PROPOSED PACKAGE CAPACITY: 2.0 MW (2500KVA) AGN Technology offers the full and complete 2.0 MW of electricity package as a turnkey solution. The enter package shall be install and test for client by AGN Technology engineering department. Package Price for 2.8MW Synchronized Electricity: $1.545m** Package Price for Grid Connected 2.0 MW Synchronized Electricity: Call For Details Price **Note: Synchronized 5 generator (Diesel Engine) and through power to one common bas-bar. Payment Terms: 60% advance along with at the time of contract singing, Balance 30% payment after delivery materials to site and remaining 10% will be payment at the time of project handover to the client. Payment Terms for War Zone Countries: 80% advance along with at the time of contract singing, Balance 20% will be payment after delivery materials to the site. Civil Construction and Site Preparation: Project related all civil construction and site preparation is the fully client responsibility. Material Transportation: Inside UAE: Transport all material from AGN Technology warehouse (in UAE) to site location is including with package price. Outside UAE: Transport all material from AGN Technology warehouse (in UAE) to site location is the client responsibility. Security and AGN Technical Staff Accommodations: Inside UAE: A security and AGN technical staff accommodations in UAE is the AGN Technology responsibility. Outside UAE and War Zone Countries: Security, Accommodation and Transportations of all AGN technical staff are the sole responsibility of the client in the war zone countries. It can be discussed in full details once the contract is signed between AGN & its clients. Price Change: All Price are subject to change and alternation without prior notice. Should the prices changes during the contract, AGN will not change price for existing client contract. Contract Cancelation Terms: Once the contract is signed and fully discussed in details, the payment /deposit is for failed and non- refundable at any circumstance. Delay of payment shall be the same as the cancelation of the project the time both party agree up on.

Transcript of PROPOSED PACKAGE CAPACITY: 2.0 MW (2500KVA) · Spin on fuel filters with water separator Standard...

PROPOSED PACKAGE CAPACITY: 2.0 MW (2500KVA) AGN Technology offers the full and complete 2.0 MW of electricity package as a turnkey solution. The enter package shall be install and test for client by AGN Technology engineering department.

Package Price for 2.8MW Synchronized Electricity: $1.545m**

Package Price for Grid Connected 2.0 MW Synchronized Electricity: Call For Details Price **Note: Synchronized 5 generator (Diesel Engine) and through power to one common bas-bar.

Payment Terms: 60% advance along with at the time of contract singing, Balance 30% payment after delivery materials to site and remaining 10% will be payment at the time of project handover to the client.

Payment Terms for War Zone Countries: 80% advance along with at the time of contract singing, Balance 20% will be payment after delivery materials to the site. Civil Construction and Site Preparation: Project related all civil construction and site preparation is the fully client responsibility. Material Transportation: Inside UAE: Transport all material from AGN Technology warehouse (in UAE) to site location is including with package price. Outside UAE: Transport all material from AGN Technology warehouse (in UAE) to site location is the client responsibility. Security and AGN Technical Staff Accommodations: Inside UAE: A security and AGN technical staff accommodations in UAE is the AGN Technology responsibility. Outside UAE and War Zone Countries: Security, Accommodation and Transportations of all AGN technical staff are the sole responsibility of the client in the war zone countries. It can be discussed in full details once the contract is signed between AGN & its clients. Price Change: All Price are subject to change and alternation without prior notice. Should the prices changes during the contract, AGN will not change price for existing client contract.

Contract Cancelation Terms: Once the contract is signed and fully discussed in details, the payment /deposit is for failed and non-refundable at any circumstance. Delay of payment shall be the same as the cancelation of the project the time both party agree up on.

LIST OF MATERIALS FOR PROPOSED PACKAGE

S/N Description of materials Quantity Required Remarks 1 Cummins Diesel Engine Generators

Capacity: 500KVA, 400 Volt & 50Hz 5x500=2500KVA

2 Synchronization Control Panel Model: ATSP09

5 No’s with common Bus-bar

3 MCCB Capacity: 1000Amps, 3 pole Brand: ABB/Schneider

5 No’s

4 Air Circuit Breaker (ACB) Capacity:4000 Amps, 3 pole Brand: ABB/ Schneider

1 No

5 Low Voltage Power Cable Voltage: 400 V Cable size: 630mm² or 400mm² Single core, Copper conductor Insulation: XLPE

As per required

6 Grounding Cable Size: 95mm², Y/G copper Conductor

As per required

7 Grounding Cable Size: 35mm², Y/G copper Conductor

As per required

8 Grounding Cable Size: 16mm², Y/G copper Conductor

As per required

9 Control Cable As per required

10

External Fuel Tank Capacity: 10K gallons

1 No

11 Fuel Pipes As per required

12 Fuel Filter 5 No

13 Accessories

Options For The Above Package

14 Step-up Power Transformer (0.4KV/33KV or 0.4KV/11KV or as per client requirements) Capacity: 2500 KVA, 50Hz

1 No As per client demand

15 SF6 RMU or SF6 Breaker or VCB Capacity: 630 Amps with all protection system

1 No As per client demand

16 High Voltage or Medium Voltage Power Cable Cable size: 300mm², Three core, Copper conductor Insulation: XLPE, Armored steel ware insulated

