User's Manual Visual KV Series 3 Programming 96M0366 How this manual is organized: The Visual KV Series User’s Manual is composed of 3 separate manuals; 1-Installation, 2-Support Software, 3-Programming. Please read each manual relevant to your purpose.

Transcript of Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the...

Page 1: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1 2 3

Visual KV Series 3 P

rogra

mm

ing

User's ManualVisual KV Series

3Programming

© KEYENCE CORPORATION, 1999 NKVP-UM-4-1000 Printed in Japan

96M0366

How this manual is organized:

The Visual KV Series User’s Manual is composed of 3 separatemanuals; 1-Installation, 2-Support Software, 3-Programming.Please read each manual relevant to your purpose.

Installation

1. Configuration andSpecifications

2. System Installation

3. Access Window

4. KV-D20 OperatorInterface Panel

5. KV-10/80 Hardware

6. Handheld Program-mer

7. KV-L2 Serial InterfaceModule

8. KV-AN6 Analog I/OModule

9. KV-AD4/DA4 AnalogI/O Unit

10. Troubleshooting

11. Appendices

SupportSoftware

1. Introduction

2. Editor

3. Simulator

4. Monitor

5. Appendices

Programming

1. Programming

2. Instructions

3. Interrupts

4. High-speed Counters

5. Positioning Control

6. Interrupts, High-speedCounters, PositioningControl

7. Serial Communication

8. ProgrammingExamples

INDEX

Specifications are subject to change without notice.

KEYENCE CORPORATION1-3-14, Higashi-Nakajima,Higashi-Yodogawa-ku,Osaka, 533-8555, JapanPHONE: 81-6-6379-2211FAX: 81-6-6379-2131

AFFILIATED COMPANIES

KEYENCE CORPORATION OF AMERICAPHONE: 201-930-0100 FAX: 201-930-0099

KEYENCE (UK) LIMITEDPHONE: 01908-696900 FAX: 01908-696777

KEYENCE DEUTSCHLAND GmbHPHONE: 0711-79 73 71-0 FAX: 0711-797 77 99

KEYENCE FRANCE S.A.PHONE: 01 47 92 76 76 FAX: 01 47 92 76 77

KEYENCE SINGAPORE PTE LTD.PHONE: 392-1011 FAX: 392-5055

KEYENCE (MALAYSIA) SDN BHDPHONE: 03-252-2211 FAX: 03-252-2131

KEYENCE (THAILAND) CO., LTD.PHONE: 02-369-2777 FAX: 02-369-2775

KEYENCE THAIWAN CO., LTD.PHONE: 02-2627-3100 FAX: 02-2798-8925

KEYENCE KOREA CORPORATIONPHONE: 02-563-1270 FAX: 02-563-1271

Page 2: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

Safety PrecautionsThis instruction manual describes the operation and function of the KV Series PLC.Read this manual carefully to ensure safe use and maximum performance from yourKV Series PLC.

SymbolsThe following symbols alert you to important messages. Be sure to read thesemessages carefully.

Failure to follow instructions may lead to injury. (electricshock, burn, etc.)

Failure to follow instructions may lead to product damage.

Provides additional information on proper operation.

ConventionsThis manual describes the operation/function of all Keyence KV Series PLC.Note following conventions when you use.

General Precautions• At startup and during operation, be sure to monitor the functions and perfor-

mance of the KV Sereis PLC.

• We recommend that you take substantial safety measures to avoid any damagein the event a problem occurs.

• Do not open or modify the KV Series PLC or use it in any way other than de-scribed in the specifications.

• When the KV Series PLC is used in combination with other instruments, func-tions and performance may be degraded, depending on operating conditions andthe surrounding environment.

• Do not use the KV Series PLC for the purpose of protecting the human body.

Note: The built-in display may show the error message "Error 40" blinking the veryfirst time you turn on the power supply to the Visual KV Series. Press any keyaround the display to cancel this message.The Visual KV Series shows this message when no program is loaded.

WARNING

CAUTION

Note:

(1)

Visual KV (Series) KV-10AR/AT/DR/DT KV-16AR/AT/DR/DTKV-10xx, 16xx, 24xx, 40xx KV-24AR/AT/DR/DT KV-40AR/AT/DR/DT

Conventional KV (Series) KV-10R(W)/T(W) KV-16R(W)/T(W)KV-300 (Series) KV-24R(W)/T(W) KV-40R(W)/T(W)KV-10/80 (Series) KV-80R(W)/T(W)

KV-300

Page 3: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

Note to UserWhen using the Visual KV Series in the following conditions or environments, besure to use the Visual KV Series with sufficient margin regarding the rating andfunctions, take appropriate safety precautions such as fail-safe, and contact oursales personnel if any questions arise.

• Use in conditions or environments not described in this manual

• Use for nuclear power control, railway facilities, air service facilities, vehicles,combustion devices, medical equipment, amusement machines, safety equip-ment, etc.

• Use for applications where large effects are predicted to be given on human livesand properties and safety is especially requested.

Restriction on Acquiring the CE Marking Restriction to be compatible with EMC directives

• When using a relay output type unit (whose model name ends with "R"), connectspark killers having the appropriate withstand voltage against the load to theoutput terminals in parallel to contacts (because the unit discharges when a relaycontact becomes open and noise is generated). In our experiments, we use thefollowing models of spark killers.

XEB0101 0.1 µF-10 Ω manufactured by OKAYA DENKI SANGYO

The following 1-turn ferrite core is added to the AC power input circuit of the KV-40AR/T, the KV-24AR/T and to the DC power input circuit of the KV-40DR/T.

ZCAT3035-1330 manufactured by TDK

Note: The contents above do not by themselves ensure that the entire machinemanufactured in accordance with the above contents is compatible with EMCdirectives.

You must judge by yourself whether or not the entire machine is compatible withEMC directives because compatibility may change depending on the componentconfiguration, wiring and location inside of the machine.

Restriction on compatibility with low-voltage directives (IEC-1010-1)

• Use insulated type crimp-style terminals.

• For wiring materials, use lead wires whose sheath is 0.4 mm or more.

• The Visual KV Series is allowed to be installed in a vertical position only.(Spacers for expansion units are not available.)

• Be sure to use the Visual KV Series inside the control panel.

(2)

Page 4: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

Features of the Visual KV Series Extremely small

The Visual KV Series is the smallest in the world among AC type PLCs equippedwith screw terminal blocks, and saves installation space.

Extremely fast

The minimum scan time is 140 µs and minimum instruction execution time is 0.7µs, which is the fastest control in its class.

AC power built-in type newly addedAC power built-in type units are newly added. This type can be used in smallspaces where a switching power supply unit cannot be installed.

Excellent Access Window

An Access Window with two-color backlight is adopted in all models to facilitatechanging and monitoring of device data. Changing between RUN mode andPROGRAM mode, checking the error code when an error has occurred, etc. canbe performed in a Visual KV Series unit without the need for any handheldprogrammer.The analog trimmer, which has been popular in the conventional KV Series, isdigitized to enable more detail settings. [Digital trimmers]

User message setting function

In the Access Window, 256 different user messages can be displayed. Thisfunction can be used to give instructions on works on the production line, indicateabnormalities in the units, etc.

Program write in RUN mode

Ladder programs can be changed even while the system is running.

Equipped with two serial portsVisual KV Series basic units are equipped with two serial ports to connect periph-eral units, improving the debug environment.(The KV-10xx is equipped with only one serial port.)

Easy Ramp-up/down control function

The one-axis motor control function is offered separately from high-speedcounters so that feedback control is enabled.

Equipped with two 24-bit high-speed 30 kHz, two-phase counters

The Visual KV Series is equipped with two high-speed counters each with a two-point comparator output function that enables high-speed encoder input.

Specified frequency pulse output function

High-speed counters can function as pulse oscillators of 50 kHz maximum witheasy setting, without creating a complicated ladder program.

Frequency counter functionHigh-speed counters can function as frequency counters with easy setting,without creating complicated ladder programs.

Cam switch function

High-speed counters can function as cam switches with easy setting, withoutcreating complicated ladder programs.

(3)

Page 5: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

Interrupt function

The Visual KV Series is equipped with four high-speed interrupt inputs of10 µs maximum.

Input time constant change function

The time constant can be set in 7 steps from 10 µs to 10 ms.

Double memory backup functionsIn addition to a conventional SRAM battery backup function, the Visual KV Seriesis also equipped with an EEPROM backup function.

Compatibility with Conventional KV Series Peripheral UnitsThe Visual KV Series functions as a high-end compatible model of the conventionalKV Series. Peripheral units of the conventional KV Series such as the ladder supportsoftware "KV IncrediWare (DOS)" and "LADDER BUILDER for KV" and thehandheld programmer KV-P3E(01) can be used since they are part of the Visual KVSeries.However, it should be noted that the contents have changed as follows.

• The internal clock cycle of high-speed counters consists of three types: 1 µs, 10µs, and 100 µs.

• The time constant for an input relay specified by the HSP instruction is 10 µs.

• The analog trimmer function is set with the Access Window built into the basicunit.

• The available device setting range of the TMIN instruction is from 0 to 65535.[Handheld programmer KV-P3E(01) can display 0 to 9999 .]

• The RUN/PROGRAM LED is displayed in the Access Window provided on thefront face of the basic unit.

• Transistor output is not independent, but is common.

• With the transistor type, the output terminal layout is different.

• The specifications for output current of transistor outputs Nos. 500 to 502 is 100mA.

• Conventional KV Series expansion units are not available as expansion units forthe Visual KV Series.

• The channel setting switch is not provided for expansion units. Channels aredetermined in connection order.

• Scans in expansion I/O units are not synchronous with the scan time in Visual KVSeries basic units.

• Assignment of special utility relays has partially changed.

• Data memory device Nos. DM1000 to DM1999 are assigned as special datamemories.

(4)

Page 6: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

Cautions when using the previous version of ladder support softwarePay strict attention to the following items when using the ladder support software.

• When using the ladder support software "KV IncrediWare (DOS)" or "LADDERBUILDER for KV Ver. 1.0x", set the model to "KV-300".

• DM0 to DM1999 are only available.

When the ladder support software "LADDER BUILDER for KV Ver. 1.0x" isused, do not use the monitor’s Change All function. If the Change All functionis used, the basic unit may be damaged. Never use the Change All function.

Peripheral units and other units incompatible with the Visual KV SeriesPeripheral units in the conventional KV Series and other units shown below are notcompatible with the Visual KV Series.

• Expansion I/O units for the conventional KV Series: KV-8ER/8ET/8EX/16EX/8EYR/8EYT/16EYR/16EYT

• Analog I/O units for the conventional KV Series: KV-AD4/DA4

Cautions when Using the Serial PortThe KV-16xx/24xx/40xx units are equipped with two RJ-11 modular connectors forserial communication.When using them, pay strict attention to the following contents:

• Programs can be transferred and monitored using either communication port A orB. However, never connect the ladder software and a handheld programmer tothe two ports at the same time.

• The KV-D20 operator interface panel can be connected to either communicationport A or B. However, only one KV-D20 unit can be connected to a single basicunit.

• Never leave both the KV-D20 operator interface panel and KV-P3E(01) handheldprogrammer on simultaneously for a long period of time.

CAUTION

(5)

Page 7: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

(6)

Page 8: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

(7)

How this manual is organizedThe Visual KV Series User’s Manual is composed of 3 separate manuals;1-Installation, 2-Support Software, 3-Programming. Please read each manualrelevant to your purpose.

1 InstallationChapter 1 Configuration and Specifications [Visual KV Series Only]

Describes the system configuration of the Visual KV Series, the names and functions ofeach part, and the specifications.

Chapter 2 System Installation [Visual KV Series Only]Describes the installation and connection of each Visual KV Series unit as well assystem maintenance.

Chapter 3 Access Window [Visual KV Series Only]Describes the Access Window used for changing and monitoring data.

Chapter 4 KV-D20 Operator Interface Panel [Visual KV Series Only]Describes the KV-D20 Operator Interface Panel used for changing, monitoring, anddisplaying the status of inside relays, timers, counters and data memories.

Chapter 5 KV-300, KV-10/80 Hardware [KV-300, KV-10/80 Series Only]Describes the hardware specifications and wirings for KV-300 and KV-10/80 Series.

Chapter 6 Handheld ProgrammerDescribes how to use the handheld programmer and memory card.

Chapter 7 KV-L2 Serial Interface Module [KV-300 Series Only]Describes the serial interface modules for KV-300 Series.

Chapter 8 KV-AN6 Analog I/O Module [KV-300 Series Only]Describes the optional Analog I/O module for KV-300 Series

Chapter 9 KV-AD4/DA4 Analog I/O Unit [KV-10/80 Series Only]Describes the optional Analog I/O unit for KV-10/80 Series.

Chapter 10 TroubleshootingThis chapter describes the error code list, countermeasures against problems, and errorindications for each unit.

AppendicesThe appendix includes a list of ladder program applications and the index.

2 Support SoftwareChapter 1 Introduction

Describes the items included in the package, the product outline, the method to connecta personal computer, the installation method, etc.

Page 9: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

(8)

Chapter 2 EditorDescribes the operating procedures in Editor mode.

Chapter 3 SimulatorDescribes the operating procedures in Simulator mode.

Chapter 4 MonitorDescribes the operating procedures in Monitor mode.

AppendicesIncludes instructions list, devices list, sample program list and quick reference for keyoperation and shortcuts.

3 ProgrammingChapter 1 Programming

Describes basic knowledge including program creation procedures, device configuration,relay assignments, special functions to set and confirm Visual KV Series operations, aswell as the extended ladder diagrams. Understand the contents described here com-pletely at first before creating programs.

Chapter 2 InstructionsDescribes the concrete usage of instructions in the KV Series.Refer to "Chapter 3 Interrupts" on page 3-183 for details of interrupt instructions.Refer to "Chapter 4 High-speed counters" on page 3-195 for details of the high-speedcounters used in the application instruction.

Chapter 3 Interrupts [Visual KV Series Only]The interrupt processing function executes an interrupt program when an external inputor request from the high-speed counter comparator (interrupt factor) is encounteredduring KV operation.This chapter describes the types of interrupt factors as well as inputs and outputsencountered during interrupt processing.

Chapter 4 High-speed Counters [Visual KV Series Only]Describes high-speed counters and high-speed counter comparators, which allow high-speed pulse measurement and pulse output, independent of the scan time.

Chapter 5 Positioning Control [Visual KV Series Only]Describes ramp-up/down control of stepping motors and servo motors.

Chapter 6 Interrupts, High-speed Counters, Positioning Control [KV-300, KV-10/80 Series Only]Describes ramp-up/down control of stepping motors and servo motors.

Chapter 7 Serial CommunicationThe KV Series can be connected to an external device with an RS-232C interface toestablish communication.This chapter describes communications specifications, how to connect the KV Series toexternal devices, and how to perform communication.

Chapter 8 Programming ExamplesDescribes the typical programming examples for KV-10/80 Series. These programs canbe used for Visual KV Series. However, pay attention to the I/O addressing compatibilitybefore use.

Page 10: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

(9)

Contents 3 Programming

Chapter 1 Programming

1.1 Before Creating Programs ..............................................................................3-21.1.1 Flow from Introduction to Operation ...................................................................3-21.1.2 Scan Time ...........................................................................................................3-3

Scan time .....................................................................................................3-3Input response time delay ............................................................................3-3

1.2 User Memory ....................................................................................................3-41.2.1 Program Capacity ...............................................................................................3-4

Maximum number of lines in a program.......................................................3-4Calculating the byte count used ...................................................................3-4

1.3 Device Configuration .......................................................................................3-51.3.1 Device List ..........................................................................................................3-5

Relay list ......................................................................................................3-5List of I/O relays in basic units .....................................................................3-5List of relays in expansion units ...................................................................3-6

1.3.2 Relay No. ............................................................................................................3-7Address No. .................................................................................................3-7Contact No. ..................................................................................................3-8Channel No. .................................................................................................3-8

1.3.3 Assigning Relay Nos. ..........................................................................................3-81.3.4 Input Relays ........................................................................................................3-9

Basic unit .....................................................................................................3-9Expansion unit ...........................................................................................3-10

1.3.5 Output Relays ...................................................................................................3-10Output operation time ................................................................................3-10

1.3.6 Internal Utility Relays ........................................................................................3-11Retentive function of internal utility relays ..................................................3-11

1.3.7 Special Utility Relays ........................................................................................3-12Description .................................................................................................3-12

1.3.8 Special Utility Relay List ...................................................................................3-14Special relays and arithmetic operation flags ............................................3-14Special utility relays for high-speed counter(0) ..........................................3-14Special utility relays for high-speed counter(1) ..........................................3-15Other special utility relays ..........................................................................3-15

1.3.9 Timers and Counters ........................................................................................3-18Timer/Counter list .......................................................................................3-18Description .................................................................................................3-18

1.3.10 Data Memories .................................................................................................3-191.3.11 Temporary Data Memory ..................................................................................3-211.3.12 Relay Nos. and Functions .................................................................................3-22

1.4 Special Functions ..........................................................................................3-231.4.1 Input Time Constant Change Function .............................................................3-23

Setting the input time constant for basic units using special utility relays ..3-231.4.2 Modifying the Input Relay Time Constant .........................................................3-24

Modification within the CPU .......................................................................3-241.4.3 Constant Scan Time Mode ...............................................................................3-251.4.4 Output Disabled Function .................................................................................3-261.4.5 Input Refresh Disabled Function ......................................................................3-261.4.6 Contact Comment Save Function .....................................................................3-271.4.7 Special Functions .............................................................................................3-28

Constant Scan Time Mode ........................................................................3-28Output Disabled Function ..........................................................................3-28Input Refresh Disabled Function ................................................................3-28

1.5 Extended Ladder Diagrams ..........................................................................3-291.5.1 Features of Extended Ladder Diagrams ...........................................................3-291.5.2 Advantages of Extended Ladder Diagrams ......................................................3-301.5.3 Example of an Extended Ladder Diagram ........................................................3-31

Page 11: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

(10)

Chapter 2 Instructions

2.1 Instruction List [Visual KV Series] ..............................................................3-342.1.1 Basic Instructions ..............................................................................................3-342.1.2 Application Instructions .....................................................................................3-362.1.3 Arithmetic Instructions ......................................................................................3-382.1.4 Interrupt Instructions .........................................................................................3-412.1.5 Function No. List (Alphabetical order) ..............................................................3-41

2.2 Instruction List [KV-300 Series, KV-10/80] .................................................3-422.2.1 Basic Instructions ..............................................................................................3-422.2.2 Application Instructions .....................................................................................3-452.2.3 Arithmetic Instructions ......................................................................................3-482.2.4 Interrupt Instructions .........................................................................................3-54

