PROPOSED FIT-OUT & IMPROVEMENTS€¦ · contact: scott d'entremont gyp gypsum sab sound attenuating...

14
PROJECT ITEM FURNISHED BY INSTALLED BY NOTES EXISTING MCM MCM-SUB OWNER OTHER MCM-SUB OWNER OTHER 01 GENERAL 02 SITEWORK 03 CONCRETE 04 MASONRY 05 METALS 06 WOOD & PLASTICS 07 THERMAL & MOISTURE PROTECTION 08 DOORS & WINDOWS 09 FINISHES 10 SPECIALTIES 11 EQUIPMENT 12 FURNISHINGS PERMITS ROUGH CARPENTRY AND BLOCKING FINISH CARPENTRY AND TRIM REINFORCED GYPSUM PANELS CASEWORK DISPOSAL SERVICES FINAL CLEANUP WATERPROOFING AND DAMPROOFING INSULATION GRANITE TILE STUCCO SYNTHETIC STUCCO SYSTEMS ALUMINUM SOFFITS MEMBRANE ROOFING SCUPPERS INTERNAL RAIN DRAINAGE ROOF ACCESSORIES JOINT SEALANTS AND FILLERS STEEL AND WOOD DOORS AND FRAMES ALUMINUM ENTRANCES ALUMINUM WINDOWS FINISH HARDWARE GLASS & GLAZING ALUMINUM STOREFRONT GYPSUM BOARD WALLS & CEILINGS ACOUSTIC CEILINGS CERAMIC TILE RESILIENT FLOOR AND BASES CARPET WALL COVERINGS PAINTING PRIVACY CURTAINS EXTERIOR LOUVERS EXTERIOR SIGNAGE INTERIOR SIGNAGE METAL LOCKERS FIRE EXTINGUISHERS AND CABINETS TOILET ACCESSORIES SURFACE MOUNTED KEY BOX CURTAIN TRACK APPLIANCES ENTRANCE MATS LOUVERED BLINDS WINDOW TREATMENT 13 SPECIAL CONSTRUCTION 14 CONVEYING SYSTEMS 15 MECHANICAL SYSTEMS 16 ELECTRICAL FURNITURE FIRE PROTECTION PLUMBING PIPING PLUMBING FIXTURES HVAC UNIT HVAC DUCTWORK HVAC DIFFUSERS & REGISTERS SERVICE & TRANSFORMER ELECTRICAL PANELS BRANCH WIRING LIGHT FIXTURES DATA & COMMUNICATION SYSTEM SMOKE ALARMS ANNUNCIATOR PANEL EMERGENCY GENERATOR SECURITY SYSTEM BACK FLOW PREVENTORS OPERATING ROOM LIGHTS REVERSE OSMOSIS SYSTEM & FILTRATION ALL OFFICE MEDIA & EQUIPMENT TENANT TENANT TENANT TO PROVIDE IN LEASE SPACE TENANT TO PROVIDE IN LEASE SPACE TENANT TO PROVIDE IN LEASE SPACE TENANT TO PROVIDE IN LEASE SPACE TENANT TO PROVIDE IN LEASE SPACE TENANT TO PROVIDE IN LEASE SPACE TENANT TO PROVIDE IN LEASE SPACE TENANT TO PROVIDE IN LEASE SPACE 0 Room name 101 150 SF 101 A101 1 SIM Name Elevation 1 A101 SIM SECTION SYMBOL LEVEL TAG CALLOUT SYMBOL DOOR NUMBER COL CENTERS ROOM NAME W/ NUMBER & SQ. FT. 1t WINDOW NUMBER 0 A WALL TYPE 1 REVISIONS 1 EQUIPMENT NUMBER WALL ELEVATION X X.XX 4 3 2 1 JET HANGAR 1 AREA OF WORK MCMUSA, LLC. 181 WELLS AVE., NEWTON, MA 02459 TEL.(617)969-1900 FAX(617)964-8297 All ideas, designs, arrangements, drawings and specifications are owned by, and the property of this office and were created, evolved and developed for use on, and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm or corporation for any purpose whatsoever without the written permission of this design office. C 2008, MCMUSA, LLC. All sub-trades and fabricators shall be responsible for field verifying all dimensions to ensure proper location and fit of all field construction and manufactured items called for or shown in this drawing. NOTE: NO. DATE REVISIONS BY DATE: SCALE: DRAWN: CHECKED: DRAWING NO: PROJECT NO: DATE: DRAWING TITLE: PROJECT: THE APPROVAL OF THIS DOCUMENT CONSTITUTES AN ACCEPTANCE OF ALL ITS CONTENT. DESIGN CHANGES AFTER THIS APPROVAL REQUESTED BY THE CLIENT WILL BE SUBJECT TO ADDITIONAL CHARGES APPROVED APPROVED AS NOTED DATE: BY: 492 Sutton St. North Andover, MA 01845 As indicated 07120 T 1.0 04/25/08 LD GC 04/25/08 ISSUE FOR CONSTRUCTION LAWRENCE MUNICIPAL AIRPORT HANGAR JET HANGAR 1 Title Sheet TYPICAL ABBREVIATIONS SYMBOLS APPLICABLE CODES PROJECT DIRECTORY DRAWING LIST PROJECT INFORMATION LOCUS PLAN KEY PLAN POUNDS PER SQUARE FOOT UNDER COUNTER, UNDER CUT CONTRACTOR ARCHITECT T 1.0 - TITLE SHEET FAX: (617) 964-8297 TITLE SHEET CIVIL PANEL PREFINISHED POUNDS PER SQUARE INCH POUND PLASTIC LAMINATE PLASTIC PROPERTY, PROPOSED PAINTED ROUGH OPENING SOLID CORE SHEET VINYL SHEET REQUIRED ROOF DRAIN REVISE, REVISION REMOVE RADIUS, RISER QUARRY TILE REINFORCE SEALANT STEEL TREAD TYPICAL TELEPHONE THROUGH TOILET TOP & BOTTOM SUSPENDED STANDARD SQUARE FEET SPECIFICATIONS SPRINKLER STAINLESS STEEL WEST WITH VENT THROUGH ROOF VINYL COMPOSITION TILE VINYL BASE VERTICAL UNFINISHED WITHOUT WELDED WIRE FABRIC WEIGHT WATERPROOFING WOOD SOUTH THRU MECH MAX MECHANICAL MAXIMUM EQUAL EXPANSION JOINT EJ EXP EXT EXTERIOR EXPANSION EQUIP EXIST ENCL ELEV ENTR EQ EL E EW ELEC ENCLOSE(D) ELEVATOR EQUIPMENT EXISTING ENTRANCE ELEVATION EACH WAY ELECTRIC(AL) EAST MISCELLANEOUS OUTSIDE DIAMETER NOT TO SCALE OC ON CENTER OD OA OPG OVERALL OPENING MIN MISC MTL NOM N NO, # NTS MTG NUMBER NOMINAL NORTH MINIMUM METAL MOUNTING VTR W/O WP WD WT WWF W W/ UC UNFIN VCT VB VERT T TYP TLT T&B APPROXIMATELY CONTROL JOINT AIR CONDITIONER CONCRETE BLOCK ACOUSTIC CEILING TILE ABOVE FINISHED FLOOR CORNER GUARD BOTTOM BOT CJ DTL DIAG DIAM DIM DR DWG D CORR CTR CG DETAIL DIAMETER DIAGONAL DOOR DRAWING DIMENSION CORRIDOR COUNTER DEEP, DEPTH CONC CONT CONTR CLR COL CB C L CLG CO CABT CLEAR CONTINUOUS CONCRETE COLUMN CONTRACTOR CENTER LINE CEILING CABINET CLEAN OUT ACT APPROX ALUM BD BLKG BLDG BM L AC AFF BOARD BLOCKING BUILDING BEAM ANGLE ALUMINUM GALV GALVANIZED HORIZONTAL HOLLOW CORE HOLLOW METAL HARDWARE, HOT WATER GENERAL CONTRACTOR HEATING, VENTILATING & AIR CONDITIONING MASONRY OPENING INSIDE DIAMETER LONG, LENGTH HB HOSE BIBB INT L,LG LAV MAT MO ID IN LAVATORY MATERIAL INTERIOR INCHES GWB GC GL H, HT HVAC HM HORIZ HC HW HEIGHT GYPSUM WALL BOARD GLASS SC SS, ST STL SUSP STL TEL SF, SQ FT SPR STD SPECS S RD RO SV SHT SLNT R REQD REM REV REINF FIRE HOSE CABINET FOUNDATION FLUORESCENT FIRE EXTINGUISHER CABINET FIN FINISH FEC FLR FLASHG FTG FOUND FLUOR FLRG FHC GA FLOORING FOOTING GAGE FLASHING FLOOR PTD PSI PSF PROP PREFIN QT PL, PLAM PNL LB PLAS OWNER INTERIOR IMPROVEMENTS NFPA 101- 2000 EDITION LIFE SAFETY CODE ASHRAE 90.1 - 2001 NFPA 13 MASS PLUMBING CODE 6TH EDITION ACCESSIBILITY CODES MECHANICAL CODE FIRE PROTECTION CODE PLUMBING CODE ELECTRICAL CODE BUILDING CODE MASSACHUSETTS BUILDING CODE 6TH ED 780 CMR NFPA 101 NFPA 72 NFPA 70 MASS ELECTRICAL CODE 6TH EDITION 521 CMR MASSACHUSETTS ARCH. ACCESS BOARD REGULATIONS REV. 2002 MASS PLUMBING CODE 6TH EDITION SQUARE FOOTAGE: 11705 SQ. FT. USE GROUP: S-2 HANGAR GROUP III JET HANGAR 1 MCMUSA, LLC. 181 WELLS AVE. NEWTON MA 02459 TEL.: (617) 969-1900 CONTACT: GREG CAVANAUGH RESPONSIBILITY SCHEDULE NF NATURAL FINISH SITE PLAN SITE DETAILS FAX: (617) 964-8297 MCMUSA, LLC. 181 WELLS AVE. NEWTON MA 02459 TEL.: (617) 969-1900 CONTACT: CAL GRAY HANGAR AT LAWRENCE MUNICIPAL AIRPORT JET HANGAR 1 PROPOSED FIT-OUT & IMPROVEMENTS 492 SUTTON ST. NORTH ANDOVER MA, 01845 FAX: (617) 964-8297 181 WELLS AVE. NEWTON MA 02459 TEL.: (617) 969-1900 CONTACT: SCOTT D'ENTREMONT GYP GYPSUM SOUND ATTENUATING INSULATION SAB MECHANICAL / PLUMBING / FIRE PROTECTION ENGINEER FAX: (617) 350-0332 SED ASSOCIATES CORP. 132 LINCOLN ST. BOSTON, MA 02111 TEL.: (617) 350-7245 CONTACT: RICK CALHOUN ELECTRICAL ENGINEER CONTACT: PETER EVANS SED ASSOCIATES CORP. FAX: (617) 350-0332 132 LINCOLN ST. BOSTON, MA 02111 TEL.: (617) 350-7245 CIVIL ENGINEER CONTACT: WILLIAM MACLEOD ANDOVER CONSULTANTS INC. 1 EAST RIVER PLACE METHUEN, MA 01844 TEL.: (978) 687-3828 PLUMBING FIRE PROTECTION HVAC ELECTRICAL ARCHITECTURAL EC1.0 - A 0.1 - A 0.2 - A 1.0 - A 1.1 - A 2.0 - A 2.1 - A 2.2 - A 3.0 - A 3.1 - A 4.0 - A 4.1 - A 5.0 - EXISTING CONDITIONS & DEMO PLAN DOOR & WINDOW SCHEDULE, WALL TYPE, GENERAL NOTE FLOOR COVERING PLAN & FINISH SCHEDULE PROPOSED SLAB PLAN PROPOSED ROOF PLAN FURNITURE PLAN FIRST FLOOR CONSTRUCTION PLAN & REFLECTIVE CEILING PLAN AIRPLANE HANGER CONSTRUCTION PLAN & REFLECTED CEILING PLAN EXTERIOR ELEVATIONS - NORTH & EAST EXTERIOR ELEVATIONS - SOUTH & WEST INTERIOR ELEVATIONS INTERIOR ELEVATIONS INTERIOR CONSTRUCTION DETAILS P1.1 - P2.1 - P2.2 - PLUMBING FLOOR PLANS PLUMBING DETAILS PLUMBING SPECIFICATIONS F1.1 - F1.2 - FIRE PROTECTION HANGAR FLOOR PLAN & DETAILS FIRE PROTECTION OFFICE AREA FLOOR PLAN & SPECIFICATIONS H1.1 - H2.1 HVAC OFFICE AREA FLOOR PLAN HVAC SPECIFICATIONS E0.1 - E1.0 - E1.1 - E2.0 - E2.1 - E3.0 - E4.0 - E5.0 - ELECTRICAL SYMBOLS, ABBREV'S AND GNL NOTE ELECTRICAL FIRST & SECOND FLOOR POWER PROPOSED PLANS ELECTRICAL HANGAR POWER / LIGHTING PROPOSED PLANS ELECTRICAL RISER DIAGRAMS AND WIRING DETAILS ELECTRICAL WIRING DIAGRAMS & PARTIAL PLANS ELECTRICAL DETAILS "I" ELECTRICAL SCHEDULES ELECTRICAL SPECIFICATIONS CONSTRUCTION TYPE: 3A 1 04/17/08 ADDENDUM MCM 1 SOLID SURFACE SDS

