PROTECT - Workwear Group Online · 4 6.8 CAL 8.4 CAL 70E NFPA 2112 NFPA ISO 11612 GUIDE TO OUR...

20
PROTECT

Transcript of PROTECT - Workwear Group Online · 4 6.8 CAL 8.4 CAL 70E NFPA 2112 NFPA ISO 11612 GUIDE TO OUR...

PROTECT

Hard Yakka’s reputation is built on hard work. We pride ourselves on having produced quality workwear for over 80 years, and with good reason. Our products are specifically engineered to endure the toughest of conditions while delivering comfort, safety and durability at all times.

PROTECT is our most tenacious range of workwear yet. It’s rugged, comfortable and practical – and delivers protection against flash fire and arc flash. Like all Hard Yakka products, the PROTECT range delivers

superior comfort and design innovation without compromising your safety.

The ShieldTEC flame resistant ("FR") range meets the toughest Australian and New Zealand guidelines for flame resistant garments and safety standards worldwide.

ShieldTEC FR garments are independently tested and certified to:

• NFPA 2112 Protection of Industrial Personnel Against Flash Fire

• ISO 11612 Clothing to Protect Against Heat and Flame

And tested to NFPA 70E Electrical Safety in the Workplace. The garments also meet ENA

NENS09 National Guidelines for Electrical Arc Hazards.

Importantly for Australian conditions, Hard Yakka ShieldTEC FR offers superior protection, breathability and comfort, helping to reduce the risks of heat stress.

All ShieldTEC FR garments provide UPF 50+, Excellent Protection rating while remaining durable, lightweight and moisture wicking.

Whatever your industry, ShieldTEC FR workwear buys you vital seconds that could save your life.

PROTECT

CONTENTS Guide to Our Icons 4

State of the Nation: FR Safety Report 5

ShieldTec FR Uppers 7

ShieldTec FR Lowers 11

Quick Reference Guide 14

Product Overview 15

FR Protection: Industry Information 16

Product Testing & Industry Standards 17

Important Terminology 18

Fitting Guide 19

4

6.8

CAL

8.4

CAL

70E

NFPA

2112

NFPA

ISO 11612

GUIDE TO OUR ICONS

UPF RATINGAn Ultraviolet Protection Factor (UPF) rating for Ultraviolet Radiation transmitted through a fabric onto the skin. Look for garments with a UPF 40 or 50+ rating to be assured of excellent protection.

HI-VISIBILITY DAY/NIGHTFor use in day, night, dawn, dusk or in poor weather conditions where there is illumination from headlights. Complies with AS/NZS 4602.1:2011 High-Visibility Safety Garments Class Day/Night.

MOISTURE MANAGEMENTFabric is engineered to wick moisture away from the skin and to the fabric surface so that you stay dry, cool and safe.

LIGHTWEIGHT FABRICFabric is lightweight to keep you cool and comfortable.

HI-VISIBILITY DAYA garment that uses high-visibility materials for outdoor use only. Complies with AS/NZS 4602.1:2011 High-Visibility Safety Garments Class Day.

CAL 8.4Protective value rating of ATPV 8.4 cal/cm2 which meets NFPA 70E:2015, Category 2.

NFPA 2112:2012Certified to the USA's NFPA 2112:2012 Flame-Resistant Garments for Protection of Industrial Personnel Against Flash Fire.

NFPA 70E:2015Tested to the USA's NFPA 70E:2015 Electrical Safety in the Workplace Standard.

ANTI-STATICDesigned to reduce the build up of excess static electricity. This offers a level of protection against ignition hazards such as flammable materials and gases.

ISO 11612:2015Certified to Europe's ISO 11612:2015 Protective Clothing – Clothing to Protect Against Heat and Flame Standard.

CAL 6.8Protective value rating of ATPV 6.8 cal/cm2 which meets NFPA 70E:2015, Category 1.

5

There are over 2.85 million people working in industries exposed to arc flash and flash fire across Australia. Through the Hard Yakka flame resistant (FR) clothing safety report, we aimed to uncover the level to which employees protect themselves at work and sought to understand the number of injuries that take place onsite as a result of insufficient protection. The report is alarming, and key insights can be found below.