2.3 Convention Details ........................................................................................3-55

2.4 Instruction Details ..........................................................................................3-562.4.1 Basic Instructions ..............................................................................................3-562.4.2 Application Instructions .....................................................................................3-952.4.3 Arithmetic Instructions ....................................................................................3-134

2.5 Programming Notes .....................................................................................3-189

Chapter 3 Interrupts Visual KV

3.1 Interrupt Instructions ...................................................................................3-192

3.2 Interrupt Processing ....................................................................................3-1943.2.1 Interrupt Processing ........................................................................................3-1943.2.2 Types of Interrupts ..........................................................................................3-1953.2.3 Interrupt Priority ..............................................................................................3-1963.2.4 Interrupt Program............................................................................................3-196

3.3 Direct Input/Output ......................................................................................3-1973.3.1 Direct Input .....................................................................................................3-1973.3.2 Direct Output ...................................................................................................3-197

3.4 Applications of Interrupt Programs ...........................................................3-1983.4.1 Interrupt with a Signal Converter ....................................................................3-1983.4.2 Interrupt with a High-speed Counter ...............................................................3-1993.4.3 Measuring the ON Time of High-speed Pulses ..............................................3-2003.4.4 Measuring the Period in which a Target Passes between Two Points ........... 3-201

Chapter 4 High-speed Counters Visual KV

4.1 High-speed Counter Instructions ...............................................................3-204

4.2 Outline of High-speed Counters .................................................................3-2064.2.1 High-speed Counters and High-speed Counter Comparators ........................ 3-206

Structure of high-speed counters and high-speed counter comparators .3-206Specifications of high-speed counters .....................................................3-208High-speed counter comparators .............................................................3-209

4.2.2 Internal Clock for High-speed Counters ..........................................................3-210

4.3 Setting and Operation of High-speed Counters ........................................3-2114.3.1 Reading the Current Value of the High-speed Counter ..................................3-2114.3.2 Preset Value of the High-speed Counter Comparator .................................... 3-2114.3.3 Comparator Output .........................................................................................3-2114.3.4 Count Input Method ........................................................................................3-2124.3.5 Resetting the High-speed Counter .................................................................3-2144.3.6 Differences with the CTH Instruction between the

Conventional and Visual KV Series ................................................................3-2164.3.7 Applications of High-speed Counters .............................................................3-217

4.4 Extended Functions of High-speed Counters ........................................... 3-2214.4.1 24-bit High-speed Counter ..............................................................................3-2214.4.2 Changing the Current Value of a 24-bit High-speed Counter ......................... 3-2234.4.3 Application Example of 24-bit High-speed Counter (single-phase input) .......3-2244.4.4 Ring Counter Function ....................................................................................3-2254.4.5 Applications of Ring Counters ........................................................................3-226

4.5 Special Functions Using High-speed Counters ........................................3-228

Page 12: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

(11)

4.5.1 Specified Frequency Pulse Output Function ..................................................3-2284.5.2 Applications of the Specified Frequency Pulse Output ...................................3-2294.5.3 Frequency Counter Function ..........................................................................3-2314.5.4 Applications of Frequency Counters ...............................................................3-2324.5.5 Cam Switch Function ......................................................................................3-233

Cam switch mode ....................................................................................3-233Multi-step comparator mode ....................................................................3-234Setting method .........................................................................................3-234

4.5.6 Application of the Cam Switch (Cam Switch Mode) .......................................3-236

4.6 Direct Clock Pulse Output ...........................................................................3-2374.6.1 Outline of Direct Clock Pulse Output ..............................................................3-2374.6.2 Pulse Output Setting with the High-speed Counter Comparator ....................3-238

Changing the pulse period and width .......................................................3-238Calculating the pulse period and comparator preset value ......................3-239Operation with special utility relays ..........................................................3-239

4.7 Examples of Direct Clock Pulse Output ....................................................3-2424.7.1 Example of Outputting a Pulse with 1:1 ON/OFF Ratio ..................................3-2424.7.2 Example of Outputting a Pulse with Variable ON/OFF Ratio ..........................3-2454.7.3 Example of Stopping the Pulse Output at a Specified Pulse Count ...............3-2494.7.4 Application of Direct Clock Pulse Output (Ramp-up/down control) ................3-251

Chapter 5 Positioning Control Visual KV

5.1 Outline of Positioning Control ....................................................................3-2545.1.1 Ramp-up/down Control ...................................................................................3-254

5.2 Parameter Setting and Operating Procedures ..........................................3-2555.2.1 Parameter Setting Procedure .........................................................................3-2555.2.2 Operating Procedure ......................................................................................3-257

5.3 Examples of Using the Positioning Control Function ..............................3-2585.3.1 Connection Example .......................................................................................3-2585.3.2 Tips .................................................................................................................3-2585.3.3 Application Examples of the Positioning Control Function .............................3-259

Chapter 6 Interrupts, High-speed Counters,Positioning Control KV-300, KV-10/80

6.1 Interrupt Instructions ...................................................................................3-2686.1.1 Description of Interrupts ..................................................................................3-268

Input processing for routine program and interrupt routine ......................3-268Types of interrupt .....................................................................................3-268Interrupt priority ........................................................................................3-269Interrupt routine ........................................................................................3-269Direct output .............................................................................................3-270Direct input ...............................................................................................3-270

6.1.2 Interrupt Instructions .......................................................................................3-271

6.2 Direct Clock Pulse ........................................................................................3-2766.2.1 Output of Direct Clock Pulse ...........................................................................3-276

Outline of High-Speed Counters ..............................................................3-276Outline of Pulse Output ............................................................................3-279Examples of Pulse Output .......................................................................3-284

6.3 Positioning Control ......................................................................................3-2966.3.1 Positioning Control (Ramp-up/down Control) .................................................3-296

Outline of positioning control ....................................................................3-296Setting and application of parameters .....................................................3-297Examples of stepping motor control .........................................................3-300

Chapter 7 Serial Communication

7.1 Communications Specifications ................................................................3-3067.1.1 Communications Specification ........................................................................3-3067.1.2 Connection with the KV Unit ...........................................................................3-3067.1.3 Connecting the KV-300 CPU to a Personal Computer ...................................3-307

7.2 Serial Communication .................................................................................3-3087.2.1 Command Transmission Procedure ...............................................................3-308

Page 13: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

(12)

7.2.2 Format of Commands/Responses ..................................................................3-3097.2.3 Communication Command/Response List .....................................................3-3107.2.4 Setting Communication Commands and Responses to Commands ..............3-3117.2.5 Other Response Codes ..................................................................................3-3157.2.6 Error Code List ................................................................................................3-3167.2.7 Example Program ...........................................................................................3-317

7.3 Loading Text Data ........................................................................................3-3187.3.1 Receiving Text Data .......................................................................................3-3187.3.2 Transmitting Text Data ...................................................................................3-3197.3.3 Sample Program .............................................................................................3-320

7.4 ASCII Code List ............................................................................................3-321

Chapter 8 Programming Examples

8.1 List .........................................................................................................3-324

8.2 Details .........................................................................................................3-3268.2.1 Reference Program Examples ........................................................................3-326

Basic Instructions .....................................................................................3-326Application Instructions ............................................................................3-334Arithmetic Instructions ..............................................................................3-343

WARRANTIES AND DISCLAIMERS 3-367

1 Installation

Chapter 1 Configuration and Specifications Visual KV

1.1 System Configuration ......................................................................................1-21.1.1 System Configuration .........................................................................................1-2

1.2 Specifications ...................................................................................................1-41.2.1 General Specifications ........................................................................................1-41.2.2 AC Power Specifications ....................................................................................1-5

Visual KV Series operation at power interruption ........................................1-51.2.3 Performance Specifications ................................................................................1-6

Data backup function against instantaneous power interruption .................1-7

1.3 Common I/O Specifications of Basic Units ...................................................1-81.3.1 Model of a Basic Unit ..........................................................................................1-81.3.2 Common I/O Specifications ................................................................................1-8

1.4 KV-10AR/AT(P)/DR/DT(P) (10-I/O Basic Unit) .............................................1-101.4.1 Part Names and Functions ...............................................................................1-101.4.2 Terminal Layout Drawings and I/O Circuit Diagrams ........................................1-11

KV-10AR/DR (Relay output type) ..............................................................1-11KV-10AT(P)/DT(P) (Transistor output type) ...............................................1-13

1.4.3 AC Power Input (KV-10AR/AT(P)) ....................................................................1-141.4.4 Relationship between Continuous Simultaneous ON Ratio and Ambient Temperature 1-151.4.5 Dimensions .......................................................................................................1-16

1.5 KV-16AR/AT(P)/DR/DT(P) (16-I/O Basic Unit) .............................................1-171.5.1 Part Names and Functions ...............................................................................1-171.5.2 Terminal Layout Drawings and I/O Circuit Diagrams ........................................1-18

KV-16AR/DR (Relay output type) ..............................................................1-18KV-16AT(P)/DT(P) (Transistor output type) ...............................................1-20

1.5.3 AC Power Input (KV-16AR/AT(P)) ....................................................................1-211.5.4 Relationship between Continuous Simultaneous ON Ratio and Ambient Temperature 1-221.5.5 Dimensions .......................................................................................................1-23

1.6 KV-24AR/AT(P)/DR/DT(P) (24-I/O Basic Unit) .............................................1-241.6.1 Part Names and Functions ...............................................................................1-241.6.2 Terminal Layout Drawings and I/O Circuit Diagrams ........................................1-25

KV-24AR/DR (Relay output type) ..............................................................1-25KV-24AT(P)/DT(P) (Transistor output type) ...............................................1-27

1.6.3 AC Power Input (KV-24AR/AT(P)) ....................................................................1-281.6.4 Relationship between Continuous Simultaneous ON Ratio and Ambient Temperature 1-291.6.5 Dimensions .......................................................................................................1-30

1.7 KV-40AR/AT(P)/DR/DT(P) (40-I/O Basic Unit) ..............................................1-31

Page 14: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

(13)

1.7.1 Part Names and Functions ...............................................................................1-311.7.2 Terminal Layout Drawings and I/O Circuit Diagrams ........................................1-32

KV-40AR/DR (Relay output type) ..............................................................1-32KV-40AT(P)/DT(P) (Transistor output type) ...............................................1-34

1.7.3 AC Power Input (KV-40AR/AT(P)) ....................................................................1-351.7.4 Relationship between Continuous Simultaneous ON Ratio and Ambient Temperature 1-361.7.5 Dimensions .......................................................................................................1-37

1.8 KV-E4X/E8X/E16X (Expansion Input Unit) ..................................................1-381.8.1 Part Names and Functions ...............................................................................1-381.8.2 Input Specifications ...........................................................................................1-381.8.3 Terminal Layout Drawings and Input Circuit Diagrams .................................... 1-39

KV-E4X (4-I/O expansion input unit) ..........................................................1-39KV-E8X (8-I/O expansion input unit) ..........................................................1-40KV-E16X (16-I/O expansion input unit) ......................................................1-41

1.8.4 Dimensions .......................................................................................................1-42

1.9 KV-E4R/E4T/E8R/E8T(P)/E16R/E16T(P) (Expansion Output Unit) .............1-431.9.1 Part Names and Functions ...............................................................................1-431.9.2 Output Specifications ........................................................................................1-43

KV-E4R/E8R/E16R (Relay output type) .....................................................1-44KV-E4T/E8T(P)/E16T(P) [Transistor output type (NPN/PNP)] ..................1-44

1.9.3 Terminal Layout Drawings and Input Circuit Diagrams .................................... 1-45KV-E4R [4-I/O expansion output unit (relay output type)] ..........................1-45KV-E4T [4-I/O expansion output unit transistor output type)] ....................1-46KV-E8R [8-I/O expansion output unit (relay output type)] ..........................1-47KV-E8T(P) [8-I/O expansion output unit (transistor output type)] ..............1-48KV-E16R [16-I/O expansion output unit (relay output type)] ......................1-49KV-E16T(P) [16-I/O expansion input unit (transistor output)] ....................1-50

1.9.4 Dimensions .......................................................................................................1-51

1.10 KV-E4XR/E4XT(P) (Expansion I/O Unit) .......................................................1-521.10.1 Part Names and Functions ...............................................................................1-521.10.2 Input Specifications ...........................................................................................1-531.10.3 Output Specifications ........................................................................................1-53

KV-E4XR (Relay output type) ....................................................................1-53KV-E4XT(P) (Transistor output type) .........................................................1-53

1.10.4 Terminal Layout Drawings and Input Circuit Diagrams .................................... 1-54KV-E4XR (Relay output type) ....................................................................1-54KV-E4XT(P) (Transistor output type) .........................................................1-56

1.10.5 Dimensions .......................................................................................................1-58

1.11 KV-D20 (Operator Interface Panel) ...............................................................1-591.11.1 Part Names and Functions ...............................................................................1-591.11.2 General Specifications ......................................................................................1-601.11.3 Functional Specifications ..................................................................................1-601.11.4 Dimensions .......................................................................................................1-61

Chapter 2 System Installation Visual KV

2.1 Installation Environment ...............................................................................1-642.1.1 Installation Environment ...................................................................................1-642.1.2 Installation Position ...........................................................................................1-652.1.3 Installation Procedure .......................................................................................1-66

Expansion unit spacer ................................................................................1-662.1.4 Cautions on Wiring for Each Unit ......................................................................1-67

Wiring procedures for basic units ...............................................................1-67Cautions on wiring for I/O units ..................................................................1-68Terminal .....................................................................................................1-68Cautions on grounding ...............................................................................1-69

2.1.5 Contact Protection ............................................................................................1-69

2.2 Connecting Visual KV Series Expansion Units ..........................................1-702.2.1 Visual KV Series Expansion Units ....................................................................1-702.2.2 Connecting Visual KV Series Expansion Units .................................................1-71

Connection methods ..................................................................................1-72Number of connectable units .....................................................................1-73

2.2.3 Confirming the Connection Settings of Expansion Units ..................................1-74Expansion unit relay list .............................................................................1-74Connection information for expansion units ...............................................1-75Input time constant for expansion units .....................................................1-76

Page 15: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

(14)

Clearing the input value when disconnecting .............................................1-762.2.4 Transferring I/O Information between Expansion Units and the Basic Unit ......1-77

When inputting ...........................................................................................1-77In the case of output ..................................................................................1-77

2.3 Inspection and Maintenance .........................................................................1-782.3.1 Inspection .........................................................................................................1-782.3.2 Maintenance .....................................................................................................1-78

Chapter 3 Access Window Visual KV

3.1 Overview of the Access Window ..................................................................1-803.1.1 What is the Access Window .............................................................................1-803.1.2 Access Window Use Examples ........................................................................1-80

3.2 Basic Operating Procedures .........................................................................1-813.2.1 Operation Mode ................................................................................................1-813.2.2 Access Window Modes .....................................................................................1-813.2.3 Part Names and Functions of the Access Window ...........................................1-823.2.4 Selecting Modes and Setting/Resetting Key Lock ............................................1-823.2.5 Turbo Function ..................................................................................................1-83

3.3 Digital Trimmer Mode ....................................................................................1-843.3.1 Function and Operating Procedure ...................................................................1-84

Key operation and screen display ..............................................................1-84Function and operating procedure .............................................................1-84

3.4 Device Mode ...................................................................................................1-873.4.1 Function and Operating Procedure ...................................................................1-87

Devices that can be displayed and changed .............................................1-87Key operation and screen display ..............................................................1-87Selecting the device and displaying the current value/set value ................1-88Changing a numeric value .........................................................................1-89Holding the setting .....................................................................................1-91

3.4.2 Screen Display for Each Device Type ..............................................................1-91Data memory (DM) ....................................................................................1-91Temporary data memory (TM) ...................................................................1-91Timer/counter (T/C) ....................................................................................1-92High-speed counter comparator (CTC) ......................................................1-92Trimmer (TRM) ..........................................................................................1-93Relay (RLY) ...............................................................................................1-93

3.5 System Mode ..................................................................................................1-943.5.1 Function and Operating Procedure ...................................................................1-94

Key operation and screen display ..............................................................1-94LOAD mode and SAVE mode ....................................................................1-96Display in LOAD/SAVE mode ....................................................................1-96

3.6 Message Display ............................................................................................1-973.6.1 Error Messages and Error Status .....................................................................1-973.6.2 User Messages .................................................................................................1-97

How to use the user messages ..................................................................1-98

Chapter 4 KV-D20 Operator Interface Panel Visual KV

4.1 Before Operation ..........................................................................................1-1004.1.1 Checking Package Contents ..........................................................................1-1004.1.2 Part Names and Functions .............................................................................1-1014.1.3 Details about the KV-D20 ...............................................................................1-102

General specifications ..............................................................................1-102Functional specifications ..........................................................................1-102Dimensions ..............................................................................................1-103

4.1.4 Installation and Environment ..........................................................................1-104Use environment ......................................................................................1-104Panel mounting ........................................................................................1-105

4.1.5 Inspection and Maintenance ...........................................................................1-106Inspection .................................................................................................1-106Maintenance ............................................................................................1-106

4.2 Overview and Operation ..............................................................................1-1074.2.1 Use Examples for the KV-D20 ........................................................................1-107

Page 16: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

(15)

4.2.2 Connection with the KV Series .......................................................................1-108Connection ...............................................................................................1-108Precautions ..............................................................................................1-108

4.2.3 Overview of the KV-D20 .................................................................................1-109Switching the display mode .....................................................................1-109Overview of each display mode ...............................................................1-110Assignment of relays/DM .........................................................................1-111Other functions .........................................................................................1-112Precautions about screen change function ..............................................1-115

4.2.4 Operator Mode ................................................................................................1-117Screen selection in operator mode ..........................................................1-117Operator screen .......................................................................................1-118Direct access screen ................................................................................1-126KV-I/O monitor screen .............................................................................1-127Switch comment screen ...........................................................................1-128Lamp comment screen ............................................................................1-128Screen change permission in operator mode ..........................................1-129

4.2.5 Device Mode ...................................................................................................1-130Device mode ............................................................................................1-130Operation example for device mode ........................................................1-132

4.2.6 System Mode ..................................................................................................1-134System mode ...........................................................................................1-134

4.3 Examples of Ladder Programs ...................................................................1-1354.3.1 Basic Ladder Programs ..................................................................................1-135

Before creating ladder programs .............................................................1-135Basic ladder programs .............................................................................1-136

4.3.2 Examples of Ladder Programs .......................................................................1-143Example of displaying user messages .....................................................1-143Example of displaying messages with titles .............................................1-145Example of position control ......................................................................1-146Example of frequency counter .................................................................1-149Example of 24-bit high-speed counter .....................................................1-152Example of cam switch function ...............................................................1-154

4.4 Appendix .......................................................................................................1-1584.4.1 Troubleshooting ..............................................................................................1-1584.4.2 Available Character List ..................................................................................1-1624.4.3 Comment Draft Sheet .....................................................................................1-163