As per required As per client demand

17 20’ Container 5 No As per client demand

Civil constrictions are the client responsibility; AGN should be to quote, If requested by client.

SINGLE LINE DIAGRAM FOR 2 MW SYNCHRONIZED ELECTRICITY

TO LOAD TO LOAD

250A/5A/1ACT s

S1

S2

Step-up Power Transformer 0.4KV/20KV or 0.4KV/11KV or 0.4KV/33KV(2500KVA) YNd11

4000A/5ACT

P1

P2

GE

N-

2

GE

N-

3

GE

N-

4

GE

N-

5

Computerized Synchronization

control panel

Sf6 RMUCapacity: 630ACT Ratio: 100:1

With Over current &Earth fault protection

Cummins Diesel GeneratorCapacity: 500kVA, 400V, 50Hz

MCCB 1000A,4P,50KAWITH SCC, OC PROTECTIONWITH MOTOR OPERATOR

1000/1A1000/5A

CTCTCT

1000/5A

Computerized Synchronization Control Panel

Air Circuit Breaker (ACB)Capacity: 4000A

CT Ratio: 4000/1A/5A

With all metering & protection

Vacuum Circuit Breaker (VCB)Capacity: 630ACT Ratio: 100:1

With Over current &Earth fault protection

GE

N-

1

CT

Copyright © 1998-2009 agnenegy.comPlease note: All logos, trade marks and any other wording or pictures are used for illustration and display purposes only.

MATERIAL DESCRIPTIONS AND DETAIL TECHNICAL SPECIFICATIONS

Generator Technical Specification

1500 rpm (50 Hz Ratings): Gross Engine Output Net Engine Output Typical Generator Set Output Stand by Prime Base Stand by Prime Base Stand by (ESP) Prime (PRP) Base (COP)

KWm/BHP KWm/BHP KWe KVA KWe KVA KWe KVA

500/670 444/595 317/425 477/639 426/571 299/400 440 550 400 500 281 351

Weight & Dimensions: Length Width Height Weight(dry) mm mm mm Kg

2269 1332 1669 1658

Fuel Consumption 1500 (50 Hz):

Engine Specification

Alternator Specification

Technical information and values are according to ISO8528, ISO3046, NEMA MG1.22, IEC 600341, BS 49995000, VDE 0530 standards. All products manufactured according to ISO9001, ISO14001, OHSAS18001, TSE, CE

standards. All information given in this specification set is intended for general purposes only. Due to a policy continuous improvement AGN Technology reserves the right to amend details and specifications without notice and all information given is subject to the AGN Technology current condition of sales.

TBA: To Be Ask TBD: To Be Determined NA: Not Available N/A: Not Applicable

% KWm BPH L/ph US gal/ph

Standby Power 100 500 670 123.0 32.4

100 444 595 103.0 27.3

Prime Power 75 333 447 78.7 20.8

50 222 298 54.7 14.5

25 111 149 30.0 8

Continues Power 100 317 425 75.7 20 Standby Power Standby power is defined as the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 500 hours of operation per year under average of 70% load. Overloading is not permissible.

Prime Power Prime power is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hours.

Design 4 cycle, in-line, Turbo Charged, Air-cooled

Bore 137 mm (5.39 in.)

Stroke 169 mm (6.65 in.)

