PROJECT RENDERING DRAWING INDEX

1
PROJECT TEAM: ARCHITECT: CLIENT: Architecture Planning Interiors Preservation Urban Design www.arkinetics.com architects + urbanists STRUCTURAL ENGINEER: 2012 West 25th St., Suite 200 Cleveland, OH 44113 P: 216. 227. 8505 F: 216. 227. 8570 MECHANICAL / ELECTRICAL ENGINEER: 2012 West 25th St., Suite 200 Cleveland, OH 44113 P: 216. 227. 8505 F: 216. 227. 8570 MECHANICAL / ELECTRICAL ENGINEER: 2012 West 25th St., Suite 200 Cleveland, OH 44113 P: 216. 227. 8505 F: 216. 227. 8570 ANCHOR BOLT AIR CONDITIONING ACOUSTIC(AL) ACOUSTICAL CEILING TILE ADJACENT ABOVE FINISH FLOOR ALTERNATE ALUMINUM ANODIZED APPROXIMATE ARCHITECT(URAL) AUTOMATIC BOARD BETWEEN BUILDING BLOCK(ING) BULKHEAD BEAM BOTTOM BRIDGING BEARING BRICK BASEMENT BUILT-UP ROOFING CENTER TO CENTER CABINET CADMIUM CATCH BASIN CEMENT CENTER LINE CUBIC FEET PER MINUTE CORNER GUARD CAST IRON CONTROL JOINT CEILING CLOSET CLEAR CONTRACT LIMIT LINE COUNTER CERAMIC MOSAIC TILE CONCRETE MASONRY UNIT CASED OPENING/CLEAN OUT AB A/C ACOUS ACT ADJ AFF ALT ALUM ANOD APPROX ARCH AUTO BD BETW BLDG BLK BLKHD BM BOT BRDG BRG BRK BSMT BUR C/C CAB'T CAD CB CEM CL or CFM CG CI CJ CLG CL CLR CLL CNTR CMT CMU CO COLUMN CONCRETE CONNECTION CONSTRUCTION CONTINUOUS COORDINATE CORRIDOR CARPET CONCRETE SEALER COURSE CERAMIC TILE CERAMIC TILE - PORCELAIN CENTER DEPTH DOUBLE DEGREES DEMOLITION DRINKING FOUNTAIN DIAMETER DIMENSION DISPENSER DOWN DOOR DOWN SPOUT DETAIL DRAWING DRAWER DRYWALL EXPOSED STEEL EXISTING TO REMAIN EXISTING FIRE ALARM FACE BRICK FAN COIL UNIT FACE TO FACE FLOOR DRAIN FOUNDATION FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FIRE HOSE CABINET FINISH COL CONC CONN CONST CONT COORD/ CORR CPT CS CSLR CT CTP CTR D DBL DEG DEMO DF DIA DIM DISP DN DR DS DET DWG DWR DW ES ETR EXIST FA FB FCU F/F FD FDN FE FEC FHC FIN FLOOR FLUORESCENT FACE OF MASONRY FIRE RESISTANT FIBERGLASS REINFORCED PANELS FIRE-RETARDANT TREATED FIRE-RETARDANT TREATED WOOD FEET FOOTING FURRING FIRE VALVE CABINET FABRIC WALLCOVERING GAUGE GALVANIZED GENERAL CONTRACTOR GLASS GRADE GYPSUM BOARD GYPSUM WALL BOARD HIGH HOSE BIBB HOLLOW CORE HARDBOARD HANDICAPPED HARDWARE HARDWOOD HOLLOW METAL HORIZONTAL HIGH PERFORMANCE COATING HIGH PRESSURE DECORATIVE LAMINATE HOUR HEIGHT HEATING HEATER HEATING, VENTILATION AIR CONDITIONING HOT WATER HOT WATER HEATER FLR FLUOR FM FR FRP FRT FRTWD FT FTG FURR FVC FWC GA GALV GC GL GR GYP BD GWB H HB HC HDBD HDCPD HDWR HDWD HM HORIZ HPC HPDL HR HT HTG HTR HVAC HW HWH INSIDE DIAMETER INCH INCLUDE (INCLUSIVE) INSULATION INTERIOR JANITOR JOIST KNOCK DOWN KNOCK OUT LENGTH (LONG) LAMINATE(D) LAVATORY POUND LINEAR FEET (FOOT) LIMITED LIGHT LIGHTING LOUVER MARBLE MASONRY MATERIAL MAXIMUM MECHANICAL MEMBRANE MANUFACTURER MANHOLE MINIMUM MISCELLANEOUS MASONRY OPENING MOUNTED METAL MULLION NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE ID IN INCL INSUL INT JAN JST KD KO L LAM LAV LB LF LIM LT LTG LVR MARB MAS MAT MAX MECH MEMB MFR MH MIN MISC MO MTD MTL MULL N/A NIC NO NOM NTS OVERALL ON CENTER ON CENTER ABOVE FINISH FLOOR