Chapter 5 KV-300, KV-10/80 Hardware KV-300, KV-10/80

5.1 System Configuration ..................................................................................1-1665.1.1 KV-300 ............................................................................................................1-1665.1.2 KV-10/80 .........................................................................................................1-167

5.2 Module/Unit Specifications .........................................................................1-1685.2.1 Wiring: KV-U4 Power Supply Module .............................................................1-168

Parts and functions ..................................................................................1-1685.2.2 Wiring: KV-U5 DC Power Distribution Module ................................................1-169

Parts and functions ..................................................................................1-1695.2.3 Wiring: KV-300 CPU .......................................................................................1-170

Parts and functions ..................................................................................1-1705.2.4 Wiring: KV-C16X/C32X Connector Input Module ...........................................1-171

Parts and functions ..................................................................................1-1715.2.5 Wiring: KV-C32T/B16R/B16S Connector Output Module ...............................1-172

Parts and functions ..................................................................................1-1725.2.6 Wiring: KV-R1A I/O Distribution Module .........................................................1-173

Parts and functions ..................................................................................1-1735.2.7 Wiring: KV-R8X/R16X/R8R/R16R/R8T/R16T I/O Terminal Modules .............1-174

Parts and functions ..................................................................................1-1745.2.8 Module Names and Functions ........................................................................1-1755.2.9 Peripheral Equipment Names and Functions .................................................1-176

5.3 Module/Unit Connections ............................................................................1-1785.3.1 Environmental Requirements .........................................................................1-1785.3.2 Installation Guidelines .....................................................................................1-1785.3.3 Assembling the System ..................................................................................1-179

Connecting modules ................................................................................1-1795.3.4 Mounting to the DIN Rail .................................................................................1-1805.3.5 Removing the Terminal Block .........................................................................1-181

Page 17: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

(16)

5.3.6 Connecting the AC Power Supply Module and DC Power Distribution Module .... 1-182KV-U4 AC Power Supply Module ............................................................1-182KV-U5 DC Power Distribution Module .....................................................1-182

5.3.7 I/O Connectors ................................................................................................1-183KV-300 CPU ............................................................................................1-183KV-C16X/C32X ........................................................................................1-184KV-C32T/B16R/B16S ..............................................................................1-185KV-R8X/R16X/R8R/R16R/R8T/R16T ......................................................1-186

5.3.8 I/O Terminal Modules: Communication Cables and Power Distribution .........1-187Transmission distance by cable type .......................................................1-187Connection patterns .................................................................................1-187Incorrect wiring patterns ...........................................................................1-188Power distribution ....................................................................................1-188

5.3.9 Connector Assembly Instructions ...................................................................1-1895.3.10 KV-300 CPU I/O Indicators .............................................................................1-1915.3.11 KV-10/80 Expansion Units ..............................................................................1-1925.3.12 Mounting Environment ....................................................................................1-194

Chapter 6 Handheld Programmer

6.1 Using the Handheld Programmer ...............................................................1-1966.1.1 Outline of the Handheld Programmer .............................................................1-1966.1.2 Precautions .....................................................................................................1-198

6.2 Basic Operations .........................................................................................1-2006.2.1 Basic Programming Operation ........................................................................1-200

6.3 Functions ......................................................................................................1-216Function Nos. list .....................................................................................1-216ALL CLEAR ..............................................................................................1-217HANDHELD PROGRAMMER CLEAR .....................................................1-217COUNTER CLEAR ..................................................................................1-218HIGH-SPEED COUNTER CLEAR ...........................................................1-218ALL DATA MEMORY CLEAR ..................................................................1-219ALL LATCHING RELAYS RESET ...........................................................1-219PROGRAM SENT OR RECEIVED ..........................................................1-220OFFLINE EDITOR START ......................................................................1-221OFFLINE EDITOR STOP ........................................................................1-221TIMER/COUNTER CURRENT VALUE CHANGE ...................................1-222TIMER/COUNTER SETTING CHANGE .................................................. 1-224RELAY ON/OFF .......................................................................................1-226WRITE INTO DATA MEMORY ................................................................1-227READ TRIMMER SETTING .....................................................................1-228SYNTAX CHECK .....................................................................................1-228PROGRAM CAPACITY CHECK ..............................................................1-229

6.4 Memory Card ................................................................................................1-2306.4.1 Functions [used with KV-P3E(01)] ..................................................................1-2306.4.2 Storage Capacity ............................................................................................1-230

CLEAR .....................................................................................................1-232NEW .........................................................................................................1-233ACCS .......................................................................................................1-234ACCS: SAVE ...........................................................................................1-235ACCS: LOAD ...........................................................................................1-236ACCS: VERIFY ........................................................................................1-236ACCS: DELETE .......................................................................................1-237

Chapter 7 KV-L2 Serial Interface Module KV-300

7.1 Outline .........................................................................................................1-2407.1.1 Features ..........................................................................................................1-240

7.2 Configuration ...............................................................................................1-2417.2.1 Parts and Functions ........................................................................................1-2417.2.2 System Configuration .....................................................................................1-2427.2.3 Outline of Operation Modes ............................................................................1-244

7.3 Installation ....................................................................................................1-2457.3.1 Setting the Operation Mode ............................................................................1-2457.3.2 Communications Protocols .............................................................................1-2477.3.3 Connector Wiring ............................................................................................1-248

Page 18: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

(17)

7.3.4 Connecting to External Units ..........................................................................1-249Connecting to An External Display ..........................................................1-249Connecting to an IBM PC-AT Computer ..................................................1-249Connecting to the KV-10/16/24/40/80 ......................................................1-250Connecting KV-L2s ..................................................................................1-250

7.4 Software Setup .............................................................................................1-2527.4.1 Using KV Software [KV IncrediWare (DOS)] ..................................................1-252Starting KV IncrediWare (DOS) from the KV-L2 ........................................................1-252

7.5 KV Mode Programming ...............................................................................1-2537.5.1 Operating in KV Mode ....................................................................................1-253

Communications protocol ........................................................................1-2537.5.2 Serial Communications Procedure .................................................................1-255

Command transmission procedure ..........................................................1-255Command/response format .....................................................................1-256Communications commands and responses ...........................................1-256Communications commands ....................................................................1-257

7.5.3 Transmission and Reception of Text Data ......................................................1-262Assigning relay nos. and data memory address nos. ..............................1-262Transmitting Text Data .............................................................................1-264Receiving text data ..................................................................................1-265ASCII code/binary conversion function ....................................................1-266Example program .....................................................................................1-269

7.6 Display Interface Mode Programming .......................................................1-2707.6.1 Operating in Display Interface Mode ..............................................................1-270

Communications protocols .......................................................................1-270Communications control procedure .........................................................1-271

7.6.2 Command and Response Format ...................................................................1-2737.6.3 Commands and Responses ...........................................................................1-275

List of commands and responses ............................................................1-275Description of commands and responses ................................................1-277End codes ................................................................................................1-291

7.7 Non-procedure Mode Programming ..........................................................1-2927.7.1 Operating in Non-procedure Mode .................................................................1-292

Communications protocol ........................................................................1-292Connecting to the KV-L2 ..........................................................................1-293

7.7.2 Assignment of Relay Nos. and Data Memory Address Nos. ..........................1-294Assigning relay nos. and data memory address nos. ..............................1-294

7.7.3 Transmitting Text Data ...................................................................................1-297Data transmission and internal data memory addresses .........................1-297

7.7.4 Receiving Text Data .......................................................................................1-298Format of received data and data memory addresses ............................1-298

7.7.5 ASCII code/Binary Conversion Function ........................................................1-300

7.8 Troubleshooting Guide ...............................................................................1-3047.8.1 Troubleshooting ..............................................................................................1-3047.8.2 Precautions .....................................................................................................1-305

7.9 Specifications ...............................................................................................1-3067.9.1 Specifications ..................................................................................................1-306

General specifications ..............................................................................1-306Communications protocol ........................................................................1-306RS-232C connector specifications ...........................................................1-306RS-422A terminal block specifications .....................................................1-306

7.9.2 Dimensions .....................................................................................................1-307

7.10 Command List ..............................................................................................1-3087.10.1 List of Commands and Responses .................................................................1-3087.10.2 List of Commands and Responses in Display Interface mode .......................1-309

Chapter 8 KV-AN6 Analog I/O Module KV-300

8.1 Outline .........................................................................................................1-312Features ...................................................................................................1-312

8.2 Configuration ...............................................................................................1-3138.2.1 Parts and Functions ........................................................................................1-3138.2.2 System Configuration .....................................................................................1-314

8.3 Installation ....................................................................................................1-3158.3.1 Terminal Nos. .................................................................................................1-315

Page 19: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

(18)

8.3.2 Removing the Terminal Block .........................................................................1-3168.3.3 Example of Voltage I/O Wiring ........................................................................1-3178.3.4 Example of Current I/O Wiring ........................................................................1-3188.3.5 Setting I/O Ranges .........................................................................................1-319

8.4 Programming ................................................................................................1-3208.4.1 Input Characteristics (A/D) ..............................................................................1-3208.4.2 Calculating Input Data (A/D) ...........................................................................1-3218.4.3 Output Characteristics (D/A) ...........................................................................1-3228.4.4 Calculating Output Data (D/A) ........................................................................1-3238.4.5 Assigning Data Memory (DM) Addresses .......................................................1-3248.4.6 Reading Analog Input .....................................................................................1-3258.4.7 Measuring Analog Input Average ...................................................................1-3268.4.8 Writing Analog Output .....................................................................................1-3278.4.9 Converting Analog Input to Analog Output .....................................................1-328

8.5 KV-AN6 Appendices ....................................................................................1-3298.5.1 Troubleshooting ..............................................................................................1-3298.5.2 Precautions .....................................................................................................1-3308.5.3 Specifications ..................................................................................................1-331

Environmental specifications ...................................................................1-331System specifications ..............................................................................1-331

8.5.4 Dimensions .....................................................................................................1-332

Chapter 9 KV-AD4/DA4 Analog I/O Unit KV-10/80

9.1 Outline .........................................................................................................1-334Features ...................................................................................................1-334

9.2 Configuration ...............................................................................................1-3359.2.1 Part Names and Functions .............................................................................1-335

KV-AD4 ....................................................................................................1-335KV-DA4 ....................................................................................................1-336

9.2.2 Specifications ..................................................................................................1-337KV-AD4 ....................................................................................................1-337KV-DA4 ....................................................................................................1-339

9.2.3 System Configuration .....................................................................................1-341

9.3 Installation ....................................................................................................1-3429.3.1 Installation Procedure .....................................................................................1-3429.3.2 Checking the Installation Environment ...........................................................1-3439.3.3 Setting the KV-AD4 Input Mode ......................................................................1-344

Setting the input mode .............................................................................1-3449.3.4 Connecting External Instruments ....................................................................1-345

Wiring .......................................................................................................1-345Wiring diagrams .......................................................................................1-346

9.3.5 Connecting to the KV-10 to 80 ........................................................................1-3489.3.6 Maintenance ...................................................................................................1-349

Inspection and Cleaning ..........................................................................1-349

9.4 Programming ................................................................................................1-3509.4.1 Programming the KV-AD4 ..............................................................................1-350

A/D Conversion Mechanism ....................................................................1-350About Digital Data after A/D Conversion .................................................. 1-351Calculating Voltage and Current Values from Digital Data ......................1-352

9.4.2 Programming the KV-DA4 ..............................................................................1-353D/A Conversion Mechanism ....................................................................1-353Converting Digital Data to Voltage or Current Values to be Output .........1-354Writing Digital Data to Data Memory for D/A Conversion ........................ 1-356

9.4.3 A/D and D/A Conversion Tables .....................................................................1-357Voltage Conversion Table ........................................................................1-357Current Conversion Table ........................................................................1-358

9.5 Programming Examples ..............................................................................1-359Calculating Analog Data Values from Digital Data ...................................1-359Writing Data to be Analog-output .............................................................1-361Outputting Analog Trimmer Values ..........................................................1-364Outputting Analog Input Data ...................................................................1-365Outputting Analog Input from a Pressure Sensor to an Air Valve ............ 1-366Setting the Minimum and Maximum Voltage Limits and Measuring theAverage Voltage ......................................................................................1-367

9.6 Troubleshooting ...........................................................................................1-370

Page 20: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

(19)

Chapter 10 Troubleshooting

10.1 Error List .......................................................................................................1-37210.1.1 List of Error Codes in Basic Units ...................................................................1-37210.1.2 Error indication in Expansion Units .................................................................1-37410.1.3 Program Errors ...............................................................................................1-37510.1.4 Memory Card Errors and Other Errors ...........................................................1-376

10.2 Replacing Relays .........................................................................................1-377Replacement procedure ...........................................................................1-377

10.3 Troubleshooting ...........................................................................................1-37810.3.1 Troubleshooting List .......................................................................................1-378

10.4 Error Messages ............................................................................................1-380

Appendices

Appendix A. Specifications and Dimensions [Visual KV Series] ....................1-382A.1 System Specifications [Visual KV Series] .......................................................1-382

Hardware .................................................................................................1-382Software and Programming .....................................................................1-383AC power supply unit ...............................................................................1-384

A.2 Common I/O Specifications of Basic Units .....................................................1-384Input specifications ..................................................................................1-384Output specifications (relay output): KV-10AR/DR, KV-16AR/DR,KV-24AR/DR, and KV-40AR/DR ..............................................................1-385Output specifications (transistor output): KV-10AT(P)/DT(P),KV-16AT(P)/DT(P), KV-24AT(P)/DT(P), and KV-40AT(P)/DT(P) ............1-385

A.3 Expansion Unit Specifications ........................................................................1-385A.4 Dimensions .....................................................................................................1-389

Appendix B. Specifications and Dimensions [KV-300 Series] .........................1-392B.1 System Specifications [KV-300 Series] ..........................................................1-392

Hardware .................................................................................................1-392Software and Programming .....................................................................1-393AC Power supply module/DC power distribution module ........................1-394

B.2 Module Specifications .....................................................................................1-398KV-300 CPU ............................................................................................1-398KV-C16X/C32X Input Modules ................................................................1-399KV-C32T/B16R/B16S Output Modules ...................................................1-400KV-R8X/R16X I/O Terminal Modules .......................................................1-401KV-R8T/R16T/R8R/R16R I/O Terminal Modules .....................................1-402KV-R8T/R16T/R8R/R16R I/O Terminal Modules (RUN Output) ..............1-403KV-R1A I/O Distribution Module ..............................................................1-403

B.3 Dimensions .....................................................................................................1-404

Appendix C. Ladder Program List ......................................................................1-406

Appendix D. A/D and D/A Conversion Tables [KV-AN6] .....................................1-408Voltage conversion table ..........................................................................1-408Current conversion table ..........................................................................1-409

WARRANTIES AND DISCLAIMERS 1-419

2 Support software

Chapter 1 Introduction

1.1 Items Included in the Package ........................................................................2-2

1.2 Outline of the Ladder Builder for KV ..............................................................2-31.2.1 Operating environment and system configuration ..............................................2-31.2.2 Features and functions of the Ladder Builder for KV ..........................................2-4

Features of the Ladder Builder for KV .........................................................2-4Functions of the Ladder Builder for KV ........................................................ 2-6

1.3 Before Programming .......................................................................................2-7Machines to be prepared .............................................................................2-7

1.3.1 Differences from the KV IncrediWare (DOS) ......................................................2-81.3.2 Differences from the Ladder Builder for KV Ver 1.0 ........................................... 2-8

1.4 Installing the Software .....................................................................................2-9

Page 21: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

(20)

1.4.1 Preparation for installation ..................................................................................2-91.4.2 Installation Procedure .......................................................................................2-10

Installation in Windows 95 .........................................................................2-10Installation in Windows 3.1 ........................................................................2-12

1.5 Cautions for Use ............................................................................................2-13

1.6 Basic Operations ...........................................................................................2-141.6.1 Program creation flow and available modes .....................................................2-141.6.2 Starting up and exiting from the software .........................................................2-161.6.3 Screen ..............................................................................................................2-181.6.4 Mouse operation and keyboard operation ........................................................2-211.6.5 Online Help .......................................................................................................2-23

Chapter 2 Editor KV-300

2.1 Outline of the Editor Functions ....................................................................2-262.1.1 Cautions for editing ladder programs ................................................................2-26

2.2 Edit Screen .....................................................................................................2-272.2.1 Name and function of each part of the screen ..................................................2-272.2.2 Ladder program window screen .......................................................................2-28

2.3 File Management ............................................................................................2-292.3.1 Creating a new file ............................................................................................2-292.3.2 Setting the automatic file read function .............................................................2-302.3.3 Setting automatic file save for the file ...............................................................2-312.3.4 Saving and reading files ...................................................................................2-322.3.5 Reading and saving a file in another format .....................................................2-332.3.6 Saving a ladder diagram in text format .............................................................2-362.3.7 Verifying files ....................................................................................................2-36

2.4 Entering/Deleting Symbols and Connection Lines ....................................2-372.4.1 Entering symbols ..............................................................................................2-372.4.2 Deleting symbols ..............................................................................................2-422.4.3 Entering contacts/coils directly .........................................................................2-422.4.4 Changing the device at the current cursor position ..........................................2-432.4.5 Entering/Deleting connection lines ...................................................................2-442.4.6 Canceling edit operations .................................................................................2-45

2.5 Entering Comments/Labels .........................................................................2-462.5.1 Editing comments/labels ...................................................................................2-462.5.2 Editing line comments .......................................................................................2-502.5.3 Changing ladder lines into comments ...............................................................2-51

2.6 Edit and Arrangement ..................................................................................2-522.6.1 Copy, move, and delete ....................................................................................2-522.6.2 Inserting and deleting lines ...............................................................................2-57

2.7 Jump, Search, and Replace .........................................................................2-582.7.1 Jump .................................................................................................................2-582.7.2 Searching for instruction words/operands ........................................................2-622.7.3 Searching for the device at the cursor position .................................................2-632.7.4 Replacing operands ..........................................................................................2-642.7.5 Converting a/b contacts ....................................................................................2-65

2.8 Editing the Mnemonic List ...........................................................................2-672.8.1 Displaying and terminating a mnemonic list .....................................................2-672.8.2 Copy, move, and delete ....................................................................................2-69

2.9 Displaying the Use Status .............................................................................2-702.9.1 Displaying a use status list ...............................................................................2-70

2.10 Setting the System .........................................................................................2-712.10.1 Setting the system ............................................................................................2-71

2.11 Entering and Developing Macros ................................................................2-722.11.1 Creating a macro file .........................................................................................2-722.11.2 Entering and developing macros ......................................................................2-74

2.12 Compilation ....................................................................................................2-752.12.1 Executing compilation .......................................................................................2-752.12.2 Error display ......................................................................................................2-762.12.3 Double coil check ..............................................................................................2-76

