Page 1: Protecting personnel, property and · PDF fileRosemount™ 928 Wireless Gas Monitor with 628 series Hydrogen Sulfide Sensor ... Net Safety™ Air Particle Monitor ... FGD-BRO-Safety-Monitoring

Safety MonitoringFlame, gas, and particle detection solutions.

Protecting personnel, propertyand productivity.

Page 2: Protecting personnel, property and · PDF fileRosemount™ 928 Wireless Gas Monitor with 628 series Hydrogen Sulfide Sensor ... Net Safety™ Air Particle Monitor ... FGD-BRO-Safety-Monitoring

2

Introducing Emerson’s Full-Line of Flame& Gas Detection Solutions.

Your People and Facilities Come First!

That’s why Emerson is dedicated to offering the most comprehensive and advanced detection technologies available. Our flame and gas detection products are designed to help you streamline day-to-day operations and more importantly, keep your people safe – because if it matters to you, it matters to us.

Page 3: Protecting personnel, property and · PDF fileRosemount™ 928 Wireless Gas Monitor with 628 series Hydrogen Sulfide Sensor ... Net Safety™ Air Particle Monitor ... FGD-BRO-Safety-Monitoring

3

Rosemount™ Flame Detectors

975UR Ultraviolet InfraredSenses radiant energy in the short wave section of both the ultraviolet and infrared portions of the electromagnetic spectrum to detect hydrocarbon-based fuel and gas fires.

� Sensitivity Range: 1 ft2 (0.1 m2 ) n-heptane pan fire from 93 ft (28 m)

� Field of view: 100° Horizontal/95° Vertical

� Spectral Response: UV: 0.185–0.260 µm IR: 4.4–4.6 µm � Approvals: ATEX and IECEx, FM/FMC/CSA, EN54-10 (VdS), FM3260,

IEC61508 - SIL2 (TÜV)

975MR Multi-spectrum InfraredUtilizes three infrared bands to detect fuel and gas fires at long distances with the highest immunity to false alarms.

� Detect a 1 ft2 (0.1 m2) gasoline pan fire at 215 ft (65 m) in less than 5 seconds

� Field of view: 100° Horizontal/95° Vertical

� Spectral Response: Three IR Bands

� Approvals: ATEX and IECEx, FM/FMC/CSA, EN54-10 (VdS), FM3260, IEC61508 - SIL 2 (TÜV)

975HR Multi-spectrum Infrared HydrogenSpecifically designed for detection of hydrocarbon and hydrogen flames. Detects hydrocarbon and hydrogen based fuel and gas fires at long distances with the highest immunity to false alarms.

� Detect a gasoline pan fire at 215 ft (65 m) or a hydrogen fire at 125 ft (38 m) in less than 5 seconds

� Field of view: 67° Horizontal/70° Vertical for Gasoline 80° Horizontal/80° Vertical for Hydrogen

� Spectral Response: Multi IR Bands

� Approvals: ATEX and IECEx, FM, FMC/CSA, EN54-10 (VdS), FM3260, IEC61508 - SIL 2 (TÜV)

975UF Ultra Fast Ultraviolet InfraredSpecifically designed to meet two major requirements: High-Speed Response (20 millisecond). High Reliability (immunity to false alarm). Detects hydrocarbon-based fuel and gas fires, hydroxyl and hydrogen fires, as well as metal and inorganic fires.

� High-Speed Response 20 msec to flash fire

� Field of view: 100° Horizontal/95° Vertical

� Spectral Response: UV: 0.185–0.260 µm IR: 2.5–3.0 µm

� Approvals: ATEX and IECEx, FM/FMC/CSA, EN54-10 (VdS), FM3260, IEC61508 - SIL 2 (TÜV)

Page 4: Protecting personnel, property and · PDF fileRosemount™ 928 Wireless Gas Monitor with 628 series Hydrogen Sulfide Sensor ... Net Safety™ Air Particle Monitor ... FGD-BRO-Safety-Monitoring

4

Wireless Gas Monitoring

Rosemount™ 928 Wireless Gas Monitor with 628 series Hydrogen Sulfide Sensor

Integrated WirelessHART® Gas Monitoring Technology

Continuously monitor for the presence of toxic hydrogen sulfide in remote and hard to reach locations.