Transcript of PROPOSED FIT-OUT & IMPROVEMENTS€¦ · contact: scott d'entremont gyp gypsum sab sound attenuating...

Page 1: PROPOSED FIT-OUT & IMPROVEMENTS€¦ · contact: scott d'entremont gyp gypsum sab sound attenuating insulation mechanical / plumbing / fire protection engineer fax: (617) 350-0332

PROJECT ITEM

FURNISHED BY INSTALLED BY NOTES

EXIS

TIN

G

MC

M

MC

M-S

UB

OW

NER

OTH

ER

MC

M-S

UB

OW

NER

OTH

ER

01 GENERAL

02 SITEWORK03 CONCRETE04 MASONRY05 METALS

06 WOOD & PLASTICS

07 THERMAL & MOISTURE PROTECTION

08 DOORS & WINDOWS

09 FINISHES

10 SPECIALTIES

11 EQUIPMENT

12 FURNISHINGS

PERMITS

ROUGH CARPENTRY AND BLOCKING

FINISH CARPENTRY AND TRIM

REINFORCED GYPSUM PANELS

CASEWORK

DISPOSAL SERVICES

FINAL CLEANUP

WATERPROOFING AND DAMPROOFING

INSULATION

GRANITE TILE

STUCCO

SYNTHETIC STUCCO SYSTEMS

ALUMINUM SOFFITS

MEMBRANE ROOFING

SCUPPERS

INTERNAL RAIN DRAINAGE

ROOF ACCESSORIES

JOINT SEALANTS AND FILLERS

STEEL AND WOOD DOORS AND FRAMES

ALUMINUM ENTRANCES

ALUMINUM WINDOWS

FINISH HARDWARE

GLASS & GLAZING

ALUMINUM STOREFRONT

GYPSUM BOARD WALLS & CEILINGS

ACOUSTIC CEILINGS

CERAMIC TILE

RESILIENT FLOOR AND BASES

CARPET

WALL COVERINGS

PAINTING

PRIVACY CURTAINS

EXTERIOR LOUVERS

EXTERIOR SIGNAGE

INTERIOR SIGNAGE

METAL LOCKERS

FIRE EXTINGUISHERS AND CABINETS

TOILET ACCESSORIES

SURFACE MOUNTED KEY BOX

CURTAIN TRACK

APPLIANCES

ENTRANCE MATS

LOUVERED BLINDS

WINDOW TREATMENT

13 SPECIAL CONSTRUCTION14 CONVEYING SYSTEMS15 MECHANICAL SYSTEMS

16 ELECTRICAL

FURNITURE

FIRE PROTECTION

PLUMBING PIPING

PLUMBING FIXTURES

HVAC UNIT

HVAC DUCTWORK

HVAC DIFFUSERS & REGISTERS

SERVICE & TRANSFORMER

ELECTRICAL PANELS

BRANCH WIRING

LIGHT FIXTURES

DATA & COMMUNICATION SYSTEM

SMOKE ALARMS ANNUNCIATOR PANEL

EMERGENCY GENERATOR

SECURITY SYSTEM

BACK FLOW PREVENTORS

OPERATING ROOM LIGHTS

REVERSE OSMOSIS SYSTEM & FILTRATION

ALL OFFICE MEDIA & EQUIPMENT

TEN

ANT

TEN

ANT

TENANT TO PROVIDE IN LEASE SPACE

TENANT TO PROVIDE IN LEASE SPACE

TENANT TO PROVIDE IN LEASE SPACE

TENANT TO PROVIDE IN LEASE SPACE

TENANT TO PROVIDE IN LEASE SPACE

TENANT TO PROVIDE IN LEASE SPACE

TENANT TO PROVIDE IN LEASE SPACE

TENANT TO PROVIDE IN LEASE SPACE

0

Room name101

150 SF

101

A1011

SIM

NameElevation

1A101

SIMSECTION SYMBOL

LEVEL TAG

CALLOUT SYMBOL

DOOR NUMBER

COL CENTERS

ROOM NAMEW/ NUMBER & SQ. FT.

1t WINDOW NUMBER

0

A WALL TYPE

1 REVISIONS

1 EQUIPMENT NUMBER

WALL ELEVATIONX

X.XX4

3

2

1

JET HANGAR 1

AREAOF

WORK

MCMUSA, LLC.181 WELLS AVE., NEWTON, MA 02459TEL.(617)969-1900 FAX(617)964-8297

All ideas, designs, arrangements, drawings andspecifications are owned by, and the propertyof this office and were created, evolved anddeveloped for use on, and in connection withthe specified project. None of such ideas,designs, arrangements or plans shall be usedby or disclosed to any person, firm orcorporation for any purpose whatsoeverwithout the written permission of this designoffice.

C 2008, MCMUSA, LLC.

All sub-trades and fabricators shall be responsible for field verifying all dimensions to ensureproper location and fit of all field construction and manufactured items called for or shown inthis drawing.

NOTE:

NO. DATE REVISIONS BY

DATE:

SCALE:

DRAWN:

CHECKED:

DRAWING NO:

PROJECT NO:

DATE:

DRAWING TITLE:

PROJECT:

THE APPROVAL OF THIS DOCUMENT CONSTITUTES ANACCEPTANCE OF ALL ITS CONTENT. DESIGN CHANGES AFTERTHIS APPROVAL REQUESTED BY THE CLIENT WILL BE SUBJECTTO ADDITIONAL CHARGES

APPROVED

APPROVED AS NOTED DATE:

BY:

492 Sutton St.North Andover, MA 01845

As indicated

07120

T 1.004/25/08

LD

GC

04/25/08ISSUE FOR CONSTRUCTION

LAWRENCEMUNICIPALAIRPORT HANGARJET HANGAR 1

Title Sheet

TYPICAL ABBREVIATIONS

SYMBOLS APPLICABLECODES

PROJECTDIRECTORY

DRAWING LISTPROJECTINFORMATION

LOCUS PLAN

KEYPLAN

POUNDS PER SQUARE FOOT

UNDER COUNTER, UNDER CUT

CONTRACTOR

ARCHITECT

T 1.0 - TITLE SHEET

FAX: (617) 964-8297

TITLE SHEET

CIVIL

PANEL

PREFINISHED

POUNDS PER SQUARE INCHPOUND

PLASTIC LAMINATEPLASTIC

PROPERTY, PROPOSED

PAINTED

ROUGH OPENING

SOLID CORESHEET VINYLSHEET

REQUIRED

ROOF DRAINREVISE, REVISION

REMOVE

RADIUS, RISER

QUARRY TILE

REINFORCE

SEALANT

STEEL

TREADTYPICAL

TELEPHONETHROUGHTOILETTOP & BOTTOM

SUSPENDED

STANDARDSQUARE FEET

SPECIFICATIONSSPRINKLER

STAINLESS STEEL

WESTWITH

VENT THROUGH ROOFVINYL COMPOSITION TILEVINYL BASEVERTICAL

UNFINISHED

WITHOUT

WELDED WIRE FABRICWEIGHT

WATERPROOFINGWOOD

SOUTH

THRU

MECHMAX

MECHANICALMAXIMUM

EQUAL

EXPANSION JOINTEJEXPEXT EXTERIOR

EXPANSION

EQUIPEXIST

ENCLELEV

ENTREQ

EL

EEWELEC

ENCLOSE(D)ELEVATOR

EQUIPMENTEXISTING

ENTRANCE

ELEVATION

EACH WAYELECTRIC(AL)

EAST

MISCELLANEOUS

OUTSIDE DIAMETER

NOT TO SCALE

OC ON CENTER

ODOA

OPG

OVERALL

OPENING

MINMISC

MTL

NOMN

NO, #NTS

MTG

NUMBER

NOMINALNORTH

MINIMUMMETAL

MOUNTING

VTR

W/O

WPWD

WTWWFWW/

UCUNFIN

VCTVBVERT

TTYP

TLTT&B

APPROXIMATELY

CONTROL JOINT

AIR CONDITIONER

CONCRETE BLOCK

ACOUSTIC CEILING TILE

ABOVE FINISHED FLOOR

CORNER GUARD

BOTTOMBOT

CJ

DTLDIAGDIAMDIMDRDWG

D

CORRCTR

CG

DETAIL

DIAMETERDIAGONAL

DOORDRAWING

DIMENSION

CORRIDORCOUNTER

DEEP, DEPTH

CONC

CONTCONTR

CLRCOL

CB

C LCLGCO

CABT

CLEAR

CONTINUOUS

CONCRETECOLUMN

CONTRACTOR

CENTER LINECEILING

CABINET

CLEAN OUT

ACT

APPROXALUM

BDBLKG

BLDGBM

L

ACAFF

BOARDBLOCKING

BUILDINGBEAM

ANGLEALUMINUM

GALV GALVANIZED

HORIZONTAL

HOLLOW COREHOLLOW METAL

HARDWARE, HOT WATER

GENERAL CONTRACTOR

HEATING, VENTILATING &AIR CONDITIONING

MASONRY OPENING

INSIDE DIAMETER

LONG, LENGTH

HB HOSE BIBB

INT

L,LG

LAV

MATMO

IDIN

LAVATORY

MATERIAL

INTERIOR

INCHES

GWBGCGL

H, HT

HVAC

HMHORIZ

HC

HW

HEIGHT

GYPSUM WALL BOARD

GLASS

SC

SS, ST STL

SUSPSTL

TEL

SF, SQ FTSPR

STD

SPECSS

RDRO

SVSHTSLNT

R

REQDREM

REV

REINF

FIRE HOSE CABINET

FOUNDATION

FLUORESCENT

FIRE EXTINGUISHER CABINETFIN FINISHFEC

FLRFLASHG

FTGFOUND

FLUORFLRG

FHC

GA

FLOORING

FOOTING

GAGE

FLASHINGFLOOR

PTD

PSIPSF

PROPPREFIN

QT

PL, PLAM

PNL

LB

PLAS

OWNERINTERIOR IMPROVEMENTS

NFPA 101- 2000 EDITIONLIFE SAFETY CODE

ASHRAE 90.1 - 2001

NFPA 13

MASS PLUMBING CODE 6TH EDITION

ACCESSIBILITY CODES

MECHANICAL CODE

FIRE PROTECTION CODE

PLUMBING CODE

ELECTRICAL CODE

BUILDING CODEMASSACHUSETTSBUILDING CODE6TH ED 780 CMR

NFPA 101NFPA 72NFPA 70

MASS ELECTRICAL CODE 6TH EDITION

521 CMR MASSACHUSETTS ARCH.ACCESS BOARD REGULATIONSREV. 2002

MASS PLUMBING CODE 6TH EDITION

SQUARE FOOTAGE: 11705 SQ. FT.

