PROJECT: EXPERIMENTAL LANDFILL JOINVILLE-SC · EXPERIMENTAL LANDFILL JOINVILLE-SC GEOTECHNICAL...

19
PROJECT: REPORT: EXPERIMENTAL LANDFILL URS-01-GRE-02 JOINVILLE-SC GEOTECHNICAL INVESTIGATION

Transcript of PROJECT: EXPERIMENTAL LANDFILL JOINVILLE-SC · EXPERIMENTAL LANDFILL JOINVILLE-SC GEOTECHNICAL...

Page 1: PROJECT: EXPERIMENTAL LANDFILL JOINVILLE-SC · EXPERIMENTAL LANDFILL JOINVILLE-SC GEOTECHNICAL INVESTIGATION ... • ASTM D-5778-07 ... Soil type 11 and 12 are overconsolidated or

PROJECT:

REPORT:

EXPERIMENTAL LANDFILL

URS-01-GRE-02

JOINVILLE-SC

GEOTECHNICAL INVESTIGATION

 

 

 

 

 

 

 

 

                                                                       

 

 

 

 

 

Page 2: PROJECT: EXPERIMENTAL LANDFILL JOINVILLE-SC · EXPERIMENTAL LANDFILL JOINVILLE-SC GEOTECHNICAL INVESTIGATION ... • ASTM D-5778-07 ... Soil type 11 and 12 are overconsolidated or

PROJECT:

REPORT:

CLIENT:

2 1/23/2015

1 8/18/2014

0 8/11/2014

REV. DATA

UNIVERSIDADE FEDERAL DO RIO GRANDE DO SUL

EXPERIMENTAL LANDFILL

JOINVILLE-SC

GEOTECHNICAL INVESTIGATION

URS-01-GRE-02

FIRST PUBLICATION

DESCRIPTION

ENGLISH VERSION 000591

000591

APROV

000591

800007

BY

GENERAL REVISION 800007 000591

FUGRO IN SITU GEOTECNIA LTDA

RJ:

SP:

Rua Santa Luzia, 651, 32º Andar | Centro | Rio de Janeiro-RJ | CEP 20030-041 | Fone 21 2103 9400

Rua Apucarana, 895 | Emiliano Perneta | Pinhais-PR | CEP 83324-450 | Fone 41 3345 1424 e 41 3033 9350

Av. Comandante Videlmo Munhoz, 303 Anhagabaú | | Jundiaí-SP | CEP 13208-050 | Fone 11 4596 5921

PR:

www.fugroinsitu.com.br

Page 3: PROJECT: EXPERIMENTAL LANDFILL JOINVILLE-SC · EXPERIMENTAL LANDFILL JOINVILLE-SC GEOTECHNICAL INVESTIGATION ... • ASTM D-5778-07 ... Soil type 11 and 12 are overconsolidated or

URS-01-GRE-02

TABLE OF CONTENTS

1. INTRODUCTION ..................................................................................................... 3

2. RECEIVED DOCUMENTS ....................................................................................... 4

3. CONE PENETRATION TESTING (CPTU) ............................................................... 5

3.1. Standards .............................................................................................................. 5

3.2. Procedures ............................................................................................................ 5

3.3. Location, Amount and Depth of Tests ................................................................... 6

3.4. Results .................................................................................................................. 7

4. FINAL CONSIDERATIONS ..................................................................................... 8

APPENDIX I – TESTS LOCATION MAP APPENDIX II – PIEZOCONE PENETRATION TESTING – CPTU

Page 4: PROJECT: EXPERIMENTAL LANDFILL JOINVILLE-SC · EXPERIMENTAL LANDFILL JOINVILLE-SC GEOTECHNICAL INVESTIGATION ... • ASTM D-5778-07 ... Soil type 11 and 12 are overconsolidated or

URS-01-GRE-02

3

1. INTRODUCTION The present report has the goal to describe the geotechnical investigation campaign performed by

piezocone penetration testing – CPTu, executed for Universidade Federal do Rio Grande do Sul,

at Experimental Landfill, in Joinville/SC.

