Introduction

•  Ultrasound biomicroscopy (UBM) provides high-resolution imaging of the anterior segment in a noninvasive fashion.

• In addition to the tissues easily seen using conventional methods (ie, slit lamp), such as the cornea, iris, and sclera, structures including the ciliary body and zonules, hidden from clinical observation, can be imaged and their morphology assessed.

• Pathophysiologic changes involving anterior segment architecture can be evaluated qualitatively and quantitatively.

Page 3: Ptosis

INTRODUCTION

• Recent technique to visualize anterior segment with the help of high frequency ultra sound transducer.

• UBM (anterior segment ultrasonography) is performed with a 50 Mhz probe.

• The resolution of 50 MHz probe is 40 microns and the depth is 4 mm

Page 4: Ptosis

• UBM is done with the patient in the supine position and the eye is open.

• Since the piezoelectric crystal of the transducer is open it should not come in direct contact with the eye to prevent injury to the cornea

Page 5: Ptosis
Page 6: Ptosis
Page 7: Ptosis
Page 8: Ptosis

• There is a special cup which fits in between the eyelids, keeping them open

• The eye cup is filled with saline or sterile methylcellulose.

• The crystal of the transducer is placed in saline approximately 2 mm from the eye surface.

(This distance of 2 mm prevents injury to the cornea and also helps as a fluid standoff.)

• The eye is scanned in each clock hour from the center of the cornea to the ora serrata

Page 9: Ptosis
Page 10: Ptosis

UBM AND CORNEAUBM AND CORNEA

Page 11: Ptosis
Page 12: Ptosis
Page 13: Ptosis

Graft host junction

Page 14: Ptosis

Corneal edema

Page 15: Ptosis

Corneal dystrophy

Corneal dystrophies can be imaged and the depth of pathology defined. Granular dystrophy shows highly reflective hyaline bodies in the superficial stroma.

Page 16: Ptosis

UBM AND GLAUCOMAUBM AND GLAUCOMA

Page 17: Ptosis
Page 18: Ptosis

Pupillary block glaucoma

Page 19: Ptosis

Plateau iris

Page 20: Ptosis

Indendation UBM

Page 21: Ptosis

Pigmentary glaucoma

Page 22: Ptosis

Malignant glaucoma

Page 23: Ptosis

UBM AND TUMORSUBM AND TUMORS

Page 24: Ptosis
Page 25: Ptosis

Choroidal tumor

Page 26: Ptosis

Ciliary body tumor

Page 27: Ptosis
Page 28: Ptosis
Page 29: Ptosis

Iridociliary cyst The most common clinical presentation of an irido-ciliary cyst is a peripheral iris elevation - the typical UBM finding of a thin walled structure with no internal reflectivity is diagnostic.

Page 30: Ptosis

UBM AND IOLUBM AND IOL

Page 31: Ptosis

IOL

Page 32: Ptosis

Haptics

Page 33: Ptosis

Dislocated IOL

Page 34: Ptosis

UBM AND SCLERAUBM AND SCLERA

Page 35: Ptosis

Normal sclera

Page 36: Ptosis

Episcleritis

Page 37: Ptosis

Scleritis Scleritis shows relatively low reflective regions within the sclera likely representing edema and inflammatory infiltrates

Page 38: Ptosis

UBM IN TRAUMAUBM IN TRAUMA

Page 39: Ptosis

Iridodialysis

Page 40: Ptosis

Cyclodialysis

Page 41: Ptosis

Zonular rupture

Page 42: Ptosis

Angle recessionAngle recession is imaged as a tear into the face of the ciliary body. Ciliary body tissue is still imaged attached to the scleral spur.

Page 43: Ptosis

Measurements

Page 44: Ptosis

Angle recess area

Page 45: Ptosis

Iris configuration

Page 46: Ptosis

• UBM is useful in opaque media• The most important limitation of UBM

is depth. UBM cannot visualize structures deeper more that 4 mm from the surface.

• The other limitation is that UBM cannot be performed in presence of an open corneal or scleral wound.

• It is time consuming

Page 47: Ptosis

AS OCT

Page 48: Ptosis

• Tomographic techniques generate slice images of three-dimensional objects.

• Optical tomographic techniques are of particular importance in the medical field, because these techniques can provide non-invasive diagnostic images

Page 49: Ptosis

• Optical coherence tomography is a non-contact, real-time technique that uses low infrared laser energy to image structures. 

Page 50: Ptosis

• Optical coherence tomography imaging is based on measuring the delay of light (typically infrared) reflected from tissue structures.

• Because light travels extremely fast, it is not possible to directly measure the delay at a micron resolution. Therefore, OCT employs low-coherence interferometry to compare the delay of tissue reflections against a reference reflection.

Page 51: Ptosis

• To obtain an OCT image, the instrument scans a light beam laterally, creating a series of axial scans (A-scans), after which it combines these A-scans into a composite image.

• Each A-scan contains information on the strength of reflected signal as a function of depth.

Page 52: Ptosis

• The more commonly used retinal OCT uses 820-nm light, which allows for excellent tissue penetration to the level of the retina.