Based on research of 500 people working in fields at risk of arc flash and flash fire. Research conducted by Symphony Research on behalf of Hard Yakka PROTECT in June 2015.

MOST AT RISK

Electrical & Energy workers are at the biggest risk to arc flash (74%).

Emergency Services workers are at the biggest risk to flash fire (59%).

INJURIES

RECOVERY

INJURED AREA

56%56% of workers have experienced a near miss injury due to arc flash or flash fire.

21% 16% 23%Third degree burns (21%) Second degree burns (16%) First degree burns (23%)

47% 10% 83%47% of those injured took

longer than a week o� work10% spent more than

$15,000 on medical care83% of participants had

immediate access to first aid when injured

$

3% Eyes 20% Face

17% Shoulders

14% Back

35% Hands

9% Feet

16% Neck

34% Arms

13% Chest

23% Legs

37%

MISTAKEN WORKPLACE FR FIBRES

28%28% DO NOT wear FR clothing, with the main reason being that their company doesn’t supply it to them (36%), and they don’t feel they need to (31%).

There is some confusion over what constitutes an FR fibre: Only 37% were able to correctly identify FR fibres. Cotton (25%) was the most commonly mistaken fibre for FR.

67% of those who wear FR clothing could not correctly name FR fibres.

67%

74%

59%

STATE OF THE NATION: FR SAFETY REPORT

SHIELDTEC FR

7

SHIELD

TEC FR

SHIELDTEC FR UPPERSLightweight fire resistant range of shirts to reduce risk from Arc and Flash fire events.

• Lightweight 195gsm (Protex®) Modacrylic, Pima Cotton, (Kevlar®) Para-Aramid, Nylon and (Beltron®) Anti-static fibre

• Anti-static fibre, intimately blended

• Rip-stop fabric increases durability

• Two chest pockets with reinforcement

• Pleated yoke, side body and gusset plus articulated sleeves for movement

• Gusset cuff for protection

• Heat resistant trims tested to 260°C

• FR reflective tape – hoop configuration*

• Size range: S – 5XL

Articulated sleeves for movement

NFPA 2112 certified trims test to 260°C

Pleated yoke for movement

Side body and gusset for comfort and movement

Gusset cuff for protection

Twin needled for strength. All thread NFPA 2112 certified.

Open and closed front options with concealed placket

* Y04050, Y04150, Y04350, Y04550ATPV: 6.8 CAL/CM2

8

Y04350 HI-VIS SPLICED OPEN FRONT LONG SLEEVE SHIRT WITH FR TAPE

Yellow/Navy (YNA) Orange/Navy (ONA)Navy (NAV)

Y04150 FULL HI-VIS CLOSED FRONT LONG SLEEVE SHIRT WITH FR TAPE

Safety Orange (SOR)

Y04250 LONG SLEEVE CLOSED FRONT SHIRT

6.8

CAL

6.8

CAL

6.8

CAL

70E

NFPA

70E

NFPA

70E

NFPA

2112

NFPA

2112

NFPA

2112

NFPA

ISO 11612 ISO 11612 ISO 11612

SHIELDTEC FR

9

Y04550 HI-VIS SPLICED CLOSED FRONT LONG SLEEVE SHIRT WITH FR TAPE

Yellow/Navy (YNA) Orange/Navy (ONA)

Y04450 HI-VIS SPLICED OPEN FRONT LONG SLEEVE SHIRT

Yellow/Navy (YNA) Orange/Navy (ONA)

Y04050 WOMEN'S HI-VIS SPLICED OPEN FRONT LONG SLEEVE SHIRT WITH FR TAPE

Yellow/Navy (YNA) Orange/Navy (ONA)

6.8

CAL

6.8

CAL

6.8

CAL

70E

NFPA

70E

NFPA

70E

NFPA

2112

NFPA

2112

NFPA

2112

NFPA

ISO 11612 ISO 11612 ISO 11612

SHIELD

TEC FR

SHIELDTEC FR

11

SHIELD

TEC FR

SHIELDTEC FR LOWERSFire resistant range of pants to reduce risk from Arc and Flash fire events.

