0 4 8 102 6
0 10 3020 40 50 60 70 0 21 3
0 4020 603010 50
0 42 531
0 10 20 30 40 7050 60 0 1 2 3
0 20 40 605 25 4510 30 5015 35 55 0 20 40 6010 30
0 12 164 8 0 0.6 1.4 1.80.2 1.00.8 1.60.4 1.2
0 3 7 81 542 6
50
0 2 4 4.51 3
EC-63S/T
EC-75S/T
EC-125
SB-201/202
AH-H37
AH-H07
AH-H10
AH-H15
AH-H22AH-H04
FS-2200
U2V-220
U100B-H55U100B-H56
U100B-H45U100B-H46 U100B-H35
U100B-H36U100B-H5
U75-H4
U75-H3U75-H2 U100B-H26
U2V-150
U2V-70T
U2V-40T
U2V-30T
U2V-20T
U2V-10TU2V-07T
U2V-220U2V-150
U2V-70T
U2V-40T
U2V-30T
U2V-20T
U2V-10T
U2V-07T
FS-1500FS-750FS-400
FS-200FS-150
FS-2200
FS-1500FS-750
FS-400
FS-200FS-150
SF-55S
SF-50
SB-151SF-38
SB-201/202
AH-H37AH-H07
AH-H10
AH-H15AH-H22
AH-H04
SF-55S
SF-50
SB-151SF-38
EM-125M2
SBT-600
KSB-H07B KSB-H15BKSB-H15KSB-H22BKSB-H22
KSB-H07
KSB-H37B
KSB-H37
KSB-H04
U2V-70S
U2S-370
U2S-220
U2S-750U2S-150
U2S-70T
U2S-40T
U2V-40S
U2V-30SU2V-20S
U2V-10S
U2V-07S
SBT-600P
SB-600SB-600PSB-150
SF/SB-100SF/SB-75
SB-180
SBT-600
U100B-H56U100B-H46
U100B-H36
U75-H5
U100B-H26U75-H4U75-H3U75-H2
KSB-H37
KSB-H37B
KSB-H22
KSB-H15B
KSB-H22BKSB-H15
KSB-H07
KSB-H07B
KSB-H04
U2V-70S
U2S-370
U2S-220 U2S-750
U2S-150
U2S-70T
U2S-40T
U2V-40S
U2V-30S
U2V-20S
U2V-10S
U2V-07S
SBT-600P
SB-600
SB-600PSB-150
SF/SB-150
SF/SB-75
SB-180
EC-100S/T
EM-100T7
EC-63S/T
EC-75S/T
EC-125
EM-125M2
EC-100S/T
EM-100T7
Not useable on ranges.
Not useable on ranges.Not useable on ranges.
Not useable on ranges.
Not useable on ranges.Not useable on ranges.
Not useable on ranges.
All-purpose series Low-noise series
High-pressure series General-purpose series
General-purpose series Flange-installed series
Multi-stage series High-pressure vortexseries blowers
(U2V single-phase)
High-pressure vortexseries blowers
(U2V three-phase)
All-purpose series
High-pressure series
General-purpose series
Multi-stage series
High-pressure vortexseries blowers
(U2V three-phase)
High-pressure vortex series blowers (U2S)
Low-noise series
General-purpose series
Flange-installed series
High-pressure vortexseries blowers
(U2V single-phase)
High-pressure vortex series blowers (U2S)
A motor shaft directly connected blower of aluminum-molded casing construction. About 20,000 models are available.
Features
Denchoku 50H
z/60Hz
27 28
Notes:- Further detailed dimensional outline drawings and performance curve sheets can be downloaded from our Website.
Notes:- Further detailed dimensional outline drawings and performance curve sheets can be downloaded from our Website.