Displacement 15 liter (912.3)

Cylinder Block Cast iron, 6 cylinders Battery Capacity 100A/hr Battery Charging Alternator35 amps Starting Voltage 24 volt, negative ground Fuel System Direct injection

Fuel Filter Spin on full flow filter

Air Cleaner Type Dry replaceable element with restriction indicator

Lube Oil Filter Type(s)

Spin on fuel filters with water separator

Standard Cooling System

122 F (50 C) ambient radiator

Design Brushless single bearing

Revolving field

Stator 2/3 pitch

Rotor Single bearing Flexible disc

Insulation System Class H

Standard Temperature Rise

125 - 163 C Stand by

Exciter Type Self Excited

Phase Rotation A (U), B (V), C (W)

Alternator Cooling Direct drive centrifugal blower fan

AC Waveform Total Harmonic Distortion

No load: 1.5% None distorting balanced linear load: 5%

SYNCHRONIZATION CONTROL PANEL SPECIFICATION ATSP09 SYNCHRONIZATION CONTROL PANEL SPECIFICATIONS LOAD PROPERTIES:

Automatic and manual synchronization Can synchronized until 10 generators among

them selves and feed the workload Load sharing at generators according to power

Automatically start and stop according to load

Automatically balancing work hours (co-aging)

COMMUNICATION PROPERTIES:

Communication over (AQ) bus-bar with electronic engine control units (optional)

Alarm message with SMS (optional)

Open communication over RS 232 or RS 485 interface

Support Motbus RTU protocol (concordant with scada system)

INDICATOR PROPERTIES: LCD text indicator

All engine and alternator parameters can be watched

Engine and alternator protection

Keep the records of generator alarms, last 25 records

Expansion modules (in and out)

With LCD screen in ATSP09 synchronization panels you can measure the following rates and with the stated protection, system reliability put in first place.

MEASUREMENTS: DIRECT MEASURES:

Oil pressure

Coolant temperature

Fuel level (optional)

Oil temperature (optional)

Accumulator voltage

Engine circulation

Generator frequency

Generator phase-neutral voltage

Generator inter-phase voltage

Generator phase current

Generator earth current (optional)

Generator phase sequence

EXPANDABLE MEASUREMENTS:

Generator total active power (KW)

Generator total visible power (KVA)

Generator total reactive power (KVAr)

Generator average power factor (cosΦ)

HIDDEN MEASUREMENTS: Actual time

Left time for the next (maintenance)

Generator positive KWh

Generator negative KWh

Generator KVAh

Generator KVArh

Number of starter

Maximum positive vector slide

Maximum negative vector slide

PROTECTION SYSTEM: ENGINE PROTECTION:

Low oil pressure

High coolant water temperature

High oil temperature (optional)

Low/high frequency cycle

Battery charger rectifier error

Low/high accumulator voltage

Low/high fuel level (optional)

ALTERNATOR PROTECTION:

Low/high voltage

Low/high frequency

Extreme voltage

Earthling error (optional)

Reverse power

Wrong phase rotation of alternator

Excitation loss

CIRCUIT BREAKER PROTECTION:

Generator switching off error

Generator switching on error

Technical information and values are according to ISO8528, ISO3046, NEMA MG1.22, IEC 600341, BS 49995000, VDE 0530 standards. All products manufactured according to ISO9001, ISO14001, OHSAS18001, TSE, CE standards. All information given in this specification set is intended for general purposes only. Due to a policy continuous improvement AGN Technology reserves the right to amend details and specifications without

notice and all information given is subject to the AGN Technology current condition of sales.

TBA: To Be Ask TBD: To Be Determined NA: Not Available N/A: Not Applicable

MCCB TECHNICAL SPECIFICATION

Technical information and values are according to ISO8528, ISO3046, NEMA MG1.22, IEC 600341, BS 49995000, VDE 0530 standards. All products manufactured according to ISO9001, ISO14001, OHSAS18001, TSE, CE standards. All information given in this specification set is intended for general purposes only. Due to a policy continuous improvement AGN Technology reserves the right to amend details and specifications without notice and all information given is subject to the AGN Technology current condition of sales.

TBA: To Be Ask TBD: To Be Determined NA: Not Available N/A: Not Applicable

Brand Name ABB

Capacity 1000Amps

P Pole Three

Frequency 50Hz

Design Compact

Serial number 034798

NS 100N

Vi 750

Uimp 8KV

Vc-389/240

Icu 50 (V) 380/415~KA 50

440~50 500/525 ~ 40

660

690 ~ 30 Ics 75% Icu

Icw 25 KA/.5s Cat-B

Protection system

Generator switching off error

Generator switching on error

Over load

AIR CIRCUIT BREAKER SPECIFICATION

Technical information and values are according to ISO8528, ISO3046, NEMA MG1.22, IEC 600341, BS 49995000, VDE 0530 standards. All products manufactured according to ISO9001, ISO14001, OHSAS18001, TSE, CE standards. All information given in this specification set is intended for general purposes only. Due to a policy continuous improvement AGN Technology reserves the right to amend details and specifications without notice and all information given is subject to the AGN Technology current condition of sales.