Field work was performed between 06/24/2014 and 06/27/2014.

The present geotechnical investigation contemplated:

• Seven (07) cone penetration testing – CPTu.

Page 5: PROJECT: EXPERIMENTAL LANDFILL JOINVILLE-SC · EXPERIMENTAL LANDFILL JOINVILLE-SC GEOTECHNICAL INVESTIGATION ... • ASTM D-5778-07 ... Soil type 11 and 12 are overconsolidated or

URS-01-GRE-02

4

2. RECEIVED DOCUMENTS

Were provided for the report execution:

• Pile Location Map (Appendix I);

• Tests elevations and coordinates.

Page 6: PROJECT: EXPERIMENTAL LANDFILL JOINVILLE-SC · EXPERIMENTAL LANDFILL JOINVILLE-SC GEOTECHNICAL INVESTIGATION ... • ASTM D-5778-07 ... Soil type 11 and 12 are overconsolidated or

URS-01-GRE-02

5

3. CONE PENETRATION TESTING (CPTu) 3.1. Standards

• NBR 12069/91 - Solo - Ensaio de penetração de cone in situ (CPT);

• PROC-INV-04 – Ensaio de penetração de cone com medida de poropressão – CPTu;

• ASTM D-5778-07 - Standard test method for performing electronic friction cone and

piezocone testing of soils.

3.2. Procedures

Cone Penetration Testing CPTu Cone penetration testing with pore pressure measurement are used to stratigraphic determination

of soils profile, determining properties of materials prospected, particularly in deposits of soft clays

and prediction of bearing capacity of foundations. The test provides cone resistance, friction and

pore pressure data.

Test consists in a static spiking of a rod into soil, which at it lower end a conic tip, as showed in

Figure 1, (vertex angle of 60°) and cross section of 10 cm2.

Figure 1 – Cone system.

Page 7: PROJECT: EXPERIMENTAL LANDFILL JOINVILLE-SC · EXPERIMENTAL LANDFILL JOINVILLE-SC GEOTECHNICAL INVESTIGATION ... • ASTM D-5778-07 ... Soil type 11 and 12 are overconsolidated or

URS-01-GRE-02

6

Tests were performed by a static penetrometer from Italy (Pagani) with a reaction capacity of 200

kN (20 tf). Hydraulic system of penetrometers is triggered by a diesel engine achieving the reaction

through helical anchors. Tip and electronic devices used are from Fugro Engineers B.V..

Regarding pore pressure measurements, all standards procedures of the maintenance of system

saturation were observed. Regarding all tests, the tip was spiked at a constant speed, about 2

cm/s. Cone used was number 3634.

While rods are spiked into soil data is gathered each 2 cm depth, providing the following

information:

• Cone resistance (qc);

• Friction (fs), measured in a glove with lateral area of 150 cm2;

• Pore pressure, measured using a porous bronze element, locate at cone tip (u2);

• Inclination angle of cone tip regarding vertical.

These magnitudes are measured through precise instrumentation, well calibrated, installed at the

end of calibration set up, data are transmitted to surface by a cable system. Data are gathered,

transferred and stored in a computer. Tests results may be visualized in real time.

Tests involved execution of pre-drill, so the superficial landfill layer and/or resistance layer and

always hit the saturated zone.

Friction reducer was used in order to reduce friction in subsequent rods

3.3. Location, Amount and Depth of Tests Seven (07) cone penetration testing were performed. Maximum depth reached and pre-boring

depth are showed on Table 3.1.