2.13 Printing Functions .........................................................................................2-77

Page 22: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

2.13.1 Printing ..............................................................................................................2-772.13.2 Preview display .................................................................................................2-81

2.14 Changing the Display Color on the Screen .................................................2-822.14.1 Changing display colors on the screen .............................................................2-82

Chapter 3 Simulator

3.1 Outline of the Simulator Functions ..............................................................2-843.1.1 Outline of the functions .....................................................................................2-843.1.2 Restrictions in the simulator ..............................................................................2-84

3.2 Starting up and Exiting from the Simulator .................................................2-863.2.1 Operating procedure for startup and exit ..........................................................2-863.2.2 Name and function of each part of the screen ..................................................2-88

3.3 Ladder Monitor ...............................................................................................2-893.3.1 Outline of the ladder monitor ............................................................................2-893.3.2 Executing scans ................................................................................................2-893.3.3 Executing steps ..............................................................................................2-1013.3.4 Jump and search ............................................................................................2-1053.3.5 Stop/reset and device all clear ........................................................................2-108

3.4 Monitor All ....................................................................................................2-1093.4.1 Outline of monitor all .......................................................................................2-1093.4.2 Displaying, saving, and reading the monitor all window .................................2-1093.4.3 Monitor all window ..........................................................................................2-1133.4.4 Registering devices ........................................................................................2-1133.4.5 Selecting and changing devices .....................................................................2-116

3.5 Registration Monitor ....................................................................................2-1193.5.1 Outline of the registration monitor ...................................................................2-1193.5.2 Displaying, saving, and reading the registration monitor ................................2-1193.5.3 Registration monitor window...........................................................................2-1223.5.4 Registering devices ........................................................................................2-1223.5.5 Selecting and changing devices .....................................................................2-1233.5.6 Manipulating timing charts ..............................................................................2-1283.5.7 Printing out the registration monitor ................................................................2-131

Chapter 4 Monitor

4.1 Outline of the Monitor Functions ...............................................................2-1344.1.1 Outline of the functions ...................................................................................2-1344.1.2 Restrictions in the monitor ..............................................................................2-1344.1.3 Precautions for communication ......................................................................2-135

4.2 Communicating with the PLC .....................................................................2-1364.2.1 Setting the PLC communication parameters ..................................................2-1364.2.2 Setting the comment transfer ..........................................................................2-138

4.3 Starting up and Exiting from the Monitor ..................................................2-1394.3.1 Operating procedures for startup and exit ......................................................2-1394.3.2 Name and function of each part of the screen ................................................2-143

4.4 Ladder Monitor .............................................................................................2-1444.4.1 Outline of the ladder monitor ..........................................................................2-1444.4.2 Displaying the ladder monitor window ............................................................2-1444.4.3 PLC error check ..............................................................................................2-1444.4.4 Starting the monitor ........................................................................................2-1454.4.5 Stopping the monitor .......................................................................................2-1454.4.6 Screen displayed while the monitor is running ...............................................2-1464.4.7 Setting the PLC operation mode .....................................................................2-147

4.5 Monitor All and Registration Monitor .........................................................2-1484.5.1 Functions of the monitor all window................................................................2-1484.5.2 Functions of the registration monitor ..............................................................2-148

4.6 Monitor Function ..........................................................................................2-1494.6.1 Disabling the input refresh/Disabling the output .............................................2-1494.6.2 Changing the current values all at once .........................................................2-1504.6.3 Device all clear ...............................................................................................2-154

(21)

Page 23: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

Appendices

Appendix A Error Message List .........................................................................2-156A-1 System errors .................................................................................................2-156A-2 Memory errors ................................................................................................2-156A-3 File errors ........................................................................................................2-157A-4 Installation errors ............................................................................................2-157A-5 Errors that occur in the editor .........................................................................2-158A-6 Errors that occur in the monitor/simulator .......................................................2-159A-7 Communication errors (displayed in the monitor) ........................................... 2-159A-8 PLC errors ......................................................................................................2-160A-9 Errors that occur during compilation ...............................................................2-161

Appendix B Instruction List ...............................................................................2-163B-1 Basic instructions ............................................................................................2-163B-2 Application instructions ...................................................................................2-164B-3 Arithmetic instructions .....................................................................................2-165B-4 Interrupt instructions .......................................................................................2-166

Appendix C Relay No. List ..................................................................................2-167C-1 Relays, timers, counters, and memory numbers for each model ...................2-167

Appendix D Special Utility Relay List ................................................................2-168D-1 Special relays and arithmetic operation flags ................................................. 2-168D-2 Special utility relays for high-speed counter (0) ..............................................2-168D-3 Special utility relays for high-speed counter (1) ..............................................2-169D-4 Other special utility relays ...............................................................................2-169D-5 Memory switches ............................................................................................2-172D-6 Special memory list .........................................................................................2-172

Appendix E Devices for KV-10R(W)/T(W) to 80R(W)/T(W), KV-300 ................ 2-174E-1 Special utility relays ........................................................................................2-174E-2 Memory switches ............................................................................................2-176E-3 Special memory list .........................................................................................2-176

Appendix F Sample Program List .....................................................................2-178F-1 Description of sample ladder programs ..........................................................2-178

Appendix G Quick Reference .............................................................................2-180G-1 Editor ..............................................................................................................2-180G-2 Simulator .........................................................................................................2-188G-3 Monitor ............................................................................................................2-195

Appendix H Notes for Programming .................................................................2-201H-1 Circuits that must be modified ........................................................................2-201H-2 Precautions for programming .........................................................................2-202H-3 Programs which cannot be decompiled ..........................................................2-203

Appendix I List of Files Used ............................................................................2-204

Appendix J Countermeasures for Frequent Communication Errors ............ 2-205

WARRANTIES AND DISCLAIMERS 2-215

(22)

Page 24: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

WARRANTIES AND DISCLAIMERSSee 3-367.

Caution• No part of this manual may be reprinted or reproduced in any form or by any

means without the prior written permission of KEYENCE CORPORATION.

• The content of this manual is subject to change without notice.

• KEYENCE has thoroughly checked and reviewed this manual. Please contactthe sales office listed at the end of this manual if you have any questions orcomments regarding this manual or if you find an error.

• KEYENCE assumes no liability for damages resulting from the use of the infor-mation in this manual, item 3 above notwithstanding.

• KEYENCE will replace any incomplete or incorrectly collated manual.

All company names and product names in this manual are registered trademarks ortrademarks of their respective owners.

(23)

Page 25: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

Chapter 1Programming

This chapter describes basic knowledge including program creation procedures,device configuration, relay assignments, special functions to set and confirm VisualKV Series operations, as well as the extended ladder diagrams. Understand thecontents described here completely at first before creating programs. For a detailed description of instructions, refer to "2.4. Instruction Details" (p.3-56).

1.1 Before Creating Programs .......................................................... 3-21.1.1 Flow from Introduction to Operation ........................................................... 3-21.1.2 Scan Time .................................................................................................. 3-3

1.2 User Memory ................................................................................ 3-41.2.1 Program Capacity ...................................................................................... 3-4

1.3 Device Configuration ................................................................... 3-51.3.1 Device List .................................................................................................. 3-51.3.2 Relay No. ................................................................................................... 3-71.3.3 Assigning Relay Nos. ................................................................................. 3-81.3.4 Input Relays ............................................................................................... 3-91.3.5 Output Relays .......................................................................................... 3-101.3.6 Internal Utility Relays ............................................................................... 3-111.3.7 Special Utility Relays ................................................................................ 3-121.3.8 Special Utility Relay List ........................................................................... 3-141.3.9 Timers and Counters ................................................................................ 3-181.3.10 Data Memories ......................................................................................... 3-191.3.11 Temporary Data Memory ......................................................................... 3-211.3.12 Relay Nos. and Functions ........................................................................ 3-22

1.4 Special Functions ...................................................................... 3-231.4.1 Input Time Constant Change Function .................................................... 3-231.4.2 Modifying the Input Relay Time Constant ................................................ 3-241.4.3 Constant Scan Time Mode....................................................................... 3-251.4.4 Output Disabled Function ......................................................................... 3-261.4.5 Input Refresh Disabled Function .............................................................. 3-261.4.6 Contact Comment Save Function ............................................................ 3-271.4.7 Special Functions ..................................................................................... 3-28

1.5 Extended Ladder Diagrams ...................................................... 3-291.5.1 Features of Extended Ladder Diagrams .................................................. 3-291.5.2 Advantages of Extended Ladder Diagrams ............................................. 3-301.5.3 Example of an Extended Ladder Diagram ............................................... 3-31

Page 26: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.1 Before Creating Programs

3-2

1

Chapter 1 Programming

1.1 Before Creating ProgramsThis section describes what you should know before creating programs and opera-tions for the Visual KV Series.

1.1.1 Flow from Introduction to OperationThis section describes an overview of program creation procedures, functions used,and setting items.In the example described below, a latch circuit is created as a program for the VisualKV Series.

Introduction

Examining contents of operationsFigure 1 shows a latch circuit which operates as follows.

Pushbutton switch PB1: ONPushbutton switch PB2: OFF

Pilot lamp (PL) turns on.

Pushbutton switch PB1: OFFPushbutton switch PB2: OFF

Pilot lamp (PL) remainslit even if PB1 turnsOFF.

Pushbutton switch PB1: OFFPushbutton switch PB2: ON

Pilot lamp (PL) goes outwhen PB2 is set to ON.

Time chartON

OFF

ON

OFF

PLON

OFF

PB1 contact

PB2 contact

Fig. 1PB1 = N.O. contact switchPB2 = N.C. contact switch

PB1 PB2

RL(Relay)

PL

Next, a program is created that will use the same operation as this circuit to control a PLC.

Program examinationCircuit 1 shows relay symbols for the latch circuit.Examine which contact in the Visual KV Series is used for each pushbutton switch and pilot lamp(Table 1). When many I/O devices are required for control, expansion units should also be considered.

Circuit 1

PL

RL

RL

RL

PB1 PB2Relay (coil)

Relay (contact)

Relay (contact)Pilot lamp

Table 1

I/O device Contact No.Pushbutton switch PB1 (N.O. contact) Input relay (0000)

Pushbutton switch PB2 (N.C. contact) Input relay (0001)

Relay RL Internal relay (1000)

Pilot lamp PL Output coil (0500)

Program creationEdit a program using the "LADDER BUILDER for KV" programming support software creation tool.

Ladder diagram

0500

1000

1000

1000

0000 0001*

Coding listLD 0000OR 1000AND 0001OUT 1000LD 1000OUT 0500END

* Enter "N.O. (AND X001)" to 0001 touse N.C. contact.

Transferring and confirming the programTransfer the created program to the Visual KV Series, perform a test run, and then confirm operationswith the actual devices.

Operation

Page 27: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.1 Before Creating Programs

3-3

11

Chapter 1 Programming

1.1.2 Scan TimeScan time

The Visual KV Series repeatedly executes a ladder based on the sequence circuitas follows.

The duration of time required to perform one cycle is called the scan time (or cycletime). The scan time varies based on program size and the instructions used in theprogram.

Input response time delayIn addition to the I/O processing time, there is also an input time delay in the VisualKV Series caused by the scan time. The input time delay is generated because theinput status can only be read during the input processing time. If the input status ischanged after input processing, the changed contents can only be read during thenext scan time.

In the figure below, 1 and 2 can be read but 3 cannot be read.

Reference: The maximum and minimum values of the input response time are asfollows.

Maximum value: Input time constant + Scan time x 2 + Output response delay time

Minimum value: Input time constant + Scan time + Output response delay time

Note 1: When the input time constant is made small by setting the HSP instruction,special utility relay 2813, and data memory DM1940, a signal may not be received ifits ON time is shorter than the scan time.

Note 2: The INT instruction is independent of the scan time.

Note 3: The minimum scan time is 140 µs (with the basic unit).

Input processing Writes the ON/OFF status of all input terminals to the inputmemory before executing the program.

Program execution

Reads the ON/OFF status of each device (internal utility relay,timer, counter, etc.) based on the instructions, and performsarithmetic operations.Writes the arithmetic operation result to the output memory.

Output processing Outputs the contents of the output memory to output terminals.

ON

OFF

1 2 3Input signal

Read Read

Out

put p

roce

ssin

g

Inpu

t pro

cess

ing

Programexecution

Scan time

Out

put p

roce

ssin

g

Inpu

t pro

cess

ing

Programexecution

Scan time

Out

put p

roce

ssin

g

Inpu

t pro

cess

ing

Programexecution

Out

put p

roce

ssin

g

Inpu

t pro

cess

ing

Programexecution

Out

put p

roce

ssin

g

Inpu

t pro

cess

ing

Page 28: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.2 User Memory

3-4

1

Chapter 1 Programming

1.2 User MemoryThis section describes the allowable size (capacity) of a program which can becreated in the Visual KV Series.

1.2.1 Program CapacityWhen a user program is created for the Visual KV Series, the maximum number ofsteps a program can contain using the mnemonic diagram varies based on the bytecount of the instructions used. The instruction byte count is determined individuallyfor each instruction. For more about byte counts for each instruction, refer to "2.1 Instruction List" (p.3-34).

Maximum number of lines in a programIn the KV-10xx/16xx, a program with approximately 2,000 steps can be written. Inthe KV-24xx/40xx, a program with approximately 4,000 steps can be written.

• Total byte count of the memory used by instructions ≤ 6,000 bytes / 12,000bytes

• Total byte count of the memory used by objects of instructions ≤ 12,000bytes / 24,000 bytes

* In the description above, a value on the left side indicates the byte count forthe KV-10xx/16xx, while a value on the right side indicates the byte count forthe KV-24xx/40xx.

* The memory occupied by objects indicates the memory required to execute aprogram when operation is started.

For example, the allowable number of steps to be written can be calculated from thememory occupied by the instructions as follows.

12,000 bytes / 3 bytes (average byte count of an instruction) = 4,000 steps

Note: If either the memory occupied by the instructions or the memory occupied byobjects of a program exceeds the specified memory capacity, the program cannotbe written or executed.

Calculating the byte count usedThe byte count used in this program can be calculated as shown in the table below.

T0000500

0000

0500

#00020T000

Line No. Instruction Operand Byte count Number of objects

00000 LD 0000 3 5

00001 OR 0500 3 4

00002 TMR 000#00020 2 7

00003 ANB T000 3 8

00004 OUT 0500 3 8

Total 14 bytes 32 bytes

Page 29: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.3 Device Configuration

3-5

11

Chapter 1 Programming

1.3 Device Configuration"Device" is a general name for relays, registers, etc. processed by instructions.This section describes the available devices in the Visual KV Series and theirgeneral use.

1.3.1 Device ListRelay list

Note 1: The ON/OFF status of the set functions is always cleared when the opera-tion mode is changed from PROGRAM to RUN. However, special utility relays 2700to 2715 are held even when the operation mode is changed from PROGRAM toRUN or when the power is turned off.

Note 2: Internal utility relays can be held by setting the MEMSW instruction

List of I/O relays in basic units

.oNyaleR esulamroNdeeps-hgiH

)1(esu)2(esudeeps-hgiH skrameR

0000syalertupnItupnitceriD(

)aeradewolla

stupnitpurretnI3TNIot0TNI

noisrevniytiraloP()dewolla

serutpactupnI

deeps-hgihfoesahpBsanoitcnufyehTnisyalerytilitufonoitacificepshguorhtsretnuoc

.01-VK1000

2000 –

3000 –

4000

syalertupnI

deeps-hgiHtupni0retnuoc

deeps-hgiH0retnuoc esahpA

tupni

5000deeps-hgiH

tupni1retnuocdeeps-hgiH

1retnuoc–

6000

deeps-hgiH0retnuoc esahpB

tupni

7000deeps-hgiH

1retnuoc–

8000deeps-hgiH

0retnuoc teserPtupni

9000deeps-hgiH

1retnuoc–

5140ot0100 syalertupnI –

0050

syalertuptuOtuptuotceriD()aeradewolla

tuptuo0retnuocdeeps-hgiH stniop07

1050deeps-hgiH

1retnuoctuptuo

ycneuqerfdeificepStuptuoeslup

2050 tuptuolortnocnwod/pu-pmaR –

3050 – –

5190ot4050 syalertuptuO stniop67

5191ot0001 syalerytilitulanretnI stniop061

5182ot0002 syalerytilitulaicepS stniop441

5192ot0092 syalerytilitulaicepS aeraegarotsnoitamrofniYEKH

51971ot0003 syalerytilitulanretnI stniop441,2

Model KV-10xx KV-16xx KV-24xx KV-40xx

Basic input relays 0000 to 0005 0000 to 0009 0000 to 0015 0000 to 0107

Basic output relays 0500 to 0503 0500 to 0505 0500 to 0507 0500 to 0515

Page 30: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.3 Device Configuration

3-6

1

Chapter 1 Programming

List of relays in expansion units Input units

Output units

I/O units

* Relay Nos. of expansion units are automatically assigned in the order of connection.* The connection order is counted only for input and output units. When I/O units are

connected, they are counted as input units and output units separately.

noitcennoCredro

X4E-VK X8E-VK X61E-VK

42/61/01-VK 04-VK 42/61/01-VK 04-VK 42/61/01-VK 04-VKtupnits1

eludom301ot001 302ot002 701ot001 702ot002 511ot001 512ot002

tupnidn2eludom

302ot002 303ot003 702ot002 703ot003 512ot002 513ot003

tupnidr3eludom

303ot003 304ot004 703ot003 704ot004 513ot003 514ot004

tupniht4eludom

304ot004 704ot004 514ot004

noitcennoCredro

R/)P(T4E-VK R/)P(T8E-VK R/)P(T61E-VK

tuptuots1eludom

306ot006 706ot006 516ot006

tuptuodn2eludom

307ot007 707ot007 517ot007

tuptuodr3eludom

308ot008 708ot008 518ot008

tuptuoht4eludom

309ot009 709ot009 519ot009

noitcennoCredro

)P(T/RX4E-VK

syalertupnI syalertuptuO

42/61/01-VK 04-VK 42/61/01-VK 04-VKtupnits1

eludom301ot001 302ot002

tupnidn2eludom

302ot002 303ot003

tupnidr3eludom

303ot003 304ot004

tupniht4eludom

304ot004

tuptuots1eludom

606ot306 606ot306

tuptuodn2eludom

307ot307 307ot307

tuptuodr3eludom

308ot308 308ot308

tuptuoht4eludom

309ot309 309ot309

Page 31: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.3 Device Configuration

3-7

11

Chapter 1 Programming

1.3.2 Relay No.The relay No. configuration is shown below.

Address No.Address Nos. are assigned to basic units, input expansion units, output expansionunits, and I/O expansion units. Zero to 4 are assigned to input units, while 5 to 9 areassigned to output units. Address Nos. assigned in a unit vary based on the numberof I/O terminals and the connection position of the unit.

