PU00430 ACCESS CONTROL 09 ING - Fermax-servis.cz · din rain model receiver single channel receiver...
Transcript of PU00430 ACCESS CONTROL 09 ING - Fermax-servis.cz · din rain model receiver single channel receiver...
ACCESS CONTROL
WARRANTYAll Fermax products have a 24 months warranty.
Fermax«obligation under this warrany, however, isexpressly limited (at Fermax«option) to replacing,repairing, or issuing credit for any product returnedto FERMAX within twenty four (24) months from dateof shipment by FERMAX and then only if: (a) thedefective product is returned to FERMAX, transportcharges prepaid, (b) examination of the productdiscloses to FERMAX«satisfaction that defects in theproduct have not been caused by misuse, neglect,improper installation, repair alteration or accidentand (c ) re turned mater ia l must at tach theAuthorization for return form.
This warranty does not cover problems arising duecauses with equipment (for example deficiencies ininstallation or incorrect wiring), nor breakdownscaused by incorrect manipulat ion of blows.
LIMIT OF LIABILITYIt is expressly understood and agreed that FERMAXis not an insurer that the products or services soldhereunder will perform functions or prevent: thatFERMAX shall be exempt from liability for all loss ordamage therefrom; and that insurance, if any, shallbe obtained by the Distributor.
Liabil ity shall be l imited to an amount to theconsideration paid by the distributor for such productsor services as the distributor exclusive remedy.
DELIVERY15 days after order confirmation and reception ofpayment.Allow 30 days for special orders.Every endeavour will be made by the Company toadhere to the delivery dates quoted, but such datesare only estimate and are not guaranteed neither shallthey be a term of condition between the Buyer andthe Company.The Buyer shall be responsible for arranging insuranceon goods col lected by the i r own carr iers .Delay in delivery shall by no means entitle the Buyerto cancel the order or thereby render the Seller liableto the Buyer for any loss or expense arising from thede lay un less otherwise agreed in wr i t ing .Ex works. ˚
OWNIRSHIP OF GOODSThe goods shall remain the property of the Seller untilpaid for in full by the Buyer.
CANCELLATIONCancellation of any order or goods or any part of anorder will not be valid after the Buyer has placed theorder unlessthe cancellation is accepted by the Sellerin writing.
Dear partner,
This fourth edition of the Access Control catalogue takes in the complete range of FERMAX solutions foraccess restriction.
You can choose the most suitable option according to the specific needs and features of the installation:
• Styling: for interiors, outdoors or vandal-proof version.• Reader technology: keypad, proximity, radio frequency, fingerprint and Bluetooth.• System: Stand-alone (1 access), stand-alone in network (32 accesses) and centralized (large installations).
This new document has been designed to provide you with detailed and structured information on all theoptions, in technical f i le format, for easy understanding and use by the professional.
The main new features that you will find in this edition are:
• Stand-alone system.
The Bluetooth Kit lets you open the door with a mobile phone. It is a technological and innovating product.City Fingerprint Reader. Cutting-edge technology now at a highly competitive price. Includes thermal readertechnology, recommended in exteriors. Storage capacity: 950 fingerprints.Marine Readers for exteriors made in stainless steel, now available in keypad version (Memokey) and proximity(Private).New RF remote control l ine with an exclusive design and more robust mechanics.
We emphasize the versatility offered by our access control range for integration in any video entry systempanel. Ask for the modular format of the desired reader and integrate it in an outdoor panel.
• Stand-alone system in network. Recommended for average size applications - up to 32 accesses and 1000users. Management handled from intuitive and practical PC software. An interesting balance between benefitsand simplicity in system management and start-up.
• Centralized system. The new software that comes as standard with the Central Unit also includes managementof user authorizations/cancellations and access permits/restrictions and now also time & attendance softwarefor staff clock-in management and calculation of hours worked (for pays management).
You can also find all updated information on our products in the product section of our website www.fermax.com.
Thank you for your confidence.
Jeremy PalacioAccess Control Product Manager
S t a n d - a l o n e 1 1
S t a n d - a l o n e i n n e two r k 3 7
C e n t r a l i z e d 4 9
A c c e s s o r i e s 7 5
C o n t e n t G u i d e
Keypad
Proximity
Bruto
Description
Bruto ModuleCitymax Module
City Bruto Loft
3610
3600
4480
23291
ref.
4500
2 1 3 3
-
2553
ref.
4540
3623
45504550+4420
ref.
STAND-ALONE
STAND-ALONE KIT
STAND-ALONE IN NETWORK
CENTRALIZED
Description
Citymax Module Bruto Module Marine
Description
2347
2260
4490
23351or
4490+4420
ref.
4520
-
4510
2552or
4510+4420
ref.Description
4530
3624
4560
ref.
4560+4420
4698
-
-
-
ref.
Marine
QUICK GUIDE
STAND-ALONE
STAND-ALONE KIT
STAND-ALONE IN NETWORK
CENTRALIZED
STAND-ALONE
STAND-ALONE KIT
STAND-ALONE IN NETWORK
CENTRALIZED
STAND-ALONE
STAND-ALONE KIT
STAND-ALONE IN NETWORK
CENTRALIZED
06
City Loft
-
-
2263
2560
ref.
-
-
2288
2268
ref.
2520
-
-
2561
ref.
2523
-
-
22371
ref.
4699
-
-
-
ref.
BluetoothTM
BluetoothTM
STAND-ALONE
STAND-ALONE KIT
STAND-ALONE IN NETWORK
CENTRALIZED
Description
PCB Module
7900
-
-
-
ref.
Key button
STAND-ALONE
STAND-ALONE KIT
STAND-ALONE IN NETWORK
CENTRALIZED
Description
City
or2315+4420
-
-
2315
23261
ref.
Bruto
-
-
-
2554
ref.
Bluetooth
City
Description
4477
4478
-
-
ref.
4476
-
-
-
ref.
Citymax Module
Fingerprint
Optical Reader
-
-
-4470+4420
ref.
STAND-ALONE
STAND-ALONE KIT
STAND-ALONE IN NETWORK
CENTRALIZED
Description
City
6989
-
69896989+4420
ref.
Citymax Module
QUICK GUIDE
STAND-ALONE
STAND-ALONE KIT
STAND-ALONE IN NETWORK
CENTRALIZED
07
Radio frequency
Box Receiver DIN Rail MDS Single Channel Receiver
MDS SecondaryReceiver
7960
7912
-
-
ref.
7903
7910
-
-
ref.
7952
7911
-
1065
ref.
-
-
-
2464
ref.
6990
6988
69906990+4420
ref.
08
Accessories - Common to all the access control systems.
Stand-alone - The easiest access control to install. No PC required.An ideal access control solution for indoors and outdoors, to manage a single access or door in the most practical and
simple way. Swift and easy to install: only two power supply cables. Reader technologies available are keypad, proximity
readers, radio frequency systems, Bluetooth technology and digital fingerprint.
Stand-alone in network - Secure and practical access control. PC required.The stand-alone access control system in network is recommended when you want to manage permits/restrictions for
up to 32 accesses or doors from a PC. The on–line events record enables a fast graphic view of incoming and outgoing
user flow.
Centralized - The most complete and versatile solution. PC Required.Enables complete management of an installation with multiple accesses (up to 2048) and advanced access control
functions. There are two systems: MDS and CAC. MDS is recommended in installations with audio or video door entry
systems and access control functions, alarms and automation. CAC is the best option for purely access control
installations thanks to its new functions: vehicle control and time & attendance for salary management. Also includes
alarms management and automation.
*(0)
Re f e rence char t / i n dex
09
CITY
CITYMAX MODULE
BRUTO
BRUTO MODULE
LOFT
MARINE
3610
2520
4500
2523
4540
4699
4480
-
-
-
4550
-
23291
2561
2553
22371
4550*(1)+4420
-
KEYPAD
PROXIMITY
CITY
CITYMAX MODULE
BRUTO
BRUTO MODULE
LOFT
MARINE
2347
2263
4520
2288
4530
4698
4490
-
4510
-
4560
-
23351 o 4490+4420
2560
2552 o 4510+4420
2268
4560+4420
-
KEY BUTTON
CITY
CITYMAX MODULE
BRUTO
BRUTO MODULE
-
-
-
-
2315
-
-
-
23261 o 2315+4420
-
2554
-
RADIOFREQUENCY
PCB MODULE RECEIVER
BOX RECEIVER
DIN RAIN MODEL RECEIVER
SINGLE CHANNEL RECEIVER
MDS SECUNDARY RECEIVER
7900
7960
7903
7952
-
-
-
-
-
-
-
-
-
1065
2464
BLUETOOTH
CITY
CITYMAX MODULE
4477
4476
-
-
-
-
FINGERPRINT
A
N
-
6990
6989
-
6990
6989
4470+4420
6990+4420
6989+4420
STAND-ALONE STAND-ALONEIN NETWORK
CENTRALIZED(MDS and CAC)
R E F E R E N C E SREADER
OPTICAL READER
CITY
NOTE: The symbol “-” indicates that there is no such combination. *(0) Ref.4480 is a keypad and proximity reader. *(1) Ref.4550 is a keypad
and proximity reader.
*(1)
CITYMAX MODULE
Simple access control system managing one access.
S t a n d - a l o n e a c c e s s c o n t r o l
Memokeystand-alone
1 2 3
4 5 6
7 8 9
A 0 B
ST
AN
D-A
LO
NE
Specifications Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):
12V (ac/dc) 6/602A (NA,NC)
0 to 70ºC
130x128x18115x114x45130x128x33
4307
Power supply (V):Consumption (mA) without door release:Relay Contact:
Operating temperature:Programmable from 01 to 99 sec. or bistable
Exit pushbutton and free access button input.
Electric lock activation by relay. With auxiliary relay for other
functions.
Programmable relay times (monostable, bistable).
Each code can activate one or two relays simultaneously.
Multi-function OC output: coercion alarm, wrong code or
tamper.
Technical features
Installation Keypad is located in the outside zone. The rest of the
devices, installed indoors, are connected to it: power supply
and electric lock. Optionally, an exit pushbutton can be
used if there is no door handle (LOFT model) to detect if
the door remains open.
Programming from the keypad by Master code.Programming
Access control keypad with capacity for up to100 different of 4 to 6-digit codes.Manufactured in aluminium.Flush or surface mounted ( ref .8851).Recommended for interiors and exteriors.Reader and controller in the same module(ref.3610) or separate (ref.3620 and ref.3621).
City Memokey (ref.3610)
12 Available in kit (ref.3600)
Power supply
Ref.3610
Door release
Exitbutton
2
2
230Vac
2
13
Memokeystand-alone
1 2 3
4 5 6
7 8 9
A 0 B
ST
AN
D-A
LO
NE
Memokey City CR (ref.3620) Memokey controller CR (ref.3621)
Specifications Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Metallic box (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):
12V (ac/dc) 6/602A (NA,NC)
0 to 70ºC
130x128x18115x114x45130x128x33154x203x50
4307
Power supply (V):Consumption (mA) without door release:Relay contact:
Operating temperature:Programmable from 01 to 99 sec. or bistable
Technical features
Installation The CR keypad is located on the outside, connected to the
controller situated in the interior, the same as the rest of
the devices: power supply and electric lock. Optionally, an
exit pushbutton can be used (if there is no door handle)
and a second CR keypad on the inside.
Programming from keypad by Master code.Programming
Reader (ref.3620) and controller (ref.3621) in twostand-alone modules for enhanced security.The controller is installed indoors next to the powersupply and door release. Metallic box included with controller (measurements:154x203x50mm).A second CR keypad can be added on the inside.Maximum distance: 100 meters.
City Memokey CR (ref.3620+3621)
Available in kit (ref.3591)
Exitbutton
22
Power supply
2
230Vac
6
Exit pushbutton and free access button input.
Electric lock activation by relay. With auxiliary relay for other
fuctions.
Programmable relay times (monostable, bistable).
Each code can activate one or two relays simultaneously.
Multi-function OC output: coercion alarm, wrong code or
tamper.
Electric lock unblocking by code (free access).
2
Door release
Ref.3620
Ref.3621
Memokeystand-alone
Exitbutton
2
1 2 3
4 5 6
7 8 9
A 0 B
Power supply
Ref.2520
Door release
2
230Vac
2
ST
AN
D-A
LO
NE
City Memokey Module (ref.2520)
Access control keypad with capacity for up to 100different 4 to 6-digit codes.Manufactured in aluminium.To be fitted in CityMax audio or video door entrysystem outdoor panels to improve home security.Reader and controller integrated in the samemodule (ref.2520).
Specifications Environmental protection (IP):Protection against knocks (IK):Power supply (V):Consumption (mA) without door release:Relay contact:Programmable from 01 to 99 sec. or bistableOperating temperature:
4307
12V (ac/dc)6/60
2A (NA,NC)
0 to 70ºC
Installation Audio or video door entry panel located in the outside
area. It is possible to set up the panel intuitively to
include a keypad (ref.2520) for greater security and more
convenient access.
Programming from keypad by Master code.Programming
14
Technical features Exit pushbutton and free access button input.
Electric lock activation by relay. With auxiliary relay for
other functions.
Programmable relay times (monostable, bistable).
Each code can activate one or two relays simultaneously.
Open collector auxiliary output (150mA max) to indicate
sabotage attempt or door open/forced.
Electric lock unblocking by code (free access).
15
Memokeystand-alone
1 2 3 A
654 0
B987
Power supply
Ref.4500
Door release
Exitbutton
2
2
230Vac
2
Exit pushbutton and free access button input.
Electric lock activation by relay. With auxiliary relay for other
functions.
Programmable relay times (monostable, bistable).
Each code can activate one or two relays simultaneously.
Multi-function OC output: coercion alarm, wrong code or
tamper.
Technical features
ST
AN
D-A
LO
NE
Specifications Dimensions (WxHxDmm):Flush box (included):Surface box(WxHxDmm):Environmental protection (IP):Protection against knocks (IK):
12V (ac/dc) 6/602A (NA,NC)
0 to 70ºC
135x130x18115x100x45135x131x42
5309
Power supply (V):Consumption (mA) without door release:Relay contact:
Operating temperature: Programmable from 01 to 99 sec. or bistable
Installation Keypad is located in the outside zone. The rest of the devices,
installed indoors, are connected to it: power supply and
electric lock. Optionally, an exit pushbutton can be used if
there is no door handle (LOFT model) to detect if the door
remains open.