2.4
0.8
0.6
0.4
0.2
0
1.2
0.8
1.0
0.6
0.4
0.2
0
2.0
1.6
1.2
0.8
0.4
0
4.5
3.5
2.5
1.5
0.5
2.0 6.0
5.0
4.0
3.0
2.0
1.0
0
1.6
1.2
0.8
0.4
0
7.0 10.0
9.0
8.0
7.0
6.0
5.0
6.0
5.0
4.0
3.0
2.0
2.0
1.6
1.2
0.8
0.4
0
1.6
1.2
0.8
1.0
0.6
0.4
0.2
0
3.0
2.6
2.2
1.8
1.4
1.0
0.6
3.0
2.5
2.0
1.5
1.0
0.5
0
10.0
9.0
8.0
7.0
6.0
5.0
4.0
1.2
0.8
0.4
0
2.8
1.6
0.8
1.2
0.4
1.0
6.0
5.0
4.0
3.0
2.0
1.0
6.0
5.0
4.0
3.0
2.0
1.0
0
15.0
14.0
13.0
12.0
11.0
10.0
9.0
2.4
1.6
0.8
0
2.2
1.8
1.4
1.0
0.6
0
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
K1D typeAirfoil fan
M2D typeSirocco fan
T1D typeTurbo fan
T2D typeTurbo fan
B1D typeTurbo blower
K1D typeAirfoil fan
M2D typeSirocco fan
T1D typeTurbo fan
T2D typeTurbo fan
B1D typeTurbo blower
0
0 20 40 60 80 100 200
0
0
20
20
40
40
60
60
80
0 10 20 30 40 50 60
80 100 120
50 100 150 200 0 100 200 400300 500 600 0 50 100 150 200
10 50 210130 17090 250
0 20 12010060 8040 140
60 100 260180 220140 280
0 100 300200 400
0 100 300200 500400 600
0 20 6040 80 100
0 10 3020 5040 60
10 30 70 11050 90 130
20 40 80 12060 100 1400 100 200 300 400
0 40 80 12020 60 100 140
0 100 200 300 350
0 60 120 240180 300
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Static pressure (kPa)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
Air volume(m³/min)
This type, compared with the V-belt driven type, saves a floor area requirement by about 50% and uses fewer parts and accessories. In addition, it requires no belt tension adjustment.
Features
K1D4③
K1D5②K1D5①K1D4②
K1D4①
K1D5②K1D5①
K1D4②
K1D4①
K1D6①
M2D3①
T1D4①
T2D4①
B1D5①
B1D6①
B1D7①
B1D5①
B1D6①
B1D7①
T2D4② T2D4③
T2D5①
T2D5②
T2D6①T2D6② T2D6③
T2D5③
T2D4①
T2D4② T2D4③
T2D5①
T2D5②
T2D5③
T1D4②
T1D5① T1D5②
T1D4①
T1D4②
T1D5①
M2D5①
M2D4③
M2D4②
M2D5②
M2D5③
M2D3②M2D3③M2D4①M2D3④
M2D3⑤
M2D3⑥
M2D3①
M2D3⑥
M2D5①
M2D5②
M2D3②M2D3③M2D4①M2D3④
M2D4③
M2D3⑤
M2D4②
K1D6②K1D7①K1D7②K1D8①K1D8②K1D9①K1D9②
K1D6①
K1D6②K1D7①K1D7②
K1D8①K1D8②
M2D2⑥M2D2⑤
M2D2④
M2D2③
M2D2②
M2D1②
M2D2①
M2D2①
M2D2⑥
M2D2④
M2D2⑤
M2D2②
M2D2③
M2D2①
M2D1②
M2D1①
T1D3②
T1D3①
T1D2②
T1D2①
T1D3②
T1D3①T1D2②
T1D2①
T2D3③
T2D3②
T2D3①
T2D2③
T2D2②
T2D2①
T2D3③
T2D3②
T2D3①
T2D2③
T2D2②
T2D2①
B1D4①B1D3①
B1D2①
B1D1①
B1D4①
B1D3①
B1D2①
B1D1①
50Hz 60Hz
Denchoku (Motor-Connected Type of Welded Construction)
Heat-resistant fan connected directly to motor shaft Stainless steel sirocco fan
Agitating fan
Teflon-coated coupling turbofan
Emergency exhaust gas engine fan
Wear-resistant fan
Wind tunnel test apparatus
29 30
Custom-design cases
Motor shaft-connected fan resistant to high temperatures up to 350 degrees
Fan for stirring up air in a tempering furnace
Teflon-coated fan highly resistant to corrosion
Sirocco fan for dryers
This fan is engine-driven to allow operation even in an emergency such as a power interruption.
Plate fan designed to withstand wear
This wind tunnel test apparatus uses the variable blade pitch axial-flow fan "Kairyu" of 900 mm in diameter.