• 235gsm (Protex®) Modacrylic, Pima Cotton, (Kevlar®) Para-Aramid, Nylon and (Beltron®) Anti-static fibre

• Anti-static fibre, intimately blended

• Inleg gusset for comfort and movement

• Articulated knees

• Secure pockets for storage on cargo styles

• FR reflective tape - hoop configuration*

• Size range: Men's 77R – 107R, 87S – 112S Women's 8 – 22

* Y02320, Y02425, Y02525 ATPV: 8.4 CAL/CM2

Articulated knees for movement

NFPA 2112 certified trims test to 260°C

Inleg gusset for comfort and movement

Twin needled and bar tacked for strength. All thread NFPA 2112 certified.

Plain front pant, cargo pant, women's options with and without tape

12

Y02525 FLAT FRONT CARGO POCKET PANT WITH FR TAPE

Navy (NAV)

Y02520 FLAT FRONT CARGO POCKET PANT

Navy (NAV)

Y02425 FLAT FRONT PANT (NO POCKETS) WITH FR TAPE

Navy (NAV)

8.4

CAL

8.4

CAL

8.4

CAL

70E

NFPA

70E

NFPA

70E

NFPA

2112

NFPA

2112

NFPA

2112

NFPA

ISO 11612 ISO 11612 ISO 11612

SHIELDTEC FR

13

Y02320 WOMEN'S CARGO PANT WITH TAPE

Navy (NAV) Navy (NAV)

Y02325 WOMEN'S FLAT FRONT PANT WITH TAPE (NO POCKETS)

Navy (NAV)

Y02420 FLAT FRONT PANT (NO POCKETS)

8.4

CAL

8.4

CAL

8.4

CAL

70E

NFPA

70E

NFPA

70E

NFPA

2112

NFPA

2112

NFPA

2112

NFPA

ISO 11612 ISO 11612 ISO 11612

SHIELD

TEC FR

Range Comparison SHIELDTEC FR

Bulwark iQ Series TECGEN™ Tecasafe Plus Tecasafe Plus

(Y00308 only)

Fabric exclusive to Hard Yakka PROTECT in Australasia

Heat stress management rating (3=best, 2=better, 1=good) 2-3 3 2-3 2 2-3

Weight & CAL rating – upper body garments (includes shirts, polos, coveralls)

195gsm, 6.8 cal/cm2

180gsm, 8.2 cal/cm2

217gsm, 8.6 cal/cm2

238gsm, 8.9 cal/cm2

197gsm, 5.7 cal/cm2

Weight & CAL – lower body garments (includes pants)

235gsm, 8.4 cal/cm2

425gsm, 13 cal/cm2

214gsm, 8.6 cal/cm2

238gsm, 8.9 cal/cm2 NA

Garments AND fabric certified to NFPA 2112

Garments AND fabric certified to ISO 11612

NFPA 2112 certified trims tested to 260°C

Fabric tested to NFPA 70E & NFPA 2112

Fabric meets ENA NENS 09 Guidelines for Electric Arc Hazards

AS/NZS 4399:1996 UPF Rating50+ Excellent

Protection30+ Very Good

Protection50+ Excellent

Protection50+ Excellent

Protection50+ Excellent

Protection

Meets NS/NZS 4602.1:2011 for high-visibility safety garments

Tape Options FR Tape Segmented FR Tape

Perforated FR Tape FR Tape FR Tape

Use of FR trims such as fasteners, thread and reflective tape

FR properties do not wash out

PROTECT QUICK REFERENCE GUIDE

14

Style Description NFPA 2112

NFPA 70E ISO 11612

NENS COMPLI-

ANTAS 4602

DAYAS 4602

DAY/NIGHT

ATPV 6.8 CAL/

CM2

ATPV 8.4 CAL/

CM2

195 GSM FABRIC

235 GSM FABRIC FR TAPE

TRIMS TESTED

TO 260°C

UPF 50+ CLOSED FRONT

OPEN FRONT

GUSSET CUFF

ARTICU- LATED

FIT

Y04150 Full Hi-Vis Closed Front Long Sleeve Shirt with FR tape

Y04250 Long Sleeve Closed Front Shirt

Y04350 Hi-Vis Spliced Open Front Long Sleeve Shirt with FR tape

Y04450 Hi-Vis Spliced Open Front Long Sleeve Shirt

Y04550 Hi-Vis Spliced Closed Front Long Sleeve Shirt with FR tape

Y02420 Flat front pant (no pockets)