Programming from keypad by Master code.Programmation
Access control keypad with capacity for up to 100different 4 a 6-digit codes.Vandal-proof panel.Flush or surface mounted (ref.2778).Recommended for interiors and exteriors.Reader and controller integrated in the same module.Ideal for troubled zones or districts, offices, banks,etc.
Bruto Memokey (ref.4500)
Available in kit (ref.2133)
Memokeystand-alone
Exit pushbutton and free access button input.
Electric lock activation by relay. With auxiliary relay for
other functions.
Programmable relay times (monostable, bistable).
Each code can activate one or two relays simultaneously.
Multi-function OC output: coercion alarm, wrong code or
tamper.
Technical features
ST
AN
D-A
LO
NE
Programming from keypad by Master code.
Access control keypad with capacity for up to 100different 4- to 6-digit codes.Vandal-proof keypad.To be fitted in Bruto audio or video door entry panelviewers for enhanced security in the home.Reader and controller integrated in the same module(ref.2523).
Bruto Memokey Module (ref.2523)
Specifications Environmental protection (IP):Protection against knocks (IK):Power supply (V):Consumption (mA) without door release:Relay contact:Programable from 01 to 99 sec. or bistableOperating temperature:
5309
12V (ac/dc)6/60
2A (NA,NC)
0 to 70ºC
16
Exitbutton
2
Power supply
Ref.2523Door release
2
230Vac
2
Keypad is located in the outside zone. The rest of the
devices, installed indoors, are connected to it: power
supply and electric lock. Optionally, an exit pushbutton
can be used if there is no door handle (LOFT model) to
detect if the door remains open.
Installation
Programmation
Power supply
Ref.4540
Door release
Exitbutton
2
2
230Vac
2
2
1 2 3
4 5 6
7 8 9
A 0 B
Availalble in kit (ref.3623) 17
Memokeystand-alone
Exit pushbutton and free access button input.
Electric lock activation by relay.
Multi-function OC output: coercion alarm, wrong code and
forced door.
Electric lock unblocking by code (free access).
Status LEDs: door open/closed/power supply.
Technical features
ST
AN
D-A
LO
NE
Specifications Dimensions (WxHxDmm):Flush box:Superface box (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):
12V (ac/dc) 20/70 2A (NA,NC) 0 to 70ºC
60x130x23 Not required Not required
6606
Power supply (V):Consumption (mA) without door release:Relay contact:Operating temperature:
Keypad is located in the outside zone. The rest of the devices,installed indoors, are connected to it: power supply andelectric lock. Optionally, an exit pushbutton can be used ifthere is no door handle (LOFT model) to detect if the doorremains open.
Programming from keypad by Master code.
Access control keypad with capacity for up to 100different 4 to 6-digit codes.Manufactured in ABS plastic.Surface mounted.Recommended for interiors.Reader and controller integrated in the same moduleIdeal for screen profiles in offices.Includes a 50cm cable.
Loft Memokey (ref.4540)
Installation
Programmation
Power supply
Ref.4699
Door release
Exitbutton
2
2
230Vac
2 1 2 3
A
654
0 B
987
Memokeystand-alone
Exit pushbutton and free access button input.
Electric lock activation by relay. With auxiliary relay for
other functions.
Programmable relay times (monostable, bistable).
Each code can activate one or two relays simultaneously.
Multi-function OC output: coercion alarm, wrong code
or tamper.
Technical features
ST
AN
D-A
LO
NE
Specifications
Keypad is located in the outside zone. The rest of thedevices, installed indoors, are connected to it: powersupply and electric lock. Optionally, an exit pushbuttoncan be used if there is no door handle (LOFT model) todetect if the door remains open.
Programming from keypad by Master code.
Marine Memokey (ref.4699)
18
Access control keypad with capacity for up to 100different 4- to 6-digit codes.Stainless steel panel 2.5mm thickness.Keypad with 4x3 layout and orange backlight.Flush or surface mounted (ref.4645).Recommended for interiors and exteriors.Reader and controller integrated in the samemodule.
Installation
Programmation
Dimensions (WxHxDmm):Flush box (included):Superface box (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):
12V (ac/dc) 6/602A (NA,NC).
0 to 60ºC
153x123x50130x160x55154x184x73
5309
Power supply (V):Consumption (mA) without door release:Relay contact:
Operating temperature:Programmable from 01 to 99 sec. or bistable
Privatestand-alone
19Available in kit (ref.2260)
( restricted area )
PRIVATE ACCESS CONTROL
Technical features
ST
AN
D-A
LO
NE
Specifications
Exit pushbutton and free access button input.
Electric lock activation by relay with programmable timing.
Programming help LEDs.
Keypad is located in the outside zone. The rest of thedevices, installed indoors, are connected to it: power supplyand electric lock. Optionally, an exit pushbutton can beused if there is no door handle (LOFT model) to detect if thedoor remains open.
City Private (ref.2347)Proximity card reader with capacity for up to 400users.Manufactured in aluminium.Flush or surface mounted (ref.8851).Recommended for interiors and exteriors.Reader and controller integrated in the same module.
Can be done in 3 ways:
Master card: The first time that the power supply
is connected, the system waits for a proximity card
which will be considered as “master card”.
Keypad: Recommended if we want to cancel lost
cards (ref. 2306).
PC software: The most convenient solution for
authorization and cancellation management (ref.2351).
Identifiers ref.23361 ref.2336 ref.2336 ref.2364 ref.44501
Withoutpersonalizing and
with magnetic strip.
Customizable(photo, name,company...)
For replacementwith magnetic
strip.
Withoutpersonalizing
or magnetic strip.
Proximitykeyring.
Installation
Programmation
Dimensions (WxHxDmm):Flush box (included):Superface box (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):Power supply (V):Cons. (mA) without door release:
2A (NA,NC).
0 to 60ºC
6/5 cmRS-232
130x128x18115x114x45130x128x33
4307
12V (ac/dc) 80/120
Relay contact:
Operating temperature:Reading distance(card/keyring):IP Interface:
Programmable from 01 to 99 sec. or bistable
Power supply
Ref.2347
Door release
Exitbutton
2
2
230Vac
2
2
Privatestand-alone
( restricted area )
PRIVATE ACCESS CONTROL
Power supply
Ref.2263Door release
Exitbutton
2
230Vac
2
2
2
Technical features
ST
AN
D-A
LO
NE
Proximity card reader with capacity for up to 400users.To be fitted in the viewer of CityMax audio or videodoor entry panels for enhanced security in the home.Reader and controller integrated in the same module.
City Private Module (ref.2263)
Exit pushbutton and free access button input.
Electric lock activation by relay with programmable timing.
Programming help LEDs.
The audio or video door entry panel is located in the outside
area. It is possible to set up the panel intuitively to include
a keypad (ref.2263) for greater security and more convenient
access.
Environmental protection(IP):Protection against knocks (IK):Power supply (V):Cons. (mA) withot door release:Relay contact:
0 to 60ºC
6/5 cmRS-232
4307
12V (ac/dc)80/120
2A (NA,NC).
Operating temperature:Reading distance(card/lkeyring):PC Interface:
ref.23361 ref.2336 ref.2336 ref.2364 ref.44501
Withoutpersonalizing and
with magnetic strip.
Customizable(photo, name,company...)
For replacementwith magnetic
strip.
Withoutpersonalizing
or magnetic strip.
Proximitykeyring.
20
Specifications
Identifiers
Installation
Programmation Can be done in 3 ways:
Master card: The first time that the power supply
is connected, the system waits for a proximity card
which will be considered as “master card”.
Keypad: Recommended if we want to cancel lost
cards (ref. 2306).
PC software: The most convenient solution for
authorization and cancellation management (ref.2351).
21
Privatestand-alone
2
( restricted area )
PRIVATE ACCESS CONTROL
Power supply
Ref.4520
Door release
Exitbutton
2
230Vac
2
2
Technical features
ST
AN
D-A
LO
NE
Proximity card reader with capacity for up to 400users.Vandal-proof reader.To be fitted in the viewer of the Bruto audio or videodoor entry panels for enhanced security in the home.Reader and controller integrated in the same module.
Private Bruto (ref.4520)
Exit pushbutton and free access button input.
Electric lock activation by relay with programmable timing.
Programming help LEDs.
Keypad is located in the outside zone. The rest of thedevices, installed indoors, are connected to it: power supplyand electric lock. Optionally, an exit pushbutton can beused if there is no door handle (LOFT model) to detect ifthe door remains open.
Dimensions (WxHxDmm):Flush box (included):Superface box (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):Power supply (V):Comsumption (mA) door release
2A (NA,NC).
0 to 60ºC
4/2 cmRS-232
135x130x18115x100x45135x131x42
5309
12V (ac/dc)80/120
Relay contact
Operating temperatureReading distance:(card/keyring):PC Interface:
Programmable from 01 to 99 sec. or bistable
Can be done in 3 ways:
Master card: The first time that the power supply
is connected, the system waits for a proximity card
which will be considered as “master card”.
Keypad: Recommended if we want to cancel lost
cards (ref. 2306).
PC software: The most convenient solution for
authorization and cancellation management (ref.2351).
Specifications
Identifiers
Installation
Programmation
ref.23361 ref.2336 ref.2336 ref.2364 ref.44501
Withoutpersonalizing and
with magnetic strip.
Customizable(photo, name,company...)
For replacementwith magnetic
strip.
Withoutpersonalizing
or magnetic strip.
Proximitykeyring.
Privatestand-alone
Technical features
ST
AN
D-A
LO
NE
Proximity card reader with capacity for up to 400users.Vandal-proof reader.To be fitted in the viewer of the Bruto audio or videodoor entry panels for enhanced security in the home.Reader and controller integrated in the same module.
Bruto Private Module (ref.2288)
Can be done in 3 ways:
Master card: The first time that the power supply
is connected, the system waits for a proximity card
which wil l be considered as master card.
Keypad: Recommended if we want to cancel lost
cards.
PC software: The most convenient solution for
authorization and cancellation management (ref.2351).
Environmental protection (IP):Protection against knocks (IK):Power supply (V):Consumption (mA) without door release:Relay contact:Programmable from 01 to 99 sec. or bistableOperating temperature:
5309
12V (ac/dc)80/120
2A (NA,NC)
0 to 70ºC
Exit pushbutton and free access button input.
Electric lock activation by relay with programmable timing.
Programming help LEDs.
22
Keypad is located in the outside zone. The rest of the devices,installed indoors, are connected to it: power supply andelectric lock. Optionally, an exit pushbutton can be used ifthere is no door handle (LOFT model) to detect if the doorremains open.
2
Exitbutton
( restricted area )
PRIVATE ACCESS CONTROL
Specifications
Identifications
Installation
Programmation
ref.23361 ref.2336 ref.2363 ref.2364 ref.44501
Withoutpersonalizing and
with magnetic strip.
Customizable(photo, name,company...)
For replacementwith magnetic
strip.
Withoutpersonalizing
or magnetic strip.
Proximitykeyring.
Power supply
Ref.2288
Door release
2
230Vac
2
2
Available in kit (ref.3624) 23
Privatestand-alone
Loft Private (ref.4530)Access control keypad with capacity for up to 100different 4 to 6-digit codes.Manufactured in ABS plastic.Surface mounted.Recommended for interiors.Reader and controller integrated in the same moduleIdeal for screen profiles in offices.Includes a 50cm cable .
Technical features
ST
AN
D-A
LO
NE
Exit pushbutton and free access button input.
Electric lock activation by relay with programmable timing.
Programming help LEDs.
Keypad is located in the outside zone. The rest of thedevices, installed indoors, are connected to it: power supplyand electric lock. Optionally, an exit pushbutton can beused if there is no door handle (LOFT model) to detect ifthe door remains open.
Dimensions (WxHxDmm):Flush box (included):Superface box (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):Power supply (V):
45/752A (NA,NC).
0 to 60ºC
8/6 cmRS-485
60x130x23Not requiredNot required
6606
12V (ac/dc)
Cons. (mA) without door release:Relay contact:Operating temperature:Reading distance(card/keyring):PC Interface:
2
Specifications
Identifiers
Installation
Programmation Can be done in 3 ways:
Master card: The first time that the power supply
is connected, the system waits for a proximity card
which will be considered as master card.
Keypad: Recommended if we want to cancel lost
cards (ref. 2306).
PC software: The most convenient solution for
authorization and cancellation management (ref.3625)
ref.23361 ref.2336 ref.2336 ref.2364 ref.44501
Withoutpersonalizing and
with magnetic strip.
Customizable(photo, name,company...)
For replacementwith magnetic
strip.
Withoutpersonalizing
or magnetic strip.
Proximitykeyring.
Power supply
Ref.4530
Door release
Exitbutton
2
230Vac
2
2
Privatestand-alone
2
Exitbutton
( restricted area )
PRIVATE ACCESS CONTROL
Power supply
Ref.4698
Door release
2
230Vac
2
2
Technical features
ST
AN
D-A
LO
NE
Proximity card reader with capacity for up to 400users.Stainless steel panel 2.5mm thickness.Flush or surface mounted (ref.4645).Recommended for interiors and exteriors.Reader and controller integrated in the same module.
Marine Private (ref.4698)
Keypad is located in the outside zone. The rest of thedevices, installed indoors, are connected to it: power supplyand electric lock. Optionally, an exit pushbutton can beused if there is no door handle (LOFT model) to detect ifthe door remains open.
Exit pushbutton and free access button input.
Electric lock activation by relay with programmable timing.
Programming help LEDs.
24
Specifications
Identifiers
Installation
Programmation
ref.23361 ref.2336 ref.2336 ref.2364 ref.44501
Withoutpersonalizing and
with magnetic strip.
Customizable(photo, name,company...)
For replacementwith magnetic
strip.
Withoutpersonalizing
or magnetic strip.
Proximitykeyring.
Can be done in 3 ways:
Master card: The first time that the power supply
is connected, the system waits for a proximity card.
which will be considered as master card.
Keypad: Recommended if we want to cancel lost
cards (ref.1306).
PC software: The most convenient solution for
authorization and cancellation management (ref.2351)
Dimensions (WxHxDmm):Flush box (included):Superface box (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):Power supply (V):
80/1202A (NA,NC).