OUTSIDE DIAMETER OVERHEAD DOOR OPPOSITE HAND OVERFLOW ROOF DRAIN OUT TO OUT OPENING OPPOSITE OPTIONAL PAVER TILE PARTICLE BOARD PRECAST CONCRETE POUNDS PER CUBIC FOOT PREFACED CONCRETE MASONRY PERIMETER PEG BOARD PLATE PLASTIC PLASTIC LAMINATE PLUMBING PREMOULDED PANEL PAINT PLYWOOD POLISHED PAIR PREFINISHED PREFABRICATED PROJECTION PRE-STRESS CONCRETE POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH POINT/PAVER TILE PAINTED PARTITION PRESSURE TREATED WOOD POLYVINYLCHLORIDE PAVEMENT OA OC OCAFF OD OHDR OPH OVRD O/O OP'G OPP OPT PT PBD PC PCF PCM PERIM PG BD PL PLAS PLAM PLBG PMLD PNL PNT PLYWD POL PR PREFIN PREFAB PROJ PSC PSF PSI PT PTD PTN PTWD PVC PVMT QUARRY TILE QUANTITY RISER RETURN AIR RADIUS RETURN AIR GRILLE ROOF DRAIN RECEPTACLE REFRIGERATOR REGISTER REINFORCEMENT (REINFORCING) REQUIRED RESILIENT RETURN REVISED (REVISION) RESINOUS FLOORING ROOM ROUGH OPENING REVERSE SOLID CORE SCHEDULE SMOKE DETECTOR SADDLE SECTION SHEET SIMILAR SLATE STAND PIPE SPECIFICATIONS SPEAKER SPRINKLER SINGLE PLY ROOFING SQUARE SQUARE INCH SQUARE YARD STAINLESS STEEL/ SLOP SINK STANDARD STEEL STORAGE STRUCTURE(AL) QT QTY R RA RAD RAG RD REC REF REG REINF REQ'D RES RET REV RF RM RO RVS SC SCHED SD SDL SECT SHT SIM SLT SP SPEC SPKR SPKLR SPR SQ SQ IN SY SS STD STL STOR STRUC SUSPENDED SHEET VINYL SEAMLESS VINYL - NON SLIP SEAMLESS VINYL SHEET SYSTEMS THREAD TONGUE AND GROOVE TONGUE AND GROOVE TRENCH DRAIN TELEPHONE TEMPORARY TEMPERED TERRAZZO TEXTURE THICK THRESHOLD TOP OF CONCRETE (TOP OF CURB) TOP OF STEEL TOP OF DECK TOP OF MASONRY TOP OF JOIST TOP OF PARAPET TOP OF WALL TYPICAL UNDERCUT UNDERGROUND UNFINISHED UNLIMITED UNLESS NOTED OTHERWISE URINAL VERTICAL VESTIBULE VINYL COVE VINYL COMPOSITE TILE VERIFY IN FIELD VINYL STRAIGHT VINYL WALLCOVERING SUSP SV SVNS SVS SYS T T/G T&G TD TEL TEMP TEMP'D TER TEX THK THLD TOC TOS TOD TOM TOJ TOP TOW TYP UC UG UNFIN UNLIM UNO UR VERT VEST VC VCT VIF VS VWC WIDTH WITH WITHOUT WALL TO WALL WATER CLOSET WALL CARPET WOOD WATER HEATER MOISTURE AND MOLD RESISTANT GYPSUM WALL BOARD WINDOW WIRE GLASS WEIGHT WELDED WIRE FABRIC YARD W W/ W/O W/W WC WCAR WD WH WGWB WIN WG WT WWF YD ABBREVIATION LEGEND: SYMBOLS A8888 8 8 8 8 8 8 8 8 X X 88 A8888 INTERIOR AND EXTERIOR ELEVATION REFERENCE: DRAWING NUMBER(S) SHEET NUMBER STRUCTURAL GRID: NEW GRID REFERENCE GRID BUILDING, WALL, AND DETAIL SECTION REFERENCE: DRAWING NUMBER SHEET NUMBER 88 A8888 ENLARGED PLAN OR DETAIL CALLOUT REFERENCE: DRAWING NUMBER SHEET NUMBER 888A 2-D-101 150 SF ROOM NAME FUNCTIONS DOOR IDENTIFICATION: NEW 888A EXISTING DOOR LETTER DOOR NUMBER CORRESPONDS TO ROOM NUMBER ROOM IDENTIFICATION: ROOM NAME ROOM NUMBER ROOM AREA (WHEN INDICATED) CEILING IDENTIFICATION: WWW-88 88'-8" CEILING TYPE CEILING HEIGHT ABOVE FINISH FLOOR WALL IDENTIFICATION: WW88 A WALL TYPE. SEE CORRESPONDING SCHEDULES AND/OR DETAILS KEYNOTE IDENTIFICATION: KEYNOTE NUMBER; SEE CORRESPONDING NOTE ON KEYNOTE LEGEND ELSEWHERE ON SAME SHEET ? FINISH FLOOR LEVEL 101.00 FINISH FLOOR LEVEL 101.00 LEVEL LINE, CONTROL POINT, OR DATUM: NEW LEVEL EXISTING LEVEL W WINDOW / STOREFRONT GLAZING IDENTIFICATION: WINDOW OR STOREFRONT GLAZING TYPE. SEE CORRESPONDING SCHEDULES AND/OR DETAILS. 