Prubas de vacio para southern peru

1
Vacuum Test for the Tank Bottom Plate We will specify the location of the opening through which bubbles are vacuumed, by applying bubbles to the flange parts etc. and conducting suction from the lower side of the bottom plate. On September 20, vacuum test for the tank bottom plate was conducted, and we found leak from caulking and mortar installed around the bottom-plate (in-leak), therefore we found no bubble suction. On September 25, after treating the accumulated water under the tank bottom plate, and re-conducting sealing, we found the two adjacent bolts through which bubbles were vacuumed up. We continue the investigation into leakage. Bottom plate Side plate Inside Outside Bottom-plate flange parts Bottom-plate reinforcement member Suction from the lower side of the bottom plate (0.03MPa) Bottom plate Bottom plate Water-expandable waterproof material Water-expandable sealing material Sealing material Concrete foundation Concrete foundation Sealing* Suction from the lower side of the bottom plate Bubbles Bubbles are vacuumed up through an opening. Sealing *We replaced caulking and mortar with sealing of water-proof tapes 180° 90° 270° 0° Bubble suction was found here. <Reference> September 25, 2013 Tokyo Electric Power Company Bolts where bubble suction was found. Approx. 10 m Approx. 12m

description

Pruebas de vacio para southern Peru

Transcript of Prubas de vacio para southern peru

  • Vacuum Test for the Tank Bottom PlateWe will specify the location of the opening through which bubbles are vacuumed, by applying bubbles to the

    flange parts etc. and conducting suction from the lower side of the bottom plate.On September 20, vacuum test for the tank bottom plate was conducted, and we found leak from caulking

    and mortar installed around the bottom-plate (in-leak), therefore we found no bubble suction.On September 25, after treating the accumulated water under the tank bottom plate, and re-conducting

    sealing, we found the two adjacent bolts through which bubbles were vacuumed up.We continue the investigation into leakage.

    Bottom plate

    Side plate

    Inside Outside

    Bottom-plate flange partsBottom-plate reinforcement member

    Suction from the lower side of the

    bottom plate(0.03MPa)

    Bottom plateBottom plate

    Water-expandable waterproof materialWater-expandable sealing materialSealing material

    Concrete foundation Concrete foundation

    Sealing*

    Suction from the lower side of the bottom plate

    Bubbles

    Bubbles are vacuumed up through an opening.

    Sealing

    *We replaced caulking and mortar with sealing of water-proof tapes

    180

    90270

    0

    Bubble suction was found here.

    September 25, 2013

    Tokyo Electric Power Company

    Bolts where bubble suction was found.

    Approx.

    10m

    Approx. 12m