0 to 60ºC
6/5 cmRS-232
153x123x50130x160x55154x184x73
5309
12V (ac/dc)
Cons. (mA) without door release:Relay contact:Operating temperature:Reading distance(card/keyring):PC Interface:
Radiofrequencystand-alone
Trinary RF emitter (ref.79561)
Radiofrequency emitter 433.92MHz.Trinary technology.New and highly robust design.Dual channel emitter that can activate two relays.Configuration of the sequence of digits required bymeans of microswitches.Simple and easy to use.
Available in kit (ref.7910 y ref.7911) 25
Installation
RF EmitterRef.79561
Door release
Receiver
2
ST
AN
D-A
LO
NE
Dip switch configuration (8 microswitches in 3 positions).
Unlimited number of users admitted by the receiver.
Includes battery 12Vdc.
Range: 30m.
Frequency: 433.92 MHz.
Consumption in transmission: 10mA
Consumption in standby: 0.1mA
Technical features
Compatible with ref.7952 Single channel receiver for garages.
ref.7900 Single channel receiver PCB (OEM).
ref.7903 Single channel receiver DIN rail.
Specifications Dimensions (WxHxDmm): 53x36x13mm
2
2RF emitterRef.79561
Door release
Ref.7952
Alarm
Ref.7934
Compatible with Trinary emitter (ref.79561)
Radiofrequencystand-alone
Single channel receiver 433.92MHz.Trinary technology.When the code emitted by the trinary emitter(ref.79561) is received, the receiver closes a circuitthat triggers the electric lock or door automation.Mounted in watertight box (IP65) in ABS.Programming by 8 microswitches in 3 positions.
Receiver for garages (ref.7952)
ST
AN
D-A
LO
NE
Includes rigid antenna 25 cm.
Optionally, by adding card ref.7934, the receiver can be
turned into dual channel to trigger a second relay.
Reception frequency: 433.92 MHz.
Sensitivity: 3 mV
Relay contact: 2 A max.
Power supply: 220Vac/50Hz
Consumption: 110 mA in standby.
Installation
Specifications Dimensions (WxHxDmm): 90x165x55mm
26 Available in kit (ref.7911)
Technical features
Radiofrequencystand-alone
Trinary dip switch configuration (8 microswitches in 3 positions).
Power supply: 12 Vdc/12 Vac.
Frequency: 433.92 MHz.
Output 12Vac to activate an electric lock.
Output for pushbutton connection to open the door from
inside.
Single channel receiver 433.92MHz.Trinary technology.The receiver admits all emitters (ref.79561)programmed with the same code.Can be installed in any FERMAX audio or video doorentry panel.
Single Channel Receiver (ref.7900)
Compatible with Trinary emitter (ref.79561)
27
Exitbutton
2
RF emitter(ref.79561)
Power supply
Ref.7900(To be installed inside theflush box).
Door release
2
230Vac
2
ST
AN
D-A
LO
NE
Installation
Technical features
Specifications Dimensions (WxHxDmm): 20x70x60mm
Radiofrequencystand-alone
Single channel receiver 433.92MHz.Trinary technology.The receiver admits all emitters (ref.79561)programmed with the same code.Includes, in DIN6 format, the RF receiver andtransformer or power supply.Ideal for shops, offices and businesses.
DIN rail receiver (ref.7903)
Compatible with Trinary emitters (ref.79561)
Electric cabinet
Ref. 7903REF.7903
ST
AN
D-A
LO
NE
Installation
Direct connection to 220Vac/50Hz.
DIN rail or wall mounted.
Output for pushbutton connection to open door from
inside.
Frequency: 433.92 MHz.
Trinary dip switch configuration (8 microswitches in 3
positions).
Output 12Vac for an electric lock activation.
Dimensions: 6-element DIN.
28 Available in kit (ref.7910)
Technical features
RF emitterRef. 79561
Specifications Dimensions (WxHxDmm): 105x90x60mm
29Available in kit (ref.7912)
Radiofrequencystand-alone
Unique and exclusive code per emitter.
Includes battery 12Vdc.
Range: 30m.
Frequency: 433.92 MHz.
Consumption in transmission: 10 mA.
Consumption in standby: 0.1mA
Radiofrequency emitter 433.92MHz.Digital Technology.New and highly robust design.Dual channel emitter that can activate two relays.Secure code, unique, non configurable and exclusiveas standard per emitter.It is necessary to authorize/cancel emitters in thereceivers.
RF digital emitter (ref.24651)
ST
AN
D-A
LO
NE
Installation
Compatible with Ref.7960 Villa receiver (stand-alone).
Ref.1065 MDS receiver (centralized).
Ref.2464 MDS Secondary receiver (centralized).
Technical features
2RECEPTOR SEGURIDADSECURITY RECEIVERREF. 24561
RF emitterRef. 24651
Door release
RF receiverRef.7960
Specifications Dimensions (WxHxDmm): 53x36x13mm
Radiofrequencystand-alone
Radiofrequency receiver 433.92MHz.Digital technology.Only authorized digital (ref.24651) or dual (ref.25511)emitters will trigger the device.Reduced size enables installation in electricalcabinets (embeddable in standard boxes 10x10cm).Emitters must be authorized in the receiver.
Villa Receiver (ref.7960)
Compatible with Digital (ref.24651) or dual (ref.25511) emitters.
ST
AN
D-A
LO
NE
Specifications Dimensions (WxHxDmm): 62x70x20mm
30 Available in kit (ref.7912)
Power supply 12Vac/12Vdc.
Lets you store up to 10 emitters (users) in memory with
unique and different codes.
Electric lock activation by relay. Programmable timing.
Exit pushbutton input.
Frequency: 433.92 MHz.
Door open time programming by dip-switch.
Technical features
Installation2
RECEPTOR SEGURIDADSECURITY RECEIVERREF. 7960
RF emitterRef. 24651
Door release
ReceiverRef.7960
Radiofrequencystand-alone
In addition to the RF functions, incorporates proximity
card electronics for use in any proximity reader.
Includes battery 12Vdc.
Range: 30m.
Proximity reader distance: 2 cm.
Frequency: 433.92 MHz.
Consumption in transmission: 10mA.
Consumption in standby: 0.1mA
31
Radiofrequency emitter 433.92MHz.Dual technology.New and highly robust design.Dual channel emitter can activate two relays.Secure code, unique, non configurable and exclusiveas standard per emitter.It is necessary to authorize/cancel emitters in thereceivers.Internally integrates proximity card electronics so canbe used as a dual channel emitter and as substituteidenti f ier for proximity cards or keyrings.
Dual RF emitter (ref.25511)
Installation
RF emitterRef.25511
Door release
Receiver for garages
2
ST
AN
D-A
LO
NE
Specifications Dimensions (WxHxDmm): 53x36x13mm
Compatible with Ref.7960 Villa receiver (stand-alone).
Ref.1065 MDS receiver (centralized).
Ref.2464 MDS secundary receiver (centralized).
Technical features
Power supply
Ref.4477
Door release
Exitbutton
2
2
230Vac
2
BluetoothTM
Bluetoothstand-alone
Access control reader by Bluetooth technology wherethe mobile telephone acts as user identifier.Manufactured in aluminium.Flush or surface mounted (ref.8851).Recommended for interiors and exteriors.Reader and controller in the same module.
ST
AN
D-A
LO
NE
Electric lock activation by relay.
Programmable relay time (monostable, bistable).
Several operating modes: authorized personnel only (capacity
40 users) or without user limits.
In “authorized personnel only” mode the door can be opened
totally hands free, with key confirmation or PIN code. In “no
user limit” mode the door is always opened by a PIN.
Configurable reader range: up to 2m, 9m or 20m.
Programmation Programming can be done in three ways: through a master
mobile (recognized by the reader when powered up the first
time) with simple and intuitive commands, by PC with Bluetooth
connection (software downloadable from www.fermax.com)
or by PDA with Bluetooth.
Specifications Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Enviromental protection (IP):Protection against knocks (IK):
12V (ac/dc) 80/200 2A (NA,NC)
0 to 70ºC
130x128x18115x114x45130x128x33
4307
Power supply (V):Cons. (mA) without door release:Relay contact:
Operating temperatue:Programmable from 01 to 99 sec. or bistable
City Bluetooth (ref.4477)
32 Available in kit (ref.4478)
Installation The reader is located in the outside zone. The rest of thedevices, installed indoors, are connected to it: power supplyand electric lock.
Technical features
BluetoothTM
BluetoothTM
Power supply
Ref.4476
Door release
Exitbutton
2
2
230Vac
2
2
BluetoothTM
CityMax Bluetooth (ref.4476)
Access control reader by Bluetooth technology where
the mobile telephone acts as user identifier.
To be fitted in the viewer of CityMax audio or video
door entry panels for enhanced security in the home.
Reader and controller in the same module.
33
Bluetoothstand-alone
ST
AN
D-A
LO
NE
Specifications
The audio or video door entry panel is located in the outsidearea. It is possible to set up the panel intuitively to includea reader (ref.4476) for greater security and more convenientaccess.
Electric lock activation by relay.
Programmable relay time (monostable, bistable).
Several operating modes: authorized personnel only (capacity
40 users) or without user limits.
In “authorized personnel only” mode the door can be opened
totally hands free, with key confirmation or PIN code. In “no
user limit” mode the door is always opened by a PIN.
Configurable reader range: up to 2m, 9m or 20m.
Programmation Programming can be done in three ways: through a master
mobile (recognized by the reader when powered up the first
time) with simple and intuitive commands, by PC with Bluetooth
connection (software downloadable from www.fermax.com)
or by PDA with Bluetooth.
Enviromental protection (IP):Protection against knocks (IK):Power supply (V):Consumption (mA) without door release:Relay contact:Programmable from 01 to 99 sec. or bistableOperating temperature:
4307
12V (ac/dc)6/60
2A (NA,NC)
0 to 70ºC
Installation
Technical features
Fingerprintstand-alone
City fingerprint (ref.6990)
Fingerprint reader with thermal sensor and storagecapacity for 950 prints.Manufactured in aluminium in new City styling.Flush or surface mounted.Recommended for interiors and exteriors.Reader and controller integrated in the samemodule.
ST
AN
D-A
LO
NE
34 Available in kit (ref.6988)
Programmation The system is programmed with one fingerprint (the
administrator’s) and with a remote infrared keypad for
user authorizations/cancellations.
Installation The reader is located in the outside zone. The rest of
the devices, installed indoors, are connected to it: power
supply and electric lock. Optionally, an exit pushbutton
can be used if there is no door handle (LOFT model) to
detect if the door remains open.
Exit pushbutton and free access button input.
Number of users:
- 950 in 1 fingerprint per person mode.
- 630 in 2 fingerprints per person mode.
2 status signal LEDs: door open/closed.
Display 7-3-digit segments.
Infrared receiver for programming.
Electric lock activation by relay and one auxiliary relay.
Programmable relay times (monostable, bistable).
Specifications Dimensions (WxHxDmm):Flush box (included):Superface box (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):
12V (ac/dc) 6/602A (NA,NC) 0 to 60ºC
130x128x18115x114x45130x128x33
4307
Power supply (V):Consumtion (mA) without door release:Relay contact:Operating temperature:
Power supply
Ref.6990
Door release
Exitbutton
2
2
230Vac
2
2
Technical features
35
City fingerprint module (ref.6989)
Fingerprint reader with thermal sensor and storagecapacity for 950 prints.To be fitted in the viewer of CityMax audio or videodoor entry panels for enhanced security in the home.Reader and controller integrated in the same module.
Fingerprintstand-alone
ST
AN
D-A
LO
NE
Programmation The system is programmed with one fingerprint (the
administrator) and with a remote infrared keypad for user
authorizations/cancellations.
The audio or video door entry panel is located in the
outside area. It is possible to set up the panel intuitively
to include a reader (ref. 6989) for greater security and
more convenient access.
Installation
Exit pushbutton and free access button input.
Number of users:
- 950 in 1 fingerprint per person mode.
- 630 in 2 fingerprint per person mode.
2 status signal LEDs: door open/closed.
Display 7 3-digit segments.
Infrared receiver for programming.
Electric lock activation by relay and one auxiliary relay.
Programmable relay times (monostable, bistable).
Specifications Environmental protection (IP):Protection against knocks (IK):Power supply (V):
6/602A (NA,NC) 0 to 60ºC
43 07
12V (ac/dc)
Consumption (mA) without door release:Relay contact:Operating temperature:
Exitbutton
2
Technical features
Power supply
Ref.6989
Door release
2
230Vac
2
Access control systems consisting of several accesses (up to a maximum of 32) and PC managed.
S t a n d - a l o n e a c c e s s c o n t r o l i n n e t w o r k
ST
AN
D-A
LO
NE
IN
NE
TW
OR
K
38
Installation Installation in mechanism box 100x100mm or surface
mounted with 2 screws (included).
Programmed from a PC with the corresponding software
(included in ref.44201).Programmation
Each door controller manages 1.000 users.
The connection between controllers consists of 2 power
wires and a twisted pair for data.
Admits an exit and entrance reader, electric lock relay,
auxiliary relay for other functions, pushbutton connection,
door sensor and free access button.
Necessary for vehicle accesses for connection of entrance
or exit detection coils.
Status LEDs: transmission and reception.
Lets you connect any reader with Wiegand-26 output or
Magstrip (Aba TrackII or Dataclock).
Admits Dallas i-button key readers and matrix keypads in
8-bit burst format.
One power supply (ref.4813) recommended every 6 readers.
Technical features
Specifications Dimensions (WxHxDmm): 85x88x25Power supply (V): 12Vdc
Consumption (mA): 15/100Operating temperature: 0 to 60ºC
Door controller with 500 event memory (ref.44201).Includes CD with management software.The door controller manages the devices in each access: upto two readers (if they are used as entrance and exit), electriclock, door sensor and exit button.Up to 32 door controllers can be connected in series tomanage 32 entry and exit accesses.Thanks to the internal memory, it enables userauthorizations/cancellations and access permits/restrictionsfrom a PC.On-line incidents record. Capacity: 1.000 users.Indoor installation and separate from the reader for greatersecurity.Admits Wiegand-26 input or magstrip.
