NO. 3 TO THE DRAWINGS AND THE PROJECT MANUAL PROJECT NAME: Polser Elementary School 20 YR Refresh and Donald Elementary STEM; Hebron Valley Elementary School Re-Roof; and The Colony High School Softball and Athletics CLIENT NAME: Lewisville ISD LOCATION: Flower Mound, Carrollton, and The Colony, Texas PROJECT NUMBER: 01743-12-01, 1743-15-02 and 1743-15-01; 1743-06-01; and 1743-11-00 PROPOSAL DATE: Thursday, March 1, 2018, 2:00 PM ADDENDUM DATE: Friday, February 16, 2018 For additional information regarding this project, contact Lorin Scarborough at 800.687.1229. THIS ADDENDUM INCLUDES: Structural Items 0 Pages Architectural Items 3 Pages Foodservice Items 0 Pages Plumbing Items 0 Pages Mechanical Items 0 Pages Electrical Items 0 Pages Technology Items 0 Pages AND ALL ATTACHED REVISED DRAWING REFERENCES IN THE ADDENDUM 10-05-15 2-15-18

Transcript of PROJECT NUMBER - Huckabee · brg bearing brk brick brv base, rubber vented btc base, ceramic tile...

  • NO. 3

    TO THE DRAWINGS AND THE PROJECT MANUAL

    PROJECT NAME: Polser Elementary School 20 YR Refresh and Donald Elementary

    STEM; Hebron Valley Elementary School Re-Roof; and The Colony High School Softball

    and Athletics

    CLIENT NAME: Lewisville ISD

    LOCATION: Flower Mound, Carrollton, and The Colony, Texas

    PROJECT NUMBER: 01743-12-01, 1743-15-02 and 1743-15-01; 1743-06-01; and 1743-11-00

    PROPOSAL DATE: Thursday, March 1, 2018, 2:00 PM

    ADDENDUM DATE: Friday, February 16, 2018

    For additional information regarding this project, contact Lorin Scarborough at

    800.687.1229.

    THIS ADDENDUM INCLUDES:

    Structural Items 0 Pages

    Architectural Items 3 Pages

    Foodservice Items 0 Pages

    Plumbing Items 0 Pages

    Mechanical Items 0 Pages

    Electrical Items 0 Pages

    Technology Items 0 Pages

    AND ALL ATTACHED REVISED DRAWING REFERENCES IN THE ADDENDUM

    10-05-152-15-18

  • Project Name: Polser Elementary School 20 YR Refresh and Donald Elementary School STEM;

    Hebron Valley Elementary School Re-Roof; and The Colony High School Softball and Athletics

    Client: Lewisville ISD

    Flower Mound; Carrollton; and The Colony, Texas

    Project Number: 01743-12-01, 1743-15-02 and 1743-15-01; 1743-06-01; and 1743-11-00

    Architectural Items For

    Addendum No. 3

    Page 1 of 3

    ARCHITECTURAL ITEMS FOR ADDENDUM NO. 3 NOTICE TO PROPOSERS:

    A. This Addendum shall be considered part of the contract documents for the above-mentioned project as though it had

    been issued at the same time and incorporated integrally therewith. Where provisions of the following supplementary

    data differ from those of the original contract documents, this Addendum shall govern and take precedence.

    B. Proposers are hereby notified that they shall make any necessary adjustments in their estimate on account of this

    Addendum. It will be construed that each Proposer’s proposal is submitted with full knowledge of all modifications and

    supplemental data specified therein. Acknowledge receipt of this addendum in the space provided on the proposal

    form. Failure to do so may subject Proposer to disqualification.

    REFERENCE IS MADE TO THE PROJECT MANUAL AND THE DRAWINGS AS NOTED:

    POLSER ELEMENTARY SCHOOL 20 YR REFRESH AND DONALD ELEMENTARY SCHOOL STEM

    PROJECT MANUAL - POLSER AND DONALD:

    AD No 3, Arch. Item 1: To the Project Manual, SECTION 00 7343, “WAGE RATE REQUIREMENTS,”

    Replace the tables in this section with the attached “Prevailing Wage Rates - School Construction Trades.”

    DRAWINGS - POLSER AND DONALD:

    AD No 3, Arch. Item 2: To the Drawings, Set, “DONALD ELEMENTARY SCHOOL STEM RENOVATION,”

    Refer to attached drawing set, added sheets G1.1 to ET.12. This replaces corresponding items issued in Addendum 1 on

    February 12, 2018: AD No 1, Arch Item 3; AD No1, Plumb Item 1; AD No 1, Mech Item 1; AD No1 Elec Item 6; and AD No 1, Tech

    Item 1.

    GENERAL

    G1.1 COVER SHEET

    G1.2 GENERAL DATA

    G3.1 INTERIOR PARTITION TYPES

    G3.2 TYPICAL INTERIOR PARTITION BRACING DETAILS

    ARCHITECTURAL

    AD1.1 DEMOLITION FLOOR PLAN - SECTION 2

    AD1.2 DEMOLITION FLOOR PLAN - SECTION 3

    A1.1 MASTER PLAN

    A1.2 FLOOR PLAN - SECTION 1

    A1.3 FLOOR PLAN - SECTION 2

    A1.4 FLOOR PLAN - SECTION 3

    A1.5 FLOOR PLAN - SECTION 4

    A2.1 REFLECTED CEILING PLAN - SECTION 2

    10-05-152-15-18

  • Project Name: Polser Elementary School 20 YR Refresh and Donald Elementary School STEM;

    Hebron Valley Elementary School Re-Roof; and The Colony High School Softball and Athletics

    Client: Lewisville ISD

    Flower Mound; Carrollton; and The Colony, Texas

    Project Number: 01743-12-01, 1743-15-02 and 1743-15-01; 1743-06-01; and 1743-11-00

    Architectural Items For

    Addendum No. 3

    Page 2 of 3

    A3.1 WINDOW SCHEDULE, CONFIGURATIONS AND DETAILS

    A4.1 INTERIOR ELEVATIONS

    A8.1 CASEWORK ELEVATIONS

    A8.2 CASEWORK ELEVATIONS AND DETAILS

    PLUMBING

    PL1.1 PLUMBING FLOOR PLAN - SECTION 2

    MECHANICAL

    MH1.1 MECHANICAL FLOOR PLANS - SECTION 3

    ELECTRICAL

    E0.1 ELECTRICAL AND LIGHTING NOTES AND SYMBOLS

    ED1.1 ELECTRICAL DEMOLITION FLOOR PLAN - SECTION 2

    ED1.2 ELECTRICAL DEMOLITION FLOOR PLAN - SECTION 3

    EP1.2 ELECTRICAL FLOOR PLAN - SECTION 3

    EP7.1 ELECTRICAL AND LIGHTING DETAILS

    EP7.2 LUMINAIRE SCHEDULE AND CONTROLS CHART

    LIGHTING

    EL1.1 LIGHTING FLOOR PLAN - SECTION 2

    EL1.2 LIGHTING FLOOR PLAN - SECTION 3

    TECHNOLOGY

    ET1.2 ELECTRICAL COMMUNICATION FLOOR PLAN - SECTION 3

    HEBRON VALLEY ELEMENTARY SCHOOL RE-ROOF

    FOR CLARIFICATION: THE PROJECT POSTED ON THE HUCKABEE WEBSITE AS “HEBRON VALLEY ELEMENTARY

    SCHOOL ROOF REPLACEMENT,” PROJECT NUMBER 1743-06-01, HAS BEEN COMBINED INTO THE PROJECT NAMED

    “POLSER ELEMENTARY SCHOOL 20 YR REFRESH AND DONALD ELEMENTARY STEM; HEBRON VALLEY ELEMENTARY

    SCHOOL RE-ROOF; AND THE COLONY HIGH SCHOOL SOFTBALL AND ATHLETICS.” PROJECT NUMBER: 01743-12-01,

    1743-15-02 AND 1743-15-01; 1743-06-01; AND 1743-11-00.

    PROJECT MANUAL - HEBRON VALLEY:

    AD No 3, Arch. Item 3: To the Project Manual, SECTION 00 7343, “WAGE RATE REQUIREMENTS,”

    Replace the tables in this section with the attached “Prevailing Wage Rates - School Construction Trades.”

    DRAWINGS - HEBRON VALLEY: N/A

  • Project Name: Polser Elementary School 20 YR Refresh and Donald Elementary School STEM;

    Hebron Valley Elementary School Re-Roof; and The Colony High School Softball and Athletics

    Client: Lewisville ISD

    Flower Mound; Carrollton; and The Colony, Texas

    Project Number: 01743-12-01, 1743-15-02 and 1743-15-01; 1743-06-01; and 1743-11-00

    Architectural Items For

    Addendum No. 3

    Page 3 of 3

    THE COLONY HIGH SCHOOL SOFTBALL AND ATHLETICS

    FOR CLARIFICATION: THE PROJECT POSTED ON THE HUCKABEE WEBSITE AS “THE COLONY HIGH SCHOOL NEW

    SOFTBALL AND ATHLETIC BUILDINGS RENOVATION,” PROJECT NUMBER 1743-11-00, HAS BEEN COMBINED INTO

    THE PROJECT NAMED “POLSER ELEMENTARY SCHOOL 20 YR REFRESH AND DONALD ELEMENTARY STEM; HEBRON

    VALLEY ELEMENTARY SCHOOL RE-ROOF; AND THE COLONY HIGH SCHOOL SOFTBALL AND ATHLETICS.” PROJECT

    NUMBER: 01743-12-01, 1743-15-02 AND 1743-15-01; 1743-06-01; AND 1743-11-00.

    PROJECT MANUAL - THE COLONY:

    AD No 3, Arch. Item 4: To the Project Manual, SECTION 00 7343, “WAGE RATE REQUIREMENTS,”

    Replace the tables in this section with the attached “Prevailing Wage Rates - School Construction Trades.”

    DRAWINGS - THE COLONY: N/A

    END OF ARCHITECTURAL ADDENDUM

  • Sheet No.Job No.

    Drawn By:

    Date:

    Pro

    ject

    :

    Copyright © 2018, Huckabee & Associates, Inc.

    VOLUMEPACKAGE

    C:\

    Use

    rs\e

    torr

    es\D

    ocu

    men

    ts\1

    743-

    15-0

    1_D

    on

    ald

    ES

    Ren

    ova

    tio

    n -

    AR

    CH

    _v16

    _eto

    rres

    .rvt

    2/12

    /201

    8 2:

    43:1

    4 P

    M

    LVS

    G1.1

    COVER SHEET

    2/12/2018

    1743-15-01

    DO

    NA

    LD E

    LEM

    EN

    TAR

    Y S

    CH

    OO

    LS

    TEM

    RE

    NO

    VA

    TIO

    NFO

    RLE

    WIS

    VIL

    LE I.

    S.D

    .FL

    OW

    ER

    MO

    UN

    D, T

    EX

    AS

    Rev

    isio

    n /

    Dat

    e

    10-05-152-12-18

  • INDEX OF SHEETS

    AREA MAP

    ENLARGED AREA AUSTIN

    HOUSTON

    DFW

    LIST OF ABBREVIATIONS

    CEMENT OR MORTAR BOARD

    METAL (SMALL SCALE)

    FINISH WOOD

    GYPSUM BOARD

    TERRAZZO

    ALUMINUM (LARGE SCALE)

    PLASTER ON METAL LATH(LARGE SCALE)

    METAL (LARGE SCALE)

    SAND PLASTER or CEMENT FINISH

    ROUGH WOOD BLOCKING(INTERRUPTED)

    ROUGH WOOD BLOCKING(CONTINUOUS)

    PLYWOOD

    ACOUSTICAL TILE

    RIGID INSULATION

    BATT INSULATION or LOOSE FILL

    STONE

    CONCRETE

    FACE BRICK

    STONE PRE-CAST

    MARBLE OR GRANITE

    LIGHT-WEIGHT CONCRETE BLOCK

    UNDISTURBED EARTH

    EARTH COMPACTED

    NOTE: NOT ALL MATERIALS SHOWN MAY BE USED ON THIS PROJECT

    BURNISHED CONCRETE BLOCK

    SIMULATED STONE CONCRETE BLOCK

    LEGEND OF MATERIALS

    SITE LOCATION MAPAB ANCHOR BOLTA/C AIR CONDITIONERADDN'L ADDITIONALADJ ADJUSTABLEADH ADHESIVEAFF ABOVE FINISHED FLOORAFG ABOVE FINSIHED GRADEAHU AIR HANDLING UNITALT ALTERNATEALUM ALUMINUMAP ACOUSTICAL PANELSAPPROX APPROXIMATEARCH ARCHITECTURAL

    B BEYONDB/B BACK TO BACKBL BUILDING LINEBLDG BUILDINGBLKG BLOCKINGBM BEAMBOD BOTTOM OF METAL DECKBOG BOTTOM OF GUTTERBOM BOTTOM OF MASONRYBOS BOTTOM OF STEELBOT BOTTOMBP BASE, PORCELAIN TILEBQ BASE, QUARRY TILEBR BASE, RUBBERBRES BASE, RESINOUSBRG BEARINGBRK BRICKBRV BASE, RUBBER VENTEDBTC BASE, CERAMIC TILEBTWN BETWEENBTZP BASE, PRECAST TERRAZZOBTZ BASE, TERRAZZOBW BOTH WAYS

    C CHANNELC/C CENTER TO CENTERCAB CABINETCAD CADMIUMCI CAST IRONCJ CONTROL JOINTCL CENTERLINECLG CEILINGCLR CLEARCMU CONCRETE MASONRY UNITCNTRD CENTEREDCO CLEAN OUTCOL COLUMNCONC CONCRETECONN(S) CONNECTION(S)CONT CONTINUOUSCOORD COORDINATECOP POLISHED CONCRETECORR CORRIDORCOS CONCRETE (SEALED)CPT ROLLED CARPETCPTW WALL CARPETCPY CANOPYCS CAST STONECSM CONCRETE STONE MASONRYCU CONDENSING UNITCUST CUSTODIANCT CARPET TILE

    DBL DOUBLEDET DETAILDH DOOR HARDWAREDIA DIAMETERDIAG DIAGONALDIM DIMENSIONDN DOWNDS DOWNSPOUTDRWG DRAWINGDWR DRAWER

    EA EACHEB EXPANSION BOLTEF EACH FACEEJ EXPANSION JOINTEL ELEVATIONELEC'L ELECTRICALELEV ELEVATORENGR ENGINEEREPT EPOXY PAINTEQ EQUAL (EQUALLY)EW EACH WAYEWC ELECTRIC WATER COOLEREXIST EXISTINGEXP EXPANSIONEXT EXTERIOR

    F/F FACE TO FACEFD FLOOR DRAINFDN FOUNDATIONFEC FIRE EXTINGUISHER CABINETFFE FINISHED FLOOR ELEVATIONFG FIBERGLASSFHC FIRE HOSE CABINETFIN FINISH(ED)FIN FLR FINISHED FLOORFLG FLANGEFLR FLOORFS FAR SIDEFSAP FIXED SOUND ABSORPTIVE PNLSFTG FOOTINGFV FIELD VERIFY

    GA GAGE OR GAUGEGALV GALVANIZEDGB GRAB BARGEN GENERALGMU GLAZED MASONRY UNITGPL PLASTER/GYPSUM PLASTERGR BM GRADE BEAMGRF GROUND FACE/BURNISHED CMUGUT GUTTERGYP GYPSUM BOARD

    HB HOSE BIBHC HANDICAPHD BD HARD BOARDHDWD HARD WOODHFB HOLLOW FACE BRICKHM HOLLOW METALHORIZ HORIZONTALHP HIGH POINTHT HEIGHTHVAC HEATING, VENTILATION, & A/C

    ICF INSULATED CONCRETE FORMSID INSIDE DIAMETERIF INSIDE FACEIND BD INDUSTRIAL BAORDINFO INFORMATIONINSUL INSULATIONINT INTERIOR

    JT JOINTJST(S) JOIST(S)

    L ANGLELAV LAVATORYLLH LONG LEG HORIZONTALLLV LONG LEG VERTICALLONG LONGITUDINALLRP LOW POINT

    MAS MASONRYMAT'L MATERIALMAX MAXIMUMMB MARKERBOARDMDF MEDIUM DENSITY FIBERCOREMECH MECHANICALMEZZ MEZZANINEMFR MANUFACTURERMIN MINUIMUMMISC MISCELLANEOUSMO MASONRY OPENINGMP METAL WALL PANELSMS MOP SINKMTL METAL

    NB NO BASENF NO FINISHNIC NOT IN CONTRACTNO NUMBERNS NATURAL STONENTS NOT TO SCALE

    OC ON CENTEROCEW ON CENTERS EACH WAYOD OUTSIDE DIAMETEROF OUTSIDE FACEOH OPPOSITE HANDOHD OVERHEADOPP OPPOSITEOS OVERFLOW SCUPPER