Table 3.1 – Maximum depth of cone penetration testing - CPTu

Drill Pre-boring

(m) Final depth CPTu (m)

Location

North Coordinate

East Coordinate

Elevation (m)

CPTu-F01 2.19 30.02 7068829.27 727030.69 8.67

CPTu-F02 2.19 30.00 7068834.31 727028.67 8.68

CPTu-F03 2.15 30.01 7068832.36 727023.83 8.61

CPTu-F04 2.14 29.76 7068839.28 727026.65 8.69

Page 8: PROJECT: EXPERIMENTAL LANDFILL JOINVILLE-SC · EXPERIMENTAL LANDFILL JOINVILLE-SC GEOTECHNICAL INVESTIGATION ... • ASTM D-5778-07 ... Soil type 11 and 12 are overconsolidated or

URS-01-GRE-02

7

Drill Pre-boring

(m) Final depth CPTu (m)

Location

North Coordinate

East Coordinate

Elevation (m)

CPTu-F05 2.04 30.00 7068837.37 727021.84 8.57

CPTu-F06 2.14 29.80 7068842.40 727019.80 8.63

CPTu-F07 2.21 30.00 7068844.33 727024.63 8.74

3.4. Results

Cone Penetration Testing CPTu Tests results are showed on graphics of Appendix II, which indicates variation with depth of:

• Total cone resistance (qt), given by qt = qc + (1 - a) u2, a = 0,75 (calibration value);

• Friction (fs);

• Friction ratio (Rf), given by Rf = fs/qc;

• Pore pressure (u2).

Furthermore, the graphics presents in Appendix II may be used to stratigraphic classification of soil

behavior, based on Robertson et al. (1986) method. Figure 1 represents classification abacus.

Figure 2 – Robertson et al. (1986) classification system.

Page 9: PROJECT: EXPERIMENTAL LANDFILL JOINVILLE-SC · EXPERIMENTAL LANDFILL JOINVILLE-SC GEOTECHNICAL INVESTIGATION ... • ASTM D-5778-07 ... Soil type 11 and 12 are overconsolidated or

URS-01-GRE-02

8

4. FINAL CONSIDERATIONS All soundings and tests have the goal to gather punctual geotechnical information.

After the end of the tests, the hole were properly closed using coli (cement with bentonite).

Fugro In Situ Geotecnia Ltda. makes itself available to provide any additional information that may

be necessary.

Page 10: PROJECT: EXPERIMENTAL LANDFILL JOINVILLE-SC · EXPERIMENTAL LANDFILL JOINVILLE-SC GEOTECHNICAL INVESTIGATION ... • ASTM D-5778-07 ... Soil type 11 and 12 are overconsolidated or

URS-01-GRE-02

Attachment

APPENDIX I TESTS LOCATION MAP

Page 11: PROJECT: EXPERIMENTAL LANDFILL JOINVILLE-SC · EXPERIMENTAL LANDFILL JOINVILLE-SC GEOTECHNICAL INVESTIGATION ... • ASTM D-5778-07 ... Soil type 11 and 12 are overconsolidated or
Page 12: PROJECT: EXPERIMENTAL LANDFILL JOINVILLE-SC · EXPERIMENTAL LANDFILL JOINVILLE-SC GEOTECHNICAL INVESTIGATION ... • ASTM D-5778-07 ... Soil type 11 and 12 are overconsolidated or

URS-01-GRE-02

Attachment

APPENDIX II PIEZOCONE PENETRATION TESTING – CPTU

Page 13: PROJECT: EXPERIMENTAL LANDFILL JOINVILLE-SC · EXPERIMENTAL LANDFILL JOINVILLE-SC GEOTECHNICAL INVESTIGATION ... • ASTM D-5778-07 ... Soil type 11 and 12 are overconsolidated or

Legend (Colors in Friction Ratio Profile)

Soil type 11 and 12 are overconsolidated or cemented

De

pth

(m

)

0 1 2 3 4 5 6 7 8 9 10

Friction Ratio (%)

0.1

1.0

10.0

100.0

Cone R

esis

tance (

MP

a)

12

34

5

6

7

8

9

10

1112

CPTu-F01

ARON 06/25/2014

Vertical Scale 1:200

UFRGS

GUILHERME VARELA

7068829

8.67727031

30.02

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

0 5 10 15 20 25 30 0 2 4 6 8 10

Soil classification with CPT data(after Robertson et al., 1986)