• The anterior segment OCT utilizes 1310-nm light, which has greater absorption resulting in limited penetration. 

Page 53: Ptosis

• This allows for increased intensity of the light as decreased amounts reach the retina.

• The light is 20 times more intense, giving a much greater signal-to-noise ratio.

• This increased intensity allows for increasing the speed in imaging 20 times, with decreased motion artifact. 

Page 54: Ptosis

• Compared with other imaging modalities, OCT has a higher-depth resolution.

• Resolution is determined by the wavelength and the spectral bandwidth of the light source, Shorter wavelengths and wider bandwidths provide better resolution.

Page 55: Ptosis

Types of oct system

There are two principles of image acquisition and data processing in anterior segment OCT:

• Time domain and

• Fourier domain algorithms.

Page 56: Ptosis

• In time domain OCT, there is a mechanical moving part that performs the A-scan, Thus, the rate of the scan is limited by the movement of the part.

• In Fourier domain OCT, the information in an entire A-scan is acquired by a charge-coupled

device (CCD) camera simultaneously. As there is no mechanical movement, the scan time in Fourier domain OCT is faster. This is an important advancement because faster acquisition time means lesser variability in the result due to the patient’s eye movements.

Page 57: Ptosis

Scans • Anterior Segment Scan (16 x 6 mm)• Single, Dual or Quad lines• 256 A scans / .125 sec acquisition per line

• High Resolution Scan (10 x 3 mm)• Single or Quad• 512 A-scans / .25 sec acquisition per line

• Pachymetry Scan (10 x 3 mm)• 8 radial lines• 128 A scans / 0.5 sec total acquisition time

• All Scans adjustable in orientation and direction

Page 58: Ptosis
Page 59: Ptosis
Page 60: Ptosis

ASOCT AND ASOCT AND KERATOCONUSKERATOCONUS

Page 61: Ptosis

Keratoconus

I–S: -45IT–SN: -45Minimum: the thinnest corneal thickness: 470Minimum–maximum: -100

Page 62: Ptosis

AS OCT IN LASIKAS OCT IN LASIK

Page 63: Ptosis

Lasik flap evaluation

Page 64: Ptosis

Lasik flap evaluation

Page 65: Ptosis
Page 66: Ptosis

ASOCT IN AS ASOCT IN AS BIOMETRYBIOMETRY

Page 67: Ptosis

Anterior chamber biometry

Page 68: Ptosis

PHAKIC IOL

PRE OP PLANNING POST OP OBSERVATION

ACD PCIOL DEPTH AND CENTRATION

ANGLE TO ANGLE IRIS POSITION

ANTERIOR CHAMBER ANGLE CRYSTALLINE LENS VAULT

IRIS OR CRYSTALLINE LENS POSITION

ENDOTHELIAL SAFETY DISTANCE

ACCOMADITVE ANALYSIS ACCOMADITIVE ANALYSIS

Page 69: Ptosis

ASOCT AND ANGLEASOCT AND ANGLE

Page 70: Ptosis

Angle opening distance 329microns

Page 71: Ptosis
Page 72: Ptosis

Anterior chamber angle 28

Page 73: Ptosis

ASOCT IN ASOCT IN TRANSPLANTTRANSPLANT

Page 74: Ptosis

Penetrating keratoplasty

Page 75: Ptosis

Descemet-stripping endothelial keratoplasty

Page 76: Ptosis

ASOCT AND INTACSASOCT AND INTACS

Page 77: Ptosis

Intacs

Page 78: Ptosis

ASOCT AND CORNEAASOCT AND CORNEA

Page 79: Ptosis
Page 80: Ptosis
Page 81: Ptosis
Page 82: Ptosis
Page 83: Ptosis

Advantages of AS OCT

• Technicians can do the scanning• Imaging flexibility• Faster imaging reduces error• Image through an opaque cornea• It's easy to image accommodative

changes• Scans can be taken immediately

after surgery

Page 84: Ptosis

Limitations

• Pigmentation on the posterior side of the iris blocks the penetration of infrared light.

• Trabecular meshwork/ ciliary body not seen

• Manual angle measurement

Page 85: Ptosis
Page 86: Ptosis

blepharoptosis

Dr.Dhivya pratheepa

Page 87: Ptosis

Blepharoptosis • Greek word : to fall• Is abnormal infero displacement of

upper eye lid

Page 88: Ptosis

classificaton

Page 89: Ptosis

classification

Neurogenic

• Third nerve palsy • Horner’s syndrome

Myogenic

• Myasthenia gravis• Myotonic dystrophy• OPMD• CPEO

Page 90: Ptosis

classification

Aponeurotic

• Involutional • Post operative

Mechanical

• Tumor • Dermatochalasis • Oedema • Scarring

Page 91: Ptosis

pseudoptosis

• Microphthalmous • Pthisis bulbi• Double elevator

palsy• Blepharospasm• Contralateral

proptosis• Enopthalmous

Page 92: Ptosis

History

• History of present illness • Associated history• Past history • Family history

Page 93: Ptosis

History

• History of present illness :age of onset

• Associated history duration• Past history one/both

eye• Family history variability

Page 94: Ptosis

History

• History of present illness • Associated history : diplopia • Past history odynophagia• Family history muscle

weakness cardiac problem night blindness

Page 95: Ptosis

History

• History of present illness • Associated history• Past history : trauma/ surgery • Family history contact lens lid edema allergy dry eyes