    P/C PRECAST CONCRETEPB PIPE BRACEPEN PENETRATIONPERIM PERIMETERPERP PERPENDICULARPL PLATEPLC PLASTIC LAMINATE CASEWORKPLP PLASTIC LAMINATE-FACED WOOD PANELPNT PAINTPPL PLASTER (PORTLAND CEMENT)PROJ PROJECTIONPT POINTPW PLYWOOD

    QTZ QUARTZ

    R RISERRAD RADIUSRAFF RESILIENT FLUID APPLIED FLOORINGRAFS RESILIENT ROLLED RUBBER FLOORINGRAFT RESILIENT ATHLETIC FLOORING TILERAFV RESILIENT ATHLETIC FLOORING VINYLRD ROOF DRAINREF REFERENCEREINF REINFORCINGREM REMAINDERRES RESINOUS FLOORINGREQ'D REQUIREDRF RIGID FRAMERO ROUGH OPENINGRTU ROOFTOP UNIT

    SB SPLASH BLOCKSCHED SCHEDULESEC SECURITYSECT SECTIONSHT SHEETSIM SIMILARSJ SAWN JOINTSMO SCHEDULED MASONRY OPENINGSP SPACESPEC SPECIFICATIONSSPF SPLIT-FACE CONCRETE MASONRY UNITSPS SOLID POLYMER SURFACE MATERIALSS STAINLESS STEELSTD STANDARDSTIFF STIFFENERSTIR STIRRUPSSTL STEELSTN STAINSTOR STORAGESTRUCT STRUCTURESTU STUCCOSUPT SUPPORTSVT SOLID VINYL TILESYMM SYMMETRICAL

    T&B TOP & BOTTOMT&G TONGUE & GROOVETC CERAMIC TILETH THRESHOLDTLT TOILETTMD TOP OF METAL DECKTOB TOP OF BEAMTOBB TOP OF CMU BOND BEAMTOBR TOP OF BRICKTOC TOP OF CURBTOCP TOP OF CONCRETE PANELTOF TOP OF FOOTINGTOJ TOP OF JOISTTOM TOP OF MASONRYTOP TOP OF PIERTOPC TOP OF PIER CAPTOS TOP OF STEELTOSC TOP OF STRUCTURAL CONCRETETOSF TOP OF METAL STUD FRAMINGTOSS TOP OF STRUCTURAL STEELTOT TOP OF STEEL TRUSSTOW TOP OF WALLTOWD TOP OF WOOD BLOCKING/ NAILERTPC PORCELAIN TILETQ QUARRY TILETRAN TRANSVERSETRIM METAL FLASHINGS AND COPINGSTS TUBE STEELTYP TYPICALTZ TERRAZZOTZE TERRAZZO EPOXYTZT TERRAZZO TILE

    U URINALUNO UNLESS NOTED OTHERWISE

    VCT VINYL COMPOSITION TILEVERT VERTICAL

    W/ WITHW/O WITHOUTWASH WASHSTATIONWC WATERCLOSETWD WOODWH WATERHEATERWMP MAPLE WOOD ATHLETIC FLOORINGWMS MASONITE WOOD BLOCKINGWP WORKPOINTWS WATERSTOPWCT WALK-OFF CARPET TILEWT WEIGHTWVC WOOD VENEER CASEWORKWWF WELDED WIRE MESH (FABRIC)

    XB X-BRACING

    >= LARGER THAN OR EQUAL TO

  • 5/8" GYP BD

    MTL STUD @ 16" OC HORIZ -REF PLAN

    5/8" GYP BD

    STUDWIDTH

    PARTITIONWIDTH

    WALLTYPE

    STUDWIDTH

    PARTITIONWIDTH

    FIRERATING UL LISTING

    NO SOUNDATTENUATION

    WITH SOUNDATTENUATION NOTES

    STC RATING

    H4 3 5/8" 4 7/8" --- U419; U465 40 44

    H4 3 5/8" 4 7/8" 1 HR U419; U465 40 44

    H6 6" 7 1/4" --- U419; U465 40 44

    H6 6" 7 1/4" 1 HR U419; U465 40 44

    BATT INSULATION

    5/8" GYP BD

    MTL STUD @ 16" OC HORIZ -REF PLAN

    HORIZ BRACING AT 48" OCVERT

    STUDWIDTH

    MTL RUNNER BELOW

    PARTITIONWIDTH

    WALLTYPE

    STUDWIDTH

    PARTITIONWIDTH

    FIRERATING UL LISTING

    NO SOUNDATTENUATION

    WITH SOUNDATTENUATION NOTES

    STC RATING

    M2 1 5/8" 2 1/4" ---

    M3 2 1/2" 3 1/8" --- 27

    M4 3 5/8" 4 1/4" --- 27

    M6 6" 6 5/8" ---

    M1 7/8" 1 1/2" --- N/A

    7/8" HAT CHANNEL AT TYPE M1

    PARTITION NOTES:

    1) ALL INTERIOR PARTITIONS NOT OTHERWISE DESCRIBED BY A WALL SECTION ARE IDENTIFIED BY A GRAPHICSYMBOL REPRESENTING HEIGHT AND ACOUSTICAL PROPERTIES, WITH AN ALPHANUMERIC CODE INDICATINGMATERIALS (BY LETTER) AND NOMINAL THICKNESS OF STRUCTURE (BY NUMBER).

    2) UNTAGGED PARTITIONS AND COLUMN FURRINGS SHOULD BE ASSUMED TO BE "STANDARD" FOR BIDDINGPURPOSES. THE "STANDARD" GYP BOARD PARTITION IS TYPE H4, ACOUSTICAL, TO 6" ABOVE CEILING, AND THE"STANDARD" GYP BOARD COLUMN FURRING AND CHASES IS M4, NON-ACOUSTICAL, TO 6" ABOVE CEILING U.N.O.THE "STANDARD" MASONRY PARTITION IS TYPE A8, NON-ACOUSTICAL AND THE "STANDARD" MASONRY COLUMNFURRING IS A6, NON-ACOUSTICAL. CMU IS TO EXTEND 4" ABOVE CEILING OR NEAREST 8" COURSING ABOVECEILING. ANY UNTAGGED PARTITIONS WHICH APPEAR TO BE INCONSISTENT WITH THESE "STANDARD"DESCRIPTIONS SHOULD BE VERIFIED WITH THE ARCHITECT PRIOR TO CONSTRUCTION.

    3) WALL TYPES IDENTIFIED AS CMU MAY INCLUDE ACMU. FLOOR PLAN HATCH PATTERNS WILL DIFFERENTIATEREGULAR SMOOTH FACE CMU FROM ARCHITECTURAL CMU. FINISH PLANS AND SCHEDULES WILL IDENTIFY ACMUSELECTIONS (GROUND FACE, SPLIT FACE, ETC.) AND IDENTIFY WHICH SIDE OF A SINGLE WYTHE ACMU WALL IS THEFINISH SIDE.

    4) WALL TYPES IDENTIFIED AS INCLUDING VENEER MAY INCLUDE BRICK, STONE, OR ACMU. FLOOR PLAN HATCHPATTERNS WILL DIFFERENTIATE REGULAR SMOOTH FACE CMU, BRICK, STONE, OR ARCHITECTURAL CMU. FINISHPLANS AND SCHEDULES WILL IDENTIFY ACMU SELECTIONS (GROUND FACE, SPLIT FACE, ETC.)

    5) WALLS INDICATED BY TAG "GYP WALL ABOVE TO DECK" SHALL BE CONSTRUCTED OF THE SPECIFIED WALL TYPETO A POINT ABOVE THE CEILING, BRACED, AND AN H4 (OR M4) PARTITION (H6 OR M6 WHERE REQUIRED BYUNBRACED HEIGHT) SHALL BE BUILT FROM THE TOP OF WALL TO DECK. WALLS INDICATED BY TAG "ACOUSTICALGYP WALL ABOVE TO DECK" SHALL BE CONSTRUCTED OF THE SPECIFIED WALL TYPE TO A POINT ABOVE THECEILING, BRACED, AND AN H4 (OR M4) PARTITION (H6 OR M6 WHERE REQUIRED BY UNBRACED HEIGHT) WITH BATTINSULATION SHALL BE BUILT FROM THE TOP OF WALL TO DECK. WHERE INDICATED BY THE FIRE CODE PLAN TO BEFIRE RATED, ALL CONNECTIONS SHALL MEET RATING REQUIREMENTS.

    6) FIRE RATED PARTITIONS ARE INDICATED ON THE FIRE CODE PLANS ON THE G2 SHEETS. ALL GYP BOARD IN AFIRE RATED ASSEMBLY MUST BE 5/8" TYPE "X" AND CONSTRUCTION MUST MATCH THE ASSIGNED UL NUMBER.REFERENCE THE TYPE SCHEDULES ON THIS SHEET FOR UL NUMBERS WHERE APPLICABLE. WHERE ALLOWED BYTHE LOCAL CODE OFFICIALS, ALTERNATE UL ASSEMBLIES MAY BE PRESENTED FOR THE CONSIDERATION OF THEARCHITECT AND THE CODE OFFICIALS, BUT MUST NOT BE USED UNLESS APPROVED IN WRITING. PARTITIONS NOTIDENTIFIED ON THE G2 SHEETS AS FIRE RATED MAY BE BUILT WITH STANDARD GYP BOARD AND ARE NOTREQUIRED TO MEET LISTED UL ASSEMBLY REQUIREMENTS.

    7) WHERE FIRE RATED MASONRY PARTITIONS ARE INDICATED TO EXTEND TO DECK, ANY VENEER OR ACMU MAYTERMINATE ABOVE CEILING LEVEL. THE CMU WALL SHALL EXTEND TO DECK WITH REGULAR CMU OF SAMETHICKNESS AS THE CMU (OR ACMU) IN THE WALL ASSEMBLY.

    8) PARTITIONS INDICATED TO RECEIVE SOUND ATTENUATION SHALL INCLUDE INSULATION FULL HEIGHT U.N.O.SOUND ATTENUATED GYP BOARD PARTITIONS SHALL INCLUDE SOUND ATTENUATING BATT INSULATION. SOUNDATTENUATED CMU WALLS SHALL HAVE ALL UNREINFORCED CORES FILLED WITH FOAMED IN PLACE INSULATION.FLOOR TRACK OF SOUND RATED GYP WALLS SHALL BE SET IN A CONTINUOUS BED OF SEALANT.

    9) ALL COLD FORM METAL FRAMING (METAL STUDS) ARE SUBJECT TO THE DESIGN OF A QUALIFIED STRUCTURALENGINEER. FINAL DETERMINATION OF GUAGE AND DIMENSIONS OF FRAMING WILL BE DETERMINED BYSTRUCTURAL DESIGN. ENGINEERS RECOMMENDATIONS WHICH WOULD SIGNIFICANTLY IMPACT WALL THICKNESSMUST BE COORDINATED WITH THE ARCHITECT FOR ALIGNMENT PRIOR TO CONSTRUCTION.

    10) REFER TO TYPICAL INTERIOR PARTITION BRACING DETAILS FOR ADDITIONAL INFORMATION REGARDING FLOORAND DECK CONNECTIONS. FIRE RATED WALLS SHALL USE FIRE STOPPING SEALANTS OR ASSEMBLIES WHERE THEWALL ABUTS THE DECK, INCLUDING MINERAL WOOL INSULATION WHERE APPLICABLE. NON-RATED PARTITIONSSHALL USE ACOUSTICAL SEALANTS AND SAB INSULATION WHERE THE WALL ABUTS THE DECK.

    11) FOR ANY DESCREPENCY BETWEEN PARITITON TYPES AND WALL SECTIONS, WALL SECTION SHALL SUPERCEDE.

    12) NOT ALL PARTITION TYPES SHOWN WILL BE USED IN EVERY PROJECT.

    PARTITION TYPE TAGS

    A3

    LETTER INDICATES PARTITION TYPE.

    NUMBER INDICATES STUD OR CMU SIZE AS FOLLOWS:1 - 7/8" HAT CHANNEL2 - 1 5/8" METAL STUD3 - 2 1/2" METAL STUD4 - 3 5/8" METAL STUD OR CMU6 - 6" METAL STUD OR 5 5/8" CMU8 - 8" METAL STUD OR 7 5/8" CMU12 - 11 5/8" CMU

    WALL ASSEMBLY IN PLAN VIEW

    A3

    A3

    A3

    A3

    A3

    PARTITION TYPE TAG SHAPES

    A3

    WALL TO DECK

    WALL TO 6" ABOVE CEILING

    FIRE RATED WALL TO DECK

    ACOUSTICAL WALL TO DECK

    ACOUSTICAL WALL TO 6" ABOVE CEILING

    ACOUSTICAL FIRE RATED WALL TO DECK

    INTERIOR PARTITION TYPE LEGEND

    Sheet No.Job No.

    Drawn By:

    Date:

    Pro

    ject

    :

    Copyright © 2018, Huckabee & Associates, Inc.

    VOLUMEPACKAGE

    C:\

    Use

    rs\e

    torr

    es\D

    ocu

    men

    ts\1

    743-

    15-0

    1_D

    on

    ald

    ES

    Ren

    ova

    tio

    n -

    AR

    CH

    _v16

    _eto

    rres

    .rvt

    2/12

    /201

    8 2:

    43:1

    6 P

    M

    JMA

    G3.1

    INTERIOR PARTITION TYPES

    2/12/2018

    1743-15-01

    DO

    NA

    LD E

    LEM

    EN

    TAR

    Y S

    CH

    OO

    LS

    TEM

    RE

    NO

    VA

    TIO

    NFO

    RLE

    WIS

    VIL

    LE I.

    S.D

    .FL

    OW

    ER

    MO

    UN

    D, T

    EX

    AS

    1 1/2" = 1'-0"HWALL TYPE H - GYP BOARD ON METAL STUD

    1 1/2" = 1'-0"MWALL TYPE M - GYP BOARD FURRING

    Rev

    isio

    n /

    Dat

    e

    10-05-152-12-18

  • 1'-0

    "H

    EIG

    HT

    VA

    RIE

    S -

    RE

    F. R

    CP

    BASE AS SCHED.

    FLOORING AS SCHED.

    CONC. SLAB - REF. STRUCT.

    SOUND BATT INSUL.

    MTL. STUD FRAMING @ 16" O.C.(REF. PLAN FOR SIZE)

    CEILING AS SCHED.

    SOUND BATT INSUL.2'-0" WIDE EACH SIDE OFINTERIOR PARTITIONS.

    5/8" GYP. BD. ON EA. SIDE OFMTL. STUD FRAMING @ 16" O.C.(REF. PLAN FOR SIZE)

    20 GA.BOTTOM

    TRACK

    20 GA. TOPTRACK

    BRACING AS REQ'D. - REF.STRUCT.

    HE

    IGH

    T V

    AR

    IES

    - R

    EF

    . RC

    P

    GYP. BD. TO WITHIN 1/4" OFFLOOR SLAB. SEALANT W/ FIRESEALANT EA. SIDE @ FIRE RATEDPARTITION; SEALANT W/ACOUSTICAL SEALANT @ SOUNDPARTITION

    BASE AS SCHED.

    FLOORING AS SCHED.

    CONC. SLAB - REF. STRUCT.

    SOUND BATT INSUL.

    MTL. STUD FRAMING @ 16" O.C.(REF. PLAN FOR SIZE)

    CEILING AS SCHED.

    20 GA.BOTTOM

    TRACK

    FIRERATED

    PARTITION

    SOUNDPARTITIO

    N

    FLOOR SLAB OR ROOF DECKASSEMBLY

    REFER TO CODE SUMMARY PLANFOR LOCATIONS

    1-1/2" = 1'-0"

    1 HR. ASSEMBLY: UL U465 1LAYER OF 5/8" TYPE "X" GYP. BD.ON EA. SIDE OF MTL. STUDFRAMING @ 16" O.C. (REF. PLANFOR SIZE)

    2 HR. ASSEMBLY: UL U4112 LAYERS OF 5/8" TYPE "X"GYP. BD. ON EA. SIDE OF MTL.STUD FRAMING @ 16" O.C.(REF. PLAN FOR SIZE)

    G3.2

    6 Sim

    G3.2

    7 Sim

    HE

    IGH

    T V

    AR

    IES

    - R

    EF

    . RC

    P

    SOUND BATT INSUL.2'-0" WIDE EACH SIDE OFINTERIOR PARTITIONS EXCEPTWHERE PARTITION IS EXTENDEDTODECK.

    FLOOR SLAB OR ROOF DECKASSEMBLY

    EXTEND DRYWALL FIRERATEDOR SOUND PARTITION TODECK. WHERE SHOWN ONCODE SUMMARY PLAN.

    PROVIDE CMU BOND BM.CONT. ALONG TOP OF WALLW/ 2-#5 BARS CONT. -FILL SOLID W/ GROUT

    CEILING ASSCHED.