(Approx. size: 8.3 m x 3.2 m)
Showa Denki's fans and blowers support various custom designs.Here are examples of actual custom products:
In-furnace agitating axial-flow fan
Fan for agitation in drying furnaces
This test apparatus uses the high-efficiency large-capacity variable
blade pitch axial-flow fan "Kairyu". Inside the wind tunnel, a
wire mesh and straightening plates, as well as a honeycomb
structure, are provided to maintain a uniform in-channel
cross-sectional airflow for straightening. The diameter of the outlet
port is 500 mm, and the maximum velocity is 50 m/s (180 kmph).
Custom-design cases
(Turbo fan)Air volume: 220 m3/min, Static pressure: 2.58 kPaMotor: 15 kW, 2P, 50 Hz� Intake air temperature: 350 deg (maximum)� Bearing: Air-cooled type� Others: Despite resistance to high temperatures, Denchoku (direct motor
shaft connection) speci�cations provide the highly e�cient, compact design.
(Sirocco fan)Air volume: 620 m3/min, Static pressure: 0.3 kPaMotor: 7.5 kW, 4P, 60 Hz� Material: SUS304 for gas contact region� This fan was manufactured to suit the dimensional limits of the user
equipment.� The motor is mounted on top of the casing to implement the compact
design.
(Turbo fan)Air volume: 45 m3/min, Static pressure: 2 kPaEngine output: 4.3 kW� Shaft seal: Bypass labyrinth seal (Construction in which the high-pressure gas
at the shaft seal is suctioned using an intake-side vacuum pressure to minimize leakage from the shaft seal)
� Others: Anti-vibration rubbered frame and intake/outlet expansion coupling (Nylon tarpaulin)
(Plate fan)Air volume: 31 m3/min, Static pressure: 1.75 kPaMotor: 3.7 kW, 4P, 50 Hz� Casing: Inner surface treated by wear-resistant thermal spraying. A
chromium-based alloy is sprayed to a thickness of 0.1 mm.� Impeller: Treated by wear-resistant thermal spraying.
A hard build-up welding rod based on tungsten carbide is used on the �ow region.� Intake port: Totally removable construction� The casing and the bearing pedestal are of separable construction to allow
replacement of the casing.
(Axial-�ow fan)Air volume: 400 m3/min, Static pressure: 0.50 kPaMotor: 11 kW, 4P, 60 Hz� Material: SUS304 for impeller, shaft, and gas contact region� Intake air temperature: 300 deg (maximum)� Impeller diameter: 740 mm� Bearing: Air-cooled type� Others: This fan is of furnace ceiling-mounted construction with its impeller
facing downward.
(Turbo fan)Air volume: 30 m3/min, Static pressure: 2.94 kPaMotor: 3.7 kW, 2P, 60 Hz� Materials: SUS304 for gas contact region and Te�on-coating for casing and
intake port� Shaft seal: Te�on sheet packing� Others: The casing and the bearing case are of separable bolted construction
to allow independent replacement of the casing.
� Material: Stainless steel� Applications: Agitating the inside of a drying furnace for a uniform
temperature distribution� Intake air temperature: 150 deg (maximum)� Impeller diameter: 630 mm� Others: Directly connected to motor
Temperature Conversion Shaft Seal
Optional Shaft Seals
31 32
Technical Information/Data 1 Technical Information/Data 2Technical Inform
ation/Data
Precautions for selection Showa Denki's standard shaft seals
Packing seals (For fans/blowers: Iga Factory products)
Mechanical seal (Contact seal)
P1 = Speci�ed static pressure at a gas temperature "t" of 1°C
P2 = Speci�ed static pressure at a gas temperature "t" of 2°C
L1 = Speci�ed shaft power at a gas temperature "t" of 1°C
L2 = Speci�ed shaft power at a gas temperature "t" of 2°C
Air volume: Q2 = Invariant (m3/min)
List of temperature conversion coefficients
Static pressure: P2 = P1 × (kPa)273+t2
273+t1
Shaft power: L2 = L1 × (kW)273+t2
273+t1
Temp (°C) Coe�cient Temp (°C) Coe�cient Temp (°C) Coe�cient Temp (°C) Coe�cient
Kind of seal Types of fan/blowers
0102030405060708090
100110120130140150160170180190
200210220230240250260270280290300310320330340350360370380390
400410420430440450460470480490500510520530540550560570580590
600610620630640650
0.930.971.001.031.070.101.141.171.201.241.271.311.341.381.411.441.481.511.551.58
1.611.651.681.721.751.781.821.851.891.921.961.992.022.062.092.132.162.192.232.26
2.302.332.372.402.432.472.502.542.572.602.642.672.712.742.772.812.842.882.912.95
2.983.013.053.083.123.15
Glass clothLow-pressure and middle-pressure turbofans/plate fans
Floating sheet
Fan/blower shaft
Casing interior
Casing interior
Packing seal
Fan/blower shaft
Outside Inside B
d2 d d3
B1d2 : Maximum diameterd3 : Minimum diameter
d1
Seal ring
Coil spring
This seal conducts sealing on two planes perpendicular or almost perpendicular to the fan/blower shaft. One of the planes is used as a rotary plane, and the other is used as a stationary plane. Packings are also referred to as edge seals, and of these seals, shaft-sealing devices having a buffer mechanism to maintain the to-be-sealed planes in an appropriate contact status are referred to as mechanical seals.Advantage: - Virtually no leakageDisadvantages: - Complex in structure, and expensive. - Difficult to replace.