USE GROUP: S-2HANGAR GROUP III

JET HANGAR 1

MCMUSA, LLC.181 WELLS AVE.NEWTON MA 02459TEL.: (617) 969-1900CONTACT: GREG CAVANAUGH

RESPONSIBILITY SCHEDULE

NF NATURAL FINISH

SITE PLANSITE DETAILS

FAX: (617) 964-8297

MCMUSA, LLC.181 WELLS AVE.NEWTON MA 02459TEL.: (617) 969-1900CONTACT: CAL GRAY

HANGAR AT LAWRENCE MUNICIPAL AIRPORTJET HANGAR 1

PROPOSED FIT-OUT & IMPROVEMENTS492 SUTTON ST.

NORTH ANDOVER MA, 01845

FAX: (617) 964-8297

181 WELLS AVE.NEWTON MA 02459TEL.: (617) 969-1900CONTACT: SCOTT D'ENTREMONT

GYP GYPSUM

SOUND ATTENUATING INSULATIONSAB

MECHANICAL /PLUMBING / FIREPROTECTIONENGINEER FAX: (617) 350-0332

SED ASSOCIATES CORP.132 LINCOLN ST.BOSTON, MA 02111TEL.: (617) 350-7245CONTACT: RICK CALHOUN

ELECTRICALENGINEER

CONTACT: PETER EVANS

SED ASSOCIATES CORP.

FAX: (617) 350-0332

132 LINCOLN ST.BOSTON, MA 02111TEL.: (617) 350-7245

CIVILENGINEER

CONTACT: WILLIAM MACLEOD

ANDOVER CONSULTANTS INC.1 EAST RIVER PLACEMETHUEN, MA 01844TEL.: (978) 687-3828

PLUMBING

FIRE PROTECTION

HVAC

ELECTRICAL

ARCHITECTURALEC1.0 -A 0.1 -

A 0.2 -A 1.0 -A 1.1 -A 2.0 -A 2.1 -

A 2.2 -

A 3.0 -A 3.1 -A 4.0 -A 4.1 -A 5.0 -

EXISTING CONDITIONS & DEMO PLANDOOR & WINDOW SCHEDULE, WALL TYPE,GENERAL NOTEFLOOR COVERING PLAN & FINISH SCHEDULEPROPOSED SLAB PLANPROPOSED ROOF PLANFURNITURE PLANFIRST FLOOR CONSTRUCTION PLAN &REFLECTIVE CEILING PLANAIRPLANE HANGER CONSTRUCTION PLAN &REFLECTED CEILING PLANEXTERIOR ELEVATIONS - NORTH & EASTEXTERIOR ELEVATIONS - SOUTH & WESTINTERIOR ELEVATIONSINTERIOR ELEVATIONSINTERIOR CONSTRUCTION DETAILS

P1.1 -P2.1 -P2.2 -

PLUMBING FLOOR PLANSPLUMBING DETAILSPLUMBING SPECIFICATIONS

F1.1 -

F1.2 -

FIRE PROTECTION HANGAR FLOOR PLAN &DETAILSFIRE PROTECTION OFFICE AREA FLOOR PLAN &SPECIFICATIONS

H1.1 -H2.1

HVAC OFFICE AREA FLOOR PLANHVAC SPECIFICATIONS

E0.1 -E1.0 -

E1.1 -

E2.0 -

E2.1 -E3.0 -E4.0 -E5.0 -

ELECTRICAL SYMBOLS, ABBREV'S AND GNL NOTEELECTRICAL FIRST & SECOND FLOOR POWERPROPOSED PLANSELECTRICAL HANGAR POWER / LIGHTINGPROPOSED PLANSELECTRICAL RISER DIAGRAMS AND WIRINGDETAILSELECTRICAL WIRING DIAGRAMS & PARTIAL PLANSELECTRICAL DETAILS "I"ELECTRICAL SCHEDULESELECTRICAL SPECIFICATIONS

CONSTRUCTION TYPE: 3A

1 04/17/08 ADDENDUM MCM

1

SOLID SURFACESDS

Page 2: PROPOSED FIT-OUT & IMPROVEMENTS€¦ · contact: scott d'entremont gyp gypsum sab sound attenuating insulation mechanical / plumbing / fire protection engineer fax: (617) 350-0332

Roof Plan26' - 1 1/2"

1 2 3 4 5 6

OPEN

EXISTING METAL CLADDING TO REMAIN

EXISTING CONCRETE FOUNDATION

Hangar Level0' - 0"

9' - 6" 5' - 0" 9' - 6" 9' - 6" 5' - 0" 9' - 6" 9' - 6" 5' - 0" 9' - 6"

4' -

1 1/

2"4'

- 0"

REMOVE STEEL CLADDING& INSULATION TO CREATEROUGH OPENING FORNEW WINDOWS

ACDFGJ

Front ElevationGrade4' - 0"

REMOVE CLADDING, INSULATION,& HORIZONTAL GIRTS ACCORDINGTO MANUFACTURER'S PLANS ANDSPECIFICATIONS

REMOVE STEEL WALLINSERT & INSULATION TOCREATE ROUGH OPENINGFOR NEW WINDOWS

8' -

0"

4' -

0"

Hangar Level0' - 0"

12' - 2" 5' - 8" 3' - 7" 5' - 8" 4' - 3" 5' - 8" 5' - 8" 4' - 3" 5' - 8" 3' - 7" 5' - 8" 12' - 2"

18' - 10 1/2"

SAW CUT FOUNDATIONWALL LEVEL WITHGRADE AT ENTRY DOOR

A JB H

OPEN

FUTURE HANGAR DOORS TO BE INSTALLED BY OTHERS

EXISTING METAL CLADDING TO REMAIN

Hangar Level0' - 0"

Roof Plan26' - 1 1/2"

123456

OPEN4' -

0"

EXISTING METAL CLADDING TO REMAIN

EXISTING CONCRETE FOUNDATION

5' - 8"6' - 0"5' - 8"

Hangar Level0' - 0"

3' - 8"

9' - 6"5' - 0"9' - 6"9' - 6"5' - 0"9' - 6"9' - 6"5' - 0"9' - 6"

4' -

0"4'

- 1

1/2"

REMOVE STEEL CLADDING &INSULATION TO CREATE ROUGHOPENING FOR NEW WINDOWS

ACDFGJ

BH

EXISTING CONCRETE SLAB ON CRUSHED STONE

EXISTING TAXIWAY

EXISTING PARKING LOT

EXISTING ROUGHOPENING FOR MAN DOOR

EXISTING ROUGHOPENING FORVEHICLE DOOR

REMOVE CLADDING,GIRTS, & INSULATIONPER MANUFACTURERSPLANS & SPECS.

EXISTING ELECTRICAL SERVICE

RELOCATE ELECTRICAL SERVICE

1 1/4" DOMESTIC WATER LINE

8" FIRE LINE

1

MCMUSA, LLC.181 WELLS AVE., NEWTON, MA 02459TEL.(617)969-1900 FAX(617)964-8297

All ideas, designs, arrangements, drawings andspecifications are owned by, and the propertyof this office and were created, evolved anddeveloped for use on, and in connection withthe specified project. None of such ideas,designs, arrangements or plans shall be usedby or disclosed to any person, firm orcorporation for any purpose whatsoeverwithout the written permission of this designoffice.

C 2008, MCMUSA, LLC.

All sub-trades and fabricators shall be responsible for field verifying all dimensions to ensureproper location and fit of all field construction and manufactured items called for or shown inthis drawing.

NOTE:

NO. DATE REVISIONS BY

DATE:

SCALE:

DRAWN:

CHECKED:

DRAWING NO:

PROJECT NO:

DATE:

DRAWING TITLE:

PROJECT:

THE APPROVAL OF THIS DOCUMENT CONSTITUTES ANACCEPTANCE OF ALL ITS CONTENT. DESIGN CHANGES AFTERTHIS APPROVAL REQUESTED BY THE CLIENT WILL BE SUBJECTTO ADDITIONAL CHARGES

APPROVED

APPROVED AS NOTED DATE:

BY:

492 Sutton St.North Andover, MA 01845

1/8" = 1'-0"

07120

EC 1.004/25/08

LD

GC

04/25/08ISSUE FOR CONSTRUCTION

LAWRENCEMUNICIPALAIRPORT HANGARJET HANGAR 1

Existing Conditions& Demolition Plan

1/8" = 1'-0"1 Existing West Elevation

1/8" = 1'-0"4 Existing South Elevation

1/8" = 1'-0"5 Existing North Elevation

1/8" = 1'-0"2 Existing East Elevation

1/8" = 1'-0"3 Existing Conditions

PROJECT

N

1 04/17/08 ADDENDUM MCM

Page 3: PROPOSED FIT-OUT & IMPROVEMENTS€¦ · contact: scott d'entremont gyp gypsum sab sound attenuating insulation mechanical / plumbing / fire protection engineer fax: (617) 350-0332

TOP

PLAN

BOTTOM

1 5/8" METALSTUDS 358ST20 @16" O.C.

1 1/2" RIGID FOAM INSULATIONUP TO 4' - 0"

STANDARD 5/8"GWB ONE SIDE

APPLIED BASE

CAULK W/ SEALANT@ BOTTOM

B PARTITION TYPE (SHOWN)SCALE : 1" = 1'-0"

TOP

PLAN

BOTTOM

3 5/8" METALSTUDS 358ST20 @16" O.C.

3 1/2" SAB INSULATION

STANDARD 5/8" GWB

APPLIED BASE

CAULK W/ SEALANT@ BOTTOM

C PARTITION TYPE (SHOWN)SCALE : 1" = 1'-0"

1/2" CEMENT BOARD

TOP

PLAN

BOTTOM

3 5/8" METALSTUDS 358ST20 @16" O.C.