1. ALL PRODUCT INSTALLATION SHALL BE PERFORMED ACCORDING TO MANUFACTURER'S WRITTEN SPECIFICATIONS AND INDUSTRY STANDARDS. 2. NO SUBSTITUTIONS SHALL BE MADE WITHOUT THE WRITTEN APPROVAL OF THE OWNER, CONTRACTOR AND ARCHITECT. 3. ALL CONTRACTORS SHALL BE LICENSED AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. 4. ALL CONTRACTORS SHALL INSPECT THE PROJECT AS RELATED TO THEIR SCOPES OF WORK AND BECOME FAMILIAR WITH ALL EXISTING CONDITIONS AS REQUIRED FOR THE PROPER EXECUTION OF THEIR WORK. 5. ANY CONFLICTS OR INTERFERENCES OF THE PROPOSED WORK WITH THE EXISTING CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE GENERAL CONTRACTOR FOR RESOLUTION WITH THE OWNER AND ARCHITECT. 6. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING DISRUPTIONS TO THE UTILITIES AND SHALL INFORM THE OWNER OF SUCH ACTIVITIES. 7. "FURNISH" MEANS TO SUPPLY TO THE JOBSITE. "INSTALL" MEANS TO PLACE THE ITEM IN THE SPECIFIED LOCATION AND MAKE IT FUNCTIONAL. "PROVIDE" MEANS TO FURNISH & INSTALL. 8. THE JOBSITE SHALL BE KEPT FREE OF DEBRIS AND MADE BROOM-CLEAN EACH DAY. 9. MOCK-UPS AND SAMPLES SHALL BE PROVIDED TO THE OWNER FOR ALL NEW FINISHES. MOCK-UPS MAY BE PART OF THE FINAL WORK AND APPROVED BY THE OWNER AND ARCHITECT, PROVIDED OTHER REQUIREMENTS ARE MET. 10. ALL EXISTING CONDITIONS AND NEW WORK ARE "TYPICAL" UNLESS NOTED OTHERWISE. 11. THE GENERAL CONTRACTOR AND SUB CONTRACTORS SHALL FAMILIARIZE THEMSELVES WITH ALL EXISTING CONDITIONS PRIOR TO SUBMITTING THEIR BID, NOTIFY THE OWNER IMMEDIATELY OF ANY DISCREPANCIES. 12. ALL MATERIALS FURNISHED ON THE JOB SITE SHALL BE NEW AND STORED IN SUCH A MANNER AS TO PROTECT THEM FROM THE ELEMENTS. 13. DO NOT SCALE DRAWINGS, DIMENSIONS AND/OR EXISTING CONDITIONS GOVERN, NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. 14. SUPPORT WIRES FOR CEILINGS, SOFFITS, ETC. SHALL NOT BE CONNECTED TO ANY MECHANICAL, ELECTRICAL, PLUMBING OR FIRE PROTECTION PIPING, ETC. 15. DURING CONSTRUCTION THE CONTRACTOR SHALL COORDINATE ALL ACTIVITIES WITH THE OWNER OR OWNER'S REPRESENTATIVE. 16. ENTRIES IN THE REVISION COLUMN OF ANY SCHEDULED ITEM INDICATE THAT THE ITEM HAS CHANGED IN THAT REVISION SEQUENCE. ITEMS REMOVED FROM THE PROJECT WILL NOT APPEAR IN SCHEDULES. PROJECT GENERAL NOTES LOCATION AND SITE DATA NORTH PROJECT LOCATION DANIEL J. BARNEY 0413550 T C E T I H C R A D E R E T S I G E R O I H O F O E T A T S DANIEL J. BARNEY , LICENSE#: 0413550 EXPIRATION DATE: 12/31/2021 architects + urbanists Architecture • Planning • Interiors • Preservation • Urban Design www.arkinetics.com Cleveland Office 3723 Pearl Road Cleveland, OH 44109 DEALER CODE: SHEET #: DATE: PROJECT #: DRAWING TITLE: arkinetics © 2021 DRAWN BY: CHECKED BY: Arkinetics, Inc. and their Consultants shall be deemed the authors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. The Instruments of Service shall not be used for future additions or alterations to this Project or for other projects, without