Labyrinth seal (Non-contact seal)
This seal forms very small clearances between a rotor and a stator. The gas usually leaks and decreases in pressure while the flow of the gas alternates between the relatively wide clearances and relatively narrow ones of the formed clearances. The seal utilizes the event.This type of seal is used in the cases that the surface velocity of the fan/blower shaft exceeds 12 m/s and that a slight amount of gas leakage from the casing is allowed.Advantages: - No sections suffer wear because of non-contact. - Easily responsive to thermal expansion.Disadvantages: - Sealing performance during slow rotation and
under a stopped state is relatively low.
V-rings (For electric blowers: Daito Factory products)
The V-ring, made from 100% homogeneous rubber, has its ribs and body coupled via hinges.The V-ring is mounted for sealing against dust and moisture, and this ring is provided as a standard component in virtually all middle-size and larger electric fans and blowers manufactured at the Daito Factory.
Heat-resistant type
Intake Air Temperatures and the Types of BearingsIntake air
temp
Bearing type
Above -10°C, but up to 50°C
Standard Heat-resistant Heat-resistant (Air-cooled) Heat-resistant (Water-cooled)
Standard grease Heat-resistant grease Heat-resistant grease Heat-resistant greaseStandard (2.5Y6/2) Heat-resistant silver (Standard for up to 80°C)
Munsell 2.5YR 6/13
Heat-resistant silver Heat-resistant silver
Above 50°C, but up to 150°C
Above 150°C, but up to 350°C
Above 350°C, but up to 650°CDepends on model and speed
Construction
LubricationFan/blower coatingGuards coating
Shaft seal Shaft sealShaft seal
Cooling fan Cooling fan
Water-cooling metal
Shaft seal
The fan/blower performance curve sheets in the catalog are based on a standard state of 20˚C. Even for identical fans/blowers, when the temperature of the gas being to be handled changes, specified points (design criteria) will change as follows per the following calculation expressions:
� The shaft seal refers to that of the region at which the fan/blower penetrates the casing. The shaft-sealing device is needed to prevent the gas inside the casing from leaking from the shaft seal, or to prevent the atmosphere from flowing from the shaft seal into the casing.
� If the kind of gas to be handled is standard air and the static pressure is up to nearly 1 kPa, there is no need to provide the shaft-sealing device. In general, packings and/or labyrinth seals are used in fans.
Notes: Air changes in volume according to temperature and pressure, and will expand when the temperature rises. When air expands, mass will decrease even if the volume remains the same.However, since the air volume, as expressed in terms of m3/min or m3/h, is a volumetric flow rate that represents the volume per unit time, the air volume will remain invariant, even when the temperature rises.
Technical Information/D
ata
T1,T2V40
Details of impeller mounting �xture
2524
Details of impeller mounting �xture
T1,T2V08 to 10
22
21
23
2018 191716
15
14
1312111098
7654321
14
1211
7
6
5
3
2
1
13
8
9
4
10
16
15
1413121110987
6
5
4
3
2
1
Construction of Fans and Blowers Energy-saving Effects of Reducing the Fan/Blower Speed by 10%
Storage of the Fan/Blower
Roller Ball Dropping Sound
33 34
Technical Information/Data 3 Technical Information/Data 4
If the fan/blower is stored or shut down with the rotating shaft of the impeller remaining stopped for at least about three months in succession, contact sections between the balls of the bearing and the track surface may suffer oil film breakage, depending on the season or the environment. If this is the case, unusual sounds will result from unwanted events such as corrosion.Remove the bearing guard periodically (at least once a month) and manually rotate the shaft through about 10 turns to prevent bearing corrosion.