Y02425 Flat front pant (no pockets) with FR tape

Y02520 Flat front cargo pocket pant

Y02525 Flat front cargo pocket pant with FR tape

Y04050 Women's Hi-Vis Spliced Open Front Long Sleeve Shirt with FR tape

Y02320 Women's Cargo Pant with FR tape

Y02325 Women's Flat front pant with FR tape (no pockets)

15

SHIELDTEC FR PRODUCT OVERVIEW

16

Every day workers expose themselves to potentially hazardous environments that cause flash fires and arc flash, leading to common injuries such as burns, respiratory system damage, hearing damage and even fatalities.

The demand for flame resistant clothing is growing rapidly as industries build an understanding of the hazardous nature of their working environments and their apparel protection requirements. The use of flame resistant clothing provides the necessary protection to reduce the risk of serious, or even fatal injuries.

Hard Yakka PROTECT workwear is specifically designed to cater for the increasing demands of multiple industries including electrical, energy, oil, gas and mining.

Electrical & EnergyIn the electrical and energy industries the most common risk is an arc flash event. Arc flash events typically occur around energised equipment such as power boards, power lines and general powered equipment. Arc flash events can cause serious and even fatal injuries.

Flame resistant workwear in these industries is intended to self-extinguish flame that has ignited on the garment and provide protection against second-degree burns. Heat stress management is also important for safety.

Oil & GasOil and gas industry workers can be exposed to flash fires, arc flash events (if operating energised equipment) and extreme heat conditions. Wearing flame resistant clothing that self-extinguishes can give workers much needed time to escape a flash fire and dramatically reduce burn injuries.

Heat stress management is also critical, with most upstream oil and gas activities concentrated in hot climates. Flame resistant clothing aims to provide both FR protection and breathability through fabric technology and garment design.

MiningMiners can be exposed to both flash fires and arc flash events. Typical mine site workers at risk include boilermakers, drillers and electricians. Flame resistant workwear can protect workers against second and third degree burns and manage heat stress in hot/humid conditions.

FR PROTECTION: INDUSTRY INFORMATION

17

Flame resistant garments are driven by standards and specifications that must pass intensive testing before they can be offered in any marketplace.

A basic understanding of how flame resistance is defined and measured is very important. The following is a list of the industry standards to which ShieldTEC FR garments are compliant and certified.

NFPA 70E – National Fire Protection Association, National Electrical CodeThe USA's NFPA 70E guidelines require employees working on or near energised parts and equipment to wear situationally appropriate FR clothing that meets the requirements of test method ASTM F1506. ASTM F1506 provides the minimum performance specifications for protective clothing and outlines the required testing methods to measure the Arc Thermal Protection Value (ATPV).

ENA NENS 09 – National Guidelines for the Selection, Use & Maintenance of Personal Protective Equipment for Electrical Hazards Energy Networks Association is an Australian body who administers NENS 09 guidelines which set the minimum standards for the selection, use and maintenance of personal protective equipment (PPE) when used to protect employees against electrical hazards within the electricity supply industry.

NFPA 2112 – National Fire Protection Association Standard on Flame Resistant Garments for Protection of Industrial Personnel Against Flash FireOriginating in the USA, NFPA 2112 is an industry guide to flame resistant garments for protection of industrial personnel against flash fire. The standard provides minimum performance criteria and outlines 17 test methods including: flame resistance, char-length, thermal shrinkage resistance and heat resistance.

ISO 11612:2015 Protective Clothing – Clothing to Protect Against Heat and FlameISO is an independent European based organization that develops international standards for participating member countries. ISO standard 11612:2015 provides the wearer with protection against transitory contact with heat and flame. The heat can be convection heat, thermal radiation, metal splash or a combination of these.