the prior written agreement of Arkinetics, Inc. Any unauthorized use of the Instruments of Service shall be at the Owner's sole risk and without liability to Arkinetics, Inc. and their Consultants ISSUE: MARK: P: 216.749.7800 F: 216.749.1300 OH011 C:\Revit\Marhofer Hyunda-Cuyahoga Falls_21015.02_rbenton6XF9T.rvt 10/7/2021 10:24:31 PM RON MARHOFER HYUNDAI Marhofer Hyundai Cuyahoga Falls 1260 Main Street, Cuyahoga Falls, Ohio COVER SHEET G0.01 21015.02 BRP DB RON MARHOFER HYUNDAI Marhofer Hyundai Cuyahoga Falls 1260 Main Street, Cuyahoga Falls, Ohio DRAWING INDEX Sheet Number Sheet Name ELECTRICAL E0.01 ELECTRICAL SYMBOL LEGEND & LUMINAIRE SCHEDULE E0.02 POWER DISTRIBUTION & LIGHTING CONTROL DIAGRAMS E0.03 ELECTRICAL PANEL SCHEDULES E1.01 DEMO - SERVICE LEVEL LIGHTING PLAN E1.02 DEMO - SHOW ROOM LIGHTING PLAN E1.03 DEMO - SERVICE LEVEL POWER PLAN E1.04 DEMO - SHOW ROOM POWER PLAN E2.01 NEW - SERVICE LEVEL LIGHTING PLAN E2.02 NEW - SHOW ROOM LIGHTING PLAN E2.03 NEW - SERVICE LEVEL POWER PLAN E2.04 NEW - SHOW ROOM POWER PLAN E3.01 SITE ELECTRICAL PLAN E4.01 ELECTRICAL SPECIFICATIONS E4.02 ELECTRICAL SPECIFICATIONS MECHANICAL M0.01 HVAC SPECIFICATIONS AND LEGEND M0.02 HVAC SCHEDULES AND DETAILS M1.01 DEMO - SERVICE LEVEL HVAC PLAN M1.02 DEMO - SHOW ROOM HVAC PLAN M2.01 NEW - SERVICE LEVEL HVAC PLAN M2.02 NEW - SHOW ROOM HVAC PLAN M3.01 HVAC ISOMETRIC DIAGRAMS PLUMBING P0.01 PLUMBING SPECIFICATIONS, SCHEDULES, AND DETAILS P1.01 PLUMBING PLANS DRAWING INDEX Sheet Number Sheet Name GENERAL G0.01 COVER SHEET G0.02 LIFE SAFETY PLAN ARCHITECTURAL AS.01 ARCHITECTURAL SITE PLAN A0.01 DEMO - SERVICE LEVEL PLAN A0.02 DEMO - SHOWROOM PLAN A0.03 DEMO - EXTERIOR ELEVATIONS A1.01 NEW - SERVICE LEVEL PLAN A1.02 NEW - SHOWROOM PLAN A1.03 NEW SERVICE LEVEL RCP A1.04 NEW SHOW ROOM RCP A1.05 ROOF PLAN A1.10 FURNITURE AND GRAPHICS PLANS A1.11 FINISH PLAN A1.21 WALL TYPES & DETAILS A2.01 EXTERIOR ELEVATIONS A3.11 WALL SECTIONS A3.12 WALL SECTIONS A3.21 WALL SECTION DETAILS A4.21 ENLARGED ELEVATOR PLANS, SECTION AND DETAILS A5.01 INTERIOR ELEVATIONS A5.11 MILLWORK SECTIONS & DETAILS A6.01 DOOR AND WINDOW SCHEDULES A6.02 FINISH SCHEDULE & VENDOR INFORMATION STRUCTURAL S0.01 GENERAL NOTES S1.01 DEMO - SERVICE LEVEL PLAN S1.02 DEMO - SHOW ROOM FLOOR PLAN S1.03 DEMO - ROOF PLAN S1.04 SERVICE LEVEL FOUNDATION PLAN S1.05 SHOW ROOM FLOOR FRAMING PLAN S1.06 SHOW ROOM SLAB PLAN S1.07 ROOF FRAMING PLAN S3.01 SECTIONS S3.02 SECTIONS S4.01 ENLARGED FRAMING PLAN S5.01 TYPICAL DETAILS DRAWING INDEX PROJECT RENDERING REQUIRED SUBMITTALS ARCHITECTURAL ROOFING / ROOFING SYSTEM METAL STUD FRAMING ACOUSTICAL CEILING TILE FLOOR AND WALL FINISHES GROUT FRP MILLWORK PLUMBING FIXTURES DOORS DOOR FRAMES DOOR HARDWARE OVERHEAD DOORS STOREFRONT / CURTAINWALL GLASS AND GLAZING FIRE EXTINGUISHERS AND CABINETS ALUMINUM COMPOSITE MATERIAL (ACM) JOINT SEALANT GUARDRAILS / RAILINGS AIR/WATER BARRIERS WALL INSULATION KNOXBOX COPING AS REQUIRED BY THE ARCHITECT. ENGINEERS WILL REQUIRE ADDITIONAL SUBMITTALS AS INDICATED IN THEIR SPECIFICATIONS PERMIT 10/7/2021