Precautions for storage
The roller ball dropping sound of the fan bearing features the following
� V-belt drive
� Tapered shaft/holes adopted for fan/blower mounting fixtures
� Directly connected to coupling
� Denchoku standards
(1) Store your product at a dry location with minimum changes in indoor temperature.(2) Shroud your product with waterproof sheeting to protect the product from moisture, oils, dust, and the like.(3) Avoid storage in a place exposed to direct sunlight, strong vibration or heat, and the like. Also, avoid contact with a cold
wall.
(1) Upon moving from a non-loaded area into a loaded area, the roller becomes free to move and the balls start to roll by gravity, thus hitting the retainer to generate the sound.
(2) The magnitude of the sound varies from product to product.(3) The sound level increases and decreases.
(1) The internal clearances of the heat-resistant bearings and other bearings of the B2V and B3V blowers which rotate at high speed are preset to be C3 clearances allowing for expansion due to bearing temperature rises to at least about 150˚C.
(2) Since the C3 clearances are large in comparison with CN clearances, the roller ball dropping sound may occur under relatively low bearing temperatures.
Bearing clearances
Storage location
6
5
4
3
2
1
0
240
200
160
120
8099
72
40
00 500 1000
10801200
20001500 2500
(kPa)
Static pressure
Shaft power
(BkW) � Fan/blower speed
1120 min-1
1012 min-1
10% down
� System air volume
1200 m3/min
1080 m3/min
10% down
� Shaft power
Air volume (m³/min)
99 kW
72 kW
27% downPart No.
123456789
10111213141516171819202122232425
Qty111121
2 sets1 set
121111111111111
1 set1
Intake portImpellerCasingBearingBearing housing bodyBearingBearing housing coverCasing shaft sealShaftPillow-type unitBearing guardBelt guardParallel key for V-pulleyHolder for V-pulleyBolt for holderHub-locking nutLock washerImpeller hubParallel key for impellerCommon baseV-pulleyBolt for holderHolder for impellerHexagon socket setscrewHolder for impeller
Part NameLow-carbon steelLow-carbon steelLow-carbon steel
FC200
FC200Non-asbestosS45C
Low-carbon steelLow-carbon steelS45CLow-carbon steelLow-carbon steelLow-carbon steelLow-carbon steelFC200S45CLow-carbon steelFC200Low-carbon steelLow-carbon steelSCM435FC200
Material
Part No.123
456789
10111213141516
Qty111
121211111
1 set111
CasingIntake portImpeller
Parallel keyHolder setboltHolderShaft sealCounter-drive bearingShaftDrive bearingBearing guardCoupling guardCouplingMotorBearing/motor baseBase
Part NameLow-carbon steelLow-carbon steelLow-carbon steel, High-strength steelS45CLow-carbon steelFC200Non-asbestos
S45C
Low-carbon steelLow-carbon steel
Low-carbon steelLow-carbon steel
Material
Part No.12345678
91011121314
Qty11111111
1 set11111
CasingImpellerIntake portIntake case �angeParallel keyHolderHolder setboltMotor
PackingOutlet case �angeShaft sealShaft seal clampShaft guardMotor base
Part NameLow-carbon steelLow-carbon steelLow-carbon steelLow-carbon steelS45CLow-carbon steelLow-carbon steelMotor manufacturer's standards
Low-carbon steelNon-asbestosLow-carbon steelLow-carbon steelLow-carbon steel
Material
Impeller hub
Parallel key
Hex socket setscrew
Shaft-locking nut
Lock washer
* Maintainability signi�cantly improves.
Shaft
Advantages(1) Saves impeller mounting/dismounting time.(2) High-temperature specifications: Any effects of thermal distortion on hub holes
and shaft are minimized.(3) Stainless steel specifications: Hub hole/shaft fusion (scuffing) can be prevented.
Applicable modelsT1/T2-12 to 36 Cantilever type, Belt-driven type, Coupling-driven typeB2-04 to 10, B3-05 to 10 Cantilever type, Belt-driven type, Coupling-driven typeM1-14 to 32 Cantilever type, Belt-driven type, Coupling-driven typeKT-30 to 90 Cantilever type, Belt-driven type, Coupling-driven type
Quadratic system loss curveDecreases in air volume reduce pressure loss in proportion to the square of the air volume.