0 50 100 150 200 250

EXPERIMENTAL LANDFILL

0 500 1000 1500

8.0

7.0

6.0

5.0

4.0

3.0

2.0

1.0

0.0

-1.0

-2.0

-3.0

-4.0

-5.0

-6.0

-7.0

-8.0

-9.0

-10.0

-11.0

-12.0

-13.0

-14.0

-15.0

-16.0

-17.0

-18.0

-19.0

-20.0

-21.0

JOINVILLE/SC

URS-01-GRE-02

1.70

1/1

Total Cone Resistanceqt (MPa)

Sleeve Frictionfs (kPa)

Friction RatioRf (%)

Porewater Pressureu (kPa)

7 Silty sand to sandy silt

8 Sand to silty sand

9 Sand

10 Gravelly sand to sand

11 Very stiff fine grained soil

12 Sand to clayey sand

Project/Local:

Client:

Processed by: Test Date:

Coordinator/ Technical Manager:

FUGRO IN SITU GEOTECNIA

1 Sensitive, fine grained

2 Organic soils, peat

3 Clay

4 Clay to silty clay

5 Clayey silt to silty clay

6 Sandy silty to clayey silt

Coord. N:

Coord. E: Elelvation (m):

Final Depth (m):

Report Number:

Ele

va

tio

n (

m)

Water level (m):

Preboring (m): 0.00 - 2.19 Preboring (m): 0.00 - 2.19 Preboring (m): 0.00 - 2.19 Preboring (m): 0.00 - 2.19

Page 14: PROJECT: EXPERIMENTAL LANDFILL JOINVILLE-SC · EXPERIMENTAL LANDFILL JOINVILLE-SC GEOTECHNICAL INVESTIGATION ... • ASTM D-5778-07 ... Soil type 11 and 12 are overconsolidated or

Legend (Colors in Friction Ratio Profile)

Soil type 11 and 12 are overconsolidated or cemented

De

pth

(m

)

0 1 2 3 4 5 6 7 8 9 10

Friction Ratio (%)

0.1

1.0

10.0

100.0

Cone R

esis

tance (

MP

a)

12

34

5

6

7

8

9

10

1112

CPTu-F02

ARON 06/25/2014

Vertical Scale 1:200

UFRGS

GUILHERME VARELA

7068834

8.68727029

30.00

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

0 5 10 15 20 25 30 0 2 4 6 8 10

Soil classification with CPT data(after Robertson et al., 1986)

0 50 100 150 200 250

EXPERIMENTAL LANDFILL

0 500 1000 1500

8.0

7.0

6.0

5.0

4.0

3.0

2.0

1.0

0.0

-1.0

-2.0

-3.0

-4.0

-5.0

-6.0

-7.0

-8.0

-9.0

-10.0

-11.0

-12.0

-13.0

-14.0

-15.0

-16.0

-17.0

-18.0

-19.0

-20.0

-21.0

JOINVILLE/SC

URS-01-GRE-02

1.70

1/1

Total Cone Resistanceqt (MPa)

Sleeve Frictionfs (kPa)

Friction RatioRf (%)

Porewater Pressureu (kPa)

7 Silty sand to sandy silt

8 Sand to silty sand

9 Sand

10 Gravelly sand to sand

11 Very stiff fine grained soil

12 Sand to clayey sand

Project/Local:

Client:

Processed by: Test Date:

Coordinator/ Technical Manager:

FUGRO IN SITU GEOTECNIA

1 Sensitive, fine grained

2 Organic soils, peat

3 Clay

4 Clay to silty clay

5 Clayey silt to silty clay

6 Sandy silty to clayey silt

Coord. N:

Coord. E: Elelvation (m):

Final Depth (m):

Report Number:

Ele

va

tio

n (

m)

Water level (m):

Preboring (m): 0.00 - 2.19 Preboring (m): 0.00 - 2.19 Preboring (m): 0.00 - 2.19 Preboring (m): 0.00 - 2.19