Door Controller (ref.44201)
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
( restricted area )
PRIVATE ACCESS CONTROL
( restricted area )
PRIVATE ACCESS CONTROL
Readers
Up to
32
Read
ers
Controllerstand-alone in network
PC connection accessory(needed) ref.24661
PC
2 wires
power supply
Door controllers (ref.44201)
ST
AN
D-A
LO
NE
IN
NE
TW
OR
K
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
( restricted area )
PRIVATE ACCESS CONTROL
( restricted area )
PRIVATE ACCESS CONTROL
Readers
Up to
32
Read
ers
PC connection accessory(needed) ref.24661
( restricted area )
PRIVATE ACCESS CONTROL
1 2 3
4 5 6
7 8 9
A 0 B
PC
2 wires
Power supply
Door controllers (ref.44201)
Specifications Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):
0712Vdc30mA
0 to 60ºC
130x175x18115x162x45130x175x33
43
Protection against knocks (IK):Power supply (V):Cons. (mA) without door release:Operating temperature:
Installation The reader is located outdoors and connected to the controller
located in the interior. Optionally, an exit pushbutton can be
used (if there is no door handle).
Can be combined with any Wiegand-26 bit or Dataclock
output reader.
Programming and start-up from PC software (included in
ref.44201).Programmation
City Memokey&Private WG combination (ref.4480)
Access control reader with dual technology: proximity and keypadwith capacity for up to 1.000 users.Stand-alone or joint operation for greater security: PIN code +card.Manufactured in aluminium in City styling.Flush or surface mounted.Recommended for interiors and exteriors.Door controller (ref.44201) required for operation.
Identifiers ref.23361 ref.2336 ref.2336 ref.2364 ref.44501
Withoutpersonalizing and with
magnetic strip.
Customizable(photo, name,company...)
For replacementwith magnetic
strip.
Without personalizingand without
magnetic strip.
Proximitykeyring
39
Memokey&Private WGstand-alone in network
Technical features Output in Wiegand-26 bit or Dataclock format.
Wiegand (WG) readers equip the installation with access
control with anti-sabotage security, as neither the door opening
mechanism nor the exit button connection are built-in. These
functions are supported by the door controller with memory
(ref.44201).
The reader can be used with other door controllers using
Wiegand-26 or Dataclock protocols.
Built-in status LEDs: door open/closed/power supply.
ST
AN
D-A
LO
NE
IN
NE
TW
OR
K
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
( restricted area )
PRIVATE ACCESS CONTROL
( restricted area )
PRIVATE ACCESS CONTROL
Readers
1 2 3
4 5 6
7 8 9
A 0 B
PC connection accessory(needed) ref.24661
PC
2 wires
Power supply
Door controllers (ref.44201)
40
Programming and start-up from PC software (included in
ref.44201).
ref.23361 ref.2336 ref.2336 ref.2364 ref.44501
Loft Memokey&Private WG (ref.4550)Access control reader with dual technology: proximity and keypadwith capacity for up to 1.000 users.Stand-alone or joint operation for greater security: PIN code +card.Manufactured in ABS plastic.Surface mounted.Recommended for interiors.Ideal for screen profiles in offices.Includes a 50cm cable.Door controller (ref.44201) required for operation.
The reader is located outdoors and connected to the controller
located in the interior. Optionally, an exit pushbutton can be
used (if there is no door handle).
Can be combined with any Wiegand-26 bit or Dataclock output
reader.
Up to
32
Read
ers
Specifications
Installation
Programmation
Identifiers
Withoutpersonalizing and with
magnetic strip.
Customizable(photo, name,company...)
For replacementwith magnetic
strip.
Without personalizingand without
magnetic strip.
Proximitykeyring
Memokey&Private WGstand-alone in network
Dimensions (WxHxDmm):Flush box (Not required):Surface box (Not required):Environmental protection (IP):
0612Vdc40mA
0 to 60ºC
60x130x23
66
Protection against knocks (IK):Power supply (V):Cons. (mA) without door release:Operating temperature:
Output in Wiegand-26 bit or Dataclock format.
Wiegand (WG) readers equip the installation with access control
with anti-sabotage security, as neither the door opening
mechanism nor the exit button connection are built-in. These
functions are supported by the door controller with memory
(ref.44201).
The reader can be used with other door controllers using
Wiegand-26 or Dataclock protocols.
Built-in status LEDs: door open/closed/power supply.
Technical features
ST
AN
D-A
LO
NE
IN
NE
TW
OR
K
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair ( restricted area )
PRIVATE ACCESS CONTROL
( restricted area )
PRIVATE ACCESS CONTROL
Readers
1 2 3
4 5 6
7 8 9
A 0 B PC connection accessory(needed) ref.24661
PC
2 wires
Power supply
Door controllers (ref.44201)
City Private WG (ref.4490)
Proximity card reader with capacity for up to 1.000users.Manufactured in aluminium.Flush or surface mounted (ref.8851).Recommended for interiors and exteriors.Door controller (ref.44201) required for operation.
ref.23361 ref.2336 ref.2336 ref.2364 ref.44501
Programming and start-up from PC software (included in
ref.44201).
The reader is located outdoors and connected to the controller
located in the interior. Can be combined with any Wiegand-
26 bit or Dataclock output reader.
Up to
32
Read
ers
Specifications
Installation
Programmation
Identifiers
Withoutpersonalizing and with
magnetic strip.
Customizable(photo, name,company...)
For replacementwith magnetic
strip.
Without personalizingand without
magnetic strip.
Proximitykeyring
41
Private WGstand-alone in network
Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):Power supply (V):
30mA0 to 60ºC
6/5 cmRS-485/USB
130x128x18115x114x45130x128x33
4307
12Vdc
Cons. (mA) without door release:Operating temperature:Reading distance(card/keyring):PC Interface:
Output in Wiegand-26 bit or Dataclock format.
Wiegand (WG) readers equip the installation with access
control with anti-sabotage security, as neither the door opening
mechanism nor the exit button connection are built-in. These
functions are supported by the door controller with memory
(ref.44201).
The reader can be used with other door controllers using
Wiegand-26 or Dataclock protocols.
Built-in status LEDs: door open/closed/power supply.
Technical features
ST
AN
D-A
LO
NE
IN
NE
TW
OR
K
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
( restricted area )
PRIVATE ACCESS CONTROL
( restricted area )
PRIVATE ACCESS CONTROL
Readers
Up to
32
Read
ers
1 2 3
4 5 6
7 8 9
A 0 B PC connection accessory(needed) ref.24661
2 wires
PC
Power supply
Door controllers (ref.44201)
42
Bruto Private WG (ref.4510)
Proximity card reader with capacity for up to 1.000users.Vandal-proof panel.Flush or surface mounted (ref.2778).Recommended for interiors and exteriors.Door controller (ref.44201) required for operation.
ref.23361 ref.2336 ref.2336 ref.2364 ref.44501
Programming and start-up from PC software (included in
ref.44201).
Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxPmm):Environmental protection (IP):Protection against knocks (IK):Power supply (V):
300 to 60ºC
4/2 cmRS-485/USB
135x130x18115x100x45135x131x42
5309
12Vdc
Cons. (mA) without door release:Operating temperature:Reading distance(card/keyring):PC Interface:
The reader is located outdoors and connected to the controller
located in the interior. Optionally, an exit pushbutton can be
used (if there is no door handle).
Can be combined with any Wiegand-26 bit or Dataclock output
reader.
Specifications
Installation
Programmation
Identifiers
Withoutpersonalizing and with
magnetic strip.
Customizable(photo, name,company...)
For replacementwith magnetic
strip.
Without personalizingand without
magnetic strip.
Proximitykeyring
Private WGstand-alone in network
Output in Wiegand-26 bit or Dataclock format.
Wiegand (WG) readers equip the installation with access control
with anti-sabotage security, as neither the door opening
mechanism nor the exit button connection are built-in. These
functions are supported by the door controller with memory
(ref.44201).
The reader can be used with other door controllers using
Wiegand-26 or Dataclock protocols.
Built-in status LEDs: door open/closed/power supply.
Technical features
ST
AN
D-A
LO
NE
IN
NE
TW
OR
K
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
( restricted area )
PRIVATE ACCESS CONTROL
( restricted area )
PRIVATE ACCESS CONTROL
Readers
Up to
32
Read
ers PC connection accessory
(needed) ref.24661
PC
2 wires
Power supply
Door controller (ref.44201)
Loft Private WG (ref.4560)
Proximity card reader with capacity for up to 1.000users.Manufactured in ABS plastic.Surface mounted.Recommended for interiors.Ideal for screen profiles in offices.Includes a 50cm cable.Door controller (ref.44201) required for operation.
Programming and start-up from PC software (included in
ref.44201).
The reader is located outdoors and connected to the controller
located in the interior. Optionally, an exit pushbutton can be
used (if there is no door handle).
Can be combined with any Wiegand-26 bit or Dataclock output
reader.
Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):Power supply (V):
400 to 60ºC
6/5 cmRS-485/USB
60x130x23Not requiredNot required
6606
12V (ac/dc)
Cons. (mA) without door release:Operating temperature:Reading distance(card/keyring):PC Interface:
Specifications
Installation
Programmation
ref.23361 ref.2336 ref.2336 ref.2364 ref.44501Identifiers
Withoutpersonalizing and with
magnetic strip.
Customizable(photo, name,company...)
For replacementwith magnetic
strip.
Without personalizingand without
magnetic strip.
Proximitykeyring
43
Private WGstand-alone in network
Output in Wiegand-26 bit or Dataclock format.
Wiegand (WG) readers equip the installation with access control
with anti-sabotage security, as neither the door opening
mechanism nor the exit button connection are built-in. These
functions are supported by the door controller with memory
(ref.44201).
The reader can be used with other door controllers using
Wiegand-26 or Dataclock protocols.
Built-in status LEDs: door open/closed/power supply.
Technical features
ST
AN
D-A
LO
NE
IN
NE
TW
OR
K
The reader is located outdoors and connected to the controller
located in the interior.
Can be combined with any Wiegand-26 bit or Dataclock
output reader.
Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):
0712Vdc
300 to 60ºC
130x128x18115x114x45130x128x33
43
Protection against knocks (IK):Power supply (V):Consumption (mA) without door release:Operating temperature:Specifications
Installation
Programmation
44
Fingerprint WG
City WG fingerprint (ref.6990)
Fingerprint reader with thermal sensor and storagecapacity for 1.000 prints.Manufactured in aluminium in new City styling.Flush or surface mounted.Recommended for interiors and exteriors.Door controller (ref.44201) required for operation.
stand-alone in network
City fingerprint WG (ref.6990)
Door controller (ref.44201) required for operation.
Output in Wiegand-26 bit or Dataclock format.
Wiegand (WG) readers equip the installation with access
control with anti-sabotage security, as neither the door opening
mechanism nor the exit button connection are built-in. These
functions are supported by door controller with memory
(ref.44201).
The reader can be used with other door controllers using
Wiegand-26 or Dataclock protocols.
Built-in status LEDs: door open/closed/power supply.
Display 7 3-digit segments.
Infrared receiver for programming.
Number of users:
- 950 in 1 person mode.
- 630 in 2 fingerprint mode.
The system is programmed with one fingerprint (the
administrator’s) and with a remote infrared keypad for user
authorizations/cancellations.
User authorizations and cancellations can be done from a PC
with the software included in the door controller (ref.44201).
Technical features
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
( restricted area )
PRIVATE ACCESS CONTROL
( restricted area )
PRIVATE ACCESS CONTROL
Readers
Up to
32
Read
ers PC connection accessory
(needed) ref.24661
PCconnectionaccessory(needed)ref.24661
PC
2 wires
Power supply
Door controller (ref.44201)
ST
AN
D-A
LO
NE
IN
NE
TW
OR
KThe reader is located outdoors and connected to the controller
located in the interior. Optionally, an exit pushbutton can be
used (if there is no door handle).
Can be combined with any Wiegand-26 bit or Dataclock
output reader.
Environmental protection (IP):Protection against knocks (IK):Power supply (V):
300 to 60ºC
4307
12Vdc
Consumption (mA) without door release:Operating temperature:
45
Specifications
Installation
Programmation
City WG Module Fingerprint (ref.6989)
Fingerprint reader with thermal sensor and storage capacityfor 1.000 prints.To be fitted in the spare space of CityMax audio or videodoor entry panels for enhanced security in the home.Door controller (ref.44201) required for operation.
Fingerprint WGstand-alone in network
Output in Wiegand-26 bit or Dataclock format.
Wiegand (WG) readers equip the installation with access
control with anti-sabotage security, as neither the door opening
mechanism nor the exit button connection are built-in. These
functions are supported by the door controller with memory
(ref.44201).
The reader can be used with other door controllers using
Wiegand-26 or Dataclock protocols.
Built-in status LEDs: door open/closed/power supply.
Display 7 3-digit segments.
Infrared receiver for programming.
Number of users:
- 950 in 1 person mode.
- 630 in 2 fingerprint mode.
The system is programmed with one fingerprint (the
administrator’s) and with a remote infrared keypad for user
authorizations/cancellations.
User authorizations and cancellations can be done from a PC
with the software included in the door controller (ref.44201).
Technical features
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
2 wires
twisted pair
( restricted area )
PRIVATE ACCESS CONTROL
( restricted area )
PRIVATE ACCESS CONTROL
Readers
Up to
32
Read
ers
PC conectionaccessory (needed)
ref.24661
PCconnectionaccessory(needed)ref.24661
PC
2 wires
Power supply
Door controllers (ref.44201)
Systems that let you approach complex installations with advanced functions and a multitude of accesses.
C e n t r a l i z e d A c c e s s C o n t r o l
CE
NT
RA
LIZ
ED
Specifications Dimensions (WxHxDmm):Fixation: DIN rail or 2 screws to wallPower supply (V):
1500 to 60ºC
175x90x40
12Vdc
Cons. (mA) without door release:Operating temperature:
Each Central Unit manages:
2.048 users.
32 accesses.
3.000 incidents (entries, exits, access
denied, alerts, etc) in memory, with no need to
download to PC.
Managing up to 1.000 intercom panels, 1.000
sensors and 1.000 relays.
The readers connectable to the Central Unit are with built-
in or external controller (ref.4420).
Technical features
All programming is done with CAC software from one or
several duly authorized on line or remote computers.