Transcript of PROJECT RENDERING DRAWING INDEX

Page 1: PROJECT RENDERING DRAWING INDEX

PROJECT TEAM:

ARCHITECT:CLIENT:

Architecture • Planning • Interiors • Preservation • Urban Design

www.arkinetics.com

architects + urbanists

STRUCTURAL ENGINEER:

2012 West 25th St., Suite 200Cleveland, OH 44113

P: 216. 227. 8505F: 216. 227. 8570

MECHANICAL / ELECTRICAL ENGINEER:

2012 West 25th St., Suite 200Cleveland, OH 44113

P: 216. 227. 8505F: 216. 227. 8570

MECHANICAL / ELECTRICAL ENGINEER:

2012 West 25th St., Suite 200Cleveland, OH 44113

P: 216. 227. 8505F: 216. 227. 8570

ANCHOR BOLTAIR CONDITIONINGACOUSTIC(AL)ACOUSTICAL CEILING TILEADJACENTABOVE FINISH FLOORALTERNATEALUMINUMANODIZEDAPPROXIMATEARCHITECT(URAL)AUTOMATIC

BOARDBETWEENBUILDINGBLOCK(ING)BULKHEADBEAMBOTTOMBRIDGINGBEARINGBRICKBASEMENTBUILT-UP ROOFING

CENTER TO CENTERCABINETCADMIUMCATCH BASINCEMENTCENTER LINECUBIC FEET PER MINUTECORNER GUARDCAST IRONCONTROL JOINTCEILINGCLOSETCLEARCONTRACT LIMIT LINECOUNTERCERAMIC MOSAIC TILECONCRETE MASONRY UNITCASED OPENING/CLEAN OUT

ABA/CACOUSACTADJAFFALTALUMANODAPPROXARCHAUTO

BDBETWBLDGBLKBLKHDBMBOTBRDGBRGBRKBSMTBUR

C/CCAB'TCADCBCEMCL orCFMCGCICJCLGCLCLRCLLCNTRCMTCMUCO

COLUMNCONCRETECONNECTIONCONSTRUCTIONCONTINUOUSCOORDINATECORRIDORCARPETCONCRETE SEALERCOURSECERAMIC TILECERAMIC TILE - PORCELAINCENTER

DEPTHDOUBLEDEGREESDEMOLITIONDRINKING FOUNTAINDIAMETERDIMENSIONDISPENSERDOWNDOORDOWN SPOUTDETAILDRAWINGDRAWERDRYWALL

EXPOSED STEELEXISTING TO REMAINEXISTING

FIRE ALARMFACE BRICKFAN COIL UNITFACE TO FACEFLOOR DRAINFOUNDATIONFIRE EXTINGUISHERFIRE EXTINGUISHER CABINETFIRE HOSE CABINETFINISH

COLCONCCONNCONSTCONTCOORD/CORRCPTCSCSLRCTCTPCTR

DDBLDEGDEMODFDIADIMDISPDNDRDSDETDWGDWRDW

ESETREXIST

FAFBFCUF/FFDFDNFEFECFHCFIN

FLOORFLUORESCENTFACE OF MASONRYFIRE RESISTANTFIBERGLASS REINFORCED PANELSFIRE-RETARDANT TREATEDFIRE-RETARDANT TREATED WOODFEETFOOTINGFURRINGFIRE VALVE CABINETFABRIC WALLCOVERING

GAUGEGALVANIZEDGENERAL CONTRACTORGLASSGRADEGYPSUM BOARDGYPSUM WALL BOARD

HIGHHOSE BIBBHOLLOW COREHARDBOARDHANDICAPPEDHARDWAREHARDWOODHOLLOW METAL HORIZONTALHIGH PERFORMANCE COATINGHIGH PRESSURE DECORATIVE LAMINATEHOURHEIGHTHEATINGHEATERHEATING, VENTILATION AIR CONDITIONINGHOT WATERHOT WATER HEATER

FLRFLUORFMFRFRP

FRTFRTWD

FTFTGFURRFVCFWC

GAGALVGCGLGRGYP BDGWB

HHBHCHDBDHDCPDHDWRHDWDHMHORIZHPC

HPDL

HRHTHTGHTRHVAC

HWHWH

INSIDE DIAMETERINCHINCLUDE (INCLUSIVE)INSULATIONINTERIOR

JANITORJOIST

KNOCK DOWNKNOCK OUT

LENGTH (LONG)LAMINATE(D)LAVATORYPOUNDLINEAR FEET (FOOT)LIMITEDLIGHTLIGHTINGLOUVER

MARBLEMASONRYMATERIALMAXIMUMMECHANICALMEMBRANEMANUFACTURERMANHOLEMINIMUMMISCELLANEOUSMASONRY OPENINGMOUNTEDMETALMULLION

NOT APPLICABLENOT IN CONTRACTNUMBERNOMINALNOT TO SCALE

IDININCLINSULINT

JANJST

KDKO

LLAMLAVLBLFLIMLTLTGLVR

MARBMASMATMAXMECHMEMBMFRMHMINMISCMOMTDMTLMULL

N/ANICNONOMNTS

OVERALLON CENTERON CENTER ABOVE FINISH FLOOR

OUTSIDE DIAMETEROVERHEAD DOOROPPOSITE HANDOVERFLOW ROOF DRAINOUT TO OUTOPENINGOPPOSITEOPTIONAL

PAVER TILEPARTICLE BOARDPRECAST CONCRETE POUNDS PER CUBIC FOOTPREFACED CONCRETE MASONRYPERIMETERPEG BOARDPLATEPLASTICPLASTIC LAMINATEPLUMBINGPREMOULDEDPANELPAINTPLYWOODPOLISHEDPAIRPREFINISHEDPREFABRICATEDPROJECTIONPRE-STRESS CONCRETEPOUNDS PER SQUARE FOOTPOUNDS PER SQUARE INCHPOINT/PAVER TILEPAINTEDPARTITIONPRESSURE TREATED WOODPOLYVINYLCHLORIDEPAVEMENT