Page 15: PROJECT: EXPERIMENTAL LANDFILL JOINVILLE-SC · EXPERIMENTAL LANDFILL JOINVILLE-SC GEOTECHNICAL INVESTIGATION ... • ASTM D-5778-07 ... Soil type 11 and 12 are overconsolidated or

Legend (Colors in Friction Ratio Profile)

Soil type 11 and 12 are overconsolidated or cemented

De

pth

(m

)

0 1 2 3 4 5 6 7 8 9 10

Friction Ratio (%)

0.1

1.0

10.0

100.0

Cone R

esis

tance (

MP

a)

12

34

5

6

7

8

9

10

1112

CPTu-F03

ARON 06/24/2014

Vertical Scale 1:200

UFRGS

GUILHERME VARELA

7068832

8.61727024

30.01

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

0 5 10 15 20 25 30 0 2 4 6 8 10

Soil classification with CPT data(after Robertson et al., 1986)

0 50 100 150 200 250

EXPERIMENTAL LANDFILL

0 500 1000 1500

8.0

7.0

6.0

5.0

4.0

3.0

2.0

1.0

0.0

-1.0

-2.0

-3.0

-4.0

-5.0

-6.0

-7.0

-8.0

-9.0

-10.0

-11.0

-12.0

-13.0

-14.0

-15.0

-16.0

-17.0

-18.0

-19.0

-20.0

-21.0

JOINVILLE/SC

URS-01-GRE-02

1.70

1/1

Total Cone Resistanceqt (MPa)

Sleeve Frictionfs (kPa)

Friction RatioRf (%)

Porewater Pressureu (kPa)

7 Silty sand to sandy silt

8 Sand to silty sand

9 Sand

10 Gravelly sand to sand

11 Very stiff fine grained soil

12 Sand to clayey sand

Project/Local:

Client:

Processed by: Test Date:

Coordinator/ Technical Manager:

FUGRO IN SITU GEOTECNIA

1 Sensitive, fine grained

2 Organic soils, peat

3 Clay

4 Clay to silty clay

5 Clayey silt to silty clay

6 Sandy silty to clayey silt

Coord. N:

Coord. E: Elelvation (m):

Final Depth (m):

Report Number:

Ele

va

tio

n (

m)

Water level (m):

Preboring (m): 0.00 - 2.15 Preboring (m): 0.00 - 2.15 Preboring (m): 0.00 - 2.15 Preboring (m): 0.00 - 2.15

Page 16: PROJECT: EXPERIMENTAL LANDFILL JOINVILLE-SC · EXPERIMENTAL LANDFILL JOINVILLE-SC GEOTECHNICAL INVESTIGATION ... • ASTM D-5778-07 ... Soil type 11 and 12 are overconsolidated or

Legend (Colors in Friction Ratio Profile)

Soil type 11 and 12 are overconsolidated or cemented

De

pth

(m

)

0 1 2 3 4 5 6 7 8 9 10

Friction Ratio (%)

0.1

1.0

10.0

100.0

Cone R

esis

tance (

MP

a)

12

34

5

6

7

8

9

10

1112

CPTu-F04

ARON 06/26/2014

Vertical Scale 1:200

UFRGS

GUILHERME VARELA

7068839

8.69727027

29.76

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

0 10 20 30 40 0 2 4 6 8 10

Soil classification with CPT data(after Robertson et al., 1986)

0 50 100 150 200 250 300

EXPERIMENTAL LANDFILL

0 500 1000 1500

8.0

7.0

6.0

5.0

4.0

3.0

2.0

1.0

0.0

-1.0

-2.0

-3.0

-4.0

-5.0

-6.0

-7.0

-8.0

-9.0

-10.0

-11.0

-12.0

-13.0

-14.0

-15.0

-16.0

-17.0

-18.0

-19.0

-20.0

-21.0

JOINVILLE/SC

URS-01-GRE-02

1.70

1/1

Total Cone Resistanceqt (MPa)

Sleeve Frictionfs (kPa)

Friction RatioRf (%)

Porewater Pressureu (kPa)