Garments are given the following classifications based on specific parameters:

(A1) Limited flame spread, surface ignition method(A2) Limited flame spread, edge ignition method(B) Convection heat(C) Thermal radiation(D) Molten aluminum splash (E) Molten iron splash(F) Contact heat

AS/NZS 4602.1:2011 Australian and New Zealand High-Visibility StandardsStandards for high-visibility clothing dictate workwear colour and design to ensure workers are seen in high risk situations. All Hard Yakka PROTECT Hi-Visibility Workwear complies with AS/NZS 4602.1:2011 for high-visibility safety garments.

AS/NZS 4399:1996 Sun Protective ClothingAll ShieldTEC FR garments are rated UPF 50+ Excellent Protection.

WARNING: ShieldTEC garments are not intended for fire entry, structural or wildlands fire fighting activities and provide no personal protection from chemical exposure.

They should be removed at once if contaminated with flammable liquid or material.

Both upper and lower body must be covered by a combination of FR shirt and FR pants, worn with the shirt tucked into the pants. All fasteners must be closed at all times during use. Sleeves and pants are not to be worn rolled up.

PRODUCT TESTING & INDUSTRY STANDARDS

1818

Arc FlashA type of electrical explosion. An arc flash is not an electric shock – it occurs when uncontrolled amounts of electric current travel through air between two conductors.

Arc Thermal Performance Value (ATPV) This value is presented in calories per square centimetre (cal/cm2) and represents the maximum capability for arc flash protection of a particular garment. The incident energy on a fabric or material that results in a 50% probability that sufficient heat transfer through the tested specimen is predicted to cause the onset of a second degree skin burn injury.

Cotton Drill WorkwearClothing designed to do everyday work. There is a misconception that untreated 100% cotton fabric is somehow “flame resistant”. This is simply not true. While heavyweight, untreated 100% cotton fabrics may be more difficult to ignite they can, and will, ignite and continue to burn if exposed to an ignition source.

Fire Retardant WorkwearStructural garments targeted to firefighting industries that are intended to prevent ignition.

Flame Resistant WorkwearFlame resistant fabrics and garments are intended to resist ignition, prevent the spread of flames and to self-extinguish almost immediately upon removal of the ignition source. Flame resistant workwear is abbreviated in this catalogue as 'FR'.

Flash FireA rapidly moving flame front which can be a combustion explosion.

Inherent FR FabricInherently flame resistant fibres are defined as having flame resistance as an essential characteristic of the fibre. It is a fabric that does not support combustion and has innate flame resistant properties that are permanent and inseparable; the flame resistant qualities will never wash out.

Treated FR FabricFibres that are not normally considered flame resistant which have been chemically treated to provide FR protection.

IMPORTANT TERMINOLOGY

19

FITTING GUIDEMEN'S REGULAR PANT

SIZE TABLE

BODY MEASUREMENT

GARMENT MEASUREMENT

AWAIST

(CM)

BHEIGHT

(CM)WAIST

(CM)INSEAM

(CM)

77R 77 178-188 78 83

82R 82 178-188 83 83

87R 87 178-188 88 83

92R 92 178-188 93 83

97R 97 178-188 98 83

102R 102 178-188 103 83

107R 107 178-188 108 83

MEN'S STOUT PANT

SIZE TABLE

BODY MEASUREMENT

GARMENT MEASUREMENT

AWAIST

(CM)

BHEIGHT

(CM)WAIST

(CM)INSEAM

(CM)

87S 87 163-173 88 78

92S 92 163-173 93 78

97S 97 163-173 98 78

102S 102 163-173 103 78

107S 107 163-173 108 78

112S 112 163-173 113 78

117S 117 163-173 118 78

122S 122 163-173 123 78

127S 127 163-173 128 78

132S 132 163-173 133 78

MEN'S SHIRT

SIZE TABLE

BODY MEASUREMENT

GARMENT MEASUREMENT

AWAIST

(CM)

BHEIGHT

(CM)WAIST (CM)

S 92 178-188 113

M 97 178-188 118

L 102 178-188 123

XL 110 178-188 131

2XL 118 178-188 139

3XL 126 178-188 147

4XL 134 178-188 155

5XL 142 178-188 163

DATE CREATED: 9/10/2015

DIMENSIONS: 100x158 mm PMS Process Black

MARK UP (do not print)White

WARNINGTHIS GARMENT IS NOT INTENDED FOR FIRE ENTRY, STRUCTURAL

OR WILDLANDS FIRE FIGHTING ACTIVITIES AND PROVIDES NO PERSONAL PROTECTION FROM CHEMICAL EXPOSURE.