    HORIZ. REINF. @16" O.C. VERT. - CONT. HORIZ.

    CMU - REF. FLOORPLAN FOR SIZE

    BASE AS SCHED.

    FLOORING AS SCHED.

    CONC. SLAB - REF.STRUCT.

    EXTEND PARTITION AMIN. OF ONE BLOCKCOURSE ABOVE CLG.

    FIRERATED

    PARTITION

    SOUNDPARTITIO

    N

    IF INDICATED AS ASOUND WALL FILL WITHFOAMED IN PLACEINSULATION.

    TYP. CMU PARTITION STOPSONE COURSE ABOVEFINISHED CEILING IF NOTFIRE OR SOUND RATED

    REFER TO CODE SUMMARY PLANFOR LOCATIONS

    DRYWALL EXTENSION OF FIRE RATED OR SOUND PARTITIONS TO DECK

    G3.2

    6 Sim

    G3.2

    7 Sim

    G3.2

    5 Sim

    STL.BRACING AS

    REQ'D. - REF.STRUCT.

    HE

    IGH

    T V

    AR

    IES

    - R

    EF

    . RC

    P

    1"

    SOUND BATT INSUL.2'-0" WIDE EACH SIDE OFINTERIOR PARTITIONS EXCEPTWHERE PARTITION IS EXTENDED TODECK.

    FLOOR SLAB OR ROOF DECKASSEMBLY

    CEILING AS SCHED.

    HORIZ. REINF. @16" O.C. VERT. - CONT.HORIZ.CMU - REF. FLOORPLAN FOR SIZE

    BASE AS SCHED.

    FLOORING AS SCHED.

    CONC. SLAB - REF.STRUCT.

    FIRERATED

    PARTITION

    IF INDICATED AS ASOUND WALL FILL WITHFOAMED IN PLACEINSULATION.

    REFER TO CODE SUMMARY PLANFOR LOCATIONS

    EXTEND MASONRY FIRERATED

    PARTITION TO DECK WHERESHOWN ON CODE SUMMARY

    PLAN.

    PROVIDE CMU BOND BM.CONT. ALONG TOP OF WALL

    W/ 2-#5 BARS CONT. -FILL SOLID W/ GROUT

    STL. BRACING AS REQ'D. -REF. STRUCT.

    G3.2

    8 Sim

    REF. PLAN

    2 1/

    2"

    3/16"

    1/2"

    WHERE REQUIRED FOR FIRE WALL,PROVIDE 1 LAYER 5/8" TYPE "X"

    GYP. BD. ON EA. SIDE OF MTL.STUD FRAMING @ 16" O.C. @ 1

    HR. RATED (UL-U465) - PROVIDE2 LAYERS @ 2 HR. RATED

    (UL-U411) - FIRE TAPE AND BEDALL JOINTS @ FIRE WALL - EXTEND

    TO DECK PER DETAILMIN. 1/2" THICKNESS INTUMESCENTFIRESTOP SEALANT @ FIREPARTITIONON EA. SIDE. ACOUSTICAL SEALANTEA. SIDE @ SOUND PARTITION.

    SOUND BATT. INSUL.FULL HEIGHT OF WALL

    FIRE OR ACOUSTICALSEALANTALL GYP. BD. PENETRATIONS

    20 GA. STUD TRACK IFDRYWALL PARTITIONABOVE

    REF. STRUCT. FORWALL BRACING

    2-1/2"x2-1/2"x25 GA.RESTRAINING ANGLES EACH SIDE.ATTACH TO DECK AT 12" O.C.MAX. DO NOT SCREW TODEFLECTION TRACK OR WALLPARTITION.LINE RESTRAINING ANGLES WITHSAME WALLBOARD USED FORWALL. ATTACH TO ANGLE AT 8" O.C.MAX.

    MIN. 1/2" THICKINTUMESCENT FIRESTOP

    SEALANT ON EA. SIDE

    1-1/2" (MIN THICK) MINERALWOOL (MIN. 4PCF DENSITY)

    FIRMLY PACKED INTO FLUTES

    2 LAYERS 5/8" GYP. BD.TYPE "X" @ 2 HR. RATED

    (UL-U411) OR 1 LAYER 5/8"GYP. BD. TYPE "X" @ 1 HR.

    RATED (UL-U465) - FIRETAPE AND BED ALL JOINTS

    MTL. STUD FRAMING @ 16"O.C. (REF. PLAN FOR SIZE)

    BOTTOM OF FLOORSLAB OR MTL. DECK

    DEFLECTION HEAD TRACK W/ 2"MIN. LEGS. DO NOT SCREW STUDSOR WALL BOARD TO DEFLECTIONTRACK.

    TOP OF STUD (BEYOND) 1"BELOW BOTTOM OF HEAD TRACK

    SOUND BATT INSUL.

    NOTE: FIRESTOP DETAIL VARIES DEPENDINGON WHERE PARTITION BUTTS UP TO BOTTOMOF METAL DECK.

    1 HR: UL# HW-D-0001; 2 HR: UL# HW-D-0002

    NOTE ACCEPTABLE ALTERNATE: INSTALL"FIRETRACK" DEFLECTION TRACK AND FIRESTOPSYSTEM, CONSISTENT WITHMANUFACTURERS DETAILS FOR THE FIRERATING REQUIRED.

    1"

    2 1/

    2"

    1"

    FILL ALL FLUTES W/SOUND BATTS

    MTL. STUD FRAMING @ 16"O.C. (REF. PLAN FOR SIZE)

    BOTTOM OF FLOORSLAB OR MTL. DECK

    DEFLECTION HEAD TRACK W/ 2"MIN. LEGS. DO NOT SCREW STUDSOR WALL BOARD TO DEFLECTIONTRACK.

    TOP OF STUD (BEYOND) 1"BELOW BOTTOM OF HEAD TRACK

    SOUND BATT INSUL.FULL HEIGHT OF PARTITIONREF. PLAN

    1"

    FIRE SEALANT SYSTEM -REF. CODE PLAN FOR UL#

    1-1/2" (MIN THICK) MINERALWOOL (MIN. 4PCF DENSITY)

    FIRMLY PACKED INTO FLUTES

    MASONRY WALL (REF. PLANFOR SIZE)

    BOTTOM OF FLOORSLAB OR MTL. DECK

    1 HR: UL# HW-D-0040

    LINE RESTRAINING ANGLESWITHSAME WALLBOARD USED FORWALL. ATTACH TO ANGLE AT 8"O.C. MAX.

    MIN. 1/2" THICKINTUMESCENT FIRESTOP

    SEALANT ON EA. SIDE

    1-1/2" (MIN THICK) MINERALWOOL (MIN. 4PCF DENSITY)

    FIRMLY PACKED INTO FLUTES

    2 LAYERS 5/8" GYP. BD.TYPE "X" @ 2 HR. RATED

    (UL-U411) OR 1 LAYER5/8"

    GYP. BD. TYPE "X" @ 1HR.

    RATED (UL-U465) - FIRETAPE AND BED ALL

    JOINTSMTL. STUD FRAMING @ 16"O.C. (REF. PLAN FOR SIZE)

    BOTTOM OF FLOORSLAB OR MTL. DECK

    DEFLECTION HEAD TRACK W/ 2"MIN. LEGS. DO NOT SCREW STUDSOR WALL BOARD TO DEFLECTIONTRACK.

    TOP OF STUD (BEYOND) 1"BELOW BOTTOM OF HEAD TRACK

    SOUND BATT INSUL.

    NON COMBUSTIBLE BLOCKINGOR LONGER LEG FORRESTRAINING ANGLE

    ATTACHMENT TO DECK.

    1 HR: UL# HW-D-0001; 2 HR: UL# HW-D-0002

    NOTE ACCEPTABLE ALTERNATE: INSTALL"FIRETRACK" DEFLECTION TRACK AND FIRESTOPSYSTEM, CONSISTENT WITHMANUFACTURERS DETAILS FOR THE FIRERATING REQUIRED.

    2 1/

    2"

    1"ACOUSTICALSEALANT

    EACH SIDE.

    MTL. STUD FRAMING @ 16"O.C. (REF. PLAN FOR SIZE)

    BOTTOM OF FLOORSLAB OR MTL. DECK

    DEFLECTION HEAD TRACK W/ 2"MIN. LEGS. DO NOT SCREW STUDSOR WALL BOARD TO DEFLECTIONTRACK.

    TOP OF STUD (BEYOND) 1"BELOW BOTTOM OF HEAD TRACK

    SOUND BATT INSUL.FULL HEIGHT OF PARTITION

    1"

    REF. PLAN

    FIRE SEALANT SYSTEM -REF. CODE PLAN FOR UL#

    1-1/2" (MIN THICK) MINERALWOOL (MIN. 4PCF DENSITY)

    FIRMLY PACKED INTO FLUTES

    BOTTOM OF FLOORSLAB OR MTL. DECK

    MASONRY WALL (REF. PLANFOR SIZE)

    PROVIDE IDENTICAL JOINT INDRYWALL FURRING ONMASONRY.

    5/8" GYP. BD. ON EASIDE OF 3-5/8" MTLSTUDS @ 16" O.C.(TYPICAL) 2 LAYERSGYP BD. (AT 2 HOURWALLS)

    METAL C.J.EA. SIDE- CONT. VERT.

    NON-RATEDJT

    RATED JT -USG #WHI-647-3024

    AIRSPACE

    VARI

    ES

    1/4"

    MASONRY WALL

    SOUND BATT INSUL. ASSPEC. (U.N.O. ON PLAN.)

    5/8" GYP. BD. ON EA.SIDE OF MTL STUDS

    MTL STUDS @ 16"O.C.

    2- MTL STUDSCONT. VERT. REF.PLAN FOR STUDTHICKNESS.

    "Z" REVEAL MOLDING

    "Z" REVEAL MOLDING

    PROVIDE FILLER BEHINDBASE (BELOW) EA. SIDE.PAINT FILLER TO MATCHBASE COLOR.

    1/2"

    REF

    PLAN

    RE

    F. P

    LAN

    RAKE JOINT BACK 1/2" - PROVIDEBACKER ROD AND CONT. SEALANT - (CONT. VERT.)

    CMU

    REF. STRUCT. FORREINF. ANDGROUTINGREQUIREMENTS.

    RE

    F. P

    LAN

    REF. PLAN

    RAKE BACK JOINT 1/2" PROVIDEBACKER ROD AND CONT.SEALANT. (CONT. VERT.)

    EXPANDED METAL LATH 12"LONG @ 16" O.C. VERT.

    CMUREF. STRUCT. FOR REINF.AND GROUTING

    REQUIREMENTS.

    VERT. GREASE DUCT

    5/8" GYP BD ON 2 1/2" C-H STUDS W/ 1" GYP BD @INTERIOR TO MEET U.L. #U469 1 HR ASSEMBLY. EXTENDFROM TOP OF EXHAUST HOOD UP TO ROOF DECK, SEALALL JOINTS W/ FIRE SEALANT

    MIN4"

    MIN4"

    MIN

    4"

    MIN

    4"

    Sheet No.Job No.

    Drawn By:

    Date:

    Pro

    ject

    :

    Copyright © 2018, Huckabee & Associates, Inc.

    VOLUMEPACKAGE

    C:\

    Use

    rs\e

    torr

    es\D

    ocu

    men

    ts\1

    743-

    15-0

    1_D

    on

    ald

    ES

    Ren

    ova

    tio

    n -

    AR

    CH

    _v16

    _eto

    rres

    .rvt

    2/12

    /201

    8 2:

    43:1

    8 P

    M

    JMA

    G3.2

    TYPICAL INTERIOR

    PARTITION BRACING

    DETAILS

    2/12/2018

    1743-15-01

    DO

    NA

    LD E

    LEM

    EN

    TAR

    Y S

    CH

    OO

    LS

    TEM

    RE

    NO

    VA

    TIO

    NFO

    RLE

    WIS

    VIL

    LE I.

    S.D

    .FL

    OW

    ER

    MO

    UN

    D, T

    EX

    AS

    1 1/2" = 1'-0"1TYP. SECTION @ INTERIOR DRYWALL PARTITION

    1 1/2" = 1'-0"2TYP. SECTION @ INTERIOR DRYWALL FIRE RATED OR SOUND PARTITION

    1 1/2" = 1'-0"3TYP. SECTION @ INTERIOR CMU PARTITION

    1 1/2" = 1'-0"4TYP. SECTION @ INTERIOR CMU FIRE RATED OR SOUND PARTITION

    3" = 1'-0"5DETAIL - CMU PARTITION

    3" = 1'-0"6FIRE RATED CONNECTION OF WALL PERPENDICULAR TO DECK

    3" = 1'-0"7SOUND PARTITION CONNECTION OF WALL PERPENDICULAR TO DECK

    3" = 1'-0"8FIRE RATED CONNECTION OF WALL PERPENDICULAR TO DECK

    3" = 1'-0"9G3_FIRE RATED CONNECTION OF WALL PARALLEL TO DECK_3"

    3" = 1'-0"10SOUND PARTITION CONNECTION OF WALL PARALLEL TO DECK

    3" = 1'-0"11FIRE RATED CONNECTION OF WALL PARALLEL TO DECK

    3" = 1'-0"13TYP C.J. @ DRYWALL

    3" = 1'-0"14TYP DETAIL OF STEEL STUD PARTITION TO CMU

    1 1/2" = 1'-0"15CONTROL JOINT @ CMU

    1 1/2" = 1'-0"16TYP CMU PARTITION INTERSECTION

    1 1/2" = 1'-0"12DETAIL - RATED DUCT ENCLOSURE

    Rev

    isio

    n /

    Dat

    e

    10-05-152-12-18

  • 10' MB

    W5

    W4 W4

    W4 W4

    M4

    F1

    M2

    C1M1

    W2W2

    NO SCOPETHIS AREA

    W1

    M4

    M2W2W1

    M3

    W6

    W7

    NO SCOPETHIS AREA

    M6

    C3

    C3

    C3

    PROTECT EXISTING CARPET INLIBRARY DURING DEMOLITION ANDNEW CONSTRION

    V.I.F.

    +/- 7' - 2"

    V.I.F.+/- 1' - 9 1/4"

    12' - 2 3/4"

    V.I.F.

    +/- 7' - 2"

    V.I.F.+/- 1' - 9 1/4"

    12' - 3 3/4"

    V.I.F.+/- 2' - 1 1/2"

    6' - 1 1/2"

    DEMOLITION GENERAL NOTES

    A. BIDDERS TO VISIT SITE AND BE FAMILIAR WITH EXISTINGCONDITIONS, INCLUDING BUT NOT LIMITED TO EXISTINGDIMENSIONS, EQUIPMENT, LOCATIONS, SIZES, QUANTITIES,AND MATERIALS.

    B. EXISTING ELECTRICAL POWER SERVING THE EXISTINGFACILITY WILL REMAIN ON LINE. DISRUPTIONS REQUIREDFOR CONSTRUCTION TO BE COORDINATED WITH THESCHOOL DISTRICT REPRESENTATIVE ASSIGNED TO THISSPECIFIC PROJECT.

    C. EXISTING DRAIN LINES SERVING THE EXISTING FACILITYWILL REMAIN FUNCTIONAL. ANY DISRUPTIONS REQUIREDFOR NEW TIE-INS DURING CONSTRUCTION MUST BECOORDINATED WITH THE SCHOOL DISTRICTREPRESENTATIVE ASSIGNED TO THIS SPECIFIC PROJECT.

    D. CONTRACTOR WILL COORDINATE EXACT SIZES ANDLOCATIONS FOR MECHANICAL, PLUMBING, AND ELECTRICALPENETRATIONS REQUIRED FOR NEW WORK WITH EACHRESPECTIVE TRADE.

    E. CONTRACTOR WILL KEEP OPENINGS TO THE EXTERIORTEMPORARILY COVERED FOR PROTECTION FROM WATER.

    F. CONTRACTOR WILL KEEP OPENINGS TEMPORARILYCOVERED FOR PEDESTRIAN SAFETY.

    G. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN ANDINSTALLATION OF TEMPORARY SHORING AND BRACINGREQUIRED FOR DEMOLITION.

    H. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBINGSHEETS FOR ADDITIONAL PENETRATIONS AND OTHERRELATED DEMOLITION OR EQUIPMENT REMOVAL.

    I. EXISTING CONSTRUCTION IS SHOWN BASED UPON OWNERFURNISHED PLANS, OWNER FURNISHED SURVEYS, ANDONSITE OBSERVATIONS. DISCREPANCIES BETWEENDRAWINGS AND ACTUAL FIELD CONDITIONS WILL BEREPORTED TO THE ARCHITECT/ENGINEER/PROJECTMANAGER PRIOR TO PROCEEDING WITH WORK.