� Hot-swappable electrochemical sensor can be installed in the field with one hand and no tools

� Intrinsically safe power module can be easily replaced, even in hazardous locations

� Operating Temperature: -40 °F to +122 °F (-40 °C to +50 °C)

� 2 + year battery life

� Seamlessy integrates into industry standard IEC 6251 WirelessHART networks

� Outputs: EC 62591 (WirelessHART) 2.4 GHz DSSS, Optional discrete output to support local alarming

� Approval: Intrinsically Safe, M/CSA Div 1 ANSI/ISA 92.00-2010 (R2015); ATEX/IECEx Zone 0

Emerson™ Wireless 775 THUM™ AdapterUnleash the full benefits of the Millennium II fixed Gas Detector and Sensors.

� Now available: Wireless THUM explosionproof certification for North America - USA (E5) and Canada (E6)

� Install directly on explosionproof Millennium II detectors without the need for a barrier

� Utilize with SC3 and ST3 series of combustible sensors for wireless gas detection

� Gain access to additonal HART information including diagnostics

� Standards based IEC 62591 WirelessHART® delivers reliable and secure communication

� Operating Temperature: -40 °F to 185 °F (-40 °C to 85 °C)

� Approval: FM, CSA, ATEX, IECEx

Page 5: Protecting personnel, property and · PDF fileRosemount™ 928 Wireless Gas Monitor with 628 series Hydrogen Sulfide Sensor ... Net Safety™ Air Particle Monitor ... FGD-BRO-Safety-Monitoring

5

Net Safety™ Point Gas Detectors

Millennium II Basic Single ChannelDesigned for demanding, industrial applications that require a local, full-featured transmitter interface but do not require a character display.

� Long range (+2,000 ft/600 m) sensor separation

� Operating Temperature: -67 °F to 185 °F (-55 °C to 85 °C)

� Bright LED indicators for Power/Alarm/Fault conditions

� Approvals: FM6320, ANSI/ISA 12.13.01, CSA 22.2 No. 152:2006, IECEx

Emerson™ Wireless 775 THUM™ AdapterUnleash the full benefits of the Millennium II fixed Gas Detector and Sensors.

� Now available: Wireless THUM explosionproof certification for North America - USA (E5) and Canada (E6)

� Install directly on explosionproof Millennium II detectors without the need for a barrier

� Utilize with SC3 and ST3 series of combustible sensors for wireless gas detection

� Gain access to additonal HART information including diagnostics

� Standards based IEC 62591 WirelessHART® delivers reliable and secure communication

� Operating Temperature: -40 °F to 185 °F (-40 °C to 85 °C)

� Approval: FM, CSA, ATEX, IECEx

Millennium II Dual ChannelDual channel capability allows for more coverage area with a single transmitter - mix and match both the SC3 and ST3 series of combustible and toxic gas sensors. Redefines what you expect from a fixed gas detection solution.

� One transmitter for two detection points

� Long range (+2,000 ft/600 m) sensor separation

� Operating Temperature: -67 °F to 185 °F (-55 °C to 85 °C)

� Full diagnostics with event and data logging of over 980 sequential events

� Approvals: FM6320, ANSI/ISA 12.13.01, CSA 22.2 No. 152:2006, IECEx

Millennium II Single ChannelSingle channel universal transmitter with a full character OLED display – compatible with both the SC3 and ST3 series of combustible and toxic gas sensors.