REMOVE AT ONCE IF CONTAMINATED WITH FLAMMABLE LIQUID OR MATERIAL.

BOTH UPPER AND LOWER BODY MUST BE COVERED BY A COMBINATION OF FIRE RESISTANT (FR) SHIRT AND FR PANTS,

WORN WITH THE SHIRT TUCKED INTO THE PANTS. REACH ARMS UPWARD TO ENSURE NO PART OF THE TORSO IS EXPOSED

DURING ANY MOVEMENT. ALL FASTENERS MUST BE CLOSED AT ALL TIMES DURING USE. SLEEVES AND PANTS ARE

NOT TO BE WORN ROLLED-UP.USE FLAME RESISTANT THREAD FOR EMBROIDERY. ANY ALTERATIONS MAY IMPACT THE COMPLIANCE,

PERFORMANCE AND FUNCTIONALITY OF THE GARMENT.

THIS GARMENT IS FLAME RESISTANTTHIS GARMENT MEETS THE PERFORMANCE REQUIREMENTS OF

NFPA 70E-2015: ASTM 1506-10A AND IS CERTIFIED TO ISO 11612:2015.

ML-1126-HY - SHIELDTEC FR WOVEN MENS REGULAR PANT

DO NOT REMOVE THIS LABEL

B

A

SIZETABLE

77R

82R

87R

92R

97R

102R

107R

AWAIST(CM)

77

82

87

92

97

102

107

ML-

1126

-HY

BHEIGHT

(CM)178-188

178-188

178-188

178-188

178-188

178-188

178-188

WAIST(CM)

78

83

88

93

98

103

108

INSEAM(CM)

83

83

83

83

83

83

83

GARMENTMEASUREMENT

BODY MEASUREMENT

ISO 11612:2015

A1 A2 B1 C1 F1

READ USER

INSTRUCTIONSBMP 642936

DATE CREATED: 9/10/2015

DIMENSIONS: 100x154 mm PMS Process Black

MARK UP (do not print)White

WARNINGTHIS GARMENT IS NOT INTENDED FOR FIRE ENTRY, STRUCTURAL

OR WILDLANDS FIRE FIGHTING ACTIVITIES AND PROVIDES NO PERSONAL PROTECTION FROM CHEMICAL EXPOSURE.

REMOVE AT ONCE IF CONTAMINATED WITH FLAMMABLE LIQUID OR MATERIAL.

BOTH UPPER AND LOWER BODY MUST BE COVERED BY A COMBINATION OF FIRE RESISTANT (FR) SHIRT AND FR PANTS,

WORN WITH THE SHIRT TUCKED INTO THE PANTS. REACH ARMS UPWARD TO ENSURE NO PART OF THE TORSO IS EXPOSED

DURING ANY MOVEMENT. ALL FASTENERS MUST BE CLOSED AT ALL TIMES DURING USE. SLEEVES AND PANTS ARE

NOT TO BE WORN ROLLED-UP.USE FLAME RESISTANT THREAD FOR EMBROIDERY. ANY ALTERATIONS MAY IMPACT THE COMPLIANCE,

PERFORMANCE AND FUNCTIONALITY OF THE GARMENT.

THIS GARMENT IS FLAME RESISTANTTHIS GARMENT MEETS THE PERFORMANCE REQUIREMENTS OF

NFPA 70E-2015: ASTM 1506-10A AND IS CERTIFIED TO ISO 11612:2015.