3 1/2" SAB INSULATION

STANDARD 5/8"GWB BOTH SIDES

APPLIED BASE

CAULK W/ SEALANT@ BOTTOM

A PARTITION TYPE (SHOWN)SCALE : 1" = 1'-0"

C1

PARTITION TYPE - SIMILAR3 5/8 STAGGERED STUDSSCALE : 1" = 1'-0"

TOP

PLAN

BOTTOM

3 5/8" METALSTUDS 358ST20 @16" O.C.

3 1/2" SAB INSULATION

2 SHEETS STANDARD5/8" GWB BOTH SIDES

APPLIED BASE

CAULK W/ SEALANT@ BOTTOM

D PARTITION TYPE (SHOWN)SCALE : 1" = 1'-0"

A1

PARTITION TYPE - SIMILARGWB ON ONE SIDESCALE : 1" = 1'-0"

C2

PARTITION TYPE - SIMILARNO GWBSCALE : 1" = 1'-0"

2 SHEETS MOISTURERESISTANT 5/8" GWBBOTH SIDES 4' - 0" AFF

MOISTURE RESISTANT 5/8"GWB BOTH SIDES 4' - 0" AFF

MOISTURE RESISTANT 5/8"GWB UP TO 4' - 0" AFF

MOISTURE RESISTANT5/8" 4' - 0" AFF

TOP

PLAN

BOTTOM

FRAMING & GWBTO 14' - 0" AFFHANGAR LEVEL

FIRE STOPPING CAULKING

6" METALSTUDS 16" O.C.

5 1/2" SAB INSULATION

STANDARD 5/8"GWB BOTH SIDES

APPLIED BASE

CAULK W/ SEALANT@ BOTTOM

E1 HR FIRE RATEDPARTITION TYPE (SHOWN)SCALE : 1" = 1'-0"

MOISTURE RESISTANT 5/8"GWB BOTH SIDES 4' - 0" AFF

E1

1 HR FIRE RATEDPARTITION TYPE - SIMILAR5/8" CEMENT BOARD ONESIDE (GWB ONE SIDE ONLY)SCALE : 1" = 1'-0"

E2

2 HR FIRE RATEDPARTITION TYPE - SIMILARADD 1 SHEET 5/8" GWBBOTH SIDESSCALE : 1" = 1'-0"

FRAMING & GWB TOUNDERSIDE OF DECK

ACOUSTICAL SEALANTACOUSTICAL SEALANTACOUSTICAL SEALANT

A2

PARTITION TYPE - SIMILAR1 HR FIRE RATEDSCALE : 1" = 1'-0"

FRAMING & GWB TOUNDERSIDE OF DECK

ACOUSTICAL SEALANT

FRAMING & GWB TOUNDERSIDE OF DECK

FRAMING & GWB TOUNDERSIDE OF DECK

1

1

1

1. INSTALL 3/4" FIRE RATED PLYWOOD BLOCKING FOR ALL HARDWARE,MILLWORK, AND ACCESSORIES

2. USE CEMENT BOARD BEHIND TILE ONLY. USE MOISTER RESISTANT 5/8" GWBON REMAINDER OF PARTITION

3. ALL TRIM FOR WOOD DOORS PAINT TO MATCH WALL

4. ALL TRIM FOR STEEL DOORS PAINT TO MATCH DOOR

GENERAL NOTES:

1

Tag ModelDoor Hardware Selections

Key Name Manufacturer

OCDoor Closer

Type Style Finish Comments

PADoor Lever

Overhead

Passage Set

PRDoor Lever Privacy Set

STDoor Lever Storage Set

OFDoor Lever Office Set

LCN

Schlage

Schlage

Schlage

Schlage

4010DA 26D

26D

26D

26D

26D

26D

26D

ND50PD

ND10S

ND40S

ND80PD

FSDoor Stop Floor Stop Ives FS436

PHExit Device Panic Hardware Precision (Stanley) 2000 Series

26DWSDoor Stop Wall Stop Ives 407CCV

ENDoor Lever Entrance Set Schlage 26DAthens (ATH) ND53PD

26DBHHinge Butt Hinge Stanley FBB - 179 Full Mortise, Anti-Friction Bearing

ALSLSilencer Rubber Hager

Athens (ATH)

Athens (ATH)

Athens (ATH)

Athens (ATH)

1 5Door Hardware PackagesGROUP 3

Door Closer

2 4 6 7

OC

SL SL

OFDoor Lever PA PR

OC

ST

PH

BHHinge

Silencer

BH BH BH BH

SL SL SL

WSDoor Stop WS

Exit Device

EN

OC

SL

OF

BH

WS

OC

SL

OF

BH

FS WS WS

ST

BH

SL

WS

OC

8

DOOR TYPES

FRAME TYPES

TYPE A

TYPE A-1

TYPE B

BIRCH VENEER

HOLLOW METAL

ALUM. & GLASS

TYPE 1AKNOCK DOWN

TYPE 1BWELDED

TYPE 2WELDED

7' -

0"

3' - 0" 3' - 0"

7' -

2"

3' - 0"

7' -

2"

3' - 0"

TYPE 3WELDED

7' -

2"

6' - 0"

SEE ELEV.FOR ALUM.SPACING

NO DOOR

TYPE 4ALUMINUM

7' -

2"

3' - 0"

MCMUSA, LLC.181 WELLS AVE., NEWTON, MA 02459TEL.(617)969-1900 FAX(617)964-8297

All ideas, designs, arrangements, drawings andspecifications are owned by, and the propertyof this office and were created, evolved anddeveloped for use on, and in connection withthe specified project. None of such ideas,designs, arrangements or plans shall be usedby or disclosed to any person, firm orcorporation for any purpose whatsoeverwithout the written permission of this designoffice.

C 2008, MCMUSA, LLC.

All sub-trades and fabricators shall be responsible for field verifying all dimensions to ensureproper location and fit of all field construction and manufactured items called for or shown inthis drawing.

NOTE:

NO. DATE REVISIONS BY

DATE:

SCALE:

DRAWN:

CHECKED:

DRAWING NO:

PROJECT NO:

DATE:

DRAWING TITLE:

PROJECT:

THE APPROVAL OF THIS DOCUMENT CONSTITUTES ANACCEPTANCE OF ALL ITS CONTENT. DESIGN CHANGES AFTERTHIS APPROVAL REQUESTED BY THE CLIENT WILL BE SUBJECTTO ADDITIONAL CHARGES

APPROVED

APPROVED AS NOTED DATE:

BY:

492 Sutton St.North Andover, MA 01845

As indicated

07120

A 0.104/25/08

LD

GC

04/25/08ISSUE FOR CONSTRUCTION

LAWRENCEMUNICIPALAIRPORT HANGARJET HANGAR 1

Door & WindowSchedule, WallTypes, GeneralNotes

Door ScheduleNo. Level From To Swing Material Finish Frame Type Door Type Hardware Set Comments

1 Level 1 Exterior Entry LHRB Laminated Safety Glass White Anodized 4 B 8 See Storefront Specs2 Level 1 Corridor 103 Private Office RH Solid Core Wood Birch Veneer Color Match PL - 1 1B A 13 Level 1 Corridor 103 Repair / Maintenace Shop RH Solid Core Wood Birch Veneer Color Match PL - 1 1B A 3 Positive Latch

Required4 Hangar Level Repair / Maintenace Shop Mechanical Room RH Steel PT - 6 1B A-1 65 Hangar Level Repair / Maintenace Shop Parts Room LH Steel PT - 6 1B A-1 66 Hangar Level Repair / Maintenace Shop Hangar Up Steel PT - 67 Hangar Level Repair / Maintenace Shop Hangar RH Steel PT - 6 1B A-1 2 Positive Latch

Required8 Level 1 Corridor 103 Aircraft Sales LH Solid Core Wood Birch Veneer Color Match PL - 1 1B A 19 Level 1 Kitchen Janitor Closet LH Solid Core Wood Birch Veneer Color Match PL - 1 1B A 610 Level 1 Kitchen Toilet 111 RH Solid Core Wood Birch Veneer Color Match PL - 1 1B A 511 Level 1 Lobby Hangar RH Laminated Safety Glass Clear Anodized 4 B 4 Positive Latch

Required. SeeStorefront Specs

12 Level 1 Lobby Office LH Solid Core Wood Birch Veneer Color Match PL - 1 1B A 113 Level 1 Corridor 114 Office (Shared) RH Solid Core Wood Birch Veneer Color Match PL - 1 1B A 114 Hangar Level Hangar Air Commpressor Closet RH Steel PT - 6 1B A-1 615 Hangar Level Exterior Hangar LHRB Steel PT - 6 1A A-1 816 Hangar Level Exterior Hangar RHRB Steel PT - 6 1A A-1 816 Hangar Level Hangar Toilet 118 LH Steel PT - 6 1B A-1 5 Positive Latch17 Hangar Level Hangar Electrical Closet DH Steel PT - 6 3 A-1 7 45 Minute Fire Rated18 Level 1 Pilot Lounge Corridor 103 PT - 1 2 Cased Opening19 Level 1 Hall Kitchen PT - 1 2 Cased Opening20 Level 1 Reception Corridor 114 PT - 1 2 Cased Opening21 Level 1 Corridor 114 Classroom PT - 1 2 Cased Opening

Window ScheduleType Mark Count Level Type Frame Type Model Head Height Sill Height Comments

1 8 Level 1 68" x 48" Aluminum Hopper Style Operable Lower Leaf Double Glazed Safety Glass 8' - 0" 4' - 0" Privacy Tinting On Windows. Include Screen.2 12 Level 1 68" x 68" Aluminum Fixed Double Glazed 22' - 2" 16' - 6"3 1 Level 1 36" x 48" Wood Fixed Single Glazed 7' - 0" 3' - 0" Wood Stained to Match PL - 14 1 Level 1 60" x 36" Wood Fixed Single Glazed 6' - 6" 3' - 6" Wood Stained to Match PL - 15 6 Hangar Level 60" x 48" Aluminum Fixed Double Glazed 22' - 0" 18' - 0"6 1 Hangar Level 146" x 65" Aluminum Fixed Double Glazed 12' - 8" 7' - 3" Fit To Existing Opening.