Programmation
48
CAC Central Unit (ref.4410)
Central Unit that lets you approach complex access controlinstallations handling up to 32 accesses or doors with atotal of 2048 users.A maximum of 64 central units can be connected (2048accesses).Includes four management softwares: CAC Data BaseServer, CAC Server, CAC Access and CAC Time &Attendance.The Central Unit also monitors up to 1.000 sensors and1.000 relays for automatic functions.Local (USB, RS-232) or remote (IP) connection to PC viathe corresponding module (see accessories section).
Installation
CAC Central Unitcentralized
2 wires
twisted pairReader
2 wires
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.4410)
2 wires
twisted pair
Up to 64 Central Units
2 wires
twisted pairReader
Up to 32 readers
Reader
2 wires
twisted pair
twis
ted
pair
........ ........
Power supply 12 Vdc
1 2 3
4 5 6
7 8 9
A 0 B
Up to 32 readersUp to 32 readers
1 2 3 A
654 0
B987
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.4410)
( restricted area )
PRIVATE ACCESS CONTROL
1 2 3
4 5 6
7 8 9
A 0 B
( restricted area )
PRIVATE ACCESS CONTROL
1 2 3
4 5 6
7 8 9
A 0 B
1 2 3
4 5 6
7 8 9
A 0 B
CE
NT
RA
LIZ
ED
Needs CAC Data Base Server software installed(manages the SQL database) and CAC Server. Bothincluded in the central unit.Software included in the Central Unit (ref.4410) tomanage readers, user groups and advanced accesscontrol functions.Friendly graphic interface, simple and intuitive witha framework similar to Outlook©.All the options can be viewed in a hierarchic tree:doors, user profiles, schedules, automation.TCP/IP client server architecture.
CAC Access
Technical features
49
Software CAC Accesscentralized
2.048 users.
64 user groups (profiles). Each one defines the restrictions that are applied to the group by allocation of up to 3
areas and 3 schedules.
4 special profiles without user restrictions.
Special treatment for vehicles (parking areas).
32 areas. They define the doors to which access is allowed.
32 schedules. They define the periods of time when access is allowed to users.
On-line record of the last 3000 incidents (entries, exits, access denied, alerts, etc).
32 weekly device activation schedules (sensors/relays).
Capacity limitation in certain rooms or premises to a number of people.
Door blocking/unblocking.
Temporary user blocking individually or by groups. Access not permitted until they are unblocked.
Option to assign timed and physical expiry of proximity cards (typical application in hotels).
Automatic change of winter/summer time.
Anti-pass back function, which prevents two people using the same identifier to access the facility. The doors that
belong to the installation perimeter are defined and are checked to see if the user is inside or outside the perimeter
when coming through them.
There are two anti-passback levels associated with the same identifier, depending on how the facility is accessed,
by pedestrian door or for vehicles (the type of door is defined by the «CAC Control Server» application).
All the users may be located outside the perimeter at a set programmed time.
Continuous testing of devices.
Firmware update in installation. Lets you update the central unit with new versions or functions and resolve problems.
Activation of devices associated to each user, presenting the identifier in a reader.
Relay activation from a reader with keyboard and proximity. Alarms connection and disconnection.
CE
NT
RA
LIZ
ED
CAC Time & Attendance
Needs CAC Data Base Server software installed(manages the SQL database) and CAC Server. Bothincluded in the central unit.Software included in Central Unit (ref.4410) formanaging entry/exit of people, clock-ins andcalculating hours worked for wages processing.Friendly graphic interface, simple and intuitive witha framework similar to Outlook©.All the options can be viewed in a hierarchic tree:doors, user profiles, schedules, automation.
50
Technical features
Software CAC Time & Attendancecentralized
2048 users.
64 user groups (profiles). Each one defines the restrictions that are applied to the group by allocation of up to 3
areas and 3 schedules.
4 special profiles without user restrictions.
32 schedules. They define the periods of time when access is allowed to users.
Vacations (20 holidays and 3 vacation periods).
Record of the last 3.000 incidents (entries, exits, etc).
People location control for emergency evacuations.
Allocation of events in the exit readers by PIN code (doctor, commercial visit, etc).
Generation of daily, weekly or monthly information: actual hours, delays, overt ime, etc.
Door blocking/unblocking.
Temporary user blocking individually or by groups. Access not permitted until they are unblocked.
Automatic change of winter/summer time.
Manual change of anomalies in employee presence.
Continuous testing of devices.
Firmware update in installation. Lets you update the central unit with new versions or functions and resolve problems.
Activation of devices associated to each user, presenting the identifier in a reader.
Relay activation from a reader with keyboard and proximity. Alarms connection and disconnection.
CE
NT
RA
LIZ
ED
All programming is done with Wincom+ software from
one or several duly authorized on-line or remote computers.
Central Unit MDS (ref.2405)
Central Unit that lets you approach complex MDS audioand video door entry systems combined with accesscontrol functions.Each Central Unit is able to manage up to 10.000 houses,1.022 users and 31 audio or video door entry or accesscontrol panels.Can connect up to a maximum of 63 central units (approx.2.000 accesses).Wincom+ management so f tware inc luded.The Central Unit also monitors up to 1.000 sensors and1.000 relays for automatic functions.Local (USB, RS-232) or remote (IP) connection to PC viathe corresponding module (see accessories section).
Each Central Unit manages:
1.022 users.
31 accesses (audio, video door entry or access
control readers).
3.000 incidents (entries, exits, access
denied, alerts, etc.) in memory, with no need to
download to PC.
Managing up to 1.000 intercom panels, 1.000
sensors and 1.000 relays.
Capacity of 10 guard units.
The readers connectable to the Central Unit are with built-
in or external controller (ref.4420).
Technical features
Programmation
Installation
2 wires
twisted pair
Central Unit(ref.2405)
2 wires
twisted pair
Reader
Up to 64 Central Units
2 wires
twisted pair
Up to 32 elements
2 wires
twisted pair
twis
ted
pair
Power supply 12Vdc
Video panel Audio panel
Up to 32 elements
................
51
Central Unit MDScentralized
( restricted area )
PRIVATE ACCESS CONTROL
1 2 3
4 5 6
7 8 9
A 0 B
2 wires
CE
NT
RA
LIZ
ED
Software included in Central Unit (ref.2405) tomanage complex audio, video door entry andaccess control installations.Management of all the parameters from a uniquesoftware with framework similar to Outlook©.All the options can be viewed in a hierarchic tree:doors, user profiles, schedules, automation.
Wincom+ Software
52
Wincom+ Softwarecentralized
Technical features
1022 users
64 user groups (profiles). Each one defines the restrictions that are applied to the group by allocation of up to 3
areas and 3 schedules.
32 areas. They define the doors to which access is allowed.
32 schedules. They define the periods of time when access is allowed to users.
On-line record of the last 3.000 incidents (entries, exits, access denied, alerts, etc), all exportable to Excel.
Vacations (20 holidays and 3 vacation periods).
Installation configuration and testing.
2 user levels (administrator, operator).
Lift control.
Perimeter anti-passback function.
Capacity limitation in certain rooms or premises to a number of people.
Door blocking/unblocking.
Activation of devices associated to each user, presenting the identifier in a reader.
Relay activation from a reader with keyboard and proximity. Alarms connection and disconnection.
CE
NT
RA
LIZ
ED
Installation
Door controller without memory (ref.4420).Manages the devices present in each access: upto two readers (if they are entry and exit), electriclock, door sensor and exit button.Installation indoors and separated from readerfor higher security.Input Wiegand-26, magstrip or ibutton.
Door Controller (ref.4420)
Specifications Dimensions (WxHxDmm): 85x88x25Power supply (V): 12Vdc
Consumption: 15mA / 100mAOperating temperature: 0 to 60ºC
Connection between controllers consists of 2 power cables
and one twisted pair for data.
Admits an exit and entry reader, electric lock relay, auxiliary
relay for other functions, connection button, door sensor
and free access.
Dip switch to encode the door number, reader type and
access type (pedestrian or vehicle).
Necessary in vehicle accesses for connection of entrance
or exit detection coils.
Lets you connect any reader with Wiegand-26 input,
Magstrip (Aba Track II or Dataclock).
Lets you connect button key type readers Dallas i-button
and matrix keypads in 8-bit burst format.
Test button to check the correct installation of all devices
connected to the controller.
Technical features
Installation in mechanism box 100x100mm or surface
mounted with 2 screws (included).
Central Unit(ref.4410 o ref.2405)
2 wires
twisted pair
Reader
Up to 64 Central Units
Up to 32 readers
Reader
2 wires
twisted pair
twis
ted
pai
r
2 wires
7 wire
s
7 wire
s
7 wire
s
Reader Reader Reader
7 wire
s
7 wire
s
53
Controllercentralized
A 0 B
1 2 3
4 5 6
7 8 9
( restricted area )
PRIVATE ACCESS CONTROL
( restricted area )
PRIVATE ACCESS CONTROL
Power supply 12Vdc
Doorcontrollerref.4420
Doorcontrollerref.4420
Doorcontrollerref.4420
Doorcontrollerref.4420
Doorcontrollerref.4420
CE
NT
RA
LIZ
ED
54
Specifications Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):
0712Vdc
200 to 60ºC
130x128x18115x114x45130x128x33
43
Protection against knocks (IK):Power supply (V):Cons. (mA) without door release:Operating temperature:
Programming from PC software corresponding to installed
Central Unit (ref.2405 or ref. 4410).Programmation
Exit pushbutton input, door sensor input and electric lock
relay.
2-wire cables for power supply and twisted pair for data.
Dip switch to encode door number and electric lock activation
timing.
Requires external relay (ref.2013) if activating electric lock
with consumption over 500mA, inverted function or external
device (motor, barrier).
Technical features
Access control keypad with capacity up to 100different 4- to 6-digit codes.Manufactured in aluminium.Flush or surface mounted (ref .8851).Recommended for interiors and exteriors.Reader and controller in the same module.No door controller required (ref.4420).
City Memokey MDS (ref.23291)
2 wires
twistedpairReader
2 wires
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.2405 or 4410)
2 wires
twistedpair
Up to 64 Central Units
2 wires
twistedpairReader
Up to 32 readers
Reader
2 wires
twistedpair
twis
ted
pair ........ ........
Power supply 12 Vdc
1 2 3
4 5 6
7 8 9
A 0 B
Up to 32 readersUp to 32 readers
Memokeycentralized
1 2 3 A
654 0
B987
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.4410)
1 2 3
4 5 6
7 8 9
A 0 B
1 2 3
4 5 6
7 8 9
A 0 B
1 2 3
4 5 6
7 8 9
A 0 B
CE
NT
RA
LIZ
ED
Specifications Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):
0912Vdc
0 to 60ºC
135x130x18115x100x45135x131x42
53
Protection against knocks (IK):Power supply (V):Operating temperature:
Access control keypad with capacity up to 100 different4- to 6-digit codes.Vandal-proof panel.Flush or surface mounted (ref.2778).Recommended for inter iors and exter iors.Reader and controller integrated in the same module.Ideal for troubled zones or districts, offices, banks, etc.No door controller required (ref.4420).
Bruto Memokey MDS (ref.2553)
Programmation Programming from PC software corresponding to installed
Central Unit (ref.2405 or ref.4410).
Exit pushbutton input, door sensor input and electric lock
relay.
2-wire cable for power supply and twisted pair for data.
Dip switch to encode door number and electric lock
activation timing.
Requires external relay (ref.2013) if activating electric lock
with consumption over 500mA, inverted function or
external device (motor, barrier).
Technical features
Installation
2 wires
twistedpairReader
2 wires
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.2405 or 4410)
2 wires
twistedpair
Up to 64 Central Units
2 wires
twistedpairReader Reader
2 wires
twistedpair
twis
ted
pair
........ ........
Power supply 12 Vdc
Up to 32 readersUp to 32 readers
Up to 32 readers
55
Memokeycentralized
1 2 3 A
654 0
B987
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.4410)
( restricted area )
PRIVATE ACCESS CONTROL
( restricted area )
PRIVATE ACCESS CONTROL
1 2 3
4 5 6
7 8 9
A 0 B
1 2 3
4 5 6
7 8 9
A 0 B
CE
NT
RA
LIZ
ED
56
Specifications
Installation
City Memokey&Private WG (ref.4480)Dual technology access control reader: proximity and keypad.Stand-alone or joint operation for greater security: PIN code+ card.Manufactured in aluminium in City style.Flush or surface mounted.Recommended for interiors and exteriors.Door controller (ref.4420) required for operation.
Identifiers ref.23361 ref.2336 ref.2336 ref.2364 ref.44501
Withoutpersonalizing and with
magnetic strip.
Customizable(photo, name,company...)
For replacementwith magnetic
strip.
Without personalizingand without
magnetic strip.
Proximitykeyring
Memokey&Private WGcentralized
Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Metalic box (WxHxDmm):Environmental protection (IP):
0712Vdc30mA
0 to 60ºC
130x175x18115x162x45130x175x33154x203x50
43
Protection against knocks (IK):Power supply (V):Cons. (mA) without door release: Operating temperature:
Programmation Programming from PC software corresponding to installed
Central Unit (ref.2405 or ref.4410).
Technical features Output in Wiegand-26 bit or Dataclock format.
Wiegand (WG) readers let you equip the access control
installation with anti-sabotage security, as neither the door
opening mechanism nor the exit button connection are
built-in. These functions are supported by door controller
(ref.4420).
The reader can be used with other door controllers using
Wiegand-26 or Dataclock protocols.
Built-in status LEDs: open door / closed / power supply.
2 wires
twistedpair
........
Reader
2 wires
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.2405 or 4410)
2 wires
twistedpair
Up to 64 Central Units
2 wires
twistedpairReader
Up to 32 readers
Reader
2 wires
twistedpair
twis
ted
pair
Power supply 12 Vdc
1 2 3
4 5 6
7 8 9
A 0 B
Up to 32 readersUp to 32 readers
2 wires
1 2 3
4 5 6
7 8 9
A 0 B
1 2 3 A
654 0
B987
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.4410)
( restricted area )
PRIVATE ACCESS CONTROL
1 2 3
4 5 6
7 8 9
A 0 B
1 2 3
4 5 6
7 8 9
A 0 B
Door controller(ref.4420)
7 wires
7 wires
7 wires 7 wires
CE
NT
RA
LIZ
ED
Specifications
ref.23361 ref.2336 ref.2336 ref.2364 ref.44501Identifiers
Loft Memokey&Private WG (ref.4550)Dual technology access control reader: proximity andkeypad.Stand-alone or joint operation for higher security: PIN code+ card.Manufactured in ABS plastic.Surface mounted.Recommended for interiors.Ideal for office screen profiles.Includes a 50cm cable.Door controller (ref.4420) required for operation.