Page 96: Ptosis

History

• History of present illness • Associated history• Past history • Family history

Page 97: Ptosis

evaluation of ptosis

• head posture,Eyebrow position, eyelid masses, inflammation, proptosis

• pupillary size, reaction, heterochromia

• Best corrected Visual Acuity: In infants, make sure infant can fix and follow light with each eye

• Cycloplegic Refraction

Page 98: Ptosis

evaluation of ptosis• Strabismus Evaluation• Extraocular Muscles Motility: Note

paresis, paralysis of muscles• Bell’s phenomenon • Jaw-Winking Phenomena Evaluation• Corneal Sensitivity• Schirmer’s Test• Funduscopic Examination : Abnormal

retinal pigmentation

Page 99: Ptosis

Bell’s phenomenon

Page 100: Ptosis

evaluation of ptosis• Strabismus Evaluation• Extraocular Muscles Motility: Note

paresis, paralysis of muscles• Bell’s phenomenon • Jaw-Winking Phenomena • Corneal Sensitivity• Schirmer’s Test• Funduscopic Examination : Abnormal

retinal pigmentation

Page 101: Ptosis

Marcus gunn jaw winking phenomenon

Page 102: Ptosis

evaluation of ptosis• Strabismus Evaluation• Extraocular Muscles Motility: Note

paresis, paralysis of muscles• Bell’s phenomenon • Jaw-Winking Phenomena • Corneal Sensitivity• Schirmer’s Test• Funduscopic Examination : Abnormal

retinal pigmentation

Page 103: Ptosis

In children

• Presence or absence of Lid fold • Head tilt• Iliff test

Page 104: Ptosis

Measurements

• Vertical fissure height• Margin reflex distance• LPS action• Lid crease level• Lid level on down gaze

Page 105: Ptosis

Vertical fissure height

• The distance between the upper and lower eyelid in vertical alignment with the center of the pupil in primary gaze, with the patient’s brow relaxed.

• Normal – 9-10mm in primary gaze• Should be seen in up gaze, down gaze and

primary gaze• Amount of ptosis = difference in palpebral

apertures in unilateral ptosis or Difference from normal in bilateral ptosis

Page 106: Ptosis
Page 107: Ptosis

Grading of severity of ptosis

< or = 2mm : mild ptosis= 3 mm : moderate ptosis= or > 4 mm : severe ptosis

Page 108: Ptosis

MRD• Margin-to-reflex distance 1 (MRD1) : is the

distance from the central pupillary light reflex to the upper eyelid margin with the eye in primary gaze.

• A measurement of 4 - 5 mm is considered normal.

• If the margin is above the light reflex the MRD 1 is a +ve value.

• If the lid margin is below the corneal reflex in cases of very severe ptosis the MRD 1 would be a –ve value. 

Page 109: Ptosis
Page 110: Ptosis

MRD

• Margin-to-reflex distance 2 (MRD2) : is the distance from the central pupillary light reflex to the lower eyelid margin with the eye in primary gaze. . 

• The MRD1 plus the MRD2 should equal the palpebral fissure measurement

Page 111: Ptosis

Levetor function

•  is the distance the eyelid travel from downgaze to upgaze while the frontalis muscle is held inactive at the brow.

• The normal levator function is between 13-17mm

Page 112: Ptosis

• Lid excursion is a measure of the levator function. The frontalis action is blocked by keeping the thumb tightly over the upper brow and asking the patient to look up from down gaze and measuring the amount of upper lid excursion at the center of the lid.

Page 113: Ptosis

Berkes method

Page 114: Ptosis

Grading of levator action

< 4mm – poor levator function5-7 mm – fair levator function8-12 mm – good levtor function

Page 115: Ptosis

Lid crease

• Position is the distance from the crease to lid margin

• Normal – 8 to 10mm in primary gaze• An absent lid crease is often accompanied

by poor levator function. • If a lid crease is present but is higher than

normal and if a deeper upper lid sulcus is found on that side, note these as signs of a levator aponeurosis disinsertion.

Page 116: Ptosis
Page 117: Ptosis

Phenyl ephrine test

• Patients with minimal ptosis (2 mm or less) should have a phenylephrine test performed in the involved eye or eyes

•   Either 2.5 or 10% phenylephrine is instilled in the affected eye or eyes.  Usually two drops are placed and the patient is reexamined 5 minutes later. 

• The MRD1 is rechecked in the affected and unaffected eyes .

• A rise in the MRDl of 1.5 mm or greater is considered a positive test.  This indicates that Müller's muscle is viable

Page 118: Ptosis

Ice test

Page 119: Ptosis

Investigation

• Serum acetylcholine receptor assay• Tensilon test• EMG• ECG• ERG• T3, T4, TSH

Page 120: Ptosis

Surgical management

• Wait till 3-4 years of age• Pupil covered operate immeditely

Page 121: Ptosis
Page 122: Ptosis