1" = 1'-0"1 Wall Details

7 Hangar Level 144" x 96" Aluminum Fixed Double Glazed 8' - 6" 0' - 6" Fit Between Walls8 Hangar Level Aluminum 8' - 6" 0' - 6"9

144" x 96"12

10Level 1 Aluminum 10' - 4" 3' - 6"115 1/2" x 82"1 Three Equal Panels

Fixed Double GlazedLaminated Safety Glass

Front Elevation Grade Aluminum 8' - 0" 0' - 0"226 1/2" x 96"1 Five Equal Vertical Sections. See A 3.1 #1 For Panel SizesDouble Glazed Safety Glass

1

1 04/17/08 ADDENDUM MCM

1

1

1/2" = 1'-0"2 Door Details

Page 4: PROPOSED FIT-OUT & IMPROVEMENTS€¦ · contact: scott d'entremont gyp gypsum sab sound attenuating insulation mechanical / plumbing / fire protection engineer fax: (617) 350-0332

DN

ACDFGJ

5

6

58 SF

TOILET118

125 SF

AIRCRAFTSALES

105

106 SF

PRIVATEOFFICE

104

174 SF

PILOTLOUNGE

10259 SF

CORRIDOR103

96 SF

MECHANICALROOM

107

144 SF

PARTSROOM

108

404 SF

REPAIR /MAINTENACE

SHOP106

20 SF

AIRCOMPRESSOR

CLOSET119

39 SF

ELECTRICALCLOSET

120

80 SF

CLASSROOM115

234 SF

LOBBY101

89 SF

RECEPTION113

40 SF

CORRIDOR114

168 SF

OFFICE112

459 SF

OFFICE(SHARED)

116

8 SF

J.C.109

52 SF

KITCHEN11058 SF

TOILET111

TO REMAINASUNFINISHEDCONCRETE

TO REMAINAS

UNFINISHEDCONCRETE

FLOOR COVERING LEGEND

CPT - 1 Bolyu / Chain of Events COE75

CPT - 2 Bolyu / Direct Effect DEF79

CT - 1 American Olean / Highland Ridge EvergreenHR52 18 x 18

CT - 2 American Olean / Highland Ridge DesertHR50 1" x 3" Mosaic

Polished Concrete

CT - 3 American Olean / Amiata Giallo AT51 12 x 12

CPT - 3 Bolyu / Tailored Details TLD58 Top Stitch

MANUFACTURE STYLE / COLOR COMMENTSPAINTPT - 1 SHERWIN WILLIAMS SW0011 CREWEL TAN

SHERWIN WILLIAMS SW6334 FLOWER POT

SHERWIN WILLIAMS SW0014 SHERATON SAGE

SHERWIN WILLIAMS SW6222 RIVERWAY

SHERWIN WILLIAMS SW6235 FOGGY DAY

SHERWIN WILLIAMS SW6004 MINK

SHERWIN WILLIAMS SW6006 BLACK BEAN

PT - 2

PT - 3

PT - 4

PT - 5

PT - 6

PT - 7

FINISH LEGEND

CERAMIC TILECT - 4 AMERICAN OLEAN AMIATA / GIALLO AT51 10" x 13" WALL

CT - 5 AMERICAN OLEAN AMIATA / GIALLO AT51 3" x 12" BULLNOSE

CT - 6 AMERICAN OLEAN AMIATA / GIALLO AT51 6" x 12" COVE BASE

BASEVB - 1 JOHNSONITE 80 FAWN

LAMINATEPL - 1 NEVAMAR CARMEL SAGAWOOD WM8350T

PL - 2 NEVAMAR WINTERGREEN MATRIX MR5006T

SOLID SURFACESDS - 1 CORIAN AQUA - SIERRA FAMILY

SDS - 2 AVONITE GOLDMINE K3-8495 / GLOSS

MOISTER RESISTANT

MCMUSA, LLC.181 WELLS AVE., NEWTON, MA 02459TEL.(617)969-1900 FAX(617)964-8297

All ideas, designs, arrangements, drawings andspecifications are owned by, and the propertyof this office and were created, evolved anddeveloped for use on, and in connection withthe specified project. None of such ideas,designs, arrangements or plans shall be usedby or disclosed to any person, firm orcorporation for any purpose whatsoeverwithout the written permission of this designoffice.

C 2008, MCMUSA, LLC.

All sub-trades and fabricators shall be responsible for field verifying all dimensions to ensureproper location and fit of all field construction and manufactured items called for or shown inthis drawing.

NOTE:

NO. DATE REVISIONS BY

DATE:

SCALE:

DRAWN:

CHECKED:

DRAWING NO:

PROJECT NO:

DATE:

DRAWING TITLE:

PROJECT:

THE APPROVAL OF THIS DOCUMENT CONSTITUTES ANACCEPTANCE OF ALL ITS CONTENT. DESIGN CHANGES AFTERTHIS APPROVAL REQUESTED BY THE CLIENT WILL BE SUBJECTTO ADDITIONAL CHARGES

APPROVED

APPROVED AS NOTED DATE:

BY:

492 Sutton St.North Andover, MA 01845

1/4" = 1'-0"

07120

A 0.204/25/08

LD

GC

04/25/08ISSUE FOR CONSTRUCTION

LAWRENCEMUNICIPALAIRPORT HANGARJET HANGAR 1

Floor Covering Plan& Finish Schedule

Room Finish ScheduleNumber Name N. Wall E. Wall S. Wall W. Wall Ceiling Finish Comments

101 LOBBY PT - 2 PT - 1 PT - 2 PT - 1 WOODSLAT / GWB SOFFIT: PT - 2102 PILOT LOUNGE PT - 2 PT - 1 PT - 2 PT - 1 WOODSLAT / GWB SOFFIT: PT - 2103 CORRIDOR PT - 1 PT - 1 PT - 1 PT - 1 ACT - 1104 PRIVATE OFFICE PT - 1 PT - 1 PT - 5 PT - 1 ACT - 1105 AIRCRAFT SALES PT - 4 PT - 6 PT - 4 PT - 6 ACT - 1106 REPAIR / MAINTENACE SHOP PT - 6 PT - 6 PT - 6 PT - 6 ACT - 2107 MECHANICAL ROOM PT - 6 PT - 6 PT - 6 PT - 6 ACT - 2108 PARTS ROOM PT - 6 PT - 6 PT - 6 PT - 6 ACT - 2109 J.C. PT - 1 PT - 1 PT - 1 PT - 1 ACT - 1110 KITCHEN PT - 4 PT - 4 PT - 4 PT - 4 ACT - 1111 TOILET CT - 4 / PT - 1 CT - 4 / PT - 1 CT - 4 / PT - 1 CT - 4 / PT - 1 ACT - 1 WATER RESISTANT PAINT TO BE USED w/ SEMI-GLOSS FINISH112 OFFICE PT - 1 PT - 5 PT - 1 PT - 1 ACT - 1113 RECEPTION PT - 2 PT - 1 PT - 2 PT - 1 WOODSLAT / GWB SOFFIT: PT - 2114 CORRIDOR PT - 5 PT - 1 PT - 1 PT - 1 ACT - 1115 CLASSROOM PT - 1 PT - 1 PT - 1 PT - 5 ACT - 1116 OFFICE (SHARED) PT - 1 PT - 4 PT - 1 PT - 4 ACT - 1 / GWB SOFFIT: PT - 7117 HANGAR N/A N/A PT - 2 N/A N/A118 TOILET PT - 3 PT - 3 PT - 3 PT - 3 ACT - 1 WATER RESISTANT PAINT TO BE USED w/ SEMI-GLOSS FINISH119 AIR COMPRESSOR CLOSET PT - 6 PT - 6 PT - 6 PT - 6 1 HR GWB: PT - 6120 ELECTRICAL CLOSET PT - 6 PT - 6 PT - 6 PT - 6 2 HR GWB: PT - 6

1

1 04/17/08 ADDENDUM MCM

Page 5: PROPOSED FIT-OUT & IMPROVEMENTS€¦ · contact: scott d'entremont gyp gypsum sab sound attenuating insulation mechanical / plumbing / fire protection engineer fax: (617) 350-0332

ACDFGJ

1

2

3

4

5

6

BH

0' - 0" FINISHED FLOOR ELEVATION

72' - 0"

25' -

9 1

/2"

9' -

6 1/

2"

11"

STEEL NOSING

STEEL NOSING11

"

4' -

2 1/

2"10

' - 6

"

0' - 6" FINISHED FLOOR ELEVATION

3' - 6"15' - 4 1/2"6' - 0"12' - 8" 4000 PSI CONCRETE,SMOOTH FINISH,REINFORCEMENT MESH& EXPANSION JOINTS

MCMUSA, LLC.181 WELLS AVE., NEWTON, MA 02459TEL.(617)969-1900 FAX(617)964-8297

All ideas, designs, arrangements, drawings andspecifications are owned by, and the propertyof this office and were created, evolved anddeveloped for use on, and in connection withthe specified project. None of such ideas,designs, arrangements or plans shall be usedby or disclosed to any person, firm orcorporation for any purpose whatsoeverwithout the written permission of this designoffice.

C 2008, MCMUSA, LLC.

All sub-trades and fabricators shall be responsible for field verifying all dimensions to ensureproper location and fit of all field construction and manufactured items called for or shown inthis drawing.

NOTE:

NO. DATE REVISIONS BY

DATE:

SCALE:

DRAWN:

CHECKED:

DRAWING NO:

PROJECT NO:

DATE:

DRAWING TITLE:

PROJECT:

THE APPROVAL OF THIS DOCUMENT CONSTITUTES ANACCEPTANCE OF ALL ITS CONTENT. DESIGN CHANGES AFTERTHIS APPROVAL REQUESTED BY THE CLIENT WILL BE SUBJECTTO ADDITIONAL CHARGES

APPROVED

APPROVED AS NOTED DATE:

BY:

492 Sutton St.North Andover, MA 01845

3/16" =1'-0"

07120

A 1.004/25/08

LD

GC

04/25/08ISSUE FOR CONSTRUCTION

LAWRENCEMUNICIPALAIRPORT HANGARJET HANGAR 1

Slab Plan

Page 6: PROPOSED FIT-OUT & IMPROVEMENTS€¦ · contact: scott d'entremont gyp gypsum sab sound attenuating insulation mechanical / plumbing / fire protection engineer fax: (617) 350-0332

ACDFGJ

1

2

3

4

5

6

BH

EXISTING STANDING SEAM METAL ROOF TO REMAIN

SLOPE SLOPE

PROPOSED ROOFTOP PACKAGED UNITS

NOTE: ROOF PENETRATIONS & CURB / DUNNAGE DESIGN TO BE DETERMINED

MCMUSA, LLC.181 WELLS AVE., NEWTON, MA 02459TEL.(617)969-1900 FAX(617)964-8297

All ideas, designs, arrangements, drawings andspecifications are owned by, and the propertyof this office and were created, evolved anddeveloped for use on, and in connection withthe specified project. None of such ideas,designs, arrangements or plans shall be usedby or disclosed to any person, firm orcorporation for any purpose whatsoeverwithout the written permission of this designoffice.

C 2008, MCMUSA, LLC.

All sub-trades and fabricators shall be responsible for field verifying all dimensions to ensureproper location and fit of all field construction and manufactured items called for or shown inthis drawing.

NOTE:

NO. DATE REVISIONS BY

DATE:

SCALE:

DRAWN:

CHECKED:

DRAWING NO:

PROJECT NO:

DATE:

DRAWING TITLE:

PROJECT:

THE APPROVAL OF THIS DOCUMENT CONSTITUTES ANACCEPTANCE OF ALL ITS CONTENT. DESIGN CHANGES AFTERTHIS APPROVAL REQUESTED BY THE CLIENT WILL BE SUBJECTTO ADDITIONAL CHARGES

APPROVED

APPROVED AS NOTED DATE:

BY:

492 Sutton St.North Andover, MA 01845

3/16" =1'-0"

07120

A 1.104/25/08

LD

GC

04/25/08ISSUE FOR CONSTRUCTION

LAWRENCEMUNICIPALAIRPORT HANGARJET HANGAR 1

Proposed Roof Plan

3/16" = 1'-0"1 Roof Plan

Page 7: PROPOSED FIT-OUT & IMPROVEMENTS€¦ · contact: scott d'entremont gyp gypsum sab sound attenuating insulation mechanical / plumbing / fire protection engineer fax: (617) 350-0332

REF.