Installation
Withoutpersonalizing and with
magnetic strip.
Customizable(photo, name,company...)
For replacementwith magnetic
strip.
Without personalizingand without
magnetic strip.
Proximitykeyring
57
Memokey&Private WGcentralized
60x130x23
66
Dimensions (WxHxDmm):Flush box (not required):Surface box (not required):Environmental protection (IP):
0612Vdc40mA
0 to 60ºC
Protection against knocks (IK):Power supply (V):Cons. (mA) without door release:Operating temperature:
Programmation Programming from PC software corresponding to installed
Central Unit (ref.2405 or ref.4410).
Technical features Output in Wiegand-26 bit or Dataclock format.
Wiegand (WG) readers let you equip the access control
installation with anti-sabotage security, as neither the door
opening mechanism nor the exit button connection are
built-in. These functions are supported by door controller
(ref.4420).
The reader can be used with other door controllers using
Wiegand-26 or Dataclock protocols.
Built-in status LEDs: open door / closed / power supply.
2 wires
twistedpair
........
Reader
2 wires
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.2405 or 4410)
2 wires
twistedpair
Up to 64 Central Units
2 wires
twistedpairReader
Up to 32 readers
Reader
2 wires
twistedpair
twis
ted
pair
Power supply 12 Vdc
1 2 3
4 5 6
7 8 9
A 0 B
Up to 32 readersUp to 32 readers
2 wires
1 2 3
4 5 6
7 8 9
A 0 B
1 2 3 A
654 0
B987
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.4410)
( restricted area )
PRIVATE ACCESS CONTROL
1 2 3
4 5 6
7 8 9
A 0 B
1 2 3
4 5 6
7 8 9
A 0 BDoor controller(ref.4420)
7 wires
7 wires
7 wires
CE
NT
RA
LIZ
ED
58
City Private MDS (ref.23351)
Specifications
Installation
Identifiers ref.23361 ref.2336 ref.2336 ref.2364 ref.44501
Proximity card reader with capacity up to:- 1.020 users with MDS central unit (ref.2405).- 2.048 users with CAC central unit (ref.4410).Manufactured in aluminium.Flush or surface mounted (ref.8851).Recommended for interiors and exteriors.Reader and controller integrated in the same module.No door controller required (ref.4420).
Technical features Exit pushbutton input, door sensor input and electric lock
relay.
2 wire cables for power supply and twisted pair for data to
central unit.
Dip switch to encode door number and electric lock activation
timing.
Requires external relay (ref.2013) if activating electric lock
with consumption over 500mA, inverted function or external
device (motor, barrier).
Programming from PC software corresponding to installed
Central Unit (ref.2405 or ref.4410).Programmation
2 wires
twistedpairReader
2 wires
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.2405 or 4410)
2 wires
twistedpair
Up to 64 Central Units
2 wires
twistedpairReader
Up to 32 readers
Reader
2 wires
twistedpair
twis
ted
pair ........ ........
Power supply 12 Vdc
1 2 3
4 5 6
7 8 9
A 0 B
Up to 32 readersUp to 32 readers
Withoutpersonalizing and with
magnetic strip.
Customizable(photo, name,company...)
For replacementwith magnetic
strip.
Without personalizingand without
magnetic strip.
Proximitykeyring
Privatecentralized
1 2 3 A
654 0
B987
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.4410)
Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):
0712Vdc
550 to 60ºC
130x128x18115x114x45130x128x33
43
Protection against knocks (IK):Power supply (V):Cons. (mA) without door release:Operating temperature:
( restricted area )
PRIVATE ACCESS CONTROL
( restricted area )
PRIVATE ACCESS CONTROL
1 2 3
4 5 6
7 8 9
A 0 B
CE
NT
RA
LIZ
ED
City Private WG (ref.4490)
ref.23361 ref.2336 ref.2336 ref.2364 ref.44501Identifiers
Specifications
Proximity card reader with capacity up to:- 1.020 users with MDS central unit (ref.2405).- 2.048 users with CAC central unit (ref.4410).Manufactured in aluminium.Flush or surface mounted (ref.8851).Recommended for interiors and exteriors.Door controller (ref.4420) required for operation.
Withoutpersonalizing and with
magnetic strip.
Customizable(photo, name,company...)
For replacementwith magnetic
strip.
Without personalizingand without
magnetic strip.
Proximitykeyring
Installation
twistedpairReader
2 wires
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.2405 or 4410)
2 wires
twistedpair
Up to 64 Central Units
2 wires
twistedpairReader
Up to 32 readers
Reader
2 wires
twistedpair
twis
ted
pair
........ ........
Power supply 12 Vdc
1 2 3
4 5 6
7 8 9
A 0 B
Up to 32 readersUp to 32 readers
Private WGcentralized
59
1 2 3 A
654 0
B987
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.4410)
1 2 3 A
654 0
B987
Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Protection environmental (IP):Protection against knocks (IK):Power supply (V):
30mA0 to 60ºC
6/5 cmRS-485/USB
130x128x18115x114x45130x128x33
4307
12Vdc
Cons. (mA) without door release:Temperature operating:Reading distance(card/keyring):PC Interface:
PRIVATE ACCESS CONTROL
( restricted area )
PRIVATE ACCESS CONTROL
Programmation Programming from PC software corresponding to installed
Central Unit (ref.2405 or ref.4410).
Technical features Output in Wiegand-26 bit or Dataclock format.
Wiegand (WG) readers let you equip the access control
installation with anti-sabotage security, as neither the door
opening mechanism nor the exit button connection are
built-in. These functions are supported by door controller
(ref.4420).
The reader can be used with other door controllers using
Wiegand-26 or Dataclock protocols.
Built-in status LEDs: open door / closed / power supply.
1 2 3
4 5 6
7 8 9
A 0 B
Door Controller(ref.4420)
2 wires7 wires
CE
NT
RA
LIZ
ED
Specifications
Identifiers ref.23361 ref.2336 ref.2336 ref.2364 ref.44501
60
Technical features Exit pushbutton input, door sensor input and electric lock
relay.
2-wire cables for power supply and twisted pair for data.
Dip switch to encode door number and electric lock activation
timing.
Requires external relay (ref.2013) if activating electric lock
with consumption over 500mA, inverted function or external
device (motor, barrier).
Programming from PC software PC corresponding to installed
Central Unit (ref. 2405 or ref.4410).Programmation
Proximity card reader with capacity up to:- 1.020 users with MDS central unit (ref.2405).- 2.048 users with CAC central unit (ref.4410).Vandal-proof panel.Flush or surface mounted (ref.2778).Recommended for interiors and exteriors.Reader and controller integrated in the same module.Ideal for troubled zones or districts, offices, banks, etc.No door controller required (ref.4420).
Bruto Private MDS (ref.2552)
Installation
2 wires
twistedpairReader
2 wires
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.2405 or 4410)
2 wires
twistedpair
Up to 64 Central Units
2 wires
twistedpairReader
Up to 32 readers
Reader
2 wires
twistedpair
twis
ted
pair ........ ........
Power supply 12 Vdc
1 2 3
4 5 6
7 8 9
A 0 B
Up to 32 readersUp to 32 readers
Withoutpersonalizing and with
magnetic strip.
Customizable(photo, name,company...)
For replacementwith magnetic
strip.
Without personalizingand without
magnetic strip.
Proximitykeyring
Privatecentralized
1 2 3 A
654 0
B987
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.4410)
1 2 3 A
654 0
B987
Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):
0912Vdc
550 to 60ºC
135x130x18115x100x45135x131x42
53
Protection against knocks (IK):Power supply (V):Cons. (mA) without door release:Operating temperature:
( restricted area )
PRIVATE ACCESS CONTROL
1 2 3
4 5 6
7 8 9
A 0 B
CE
NT
RA
LIZ
ED
Specifications
Installation
Identifiers ref.23361 ref.2336 ref.2363 ref.2364 ref.44501
Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):Power supply (V):
300 to 60ºC
4/2 cmRS-485/USB
135x130x18115x100x45135x131x42
5309
12Vdc
Cons. (mA) without door release:Operating temperature:Reading distance(card/keyring):PC Interface:
Bruto Private WG (ref.4510)Proximity card reader with capacity up to:- 1.020 users with MDS central unit (ref.2405).- 2.048 users with CAC central unit (ref.4410).Vandal-proof panel.Flush or surface mounted (ref.2778).Recommended for interiors and exteriors.Ideal for troubled zones or districts, offices, banks, etc.Door controller (ref.4420) required for operation.
twistedpairReader
2 wires
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.2405 or 4410)
2 wires
twistedpair
Up to 64 Central Units
2 wires
twistedpairReader
Up to 32 readers
Reader
2 wires
twistedpair
twis
ted
pair
........ ........
Power supply 12 Vdc
1 2 3
4 5 6
7 8 9
A 0 B
Up to 32 readersUp to 32 readers
Withoutpersonalizing and with
magnetic strip.
Customizable(photo, name,company...)
For replacementwith magnetic
strip.
Without personalizingand without
magnetic strip.
Proximitykeyring
7 wires
61
Private WGcentralized
1 2 3 A
654 0
B987
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.4410)
( restricted area )
PRIVATE ACCESS CONTROL
( restricted area )
PRIVATE ACCESS CONTROL
2 wires
Programmation Programming from PC software PC corresponding to
instal led Central Unit (ref. 2405 or ref.4410).
Technical features Output in Wiegand-26 bit or Dataclock format.
Wiegand (WG) readers let you equip the access control
installation with anti-sabotage security, as neither the door
opening mechanism nor the exit button connection are
built-in. These functions are supported by door controller
(ref.4420).
The reader can be used with other door controllers using
Wiegand-26 or Dataclock protocols.
Built-in status LEDs: open door / closed / power supply.
Door Controller(ref.4420)
1 2 3
4 5 6
7 8 9
A 0 B
7 wires
CE
NT
RA
LIZ
ED
62
Specifications
Private Loft WG (ref.4560)
Proximity card reader with capacity up to:- 1.020 users with MDS central unit (ref.2405).- 2.048 users with CAC central unit (ref.4410).Manufactured in ABS plastic.Surface mounted.Recommended for exteriors.Ideal for office screen profiles.Door controller (ref.4420) required for operation.Includes a 50 cm cable.
Installation
Technical features
Programmation Programming from PC software corresponding to installed
Central Unit (ref.2405 or ref.4410).
2 wires
twistedpairReader
2 wires
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.2405 or 4410)
2 wires
twistedpair
Up to 64 Central Units
2 wires
twistedpairReader
Up to 32 readers
Reader
2 wires
twistedpair
twis
ted
pair
......... ........
Power supply 12 Vdc
1 2 3
4 5 6
7 8 9
A 0 B
Up to 32 readersUp to 32 readers
7 wires
ref.23361 ref.2336 ref.2336 ref.2364 ref.44501
Withoutpersonalizing and with
magnetic strip.
Customizable(photo, name,company...)
For replacementwith magnetic
strip.
Without personalizingand without
magnetic strip.
Proximitykeyring
Identifiers
Private WGcentralized
1 2 3 A
654 0
B987
Central Unit(ref.4410)
1 2 3
4 5 6
7 8 9
A 0 B
Dimensions (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):Power supply (V):Cons. (mA) without door release:
0 to 60ºC
8/6 cmRS-485/USB
60x130x236606
12Vdc40
Operating temperature:Reading distance(card/keyring):PC Interface:
Output in Wiegand-26 bit or Dataclock format.
Wiegand (WG) readers let you equip the access control
installation with anti-sabotage security, as neither the door
opening mechanism nor the exit button connection are
built-in. These functions are supported by door controller
(ref.4420).
The reader can be used with other door controllers using
Wiegand-26 or Dataclock protocols.
Built-in status LEDs: open door / closed / power supply.
Door Controller(ref.4420)
1 2 3
4 5 6
7 8 9
A 0 B
7 wires
CE
NT
RA
LIZ
ED
City key button MDS (ref.23261)
Installation
Identifiers
Specifications
Access control reader whose operation is based onphysical contact between the reader head (socket)and authorized identi f ier (plug ref.2328).Number of users:- 1.020 users with MDS central unit (ref.2405).- 2.048 users with CAC central unit (ref.4410).Manufactured in aluminium.Flush or surface mounted.Recommended for interiors and exteriors.No door controller required (ref.4420).
Technical features Exit pushbutton input, door sensor input and electric lock
relay.
2-wire cables for power supply and twisted pair for data.
Dip switch to encode door number and electric lock activation
timing.
Requires external relay (ref.2013) if activating electric lock
with consumption over 500mA, inverted function or external
device (motor, barrier).
Programming from PC software corresponding to installed
Central Unit (ref.2405 or ref.4410).Programmation
2 wires
twistedpairReader
2 wires
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.2405 or 4410)
2 wires
twistedpair
Up to 64 Central Units
2 wires
twistedpairReader
Up to 32 readers
Reader
2 wires
twistedpair
twis
ted
pair ........ ........
Power supply 12 Vdc
1 2 3
4 5 6
7 8 9
A 0 B
Up to 32 readersUp to 32 readers
63
Key Buttoncentralized
1 2 3 A
654 0
B987
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.4410)
Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):
0712Vdc
250 to 60ºC
130x128x18115x114x45130x128x33
43
Protection against knocks (IK):Power supply (V):Cons. (mA) without door release:Operating temperature:
1 2 3
4 5 6
7 8 9
A 0 B
Key button identifier (ref.2328).
CE
NT
RA
LIZ
ED
64
Specifications
City key button WG (ref.2315)
Installation
Identifiers
Access control reader whose operation is based onphysical contact between the reader head andauthorized identifier (ref.2328).Number of users:- 1.020 users with MDS central unit (ref.2405).- 2.048 users with CAC central unit (ref.4410).Manufactured in aluminium.Flush or surface mounted.Recommended for interiors and exteriors.Door controller (ref.4420) required for operation.
twistedpairReader
2 wires
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.2405 or 4410)
2 wires
twistedpair
Up to 64 Central Units
2 wires
twistedpairReader
Up to 32 readers
Reader
2 wires
twistedpair
twis
ted
pair
........ ........