OAOCOCAFF

ODOHDROPHOVRDO/OOP'GOPPOPT

PTPBDPCPCFPCM

PERIMPG BDPLPLASPLAMPLBGPMLDPNLPNTPLYWDPOLPRPREFINPREFABPROJPSCPSFPSIPTPTDPTNPTWDPVCPVMT

QUARRY TILEQUANTITY

RISERRETURN AIRRADIUSRETURN AIR GRILLEROOF DRAINRECEPTACLEREFRIGERATORREGISTERREINFORCEMENT (REINFORCING)REQUIREDRESILIENTRETURNREVISED (REVISION)RESINOUS FLOORINGROOMROUGH OPENINGREVERSE

SOLID CORESCHEDULE SMOKE DETECTORSADDLESECTIONSHEETSIMILARSLATESTAND PIPESPECIFICATIONSSPEAKERSPRINKLERSINGLE PLY ROOFINGSQUARESQUARE INCHSQUARE YARDSTAINLESS STEEL/ SLOP SINKSTANDARDSTEELSTORAGESTRUCTURE(AL)

QTQTY

RRARADRAGRDRECREFREGREINF

REQ'DRESRETREVRFRMRORVS

SCSCHEDSDSDLSECTSHTSIMSLTSPSPECSPKRSPKLRSPRSQSQ INSYSS

STDSTLSTORSTRUC

SUSPENDEDSHEET VINYLSEAMLESS VINYL - NON SLIPSEAMLESS VINYL SHEETSYSTEMS

THREADTONGUE AND GROOVETONGUE AND GROOVETRENCH DRAINTELEPHONETEMPORARYTEMPEREDTERRAZZOTEXTURETHICKTHRESHOLDTOP OF CONCRETE (TOP OF CURB)TOP OF STEELTOP OF DECKTOP OF MASONRYTOP OF JOISTTOP OF PARAPETTOP OF WALLTYPICAL

UNDERCUTUNDERGROUNDUNFINISHEDUNLIMITEDUNLESS NOTED OTHERWISEURINAL

VERTICALVESTIBULEVINYL COVEVINYL COMPOSITE TILEVERIFY IN FIELDVINYL STRAIGHTVINYL WALLCOVERING

SUSPSVSVNSSVSSYS

TT/G T&GTDTELTEMPTEMP'DTERTEXTHKTHLDTOC

TOSTODTOMTOJTOPTOWTYP

UCUGUNFINUNLIMUNOUR

VERTVESTVCVCTVIFVSVWC

WIDTHWITHWITHOUTWALL TO WALLWATER CLOSETWALL CARPETWOODWATER HEATERMOISTURE AND MOLD RESISTANT GYPSUM WALL BOARDWINDOWWIRE GLASSWEIGHTWELDED WIRE FABRIC

YARD

WW/W/OW/WWCWCARWDWHWGWB

WINWGWTWWF

YD

ABBREVIATION LEGEND: SYMBOLS

A8888

8

8

8 8

8

8

8

8

X

X

88A8888

INTERIOR AND EXTERIOR ELEVATION REFERENCE:

DRAWING NUMBER(S)

SHEET NUMBER

STRUCTURAL GRID:

NEW GRID

REFERENCE GRID

BUILDING, WALL, AND DETAIL SECTION REFERENCE:

DRAWING NUMBER

SHEET NUMBER

88A8888

ENLARGED PLAN OR DETAIL CALLOUT REFERENCE:

DRAWING NUMBER

SHEET NUMBER

888A

2-D-101

150 SF

ROOM NAME

FUNCTIONS

DOOR IDENTIFICATION:

NEW

888A

EXISTING

DOOR LETTER

DOOR NUMBER CORRESPONDS TO ROOM NUMBER

ROOM IDENTIFICATION:

ROOM NAME

ROOM NUMBER

ROOM AREA (WHEN INDICATED)

CEILING IDENTIFICATION:

WWW-88

88'-8"

CEILING TYPE

CEILING HEIGHT ABOVE FINISH FLOOR

WALL IDENTIFICATION:

WW88 A WALL TYPE. SEE CORRESPONDING SCHEDULES AND/OR DETAILS

KEYNOTE IDENTIFICATION:

KEYNOTE NUMBER; SEE CORRESPONDING NOTE ON KEYNOTE LEGEND ELSEWHERE ON SAME SHEET

?

FINISH FLOOR LEVEL

101.00

FINISH FLOOR LEVEL

101.00

LEVEL LINE, CONTROL POINT, OR DATUM:

NEW LEVEL

EXISTING LEVEL W

WINDOW / STOREFRONT GLAZING IDENTIFICATION:

WINDOW OR STOREFRONT GLAZING TYPE. SEE CORRESPONDING SCHEDULES AND/OR DETAILS.