ML-1127-HY - SHIELDTEC FR WOVEN MENS STOUT PANT

B

A

DO NOT REMOVE THIS LABEL

SIZE TABLE

87S

92S

97S

102S

107S

112S

AWAIST(CM)

87

92

97

102

107

112

ML-

1127

-HY

BHEIGHT

(CM)163-173

163-173

163-173

163-173

163-173

163-173

WAIST(CM)

88

93

98

103

108

113

INSEAM(CM)

78

78

78

78

78

78

BODY MEASUREMENT GARMENTMEASUREMENT

ISO 11612:2015

A1 A2 B1 C1 F1

READ USER

INSTRUCTIONSBMP 642936

DATE CREATED: 9/10//2015

DIMENSIONS: 100x157 mm PMS Process Black

MARK UP (do not print)White

WARNINGTHIS GARMENT IS NOT INTENDED FOR FIRE ENTRY, STRUCTURAL

OR WILDLANDS FIRE FIGHTING ACTIVITIES AND PROVIDES NO PERSONAL PROTECTION FROM CHEMICAL EXPOSURE.

REMOVE AT ONCE IF CONTAMINATED WITH FLAMMABLE LIQUID OR MATERIAL.

BOTH UPPER AND LOWER BODY MUST BE COVERED BY A COMBINATION OF FIRE RESISTANT (FR) SHIRT AND FR PANTS,

WORN WITH THE SHIRT TUCKED INTO THE PANTS. REACH ARMS UPWARD TO ENSURE NO PART OF THE TORSO IS EXPOSED

DURING ANY MOVEMENT. ALL FASTENERS MUST BE CLOSED AT ALL TIMES DURING USE. SLEEVES AND PANTS ARE

NOT TO BE WORN ROLLED-UP.USE FLAME RESISTANT THREAD FOR EMBROIDERY. ANY ALTERATIONS MAY IMPACT THE COMPLIANCE,

PERFORMANCE AND FUNCTIONALITY OF THE GARMENT.

THIS GARMENT IS FLAME RESISTANTTHIS GARMENT MEETS THE PERFORMANCE REQUIREMENTS OF

NFPA 70E-2015: ASTM 1506-10A AND IS CERTIFIED TO ISO 11612:2015.

ML-1129-HY - SHIELDTEC FR WOVEN MENS SHIRT

DO NOT REMOVE THIS LABEL

A

B

SIZE TABLE

SML

XL2XL3XL4XL5XL

ACHEST(CM)

9297102110118126134142

ML-

1129

-HY

BHEIGHT

(CM)178-188178-188178-188178-188178-188178-188178-188178-188

CHEST(CM)113118123131139147155163

BODY MEASUREMENT GARMENTMEASUREMENT

ISO 11612:2015

A1 A2 B1 C1

READ USER

INSTRUCTIONSBMP 642936

WOMEN'S SHIRT

SIZE TABLE

BODY MEASUREMENT

GARMENT MEASUREMENT

A CHEST

(CM)

BWAIST

(CM)

CHEIGHT

(CM)CHEST (CM)

6 80 62 168-173 93

8 85 67 168-173 98

10 90 72 168-173 103

12 95 77 168-173 108

14 100 82 168-173 113

16 105 87 168-173 118

18 110 92 168-173 125

20 115 97 168-173 133

22 120 102 168-173 139

24 125 107 168-173 145

WOMEN'S PANT

SIZE TABLE

BODY MEASUREMENT

GARMENT MEASUREMENT

A WAIST

(CM)

BHIP

(CM)

CHEIGHT

(CM)HIP

(CM)INSEAM

(CM)

6 62 88 168-173 94 81

8 67 93 168-173 100 81

10 72 98 168-173 105 81

12 77 103 168-173 110 81

14 82 108 168-173 115 81

16 87 113 168-173 120 81

18 92 118 168-173 128 81

20 97 123 168-173 135 81

22 102 128 168-173 140 81

24 107 133 168-173 145 81

DATE CREATED: 9/10/2015

DIMENSIONS: 100x159 mm PMS Process Black

MARK UP (do not print)White

WARNINGTHIS GARMENT IS NOT INTENDED FOR FIRE ENTRY, STRUCTURAL

OR WILDLANDS FIRE FIGHTING ACTIVITIES AND PROVIDES NO PERSONAL PROTECTION FROM CHEMICAL EXPOSURE.

REMOVE AT ONCE IF CONTAMINATED WITH FLAMMABLE LIQUID OR MATERIAL.