Power supply 12 Vdc
1 2 3
4 5 6
7 8 9
A 0 B
Up to 32 readersUp to 32 readers
7 wires
2 wires
Key Button WGcentralized
1 2 3 A
654 0
B987
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.4410)
Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):
0712Vdc
300 to 60ºC
130x128x18115x114x45130x128x33
43
Protection against knocks (IK):Power supply (V):Cons. (mA) without door release:Operating temperature:
Programmation Programming from PC software corresponding to installed
Central Unit (ref.2405 or ref.4410).
Technical features Output in Wiegand-26 bit or Dataclock format.
Wiegand (WG) readers let you equip the access control
installation with anti-sabotage security, as neither the door
opening mechanism nor the exit button connection are
built-in. These functions are supported by door controller
(ref.4420).
The reader can be used with other door controllers using
Wiegand-26 or Dataclock protocols.
Key button identifier (ref.2328).
Door controller(ref.4420)
1 2 3
4 5 6
7 8 9
A 0 B
7 wires
CE
NT
RA
LIZ
ED
Bruto key button MDS (ref.2554)
Specifications
Identifiers
Access control reader whose operation is based on physicalcontact between the reader head and authorized identifier(ref.2328).Vandal-proof panel.Manufactured in aluminium.Flush or surface mounted.Reader and controller integrated in the same module.Recommended for interiors and exteriors.Ideal for troubled zones or districts, offices, banks, etc.No door controller required (ref.4420).
Technical features Exit pushbutton input, door sensor input and electric lock
relay.
2-wire cables for power supply and twisted pair for data.
Dip switch to encode door number and electric lock activation
timing.
Requires external relay (ref.2013) if activating electric lock
with consumption over 500mA, inverted function or external
device (motor, barrier).
Programming from PC software corresponding to Central
Unit installed (ref.2405 or ref.4410).Programmation
Installation
2 wires
twistedpairReader
2 wires
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.2405 or 4410)
2 wires
twistedpair
Up to 64 Central Units
2 wires
twistedpairReader
Up to 32 readers
Reader
2 wires
twistedpair
twis
ted
pair
........ ........
Power supply 12 Vdc
1 2 3
4 5 6
7 8 9
A 0 B
Up to 32 readersUp to 32 readers
65
Key Buttoncentralized
1 2 3 A
654 0
B987
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref.4410)
Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):
0912Vdc
250 to 60ºC
135x130x18115x100x45135x131x42
53
Protection against knocks (IK):Power supply (V):Cons. (mA) without door release:Operating temperature:
Key button identifier (ref.2328).
1 2 3
4 5 6
7 8 9
A 0 B
CE
NT
RA
LIZ
ED
66
Unique and exclusive code per emitter.
Includes 12Vdc battery.
Range: 30m.
Frequency: 433,92 MHz.
Consumption in transmission: 10mA
Consumption in standby: 0.1mA
Technical features
Specifications Dimensions (WxHxDmm): 53x42x12mm
Compatible with Ref.7960 Villa Receiver (stand-alone).
Ref.1065 MDS Receiver (centralized).
Ref.2464 Secondary MDS Receiver (centralized).
Power supply 12 Vdc
twisted pair
Radiofrequencycentralized
Radio frequency emitter 433,92 MHz.Digital Technology.New and highly robust design.Dual channel emitter that can trigger two relays.Secure, unique, non configurable code exclusiveseries per emitter.Emitters must be authorized/cancelled in the receivers.
Digital RF emitter (ref.24651)
Installation
RF emitterref. 24651
Central Unitref.4410
RF Receiverref. 1065
2
CE
NT
RA
LIZ
ED
Specifications Dimensions (WxHxDmm): 53x36x13mm
Compatible with Ref.7960 Villa Receiver (stand-alone).
Ref.1065 MDS Receiver (centralized).
Ref.2464 Secondary MDS Receiver (centralized).
Power supply 12 Vdc
twisted pair
67
In addition to the RF functions, incorporates proximity
card electronics for use in proximity reader.
Includes 12Vdc battery.
Range: 30m.
Proximity reader range: 2 cm.
Frequency: 433,92 MHz.
Consumption in transmission: 10mA
Consumption in standby: 0.1mA
Technical features
Radio frequency emitter 433,92 MHz.Dual technology.New and highly robust design.Dual channel emitter that can trigger two relays.Secure code, unique, non configurable and exclusiveas standard per emitter.Emitters must be authorized/cancelled in the receivers.Internally integrates proximity card electronics so canbe used as a dual channel emitter or a substituteidenti f ier for proximity cards or keyrings.
RF Dual emitter (ref.25511)
Radiofrequencycentralized
Central Unitref.4410
2Installation
RF emitterref.25511
RF receiverref.1065
CE
NT
RA
LIZ
ED
68
Specifications Dimensions (WxHxDmm): 90x165x55mm
Includes rigid antenna, 25 cm.
Optionally, by adding card (ref.7934), we can convert
the receiver into dual channel.
Reception frequency: 433,92 MHz.
Sensitivity: 3 mV
Relay contact: 2 A max.
Power supply: 12Vdc
Consumption: 110 mA in standby.
Dip-switch to configure access number.
Technical features
2 wires
twisted pair
Central Unit(ref.2440 or 2405)
2 wires
twisted pair
Receiver
Up to 64 Central Units
2 wires
twisted pair
Up to 32 readers
2 wires
twisted pair
twis
ted
pair
Power supply 12Vdc
Video panel Reader
1 2 3
4 5 6
7 8 9
A 0 B
1 2 3
4 5 6
7 8 9
A 0 B........
Up to 32 readers
1 2 3
4 5 6
7 8 9
A 0 B........
Up to 32 readers
Single channel receiver 433.92MHzDigital Technology.When code emitted by the digital (ref.24651) ordual (ref.25511) remote control is received, thereceiver closes the circuit activating the electriclock or automatic door.Mounted in watertight box (IP65) in ABS.
MDS Receiver (ref.1065)
Radiofrequencycentralized
Compatible with Digital emitters (ref.24651)
Dual emitters (ref.25511)
Emitter RFRef.79561
2 wires
1 2 3
4 5 6
7 8 9
A 0 B
1 2 3
4 5 6
7 8 9
A 0 B
twis
ted
pai
r
Door Controller(ref.4420)
CE
NT
RA
LIZ
ED
Specifications Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):
4307
0 to 60ºC
130x128x18115x114x45130x128x33
Environmental protection (IP):Protection against knocks (IK):Operating temperature:
City Fingerprint WG (ref.6990)
Installation
Technical features
Programmation Programming from PC software corresponding to Central
Unit installed (ref.2405 or ref.4410).
twisted pair
Central Unit(ref.2405 or ref.4410)
2 wires
twisted pair
Reader
Up to 64 Central Units
2 wires
twisted pair
Up to 32 readers
2 wires
twisted pair
Power supply 12Vdc
Video panel Audio panel
1 2 3
4 5 6
7 8 9
A 0 B........
Up to 32 readers
1 2 3
4 5 6
7 8 9
A 0 B........
Up to 32 readers
2 wires
69
Fingerprint WGcentralized
Fingerprint reader with thermal sensor withstorage capacity:- 1.020 users with MDS central unit (ref. 2405).- 2.048 users with CAC central unit (ref.4410).Operating mode: 1 or 2 fingerprints per person.Manufactured in aluminium in new City style.Flush or surface mounted.Recommended for interiors and exteriors.Reader and controller separated.Door controller required (ref.4420).
1 2 3 A
654 0
B987
Output in Wiegand-26 bit or Dataclock format.
Wiegand (WG) readers let you equip the access control
installation with anti-sabotage security, as neither the door
opening mechanism nor the exit button connection are built-
in. These functions are supported by door controller (ref.4420).
The reader can be used with other door controllers using
Wiegand-26 or Dataclock protocols.
2 status signal LEDs: door open/closed.
Display 7 3-digit segments.
Infrared receiver for programming.
Programmable relay timings (monostable, bistable).
2 wires
1 2 3
4 5 6
7 8 9
A 0 B
1 2 3
4 5 6
7 8 9
A 0 B
7 wires
CE
NT
RA
LIZ
ED
70
Programmation Programming from PC software corresponding to installed
Central Unit (ref. 2405 or ref. 4410).
The audio or video door entry panel is located on the
outside. It is possible to set up a configuration in the
panel intuitively including a reader (ref.6989) for greater
security and more convenient access.
Installation
Specifications Environmental Protection (IP):Protection against knocks (IK):Power supply (V):
6/602A (NA,NC)
0 to 60ºC
4307
12Vdc
Cons. (mA) without door release:Relay contact:Operating temperature:
Output in Wiegand-26 bit or Dataclock format.
Wiegand (WG) readers let you equip the access control
installation with anti-sabotage security, as neither the
door opening mechanism nor the exit button connection
are built-in. These functions are supported by door
controller (ref.4420).
The reader can be used with other door controllers using
Wiegand-26 or Dataclock protocols.
2 status signal LEDs: door open/closed.
Display 7 3-digit segments.
Infrared receiver for programming.
Programmable relay timings (monostable, bistable).
Technical features
City fingerprint module WG (ref.6989)
Fingerprint reader with thermal sensor with storagecapacity:- 1.020 users with MDS central unit (ref. 2405).- 2.048 users with CAC central unit (ref.4420).Fitted in CityMax audio or video door entry systemoutdoor panel spare spaces for enhanced security inthe home.Door controller (ref. 4420) required for operation.
Fingerprint WGcentralized
2 wires
twisted pair
Central Unit(ref.2405 or ref.4410)
2 wires
twisted pair
Reader
Up to 64 Central Units
2 wires
twisted pair
Up to 32 elements
2 wires
twisted pair
twis
ted
pair
Power supply 12Vdc
Video panel Reader
1 2 3
4 5 6
7 8 9
A 0 B........
Up to 32 readers
1 2 3
4 5 6
7 8 9
A 0 B........
Up to 32 readers
2 wires
1 2 3
4 5 6
7 8 9
A 0 B
1 2 3
4 5 6
7 8 9
A 0 B
Central Unit(ref. 4410 or ref.2405)
2 wires
twisted pair
Reader
Up to 64 Central Units
2 wires
twisted pair
Up to 32 readers
2 wires
twistedpair
twis
ted
pai
r
Power supply 12Vdc
Video panel Reader
1 2 3
4 5 6
7 8 9
A 0 B........
Up to 32 readers
1 2 3
4 5 6
7 8 9
A 0 B........
Up to 32 readers
2 wires
1 2 3
4 5 6
7 8 9
A 0 B
1 2 3
4 5 6
7 8 9
A 0 B
Door Controller(ref.4420)
1 2 3
4 5 6
7 8 9
A 0 B
2 wires
CE
NT
RA
LIZ
ED
Programmation Programming from PC software corresponding to installed
Central Unit (ref.2405 or ref.4410). Card programmer
(ref.4460) required to memorize fingerprint samples in
the Mifare cards.
Installation
Specifications Power supply (V): 12Vdc
Dual technology: fingerprint and Mifare proximity card.
The reader compares the fingerprint stored in the card
and the sample read by the sensor.
Power supply 12Vdc.
2-wire cables for power supply and twisted pair for data.
One Mifare card (ref.4440) required for each user.
Technical features
Identificadores Mifare card with memory (ref.4440).
twisted pair
71
Fingerprint Readercentralized
Fingerprint (ref.4470)
Fingerprint reader with optical sensor and capacity tostore:- 1.020 users with MDS central unit (ref.2405).- 2.048 users with CAC central unit (ref.4410).Surface mounted for interiors.Door controller (ref.4420) required for operation.
7 wires
Accessories common to all systems.
A c c e s s o r i e s
cent
raliz
ado
AC
CE
SS
OR
IES
E lec tr ic Lock
Device that lets you unblock the door temporarily in safe conditions: identifier accepted or opening from inside bymeans of the exit button. There are several models distinguished by different operating features, installation and powersupply.Depending on the type of protection against electrical power cuts:Normal operation (fail secure). The door is unblocked when the electric lock is powered. As an advantage, if there isa power cut the door does not unlock. The NO (normally open) terminal is connected from the electric lock relay.Inverted operation (fai l safe). The door remains blocked while the electric lock is powered.It is unlocked by cutting off the power. An advantage is that if there is a power cut, the door does not block (firesystems).According to the type of installation, there are:Electrical lock/door release. Recommended in installations where we want to combine with the traditional lock andare normally installed embedded in the door frame. When activated, releases the latch to allow the door to open.Electromagnetic door release. Usually installed when there are security requirements against fire: outward openingdoors, power shutoff during the f ire alarm to faci l i tate evacuation. They are inverted type.An iron strip is placed in the leaf of the door and an electromagnet in the frame so that when the door is closed theirfaces are touching. The door stays closed while the electromagnet attracts the strip.Depending on the force with of attraction, it can resist pulling or pushing to try to open the door.The force is usually measured in Kg. When there is no space in the door frame to fit the lock or if we do not want todrill it, it can be mounted on the wall with special brackets.According to the type of power supply, there are:DC current. Characterized by being quiet. Inverted operation electric locks must be this type.AC current. They are noisy compared with DC locks. They generally have a higher consumption and work better indoors subject to some type of pressure: wind, bolt friction, etc.There are door release models with a built-in door sensor to detect if the door stays open accidentally.
74
Squares for emagnetics
door lock:
- For doors that open from inside to outside. ref.3077 Square for ref.3051
ref.3079 Doble square Z
- For doors that open from outside to inside. ref.3078 Square for ref. 3052
Accessoriesstand-alone/stand-alone in network/centralized
ref. Electr
iceM
agne
tic
3071 E N 12Vac 780 21x75x27 -40 a +120ºC E2953 E N 12Vac 780 • 20x101x28 -40 a +120ºC E2958 E N 12Vdc 150 20x101x28 -40 a +120ºC E29580 E N 12Vdc 150 • 20x101x28 -40 a +120ºC E2967 E I 12Vdc 150 20x101x28 -40 a +120ºC E29670 E I 12Vdc 150 • 20x101x28 -40 a +120ºC E3050 M 500
300Kg I 12/24 Vdc 250 229x39x26 -40 a +120ºC E3051 M 500
500Kg I 12/24 Vdc 250 229x39x26 -40 a +120ºC S3052 M 500
300Kg I 12/24 Vdc 250 229x39x26 -40 a +120ºC S
Normal
Invert
ed
Power
supp
ly
Door s
enso
r
Dimen
sions
Operat
ing te
mperat
ureFlu
shSu
rface
Consu
mption
(mA)
AC
CE
SS
OR
IES
Power Suppl ies
75
Accessoriesstand-alone/stand-alone in network/centralized
When choosing a suitable power supply it is necessary to consider the consumption of all the elements in the system,especially the electric lock. It is recommended to use a magneto-thermal switch not shared with any other equipmentto avoid power supply disconnections caused by them.