TBA: To Be Ask TBD: To Be Determined NA: Not Available N/A: Not Applicable

Brand name ABB

Model E4S/f

Rated uninterrupted current (at 40 °C) Iu [A] 4000

Number of poles 4

Rated service voltage Ue [V ~] 690

Rated ultimate short-circuit breaking capacity Icu

220/230/380/400/415 V ~ [kA] 80

440 V ~ [kA] 80

500/660/690 V ~ [kA] 75

Rated short-time withstand current Icw 80

(1s) [kA] 75

(3s) [kA]

Rated short-circuit making capacity (peak value) Icm [kA] 176

Application category (in accordance with IEC 60947-2) B

Isolation behavior (in accordance with IEC 60947-2)

Overall Dimensions

Fixed: H = 418 mm - D = 302 mm L [mm] 746 Withdraw able: H = 461 - D = 396.5 mm L [mm] 774 Weights (circuit-breaker complete with releases and CT, not including accessories) Fixed [kg] 120 Withdraw able (including fixed part) [kg] 170 250

STEP- UP POWER TRANSFORMER SPECIFICATION

Technical information and values are according to ISO8528, ISO3046, NEMA MG1.22, IEC 600341, BS 49995000, VDE 0530 standards. All products manufactured according to ISO9001, ISO14001, OHSAS18001, TSE, CE standards. All information given in this specification set is intended for general purposes only. Due to a policy continuous improvement AGN Technology reserves the right to amend details and specifications without notice and all information given is subject to the AGN Technology current condition of sales.

TBA: To Be Ask TBD: To Be Determined NA: Not Available N/A: Not Applicable

Capacity of power transformer 2500kVA

1 Duty Continuous to suit Max. Ambient 50°C

2 Type Oil immersed Conservator type

3 Cooling ONAN

4 Primary Voltage 0.4KV

5 Secondary Voltage 33kV or 20KV or 11 KV or as per client demand

6 Frequency 50 Hz

7 No. of phase 3

8 Winding Cu wound

9 Vector Group YNd11

10 Primary Connection Delta

11 Secondary Connection Star

12 Tapping ± 7.5% in steps of 2.5%

13 Insulation class of winding Class A

14 Temperature rise Deg. C

Top oil 50 ∙C

Winding 55 .C

15 % Impedance 7.5% +IEC TOL.

16 No load losses 4.5 KW + IEC TOL.

17 HV termination Side mounted cable box

18 LV termination Side mounted cable box

19 Applicable Standards IEC 60076

20 Over all dimension 1350*1500*1500 mm

21 Total Weight 7312 KG

22 Accessories Terminal marking plates

Tap Switch (Off- load)

Rating Plate

Cooling fan/Radiators

2 No’s earthling terminals

Lifting lugs

Oil level gauge

Drain valve

Top filling hole & plug

Thermometer with max. pointer

Pressure relief device

OTI, WTI, Bucholz Relay

SF6 RMU TECHNICAL DETAILS

Technical information and values are according to ISO8528, ISO3046, NEMA MG1.22, IEC 600341, BS 49995000, VDE 0530 standards. All products manufactured according to ISO9001, ISO14001, OHSAS18001, TSE, CE standards. All information given in this specification set is intended for general purposes only. Due to a policy continuous improvement AGN Technology reserves the right to amend details and specifications without notice and all information given is subject to the AGN Technology current condition of sales.

TBA: To Be Ask TBD: To Be Determined NA: Not Available N/A: Not Applicable

2 no’s of 630Amp triple pole, single break, 3- position (“ON”, “OFF” and “EARTH”) ring main switches, each with independent manually charged spring mechanism and fully rated earth switch with provision for earth and test of the cable.

2 no’s of air insulated cable boxes and cable clams suitable for a 3 – core cable up to 300mm². 1 no 250 Amps triple pole, vacuum circuit breaker, with independent manually charged spring mechanism and fully rated earth switch with provision for earth and test of the cable.

1 no air insulated cable box and clamp suitable for a 3- core cable up to 185mm².

1 no mimic diagram on front panel, complete with status indicator. 1 set of positive standard mechanical interlocks. 1 set of current transformer for relay protection.

1 no ABEVA make self powered relay type: MICOM P124 for O/C & E/F protection.

1 no 24V DC shunt trip coil for remote tripping of circuit breaker.

1 set of fully interlocked test access cover.

2 no’s of neon indicator lamps /phase comparator sockets for each ring switch.

1 no stud for earthling connection.

1 no pressure indicator and SF6 recharging facility.

1 no “PULL TO TRIP” mechanism (Suitable shrouded).

1 set of auxiliary terminal.

1 no operating handle.