7 Silty sand to sandy silt

8 Sand to silty sand

9 Sand

10 Gravelly sand to sand

11 Very stiff fine grained soil

12 Sand to clayey sand

Project/Local:

Client:

Processed by: Test Date:

Coordinator/ Technical Manager:

FUGRO IN SITU GEOTECNIA

1 Sensitive, fine grained

2 Organic soils, peat

3 Clay

4 Clay to silty clay

5 Clayey silt to silty clay

6 Sandy silty to clayey silt

Coord. N:

Coord. E: Elelvation (m):

Final Depth (m):

Report Number:

Ele

va

tio

n (

m)

Water level (m):

Preboring (m): 0.00 - 2.14 Preboring (m): 0.00 - 2.14 Preboring (m): 0.00 - 2.14 Preboring (m): 0.00 - 2.14

Page 17: PROJECT: EXPERIMENTAL LANDFILL JOINVILLE-SC · EXPERIMENTAL LANDFILL JOINVILLE-SC GEOTECHNICAL INVESTIGATION ... • ASTM D-5778-07 ... Soil type 11 and 12 are overconsolidated or

Legend (Colors in Friction Ratio Profile)

Soil type 11 and 12 are overconsolidated or cemented

De

pth

(m

)

0 1 2 3 4 5 6 7 8 9 10

Friction Ratio (%)

0.1

1.0

10.0

100.0

Cone R

esis

tance (

MP

a)

12

34

5

6

7

8

9

10

1112

CPTu-F05

ARON 06/24/2014

Vertical Scale 1:200

UFRGS

GUILHERME VARELA

7068837

8.57727022

30.00

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

0 5 10 15 20 25 30 0 2 4 6 8 10

Soil classification with CPT data(after Robertson et al., 1986)

0 50 100 150 200 250

EXPERIMENTAL LANDFILL

0 500 1000 1500

8.0

7.0

6.0

5.0

4.0

3.0

2.0

1.0

0.0

-1.0

-2.0

-3.0

-4.0

-5.0

-6.0

-7.0

-8.0

-9.0

-10.0

-11.0

-12.0

-13.0

-14.0

-15.0

-16.0

-17.0

-18.0

-19.0

-20.0

-21.0

JOINVILLE/SC

URS-01-GRE-02

1.70

1/1

Total Cone Resistanceqt (MPa)

Sleeve Frictionfs (kPa)

Friction RatioRf (%)

Porewater Pressureu (kPa)

7 Silty sand to sandy silt

8 Sand to silty sand

9 Sand

10 Gravelly sand to sand

11 Very stiff fine grained soil

12 Sand to clayey sand

Project/Local:

Client:

Processed by: Test Date:

Coordinator/ Technical Manager:

FUGRO IN SITU GEOTECNIA

1 Sensitive, fine grained

2 Organic soils, peat

3 Clay

4 Clay to silty clay

5 Clayey silt to silty clay

6 Sandy silty to clayey silt

Coord. N:

Coord. E: Elelvation (m):

Final Depth (m):

Report Number:

Ele

va

tio

n (

m)

Water level (m):

Preboring (m): 0.00 - 2.04 Preboring (m): 0.00 - 2.04 Preboring (m): 0.00 - 2.04 Preboring (m): 0.00 - 2.04

Page 18: PROJECT: EXPERIMENTAL LANDFILL JOINVILLE-SC · EXPERIMENTAL LANDFILL JOINVILLE-SC GEOTECHNICAL INVESTIGATION ... • ASTM D-5778-07 ... Soil type 11 and 12 are overconsolidated or

Legend (Colors in Friction Ratio Profile)

Soil type 11 and 12 are overconsolidated or cemented

De

pth

(m

)

0 1 2 3 4 5 6 7 8 9 10

Friction Ratio (%)

0.1

1.0

10.0

100.0

Cone R

esis

tance (

MP

a)