    J. EXISTING CONSTRUCTION ADJACENT TO DEMOLITIONWORK WILL BE PATCHED AND REPAIRED TO MATCHORIGINAL CONDITION.

    K. DEMOLITION WORK SCHEDULE SHALL BE COORDINATEDWITH THE SCHOOL DISTRICT REPRESENTATIVE ASSIGNEDTO THIS SPECIFIC PROJECT.

    L. THIS EXISTING FACILITY WILL REMAIN FUNCTIONALDURING THE COURSE OF THE DEMOLITION WORK.CONTRACTOR WILL MAINTAIN DUST BARRIERS,BARRICADES, PEDESTRIAN PROTECTION, WATERPROTECTION, AND SAFETY DEVICES IN PLACE AT ALL TIMESDURING AND AFTER DEMOLITION UNTIL NEW WORK ISINSTALLED.

    M. CONTRACTOR WILL MAINTAIN SITE DRAINAGE DEVICESAND COMPONENTS DURING THE COURSE OF DEMOLITIONAND UP UNTIL NEW WORK IS IN PLACE. THIS INCLUDESEXISTING SUB-SOIL DRAINAGE.

    N. REFER TO PROJECT SPECIFICATIONS FOR ADDITIONALREQUIREMENTS.

    O. REFER TO MECHANICAL, ELECTRICAL, AND ROOF PLANDRAWINGS FOR ADDITIONAL DEMOLITION NOT SPECIFICALLYCOVERED BY DEMOLITION PLANS, ESPECIALLY RELATIVE TOMODIFICATIONS TO EXISTING H.V.A.C. SYSTEMS.

    P. DEMOLITION, AS NOTED, CONSISTS OF COMPLETEREMOVAL OF THE LISTED ITEMS, RELATED FASTENERS, ANDATTACHMENT MATERIALS LEAVING A CLEAN SURFACEREADY TO RECEIVE NOTED MATERIALS OR SCHEDULEDFINISHES.

    Q. UNLESS NOTED OTHERWISE, MATERIALS WILL BEREMOVED FROM SITE AND DISPOSED OF AT CONTRACTOR'SEXPENSE, DISPOSAL WILL COMPLY WITH APPLICABLELOCAL, STATE, AND FEDERAL GUIDELINES.

    R. DEMOLITION WILL FOLLOW THE CONSTRUCTIONSCHEDULE PROVIDED IN THE SPECIFICATIONS.

    S. PRECAUTIONS WILL BE TAKEN TO SEPARATE STUDENTSAND SCHOOL STAFF FROM DEMOLITION AND TO PROECTTHEIR HEALTH AND SAFETY.

    T. ADDITIONAL MATERIALS, WHERE CONSTRUCTION ADJOINSEXISTING, NOT SPECIFICALLY IDENTIFIED IN THEDEMOLITION PLANS, WILL BE REMOVED AS REQUIRED TOCOMPLETE THE CONSTRUCTION. THESE MATERIALSTYPICALLY INCLUDE MATERIAL PROJECTION BEYOND THEFACE OF THE WALL, INCLUDING BRICK SILLS, OTHERPROJECTIONS, AND ROOF FLASHINGS, GUTTERS, ANDTRIMS. REFER TO WALL SECTIONS FOR SPECIFICCONDITIONS.

    U. INVESTIGATE EACH WALL SUBJECT TO DEMOLITION TODETERMINE IF IT IS USED FOR BEARING. COORDINATE WITHCONSTRUCTION SEQUENCE AND PROVIDE SHORING AT ANYWALL CARRYING STRUCTURAL LOAD TO PREVENT COLLAPSEUNTIL NEW STRUCTURE IS IN PLACE.

    V. OWNER RESERVES FIRST RIGHT TO RETAIN AND KEEPANY EXISTING ITEMS REMOVED AS A PART OF THEDEMOLITION WORK.

    W. GENERAL CONTRACTOR SHALL COORDINATE THEREMOVAL OF ALL TECHNOLOGY AND COMMUNICATIONDEVICES INCLUDING INTERCOM SPEAKERS, CLOCKS,WIRELESS ACCESS POINTS, CAFETERIA SPEAKERS,PROJECTORS, PROJECTOR PLATES, AUDIO-VIDEO CABLING,INTELLIGENT BOARDS, SCREENS, ETC WITH THE SOUND,INTERCOM AND TECHNOLOGY CONTRACTORS. THIS WORKMUST BE DONE PRIOR TO REMOVAL OF CEILING TILE OROTHER CEILING AND PLENUM WORK.

    X. ALL TECHNOLOGY AND LOW-VOLTAGE CABLING IN THEPLENUM SHALL REMAIN IN PLACE. ANY DAMAGE TO THISCABLING SHALL HAVE NEW CABLING PLACED BY THEPROPER TRADE CONTRACTOR AT THE SOLE EXPENSE OFTHE CONTRACTOR THAT DAMAGED THE CABLING. ALLCABLES HAVE BEEN TESTED PRIOR TO RENOVATION WORKAND ALL WILL BE TESTED AFTER THE WORK IS COMPLETED.

    EXISTING PARTITION TO BE REMOVED. INCLUDINGBASE, DOORS, WINDOWS, OUTLETS, SWITCHES,CHALK/TACK BOARDS, POWER POLES, WALL CAPSAND ANY ITEM ATTACHED TO OR ASSOCIATEDWITH THE PARTITION. CONTRACTOR WILL VERIFYELECTRICAL, MECHANICAL & PLUMBING INEXISTING WALLS & TERMINATE OR RELOCATE ASREQUIRED FOR CONTRACT WORK. PATCH,REPAIR & CLEAN ALL ADJACENT WALLS ANDPREPARE TO RECEIVE NEW PARTITION WALLS ASSHOWN ON FLOOR PLANS.

    EXISTING DOOR AND FRAME TO BE REMOVEDUNLESS OTHERWISE NOTED.

    EXISTING ITEM TO BE REMOVED AS NOTED.

    EXISTING WALL / PARTITION TO REMAIN.

    EXISTING DOOR AND FRAME TO REMAIN.

    DEMOLITION LEGEND

    NOTES BY SYMBOL

    DOORS & WINDOWS

    D1. REMOVE & DISPOSE OF EXISTING DOOR & FRAME.

    MISCELLANEOUS

    M1. REMOVE & DISPOSE OF EXISTING MILLWORK, CABINETS AND/ORSHELVING. PATCH AND REPAIR ADJACENT WALL FINISHES.REMOVEALL ASSOCIATED EXISTING ELECTRICAL POWER IFPRESENT AND TERMINATE AT WALL OR FLOOR W/ BLANK FACEPLATE OR JUNCTION BOX THAT CAN BE COVERED.

    M2. REMOVE EXISTING DISPLAY CASE. SAWCUT OPENING INMASONRY WALL BEYOND FOR INSTALLATION OF NEW STEEL LINTELIF BRICK IS PRESENT AND WINDOW FRAME.

    M3. REMOVE EXISTING METAL LOCKERS AND SALVAGE BACK TOOWNER.

    M4. EXISTINGMILLWORK, CABINETS AND/OR SHELVING TO REMAIN INPLACE.

    M5. REMOVE EXISTING MARKER BOARD AND SALVAGE BACK TOOWNER.

    M6. REMOVE EXISTING TACK BOARDS AND SALVAGE BACK TOOWNER.

    CEILINGS

    C1. REMOVE EXISTING CEILING GRID, ACOUSTICAL CEILING TILE,GRILLES, DIFFUSERS, LIGHTING, AND ALL OTHER ITEMSOCCURRING WITHIN THE CEILING PLANE IN THIS AREA FORINSTALLATION OF NEW CEILING AND LIGHTING. STORE ANDPROTECT OTHER ITEMS FOR REINSTALLATION. PREPAREADJACENT WALLS TO RECEIVE NEW CEILING AS SHOWN ONREFLECTED CEILING PLANS.

    C2. RECONFIGURE EXISTING CEILING GRID, ACOUSTICAL CEILINGTILE, GRILLES, DIFFUSERS, LIGHTING, AND ALL OTHER ITEMSOCCURING WITHIN THE CEILING PLANE AS REQUIRED FORREMOVAL OF EXISTING WALL PARTITIONS TO CREATE LARGERCLASSROOM.

    C3. PROTECT EXISTING GYP BD BULKHEAD IN PLACE DURINGDEMOLITION FOR RE-USE IN NEW CONSTRUCTION.

    FLOORS

    F1. REMOVE EXISTING CARPETED FLOORING & BASE DOWN TOEXISTING SUBSTRATE. REMOVE EXISTING BUILT-UP CONCRETEFLOOR SLAB AND STEPPED CONCRETE PLATFORMS DOWN TOEXISTING FINISHED CONCRETE FLOOR SLAB. PATCH & REPAIREXIST SUBSTRATE, APPLY LEVELING COMPOUND AS REQ'D FORNEW SCHEDULED FINISH.

    WALLS

    W1. EXISTING INTERIOR PLASTIC LAMINATE WALL PANELINGALONG CORRIDOR SIDE OF WALL TO BE MODIFIED AS REQUIREDFOR NEW DISPLAY CASES OR WINDOW. PROTECT DURINGDEMOLITION AND NEW CONSTRUCTION.

    W2. SHORE, BRACE, AND CUT OPENING INTO EXISTING WALL.PREPARE OPENING TO RECEIVE NEW WINDOW FRAME AND/ORNEW DOOR FRAME AND HARDWARE AS SCHEDULED.

    W3. REMOVE EXISTING WALL PARTITION (SHOWN DASHED,TYPICAL) IN ITS ENTIRITY, INCLUDING BASE, DOORS, WINDOWS,OUTLETS, SWITCHES, AND ANY ITEM ATTACHED TO ORASSOCIATED WITH THE WALL PARTITION. CONTRACTOR SHALLVERIFY ELECTRICAL, MECHANICAL AND PLUMBING IN EXISTINGWALLS AND TERMINATE OR RELOCATE AS REQUIRED FORCONTRACT WORK. PATCH, REPAIR AND CLEAN ALL ADJACENTSURFACES TO RECIEVE NEW FINISHES AS SCHEDULED ON PLANS.

    W4. REMOVE EXISTING WINDOWS AND WALL BELOW BETWEENGYP BRD FURRED COLUMNS AND BELOW GYP BRD BULK HEAD.CONTRACTOR SHALL VERIFY ELECTRICAL IN EXISTING WALLS ANDTERMINATE OR RELOCATE AS REQUIRED FOR CONTRACT WORK.PATCH, REPAIR AND CLEAN ADJACENT WALLS TO RECEIVE NEWWALLS OR CASEWORK AS SHOWN ON PLANS.

    W5. REMOVE PARTIAL HEIGHT PORTION OF WOOD CAPPED, CMUMASONRY WALL TO FLOOR SLAB. PATCH, REPAIR AND CLEANADJACENT SURFACES AND STEEL SUPPORT COLUMNSTO LEAVECLEAN OPENING FOR INSTALLATION OF NEW ALUMINUMSTOREFRONT AS SHOWN ON PLANS.

    W6. PREP EXISTING WALL WITH SUPER-HIDE PRIMER FOR NEWPAINTED FINISH AND/OR NEW GRAPHICS.

    W7. EXISTING STUDENT STORE TO BE RENOVATED BYALLOWANCE.

    Sheet No.Job No.

    Drawn By:

    Date:

    Pro

    ject

    :

    Copyright © 2018, Huckabee & Associates, Inc.

    VOLUMEPACKAGE

    C:\

    Use

    rs\e

    torr

    es\D

    ocu

    men

    ts\1

    743-

    15-0

    1_D

    on

    ald

    ES

    Ren

    ova

    tio

    n -

    AR

    CH

    _v16

    _eto

    rres

    .rvt

    2/12

    /201

    8 2:

    43:1

    0 P

    M

    Author

    AD1.1

    DEMOLITION FLOOR PLAN -

    SECTION 2

    2/12/2018

    1743-15-01

    DO

    NA

    LD E

    LEM

    EN

    TAR

    Y S

    CH

    OO

    LS

    TEM

    RE

    NO

    VA

    TIO

    NFO

    RLE

    WIS

    VIL

    LE I.

    S.D

    .FL

    OW

    ER

    MO

    UN

    D, T

    EX

    AS

    4

    3

    2

    1

    KEY PLAN - 1ST FLOOR

    N.T.S.

    NPLAN

    1/8" = 1'-0"1DEMOLITION PLAN - SECTION 2

    Rev

    isio

    n /

    Dat

    e

    10-05-152-12-18

  • 10' MB

    D1

    D1

    M3

    M1

    W3

    W3

    M3M4

    M4 M4

    M1

    M4

    M2W2W1 M5

    C2

    C2

    C2

    DEMOLITION GENERAL NOTES

    A. BIDDERS TO VISIT SITE AND BE FAMILIAR WITH EXISTINGCONDITIONS, INCLUDING BUT NOT LIMITED TO EXISTINGDIMENSIONS, EQUIPMENT, LOCATIONS, SIZES, QUANTITIES,AND MATERIALS.

    B. EXISTING ELECTRICAL POWER SERVING THE EXISTINGFACILITY WILL REMAIN ON LINE. DISRUPTIONS REQUIREDFOR CONSTRUCTION TO BE COORDINATED WITH THESCHOOL DISTRICT REPRESENTATIVE ASSIGNED TO THISSPECIFIC PROJECT.

    C. EXISTING DRAIN LINES SERVING THE EXISTING FACILITYWILL REMAIN FUNCTIONAL. ANY DISRUPTIONS REQUIREDFOR NEW TIE-INS DURING CONSTRUCTION MUST BECOORDINATED WITH THE SCHOOL DISTRICTREPRESENTATIVE ASSIGNED TO THIS SPECIFIC PROJECT.

    D. CONTRACTOR WILL COORDINATE EXACT SIZES ANDLOCATIONS FOR MECHANICAL, PLUMBING, AND ELECTRICALPENETRATIONS REQUIRED FOR NEW WORK WITH EACHRESPECTIVE TRADE.

    E. CONTRACTOR WILL KEEP OPENINGS TO THE EXTERIORTEMPORARILY COVERED FOR PROTECTION FROM WATER.

    F. CONTRACTOR WILL KEEP OPENINGS TEMPORARILYCOVERED FOR PEDESTRIAN SAFETY.

    G. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN ANDINSTALLATION OF TEMPORARY SHORING AND BRACINGREQUIRED FOR DEMOLITION.

    H. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBINGSHEETS FOR ADDITIONAL PENETRATIONS AND OTHERRELATED DEMOLITION OR EQUIPMENT REMOVAL.

    I. EXISTING CONSTRUCTION IS SHOWN BASED UPON OWNERFURNISHED PLANS, OWNER FURNISHED SURVEYS, ANDONSITE OBSERVATIONS. DISCREPANCIES BETWEENDRAWINGS AND ACTUAL FIELD CONDITIONS WILL BEREPORTED TO THE ARCHITECT/ENGINEER/PROJECTMANAGER PRIOR TO PROCEEDING WITH WORK.

    J. EXISTING CONSTRUCTION ADJACENT TO DEMOLITIONWORK WILL BE PATCHED AND REPAIRED TO MATCHORIGINAL CONDITION.

    K. DEMOLITION WORK SCHEDULE SHALL BE COORDINATEDWITH THE SCHOOL DISTRICT REPRESENTATIVE ASSIGNEDTO THIS SPECIFIC PROJECT.

    L. THIS EXISTING FACILITY WILL REMAIN FUNCTIONALDURING THE COURSE OF THE DEMOLITION WORK.CONTRACTOR WILL MAINTAIN DUST BARRIERS,BARRICADES, PEDESTRIAN PROTECTION, WATERPROTECTION, AND SAFETY DEVICES IN PLACE AT ALL TIMESDURING AND AFTER DEMOLITION UNTIL NEW WORK ISINSTALLED.

    M. CONTRACTOR WILL MAINTAIN SITE DRAINAGE DEVICESAND COMPONENTS DURING THE COURSE OF DEMOLITIONAND UP UNTIL NEW WORK IS IN PLACE. THIS INCLUDESEXISTING SUB-SOIL DRAINAGE.

    N. REFER TO PROJECT SPECIFICATIONS FOR ADDITIONALREQUIREMENTS.

    O. REFER TO MECHANICAL, ELECTRICAL, AND ROOF PLANDRAWINGS FOR ADDITIONAL DEMOLITION NOT SPECIFICALLYCOVERED BY DEMOLITION PLANS, ESPECIALLY RELATIVE TOMODIFICATIONS TO EXISTING H.V.A.C. SYSTEMS.

    P. DEMOLITION, AS NOTED, CONSISTS OF COMPLETEREMOVAL OF THE LISTED ITEMS, RELATED FASTENERS, ANDATTACHMENT MATERIALS LEAVING A CLEAN SURFACEREADY TO RECEIVE NOTED MATERIALS OR SCHEDULEDFINISHES.