1 no earth fault indicator, electrical Auto reset (240V AC), complete with solid core current transformer.

VACUUM CIRCUIT BREAKER (VCB) TECHNICAL SPECIFICATIONS

Technical information and values are according to ISO8528, ISO3046, NEMA MG1.22, IEC 600341, BS 49995000, VDE 0530 standards. All products manufactured according to ISO9001, ISO14001, OHSAS18001, TSE, CE standards. All information given in this specification set is intended for general purposes only. Due to a policy continuous improvement AGN Technology reserves the right to amend details and specifications without notice and all information given is subject to the AGN Technology current condition of sales.

TBA: To Be Ask TBD: To Be Determined NA: Not Available N/A: Not Applicable

DESCRRIPTION UNIT SPECIFICATION

Rated voltage KV 20

Service voltage KV 20

Rated frequency HZ 50

Rated insulation level (one min. 50Hz withstand voltage)

KV rms 28

Impulse withstand voltage (1.2/50 micro-sec. wave) KV peak

KV peak 75

3 second withstand current KA rms 20

Peak withstand current KA peak 63

Internal arc withstand current (IEC 60298 app. A) (1 second)

KA rms 25

Bus-bar rated current A 630

Auxiliary voltage

for spring loading 220V 50HZ

For protective relays, control, signaling

24V 50 HZ

For heating 220V 50HZ

Current transformer (CT) 3 No. ring type (Multiple CT)

150/5A(for metering) and 150/1A(for protection)

Potential Transformer (PT) 2 No.

20/0.4KV (Class0.5,50 VA)

Protection system

Earth fault relay Over Current relay for 3 phase (RED, YELLOW, BLUE) Master trip relay (VAJ relay) Trip current supervision relay

LOW VOLTAGE CABLE TECHNICAL DETAILS

Technical information and values are according to ISO8528, ISO3046, NEMA MG1.22, IEC 600341, BS 49995000, VDE 0530 standards. All products manufactured according to ISO9001, ISO14001, OHSAS18001, TSE, CE standards. All information given in this specification set is intended for general purposes only. Due to a policy continuous improvement AGN Technology reserves the right to amend details and specifications without notice and all information given is subject to the AGN Technology current condition of sales.

TBA: To Be Ask TBD: To Be Determined NA: Not Available N/A: Not Applicable

1 Cable Type Low voltage cable

2 Size of cable(Core*Area in mm²)

1*630

3 Applicable Standard IEC60502

4 Suitable of earthed/Unearthed system

Earthed/unearthed system

5 Voltage grade (KV) KV 0.6/1 KV

6 Maximum rated conductor temperature

∙C 105 ∙C

7 Max. Allowed conductor temperature during short current

∙C 250 ∙C

8 Continuous current carrying capacity when Load In

In Air 745

In Ground 1050

In Duct 1050

9 Conductor

Material Annelid copper

Shape Standard circular conductor

Cross section area 630

10 Insulation

Materials XLPE compound, as per ISO7098

Normal thickness of insulation mm 2.00

11 Outer Sheath

Materials PVC

Extruded or Wrapped Extruded

Thickness of sheath (Min.) mm 2.10

Color of sheath Black

12 Overall diameter of cable mm 37.0

13 Approx. Net Weight of cable Kg/Km

3869.0

14 Overall quantity tolerance % ±5%

15 Recommended minimum bending radius

mm 740

16 Max. DC resistance at 20∙C Ohm/Km

0.047

17 Max. AC resistance at 70∙C Ohm/Km

FUEL TANK DESIGN SPECIFICATION

Technical information and values are according to ISO8528, ISO3046, NEMA MG1.22, IEC 600341, BS 49995000, VDE 0530 standards. All products manufactured according to ISO9001, ISO14001, OHSAS18001, TSE, CE standards. All information given in this specification set is intended for general purposes only. Due to a policy continuous improvement AGN Technology reserves the right to amend details and specifications without notice and all information given is subject to the AGN Technology current condition of sales.

TBA: To Be Ask TBD: To Be Determined NA: Not Available N/A: Not Applicable

Capacity 10,000 Gallons

Shape Cylindrical

Thickness 8mm

Port Inlet, Outlet (For Overflow)

Bottom stand 1000mm Ht.

Material Grade A-36, Mild Steel

Painting System

The fuel tank shall be light in color to minimize heating of the fuel by radiant heat sources. Any plating or paint materials shall not be degraded by contact with the fuel

Accessories

Fuel drain (The fuel drain assembly shall be constructed at the bottom side of the fuel tank) Fuel Gauge Man hole Air Vent Ladder Walking Platform at the top