12

34

5

6

7

8

9

10

1112

CPTu-F06

ARON 06/27/2014

Vertical Scale 1:200

UFRGS

GUILHERME VARELA

7068842

8.63727020

29.80

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

0 5 10 15 20 25 30 0 2 4 6 8 10

Soil classification with CPT data(after Robertson et al., 1986)

0 50 100 150 200 250

EXPERIMENTAL LANDFILL

0 500 1000 1500

8.0

7.0

6.0

5.0

4.0

3.0

2.0

1.0

0.0

-1.0

-2.0

-3.0

-4.0

-5.0

-6.0

-7.0

-8.0

-9.0

-10.0

-11.0

-12.0

-13.0

-14.0

-15.0

-16.0

-17.0

-18.0

-19.0

-20.0

-21.0

JOINVILLE/SC

URS-01-GRE-02

1.70

1/1

Total Cone Resistanceqt (MPa)

Sleeve Frictionfs (kPa)

Friction RatioRf (%)

Porewater Pressureu (kPa)

7 Silty sand to sandy silt

8 Sand to silty sand

9 Sand

10 Gravelly sand to sand

11 Very stiff fine grained soil

12 Sand to clayey sand

Project/Local:

Client:

Processed by: Test Date:

Coordinator/ Technical Manager:

FUGRO IN SITU GEOTECNIA

1 Sensitive, fine grained

2 Organic soils, peat

3 Clay

4 Clay to silty clay

5 Clayey silt to silty clay

6 Sandy silty to clayey silt

Coord. N:

Coord. E: Elelvation (m):

Final Depth (m):

Report Number:

Ele

va

tio

n (

m)

Water level (m):

Preboring (m): 0.00 - 2.21 Preboring (m): 0.00 - 2.21 Preboring (m): 0.00 - 2.21 Preboring (m): 0.00 - 2.21

Page 19: PROJECT: EXPERIMENTAL LANDFILL JOINVILLE-SC · EXPERIMENTAL LANDFILL JOINVILLE-SC GEOTECHNICAL INVESTIGATION ... • ASTM D-5778-07 ... Soil type 11 and 12 are overconsolidated or

Legend (Colors in Friction Ratio Profile)

Soil type 11 and 12 are overconsolidated or cemented

De

pth

(m

)

0 1 2 3 4 5 6 7 8 9 10

Friction Ratio (%)

0.1

1.0

10.0

100.0

Cone R

esis

tance (

MP

a)

12

34

5

6

7

8

9

10

1112

CPTu-F07

ARON 06/26/2014

Vertical Scale 1:200

UFRGS

GUILHERME VARELA

7068844

8.74727025

30.00

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

0 5 10 15 20 25 30 0 2 4 6 8 10

Soil classification with CPT data(after Robertson et al., 1986)

0 50 100 150 200 250

EXPERIMENTAL LANDFILL

0 500 1000 1500

8.0

7.0

6.0

5.0

4.0

3.0

2.0

1.0

0.0

-1.0

-2.0

-3.0

-4.0

-5.0

-6.0

-7.0

-8.0

-9.0

-10.0

-11.0

-12.0

-13.0

-14.0

-15.0

-16.0

-17.0

-18.0

-19.0

-20.0

-21.0

JOINVILLE/SC

URS-01-GRE-02

1.70

1/1

Total Cone Resistanceqt (MPa)

Sleeve Frictionfs (kPa)

Friction RatioRf (%)

Porewater Pressureu (kPa)

7 Silty sand to sandy silt

8 Sand to silty sand

9 Sand

10 Gravelly sand to sand

11 Very stiff fine grained soil

12 Sand to clayey sand

Project/Local:

Client:

Processed by: Test Date:

Coordinator/ Technical Manager:

FUGRO IN SITU GEOTECNIA

1 Sensitive, fine grained

2 Organic soils, peat

3 Clay

4 Clay to silty clay

5 Clayey silt to silty clay

6 Sandy silty to clayey silt

Coord. N:

Coord. E: Elelvation (m):

Final Depth (m):

Report Number:

Ele

va

tio

n (

m)

Water level (m):