    Q. UNLESS NOTED OTHERWISE, MATERIALS WILL BEREMOVED FROM SITE AND DISPOSED OF AT CONTRACTOR'SEXPENSE, DISPOSAL WILL COMPLY WITH APPLICABLELOCAL, STATE, AND FEDERAL GUIDELINES.

    R. DEMOLITION WILL FOLLOW THE CONSTRUCTIONSCHEDULE PROVIDED IN THE SPECIFICATIONS.

    S. PRECAUTIONS WILL BE TAKEN TO SEPARATE STUDENTSAND SCHOOL STAFF FROM DEMOLITION AND TO PROECTTHEIR HEALTH AND SAFETY.

    T. ADDITIONAL MATERIALS, WHERE CONSTRUCTION ADJOINSEXISTING, NOT SPECIFICALLY IDENTIFIED IN THEDEMOLITION PLANS, WILL BE REMOVED AS REQUIRED TOCOMPLETE THE CONSTRUCTION. THESE MATERIALSTYPICALLY INCLUDE MATERIAL PROJECTION BEYOND THEFACE OF THE WALL, INCLUDING BRICK SILLS, OTHERPROJECTIONS, AND ROOF FLASHINGS, GUTTERS, ANDTRIMS. REFER TO WALL SECTIONS FOR SPECIFICCONDITIONS.

    U. INVESTIGATE EACH WALL SUBJECT TO DEMOLITION TODETERMINE IF IT IS USED FOR BEARING. COORDINATE WITHCONSTRUCTION SEQUENCE AND PROVIDE SHORING AT ANYWALL CARRYING STRUCTURAL LOAD TO PREVENT COLLAPSEUNTIL NEW STRUCTURE IS IN PLACE.

    V. OWNER RESERVES FIRST RIGHT TO RETAIN AND KEEPANY EXISTING ITEMS REMOVED AS A PART OF THEDEMOLITION WORK.

    W. GENERAL CONTRACTOR SHALL COORDINATE THEREMOVAL OF ALL TECHNOLOGY AND COMMUNICATIONDEVICES INCLUDING INTERCOM SPEAKERS, CLOCKS,WIRELESS ACCESS POINTS, CAFETERIA SPEAKERS,PROJECTORS, PROJECTOR PLATES, AUDIO-VIDEO CABLING,INTELLIGENT BOARDS, SCREENS, ETC WITH THE SOUND,INTERCOM AND TECHNOLOGY CONTRACTORS. THIS WORKMUST BE DONE PRIOR TO REMOVAL OF CEILING TILE OROTHER CEILING AND PLENUM WORK.

    X. ALL TECHNOLOGY AND LOW-VOLTAGE CABLING IN THEPLENUM SHALL REMAIN IN PLACE. ANY DAMAGE TO THISCABLING SHALL HAVE NEW CABLING PLACED BY THEPROPER TRADE CONTRACTOR AT THE SOLE EXPENSE OFTHE CONTRACTOR THAT DAMAGED THE CABLING. ALLCABLES HAVE BEEN TESTED PRIOR TO RENOVATION WORKAND ALL WILL BE TESTED AFTER THE WORK IS COMPLETED.

    EXISTING PARTITION TO BE REMOVED. INCLUDINGBASE, DOORS, WINDOWS, OUTLETS, SWITCHES,CHALK/TACK BOARDS, POWER POLES, WALL CAPSAND ANY ITEM ATTACHED TO OR ASSOCIATEDWITH THE PARTITION. CONTRACTOR WILL VERIFYELECTRICAL, MECHANICAL & PLUMBING INEXISTING WALLS & TERMINATE OR RELOCATE ASREQUIRED FOR CONTRACT WORK. PATCH,REPAIR & CLEAN ALL ADJACENT WALLS ANDPREPARE TO RECEIVE NEW PARTITION WALLS ASSHOWN ON FLOOR PLANS.

    EXISTING DOOR AND FRAME TO BE REMOVEDUNLESS OTHERWISE NOTED.

    EXISTING ITEM TO BE REMOVED AS NOTED.

    EXISTING WALL / PARTITION TO REMAIN.

    EXISTING DOOR AND FRAME TO REMAIN.

    DEMOLITION LEGEND

    NOTES BY SYMBOL

    DOORS & WINDOWS

    D1. REMOVE & DISPOSE OF EXISTING DOOR & FRAME.

    MISCELLANEOUS

    M1. REMOVE & DISPOSE OF EXISTING MILLWORK, CABINETS AND/ORSHELVING. PATCH AND REPAIR ADJACENT WALL FINISHES.REMOVEALL ASSOCIATED EXISTING ELECTRICAL POWER IFPRESENT AND TERMINATE AT WALL OR FLOOR W/ BLANK FACEPLATE OR JUNCTION BOX THAT CAN BE COVERED.

    M2. REMOVE EXISTING DISPLAY CASE. SAWCUT OPENING INMASONRY WALL BEYOND FOR INSTALLATION OF NEW STEEL LINTELIF BRICK IS PRESENT AND WINDOW FRAME.

    M3. REMOVE EXISTING METAL LOCKERS AND SALVAGE BACK TOOWNER.

    M4. EXISTINGMILLWORK, CABINETS AND/OR SHELVING TO REMAIN INPLACE.

    M5. REMOVE EXISTING MARKER BOARD AND SALVAGE BACK TOOWNER.

    M6. REMOVE EXISTING TACK BOARDS AND SALVAGE BACK TOOWNER.

    CEILINGS

    C1. REMOVE EXISTING CEILING GRID, ACOUSTICAL CEILING TILE,GRILLES, DIFFUSERS, LIGHTING, AND ALL OTHER ITEMSOCCURRING WITHIN THE CEILING PLANE IN THIS AREA FORINSTALLATION OF NEW CEILING AND LIGHTING. STORE ANDPROTECT OTHER ITEMS FOR REINSTALLATION. PREPAREADJACENT WALLS TO RECEIVE NEW CEILING AS SHOWN ONREFLECTED CEILING PLANS.

    C2. RECONFIGURE EXISTING CEILING GRID, ACOUSTICAL CEILINGTILE, GRILLES, DIFFUSERS, LIGHTING, AND ALL OTHER ITEMSOCCURING WITHIN THE CEILING PLANE AS REQUIRED FORREMOVAL OF EXISTING WALL PARTITIONS TO CREATE LARGERCLASSROOM.

    C3. PROTECT EXISTING GYP BD BULKHEAD IN PLACE DURINGDEMOLITION FOR RE-USE IN NEW CONSTRUCTION.

    FLOORS

    F1. REMOVE EXISTING CARPETED FLOORING & BASE DOWN TOEXISTING SUBSTRATE. REMOVE EXISTING BUILT-UP CONCRETEFLOOR SLAB AND STEPPED CONCRETE PLATFORMS DOWN TOEXISTING FINISHED CONCRETE FLOOR SLAB. PATCH & REPAIREXIST SUBSTRATE, APPLY LEVELING COMPOUND AS REQ'D FORNEW SCHEDULED FINISH.

    WALLS

    W1. EXISTING INTERIOR PLASTIC LAMINATE WALL PANELINGALONG CORRIDOR SIDE OF WALL TO BE MODIFIED AS REQUIREDFOR NEW DISPLAY CASES OR WINDOW. PROTECT DURINGDEMOLITION AND NEW CONSTRUCTION.

    W2. SHORE, BRACE, AND CUT OPENING INTO EXISTING WALL.PREPARE OPENING TO RECEIVE NEW WINDOW FRAME AND/ORNEW DOOR FRAME AND HARDWARE AS SCHEDULED.

    W3. REMOVE EXISTING WALL PARTITION (SHOWN DASHED,TYPICAL) IN ITS ENTIRITY, INCLUDING BASE, DOORS, WINDOWS,OUTLETS, SWITCHES, AND ANY ITEM ATTACHED TO ORASSOCIATED WITH THE WALL PARTITION. CONTRACTOR SHALLVERIFY ELECTRICAL, MECHANICAL AND PLUMBING IN EXISTINGWALLS AND TERMINATE OR RELOCATE AS REQUIRED FORCONTRACT WORK. PATCH, REPAIR AND CLEAN ALL ADJACENTSURFACES TO RECIEVE NEW FINISHES AS SCHEDULED ON PLANS.

    W4. REMOVE EXISTING WINDOWS AND WALL BELOW BETWEENGYP BRD FURRED COLUMNS AND BELOW GYP BRD BULK HEAD.CONTRACTOR SHALL VERIFY ELECTRICAL IN EXISTING WALLS ANDTERMINATE OR RELOCATE AS REQUIRED FOR CONTRACT WORK.PATCH, REPAIR AND CLEAN ADJACENT WALLS TO RECEIVE NEWWALLS OR CASEWORK AS SHOWN ON PLANS.

    W5. REMOVE PARTIAL HEIGHT PORTION OF WOOD CAPPED, CMUMASONRY WALL TO FLOOR SLAB. PATCH, REPAIR AND CLEANADJACENT SURFACES AND STEEL SUPPORT COLUMNSTO LEAVECLEAN OPENING FOR INSTALLATION OF NEW ALUMINUMSTOREFRONT AS SHOWN ON PLANS.

    W6. PREP EXISTING WALL WITH SUPER-HIDE PRIMER FOR NEWPAINTED FINISH AND/OR NEW GRAPHICS.

    W7. EXISTING STUDENT STORE TO BE RENOVATED BYALLOWANCE.

    Sheet No.Job No.

    Drawn By:

    Date:

    Pro

    ject

    :

    Copyright © 2018, Huckabee & Associates, Inc.

    VOLUMEPACKAGE

    C:\

    Use

    rs\e

    torr

    es\D

    ocu

    men

    ts\1

    743-

    15-0

    1_D

    on

    ald

    ES

    Ren

    ova

    tio

    n -

    AR

    CH

    _v16

    _eto

    rres

    .rvt

    2/12

    /201

    8 2:

    55:0

    3 P

    M

    Author

    AD1.2

    DEMOLITION FLOOR PLAN -

    SECTION 3

    2/12/2018

    1743-15-01

    DO

    NA

    LD E

    LEM

    EN

    TAR

    Y S

    CH

    OO

    LS

    TEM

    RE

    NO

    VA

    TIO

    NFO

    RLE

    WIS

    VIL

    LE I.

    S.D

    .FL

    OW

    ER

    MO

    UN

    D, T

    EX

    AS

    4

    3

    2

    1

    KEY PLAN - 1ST FLOOR

    N.T.S.

    NPLAN

    1/8" = 1'-0"1DEMOLITION PLAN - SECTION 3

    Rev

    isio

    n /

    Dat

    e

    10-05-152-12-18

  • 10' MB

    10' MB4' TB 4' TB

    8' TB 8' MB

    MASTER FLOOR PLAN AND PLAN SECTIONS

    THE MASTER FLOOR PLAN SHOWS THE OVERALL BUILDINGCONFIGURATION AND THE RELATIONSHIP OF THE SECTION PLANSWHICH FOLLOW. REFER TO LARGER SCALE PLANS AND PLANDETAILS FOR ADDITIONAL INFORMATION AND CONSTRUCTIONREQUIREMENTS. MASTER PLAN LEGENDS ALSO APPLY TO 1/8"SCALE FLOOR PLAN SECTIONS.

    COMPUTER

    325

    CLASSROOM

    CLASSROOM

    TOILET

    TOILET

    CLASSROOM

    CLASSROOM

    CLASSROOM

    KILN

    CLASSROOM

    319CLASSROOM

    CLASSROOM

    CLASSROOM

    STORAGEMECH

    GIRLS

    BOYS

    TOILET

    CLASSROOMCLASSROOMCLASSROOMCLASSROOM

    CLASSROOM CLASSROOMCLASSROOM

    303 CLASSROOM

    OFFICE

    STOR

    MAKER

    219

    LIBRARY

    215

    STORAGE

    OFFICE

    STORAGE

    CLASSROOMCLASSROOMCLASSROOMCLASSROOMCLASSROOM

    CLASSROOM CLASSROOM CLASSROOM CLASSROOM

    BOYS

    GIRLS

    ELECBOOK STORAGE

    CLASSROOM

    CLASSROOM

    CLASSROOM

    STOR

    TOILET

    TOILET

    STOR STOR

    TOILET

    TOILET

    STOR

    CLASSROOM

    CLASSROOM

    CLASSROOM

    CLASSROOM

    CLASSROOM

    ENTRY

    VEST

    STOROFFICE

    OFFICE

    WORK ROOM

    RECORDS

    GEN. OFFICE

    NURSE

    TOILET

    TOILET

    TOILETSTORAGE

    STORAGE

    FACULTY

    WORK ROOM

    STOR

    ELEC

    BOYS

    JANITOR

    GIRLS

    KITCHEN

    LAUNDRY

    ELEC

    LOCKER

    STORAGE

    W/H

    JANITOR

    OFFICE/STORAGE

    VEST

    VEST

    STORAGESPRINKLER

    ELEC

    CENTRAL JANITOR

    STORAGE

    MUSIC

    STORAGEOFFICETOILETTOILET

    GYM

    DIAG

    OFFICE

    VEST

    CORRIDOR

    STORAGE

    OFFICE

    TEST

    STORAGEVEST

    STAGE

    CAFETERIA

    VEST

    STORAGE

    COMMONS

    CORRIDOR

    CORRIDOR

    VEST

    TOILET

    CORRIDOR

    JAN

    CORRIDORCORRIDOR

    CORRIDOR

    CORRIDOR

    VEST

    STORAGE JANITOR

    CLASSROOMCLASSROOM

    CLASSROOM

    CLASSROOMCLASSROOMCLASSROOM

    CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM

    BOYSGIRLS

    TOILETJANITOR

    VEST

    RESOURCERESOURCECLASSROOM

    ELEC/RISER

    CLASSROOMCLASSROOM

    CORRIDOR

    STORAGE

    STORAGE

    COMMONS

    COMMONS

    COMMONS

    MECH

    STAIR

    RESOURCE

    3

    42

    1

    CLASSROOM

    100

    READING NOOK

    215A

    RESOURCE

    Sheet No.Job No.

    Drawn By:

    Date:

    Pro

    ject

    :

    Copyright © 2018, Huckabee & Associates, Inc.

    VOLUMEPACKAGE

    C:\

    Use

    rs\e

    torr

    es\D

    ocu

    men

    ts\1

    743-

    15-0

    1_D

    on

    ald

    ES

    Ren

    ova

    tio

    n -

    AR

    CH

    _v16

    _eto

    rres

    .rvt

    2/12

    /201

    8 2:

    42:3

    2 P

    M

    Author

    A1.1

    MASTER PLAN

    2/12/2018

    1743-15-01

    DO

    NA

    LD E

    LEM

    EN

    TAR

    Y S

    CH

    OO

    LS

    TEM

    RE

    NO

    VA

    TIO

    NFO

    RLE

    WIS

    VIL

    LE I.

    S.D

    .FL

    OW

    ER

    MO

    UN

    D, T

    EX

    AS

    4

    3

    2

    1

    KEY PLAN - 1ST FLOOR

    N.T.S.

    NPLAN

    1/16" = 1'-0"1MASTER PLAN - LEVEL 1

    Rev

    isio

    n /

    Dat

    e

    10-05-152-12-18

  • HCLAV

    HC

    LAV

    WC

    WC WC WC

    U UHCU

    HCLAV

    A8.11

    21

    A3.1

    DR/

    WND

    HM-A

    A4.1

    1

    A4.12

    9

    A8.2

    Sim9

    A8.2

    SimM4 M4

    CLASSROOM

    100

    CORRIDOR

    112

    CORRIDOR

    110

    NOT IN SCOPE OF WORK

    NOT IN SCOPE OF WORK

    NOT IN SCOPE OF WORK

    HM-A HM-A

    CORRIDOR

    134

    PARTITION TYPE TAGSA3

    LETTER INDICATES PARTITION TYPE.

    NUMBER INDICATES STUD OR CMU SIZE AS FOLLOWS: 1 - 7/8" HAT CHANNEL 6 - 6" MTL STUD OR 5 5/8" CMU 2 - 1 5/8" MTL STUD 8 - 8" MTL STUD OR 7 5/8" CMU 3 - 2 1/2" MTL STUD 12 - 11 5/8" CMU 4 - 3 5/8" MTL STUD OR CMU 16 - DOUBLE 7 5/8" CMU

    WALL ASSEMBLY IN PLAN VIEW

    REF. TYP. CONST. DTLS. FOR ADDITIONAL INFO.

    PARTITION LEGEND

    GENERAL FLOOR PLAN NOTES

    NOTES:

    1) THE CONTRACT DOCUMENTS ARE COMPRISED OF BOTH THEDRAWINGS AND THE SPECIFICATIONS.

    2) ALL DIMENSIONS SHOWN ARE TO FACE OF GYP. BD., MASONRYOR CONCRETE.