* 2 to 4 in KV-40xx

Address No. assignment procedure• The address No. is represented as a number 0 to 9.• Address Nos. 0 to 4 are provided for inputs, while address Nos. 5 to 9 are pro-

vided for outputs.

1 2 5 1 5Channel No.

Contact No.(00 to 15)

Address No.(Input: 0 to 4, output: 5 to 9)

Model Address Nos.

KV-10xx 0, 5

Basic unitsKV-16xx 0, 5

KV-24xx 0, 5

KV-40xx 0, 1, 5

kV-E4X 1 to 4*

Input expansion units KV-E8X 1 to 4*

KV-E16X 1 to 4*

KV-E4R/E4T(P) 6 to 9

Output expansion units KV-E8R/E8T(P) 6 to 9

KV-E16R/E16T(P) 6 to 9

I/O expansion units KV-E4XR/E4XT(P) 1 to 4*, 6 to 9

Page 32: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.3 Device Configuration

3-8

1

Chapter 1 Programming

Contact No.• Contact Nos. are input/output terminal Nos. of basic units, input expansion units,

output expansion units, and I/O expansion units.

• The contact No. is represented as a number 0 to 15.

ExampleIn the KV-E4X, with 4 input terminals, the contact Nos. are 0 to 3. In the KV-E16T(P), with 16 input terminals, the contact Nos. are 0 to 15.

• In a unit with 16 or more terminals, the contact No. of the 17th terminal returns to0 and its address No. is increased by 1.

Example

In the KV-40AR, with 40 terminals (24 input and 16 output terminals), addressNo. 0 is assigned to input terminal Nos. 1 to 16 and address No. 1 is assigned toinput terminal Nos. 17 to 24

Channel No.The channel No. is the higher order digit in the contact No.

1.3.3 Assigning Relay Nos.When assigning relay Nos., the unit No. is based on the connection position of theunit, and the address No. is determined based on the unit type and I/O contacts.

With the connections above, the relay Nos. for each unit are assigned as shown inthe table below.

a) KV-16ARBasic unitInput: 10 pointsOutput: 6 points

b) KV-E4X InputexpansionunitInput: 4 points

c) KV-E8R Outputexpansion unitOutput: 8 points

Unit Assigned relay Nos.

a) KV-16AR 0000 to 0009 (input) and 0500 to 0505 (output)

b) KV-E4X 0100 to 0103 (input)

c) KV-E8R 01600 to 0607 (output)

Page 33: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.3 Device Configuration

3-9

11

Chapter 1 Programming

1.3.4 Input RelaysInput relays receive ON/OFF signals sent from external input equipment.

Note 1: Input relays function as contacts in programs. They cannot be used as relaycoils (outputs).

Note 2: There is no restriction of the contact type (N.O. or N.C.) used, the order therelay Nos. are used, or the number of relays used.

Basic unit Input relay time constant

Though the time constant is usually 10 ms ±20%, it can be changed using thefollowing settings.

• When the HSP instruction is used: 10 µs ±20%

• While special utility relay 2813 remains ON, the time constant can be changed in7 steps by setting data memory DM1940 as follows.

When DM1940 is set to 0: 10µs ±20%1: 20 µs ±20%2: 500 µs ±20%3: 1 ms ±20%4: 2.5 ms ±20%5: 5 ms ±20%6: 10 ms ±20%Never set a numeric value of 7 or larger.

For more about changing the input time constant, refer to "1.4.1 Input Time Constant ChangeFunction" (p.3-23).

Hardware input (independent of scan time)

• High-speed counterWhen the time constant is set to 10 µs using the HSP instruction or data memoryDM1940 (only while special utility relay 2813 remains ON), the maximum inputresponse of input relays 0004 and 0005 of CTH0 and CTH1 becomes 30 kHz.

• INT instruction: 0000 to 0003This instruction can receive any signal without regard to the scan time as far asthe signal ON time is longer than the input time constant.

"HSP instruction" (p.3-86), "INT instruction" (p.3-192), "4.1 High-speed Counter Instructions" (p.3-204)

Note 1: While special utility relay 2813 remains ON, the input time constant can bespecified for all input relays in a basic unit.

Note 2: Never enter a number of 7 or larger to data memory DM1940.

Note 3: The input time constant specified by data memory DM1940 becomeseffective at the rising edge of special utility relay 2813. To change the input timeconstant, first change data memory DM1940, then set special utility relay 2813 toOFF and ON again. Or change the operation mode of a KV basic unit from PRO-GRAM to RUN.

Note 4: If the HSP instruction and special utility relay 2813 are used at the sametime, priority is given to the HSP instruction.

Note 5: Only when a high-speed counter input or INT instruction is given, availableinput signals do not depend on the scan time.

Page 34: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.3 Device Configuration

3-10

1

Chapter 1 Programming

Expansion unit Input relay time constant

By setting special utility relays 2609 to 2612 to ON, the time constant in input expan-sion units can be set to 10 µs.

* Not available with the KV-40xx

1.3.5 Output RelaysOutput relays output the program execution results to the outside. There are twotypes of outputs, relay and transistor.

Note 1: Output relays function as contacts and relay coils in programs.

Note 2: There is no restriction of the contact type (N.O. or N.C.) used, the order therelay Nos. are used, or the number of relays used.

Output operation time• Transistor output

OFF ON: 50 µs or less (10 µs or less in 500 to 502)ON OFF: 250 µs or less (10 µs or less in 500 to 502, 100 µs or less for other

outputs in the basic unit)

• Relay outputOFF ON: 10 ms or lessON OFF: 10 ms or less

Note 1: When programming direct clock pulses, output relays 0500 and 0501 areused to output pulses in a transistor-type output unit.

Note 2: When the ramp-up/down control function is used, output relay 0502 outputspositioning pulses in a transistor-type output unit. "Chapter 5. Positioning Control" (p.3-253)

Note 3: When the specified frequency pulse output function is used, output relay0501 outputs pulses in a transistor-type output unit. "4.5.1 Specified Frequency Pulse Output Function" (p.3-228)

ytilitulaicepS.oNyaler

noitcnuF

*9062tinunoisnapxetupnifotnatsnocemittupnI

5110ot0010.soNyalerhtiw01:NO,sm01:FFO µs

0162tinunoisnapxetupnifotnatsnocemittupnI

5120ot0020.soNyalerhtiw01:NO,sm01:FFO µs

1162tinunoisnapxetupnifotnatsnocemittupnI

5130ot0030.soNyalerhtiw01:NO,sm01:FFO µs

2162tinunoisnapxetupnifotnatsnocemittupnI

5140ot0040.soNyalerhtiw01:NO,sm01:FFO µs

epyttuptuorotsisnarT epyttuptuoyaleR

)P(TD/)P(TA01-VK )P(TD/)P(TA61-VK RD/RA01-VK RD/RA61-VK

)P(TD/)P(TA42-VK )P(TD/)P(TA04-VK RD/RA42-VK RD/RA04-VK

T4E-VK )P(T8E-VK R4E-VK R8E-VK

)P(T61E-VK )P(TX4E-VK R61E-VK RX4E-VK

Page 35: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.3 Device Configuration

3-11

11

Chapter 1 Programming

1.3.6 Internal Utility RelaysIn a relay circuit, when one relay contact is used twice or more inside the circuit, amulti-pole relay with the same number of poles as the number used may be needed.Internal utility relays function only in programs, and eliminate the complexity of relaycircuits to facilitate circuit design.

Note 1: Internal utility relays function as contacts and relay coils in programs.

Note 2: There is no restriction of the contact type (N.O. or N.C.) used, the order therelay Nos. are used, or the number of relays used.

Retentive function of internal utility relaysExcept for internal utility relays, all relays turn OFF when the operation mode ischanged or when operation is stopped via a power shutdown. When operation isrestarted, all relays remain OFF except relays whose input condition is ON. How-ever, internal utility relays can be set using the MEMSW (memory switch) whether ornot they are to be retained. (Internal utility relays 2700 to 2715, however, are alwaysretained.)

When an internal utility relay is set to be retained, its ON/OFF status is stored even ifthe power is turned off. By using the retained relay all clear function (FUN65), allrelays which are set to be retained can be set to OFF. For more about setting the memory switch, refer to "MEMSW instruction" (p.3-92).

Application example of a retentive function: Lift vertical movement control

Internal utility relays 1000 and 1001 are set to be retained.When the upper/lower limit switch turns ON, the direction of lift movement isinverted. Even if the power is turned off while the lift is moving up (or down), the liftcontinues to move up (or down) when the power is turned on again.

Note: The retentive function is effective only when internal utility relays retained bythe self-retentive circuit or the SET/SFT/KEEP instruction are also retained by thememory switch.

Internal utility relays are not retained in the program shown below.

(0000)

(0500)

(0501)

(0001)

0000 10000001

T000 05000501

T001 05010500

1000 #00010T000

0001 10010000

1001 #00010T001

END

ENDH

MEMSW$0004

Move-up

Upper limitswitch

Lower limitswitch

Move-down

0000 1001

Page 36: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.3 Device Configuration

3-12

1

Chapter 1 Programming

1.3.7 Special Utility RelaysEach special utility relay has a unique function. By using special utility relays effec-tively, programs can be simplified and program control improved.

Note 1: A special utility relay can be used as many times as desired in one program.

Note 2: Special utility relays dedicated for reading can be used as contacts, butcannot be used as outputs.

For more about relays dedicated for reading, refer to "1.3.8 Special Utility Relay List" (p.3-14).

DescriptionRelay 2002: Always ONBy setting an output relay to ON using relay 2002, the output relay can be used as a"running indicator output".

Relay 2003: Always OFF.

Opposite that of relay 2002, use relay 2003 where it is not required to be turned on.For example, when using only the up function of an up/down counter, use relay 2003in the DW (down) input.

Relays 2004, 2005 and 2006: Clock pulse

For each relay, the time ratio is "ON:OFF = 1:1". (Accordingly, the ON time of relay2005 is 0.05 sec/pulse.)However, because these relays depend on the scan time, error as much as the scantime is generated.

• By combining an output relay, an "intermittent output" can be made.• By using relay 2006 as input for a counter, the counter can be used as a long-

term timer.

Relay 2007: Remains OFF during only one scan when operation is started.This relay can be used when a signal needs to be sent after a specific period(equivalent to one scan) after operation is started. This relay can also be used foran initial reset at the start of operation.After one scan, this relay remains ON.

2002

00000LDA

DM0000STA

2002

HSP0100

Set the input time constant of relay 0100 to 10 µs.Transfer the ON/OFF status data of channel 0000 to DM0000.

C000

1000 #03600

2006C000

1000

1000 turns ON at every hour.

1000 #00100

0000C005

2007

When operation is started, this relay returnsthe current value of C005 to 0.

Page 37: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.3 Device Configuration

3-13

11

Chapter 1 Programming

Relay 2008: Remains ON during only one scan when operation is started.

This relay can be used for an initial reset at the start of operation.After one scan, this relay remains OFF.

Relay 2813: Sets the input time constant of the CPU.While relay 2813 remains ON, the input time constant of a basic unit can be setusing the value of DM1940.

When operation is started, this relay sets all internalutility relays used by the SFT instruction to OFF.

0000

1000

SFTD

CLK

RES2008

1100

1100

#00000LDA

DM0000STA

2008

When operation is started, this relay returns the currentvalue of DM0000 to 0.

Page 38: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.3 Device Configuration

3-14

1

Chapter 1 Programming

1.3.8 Special Utility Relay ListSpecial relays and arithmetic operation flags

"1.3.7 Special Utility Relays" (p.3-12)

* Read-only relay.

Special utility relays for high-speed counter(0)

"Chapter 4. High-Speed Counters" (p.3-203)

* Read-only relay.

Note: Never use special utility relays that are not shown above.

.oNyaleR noitcnuF

*0012 1(0HTCrofylnodesukcolclanretnI µ )s*1012 01(0HTCrofylnodesukcolclanretnI µ )s*2012 001(0HTCrofylnodesukcolclanretnI µ )s

3012 0CTCrotarapmocnehw0HTCforaelccitamotuA.NOsnrut

deraelC:NOderaelctoN:FFO

4012 nehw0050ottuptuotceridstimrep/stibihorP.NOsnrut0CTCrotarapmoc

detibihorP:NOdettimreP:FFO

5012 rotarapmocnehwFFOottessi0050ottuptuotceriD.NOsnrut0CTC

FFOotteS:NOFFOottestoN:FFO

6012 rotarapmocnehwNOottessi0050ottuptuotceriD.NOsnrut0CTC

NOotteS:NONOottestoN:FFO

7012 hcaedesreversi0050ottuptuofosutatsFFO/NO.NOsnrut0CTCrotarapmocemit

desreveR:NOdesrevertoN:FFO

8012 nehw0050ottuptuotceridstimrep/stibihorP.NOsnrut1CTCrotarapmoc

detibihorP:NOdettimreP:FFO

9012 rotarapmocnehwFFOottessi0050ottuptuotceriD.NOsnrut1CTC

FFOotteS:NOFFOottestoN:FFO

0112 rotarapmocnehwNOottessi0050ottuptuotceriD.NOsnrut1CTC

NOotteS:NONOottestoN:FF

1112 hcaedesreversi0050ottuptuofosutatsFFO/NO.NOsnrut1CTCrotarapmocemit

desreveR:NOdesrevertoN:FFO

2112 1CTCrotarapmocnehw0HTCforaelccitamotuA.NOsnrut

deraelC:NOderaelctoN:FFO

3112 .0HTCrotarapmocrofedomnoitacilpitlumstceleSNOFFONOFFO

seslup2:NO4x:NO2x:FFOeslup1:FFO4112

noitacilpitluMedom

eslup1 2x 4x seslup2

3112 FFO NO FFO NO

4112 FFO FFO NO NO

.oNyaleR noitcnuF

*2002 .NOsyawlA

*3002 .FFOsyawlA

*4002 )%05:elcycytud(eslupkcolcs-10.0

*5002 )%05:elcycytud(eslupkcolcs-1.0

*6002 )%05:elcycytud(eslupkcolcs-0.1

*7002 .putratsretfanacstsrifgnirudFFOsniameR

*8002 .putratsretfanacstsrifgnirudNOsniameR

*9002nanehwroevitagensinoitarepocitemhtirafotlusernehwNOsnruT

.detarenegsiwolfrevo

*0102 .0sinoitarepocitemhtirafotlusernehwNOsnruT

*1102 .evitisopsinoitarepocitemhtirafotlusernehwNOsnruT

*2102 .rorrenasetarenegnoitarepocitemhtirananehwNOsnruT

Page 39: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.3 Device Configuration

3-15

11

Chapter 1 Programming

Special utility relays for high-speed counter(1)

"Chapter 4. High-Speed Counters" (p.3-203)

* Read-only relay.

Note: Never use special utility relays that are not shown above.

Other special utility relays

.oNyaleR noitcnuF

*0022 1(1HTCrofylnodesukcolclanretnI µ )s*1022 01(1HTCrofylnodesukcolclanretnI µ )s*2022 001(1HTCrofylnodesukcolclanretnI µ )s

3022 2CTCrotarapmocnehw1HTCforaelccitamotuA.NOsnrut

deraelC:NOderaelctoN:FFO

4022 nehw1050ottuptuotceridstimrep/stibihorP.NOsnrut2CTCrotarapmoc

detibihorP:NOdettimreP:FFO

5022 rotarapmocnehwFFOottessi1050ottuptuotceriD.NOsnrut2CTC

FFOotteS:NOFFOottestoN:FFO

6022 rotarapmocnehwNOottessi1050ottuptuotceriD.NOsnrut2CTC

NOotteS:NONOottestoN:FFO

7022 hcaedesreversi1050ottuptuofosutatsFFO/NO.NOsnrut2CTCrotarapmocemit

desreveR:NOdesrevertoN:FFO

8022 nehw1050ottuptuotceridstimrep/stibihorP.NOsnrut3CTCrotarapmoc

detibihorP:NOdettimreP:FFO

9022 rotarapmocnehwFFOottessi1050ottuptuotceriD.NOsnrut3CTC

FFOotteS:NOFFOottestoN:FFO

0122 rotarapmocnehwNOottessi1050ottuptuotceriD.NOsnrut3CTC

NOotteS:NONOottestoN:FFO

1122 hcaedesreversi1050ottuptuofosutatsFFO/NO.NOsnrut3CTCrotarapmocemit

desreveR:NOdesrevertoN:FFO

2122 3CTCrotarapmocnehw1HTCforaelccitamotuA.NOsnrut

deraelC:NOderaelctoN:FFO

3122 .1HTCrotarapmocrofedomnoitacilpitlumstceleSNOFFONOFFO

seslup2:NO4x:NO2x:FFOeslup1:FFO4122

noitacilpitluMedom

eslup1 2x 4x seslup2

3122 FFO NO FFO NO

4122 FFO FFO NO NO

.oNyaleR noitcnuF

0032 delbasidstuptuolanretxE)5190ot0050stuptuo(

delbasiD:NOdelbasidtoN:FFO

1032 delbasidstupnihserferlanretxE)5140ot0000stupni(

delbasiD:NOdelbasidtoN:FFO

3032 edomemitnacstnatsnoC)92MTnieulavteserpetirw(

delbanE:NOdelbasiD:FFO

4032 sdeecxeemitnacsnehwnacsenorofNOsniameR.emitnacstnatsnocteserp

5032 .noitareporetnuocycneuqerfrofgalftratS

6032 tuptuoeslupycneuqerfdeificepSdelbanE:NO

delbasiD:FFO7032 tuptuoeslupycneuqerfdeificepsrofgalfrorrE8032 .NOdenrutnehwrevirdrotomspotS

9032 nirevirdrotomspotS.noitareponisirevirdrotomnehwNOsnruT.noitcurtsnitpurretniybFFOdenrutnehwseicnegreme

0132 .)egdegnisirtanoitceted(NOdenrutnehwrevirdrotomstratS4132 .noitarepohctiwsmacrofgalftratS5132 .noitarepohctiwsmacnisruccororrenanehwNOsnruT

* Read-only relay.