DN

ACDFGJ

1

2

3

4

5

6

BH

58 SF

TOILET118

125 SF

AIRCRAFTSALES

105

106 SF

PRIVATEOFFICE

104

174 SF

PILOTLOUNGE

10259 SF

CORRIDOR103

96 SF

MECHANICALROOM

107

144 SF

PARTSROOM

108

404 SF

REPAIR /MAINTENACE

SHOP106

20 SF

AIRCOMPRESSOR

CLOSET119

NOTE: FURNITURE, EQUIPMENT, SHELVING,AND SPECIALTY FIXTURES BY TENANT

9153 SF

HANGAR117

INFILL DOOR OPENINGINSTALL NEW STEEL

DOOR & FRAME

NEW SILLCOCK

ROLL UP GARAGE DOOR

INFILL DOOR OPENINGINSTALL NEW STEELDOOR & FRAME

NEW CONCRETE SLABEPOXY FLOOR FINISH

W/ RADIANT HEAT IN FLOOR

80 SF

CLASSROOM115

58 SF

TOILET111

8 SF

J.C.109

40 SF

CORRIDOR114 459 SF

OFFICE(SHARED)

116

168 SF

OFFICE112

39 SF

ELECTRICALCLOSET

120

89 SF

RECEPTION113

52 SF

KITCHEN110

234 SF

LOBBY101GAS METER

RAMP

HANDICAP ACCESSIBLE ENTRY

HANDICAPACCESSIBLEENTRY

ICE

ALL SHELVINGBY TENANT

N

10

A 5.0

1

1

MCMUSA, LLC.181 WELLS AVE., NEWTON, MA 02459TEL.(617)969-1900 FAX(617)964-8297

All ideas, designs, arrangements, drawings andspecifications are owned by, and the propertyof this office and were created, evolved anddeveloped for use on, and in connection withthe specified project. None of such ideas,designs, arrangements or plans shall be usedby or disclosed to any person, firm orcorporation for any purpose whatsoeverwithout the written permission of this designoffice.

C 2008, MCMUSA, LLC.

All sub-trades and fabricators shall be responsible for field verifying all dimensions to ensureproper location and fit of all field construction and manufactured items called for or shown inthis drawing.

NOTE:

NO. DATE REVISIONS BY

DATE:

SCALE:

DRAWN:

CHECKED:

DRAWING NO:

PROJECT NO:

DATE:

DRAWING TITLE:

PROJECT:

THE APPROVAL OF THIS DOCUMENT CONSTITUTES ANACCEPTANCE OF ALL ITS CONTENT. DESIGN CHANGES AFTERTHIS APPROVAL REQUESTED BY THE CLIENT WILL BE SUBJECTTO ADDITIONAL CHARGES

APPROVED

APPROVED AS NOTED DATE:

BY:

492 Sutton St.North Andover, MA 01845

3/16" =1'-0"

07120

A 2.004/25/08

LD

GC

04/25/08ISSUE FOR CONSTRUCTION

LAWRENCEMUNICIPALAIRPORT HANGARJET HANGAR 1

Furniture Plan

1 04/17/08 ADDENDUM MCM

Page 8: PROPOSED FIT-OUT & IMPROVEMENTS€¦ · contact: scott d'entremont gyp gypsum sab sound attenuating insulation mechanical / plumbing / fire protection engineer fax: (617) 350-0332

REF.

GFI

GFI

GFI

DN

GFI

GFI

LIGHTING LEGEND2 x 2 DIRECT / INDIRECT

6" RECESSED COMPACT FLUORESCENT

A

C

D

E

E1

TECH LIGHTING / MELODY 700MELO /44 (" LENGTH) / F (FROST) / S (SATIN NICKEL)

84" SUSPENDED SHOP LIGHT

48" SUSPENDED SHOP LIGHT

BPENDANT MOUNTED LOW VOLTAGE FIXTUREFORECAST / MINI PENDANT HOLDER F5312-36 SATIN NICKELw/ FORECAST / MARTA GLASS F5344-36

WALL SCONCE (SEE A 4.0 VIEW 7)FORECAST / F5410-68 DEEP BRONZE

1

FTECH LIGHTING / KABLE LITE SYSTEMw/ K-HELLO ARCHITECTURAL HEAD700KHELLO TYPE - 5 MR16 / CABLE SEPARATION 5.5"

G

CEILING LEGEND

ACT - 1ARMSTRONG - ULTIMA BEVELED TEGULAR - 1912W/ 9/16" SUPRAFINE EXPOSED TEE GRID

GWB SOFFIT

WOODSLAT SUSPENDED CEILINGARMSTRONG - WOODWORKS LINEAR /NORMAL 6" MODULE 6910 BAMBOO PATINA

ACT - 2ARMSTRONG - GEORGIAN SQUARE LAY-IN - 764W/ 15/16" PRELUDE GRID

ACDFGJ

5

6

A 4.0 5

A 4.1

58 SF

TOILET118

125 SF

AIRCRAFTSALES

105

106 SF

PRIVATEOFFICE

104

174 SF

PILOTLOUNGE

10259 SF

CORRIDOR103

96 SF

MECHANICALROOM

107

144 SF

PARTSROOM

108

404 SF

REPAIR /MAINTENACE

SHOP106

16' - 3"

2

3

7

5

4

8

A

A

A

C1

A

A2

E

E1

A

A2

A2 A

A

14

12

10' - 0"

2' - 1 1/2"

10' -

4"

5' -

0"9'

- 3"

A

4' - 7"

9' -

3 1/

2"

111 1 1 1

1

1

A

E

B

DOMESTICWATERSUPPLY

15' -

4"

20 SF

AIRCOMPRESSOR

CLOSET119

6

8' -

6"

39 SF

ELECTRICALCLOSET

120

2

10

6' - 0"

2' -

8 1/

2"

4' -

3 1/

2"11

' - 3

"

80 SF

CLASSROOM115

9' - 3"

13

3' - 8"

9

11

A 4.0

8

17

A 4.0

11

10

1

234 SF

LOBBY101

89 SF

RECEPTION113

40 SF

CORRIDOR114

168 SF

OFFICE112

459 SF

OFFICE(SHARED)

116

8 SF

J.C.109

52 SF

KITCHEN110

58 SF

TOILET111

A 4.0 9

A 4.1 1

A 4.0

4

C

C

A

A

A

A

B

E

BB

B

B

E

14' - 6" 18' - 6"

4' - 7"

8' -

8 1/

2"

30' - 6"

4' -

4"

25' -

0 1

/2"

CA

CA

2

C2

A1

A1

A

3

4

DD

A

A

E2

6' - 3"

A 4.06

7

8' -

6"

ICE

13' -

5"

11' -

7 1

/2"

WIRING FOR CUSTOMCASEWORK UNITOPENING AT 42" AFF

ICE MAKER & COFFEE MAKERWITH COLD WATERLINE

3

B

A

A

E

A

BOLLARDS

1

887

9

1' - 3 1/2"5' - 0"

1' -

0"

1' - 3 1/2" 4' - 10"

1' -

0"

3 1/

2"

1' -

6"

3' -

4"

8' - 0"

1' -

6"

RAMP

10

N

16

9' -

8" 6' -

11 1

/2"

18

20

21

19

1

1

1

1

1

ACDFGJ

5

6

AA

AA

AA

AAE

E

EE1E1 A A

A A

A

A

A

A

A A

A A

A A

A

A A

C

C

CCCC

D

13

A 5.0

6

A 5.0

B

B

8' - 6"AFF

8' - 6"AFF

8' - 6"AFF

8' - 6"AFF

8' - 6"AFF

8' - 6"AFF

8' - 6"AFF

8' - 6"AFF

8' - 6"AFF

8' - 6"AFF

8' - 6"AFF

12' - 0"AFF

12' - 0"AFF

NO CEILING8' - 0"AFF

VARIESAFF

C C

C

C

C

C

C C

C

C

C

C

2' -

0"

2' - 3" 14' - 0" 2' - 3"

2' -

0"

EQ EQ

EQ EQ

12

A 5.0C

E E

1

1

1

F F F F

F F F F

F F F

F

MCMUSA, LLC.181 WELLS AVE., NEWTON, MA 02459TEL.(617)969-1900 FAX(617)964-8297

All ideas, designs, arrangements, drawings andspecifications are owned by, and the propertyof this office and were created, evolved anddeveloped for use on, and in connection withthe specified project. None of such ideas,designs, arrangements or plans shall be usedby or disclosed to any person, firm orcorporation for any purpose whatsoeverwithout the written permission of this designoffice.

C 2008, MCMUSA, LLC.

All sub-trades and fabricators shall be responsible for field verifying all dimensions to ensureproper location and fit of all field construction and manufactured items called for or shown inthis drawing.

NOTE:

NO. DATE REVISIONS BY

DATE:

SCALE:

DRAWN:

CHECKED:

DRAWING NO:

PROJECT NO:

DATE:

DRAWING TITLE:

PROJECT:

THE APPROVAL OF THIS DOCUMENT CONSTITUTES ANACCEPTANCE OF ALL ITS CONTENT. DESIGN CHANGES AFTERTHIS APPROVAL REQUESTED BY THE CLIENT WILL BE SUBJECTTO ADDITIONAL CHARGES

APPROVED

APPROVED AS NOTED DATE:

BY:

492 Sutton St.North Andover, MA 01845

1/4" = 1'-0"

07120

A 2.104/25/08

LD

GC

04/25/08ISSUE FOR CONSTRUCTION

LAWRENCEMUNICIPALAIRPORT HANGARJET HANGAR 1

First FloorConstruction Plan& Reflected CeilingPlan

1/4" = 1'-0"1 Level 1 Construction Plan

1/4" = 1'-0"2 Level 1 Reflected Ceiling Plan

1 04/17/08 ADDENDUM MCM

Page 9: PROPOSED FIT-OUT & IMPROVEMENTS€¦ · contact: scott d'entremont gyp gypsum sab sound attenuating insulation mechanical / plumbing / fire protection engineer fax: (617) 350-0332

ACDFGJ

1

2

3

4

BH

F F F F

F F F F

EXISTING GIRTS & INSULATION TO REMAIN (TYP)

HIGH - BAY METAL HALIDE 1000W HID FIXTURES MOUNTEDTO UNDERSIDE OF METAL BUILDING TRUSSES (TYP)

F F F F

20' - 0" 20' - 0" 20' - 0"

20' - 0" 27' - 8" 20' - 0"ROLLUP HANGARDOORS (TYP.)

ACDFGJ

1

2

3

4

5

BH

AIRCOMPRESSOR

CLOSET

9153 SF

HANGAR117

NEW CONCRETE SLABEPOXY FLOOR FINISH

W/ RADIANT HEAT IN FLOOR

NEW SILLCOCK

7

14

CA

CA

4' - 7" A 4.1

3

E

INFILL DOOR OPENINGINSTALL NEW STEEL

DOOR & FRAME

BOLLARDS

INFILL DOOR OPENINGINSTALL NEW STEELDOOR & FRAME

CA

CA

15

16

6

8' -

6"

39 SF

ELECTRICALCLOSET

120

D

11

17COMPRESSORBY TENANTS

CA

RAMP

5' - 0"

6' -

0"5'

- 0"

HANDRAILS

16

MCMUSA, LLC.181 WELLS AVE., NEWTON, MA 02459TEL.(617)969-1900 FAX(617)964-8297

All ideas, designs, arrangements, drawings andspecifications are owned by, and the propertyof this office and were created, evolved anddeveloped for use on, and in connection withthe specified project. None of such ideas,designs, arrangements or plans shall be usedby or disclosed to any person, firm orcorporation for any purpose whatsoeverwithout the written permission of this designoffice.