    3) SEE DETAIL DRAWINGS FOR ADDITIONAL REINFORCEMENTREQUIREMENTS.

    4) SEE SPECIFICATIONS AND TYPICAL CONSTRUCTION DETAILSFOR ADDITIONAL MASONRY AND DRYWALL REQUIREMENTS.

    5) SEE PLUMBING PLANS AND ENLARGED FLOOR PLANS FOR EXACTLOCATIONS OF FIXTURES.

    6) REF. DOOR AND WINDOW DETAILS FOR MASONRY ROUGHOPENING SIZES.

    7) PROVIDE WD BLOCKING IN ALL GYP BD WALLS AS REQ'D ATLOCATIONS INCLUDING BUT NOT LIMITED TO; HANDRAILS, TOILETACCESSORIES, PROJECTORS, CASEWORK, TACK BD'S, MARKERBD'S, WALL STOPS & DOOR HOLDERS.

    8) REF. A2 SHEET FOR PARTIAL REFLECTED CEILING PLAN.

    9) ALL BULKHEADS SHALL BE PAINTED PNT02 U.N.O.

    NEW DRYWALL PARTITION

    EXISTING DRYWALL PARTITION

    PARTITION TYPE TAG SHAPES

    REF. G3 SHEETS FOR PARTITION TYPE ASSEMBLIES.

    A3

    NOTES:1) ALL UNTAGGED DRYWALL PARTITIONS ARE TO BE ASSUMED TYPEH4. WHERE TUBE STEEL COLUMN IS BEING ENCASED, PARTITIONSARE TO BE TYPE H6. COLUMN FURRINGS ARE TO BE TYPE M4 NON-ACOUSTICAL. THESE "STANDARD" PARTITIONS ARE TO EXTEND 6"ABOVE CEILING.

    2) THE INSIDE OF DRYWALL CHASES NEED NOT BE GYP BD UNLESSTHAT PORTION OF THE CHASE IS PART OF A FIRE-RATED ASSEMBLY.

    WALL TO 6" ABOVE CEILING

    FIRE EXTINGUISHER - REF SPEC SECT. 10 4400.PROVIDE TYPE "K" @ KITCHEN AREAS

    PROJECTION SCREENREF. TYP. DET. ON A8 SHEETS

    MARKERBOARDREF. TYP. DET. ON A8 SHEETS

    TACKBOARDREF. TYP. DET. ON A8 SHEETS

    ELECTRIC WATER COOLER - REF PLUMBING PLAN.

    DOOR ASSEMBLY NUMBER - REF. SCHEDULE ON A3SHTS. FOR DESCRIPTION.

    WINDOW ASSEMBLY NUMBER - REF. SCHEDULE ON A3SHTS. FOR DESCRIPTION.

    SPECIAL OPENING NUMBER (ROLLING DOOR) - REF.SCHEDULE ON A3 SHTS. FOR DESCRIPTION.

    ELEVATION REFERENCE

    CALLOUT REFERENCE

    WALL SECTION REFERENCE

    STRUCTURAL STEEL COLUMN - REF. STRUCT.DRAWINGS.

    FLOOR PLAN LEGEND

    RD-1

    APPLIES TO SECTIONPLANS

    F.E.C.

    A1.1 1

    1

    A101

    SIM

    X' M.B.

    P.S.

    X' T.B.

    1

    A1.1

    1.01

    1.01

    PNT- PAINT

    FINISH KEY

    X Y

    MATERIAL TYPE

    # #

    FINISH COLOR ANDMATERIAL SIZE AS NOTEDIN SPEC. SECTION 01 6210

    REFER TO PROJECT SPECIFICATIONS SECTION 01 6210 FORADDITIONAL INFORMATION REGARDING FINISH MATERIALS ANDPAINT FINISH CODES.

    NOTES:

    GENERAL FINISH NOTES

    1) PAINT ALL CLASSROOM CORRIDOR WALLS FROM TOP OFDOOR FRAME AND EXISTING PLASTIC LAMINATE WALL PANELSTO CEILING.

    2) PAINT CAFETERIA AND GYM WALLS AS INDICATED ONINTERIOR ELEVATIONS.

    3) PAINT "STEM" GRAPHIC WALLS AS INDICATED ON INTERIORELEVATIONS AND COORDINATED WITH SCHOOL PRINCIPAL.

    4) EXISTING ACOUSTICAL LAY-IN CEILINGS AND LIGHTING TOREMAIN IN PLACE U.N.O.

    5) EXISTING FLOORING AND BASE TO REMAIN IN PLACE U.N.O.

    9) ALL BULKHEADS SHALL BE PAINTED PNT02 U.N.O.

    Sheet No.Job No.

    Drawn By:

    Date:

    Pro

    ject

    :

    Copyright © 2018, Huckabee & Associates, Inc.

    VOLUMEPACKAGE

    C:\

    Use

    rs\e

    torr

    es\D

    ocu

    men

    ts\1

    743-

    15-0

    1_D

    on

    ald

    ES

    Ren

    ova

    tio

    n -

    AR

    CH

    _v16

    _eto

    rres

    .rvt

    2/12

    /201

    8 2:

    42:3

    6 P

    M

    LM; BS

    A1.2

    FLOOR PLAN - SECTION 1

    2/12/2018

    1743-15-01

    DO

    NA

    LD E

    LEM

    EN

    TAR

    Y S

    CH

    OO

    LS

    TEM

    RE

    NO

    VA

    TIO

    NFO

    RLE

    WIS

    VIL

    LE I.

    S.D

    .FL

    OW

    ER

    MO

    UN

    D, T

    EX

    AS

    Rev

    isio

    n /

    Dat

    e

    4

    3

    2

    1

    KEY PLAN - 1ST FLOOR

    N.T.S.

    1/8" = 1'-0"1FLOOR PLAN - SECTION 1

    A4 - ROOM FINISH SCHEDULE - SECTION 1

    ROOM

    FLOOR FINISH BASE

    WALL FINISH

    COMMENTSNUMBER NAME N FINISH E FINISH S FINISH W FINISH

    100 CLASSROOM EXIST EXIST PNT01 PNT01 PNT01 PNT01

    110 CORRIDOR EXIST EXIST PNT01 PNT01 PNT01 PNT01

    112 CORRIDOR EXIST EXIST PNT01 PNT01 PNT01 PNT01

    134 CORRIDOR EXIST EXIST PNT01 PNT01 PNT01 PNT01

    10-05-152-12-18

  • HCLAV HC

    LAV

    HC

    LAV

    WC

    WC

    WC

    WC

    WC

    HC U

    UU

    A8.2

    1

    A8.2

    2

    A8.2

    5

    A8.2

    4

    A4.1 19

    20

    21

    18

    9

    A8.2

    Sim

    9

    A8.2

    Sim

    LIBRARY

    215

    CORRIDOR

    211

    COMMONS

    212

    COMMONS

    213

    COMMONS

    214

    A4.1 911

    7

    10

    A4.1

    16

    17

    NOT IN SCOPE OF WORK

    NOT IN SCOPE OF WORK

    NOT IN SCOPE OF WORK

    A4.1

    8

    SF-A

    SF-B

    SF-B

    READING NOOK

    215A

    MAKER

    219

    FIN FLOOR

    100' - 0"

    FIN FLOOR

    97' - 8"

    FIN FLOOR

    100' - 0"

    FIN FLOOR

    97' - 8"

    RAMP DN

    FIN FLOOR

    97' - 8"

    FIN FLOOR

    100' - 0"

    RA

    MP

    DN

    RA

    MP

    DN

    UP

    DNPAINT HAND-RAILS PNT 03

    PAINT HAND-RAILS PNT 03

    PAINT EXIST.HANDRAILS &GUARDRAILS- PNT03

    EXISTING CIRCULATIONDESK - REPAIR CHIPPEDOR MISSING PLASTICLAMINATE

    A4.1 13

    12

    A4.1

    15

    14

    PAINT HAND-RAILS - PNT03

    HM-AHM-A

    HM-A HM-A

    9

    A8.2

    Sim

    8 7/8" 6' - 0"

    5 1/8"

    1' - 9 1/4" 1' - 9 3/8"4' - 0" 8" 4' - 0"

    1' - 9 3/8"

    1' - 9 3/8"

    4' - 0"

    8"

    4' - 0"

    1' - 9 1/2" 1' - 9 1/4"

    5 7/8" 6' - 0"

    INDICATESEXTENTS OFPNT04

    CT01; TO MATCHEXISTING

    PNT02 AT SIDEWALLS

    M4

    M4

    9 1/8" 6' - 0"

    4 7/8"

    PNT02 AT SIDEWALLS

    PARTITION TYPE TAGS A3

    LETTER INDICATES PARTITION TYPE.

    NUMBER INDICATES STUD OR CMU SIZE AS FOLLOWS: 1 - 7/8" HAT CHANNEL 6 - 6" MTL STUD OR 5 5/8" CMU 2 - 1 5/8" MTL STUD 8 - 8" MTL STUD OR 7 5/8" CMU 3 - 2 1/2" MTL STUD 12 - 11 5/8" CMU 4 - 3 5/8" MTL STUD OR CMU 16 - DOUBLE 7 5/8" CMU

    WALL ASSEMBLY IN PLAN VIEW

    REF. TYP. CONST. DTLS. FOR ADDITIONAL INFO.

    PARTITION LEGEND

    GENERAL FLOOR PLAN NOTES

    NOTES:

    1) THE CONTRACT DOCUMENTS ARE COMPRISED OF BOTH THEDRAWINGS AND THE SPECIFICATIONS.

    2) ALL DIMENSIONS SHOWN ARE TO FACE OF GYP. BD., MASONRYOR CONCRETE.

    3) SEE DETAIL DRAWINGS FOR ADDITIONAL REINFORCEMENTREQUIREMENTS.

    4) SEE SPECIFICATIONS AND TYPICAL CONSTRUCTION DETAILSFOR ADDITIONAL MASONRY AND DRYWALL REQUIREMENTS.

    5) SEE PLUMBING PLANS AND ENLARGED FLOOR PLANS FOR EXACTLOCATIONS OF FIXTURES.

    6) REF. DOOR AND WINDOW DETAILS FOR MASONRY ROUGHOPENING SIZES.

    7) PROVIDE WD BLOCKING IN ALL GYP BD WALLS AS REQ'D ATLOCATIONS INCLUDING BUT NOT LIMITED TO; HANDRAILS, TOILETACCESSORIES, PROJECTORS, CASEWORK, TACK BD'S, MARKERBD'S, WALL STOPS & DOOR HOLDERS.

    8) REF. A2 SHEET FOR PARTIAL REFLECTED CEILING PLAN.

    9) ALL BULKHEADS SHALL BE PAINTED PNT02 U.N.O.

    NEW DRYWALL PARTITION

    EXISTING DRYWALL PARTITION

    PARTITION TYPE TAG SHAPES

    REF. G3 SHEETS FOR PARTITION TYPE ASSEMBLIES.

    A3

    NOTES:1) ALL UNTAGGED DRYWALL PARTITIONS ARE TO BE ASSUMED TYPEH4. WHERE TUBE STEEL COLUMN IS BEING ENCASED, PARTITIONSARE TO BE TYPE H6. COLUMN FURRINGS ARE TO BE TYPE M4 NON-ACOUSTICAL. THESE "STANDARD" PARTITIONS ARE TO EXTEND 6"ABOVE CEILING.

    2) THE INSIDE OF DRYWALL CHASES NEED NOT BE GYP BD UNLESSTHAT PORTION OF THE CHASE IS PART OF A FIRE-RATED ASSEMBLY.

    WALL TO 6" ABOVE CEILING

    FIRE EXTINGUISHER - REF SPEC SECT. 10 4400.PROVIDE TYPE "K" @ KITCHEN AREAS

    PROJECTION SCREENREF. TYP. DET. ON A8 SHEETS

    MARKERBOARDREF. TYP. DET. ON A8 SHEETS

    TACKBOARDREF. TYP. DET. ON A8 SHEETS

    ELECTRIC WATER COOLER - REF PLUMBING PLAN.

    DOOR ASSEMBLY NUMBER - REF. SCHEDULE ON A3SHTS. FOR DESCRIPTION.

    WINDOW ASSEMBLY NUMBER - REF. SCHEDULE ON A3SHTS. FOR DESCRIPTION.

    SPECIAL OPENING NUMBER (ROLLING DOOR) - REF.SCHEDULE ON A3 SHTS. FOR DESCRIPTION.

    ELEVATION REFERENCE

    CALLOUT REFERENCE

    WALL SECTION REFERENCE

    STRUCTURAL STEEL COLUMN - REF. STRUCT.DRAWINGS.

    FLOOR PLAN LEGEND

    RD-1

    APPLIES TO SECTIONPLANS

    F.E.C.

    A1.1 1

    1

    A101

    SIM

    X' M.B.

    P.S.

    X' T.B.

    1

    A1.1

    1.01

    1.01

    NOTES:

    GENERAL FINISH NOTES

    1) PAINT ALL CLASSROOM CORRIDOR WALLS FROM TOP OFDOOR FRAME AND EXISTING PLASTIC LAMINATE WALL PANELSTO CEILING.

    2) PAINT CAFETERIA AND GYM WALLS AS INDICATED ONINTERIOR ELEVATIONS.

    3) PAINT "STEM" GRAPHIC WALLS AS INDICATED ON INTERIORELEVATIONS AND COORDINATED WITH SCHOOL PRINCIPAL.

    4) EXISTING ACOUSTICAL LAY-IN CEILINGS AND LIGHTING TOREMAIN IN PLACE U.N.O.

    5) EXISTING FLOORING AND BASE TO REMAIN IN PLACE U.N.O.

    9) ALL BULKHEADS SHALL BE PAINTED PNT02 U.N.O.

    Sheet No.Job No.

    Drawn By:

    Date:

    Pro

    ject

    :

    Copyright © 2018, Huckabee & Associates, Inc.

    VOLUMEPACKAGE

    C:\

    Use

    rs\e

    torr

    es\D

    ocu

    men

    ts\1

    743-

    15-0

    1_D

    on

    ald

    ES

    Ren

    ova

    tio

    n -

    AR

    CH

    _v16

    _eto

    rres

    .rvt

    2/12

    /201

    8 2:

    42:3

    9 P

    M

    Author

    A1.3

    FLOOR PLAN - SECTION 2

    2/12/2018

    1743-15-01

    DO

    NA

    LD E

    LEM

    EN

    TAR

    Y S

    CH

    OO

    LS

    TEM

    RE

    NO

    VA

    TIO

    NFO

    RLE

    WIS

    VIL

    LE I.

    S.D

    .FL

    OW

    ER

    MO

    UN

    D, T

    EX

    AS

    4

    3

    2

    1

    KEY PLAN - 1ST FLOOR

    N.T.S.

    NPLAN 1/8" = 1'-0"1

    FLOOR PLAN - SECTION 2

    Rev

    isio

    n /

    Dat

    e

    A4 - ROOM FINISH SCHEDULE - SECTION 2

    SECTION

    ROOM

    ALT FINISH FLOOR FINISH BASE

    WALL FINISH

    COMMENTSNUMBER NAME N FINISH E FINISH S FINISH W FINISH

    SECTION 2 211 CORRIDOR EXIST EXIST PNT01 PNT01 PNT01 PNT01

    SECTION 2 212 COMMONS EXIST EXIST PNT01 PNT01 PNT01 PNT01 1

    SECTION 2 213 COMMONS EXIST EXIST PNT01 PNT01 PNT01 PNT01 1

    SECTION 2 214 COMMONS EXIST EXIST PNT01 PNT01, 02 PNT01 PNT01 1

    SECTION 2 215 LIBRARY EXIST EXIST PNT01, 02 PNT01, 02, 04 PNT01, 02 PNT01, 02

    10-05-152-12-18

  • HCLAV

    HC

    LAV

    WC WC WC

    WC

    HCU

    U U

    FD

    WC

    WC

    10' MB

    10' MB4' TB 4' TB

    A8.1 3

    A8.1

    4

    5

    HM-A HM-A

    1

    A3.1

    Sim9

    A8.2

    Sim

    CLASSROOM

    319

    COMPUTER

    325

    CLASSROOM

    303

    CORRIDOR

    328

    CORRIDOR

    326

    CORRIDOR

    327

    A4.1

    1

    Sim

    A4.12

    Sim

    NOT IN SCOPE OF WORK

    NOT IN SCOPE OF WORK

    NOT IN SCOPE OF WORK

    NOT IN SCOPE OF WORK

    NOT IN SCOPE OF WORK

    INFILL EXISTINGWALL - 5/8" GYP BD.

    ON 3 5/8" C.F.M.F.STUDS @ 1'-4" O.C.

    (MAX)

    PARTITION TYPE TAGSA3

    LETTER INDICATES PARTITION TYPE.