Page 40: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.3 Device Configuration

3-16

1

Chapter 1 Programming

.oNyaleR noitcnuF

0042 langislanretxe0HTCfognimiTFFO teserplanretxE FFO

egdegnillaftANO

egdegnisirtANO

leveL1042 FFO desuton NO FFO NO

2042 TNIfoytiraloptpurretnIFFO

egdegnisirtAFFO

egdegnillaftANO

egdegnisirtANO

segdehtobtA3042 FFO NO FFO NO

4042 1TNIfoytiraloptpurretnIFFO

egdegnisirtAFFO

egdegnillaftANO

egdegnisirtANO

segdehtobtA5042 FFO NO FFO NO

6042 retnuocgnirsates0HTC teS:NO testoN:FFO

7042.edomnoitacilpitlumonottessi0HTCnehwtupniBesahperongI

.putnuocsyawladnatupniBesahperongI:NO.laususatupniBesahpesU:FFO

8042 teserplanretxe1HTCfognimiTFFO teserplanretxE FFO

egdegnillaftANO

egdegnisirtANO

leveL9042 FFO desuton NO FFO NO

0142 2TNIfoytiraloptpurretnIFFO

egdegnisirtAFFO

egdegnillaftANO

egdegnisirtANO

segdehtobtA1142 FFO NO FFO NO

2142 3TNIfoytiraloptpurretnIFFO

egdegnisirtAFFO

egdegnillaftANO

egdegnisirtANO

segdehtobtA3142 FFO NO FFO NO

4142 retnuocgnirsates1HTC teS:NO testoN:FFO

5142.edomnoitacilpitlumonottessi1HTCnehwtupniBesahperongI

.putnuocsyawladnatupniBesahperongI:NO.laususaBesahpesU:FFO

0052 .dengissasilenapecafretnirotarepo02D-VKno]1F[hctiwsdezimotsuC1052 .dengissasilenapecafretnirotarepo02D-VKno]2F[hctiwsdezimotsuC2052 .dengissasilenapecafretnirotarepo02D-VKno]3F[hctiwsdezimotsuC3052 .dengissasilenapecafretnirotarepo02D-VKno]4F[hctiwsdezimotsuC

4052silenapecafretnirotarepo02D-VKno1pmalrotacidnidezimotsuC

.dengissa

5052silenapecafretnirotarepo02D-VKno2pmalrotacidnidezimotsuC

.dengissa

6052silenapecafretnirotarepo02D-VKno3pmalrotacidnidezimotsuC

.dengissa

7052silenapecafretnirotarepo02D-VKno4pmalrotacidnidezimotsuC

.dengissa

8052rotareponeewtebegnahcstimreP02D-VKfoedomeciveddnaedom

.lenapecafretnirotarepodettimreP:NO

toN:FFOdettimrep

9052ecafretnirotarepo02D-VKehtstimreP

rotareponeewtebdetfihsebotlenap.edommetsysdnaedom

dettimreP:NOO toN:FF

dettimrep

0152ehtrofegaugnalyalpsidehtseificepS

lenapecafretnirotarepo02D-VKesenapaJ:NO hsilgnE:FFO

1152rotarepo02D-VKehtrofpeebehtsteS

lenapecafretnipeebesU:NO peeboN:FFO

2152 metsysrofdevreseR3152 metsysrofdevreseR

5152fostnetnoc(egassemresuasyalpsiD

wodniWsseccAehtni)0591MDyalpsiD:NO

egassemtonoD:FFO

egassemyalpsid

Page 41: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.3 Device Configuration

3-17

11

Chapter 1 Programming

Note: Never use special utility relays that are not shown above.

.oNyaleR noitcnuF

9062yalerhtiwtinunoisnapxetupnifotnatsnocemittupnI

5110ot0010.soNsm01:FFO

01:NO µs

0162yalerhtiwtinunoisnapxetupnifotnatsnocemittupnI

5120ot0020.soNsm01:FFO

01:NO µs

1162yalerhtiwtinunoisnapxetupnifotnatsnocemittupnI

5130ot0030.soNsm01:FFO

01:NO µs

2162yalerhtiwtinunoisnapxetupnifotnatsnocemittupnI

5140ot0040.soNsm01:FFO

01:NO µs

3162 tcennocsidnoisnapxetatupnifogniraelCderaelC:FFO

deraelctoN:NO

2172lamroN:FFOrorretcennocsiD

tinudetcennocninoitcennocsiD:NO

derotssiaerasihTehtnehwneve

siedomnoitarepomorfdegnahc

,NURotMARGORPsirewopehtnehwro

tuohtiw(ffodenrutehtybdetceffagnieb.)noitcurtsniWSMEM

tonsiaerasihTehtfinevederaelc

raelCllAyalerytilitu.detavitcasinoitcnufsiaerasiht,revewoH

llAnanehwderaelcdetucexesiraelC

agniretsigertuohtiw.margorp

4172tiucricnoitcerroctupnideeps-hgihfoesU

desutoN:FFOdesU:NO

5172 .noitareponisihctiwsmacelihwNO

0082 .)gnidneselihwNOsniamer(AtropnoitacinummocotdneslangiskaerB

1082ylnognirudNOsniamerdna,AtropnoitacinummocmorfatadtxetsevieceR

.atadtxetgniviecerelihwnacs1

2082ylnognirudNOsniameR.rorreecnatpeccaatadtxetAtropnoitacinummoC3082yalerro1082yalerrehtieelihwdeviecersiatadtxetnehwNOnacs1

.NOsi

3082rorreevieceratadtxetAtropnoitacinummoC

.sruccororreevieceratadtxetanehwnacs1ylnognirudNOsniameR4082 ).gnidnesgnirudNOsniamer(tratsdnesatadtxetAtropnoitacinummoC5082 .)gnidneselihwNOsniamer(BtropnoitacinummocotdneslangiskaerB

60821ylnognirudNOsniamerdna,atadtxetBtropnoitacinummocsevieceR

.atadtxetgniviecerelihwnacs

7082.rorreecnatpeccaatadtxetBtropnoitacinummoC

elihwdeviecergniebsiatadtxetnehwNOnacs1ylnognirudNOsniameR.NOsi8082yalerro6082yaler

8082rorreevieceratadtxetBtropnoitacinummoC

.sruccororreevieceratadtxetanehwnacs1ylnognirudNOsniameR9082 ).gnidnesgnirudNOsniamer(tratsdnesatadtxetBtropnoitacinummoC2182 .yrettabpukcabhtiwsruccoytilamronbananehwNOsnruT

3182

ybdesustupnitpecxe(eludomcisabnistupnillaottnatsnocemittupnisteS.)noitcurtsniPSH

.sm01ottnatsnocemittupnisteS:FFO.tnatsnocemittupnisenimretedneht,0491MDniderotseulavotsrefeR:NO

4182 .detibihorperasyekelpitluM:noitcurtsniYEKH5182 .dehsinifsinacS:noitcurtsniYEKH

5192ot0092 .aeraegarotsnoitamrofniYEKH

Page 42: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.3 Device Configuration

3-18

1

Chapter 1 Programming

1.3.9 Timers and CountersTimers and counters can be set in a program, and their outputs can be used ascontacts elsewhere in the program. [There is no restriction on the contact type (N.O.or N.C.) and the order of use.]A same number can be assigned to only one timer or counter. For example, T005and C005 cannot be used in the same program.

Timer/Counter list

Description Timers• When 0.1-s timers (TMR) and high-speed 0.001-s timers (TMS) are used as

contacts, the "Tnnn" No. is used for both types. However, the form for setting isdifferent. "TMRnnn#ddddd" is used for 0.1-s timers, "TMHnnn#ddddd" is used forhigh-speed 0.01-s timers, and "TMSnnn#ddddd" is used for high-speed 1-mstimers (nnn = timer No, ddddd = timer set value).

• In a single program, different timer Nos. must be assigned to each of TMRnnn,TMHnnn, and TMSnnn.

• When the PLC is stopped, all timers are reset and their current values becomeequivalent to set values.

Counters• When counters (C) and up/down counters (UDC) are used as contacts, the

"Cnnn" No. is used for both types. However, the form for setting is different."Cnnn#ddddd" is used for counters, while "UDCnnn#ddddd" is used for up/downcounters.

• In one program, different numbers must be assigned to each of the counters andup/down counters.

• Even when operation is stopped, each counter stores whatever value it has atthat time.

"TMR instruction" (p.3-67), "TMH instruction" (p.3-68), "TMS instruction" (p.3-69), "C instruction" (p.3-72), "UDC instruction" (p.3-76).

High-speed counters and high-speed counter comparators

The Visual KV Se ries is equipped with two high-speed counters (CTH0 and CTH1)and four high-speed counter comparators (CTC0, CTC1, CTC2, and CTC3) with a30-kHz input response speed (frequency), two phases, and size of 16 or 24 bits.

Note: When a high-speed counter or high-speed counter comparator will be used asa 24-bit device, a set value is required to be stored in a data memory using theMEMSW instruction.

For details about high-speed counters and high-speed counter comparators, refer to "Chapter 4 High-speed Counters" (p.3-203).

emaN tcatnoClioC

)noitcurtsni(rebmuN

remiT

)remits-1.0(remiT

942Tot000T

942ot000RMT

latotni052

remitdeeps-hgiH)remits-10.0(

942ot000HMT

remitsm-1deeps-hgiH)remits-100.0(

942ot000SMT

retnuoCretnuoC

942Cot000C942ot000C

retnuocnwod/pU 942ot000CDU

Page 43: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.3 Device Configuration

3-19

11

Chapter 1 Programming

1.3.10 Data MemoriesData memories store various types of data.Data memories are not usually used in a program that consists of contacts, coils,timers, and counters. When arithmetic instructions are used, however, data memo-ries can be used to store data for arithmetic operations as well as the results ofarithmetic operations.

.oNMD noitpircseD

999MDot0MD )resuybdesuebnac(deificepstoN

9901MDot0001MD AtropeviecertxeT

9911MDot0011MD AtropdnestxeT

9921MDot0021MD BtropeviecertxeT

9931MDot0031MD BtropdnestxeT

0041MD .oNyalertuptuotsrifehT:noitcnufhctiwsmaC

1041MD rotarapmocpets-itlumnieulavnosirapmoC:noitcnufhctiwsmaCedom

2041MD tupnitnempiuqefoelcycenofotnuocesluP:noitcnufhctiwsmaC0HTCot

3041MD )resuybdesuebnac(deificepstoN

4041MD )sm(elcyctnemerusaeM

5041MD )zH(tnuocycneuqerffotluseR

7041MD/6041MD yalertuptuohcihwtaelgnafoeulavteS:noitcnufhctiwsmaCFFO/NOsnrut

9041MD/8041MD:

9641MD/8641MD

1+yalertuptuohcihwtaelgnafoeulavteS:noitcnufhctiwsmaCFFO/NOsnrut

:13+yalertuptuohcihwtaelgnafoeulavteS:noitcnufhctiwsmaC

FFO/NOsnrut

0741MD )resuybdesuebtonnac(metsysybdevreseR

9741MDot1741MD )resuybdesuebnac(deificepstoN

0841MD ot002()zH(ycneuqerfputratS:noitcnuflortnocnwod/pu-pmaR)000,05

1841MD ot002()zH(ycneuqerfgnitarepO:noitcnuflortnocnwod/pu-pmaR)000,05

2841MD )sm(emitnoitareleccA:noitcnuflortnocnwod/pu-pmaR)000,4ot0(

3841MD )resuybdesuebnac(deificepstoN

4841MD )tigidrewol(tnuocesluptuptuO:noitcnuflortnocnwod/pu-pmaR)535,56ot0(

5841MD )tigidreppu(tnuocesluptuptuO:noitcnuflortnocnwod/pu-pmaR)535,56ot0(

6841MD )71ot11(edocrorrE:noitcnuflortnocnwod/pu-pmaR

9941MDot7841MD )resuybdesuebnac(deificepstoN

9651MDot5651MD )resuybdesuebnac(deificepstoN

9751MDdna8751MD )resuybdesuebnac(deificepstoN

9951MDot0851MD .oNecivedyalpsiD:lenapecafretnirotarepO02D-VK

9961MDot4661MD )resuybdesuebnac(deificepstoN

5761MDot0761MD )resuybdesuebtonnac(metsysybdevreseR

6761MD gnittesnoissimreptfihsneercS:lenapecafretnirotarepO02D-VKedomrotareponi

Page 44: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.3 Device Configuration

3-20

1

Chapter 1 Programming

* Read-only relay.

Note 1: 16-bit binary data is stored in each of the data memories as for internalregisters.

Note 2: The data stored in data memories is held even when the power is turned offor when the All Clear function is executed. The backup time is 20 days or more inthe KV-10xx, and 2 months or more in other models.

Note 3: DM1000 to DM1999 are assigned as special data memories.

.oNMD noitpircseD

9761MDot7761MDecafretnirotarepo02D-VKehtrofedomsseccatceridrofaerA

lenap

9961MDot0861MD setubirttaecivedyalpsiD:lenapecafretnirotarepO02D-VK

9971MDot4671MD )resuybdesuebnac(deificepstoN

9081MDot6081MD )resuybdesuebnac(deificepstoN

9981MDot6281MD )resuybdesuebnac(deificepstoN

*1091MD/0091MD )tigidreppu/tigidrewol(0HTCmorfdaereulavtib-42

*3091MD/2091MD )tigidreppu/tigidrewol(1HTCmorfdaereulavtib-42

*5091MD/4091MD )tigidreppu/tigidrewol(0CTCmorfdaereulavtib-42

*7091MD/6091MD )tigidreppu/tigidrewol(1CTCmorfdaereulavtib-42

*9091MD/8091MD )tigidreppu/tigidrewol(2CTCmorfdaereulavtib-42

*1191MD/0191MD )tigidreppu/tigidrewol(3CTCmorfdaereulavtib-42

3191MD/2191MD )tigidreppu/tigidrewol(0HTCotnettirweulavtnerructib-42

5191MD/4191MD )tigidreppu/tigidrewol(1HTCotnettirweulavtnerructib-42

7191MD/6191MD )tigidreppu/tigidrewol(0CTCotnettirweulavtnerructib-42

9191MD/8191MD )tigidreppu/tigidrewol(1CTCotnettirweulavtnerructib-42

1291MD/0291MD )tigidreppu/tigidrewol(2CTCotnettirweulavtnerructib-42

3291MD/2291MD )tigidreppu/tigidrewol(3CTCotnettirweulavtnerructib-42

5291MD/4291MD )tigidreppu/tigidrewol(tupniteserp0HTC

7291MD/6291MD )tigidreppu/tigidrewol(tupniteserp1HTC

*9291MD/8291MD )tigidreppu/tigidrewol(detarenegsi0TNInehwerutpactupnI

*1391MD/0391MD )tigidreppu/tigidrewol(detarenegsi1TNInehwerutpactupnI

*3391MD/2391MD )tigidreppu/tigidrewol(detarenegsi2TNInehwerutpactupnI

*5391MD/4391MD )tigidreppu/tigidrewol(detarenegsi3TNInehwerutpactupnI

6391MD )zH(ycneuqerfteS:noitcnuftuptuoeslupycneuqerfdeificepS

7391MD noitamrofninoitcennoctinunoisnapxeO/I

8391MD eulavtimilreppU:0.oNremmirtlatigiD

9391MD eulavtimilreppU:1.oNremmirtlatigiD

0491MD

gnittestnatsnocemittupnI01:0 µ 02:1s µ 005:2s µs

sm01:6sm5:5sm5.2:4sm1:3.tesebtonnaceulavrehtoynA

3491MDot1491MD )resuybdesuebtonnac(metsysybdevreseR

4491MDnoisividnehwnacs1otnidetrevnocsnoitcurtsniforebmuN

demrofrepsinoisrevnoc

9491MDot5491MD )resuybdesuebnac(deificepstoN

0591MD )552ot0(yalpsidrorrewodniwsseccA

9991MDot1591MD )resuybdesuebnac(deificepstoN

Page 45: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.3 Device Configuration

3-21

11

Chapter 1 Programming

1.3.11 Temporary Data MemoryThese data memories are used for temporary storage. When arithmetic instructionsare used, temporary data memories can be used to temporarily store the data forarithmetic operations as well as the results of arithmetic operations.

Attribute R: Read W: Write

* Both R and W are enabled when special functions are not used.

Note 1: Temporary data memories are initialized when the power is turned on.

Note 2: TM20, TM30, and TM31 are read-only, so cannot be used for writing.However, TM28 can be used for both reading and writing if special functions are notused.

Note 3: TM00 and TM01 are used by the MUL and DIV instructions. Never use themfor any other purpose.

.oNMT egasU etubirttA

00MT )LUM/VID(snoitarepocitemhtirarofdesU W/R

10MT )VID(snoitarepocitemhtirarofdesU W/R

72MTot20MT )resuybdesuebnac(deificepstoN W/R

82MTelihweulavtesdnoyeb)sm1:eludom(emitnacsserotS

.demrofrepsinoitarepoemitnacstnatsnoc*R

92MTemitnacstnatsnocfo)sm1:eludom(eulavtesserotS

noitarepoW/R

03MT .nevigsinoitpurretni3TNInehweulav0CTCserotS *R

13MT01yrevefoeulavnaem(emitnacsderusaemserotS

.)sm1.0:eludom()snacsR

Page 46: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.3 Device Configuration

3-22

1

Chapter 1 Programming

1.3.12 Relay Nos. and FunctionsAssignment of Relay Nos.The components of a relay no. are shown below.

Unit Nos.

Unit nos. are assigned to units within the KV-300 system, with the unit connected tothe right of the KV-300 CPU (see the figure below) assigned as no. 7. The CPU isassigned as unit no. 0.

Address Nos.

Address nos. are assigned to the input units, output units, and I/O terminal units.The following table shows the assignment of address nos. to units.

* The KV-R1A I/O Distribution Unit accommodates 5 input units and 5 output units.Addresses are set with address switches.

0 7 5 1 5

Address No.

Channel No. Relay No. (00 to 15)

Module No. (07 to 17)Input (0 to 4) Output (5 to 9)

Power supply unit CPU

0 7 8 9 16 17

Unit Address No.

KV-300 CPU CPU 0, 5

KV-C16X 16-input unit 0

KV-C32X 32-input unit 0. 1

KV-B16R 16-output unit 5

KV-B16S 16-output unit 5

KV-C32T 32-output unit 5, 6

KV-R8X 8-input terminal unit 0 to 4 *

KV-R16X 16-input terminal unit

KV-R8R 8-output terminal unit 5 to 9 *

KV-R16R 16-output terminal unit

KV-R8T 8-output terminal unit

KV-R16T 16-output terminal unit

Page 47: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.4 Special Functions

3-23

11

Chapter 1 Programming

1.4 Special FunctionsThis section describes special functions to set and confirm operations on the VisualKV Series, and useful functions for program debugging and adjustment of externalequipment.

1.4.1 Input Time Constant Change FunctionThe input time constant can be changed when a signal is read from an input contact.When connecting external equipment which has no contact in which chattering suchas transistor outputs does not occur, and inputting pulses of short width, the inputtime constant change function can be used to decrease the input time constant.

Setting the input time constant for basic units using special utility relaysThe input time constant for a basic unit can be changed using data memory DM1940and special utility relay 2813.Though the input time constant is usually 10 ms, it can be changed to a value thatcorresponds to the number stored in DM1940 by setting special utility relay 2813 toON.If the HSP instruction and special utility relay 2813 are used at the same time,priority is given to the HSP instruction and the number stored in DM1940 is ignored.