1. ALL PRODUCT INSTALLATION SHALL BE PERFORMED ACCORDING TO MANUFACTURER'S WRITTEN SPECIFICATIONS AND INDUSTRY STANDARDS.

2. NO SUBSTITUTIONS SHALL BE MADE WITHOUT THE WRITTEN APPROVAL OF THE OWNER, CONTRACTOR AND ARCHITECT.

3. ALL CONTRACTORS SHALL BE LICENSED AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION.4. ALL CONTRACTORS SHALL INSPECT THE PROJECT AS RELATED TO THEIR SCOPES OF WORK AND

BECOME FAMILIAR WITH ALL EXISTING CONDITIONS AS REQUIRED FOR THE PROPER EXECUTION OF THEIR WORK.

5. ANY CONFLICTS OR INTERFERENCES OF THE PROPOSED WORK WITH THE EXISTING CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE GENERAL CONTRACTOR FOR RESOLUTION WITH THE OWNER AND ARCHITECT.

6. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING DISRUPTIONS TO THE UTILITIES AND SHALL INFORM THE OWNER OF SUCH ACTIVITIES.

7. "FURNISH" MEANS TO SUPPLY TO THE JOBSITE. "INSTALL" MEANS TO PLACE THE ITEM IN THE SPECIFIED LOCATION AND MAKE IT FUNCTIONAL. "PROVIDE" MEANS TO FURNISH & INSTALL.

8. THE JOBSITE SHALL BE KEPT FREE OF DEBRIS AND MADE BROOM-CLEAN EACH DAY.9. MOCK-UPS AND SAMPLES SHALL BE PROVIDED TO THE OWNER FOR ALL NEW FINISHES. MOCK-UPS

MAY BE PART OF THE FINAL WORK AND APPROVED BY THE OWNER AND ARCHITECT, PROVIDED OTHER REQUIREMENTS ARE MET.

10. ALL EXISTING CONDITIONS AND NEW WORK ARE "TYPICAL" UNLESS NOTED OTHERWISE.11. THE GENERAL CONTRACTOR AND SUB CONTRACTORS SHALL FAMILIARIZE THEMSELVES WITH ALL

EXISTING CONDITIONS PRIOR TO SUBMITTING THEIR BID, NOTIFY THE OWNER IMMEDIATELY OF ANY DISCREPANCIES.

12. ALL MATERIALS FURNISHED ON THE JOB SITE SHALL BE NEW AND STORED IN SUCH A MANNER AS TO PROTECT THEM FROM THE ELEMENTS.

13. DO NOT SCALE DRAWINGS, DIMENSIONS AND/OR EXISTING CONDITIONS GOVERN, NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES.

14. SUPPORT WIRES FOR CEILINGS, SOFFITS, ETC. SHALL NOT BE CONNECTED TO ANY MECHANICAL, ELECTRICAL, PLUMBING OR FIRE PROTECTION PIPING, ETC.

15. DURING CONSTRUCTION THE CONTRACTOR SHALL COORDINATE ALL ACTIVITIES WITH THE OWNER OR OWNER'S REPRESENTATIVE.

16. ENTRIES IN THE REVISION COLUMN OF ANY SCHEDULED ITEM INDICATE THAT THE ITEM HAS CHANGED IN THAT REVISION SEQUENCE. ITEMS REMOVED FROM THE PROJECT WILL NOT APPEAR IN SCHEDULES.

PROJECT GENERAL NOTES LOCATION AND SITE DATA

NORTHPROJECT LOCATION

DANIELJ.

BARNEY

0413550

TC

ETI

HCRADERE

T

SIG

ER

OI

HOFO

ETATS

DANIEL J. BARNEY , LICENSE#: 0413550

EXPIRATION DATE: 12/31/2021

arc

hit

ec

ts +

urb

an

ists

A

rchitectu

re •

Pla

nnin

g •

Inte

rio

rs •

Pre

serv

ation •

Urb

an D

esig

n

www.arkinetics.com

Cle

vela

nd O

ffic

e3723 P

earl R

oad

Cle

vela

nd,

OH

44109

DEALER CODE:

SHEET #:

DATE:

PROJECT #:

DRAWING TITLE:

arkinetics © 2021

DRAWN BY: CHECKED BY:

Arkinetics, Inc. and their Consultants shall be deemed the authors and owners of their respective Instruments of Service and shall retain all common law, statutory and other reserved rights, including copyrights. The Instruments of Service shall not be used for future additions or alterations to this Project or for other projects, without the prior written agreement of Arkinetics, Inc. Any unauthorized use of the Instruments of Service shall be at the Owner's sole risk and without liability to Arkinetics, Inc. and their Consultants

ISSUE:MARK:

P:

216.7

49.7

800

F:

216.7

49.1

300

OH011

C:\R

evit\M

arh

ofe

r H

yun

da-C

uyah

oga

Fa

lls_2

10

15.0

2_

rbe

nto

n6

XF

9T

.rvt

10

/7/2

021

10

:24

:31

PM

RO

N M

AR

HO

FE

R H

YU

ND

AI

Marh

ofe

r H

yu

nd

ai C

uya

ho

ga

Fa

lls1

26

0 M

ain

Str

ee

t, C

uya

ho

ga F

alls

, O

hio

COVER SHEET

G0.01

21015.02

BRP DB

RON MARHOFER HYUNDAIMarhofer Hyundai Cuyahoga Falls

1260 Main Street, Cuyahoga Falls, Ohio

DRAWING INDEX

SheetNumber Sheet Name

ELECTRICAL

E0.01 ELECTRICAL SYMBOL LEGEND & LUMINAIRESCHEDULE

E0.02 POWER DISTRIBUTION & LIGHTING CONTROLDIAGRAMS

E0.03 ELECTRICAL PANEL SCHEDULES

E1.01 DEMO - SERVICE LEVEL LIGHTING PLAN

E1.02 DEMO - SHOW ROOM LIGHTING PLAN

E1.03 DEMO - SERVICE LEVEL POWER PLAN

E1.04 DEMO - SHOW ROOM POWER PLAN

E2.01 NEW - SERVICE LEVEL LIGHTING PLAN

E2.02 NEW - SHOW ROOM LIGHTING PLAN

E2.03 NEW - SERVICE LEVEL POWER PLAN

E2.04 NEW - SHOW ROOM POWER PLAN

E3.01 SITE ELECTRICAL PLAN

E4.01 ELECTRICAL SPECIFICATIONS

E4.02 ELECTRICAL SPECIFICATIONS

MECHANICAL

M0.01 HVAC SPECIFICATIONS AND LEGEND

M0.02 HVAC SCHEDULES AND DETAILS

M1.01 DEMO - SERVICE LEVEL HVAC PLAN

M1.02 DEMO - SHOW ROOM HVAC PLAN

M2.01 NEW - SERVICE LEVEL HVAC PLAN

M2.02 NEW - SHOW ROOM HVAC PLAN

M3.01 HVAC ISOMETRIC DIAGRAMS

PLUMBING

P0.01 PLUMBING SPECIFICATIONS, SCHEDULES, ANDDETAILS

P1.01 PLUMBING PLANS

DRAWING INDEX

SheetNumber Sheet Name

GENERAL

G0.01 COVER SHEET

G0.02 LIFE SAFETY PLAN

ARCHITECTURAL

AS.01 ARCHITECTURAL SITE PLAN

A0.01 DEMO - SERVICE LEVEL PLAN

A0.02 DEMO - SHOWROOM PLAN

A0.03 DEMO - EXTERIOR ELEVATIONS

A1.01 NEW - SERVICE LEVEL PLAN

A1.02 NEW - SHOWROOM PLAN

A1.03 NEW SERVICE LEVEL RCP

A1.04 NEW SHOW ROOM RCP

A1.05 ROOF PLAN

A1.10 FURNITURE AND GRAPHICS PLANS

A1.11 FINISH PLAN

A1.21 WALL TYPES & DETAILS

A2.01 EXTERIOR ELEVATIONS

A3.11 WALL SECTIONS

A3.12 WALL SECTIONS

A3.21 WALL SECTION DETAILS

A4.21 ENLARGED ELEVATOR PLANS, SECTION ANDDETAILS

A5.01 INTERIOR ELEVATIONS

A5.11 MILLWORK SECTIONS & DETAILS

A6.01 DOOR AND WINDOW SCHEDULES

A6.02 FINISH SCHEDULE & VENDOR INFORMATION

STRUCTURAL

S0.01 GENERAL NOTES

S1.01 DEMO - SERVICE LEVEL PLAN

S1.02 DEMO - SHOW ROOM FLOOR PLAN

S1.03 DEMO - ROOF PLAN

S1.04 SERVICE LEVEL FOUNDATION PLAN

S1.05 SHOW ROOM FLOOR FRAMING PLAN

S1.06 SHOW ROOM SLAB PLAN

S1.07 ROOF FRAMING PLAN

S3.01 SECTIONS

S3.02 SECTIONS

S4.01 ENLARGED FRAMING PLAN

S5.01 TYPICAL DETAILS

DRAWING INDEXPROJECT RENDERING

REQUIRED SUBMITTALS

ARCHITECTURAL• ROOFING / ROOFING SYSTEM• METAL STUD FRAMING• ACOUSTICAL CEILING TILE• FLOOR AND WALL FINISHES• GROUT• FRP• MILLWORK• PLUMBING FIXTURES• DOORS• DOOR FRAMES• DOOR HARDWARE• OVERHEAD DOORS• STOREFRONT / CURTAINWALL• GLASS AND GLAZING• FIRE EXTINGUISHERS AND CABINETS

• ALUMINUM COMPOSITE MATERIAL (ACM)• JOINT SEALANT• GUARDRAILS / RAILINGS• AIR/WATER BARRIERS• WALL INSULATION• KNOXBOX• COPING

AS REQUIRED BY THE ARCHITECT. ENGINEERS WILL REQUIRE

ADDITIONAL SUBMITTALS AS INDICATED IN THEIR SPECIFICATIONS

PERMIT 10/7/2021