    NUMBER INDICATES STUD OR CMU SIZE AS FOLLOWS: 1 - 7/8" HAT CHANNEL 6 - 6" MTL STUD OR 5 5/8" CMU 2 - 1 5/8" MTL STUD 8 - 8" MTL STUD OR 7 5/8" CMU 3 - 2 1/2" MTL STUD 12 - 11 5/8" CMU 4 - 3 5/8" MTL STUD OR CMU 16 - DOUBLE 7 5/8" CMU

    WALL ASSEMBLY IN PLAN VIEW

    REF. TYP. CONST. DTLS. FOR ADDITIONAL INFO.

    PARTITION LEGEND

    GENERAL FLOOR PLAN NOTES

    NOTES:

    1) THE CONTRACT DOCUMENTS ARE COMPRISED OF BOTH THEDRAWINGS AND THE SPECIFICATIONS.

    2) ALL DIMENSIONS SHOWN ARE TO FACE OF GYP. BD., MASONRYOR CONCRETE.

    3) SEE DETAIL DRAWINGS FOR ADDITIONAL REINFORCEMENTREQUIREMENTS.

    4) SEE SPECIFICATIONS AND TYPICAL CONSTRUCTION DETAILSFOR ADDITIONAL MASONRY AND DRYWALL REQUIREMENTS.

    5) SEE PLUMBING PLANS AND ENLARGED FLOOR PLANS FOR EXACTLOCATIONS OF FIXTURES.

    6) REF. DOOR AND WINDOW DETAILS FOR MASONRY ROUGHOPENING SIZES.

    7) PROVIDE WD BLOCKING IN ALL GYP BD WALLS AS REQ'D ATLOCATIONS INCLUDING BUT NOT LIMITED TO; HANDRAILS, TOILETACCESSORIES, PROJECTORS, CASEWORK, TACK BD'S, MARKERBD'S, WALL STOPS & DOOR HOLDERS.

    8) REF. A2 SHEET FOR PARTIAL REFLECTED CEILING PLAN.

    9) ALL BULKHEADS SHALL BE PAINTED PNT02 U.N.O.

    NEW DRYWALL PARTITION

    EXISTING DRYWALL PARTITION

    PARTITION TYPE TAG SHAPES

    REF. G3 SHEETS FOR PARTITION TYPE ASSEMBLIES.

    A3

    NOTES:1) ALL UNTAGGED DRYWALL PARTITIONS ARE TO BE ASSUMED TYPEH4. WHERE TUBE STEEL COLUMN IS BEING ENCASED, PARTITIONSARE TO BE TYPE H6. COLUMN FURRINGS ARE TO BE TYPE M4 NON-ACOUSTICAL. THESE "STANDARD" PARTITIONS ARE TO EXTEND 6"ABOVE CEILING.

    2) THE INSIDE OF DRYWALL CHASES NEED NOT BE GYP BD UNLESSTHAT PORTION OF THE CHASE IS PART OF A FIRE-RATED ASSEMBLY.

    WALL TO 6" ABOVE CEILING

    FIRE EXTINGUISHER - REF SPEC SECT. 10 4400.PROVIDE TYPE "K" @ KITCHEN AREAS

    PROJECTION SCREENREF. TYP. DET. ON A8 SHEETS

    MARKERBOARDREF. TYP. DET. ON A8 SHEETS

    TACKBOARDREF. TYP. DET. ON A8 SHEETS

    ELECTRIC WATER COOLER - REF PLUMBING PLAN.

    DOOR ASSEMBLY NUMBER - REF. SCHEDULE ON A3SHTS. FOR DESCRIPTION.

    WINDOW ASSEMBLY NUMBER - REF. SCHEDULE ON A3SHTS. FOR DESCRIPTION.

    SPECIAL OPENING NUMBER (ROLLING DOOR) - REF.SCHEDULE ON A3 SHTS. FOR DESCRIPTION.

    ELEVATION REFERENCE

    CALLOUT REFERENCE

    WALL SECTION REFERENCE

    STRUCTURAL STEEL COLUMN - REF. STRUCT.DRAWINGS.

    FLOOR PLAN LEGEND

    RD-1

    APPLIES TO SECTIONPLANS

    F.E.C.

    A1.1 1

    1

    A101

    SIM

    X' M.B.

    P.S.

    X' T.B.

    1

    A1.1

    1.01

    1.01

    NOTES:

    GENERAL FINISH NOTES

    1) PAINT ALL CLASSROOM CORRIDOR WALLS FROM TOP OFDOOR FRAME AND EXISTING PLASTIC LAMINATE WALL PANELSTO CEILING.

    2) PAINT CAFETERIA AND GYM WALLS AS INDICATED ONINTERIOR ELEVATIONS.

    3) PAINT "STEM" GRAPHIC WALLS AS INDICATED ON INTERIORELEVATIONS AND COORDINATED WITH SCHOOL PRINCIPAL.

    4) EXISTING ACOUSTICAL LAY-IN CEILINGS AND LIGHTING TOREMAIN IN PLACE U.N.O.

    5) EXISTING FLOORING AND BASE TO REMAIN IN PLACE U.N.O.

    9) ALL BULKHEADS SHALL BE PAINTED PNT02 U.N.O.

    Sheet No.Job No.

    Drawn By:

    Date:

    Pro

    ject

    :

    Copyright © 2018, Huckabee & Associates, Inc.

    VOLUMEPACKAGE

    C:\

    Use

    rs\e

    torr

    es\D

    ocu

    men

    ts\1

    743-

    15-0

    1_D

    on

    ald

    ES

    Ren

    ova

    tio

    n -

    AR

    CH

    _v16

    _eto

    rres

    .rvt

    2/12

    /201

    8 2:

    42:4

    5 P

    M

    Author

    A1.4

    FLOOR PLAN - SECTION 3

    2/12/2018

    1743-15-01

    DO

    NA

    LD E

    LEM

    EN

    TAR

    Y S

    CH

    OO

    LS

    TEM

    RE

    NO

    VA

    TIO

    NFO

    RLE

    WIS

    VIL

    LE I.

    S.D

    .FL

    OW

    ER

    MO

    UN

    D, T

    EX

    AS

    1/8" = 1'-0"1FLOOR PLAN - SECTION 3

    4

    3

    2

    1

    KEY PLAN - 1ST FLOOR

    N.T.S.

    NPLAN

    Rev

    isio

    n /

    Dat

    e

    A4 - ROOM FINISH SCHEDULE - SECTION 3

    SECTION

    ROOM

    ALT FINISH FLOOR FINISH BASE

    WALL FINISH

    COMMENTSNUMBER NAME N FINISH E FINISH S FINISH W FINISH

    SECTION 3 303 CLASSROOM EXIST EXIST EXIST EXIST EXIST EXIST

    SECTION 3 319 CLASSROOM EXIST EXIST EXIST EXIST EXIST EXIST

    SECTION 3 325 COMPUTER EXIST EXIST PNT01 EXIST EXIST EXIST

    SECTION 3 326 CORRIDOR EXIST EXIST PNT01 PNT01 PNT01 PNT01

    SECTION 3 327 CORRIDOR EXIST EXIST PNT01 PNT01 PNT01 PNT01

    SECTION 3 328 CORRIDOR EXIST EXIST PNT01 PNT01 PNT01 PNT01

    10-05-152-12-18

  • HC

    LAV

    HCLAV

    UU

    HC U

    WC

    WC

    WC

    WC

    8' TB 8' MB

    A4.1

    22

    23

    A4.1 46

    3

    5

    A4.1 911

    7

    10

    GYM

    447

    CORRIDOR

    439

    CAFETERIA

    401

    COMMONS

    432

    GEN. OFFICE

    422

    ENTRY

    433

    NOT IN SCOPE OF WORK

    NOT IN SCOPE OF WORK

    NOT IN SCOPE OF WORK

    A4.1

    8

    DR/

    WND

    SF-B

    A4.1

    12

    A4.1

    15

    14

    NOT IN SCOPE OF WORK

    PARTITION TYPE TAGSA3

    LETTER INDICATES PARTITION TYPE.

    NUMBER INDICATES STUD OR CMU SIZE AS FOLLOWS: 1 - 7/8" HAT CHANNEL 6 - 6" MTL STUD OR 5 5/8" CMU 2 - 1 5/8" MTL STUD 8 - 8" MTL STUD OR 7 5/8" CMU 3 - 2 1/2" MTL STUD 12 - 11 5/8" CMU 4 - 3 5/8" MTL STUD OR CMU 16 - DOUBLE 7 5/8" CMU

    WALL ASSEMBLY IN PLAN VIEW

    REF. TYP. CONST. DTLS. FOR ADDITIONAL INFO.

    PARTITION LEGEND

    GENERAL FLOOR PLAN NOTES

    NOTES:

    1) THE CONTRACT DOCUMENTS ARE COMPRISED OF BOTH THEDRAWINGS AND THE SPECIFICATIONS.

    2) ALL DIMENSIONS SHOWN ARE TO FACE OF GYP. BD., MASONRYOR CONCRETE.

    3) SEE DETAIL DRAWINGS FOR ADDITIONAL REINFORCEMENTREQUIREMENTS.

    4) SEE SPECIFICATIONS AND TYPICAL CONSTRUCTION DETAILSFOR ADDITIONAL MASONRY AND DRYWALL REQUIREMENTS.

    5) SEE PLUMBING PLANS AND ENLARGED FLOOR PLANS FOR EXACTLOCATIONS OF FIXTURES.

    6) REF. DOOR AND WINDOW DETAILS FOR MASONRY ROUGHOPENING SIZES.

    7) PROVIDE WD BLOCKING IN ALL GYP BD WALLS AS REQ'D ATLOCATIONS INCLUDING BUT NOT LIMITED TO; HANDRAILS, TOILETACCESSORIES, PROJECTORS, CASEWORK, TACK BD'S, MARKERBD'S, WALL STOPS & DOOR HOLDERS.

    8) REF. A2 SHEET FOR PARTIAL REFLECTED CEILING PLAN.

    9) ALL BULKHEADS SHALL BE PAINTED PNT02 U.N.O.

    NEW DRYWALL PARTITION

    EXISTING DRYWALL PARTITION

    PARTITION TYPE TAG SHAPES

    REF. G3 SHEETS FOR PARTITION TYPE ASSEMBLIES.

    A3

    NOTES:1) ALL UNTAGGED DRYWALL PARTITIONS ARE TO BE ASSUMED TYPEH4. WHERE TUBE STEEL COLUMN IS BEING ENCASED, PARTITIONSARE TO BE TYPE H6. COLUMN FURRINGS ARE TO BE TYPE M4 NON-ACOUSTICAL. THESE "STANDARD" PARTITIONS ARE TO EXTEND 6"ABOVE CEILING.

    2) THE INSIDE OF DRYWALL CHASES NEED NOT BE GYP BD UNLESSTHAT PORTION OF THE CHASE IS PART OF A FIRE-RATED ASSEMBLY.

    WALL TO 6" ABOVE CEILING

    FIRE EXTINGUISHER - REF SPEC SECT. 10 4400.PROVIDE TYPE "K" @ KITCHEN AREAS

    PROJECTION SCREENREF. TYP. DET. ON A8 SHEETS

    MARKERBOARDREF. TYP. DET. ON A8 SHEETS

    TACKBOARDREF. TYP. DET. ON A8 SHEETS

    ELECTRIC WATER COOLER - REF PLUMBING PLAN.

    DOOR ASSEMBLY NUMBER - REF. SCHEDULE ON A3SHTS. FOR DESCRIPTION.

    WINDOW ASSEMBLY NUMBER - REF. SCHEDULE ON A3SHTS. FOR DESCRIPTION.

    SPECIAL OPENING NUMBER (ROLLING DOOR) - REF.SCHEDULE ON A3 SHTS. FOR DESCRIPTION.

    ELEVATION REFERENCE

    CALLOUT REFERENCE

    WALL SECTION REFERENCE

    STRUCTURAL STEEL COLUMN - REF. STRUCT.DRAWINGS.

    FLOOR PLAN LEGEND

    RD-1

    APPLIES TO SECTIONPLANS

    F.E.C.

    A1.1 1

    1

    A101

    SIM

    X' M.B.

    P.S.

    X' T.B.

    1

    A1.1

    1.01

    1.01

    PNT- PAINT

    FINISH KEY

    X Y

    MATERIAL TYPE

    # #

    FINISH COLOR ANDMATERIAL SIZE AS NOTEDIN SPEC. SECTION 01 6210

    REFER TO PROJECT SPECIFICATIONS SECTION 01 6210 FORADDITIONAL INFORMATION REGARDING FINISH MATERIALS ANDPAINT FINISH CODES.

    NOTES:

    GENERAL FINISH NOTES

    1) PAINT ALL CLASSROOM CORRIDOR WALLS FROM TOP OFDOOR FRAME AND EXISTING PLASTIC LAMINATE WALL PANELSTO CEILING.

    2) PAINT CAFETERIA AND GYM WALLS AS INDICATED ONINTERIOR ELEVATIONS.

    3) PAINT "STEM" GRAPHIC WALLS AS INDICATED ON INTERIORELEVATIONS AND COORDINATED WITH SCHOOL PRINCIPAL.

    4) EXISTING ACOUSTICAL LAY-IN CEILINGS AND LIGHTING TOREMAIN IN PLACE U.N.O.

    5) EXISTING FLOORING AND BASE TO REMAIN IN PLACE U.N.O.

    9) ALL BULKHEADS SHALL BE PAINTED PNT02 U.N.O.

    Sheet No.Job No.

    Drawn By:

    Date:

    Pro

    ject

    :

    Copyright © 2018, Huckabee & Associates, Inc.

    VOLUMEPACKAGE

    C:\

    Use

    rs\e

    torr

    es\D

    ocu

    men

    ts\1

    743-

    15-0

    1_D

    on

    ald

    ES

    Ren

    ova

    tio

    n -

    AR

    CH

    _v16

    _eto

    rres

    .rvt

    2/12

    /201

    8 2:

    42:4

    9 P

    M

    LM

    A1.5

    FLOOR PLAN - SECTION 4

    2/12/2018

    1743-15-01

    DO

    NA

    LD E

    LEM

    EN

    TAR

    Y S

    CH

    OO

    LS

    TEM

    RE

    NO

    VA

    TIO

    NFO

    RLE

    WIS

    VIL

    LE I.

    S.D

    .FL

    OW

    ER

    MO

    UN

    D, T

    EX

    AS

    Rev

    isio

    n /

    Dat

    e

    1/8" = 1'-0"1FLOOR PLAN - SECTION 4

    4

    3

    2

    1

    KEY PLAN - 1ST FLOOR

    N.T.S.

    A4 - ROOM FINISH SCHEDULE - SECTION 4

    SECTION

    ROOM

    ALT FINISH FLOOR FINISH BASE

    WALL FINISH

    COMMENTSNUMBER NAME N FINISH E FINISH S FINISH W FINISH

    SECTION 4 401 CAFETERIA EXIST EXIST PNT01, 02 PNT01, 02 PNT01, 02 PNT01, 02

    SECTION 4 422 GEN. OFFICE EXIST EXIST PNT01 PNT02 PNT01 PNT01

    SECTION 4 432 COMMONS EXIST EXIST PNT01, 02 PNT01, 02 PNT01, 02 PNT01, 02

    SECTION 4 439 CORRIDOR EXIST EXIST PNT01 PNT01 PNT01 PNT01

    SECTION 4 447 GYM EXIST EXIST PNT01, 02 PNT01, 02 PNT01, 02 PNT01, 02

    10-05-152-12-18

  • CEILING FINISH LEGEND

    REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL INFORMATIONREGARDING FINISH MATERIALS AND PAINT FINISH CODES.

    CEILING

    ESF - EXPOSED DECK AND STRUCTURE (FINISHED)

    GYP - SUSPENDED 5/8" GYPSUM BOARD

    L1 - TYPE I 2' x 2' LAY-IN SUSPENDED CEILING TILE(STANDARD CEILING)

    WDS - SUSPENDED WOOD CEILING

    CEILING TYPE

    REFLECTED CEILING LEGEND

    CX

    9'-0"

    LAY-IN CEILING AS SCHED.

    SUSPENDED GYPSUM BOARD CEILING WITH CONTROLJOINTS AS SPEC. FINISH AS SCHED.

    SUSPENDED WOOD VERTICAL BLADE CEILING WITHWIDE SPACED DOWELED BLADES ON SUSPENSION GRID

    METAL SOFFIT PANELS

    LIGHT FIXTURES, SPEAKER - REF. ELECTRICALDRAWINGS.

    PROJECTION SCREEN - REF. TYP. FINISH DETAILS.

    HVAC GRILLE, DIFFUSER - REF. MECHANICALDRAWINGS.