Special utility relay 2813OFF: Sets the input time constant to 10 ms.ON: Refers to the number stored in DM1940, then determines the input time

constant.

Note 1: Be sure to set the input time constant to 10 µs when using the 30-kHz high-speedcounter input.

Note 2: Never enter a number that is 7 or larger to data memory DM1940.

Note 3: The input time constant specified by data memory DM1940 becomes effective at therising edge of special utility relay 2813.

To change the input time constant, first change data memory DM1940, then set special utilityrelay to OFF and ON again. Or change the operation mode of the KV basic unit fromPROGRAM to RUN.

Note 4: The input time constant for input relays set by the HSP instruction is 10 µs.

For more about the HSP instruction, refer to "HSP instruction" (p.3-86).

For more about setting the input time constant for expansion units, refer to "Input timeconstant for expansion units" (p.1-76).

Note 5: Set the special utility relay using the SET/RES instructions.

Note 6: When the input time constant is set to 1 ms or less, connect the output equipmentwithout contacts. If connecting output equipment with contacts, contact bounds may enter.

Note 7: Except for interrupts and high-speed counters, signals whose ON time is shorter thanthe scan time may not be received even if the input time constant is set to a small value.

0491MDniderotsrebmuN tnatsnocemittupnI0 01 µs1 02 µs2 005 µs3 sm14 sm5.25 sm56 sm01

eromro7 dewollatoN

Page 48: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.4 Special Functions

3-24

1

Chapter 1 Programming

1.4.2 Modifying the Input Relay Time Constant Modifying with External Switches

KV-C32X/C16X KV-R16X/R8X

As shown in above figures, an external switch can be used to select the input timeconstant only on the KV-C32X/C16X Connector Input Units and KV-R16X/R8X I/OTerminal Units.

In the following table, white represents the switch position.

Note: Connect a solid-state contact output device when the input time constant isset to 1 ms for 25 µs. Connection of a contact output device may result in contactbounce.

Modification within the CPUThe input time constant for KV-300 CPU input relay nos. 0000 to 0009 can bemodified in the program.

Note 1: When using the 30 kHz high-speed counter input, turn ON special utilityrelay 2813.

Note 2: When special utility relay 2813 is ON, the input time constant of input relays0000 to 0009 is set to 10 µs ±20%.

Note 3: The input time constant remains 10 ms ±20% if the HSP instruction is usedwhen special utility relay 2813 is ON.

Note 4: When the input time constant is set to 10 µs or 25 µs, a solid-state outputdevice must be connected. Connection of a contact output device may result incontact bounce.

5V24V 10 ms0 ms1 ms

43

2

10

1 ms0 ms 10 ms

Input time constant selection switch

Input time constant KV-C32X/C16X KV-R16X/R8X

25 µs ±20%

1 ms ±20%

10 ms ±20%

0ms 1ms 10ms

0ms 1ms 10ms

0ms 1ms 10ms

0ms 1ms 10ms

0ms 1ms 10ms

0ms 1ms 10ms

Input time constant Setting

10 µs ±20% Turn ON special utility relay 2813 (0000 to 0009).

25 µs ±20% Use the HSP instruction.

10 ms ±20% Default

KV-300 PLC Only

Page 49: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.4 Special Functions

3-25

11

Chapter 1 Programming

1.4.3 Constant Scan Time ModeThis function executes a program while keeping the scan time at a constant valuewhich usually changes based on the processing contents. This section describeshow to set this function.

Though the scan time changes usually depending on the processing contents, it canbe kept at a constant value by using this function. This function can be used toacquire data from external equipment at a constant time interval.The set value should be longer than the maximum scan time because the scan timeis kept at a constant value until the end of processing.

Setting procedureSet the desired scan time to temporary data memory TM29.Set special utility relay 2303 to ON.The scan time is written to TM31.The scan time can be set in 1-ms increments.Enter the desired scan time (ms) to the temporary data memory.

Setting example

In this example, the scan time is kept at 20 ms.

Note 1: Be sure to set the constant scan time value so it is larger than the actualscan time.

Note 2: If the actual scan time exceeds the set scan time, special utility relay 2304turns ON (during the next 1 scan) while the actual scan time is written to TM28 (unit:1 ms).

Note 3: The scan time can be set up to 200 ms in temporary data memory TM29. Ifa value larger than 200 ms is input, it will be treated as 200 ms.

2008 2303SET

TM29STA

#00020LDA

Page 50: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.4 Special Functions

3-26

1

Chapter 1 Programming

1.4.4 Output Disabled FunctionThis function disables outputs from each unit in RUN mode without regard to theprogram used. By disabling external outputs, the program can be debugged whileexternal equipment is connected, even when output of signals to the externalequipment is not desired.

Setting procedureWhen special utility relay 2300 turns ON, all outputs from all output relays (0500 to0915) to the outside are cleared after 1 scan is finished.However, the display in the Access Window and the output indicator lamps are notcleared.

Setting example

By setting/resetting special utility relay 2300 using the Access Window, the "KVIncrediWare (DOS)" or "LADDER BUILDER for KV" programming support software,or the KV-P3E(01) handheld programmer, the external output prohibition functioncan be used.External outputs are prohibited while input 0000 is ON. External outputs are permit-ted, though, while input 0000 is OFF.

For more about operating procedures, refer to the "Chapter 6. Handheld Programmer" (p.1-195).

1.4.5 Input Refresh Disabled FunctionThis function disables the update of inputs from each unit triggered by input signalsfrom external equipment.By disabling external input refresh, inputs from each unit can be set to ON/OFF inmonitor status without mechanical operations to enable a program check.

Setting procedure

When special utility relay 2301 turns ON, input refresh (read of input relays) for allinput relays (0000 to 0415 used by the QL Series) is skipped.In this status, inputs can be set to ON/OFF from the Access Window, the "KVIncrediWare (DOS)" or "LADDER BUILDER for KV" programming support software,or the KV-P3E(01) handheld programmer.

Setting exampleBy setting/resetting special utility relay 2301 using the Access Window, the "KVIncrediWare (DOS)" or "LADDER BUILDER for KV" programming support software,or the KV-P3E(01) handheld programmer, the external input refresh prohibitionfunction can be used.External input refresh is prohibited while input 0000 is ON. External input refresh ispermitted, though, while input 0000 is OFF.

For more about operating procedures, refer to the "Chapter 6. Handheld Programmer" (p.1-195).

Note: Once external input refresh is prohibited, it can be permitted only by settingspecial utility relay 2301 to OFF from the Access Window, the "KV IncrediWare(DOS)" or "LADDER BUILDER for KV" programming support software, or the KV-P3E(01) handheld programmer.

0000 2300

0000 2301

Page 51: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.5 Extended Ladder Diagrams

3-27

11

Chapter 1 Programming

1.4.6 Contact Comment Save Function• This function transfers contact comments to the Visual KV Series using the "KV

IncrediWare (DOS)" or "LADDER BUILDER for KV" programming supportsoftware.

• The Visual KV Series can store not only programs but also comments registeredto each contact using the "KV IncrediWare (DOS)" or "LADDER BUILDER forKV" programming support software.A program may not be easy to understand if only device Nos. are used. Byregistering comments to the contacts, the program can be easily debugged andmore efficiently maintained.

• The number of contact comments that can be transferred is up to 1,000 for bothnormal transfer and compression transfer.

• The KV-D20 operator interface panel includes the contact comment displayfunction.

For more about operating procedures, refer to "2.5 Entering Comments/Labels" (p.1-46) and "4.2.2Setting the comment transfer" (p.2-138).

Note 1: Line comments cannot be stored.

Note 2: The KV-P3E(01) handheld programmer cannot read or write contact com-ments.

Note 3: The KV-D20 operator interface panel cannot display contact commentswhich have been compressed and transferred.

Page 52: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.4 Special Functions

3-28

1

Chapter 1 Programming

1.4.7 Special FunctionsConstant Scan Time Mode

In this mode, operation can take place according to a preset scan time (in ms).

Setting

Write the desired scan time into TM29 (temporary data memory), then turn onspecial utility relay No. 2303. The scan time can also be written into TM31. Specify ascan time in increments of 10 ms (a value of less than 10 ms is invalid).Here, write a value into TM equivalent to 10 times the scan time.

ExampleSet the constant scan time to 20 ms.

Note 1: The set value for the constant scan time must be greater than the actualscan time. Otherwise, special utility relay 2304 turns on during every scan to disableconstant scan time mode.

Note 2: If the scan time exceeds the set value, special utility relay no. 2304 turns onduring the next scan.

Output Disabled FunctionDuring checking of a program, this function clears output from output relays regard-less of the program currently running.

SettingTurn on special utility relay No. 2300. After one scan is completed, all output relays(00500 to 00503, 07500 to 17915) are cleared.

Example

Use the output disabled function by executing FORCED RESET/RESET to specialutility relay No. 2300 from the monitor display. To execute FORCED RESET or RESET, refer to "Chapter 6 Handheld Programmer" (p.1-195).

Input Refresh Disabled FunctionSet this function if it is desired to turn ON/OFF input relays from the monitor displaywithout activating the machine when checking a program.

Setting

Turn ON special utility relay No. 2301 to skip input refresh (reading from inputrelays). Input relays can then be turned ON/OFF with the KV-P3E(01) or with KVIncrediWare (DOS) on the monitor display.

Example

Set input relay No. 0000 to ON to disable input refresh; set to OFF to enable inputrefresh.

Note: If input refresh is disabled, it is not enabled until input relay No. 0000 is turnedon from the handheld programmer.

LDA STA SET

02008 #00200 TM29 2303

0000 2301

KV-300 PLC only

Page 53: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.5 Extended Ladder Diagrams

3-29

11

Chapter 1 Programming

1.5 Extended Ladder DiagramsThis section describes KEYENCE’s unique extended ladder diagram.

1.5.1 Features of Extended Ladder DiagramsThe extended ladder diagram is a programming method developed to reduceproblems related to design, testing, operation, and maintenance of programs.In a conventional ladder diagram, output instructions can be written only on the rightside of a ladder diagram. On the other hand, in an extended ladder diagram, outputinstructions can be written anywhere except on the left. As the result, the programsshown below can be written.

Mixture of input and output circuits

Conventional ladder diagram Extended ladder diagram

Connection of two or more instructions on one line

Conventional ladder diagram Extended ladder diagram

Branch from output coil

Conventional ladder diagram Extended ladder diagram

Only input circuitscan be written.

Only outputcircuits canbe written.

Only inputcircuits canbeassembled.

Both inputcircuits andoutput circuitscan beassembled.

Only outputcircuits canbeassembled.

Instructions can be written only from theleft end to the right end on one line.

Many instructions can be connected.

There is only a single line, so the ladderdiagram is easier to understand.

Branches can be made only from inputcontacts.

Three lines are required.

Branches can also be made from outputcoils.

Page 54: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.5 Extended Ladder Diagrams

3-30

1

Chapter 1 Programming

2010

20102002

2010 0502

0501

0500#01000CMP

DM0000LDA

#02000CMP

#03000CMP

2002 DM0000LDA

#01000CMP

2002

2010

#02000CMP

0500

0501

2002

2010

#03000CMP

2010 0502

In a conventional ladder diagram, operationsperformed by the program cannot be easilyunderstood. In an extended ladder diagram,operations performed by the program can beunderstood at a glance.

When the start switch (0000) is set to ON, a lamp (0500) is lit andtimer 0 is activated.

0000 1100

T000

T001

0500

0501

0502 0000

1000STG

1001STG

#00030T000

#00020T001

1002STG

1001JMP

1002JMP

ENDS

1100DIFU

1000SET

When timer 0 turns ON three seconds later, the lamp goes out, abuzzer (0501) is sounded, and timer 1 is activated.

When timer 1 turns ON two seconds later, the buzzer is stoppedand the motor (0502) starts to rotate.

When the start switch (0000) is set to OFF, the motor is stoppedand all operations are reset.

0000

T002

T001

T000

1000

0500 0501

0501

0500

0500

0000

1000

T002

1001

T000

T001

T002

1001

0501

1002

T000

1002

T001

1003

1001

1003

1002

1003

#00010T000

1000DIFU

1001STG

1001JMP

1003JMP

1002JMP

#00030T002

#00020T001

#00010T000

1000DIFU

1002STG

1003STG

#00020T001

1003

#00030T002

1001SET

By using an extended ladder diagram as shownabove, the program can be executed in thesequence of the processing to be performed. Soeven a person who uses a relay sequence for thefirst time can understand the processing contents.By combining the STG instruction, double coilscan also be used.

1.5.2 Advantages of Extended Ladder DiagramsThe number of lines in a ladder diagram can be reduced.Because both output instructions and input instructions can be written side by side,the number of program lines can be reduced.As the result, the contents of the program can be seen at a glance.

ExampleWhen DM0000 stores 1000, 0500 turns ON.

2000, 0501 turns ON.3000, 0502 turns ON.

Conventional ladder diagram Extended ladder diagram

Processing sequence is clear.Ladder symbols can be laid out in processing sequence, so the program flow iseasier to understand. In addition, maintainability is considerably improved.

ExampleWhen the start switch is set to ON, a lamp is lit for three seconds, a buzzer issounded for two seconds, and then the motor starts to rotate.

Conventional ladder diagram Extended ladder diagram

Page 55: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.5 Extended Ladder Diagrams

3-31

11

Chapter 1 Programming

0501

05000000

LD 0000OUT 0500OUT 0501

LD 0000OUT 0500CONOUT 0501

050105000000

The CON instruction for connection is added.(The scan time is not affected.)

At the rising edge of input0001, 1002 turns ON.

0001

1000

1002 0000

0002

1000

1001

1003 1000 1001

1001 0500

1003DIFU

1002DIFU

05000000 10000001

1000

10010002

1001

At the rising edge of input1003, 1002 turns ON.If input 0000 is ON, 1000turns ON.

If 1000 is ON, 1001 turns ON.

When 1001 turns ON, output 0500turns ON.

Input 0000turns ON.

Input 0001turns ON.

Input 0002turns ON.

Output 0500turns ON.

Note: When an extended ladder diagram is used, the number of lines in ladderdiagram may be reduced. However, this may not necessarily reduce the number ofmnemonics in the program.

Conventional ladder diagram Extended ladder diagram

1.5.3 Example of an Extended Ladder Diagram Using W-UE

Only when inputs are given in the order "0000 0001 0002", output 0500 turnsON.

Conventional ladder diagram Extended ladder diagram

Because the program can be written in only one line when an extended adderdiagram is used, it is easier to look at and understand compared with a programwritten using a conventional ladder diagram.

Page 56: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

1.5 Extended Ladder Diagrams

3-32

1

Chapter 1 Programming

Page 57: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

Chapter 2Instructions

Describes the concrete usage of instructions in the KV Series.Refer to "Chapter 3 Interrupts" on page 3-191 for details of interrupt instructions.Refer to "Chapter 4 High-speed counters" on page 3-203 for details of the high-speed counters used in the application instruction.

2.1 Instruction List [Visual KV Series] .......................................3-342.1.1 Basic Instructions ................................................................................. 3-342.1.2 Application Instructions ........................................................................ 3-362.1.3 Arithmetic Instructions .......................................................................... 3-382.1.4 Interrupt Instructions ............................................................................ 3-412.1.5 Function No. List (Alphabetical order) .................................................. 3-41

2.2 Instruction List [KV-300 Series, KV-10/80] ..........................3-422.2.1 Basic Instructions ................................................................................. 3-422.2.2 Application Instructions ........................................................................ 3-452.2.3 Arithmetic Instructions .......................................................................... 3-482.2.4 Interrupt Instructions ............................................................................ 3-54

2.3 Convention Details .................................................................3-55

2.4 Instruction Details ..................................................................3-562.4.1 Basic Instructions ................................................................................. 3-562.4.2 Application Instructions ........................................................................ 3-952.4.3 Arithmetic Instructions .......................................................................... 3-134

2.5 Programming Notes ...............................................................3-189

Page 58: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

2.1 Instruction List Visual KV Series

3-34

2

Chapter 2 Instructions

2.1 Instruction ListThe KV Series uses 80 instructions.The instructions are divided into four categories according to their functions: basicinstructions, application instructions, arithmetic instructions, and interrupt instruc-tions.The following is an overview of applications and functions. For details, refer to therespective description pages for each instruction.

2.1.1 Basic Instructions

Visual KV Series

LOAD LD

R No.T/C No.

LOAD BAR LDB

AND AND

AND BAR ANB

OR OR

OR BAR ORB

AND LOAD ANL

OR LOAD ORL

OUT OUT

R No.

OUT BAR OUB

SET SET

RESET RES

0.1-sTIMER TMR T No.,

# presetvalue0.01-s

TIMERTMH

(FUN49)

0000 to 17915T000 to T249C000 to C249CTC0 to CTC3

0500 to 19152009

2300 to 17915

0500 to 19152009

2300 to 17915T000 to T249C000 to C249

0500 to 19152009

2100 to 17915T000 to T249C000 to C249CTH0 to CTH1CTC0 to CTC3

000 to 249#00000 to#65535

0.7 to 1.6

0.7 to 1.6

0.7 to 0.9

0.7 to 0.9

0.7 to 0.9

0.7 to 0.9

0.8

0.8

1.5

1.5

1.9 to 12.8

1.9 to 20.5

12.0 to 17.8

12.0 to 17.8

3 (12)

3 (12)

3 (8)

3 (8)

3 (8)

3 (8)

1 (4)

1 (4)

3 (12)

3 (12)

3 (14)

3 (14)

2 (6)

2 (6)

Connects N.O. contact to bus.

Connects N.C. contact to bus.

Connects N.O. contact inseries with previous contact.

Connects N.C. contact inseries with previous contact.

Connects N.O. contact inparallel with previous contact.

Connects N.C. contact inparallel with previous contact.

Connects in series blocksmade of one or morecontacts.Connects in parallel blocksmade of one or morecontacts.

Outputs input ON/OFF statusto R coil.

Outputs inverted input ON/OFF status to R coil.

Forces relay ON and holdsthis status when input is ON.

Forces R/T/C OFF when inputis ON.

16-bit on-delay T that countsdown in 0.1-s decrements.

16-bit on-delay T that countsdown in 0.01-s decrements.