� Long range (+2,000 ft/600 m) sensor separation

� Operating Temperature: -67 °F to 185 °F (-55°C to 85°C)

� Full diagnostics with event and data logging of over 980 sequential events

� Approvals: FM6320, ANSI/ISA 12.13.01, CSA 22.2 No. 152:2006, IECEx

Page 6: Protecting personnel, property and · PDF fileRosemount™ 928 Wireless Gas Monitor with 628 series Hydrogen Sulfide Sensor ... Net Safety™ Air Particle Monitor ... FGD-BRO-Safety-Monitoring

6

Ultrasonic Gas Leak Detector

Incus Ultrasonic Gas Leak DetectorSpecifically designed to detect gas leaks at the speed of sound while providing wide area coverage. It is unaffected by inclement weather, wind, leak direction, and gas dilution or stratification. When used with Emerson’s point gas and optical flame detectors, a complete and comprehensive safety system is ensured.

� No calibration required

� Quad sensing heads provide the widest overall detection range available on the market

� Sensors are free of moving parts and will not age, drift, or need replacing

� Automated electronic self-test offers failsafe operation

� Operating Temperature: -40 °F to 185 °F (-40 °C to 85 °C)

� Area coverage: 7 to 65 ft (2 to 20 m) radius

� Programmable time delays to eliminate intermittent unwanted alarm sources

� Approvals: IECEx, ATEX, c FM us, EAC, KOSHA, INMETRO, ABS, DNV

Rosemount™ Open Path Gas Detectors

935 Open Path Combustible GasOpen path detection system providing continuous monitoring for combustible hydrocarbon gases.

� Xenon Flash infrared transmitter and receiver

� Detects hydrocarbon gases including methane, ethylene, propane, ethane and butane

� High false alarm immunity

� Withstands extreme vibration conditions

� Detection range: 7–200 m in three different models (same detector different sources)

� Operating Temperature: 23 to 660 ft (7 to 200 m)

� Approvals: ATEX, IECEx, FM/FMC, GOST R, INMETRO, CU TR, SIL 2 (TÜV), M 6325, EN60079

Page 7: Protecting personnel, property and · PDF fileRosemount™ 928 Wireless Gas Monitor with 628 series Hydrogen Sulfide Sensor ... Net Safety™ Air Particle Monitor ... FGD-BRO-Safety-Monitoring

7

Net Safety™ Air Particle Monitor

Millennium Air Particle Monitor (APM)The only Infrared optical monitor that is certified for use in hazardous areas for constant, reliable monitoring of ambient air for oil mist products of combustion such as smoke, carbon, dust, and ash.

� Perform a zero in 60 seconds from start to finish

� Multi-language, bright scrolling LED display allows operators to modify at installation site

� Not affected by high volume air velocity

� Operating Temperature: -40 °F to 167 °F (-40 °C to 75 °C)

� Approvals: CSA, ATEX, IECEx

Aspirator Systems

Gas & Smoke Aspirator SystemsUnique solution to accurately monitor gas and/or smoke ingress in areas where it is not practical to place a detector.

� Adjustable vacuum created by an air driven eductor

� Fail safe sample line clearance and detector testing

� Monitor for sample line blockages

� Suitable for high and low temperature applications

� Approvals: Zone 1 & 2 hazardous areas, explosion proof pump version available, SIL rated low flow alarm available

Page 8: Protecting personnel, property and · PDF fileRosemount™ 928 Wireless Gas Monitor with 628 series Hydrogen Sulfide Sensor ... Net Safety™ Air Particle Monitor ... FGD-BRO-Safety-Monitoring

The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their respective owners. ©2017 Emerson. All rights reserved.FGD-BRO-Safety-Monitoring

Global HeadquartersEmerson Automation Solutions 6021 Innovation Blvd.Shakopee, MN 553379USAT +1 866 347 3427F +1 952 949 [email protected]/FlameGasDetection

Analyticexpert.comFacebook.com/RosemountYouTube.com/user/RosemountAnalyticalTwitter.com/Rosemount_News

Engineered to perform in the most challenging conditions on earth!