    1) COORDINATE REFLECTED CEILING PLANS WITH MECHANICAL ANDELECTRICAL DRAWINGS TO AVOID CONFLICTS. VERIFY EXACTMOUNTING LOCATIONS OF ALL CEILING-MOUNTED EQUIPMENTPRIOR TO INSTALLATION. CONTRACTOR SHALL ASSUMERESPONSIBILITY FOR VERIFYING ALL ITEMS AND EQUIPMENT INCEILING.

    2) PERIMETER WALLS OF ALL SPACES WITH EXPOSED STRUCTURESHALL EXTEND TO BOTTOM OF ROOF DECK. FINISH EXPOSEDSTRUCTURE AS SCHED.

    3) REFER TO FINISH SCHEDULE FOR UNIFORM CEILING HEIGHTS.AREAS WITH VARYING FINISHES AND HEIGHTS ARE SHOWN ONREFLECTED CEILING PLAN.

    4) AT IDFs AND MDFs, CEILING AND GRID SHALL BE HELD OFF OFDISTRIBUTION WALL 6" TO ACCOMMODATE CABLING.

    5) PROVIDE 2'x2' ACCESS PANEL(S) IN ALL HARD CEILINGS FORMAINTENANCE OF EQUIPMENT.

    REFLECTED CEILING PLAN GENERAL NOTES

    CEILING HEIGHT

    IF ANY ROOM IS NOT IDENTIFIED BY A ROOM FINISH TAG, THEFOLLOWING FINISHES SHALL BE USED AS "TYPICAL" OR "DEFAULT"FINISHES FOR BIDDING PURPOSES. VERIFY FINISHES WITHARCHITECT BEFORE INSTALLATION.

    CEILING - L1CEILING HEIGHT - 109'-0" (9'-0" A.F.F.)

    DEFAULT FINISHES

    GENERAL NOTES - ALL BULKHEADS, PLASTER AND GYP. CEILINGS1. ALL BULKHEADS SHALL BE CONSTRUCTED OF 5/8" GYP. BD. ON 3-5/8" MTL. STUDS AT 1'-4" O.C. U.NO.2. FINISH ALL BULKHEADS TO CODE 115, U.N.O.3. PROVIDE CONTROL JOINTS (CJ) IN BULKHEADS AT 10'-0" O.C. OR AS SHOWN ON PLAN AND AS SPEC.4. ALL SECTION PROFILES SHOWN IN THIS SCHEDULE SHALL BE DETAILED AS SHOWN UNDER TYPICAL DETAILS.5. PROVIDE BRACING IN ALL BULKHEADS @ 4' - 0" O.C.6. PROVIDE CONTROL JOINT (CJ) IN ALL PLASTER CLGS., SOFFITS AT MAX. 10'-0" OR AS SHOWN ON PLAN AND AS SPEC.7. PROVIDE STOP CONT. WHERE PLASTER SOFFIT MEETS VERTICAL SURFACE AND CAULK CONT.

    TYPICAL BULKHEAD

    DETAILS

    TYPICAL BULKHEAD PROFILES

    N.T.S.

    DETAIL 'A' DETAIL 'B'

    2"M

    IN.

    SUSPENDED CEILING

    CEILING TRIM

    3 FASTENERS

    5/8" GYP. BD. ON 3 5/8"MTL. STUDS - EXTENDSTUD TO STRUCT. ABOVE

    SEALANT JOINT CONT.

    METAL 'J' TRIM

    STAGGERFASTENERS @1'-4" O.C.

    DET. 'B' - SIM. DET. 'B'

    DET. 'A'

    REVEAL

    REVEAL

    5/8" GYP BD ON 3-5/8" MTL STUDEXTEND UP&ATTACH TOSTRUCT ABOVE

    3 FASTENERSMIN

    CEILING TRIMREVEAL INSTALLPER MANUF.INSTRUCTIONS

    NOTE: WHERE GYP CEILING ANDLAY-IN CEILING TILES ARESCHEDULED TO BE AT THESAME HEIGHT A.F.F., ADRYWALL ACOUSTICAL REVEALSHALL BE USED AS SPECIFIED.

    3/4" 1"

    1/2"

    DETAIL 'C'

    METAL 'J' TRIM

    5/8" GYP BD

    TRANSITION CLIP

    GYP BD SUSPSYSTEM

    CORNER BEAD

    6"

    TYP SUSP CLOUD EDGE DETAIL

    N.T.S.

    /2

    A2.

    1

    WDS

    9' - 0"

    EXISTING

    EXISTING

    EXISTING

    EXISTING

    EXISTING

    EXISTING

    EXISTING

    EXISTING

    EXISTING

    EXISTING

    EXISTING

    EXISTING

    PROTECT EXISTING GYP BDBULKHEAD IN PLACE DURINGDEMOLITION FOR RE-USE INNEW CONSTRUCTION. PNT02

    /2

    A2.1

    NOT IN SCOPE OF WORK

    EXIST. WALLTO REMAIN

    SUSPENDED WOODCEILING AS SCHED.

    NOTE: REF. RCP FORCEILING HEIGHTS

    3/4" REVEAL

    DOWEL (BEYOND)

    GYP SUSP SYSTEM GRID

    HANGING WIRE

    DOWEL CLIP

    SAFETY WIRE

    METAL WALLANGLE ANDFASTENER

    Sheet No.Job No.

    Drawn By:

    Date:

    Pro

    ject

    :

    Copyright © 2018, Huckabee & Associates, Inc.

    VOLUMEPACKAGE

    C:\

    Use

    rs\e

    torr

    es\D

    ocu

    men

    ts\1

    743-

    15-0

    1_D

    on

    ald

    ES

    Ren

    ova

    tio

    n -

    AR

    CH

    _v16

    _eto

    rres

    .rvt

    2/12

    /201

    8 2:

    42:5

    1 P

    M

    ET, JH

    A2.1

    REFLECTED CEILING PLAN -

    SECTION 2

    2/12/2018

    1743-15-01

    DO

    NA

    LD E

    LEM

    EN

    TAR

    Y S

    CH

    OO

    LS

    TEM

    RE

    NO

    VA

    TIO

    NFO

    RLE

    WIS

    VIL

    LE I.

    S.D

    .FL

    OW

    ER

    MO

    UN

    D, T

    EX

    AS

    Rev

    isio

    n /

    Dat

    e

    1/8" = 1'-0"1REFLECTED CEILING PLAN - SECTION 2 N

    PLAN

    4

    3

    2

    1

    KEY PLAN - 1ST FLOOR

    N.T.S.

    1 1/2" = 1'-0"2WOOD CEILING DETAIL

    10-05-152-12-18

  • DOOR FRAME MATERIALS

    AL - ALUMINUM AS SCHEDULED AND SPECIFIED

    HM - HOLLOW METAL AS SCHEDULED AND SPECIFIED

    DOOR MATERIALS

    AL - ALUMINUM AS SCHEDULED AND SPECIFIED

    HM - HOLLOW METAL AS SCHEDULED AND SPECIFIED

    SC - SOLID CORE WOOD AS SCHEDULED AND SPECIFIED

    GLAZING LEGEND

    CTG - CLEAR TEMPERED GLASS

    LTSG - LAMINATED TEMPERED SAFETY GLASS

    CAG - 1/2" THICK CLEAR ANNEALED GLASS W/ STRUCTURALLYAPPLIED SAFETY AND SECURITY FILM SYSTEM

    1.) ALL GLAZING IS 1/4" THICK (U.N.O.). INSULATED GLASS SHALL CONSISTOF AN EXTERIOR LAYER OF GLASS, TINTED AS SPECIFIED, AN INTERIORLAYER OF CLEAR GLASS, FACTORY SEALED WITH A 1/2" AIR SPACE.WHERE TEMPERED GLASS IS SPECIFIED, BOTH LAYERS OF INSULATEDGLASS SHALL BE TEMPERED.

    2.) ANY WINDOW OR GLAZING PANELS LOCATED AT A INTERSTITIALSPACE OR NOT READILY VISIBLE SHALL HAVE SPANDREL GLASSINSTALLED, REGARDLESS OF ANY NOTATION ELSEWHERE.

    DOOR ASSEMBLY NOTES

    DEFAULT DOORS

    IF A DOOR ASSEMBLY APPEARS ON THE FLOOR PLANS BUT IS NOTIDENTIFIED BY A SCHEDULE NUMBER, THE DOOR SHALL BE INCLUDEDIN THE BID AS LISTED BELOW. THE CONTRACTOR SHALL REQUESTCLARIFICATION FROM THE ARCHITECT TO DETERMINE WHAT THEACTUAL DOOR AND FRAME TYPE AND HARDWARE REQUIREMENTSWILL BE. ADJUSTMENTS IN CONTRACT PRICE WILL BE BASED ON THEDIFFERENCE BETWEEN ACTUAL REQUIREMENTS AND THE DEFAULTDOOR VALUE.

    THE DEFAULT EXTERIOR DOOR SHALL BE A TYPE "HM-FL" (SINGLE ORPAIR PER PLAN) IN A TYPE "B" FRAME WITH DEFAULT HARDWARE PERSPECIFICATIONS AND FRAME DETAILING PER TYPICAL DETAILS FOREXTERIOR DOORS.

    THE DEFAULT INTERIOR DOOR SHALL BE A TYPE "SC-FL" (SINGLE ORPAIR PER PLAN) IN A TYPE "B" FRAME WITH DEFAULT HARDWARE PERSPECIFICATIONS AND FRAME DETAILING PER TYPICAL DETAILS FORINTERIOR DOORS.

    TYPICAL NOTES

    A) DOOR TYPES ARE INDICATED AS A MATERIAL-CONFIGURATION CODE.THE MATERIAL CODE DESIGNATES MATERIALS AND FINISHES ASSPECIFIED. REFER TO SPECIAL NOTES FOR NON-TYPICAL FINISHES.THE CONFIGURATION CODE REFERS TO TYPICAL OR SPECIALCONFIGURATIONS AS DRAWN.

    B) DOOR ASSEMBLIES ARE NUMBERED BY ASSEMBLY. MULTIPLE SETSOF DOORS MAY OCCUR IN THE SAME FRAME ASSEMBLY (REFER TOSCHEDULE AND PLAN FOR QUANTITY). DOORS MAY OCCUR IN PAIRS(REFER TO SCHEDULE AND PLAN FOR INCIDENCE).

    C) FRAME CONFIGURATION IS DIAGRAMMATIC AND NOMINAL.DIMENSIONS SHALL BE ADJUSTED TO ACCOMMODATE DOOR SIZES ASSCHEDULED. WITHIN ANY HOLLOW METALASSEMBLY, THE WIDTH OFSIDELITES SHALL BE EQUAL AND SHALL NOT EXCEED 3'-0" U.N.O.

    D) ALTERNATE FINISHES CAN SOMETIMES HAVE AN IMPACT ONDETAILING (E.G. HALF OR OFFSET SADDLES EMPLOYED IN LIEU OFSTANDARD SADDLES WHEN ADJACENT TO THICKER FLOOR FINISHESSUCH AS TERRAZZO OR QUARRY TILE). COORDINATE DETAILS WITHFINAL FINISH SELECTIONS.

    E) GLAZED FRAMES ASSOCIATED WITH 20-MINUTE OR 45-MINUTE FIRE-RATED DOORS SHALL BE RATED 1-HOUR. GLAZED FRAMESASSOCIATED WITH 90-MINUTE FIRE-RATED DOORS SHALL BE RATED 2-HOUR. GLAZING MUST MEET CODE REQUIREMENTS, INCLUDING SIZELIMITATIONS, IN FIRE-RATED FRAMES.

    F) PROVIDE 2x BLOCKING @ MTL STUD WALLS FOR WALL MOUNTEDITEMS LIKE; WALL STOPS, HOLD OPENS ETC.

    G) REFER TO FLOOR PLANS AND EXTERIOR ELEVATIONS FORALUMINUM FRAME LOCATIONS.

    SCHEDULE ABBREVIATIONS

    TIM - TYP INTERIOR MASONRY DETAIL - HM

    TIMA - TYP INTERIOR MASONRY DETAIL - ALUM

    TDW - TYP DRYWALL PARTITION DETAIL - HM

    TDWA - TYP DRYWALL PARTITION DETAIL - ALUM

    TH - THRESHOLD

    SEC - SECURITY CONTACTS (REF. ELEC. AND TECH.)

    OH - DENOTES OPPOSITE HAND CONFIGURATION

    DOOR FRAME CONFIGURATIONS

    DOOR NUMBER -REF. SCHED.

    FRAME TYPE - REF.CONFIGURATIONELEV.

    1' -

    6"

    5' -

    4"CTG CTG

    CTG CTG

    A.F.F

    EQ.2"EQ.

    4' - 0"

    /T.D.W. A3.1

    /T

    .E.D

    .W.

    A3.

    1

    /T.E.D.W. A3.1

    /T

    .D.W

    .A

    3.1

    5' -

    4"

    1' -

    6"

    A3.1

    T.D.W. Sim

    EXISTING WALL TOREMAIN (BEYOND)

    EXISTING CEILING TOREMAIN

    FIN FLOOR

    100' - 0" EXISTING

    WDW HEAD

    106' - 10"

    E.J. FLOORCOVER

    EXISTING WALLTO REMAIN

    5/8" GYP BD. ON 3 5/8"C.F.M.F. STUDS @ 1'-4" O.C. (MAX)

    5/8" GYP BD.

    HM FRAME ANDGLAZING - REF.

    WINDOW CONFIG.TP01; SHOWNDASHED

    C.F.M.F BOXEDHEADER

    WDW SILL

    101' - 6"

    A3.1

    2 Sim

    A3.1

    T.E.D.W. Sim

    CLASSROOM CORRIDOR

    PNT02

    TYPICAL EXISTING DRYWALL DETAILS (T.E.D.W.) SCALE 1-1/2" = 1'-0

    VERIFY WALL THICKNESS TODETERMINE FRAME SIZES.EXIST. GYP BD. EA

    SIDE - FIELD VERIFYWALL THICKNESS

    H.M. FRAMEAS SCHED.

    PROVIDE 3 CFMF ATEACH JAMB

    CONT. SEALANT PROVIDE 3 JAMBANCHORS @ EA JAMB.

    EXIST. GYP BD. EASIDE - FIELD VERIFYWALL THICKNESS

    H.M. FRAME AS SCHED.

    EXIST DOOR/WDW HEAD DETAIL EXIST DOOR/WDW JAMB DETAIL

    W.T.

    FRAME DEPTH = W.T. + 1 1/8"

    2"

    EXIST. CFMF -CONTRACTOR TO

    VERIFY EXIST.WALL CONDITION INSTALL CFMF

    HEADER

    AS R

    EQ.

    EXIST. CFMF-CONTRACTOR TO

    VERIFY EXIST.WALL CONDITION

    AS R

    EQ.

    WINDOW FRAME MATERIALS

    AL - ALUMINUM FRAME AS SCHEDULED AND SPECIFIED

    HM - HOLLOW METAL AS SCHEDULED AND SPECIFIED

    WINDOW ASSEMBLY NOTES

    TYPICAL NOTES

    A) WINDOW FRAME TYPES ARE INDICATED AS A MATERIAL-CONFIGURATION CODE. THE MATERIAL CODE DESIGNATESMATERIALS AND FINISHES AS SPECIFIED. REFER TO SPECIAL NOTESFOR NON-TYPICAL FINISHES. THE CONFIGURATION CODE REFERSTO TYPICAL OR SPECIAL CONFIGURATIONS AS DRAWN.

    B) WINDOW FRAME CONFIGURATION IS DIAGRAMMATIC ANDNOMINAL. SIZE SHALL BE ADJUSTED FOR INSTALLATIONCLEARANCES. WITHIN ANY ASSEMBLY, THE WIDTH OF SIDELITESSHALL BE EQUAL AND SHALL NOT EXCEED 3' - 0" U.N.O.

    GLAZING LEGEND

    CTG - CLEAR TEMPERED GLASS

    FRG - FIRE RATED GLASS

    GIT - GREY INSULATED TEMPERED GLASS

    ISG - INSULATED SPANDREL GLASS

    LTSG - LAMINATED TEMPERED SAFETY GLASS

    1.) ALL GLAZING IS 1/4" THICK (U.N.O.). INSULATED GLASS SHALLCONSIST OF AN EXTERIOR LAYER OF GLASS, TINTED AS SPECIFIED, ANINTERIOR LAYER OF CLEAR GLASS, FACTORY SEALED WITH A 1/2" AIRSPACE. WHERE TEMPERED GLASS IS SPECIFIED, BOTH LAYERS OFINSULATED GLASS SHALL BE TEMPERED.

    2.) ANY WINDOW OR GLAZING PANELS LOCATED AT A INTERSTITIALSPACE OR NOT READILY VISIBLE SHALL HAVE SPANDREL GLASSINSTALLED, REGARDLESS OF ANY NOTATION ELSEWHERE.

    ALUM CORNER GUARD EQ.TO SCHLUTER