BOTH UPPER AND LOWER BODY MUST BE COVERED BY A COMBINATION OF FIRE RESISTANT (FR) SHIRT AND FR PANTS,

WORN WITH THE SHIRT TUCKED INTO THE PANTS. REACH ARMS UPWARD TO ENSURE NO PART OF THE TORSO IS EXPOSED

DURING ANY MOVEMENT. ALL FASTENERS MUST BE CLOSED AT ALL TIMES DURING USE. SLEEVES AND PANTS ARE

NOT TO BE WORN ROLLED-UP.USE FLAME RESISTANT THREAD FOR EMBROIDERY. ANY ALTERATIONS MAY IMPACT THE COMPLIANCE,

PERFORMANCE AND FUNCTIONALITY OF THE GARMENT.

THIS GARMENT IS FLAME RESISTANTTHIS GARMENT MEETS THE PERFORMANCE REQUIREMENTS OF

NFPA 70E-2015: ASTM 1506-10A AND IS CERTIFIED TO ISO 11612:2015.

ML-1128-HY - SHIELDTEC FR WOVEN WOMENS PANT

B

C

A

DO NOT REMOVE THIS LABEL

SIZE TABLE

681012141618202224

AWAIST(CM)

6267727782879297102107

BHIP

(CM)889398103108113118123128133

ML-

1128

-HY

CHEIGHT

(CM)168-173168-173168-173168-173168-173168-173168-173168-173168-173168-173

HIP(CM)94100105110115120128135140145

INSEAM(CM)

81818181818181818181

BODY MEASUREMENT GARMENTMEASUREMENT

ISO 11612:2015

A1 A2 B1 C1 F1

READ USER

INSTRUCTIONSBMP 642936

DATE CREATED: 9/10/2015

DIMENSIONS: 100x159 mm PMS Process Black

MARK UP (do not print)White

WARNINGTHIS GARMENT IS NOT INTENDED FOR FIRE ENTRY, STRUCTURAL

OR WILDLANDS FIRE FIGHTING ACTIVITIES AND PROVIDES NO PERSONAL PROTECTION FROM CHEMICAL EXPOSURE.

REMOVE AT ONCE IF CONTAMINATED WITH FLAMMABLE LIQUID OR MATERIAL.

BOTH UPPER AND LOWER BODY MUST BE COVERED BY A COMBINATION OF FIRE RESISTANT (FR) SHIRT AND FR PANTS,

WORN WITH THE SHIRT TUCKED INTO THE PANTS. REACH ARMS UPWARD TO ENSURE NO PART OF THE TORSO IS EXPOSED

DURING ANY MOVEMENT. ALL FASTENERS MUST BE CLOSED AT ALL TIMES DURING USE. SLEEVES AND PANTS ARE

NOT TO BE WORN ROLLED-UP.USE FLAME RESISTANT THREAD FOR EMBROIDERY. ANY ALTERATIONS MAY IMPACT THE COMPLIANCE,

PERFORMANCE AND FUNCTIONALITY OF THE GARMENT.

THIS GARMENT IS FLAME RESISTANTTHIS GARMENT MEETS THE PERFORMANCE REQUIREMENTS OF

NFPA 70E-2015: ASTM 1506-10A AND IS CERTIFIED TO ISO 11612:2015.

ML-1130-HY - SHIELDTEC FR WOVEN WOMENS SHIRT

A

C

B

DO NOT REMOVE THIS LABEL

SIZE TABLE

681012141618202224

ACHEST(CM)80859095100105110115120125

BWAIST(CM)

6267727782879297102107

ML-

1130

-HY

CHEIGHT

(CM)168-173168-173168-173168-173168-173168-173168-173168-173168-173168-173

CHEST(CM)

9398103108113118125133139145

BODY MEASUREMENT GARMENTMEASUREMENT

ISO 11612:2015

A1 A2 B1 C1

READ USER

INSTRUCTIONSBMP 642936

hardyakka.com.au/protect-range

WORKWEAR GROUP

Level 1, 187 Todd Rd Port Melbourne VIC 3207 Australia

TELEPHONE

Customer Service 1800 644 517

ABN 82 004 055 387

©2016 Hard Yakka