It is recommendable to use an emergency supply system (with battery) to prevent doors blocking or unblocking in theevent of power cuts. In centralized installations with long distances it will be necessary to place additional power sourcesin the access to prevent tension drops in the wiring.
REF. 4800 POWER SUPPLY 12VAC/1,5ARecommended for stand-alone readers when we want touse AC locks. DIN4.
REF. 8791 EMERGENCY POWER SUPPLY 12Vac/1,5AIncludes Ni-Cd battery 750mA. In emergency supplies12Vdc.Includes Ni-Cd battery 750mA. In emergency supplies12Vdc.
REF. 4813 POWER SUPPLY 12VDC/2AGeneral installation power supply for centralized system.
REF. 2060 BATTERY ADAPTER 12VDCInstalled between 12Vdc power supply and the system.With externa l Lead-Acid bat tery connect ion.If the input tension falls below 11Vdc it switches automaticallyto the battery.
REF. 2070 BATTERY 12V/2,2A Lead-Acid battery without maintenance for small installationsor an access power supply.
REF. 2337 BATTERY 12V/ 7ALead-Acid battery without maintenance for large installations.
ref.4800
ref. 4813
ref.2060
cent
raliz
ado
AC
CE
SS
OR
IES
Door Sensor
Power Cutoff
Desktop Proximity Reader
76
Accessoriesstand-alone/stand-alone in network/centralized
REF. 4475 POWER CUTOFFLets you disconnect the electrical current to the devices in a roomwhen the user is not in. For connection, it is necessary to introducethe user proximity card in the cutoff (only works with proximitycards). When the user leaves the room they remove the card fromthe cutoff and then have 10 seconds courtesy to leave the room.
Designed to be used as a complement to the stand-alone orcentralized proximity readers, since the same cards are used. Theuser is obliged to remove the card from the cutoff; otherwise theywill not be able to open the door of the room.
Embedded instal lat ion in mechanism box 60x70mm.Operating at 230V. Cutoff power: 6000W.
Proximity technology: EM, TEMIC, RF256 and TK cards.
REF. 1076 MAGNETIC CONTACTSurface installation between door and frame.
Connected to the door sensor input of the controllers.
Lets you authorize proximity identifiers quickly and easily by PCwith management software.PC connection: RS-232. Cable included.Power supply 230Vac by adaptor (included).
230Vac
3
RS-232
ref.2349
installation
power supply
AC
CE
SO
RIE
S
Accessoriesstand-alone in network/centralized
Adaptor RS-232 to RS-485 (ref.2338) Adaptor RS-232 to RS-485 (ref.2466)
77
The system operating mode configuration, user authorizations and cancellations and restrictions are handled via PC andsent to the central unit so that it works independently. The information generated by the installation (events) must becommunicated to the PC in real time. To set up these communications, the PC must be connected to the central unit.The connection can be made locally or remotely, using one of the following devices:
2
3
RS-232
ref. 2466
Connection between PC and central unit (or network ofCUs).Also lets you connect the modem to the central unit forremote management.PC connection: RS-232 max. 30 mts. (cable 3 mtrsincluded).Connection to central: RS-485 (twisted pair).Max. 1200 mts.DIN6 format (surface mounted and DIN rai l ) .Power supply 230Vac.
Programming of addresses and parameters to decodersfrom the PC.Used for maintenance of facilities that do not have thePC permanently connected, as an installer tool.Includes an RS-232 cable with DB-9 connector for PCconnection.
Adaptor USB to RS-485 (ref.24661)
Connection between PC (USB) and central unit.Direct power supply from USB.Includes driver.
IP Adaptor (ref.1087)
Communication between management PC and theinstallation using IT network (Ethernet), avoiding additionalwiring.Connection to central unit by programmer (ref. 2466).An IP address must be configured to connect to thenetwork using the software included.Remote management via Internet if the protection devices(Firewall) in the IT installation allow it (specialized personnelrequired to configure router for Internet access).
Power supply 230Vac by adaptor included.Ethernet connection RJ45.
2
3
RS-485
RS-232
230 Vac
ref.2338
PC Management Modules
twisted pair
twisted pair
2 RS-485
USB
PC
Ref.24661
twisted pair
2
3
RS-232
ref. 2466
IP
ref.1087
RJ-45 RJ-45
PC
twisted pair
2
cent
raliz
ado
AC
CE
SS
OR
IES
In the installation it is possible to connect up to 1000 relays in the same decoder bus, to activate different devices in
response to the activation of sensors or trigger them independently. The relays are implemented by 'relay decoder'
containing 8 2 Amp. relays with NA and NC output. The relay decoder connects to the decoder bus, which powers it.
For each output, timing (1 to 255 seconds or indefinite) and the initial status (active or standby) are configured.
78
Accessoriescentralized
Several sensors may be connected to the installation (up to 1000) to carry out automated activities based on the sourceof the detection. The sensors must be potential free contact, such as switches, pushbuttons, magnetic contacts,volumetric detectors, photoelectric barriers, etc.
These sensors are managed by 'sensor decoders’, with capacity for 8 entrances, and connected to the central unit bythe decoder bus, from which it is powered.NA or NC operating mode and the type of trigger (instant or delay up to 127 minutes) must be configured.
For each group (100 sensors), the actions to take are indicated (not exclusive):
Communicate the incident to the central console (security post).
Activate one or several relays (ref. 2430) (always the same or different depending on the sensor).
Switch status of a relay.
Monitor the incident on the control computer (control post).
Activate the electric lock of a given door.
Subordinate the action to the simultaneous activation of another sensor (double signalling to avoid false alarms).
Sensors can be enabled and disabled during a set schedule by means of the schedule planner or from the
access control readers, when a user identi f ier associated with a sensor is presented.
The most frequent applications of the sensors are the following:
Technical alarms: Alarm messages in the PC control. Power failure, water leak, intrusion, etc...
Construction of pushbutton panels for timed activation of devices: vehicle barriers, opening doors, hallway
lighting, etc.
Door blocking depending on the status of other doors.
SENSOR DECODER ref.2429
RELAY DECODER ref.2430
Technical Alarms and Automation
AC
CE
SS
OR
IES
There are several ways to trigger the relays:
Specifications
79
ref.5918
ref.2537
Automatic connection and disconnection of devices: heating,refrigeration, lighting, etc.Alarms connection and disconnection.Activation of sirens and warning lights.Unblocking of doors during a set schedule.
Schedule planner: activates and deactivates relays according to a set weekly schedule (up to 32 daily plans).From the access control readers. Each user can have a relay associate with their identifier so that when it is presented,the associated relay status is switched while activating the door release.From the central guard - unit. Any relay can be activated or deactivated by entering its number and the desired status(active / standby).When a sensor or combination of sensors is activated.When the maximum capacity of a zone is reached.When there is someone in a zone.
Typical applications are:
Programming the sensor and relay decoders is done with thedecoder programmer (ref. 2466).
Dimensions (WxHxDmm):Nº devicesMaximum capacity/centralActivation typeProg. detection/activationDetection/activation.Power supplyConsumption (mA) min/max.Temperature operating:
175x90x378 outputs
2 A NC/NA1 sec.
1..255 sec./indefinite
7/170-10ºC to +60ºC
175x90x378 inputs
Potential free contact26 sec.
1sec./127 min.
10-10ºC to +60ºC
1000
12Vdc
SENSOR DECODER RELAY DECODER
De s k t o p guard un i t
Can recieve calls from the interphone panels and allow accessto visitors. Permits access management of any door within theinstallation. Receives sensor reports in the case of manipulatedor open doors.
In installations with several guard units all calls and alarms canbe centralized in one main guard unit. To be connected to thedoor bus by means of two additional wires for the audio(ref.5918).
From the main guard unit a simple user configuration can bedone (without restrictions), no PC configuration necessary.
Dimensions (WxHxDmm):Power supply:Consumption (mA) min/max.:Operating temperature:
215x205x25012 Vdc
300-10ºC to +60ºC
175x90x3712 Vdc15/30
-10ºC to +60ºC
PANEL DECODER MAIN GUARD UNIT
80
RF MDS RECEIVER
REMOTE MANAGEMENT IP MODULE
RELAY STAIRS LIGHT
EMERGENCY BATTERY MODULE 12V
EMERGENCY BATTERY 12V-2 A.
BRUTO KIT MEMOKEY STAND-ALONE
CITY KIT PRIVATE STAND-ALONE
CITY PROXIMITY READER STAND-ALONE MODULE
BRUTO PROXIMITY MDS MODULE
BRUTO PROXIMITY READER STAND-ALONE MODULE
PROGRAMMATION KEYPAD PRIVATE READER
KEY-BUTTON READER WG
KEY BUTTON IDENTIFICATOR
PROXIMITY CARD WITH MAGNETIC STRIPE
BATTERY 12VDC.6,5AMP
DIN TERMINAL DIG.FX-L 220V
CITY PRIVATE READER STAND-ALONE
CITY PRIVATE READER DESKTOP
PROGRAMMING KIT WINPROX
PROXIMITY CARD WITHOUT MAGNETIC STRIPE
CENTRAL UNIT MDS
DECODER OF 8 SENSORS MDS
DECODER OF 8 RELAYS MDS
SECUNDARY RF RECEIVER
PC INTERFACE DECODER
CITYMAX MEMOKEY MODULE
BRUTO MEMOKEY MODULE
BRUTO PROXIMITY READER MDS
BRUTO MDS DIGITAL KEYPAD
BRUTO KEY-BUTTON READER MDS
CITY PROXIMITY MDS MODULE
CITY KEYPAD MDS MODULE
BRUTO 1 SURFACE BOX MODULE
DOOR LOCK MOD.3000N-S
DOOR LOCK N-412-S
DOOR LOCK N-512-S
FLUSH EMAGNETIC DOOR LOCK 300Kg
EMAGNETIC SURFACE DOOR LOCK 500Kg
EMAGNETIC SURFACE DOOR LOCK 300Kg
UNIVERSAL MOD.450N-S DOOR LOCK
SQUARE L-2 FOR REF.3051
SQUARE L-3 FOR REF.3052
DOUBLE SQUARE
REF. DESCRIPTION
01065
01087
02013
02060
02070
02133
02260
02263
02268
02288
02306
02315
02328
02336
02337
02338
02347
02349
02351
02363
02405
02429
02430
02464
02466
02520
02523
02552
02553
02554
02560
02561
02778
02953
02958
02967
03050
03051
03052
03071
03077
03078
03079
Index of references
81
CITY MEMOKEY CR 230V KIT
DIN RAIL 12 VDC 12A RELAY
KIT MEMOKEY CITY STAND-ALONE
CITY MEMOKEY READER STAND-ALONE
CITY PRIVATE KIT WITH PROXIMITY KEYRINGS
CR MEMOKEY 100 CODES KEYPAD
CR MEMOKEY 100C. CONTROLLER
LOFT MEMOKEY STAND-ALONE KIT
KIT PRIVATE LOFT STAND-ALONE
CAC CENTRAL UNIT
DOOR CONTROLLER WITHOUT MEMORY
MIFARE PROXIMITY CARD
FINGERPRINT PROGRAMMER
FINGERPRINT READER
ENERGY CUTOFF
CITYMAX BLUETOOTH MODULE
CITY BLUETOOTH READER
BLUETOOTH READER KIT
CITY MEMOKEY/PROXIMITY WG
CITY PROXIMITY READER WG
BRUTO MEMOKEY MODULE
BRUTO PROXIMITY READER WG
BRUTO 1 PRIVATE MODULE
LOFT PROXIMITY READER STAND-ALONE
LOFT MEMOKEY READER STAND-ALONE
LOFT MEMOKEY/PRIVATE READER WG
LOFT PRIVATE READER WG
MARINE FLUSH BOX ST-2
MARINE PROXIMITY READER MODULE STAND-ALONE
MARINE MEMOKEY KEYPAD
POWER SUPPLY 12VAC/1,5A
POWER SUPPLY DIN10 230VAC/12VAC+18VDC-1.5A
POWER SUPPLY 12VDC/2A
CITY FINGERPRINT READER KIT
CITY FINGERPRINT MODULER READER
CITY FINGERPRINT READER
SINGLE CHANNEL 433Mhz RF RECEIVER
RF RECEIVER FOR SHOPS 433Mhz - 230 V
RADIOFRECUENCY FOR SHOPS KIT
STANDARD RADIOFRECUENCY KIT
SECURITY RADIOFRECUENCY KIT
RF RECEIVER FOR GARAGES
RF VILLA RECEIVER
REF. DESCRIPTION
03591
03491
03600
03610
03619
03620
03621
03623
03624
04410
04420
04440
04460
04470
04475
04476
04477
04478
04480
04490
04500
04510
04520
04530
04540
04550
04560
04642
04698
04699
04800
04810
04813
06988
06989
06990
07900
07903
07910
07911
07912
07952
07960
Index of references
82
EMERGENCY POWER SUPPLY 12VAC/1,5A
CITY SUPERFACE BOX SERIES 1
BRUTO KEYPAD MDS MODULE
MDS KEY BUTTON READER
CITY MEMOKEY READER MDS
CITY PRIVATE READER MDS
STANDARD PROXIMITY CARD WITHOUT MAGNETIC STRIPE
RF SEGURITY EMITTER
USB CONVERTER
RF DUAL EMITTER
DOOR LOCK AD-2005
DOOR LOCK MOD.N-424-S MAX
DOOR CONTROLLER WITH MEMORY
PROXIMITY KEYRING
RF TRINARY EMITTER
REF. DESCRIPTION
08791
08851
22371
23261
23291
23351
23361
24651
24661
25511
29518
29628
44201
44501
79561
Index of references
ACCESS CONTROL 1 st Edi t ion. March 2009