C 2007, MCMUSA, LLC.

All sub-trades and fabricators shall be responsible for field verifying all dimensions to ensureproper location and fit of all field construction and manufactured items called for or shown inthis drawing.

NOTE:

NO. DATE REVISIONS BY

DATE:

SCALE:

DRAWN:

CHECKED:

DRAWING NO:

PROJECT NO:

DATE:

DRAWING TITLE:

PROJECT:

THE APPROVAL OF THIS DOCUMENT CONSTITUTES ANACCEPTANCE OF ALL ITS CONTENT. DESIGN CHANGES AFTERTHIS APPROVAL REQUESTED BY THE CLIENT WILL BE SUBJECTTO ADDITIONAL CHARGES

APPROVED

APPROVED AS NOTED DATE:

BY:

492 Sutton St.North Andover, MA 01845

1/8" = 1'-0"

07120

A 2.204/25/08

LD

GC

04/25/08ISSUE FOR CONSTRUCTION

LAWRENCEMUNICIPALAIRPORT HANGARJET HANGAR 1

Airplane HangarConstruction Plan& Reflected Ceiling

Plan

1/8" = 1'-0"2 Hangar Reflected Ceiling Plan 1/8" = 1'-0"1 Hangar Construction Plan

Page 10: PROPOSED FIT-OUT & IMPROVEMENTS€¦ · contact: scott d'entremont gyp gypsum sab sound attenuating insulation mechanical / plumbing / fire protection engineer fax: (617) 350-0332

Level 10' - 6"

Roof Plan26' - 1 1/2"

A C D F G JB H

Front ElevationGrade4' - 0"

ADD HEADER, EXTENDCLADDING TO MATCH EXISTING

1' -

0"

26' - 0"

RETRACTABLE DOOR COLUMNS

ROLL UP HANGARDOORS (3 SECTIONS)

Hangar Level0' - 0"

Level 10' - 6"

Roof Plan26' - 1 1/2"

123456

Front ElevationGrade4' - 0"

ADD GIRT, INFILLOPENING, EXTENDCLADDING &INSULATION TOMATCH EXISTING

ADD METALSTUD FRAMINGFOR DOORJAMB/HEADER,STEEL DOOR

NEW WINDOW, TYP

Hangar Level0' - 0"

1 1

ALUMINUM FRAMEDFIXED WINDOWSIZED TO FIT EXISTINGOPENINGGLASS COMPANY TOPROVIDE SHOPDRAWINGS FORGENERAL CONTRACTOR'SAPPROVAL

5 5 5

6

EXTEND CONCRETEFOUNDATION WALLTO MATCH EXISTING

2 2

MCMUSA, LLC.181 WELLS AVE., NEWTON, MA 02459TEL.(617)969-1900 FAX(617)964-8297

All ideas, designs, arrangements, drawings andspecifications are owned by, and the propertyof this office and were created, evolved anddeveloped for use on, and in connection withthe specified project. None of such ideas,designs, arrangements or plans shall be usedby or disclosed to any person, firm orcorporation for any purpose whatsoeverwithout the written permission of this designoffice.

C 2008, MCMUSA, LLC.

All sub-trades and fabricators shall be responsible for field verifying all dimensions to ensureproper location and fit of all field construction and manufactured items called for or shown inthis drawing.

NOTE:

NO. DATE REVISIONS BY

DATE:

SCALE:

DRAWN:

CHECKED:

DRAWING NO:

PROJECT NO:

DATE:

DRAWING TITLE:

PROJECT:

THE APPROVAL OF THIS DOCUMENT CONSTITUTES ANACCEPTANCE OF ALL ITS CONTENT. DESIGN CHANGES AFTERTHIS APPROVAL REQUESTED BY THE CLIENT WILL BE SUBJECTTO ADDITIONAL CHARGES

APPROVED

APPROVED AS NOTED DATE:

BY:

492 Sutton St.North Andover, MA 01845

1/4" = 1'-0"

07120

A 3.004/25/08

LD

GC

04/25/08ISSUE FOR CONSTRUCTION

LAWRENCEMUNICIPALAIRPORT HANGARJET HANGAR 1

Exterior ElevationsNorth & East

1/4" = 1'-0"1 Exterior Elevation North

1/4" = 1'-0"2 Exterior Elevation East

Page 11: PROPOSED FIT-OUT & IMPROVEMENTS€¦ · contact: scott d'entremont gyp gypsum sab sound attenuating insulation mechanical / plumbing / fire protection engineer fax: (617) 350-0332

Level 10' - 6"

Roof Plan26' - 1 1/2"

ACDFGJ BH

Front ElevationGrade4' - 0"

3' - 9 1/2" 3' - 9 1/2" 3' - 9 1/2" 3' - 9 1/2" 3' - 9 1/2"

2' -

6"5'

- 6"

12' - 2" 5' - 8" 3' - 7" 5' - 8" 4' - 3" 5' - 8" 5' - 8" 4' - 3" 5' - 8" 3' - 7" 5' - 8" 12' - 2"

111 1 1 1 4' -

0"

4' -

0"

CANVAS AWNING TBD

2 2 2 2 2 2 22

RECESSED KNOX BOXMANUFACTURE TBD

10

A 5.0

1

Level 10' - 6"

Roof Plan26' - 1 1/2"

1 2 3 4 5 6

Front ElevationGrade4' - 0"

INFILL OPENING,EXTEND

CLADDING TOMATCH

EXISTING, ADDINSULATION

ADD METALSTUD FRAMING

FOR DOORJAMB/HEADER,

STEEL DOOR

Hangar Level0' - 0"

NEW RTU

55522

MCMUSA, LLC.181 WELLS AVE., NEWTON, MA 02459TEL.(617)969-1900 FAX(617)964-8297

All ideas, designs, arrangements, drawings andspecifications are owned by, and the propertyof this office and were created, evolved anddeveloped for use on, and in connection withthe specified project. None of such ideas,designs, arrangements or plans shall be usedby or disclosed to any person, firm orcorporation for any purpose whatsoeverwithout the written permission of this designoffice.

C 2008, MCMUSA, LLC.

All sub-trades and fabricators shall be responsible for field verifying all dimensions to ensureproper location and fit of all field construction and manufactured items called for or shown inthis drawing.

NOTE:

NO. DATE REVISIONS BY

DATE:

SCALE:

DRAWN:

CHECKED:

DRAWING NO:

PROJECT NO:

DATE:

DRAWING TITLE:

PROJECT:

THE APPROVAL OF THIS DOCUMENT CONSTITUTES ANACCEPTANCE OF ALL ITS CONTENT. DESIGN CHANGES AFTERTHIS APPROVAL REQUESTED BY THE CLIENT WILL BE SUBJECTTO ADDITIONAL CHARGES

APPROVED

APPROVED AS NOTED DATE:

BY:

492 Sutton St.North Andover, MA 01845

1/4" = 1'-0"

07120

A 3.104/25/08

LD

GC

04/25/08ISSUE FOR CONSTRUCTION

LAWRENCEMUNICIPALAIRPORT HANGARJET HANGAR 1

Exterior ElevationsSouth & West

1/4" = 1'-0"1 Exterior Elevation South

1/4" = 1'-0"2 Exterior Elevation West

1 04/17/08 ADDENDUM MCM

Page 12: PROPOSED FIT-OUT & IMPROVEMENTS€¦ · contact: scott d'entremont gyp gypsum sab sound attenuating insulation mechanical / plumbing / fire protection engineer fax: (617) 350-0332

5' -

0"

PT - 2

OPEN

PT - 2

CT - 2

WD BASE / PT - 1

MANTLE PREMIER "SOMERSET" PTD

DIRECT VENT GAS FIREPLACEVERMONT CASTINGS "CHATEAU" DVT38IN

4' -

0"

PT - 1PT - 1

PT - 1

TV BYTENANT

OPEN

GWB SOFFIT

SUSPENDEDWOOD SLATCEILING

R 1

0' -

6"

8' -

6"

R 1

3' -

0"

11' -

5 1

/2"

WD BASE / PT - 1

A 5.011

1

4' -

0"

PT - 2

PT - 2 PT - 2

LAMINATED SAFETYGLASS PARTITION

STOREFRONT (BEYOND)

3' -

6"6'

- 10

"

WD BASE / PT - 1

WD CAP / PT -

PT - 2

E1A 5.0

TYP

G1A 5.0

TYP

B1A 5.0

TYP

4' -

6"

2' -

6"

5' -

6"

2' - 8" 2' - 8" 2' - 8" 1' - 6"1' - 6" 2' - 8" 2' - 8"3' - 0"

9' - 6"6' - 10"

3' -

6"2' -

6"

PT - 6 PL - 3 (TYP)

PL - 3 (TYP)

VB - 1

FIBERGLASS UTILITY SINK

PT - 6

3' -

0"

1' - 6"

6" 3' - 0"

5' -

9"

PT - 1CT - 5 BULLNOSE

CT - 4 FIELD

CT - 6 BASE

MOISTER RESISTANT GWB

2' -

10"

3' -

0"4'

- 0"

3' -

0"

PT - 5

PL - 2

3' - 0"

VB - 1

G1A 5.0

PT - 1PL - 2

OPEN

3' -

0"

3' -

0"3'

- 6"

VB - 1

END PANEL

3' -

0"2'

- 6"

2' -

0"

ICE MAKERBY TENANT

COFFEE MAKER

H1A 5.0

HA 5.0

G2A 5.0

PT - 4PT - 1

PL - 1 (TYP)

SDS - 1

PT - 4

REFRIGERATORBY TENANT

VENEER BASE TOMATCH CABINETS

WD BASE / PT - 1ENDPANEL

G1A 5.0

PT - 5

PL - 2

PT - 5

2' -

6"

VB - 1

2' -

0"

PL - 1F

A 5.0

3' -

4"

2' -

10"

1' - 1 1/2" 1' - 1 1/2"

EQ EQ

MIRROR

5' -

9"

PT - 1

CT - 5 BULLNOSE

CT - 4 FIELD

CT - 6 BASE

SDS - 2

WALL SCONCE

SOLIDSURFACECOUNTER& APRON

14

A 5.0

1

OPEN

3' -

0"3' - 0"

7' -

0"

PT -1

PT -1

PT -1

WD BASE / PT - 1

8' -

6"

GWB SOFFIT

SUSPENDEDWOODSLATCEILING

R 10' - 6"

R 13' - 0"

11' -

5 1

/2"

MCMUSA, LLC.181 WELLS AVE., NEWTON, MA 02459TEL.(617)969-1900 FAX(617)964-8297

All ideas, designs, arrangements, drawings andspecifications are owned by, and the propertyof this office and were created, evolved anddeveloped for use on, and in connection withthe specified project. None of such ideas,designs, arrangements or plans shall be usedby or disclosed to any person, firm orcorporation for any purpose whatsoeverwithout the written permission of this designoffice.

C 2008, MCMUSA, LLC.

All sub-trades and fabricators shall be responsible for field verifying all dimensions to ensureproper location and fit of all field construction and manufactured items called for or shown inthis drawing.

NOTE:

NO. DATE REVISIONS BY

DATE:

SCALE:

DRAWN:

CHECKED:

DRAWING NO:

PROJECT NO:

DATE:

DRAWING TITLE:

PROJECT:

THE APPROVAL OF THIS DOCUMENT CONSTITUTES ANACCEPTANCE OF ALL ITS CONTENT. DESIGN CHANGES AFTERTHIS APPROVAL REQUESTED BY THE CLIENT WILL BE SUBJECTTO ADDITIONAL CHARGES

APPROVED

APPROVED AS NOTED DATE:

BY:

492 Sutton St.North Andover, MA 01845

3/8" = 1'-0"

07120

A 4.004/25/08

LD

GC

04/25/08ISSUE FOR CONSTRUCTION

LAWRENCEMUNICIPALAIRPORT HANGARJET HANGAR 1

Interior Elevations

3/8" = 1'-0"2 Elevation at Pilot's Lounge 3/8" = 1'-0"3 Elevation at Lobby

3/8" = 1'-0"4 Elevation at Lobby - d 3/8" = 1'-0"5 Elevation at Repair / Maintenance

3/8" = 1'-0"6 Elevation at Toilet 111 - a

3/8" = 1'-0"10 Elevation at Classroom - a 3/8" = 1'-0"11 Elevation at Classroom - b

3/8" = 1'-0"8 Elevation at Kitchen 3/8" = 1'-0"9 Elevation at Office

3/8" = 1'-0"7 Elevation at Toilet 111 - b

3/8" = 1'-0"1 Elevation at Reception

1 04/17/08 ADDENDUM MCM

Page 13: PROPOSED FIT-OUT & IMPROVEMENTS€¦ · contact: scott d'entremont gyp gypsum sab sound attenuating insulation mechanical / plumbing / fire protection engineer fax: (617) 350-0332

2' -

10"

3' -

0"

1' - 6"

3' - 0" 6"

1' - 8 1/2"

3' -

4"

MIRRORPT - 3

VB - 1

Level 10' - 6"

Roof Plan26' - 1 1/2"

A C D F G J

Front ElevationGrade4' - 0"8'

- 0"

ROLL UP DOOR

9' -

0"

9' -

0"

4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 3' - 10 1/2" 3' - 10 1/2" 3' - 10 1/2"

Hangar Level0' - 0"

PT - 2

PT - 2

PT - 2PT - 2

7' -

0"

45.00° 45.00°

OPEN TO ABOVE

OPAQUE SPANDREL GLASSCOLOR SELECTION TO BECOORDINATED WITH MCMDESIGN

LAMINATED SAFETY GLASS50% LIGHT TRANSMISSION

VB - 1

CORNER GUARDS

AD

1

1' -

0"

WATER CURTAIN SOFFIT

3' -

6"

13' - 5" 11' - 7 1/2"

PT - 4PT - 7

WIRING FOR CUSTOMCASEWORK UNITOPENING AT 42" AFF

PT - 7PT - 4 PT - 4

MCMUSA, LLC.181 WELLS AVE., NEWTON, MA 02459TEL.(617)969-1900 FAX(617)964-8297

All ideas, designs, arrangements, drawings andspecifications are owned by, and the propertyof this office and were created, evolved anddeveloped for use on, and in connection withthe specified project. None of such ideas,designs, arrangements or plans shall be usedby or disclosed to any person, firm orcorporation for any purpose whatsoeverwithout the written permission of this designoffice.

C 2008, MCMUSA, LLC.

All sub-trades and fabricators shall be responsible for field verifying all dimensions to ensureproper location and fit of all field construction and manufactured items called for or shown inthis drawing.

NOTE:

NO. DATE REVISIONS BY

DATE:

SCALE:

DRAWN:

CHECKED:

DRAWING NO:

PROJECT NO:

DATE:

DRAWING TITLE:

PROJECT:

THE APPROVAL OF THIS DOCUMENT CONSTITUTES ANACCEPTANCE OF ALL ITS CONTENT. DESIGN CHANGES AFTERTHIS APPROVAL REQUESTED BY THE CLIENT WILL BE SUBJECTTO ADDITIONAL CHARGES

APPROVED

APPROVED AS NOTED DATE:

BY:

492 Sutton St.North Andover, MA 01845

As indicated

07120

A 4.104/25/08

LD

GC

04/25/08ISSUE FOR CONSTRUCTION

LAWRENCEMUNICIPALAIRPORT HANGARJET HANGAR 1

Interior Elevations

3/8" = 1'-0"2 Elevation at Toilet 118

1/4" = 1'-0"3 North Interior

3/8" = 1'-0"1 Elevation at Office (Shared)

1 04/17/08 ADDENDUM MCM

Page 14: PROPOSED FIT-OUT & IMPROVEMENTS€¦ · contact: scott d'entremont gyp gypsum sab sound attenuating insulation mechanical / plumbing / fire protection engineer fax: (617) 350-0332

RC2 CLIP

4 1/2" LINEAR PLANK MODULE

LINEAR CARRIER

HA 5.0

UPPER & LOWER CABINETS W/ SINKSCALE: 1" = 1'-0"

2' - 0"

1' - 1"

1" 3"

2' -

0"

7' -

6"

RESILIENT BASE.

CEILING(HT. VAR.)

ALL VISIBLE HORZ.SURFACES TO BE PL. LAM.UNLESS OTHERWISENOTED

ALL VISIBLE VERT. SUR.T.B.COV'D W/ PL.LAM.

ALL CORE MAT. T.B. 3/4"P.B.ALL CAB TO REC. WIREPULLS AND LOCKS.

HINGED DOORS

PILASTER STRIPS& SHELF RESTS.

3/4" ADJ . PART. BDSHELF, MELAMINE COV'D

UNDER CAB.TASK LIGHT

END SPLASHES ATALL CABINETS ANDAT ALL WALLS

FIXED PANEL

CAM LOCK

H1A 5.0

LAVATORY

UPPER CABINETOMIT LOWER CABINETS W/ SINK

ALL VISIBLE SURFACESTO BE PL. LAM. COV'D.

ALL CORE MAT TO BE3/4" PART. BD.

SUPPORT BRACKET

UNDERSHELFLIGHT

2' - 0"

RESILIENT BASE

2' -

6"2'

- 6"

6"

1' - 0"

2 3/

4"

SCALE: 1" = 1'-0"LEDGE & SHELF

LEDGEOMIT SHELF

G

A 5.0

G1A 5.0

5' -

0"

LEDGEOMIT SHELFUSE SOLID SURFACE (NO PL)

G2A 5.0

CEILING(HT. VAR.)

ALL VISIBLE HORZ.SURFACES TO BE PL.LAM.

ALL VISIBLE VERT. SUR.T.B.COV'D W/ PL.

ALL CORE MAT. T.B.3/4" P.B.ALL CAB TO REC. WIREPULLS AND LOCKS.

HINGED DOORS

PILASTER STRIPS& SHELF RESTS.

3/4" ADJ . PART. BDSHELF, MELAMINE COV'D

UNDERCAB.TASKLIGHT

B1A 5.0

30" UPPER WALL CABINETWITHOUT LOCKS

BA 5.0

30" UPPER WALL CABINETSCALE: 1" = 1'-0"

1" 3"

2' -

6"

1' - 1"

UNDERCAB.TASKLIGHT

E1A 5.0

42" UPPER WALL CABINETWITHOUT LOCKS

EA 5.0

42" UPPER WALL CABINETSCALE: 1" = 1'-0"

CEILING(HT. VAR.)

ALL VISIBLE HORZ.SURFACES TO BE PL.LAM.

ALL VISIBLE VERT. SUR.T.B.COV'D W/ PL.

ALL CORE MAT. T.B.3/4" P.B.ALL CAB TO REC. WIREPULLS AND LOCKS.

HINGED DOORS

PILASTER STRIPS& SHELF RESTS.

3/4" ADJ . PART. BDSHELF, MELAMINE COV'D

1' - 1"

3' -

6"

3"1"

ACOUSTICAL CEILING

GWB SOFFIT

SCALE: 1" = 1'-0"ADJUSTABLE SHELVESF

A 4.0

1' - 0"

ADJUSTABLEWD SHELF

BRACKETS SETIN KV HVY DUTYDBL SLOT STANDARDS

ALL VISIBLE SURFACEST.B. COV'D W/ P. LAM. PL-1

SEE ELEVATIONSFOR QUANTITY OFSHELVES

TASK LIGHT UNDERLOWEST SHELF

GWB

GWB

WINDOW

1

WINDOWMULLION

AWOOD

SLATCEILING

GWB SOFFIT

SUSPENDEDWOOD SLATCEILING

1

GWB

1

SDS - 2

ADA SS SINK -UNDERMOUNT

SOLIDBLOCKING

APRON

6"

1

MCMUSA, LLC.181 WELLS AVE., NEWTON, MA 02459TEL.(617)969-1900 FAX(617)964-8297

All ideas, designs, arrangements, drawings andspecifications are owned by, and the propertyof this office and were created, evolved anddeveloped for use on, and in connection withthe specified project. None of such ideas,designs, arrangements or plans shall be usedby or disclosed to any person, firm orcorporation for any purpose whatsoeverwithout the written permission of this designoffice.

C 2008, MCMUSA, LLC.

All sub-trades and fabricators shall be responsible for field verifying all dimensions to ensureproper location and fit of all field construction and manufactured items called for or shown inthis drawing.

NOTE:

NO. DATE REVISIONS BY

DATE:

SCALE:

DRAWN:

CHECKED:

DRAWING NO:

PROJECT NO:

DATE:

DRAWING TITLE:

PROJECT:

THE APPROVAL OF THIS DOCUMENT CONSTITUTES ANACCEPTANCE OF ALL ITS CONTENT. DESIGN CHANGES AFTERTHIS APPROVAL REQUESTED BY THE CLIENT WILL BE SUBJECTTO ADDITIONAL CHARGES

APPROVED

APPROVED AS NOTED DATE:

BY:

492 Sutton St.North Andover, MA 01845

As indicated

07120

A 5.004/25/08

LD

GC

04/25/08ISSUE FOR CONSTRUCTION

LAWRENCEMUNICIPALAIRPORT HANGARJET HANGAR 1

InteriorConstructionDetails

1" = 1'-0"1 Upper & Lower Cabinet W/ Sink Detail 1" = 1'-0"4 Ledge & Shelf Detail

1" = 1'-0"2 30" Upper Cabinet Detail 1" = 1'-0"3 42" Upper Cabinet Detail

1" = 1'-0"6 Office (Shared) Soffit Detail 1" = 1'-0"7 Wood Ceiling DetailNOT TO SCALE 1" = 1'-0"8 Fireplace Detail Plan View

1" = 1'-0"9 Fireplace Detail SectionNOT TO SCALE NOT TO SCALE

1" = 1'-0"5 Adjustable Shelves

1 04/17/08 ADDENDUM MCM

1" = 1'-0"10 Window Detail 1" = 1'-0"11 Wood Slat Ceiling w/ Window Detail

1

1" = 1'-0"12 Wood Slat Ceiling w/ GWB Soffit Detail 1 1/2" = 1'-0"13 Water Curtain Soffit Detail

3/4" = 1'-0"14 Solid Surface Detail