3-57

3-57

3-58

3-58

3-60

3-60

3-61

3-63

3-65

3-65

3-66

3-66

3-67

Instruction Symbol Mnemonic Operand Operand value Function Exec.time(µs) Bytes Page

R No.T/C No.

nnnn

nnnn

nnnn

nnnn

nnnn

nnnn

nnnn

nnnn

nnnnSET

nnnnRES

#ddddd

Txxx

#ddddd

TxxxTH

3-68

Page 59: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

Visual KV Series

3-35

12

Chapter 2 Instructions

2.1 Instruction List

• Number of bytes represents the memory capacity required for each instruction.• Number in ( ) represents the memory capacity required for object code of each

instruction.• *1 34 + 0.25 + n x 0.25 (n: No. of shift steps)• All operand values are shown in normal notation. The corresponding relay num-

bers in X-Y-M notation are shown below:

Normal notation X-Y-M notation0000 to 0415 X000 to X04F0500 to 0915 Y050 to Y09F1000 to 6915 M1000 to M69157000 to 17915 X700 to X174F or Y750 to Y179F

Instruction Symbol Mnemonic Operand Operand value Function Exec.time(µs) Bytes Page

1-msTIMER

TMS(FUN51)

COUNTER C# preset value,C No., counter

input R

UP-DOWNCOUNTER

UDC(FUN52)

C No.,# preset value

#00000 to#65535

000 to 2490000 to 17915

000 to 249#00000 to

#65535

12.0 to 17.8

12.0 to 17.8

13.0 to 24.0

2 (7)

4 (7)

2 (10)

16-bit on-delay T thatcounts down in 1-msdecrements.

Sets 16-bit up-counter.

Sets a 16-bit up-downcounter.

000 to 249#0000 to #65535

3-72

3-76

3-69

DIFFEREN-TIATE UP

DIFU(FUN10)

R No.DIFFEREN-

TIATEDOWN

DIFD(FUN09)

KEEP KEEP(FUN22)

R No.

SHIFT SFT(FUN39)

nnnn: 1st RNo. mmmm:Last R No.

HIGHSPEED

HSP(FUN18) R No.

MASTERCONTROL

MC(FUN24)

MASTERCONTROL

RESET

MCR(FUN25)

MEMORYSWITCH

MEMSW(FUN26) $ constant

NOPNOP

(FUN30)

END END

END HI ENDH

1000 to 19153000 to 9915

0500 to 19152009

2100 to 17915

1000 to 19153000 to 9915

(KV-10)0000 to 0005

(KV-16)0000 to 0009

(KV-24)0000 to 0015

(KV-40)0000 to 0107

$ 0000 to$ FFFF

11.2 to 13.2

10.0 to 12.8

8.2 to 19.8

(*)

3.8 to 9.4

0.2

0.2

––

––

––

––

3 (10)

3 (10)

3 (11)

5 (15)

3 (8)

1 (4)

1 (0)

3 (0)

1 (0)

1 (1)

1 (0)

Turns ON R for 1 scantime at rising edge ofinput.Turns ON R for 1 scantime at falling edge ofinput.Turns ON R and holds thisstatus when SET input is ON.Turns OFF R when RESETinput is ON.

Sets shift register.

Reduces input relay timeconstant to 10 µs forhigher input response.

Selects ON/OFF status ofR coils, Ts, or Cs.

Represents end of MC.

Sets memory switches.

Performs no operation.

Indicates end of eachroutine of program.

Indicates end of entireprogram.

3-78

3-78

3-80

3-82

3-86

3-89

3-89

T No.,# preset value

3-94

3-94

3-94

#dddddTxxxT

S

#ddddd

nnnnCxxx

UDC xxx#ddddd

UPDWRES

nnnnDIFU

nnnn

DIFD

KEEP

SETRES

nnnn

SFTnnnn

mmmm

DCLKRES

HSPnnnn

MC

MCR

MEMSW$xxxx

END

ENDH

3-92

Page 60: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

2.1 Instruction List Visual KV Series

3-36

2

Chapter 2 Instructions

• Number of bytes represents the memory capacity required for each instruction.• Number in ( ) represents the memory capacity required for object code of each

instruction.• All operand values are shown in normal notation. The corresponding relay

numbers in X-Y-M notation are shown below:

Normal notation X-Y-M notation0000 to 0415 X000 to X04F0500 to 0915 Y050 to Y09F1000 to 6915 M1000 to M69157000 to 17915 X700 to X174F or Y750 to Y179F

2.1.2 Application Instructions

Instruction Symbol Mnemonic Operand Operand value FunctionExec.time

(µs) Bytes Page

WAIT ON

WAIT OFF

WAIT UPEDGE

WAITDOWNEDGE

CONNECT

PUSH

READ

POP

W-ON

W-OFF

W-UE

W-DE

CON(FUN 06)

MPS

MRD

MPP

nnnn:R, T, CNos.

mmmm:R No.R No.

17915T000 to T249C000 to C249CTC0 to CTC3

mmmm:1000 to 19153000 to 99151000 to 1915

10.4 to 12.6

13.6 to 18.5

13.6 to 18.5

6.8 to 5.3

3.2

6.8

10.5 to 13.0

5 (12)

5 (12)

5 (12)

1 (0)

1 (4)

1 (4)

1 (4)

R (output operand [mmmm])when R, T, or C (input operand[nnnn]) is ON.

Turns ON R (output operand[mmmm]) at falling edge of R, T,or C (input operand [nnnn]).Represents series connectionof output instruction togetherwith another instruction.

Stores input status andarithmetic flag.

Reads input status andarithmetic flag stored withPUSH.

3-96

3-96

3-98

3-98

3-102

STEP

STEP END

STP(FUN 45)

STE(FUN 43)

R No.nnnn:

0000 to

0500 to 9915T000 to T249C000 to C249CTC0 to CTC3

11.2 to 13.4

2.5

5 (12)

3 (10)

1 (0)

Reads & clears input statusand arithmetic flag storedwith PUSH.

Is used with STEP to makeprogram step.

STAGE

JUMP

ENDSTAGE

STG(FUN 44)

JMP(FUN 21)

ENDS(FUN 14)

R, T, CNos.

3000 to 99150000 to 0009

4.5 to 12.5

4.3 to 7.5

3 (10)

3 (8)

1 (4)

Turns ON

Turns ON R (output operand[mmmm]) when R, T, or C (inputoperand [nnnn]) is OFF.Turns ON R (output operand[mmmm]) at rising edge of R, T,or C (input operand [nnnn]).

Executes instructions in STGblock when R (operand) is ON.

When input is ON, turns R ofcurrent stage OFF and movesto stage specified by operand.

Turns current stage OFF andnext stage ON when input isON.

Executes program betweenSTP & STE when R (oper-and) is ON.

3-103

3-103

3-106

3-106

3-106

3-114

3-114

nnnnON

mmmm

nnnnOFF

mmmm

nnnn

mmmm

nnnn

mmmm

nnnn

STG

nnnn

JMP

ENDS

STPnnnn

STE

3-103

Page 61: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

Visual KV Series

3-37

12

Chapter 2 Instructions

2.1 Instruction List

• Number of bytes represents the memory capacity required for each instruction.• Number in ( ) represents the memory capacity required for object code of each

instruction.• All operand values are shown in normal notation. The corresponding relay

numbers in X-Y-M notation are shown below:

Normal notation X-Y-M notation0000 to 0415 X000 to X04F0500 to 0915 Y050 to Y09F1000 to 6915 M1000 to M69157000 to 17915 X700 to X174F or Y750 to Y179F

Instruction Symbol Mnemonic Operand Operand value Function Exec.time(µs) Bytes Page

INTERVALTIMER

16-BITCOUNTER

16-BITCOUNTERCOMPARA-

TOR

16-BITCOUNTER

16-BITCOUNTERCOMPARA-

TOR

SUBROUTINECALL

ITVL

CTH

CTC

CALL(FUN 03)

SBN(FUN 38)

RET(FUN 33)

DMnnnn:DM No.mmmm: RNo.

Count inputR

n:Comparator

No.ddddd:# preset

value

n:Comparator

No.ddddd:

# presetvalue

SubroutineNo.

DMnnnn:DM0000 toDM1985mmmm:

1000 to 19123000 to 9912

0004210021012102

n: 0,1ddddd: #00001

to #65535

00050500220022012202

20.0 to 80.0

14.4

2.3 to 3.5

5.4 to 6.5

4.3

5 (10)

4 (6)

2 (6)

4 (6)

2 (6)

2 (8)

Measures pulse-to-pulseinterval & pulse width inspecified mode.

16-bit (0 to 65535) up-down counter for clockpulses with input responsefrequency of 30 kHz.

Hardware-based comparatorbetween preset & currentvalues of high-speed counter(CTH0). This comparator isturned ON when thesevalues are equal.

Executes subroutinespecified by operand.

Represents beginning ofsubroutine specified byoperand.

Represents end ofsubroutine.

3-117

3-204

3-204

3-204

REPEATSTART

REPEAT END

16-KEY INPUT

FOR(FUN 16)

NEXT(FUN 29)

HKEY(FUN 17)

# constant,DM No.TMxx

nnnn:Input Rmmmm:Output R

#00000 to#65535

DM0000 toDM1999

TM00 to TM29

nnnn:0000 to 415

mmmm:0500 to 915

12.0 to18.0

0.5

22.1 to180.0

3 (20)

1 (4)

5 (10)

Executes programbetween FOR & NEXTfor number of timesspecified by operand.

Represents end ofrepetition.

Reads 16-key data bytime-sharing and outputsthese data into specialutility Rs 2900 to 2915.

3-125

3-125

SUBROUTINEENTRY

SUBROUTINERETURN

CTH

CTC

Count inputR

SubroutineNo.

n: 2,3ddddd: #00001

to #65535

00 to 99

00 to 99

14.4

2.3 to 3.5

2 (4)

1 (4)

16-bit (0 to 65535) up-down counter for clockpulses with inputresponse frequency of 30kHz.

Hardware-based comparatorbetween preset & currentvalues of high-speed counter(CTH1). This comparator isturned ON when thesevalues are equal.

3-204

3-122

3-122

3-131

ITVLPLSDMnnnnPAUSEmmmmRES

CTH0nnnn

CTCn#ddddd

CTH1nnnn

CTCn#ddddd

CALLnn

SBNnn

RET

FORnnnn

HKEYnnnn

mmmm

NEXT

3-122

Page 62: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

2.1 Instruction List Visual KV Series

3-38

2

Chapter 2 Instructions

• Number of bytes represents the memory capacity required for each instruction.• Number in ( ) represents the memory capacity required for object code of each

instruction.

2.1.3 Arithmetic Instructions

Instruction Symbol Mnemonic Operand Operand value Function Exec.time(µs) Bytes Page

DATAMEMORY

WRITE

TRIMMERSETTING

LOAD A

STORE A

COMPARE

ADD

SUBTRACT

MULTIPLY

DW

TMIN(FUN 50)

@TMIN@(FUN 50)

LDA(FUN 23)

@LDA@(FUN 23)

STA(FUN 42)

@STA@(FUN 42)

CMP(FUN 04)

@CMP@(FUN 04)

ADD(FUN00)

@ADD@(FUN 00)

SUB(FUN 46)

@SUB@(FUN 46)

MUL(FUN 28)

@MUL@(FUN28)

nnnn:#/$ constantDMmmmm:

DM No.

Trimmer No.

R No.,C/T No.,DM No,TM xx,

#/$ constant,#TMxx

R No.,C/T No.,DM No.,TM xx,#TMxx

DM/TM No.TMxx,

#/$ constant,#TMxx

nnnn:#0000 to#65535

$0000 to$FFFF

DMmmmm:DM0000 toDM1999

0 to 1

0000 to 17915T000 to T249C000 to C249CTH0 to CTH1

DM0000 toDM1999

TM00 to TM31#00000 to

#65535$0000 to $FFFF

#TM00 to#TM29

0500 to 19152100 to 17915T000 to T249C000 to C249

CTH0 toCTC3

DM0000 toDM1999

TM00 to TM29#TM00 to#TM29

DM0000 toDM1999

TM00 to TM31#00000 to

#65535$0000 to$FFFF

#TM00 to#TM29

8.0

8.9

20.9

6.4 to 14.0

18.4 to 26.0

6.6 to 28.5

18.0 to 40.5

10.8 to 35.6

22.8 to 47.6

9.4 to 34.2

21.4 to 46.2

10.8 to 35.6

22.8 to 47.6

14.4 to 38.1

26.4 to 50.1

5 (8)

1 (6)

1 (16)

3 (8)

3 (18)

3 (8)

3 (18)

3 (6)

3 (16)

3 (6)

3 (16)

3 (6)

3 (16)

3 (6)

3 (16)

Writes constant into datamemory.

Inputs value set byaccess window’s digitaltrimmer (0 to 65535) tointernal register.

Inputs value specified byoperand into internalregister or inputs currentvalue when T/C isspecified as operand.

Transfers content ofinternal register tolocation specified byoperand, or changespreset value when T/C isspecified as operand.

Compares content ofinternal register andvalue specified byoperand.

Adds content of internalregister and valuespecified by operand andinputs result back tosame register.

Subtracts value specifiedby operand from contentof register and inputsresult back to sameregister.

Multiplies content ofinternal register by valuespecified by operand andinputs result back tosame register.

3-136

3-138

3-140

3-140

3-150

3-150

nnnn

DMmmmmDW

n TMIN

n TMIN

nnnnLDA

nnnnLDA

nnnnSTA

nnnnSTA

nnnnCMP

nnnnCMP

nnnnADD

nnnnADD

nnnnSUB

nnnnSUB

nnnnMUL

nnnnMUL

3-150

3-146

Page 63: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

Visual KV Series

3-39

12

Chapter 2 Instructions

2.1 Instruction List

• Number of bytes represents the memory capacity required for each instruction.• Number in ( ) represents the memory capacity required for object code of each

instruction.• All operand values are shown in normal notation. The corresponding relay num-

bers in X-Y-M notation are shown below:

Normal notation X-Y-M notation0000 to 0415 X000 to X04F0500 to 0915 Y050 to Y09F1000 to 6915 M1000 to M69157000 to 17915 X700 to X174F or Y750 to Y179F

@DIV@(FUN 11)

Instruction Symbol Mnemonic Operand Operand value Function Exec.time(µs) Bytes Page

DIVIDE

DIV(FUN 11)

17.4 to 43.3

29.4 to 55.3

3 (6)

3 (16)

Divides content of internalregister by value specifiedby operand and inputsresult back to sameregister.

R No.,DM No.,TM xx,

#/$ constant,#TMxx

DM0000 toDM1999

TM00 to TM31#00000 to

#65535$0000 to$FFFF

#TM00 to#TM29

AND A

OR A

EXCLUSIVEOR A

SHIFTRIGHT A

SHIFT LEFTA

ROTATERIGHT A

ROTATELEFT A

ANDA(FUN 01)

@ANDA@(FUN 01)

ORA(FNC 31)

@ORA@(FUN 31)

EORA(FUN 15)

@EORA@(FUN 15)

SRA(FNC 41)

@SRA@(FUN 41)

SLA(FNC 40)

@SLA@(FUN 40)

RRA(FUN 37)

@RRA@(FUN 37)

RLA(FUN 35)

@RLA@(FUN 35)

R No.,DM No.,TM xx,

#/$ constant,#TMxx

R No.,DM No.,TM xx,

#/$ constant,#TMxx

# constant

0000 to 17915DM0000 to

DM1999TM00 to TM31

#00000 to#65535

$0000 to$FFFF

#TM00 to#TM29

0000 to 17915DM0000 toDM1999

TM00 to TM31#00000 to#65535

$0000 to$FFFF

#TM00 to#TM29

8.2 to 33.1

20.2 to 45.1

8.2 to 33.1

20.2 to 45.1

8.2 to 33.1

20.2 to 45.1

9.3 to 27.6

21.3 to 39.6

9.2 to 27.6

21.2 to 39.6

10.3 to 28.6

22.3 to 40.6

10.3 to 28.6

22.3 to 40.6

3 (8)

3 (18)

3 (8)

3 (18)

3 (8)

3 (18)

2 (6)

2 (16)

2 (6)

2 (16)

2 (6)

2 (16)

2 (6)

2 (16)

ANDs each of 16 bits ofinternal register and thatof value specified byoperand, and inputs resultback to same register.

ORs each of 16 bits ofinternal register and thatof value specified byoperand, and inputs resultback to same register.

EXCLUSIVE-ORs each of16 bits of internal registerand that of value specifiedby operand, and inputsresult back to sameregister.

Moves content of internalregister serially left byvalue specified byoperand.

Rotates contents ofinternal register and carrybit (2009) clockwise byoperand value.

Rotates contents ofinternal register and carrybit (2009) counterclock-wise by operand value.

Moves content of internalregister serially right byvalue specified byoperand.

3-159

3-161

3-164

3-166

#01 to #16

3-166

3-169

nnnnDIV

nnnnDIV

nnnnANDA

nnnnANDA

nnnnORA

nnnnORA

nnnnEORA

nnnnEORA

#ddSRA

#ddSRA

#ddSLA

#ddSLA

#ddRRA

#ddRRA

#ddRLA

#ddRLA

3-169

3-150

Page 64: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

2.1 Instruction List Visual KV Series

3-40

2

Chapter 2 Instructions

• Number of bytes represents the memory capacity required for each instruction.• Number in ( ) represents the memory capacity required for object code of each

instruction.• All operand values are shown in normal notation. The corresponding relay

numbers in X-Y-M notation are shown below:

Normal notation X-Y-M notation0000 to 0415 X000 to X04F0500 to 0915 Y050 to Y09F1000 to 6915 M1000 to M69157000 to 17915 X700 to X174F or Y750 to Y179F (OUTPUT)

Converts content ofinternal register (4-digitBCD) into 16-bit binarydata.

Converts content ofinternal register (16-bitbinary) into 4-digit BCDdata.

DEMULTI-PLEXER

TRANSFERBCD

TRANSFERBIN

ASCIICONVERT

REVERSEASCII

CONVERT

SQUAREROOT

DMX(FUN 12)

@DMX@(FUN 12)

TBCD(FUN 47)

@TBCD@(FUN 47)

TBIN(FUN 48)

@TBIN@(FUN 48)

ASC(FUN 02)

@ASC@(FUN 02)

RASC(FUN 32)

@RASC@(FUN 32)

ROOT(FUN 36)

@ROOT@(FUN 36)

22.6

34.6

5.6

17.6

9.6

21.6

9.7

21.7

9.3

21.3

95.7 1 (4)

1 (4)

1 (14)

1 (4)

1 (14)

1 (14)

1 (4)

1 (14)

1 (4)

1 (14)

1 (4)

1 (14)

Converts position ofhighest order bit with 1 ininternal register into 4-bitdata.

Converts content of lowerorder 8 bytes of internalregister into 2-digit ASCIIcode.

Converts 2-digit ASCIIcode of internal registerinto 2-digit numericalvalue.

Takes square root of 32-bit data (TM00: higherorder byte, internalregister: lower order byte)and inputs result back tosame register.

3-176

3-180

3-180

3-183

3-183

Instruction Symbol Mnemonic Operand Operandvalue

Function Exec.time(µs) Bytes Page

COMPLE-MENT

INCREMENTMEMORY

DECRE-MENT

MEMORY

MULTI-PLEXER

COM(FUN 05)

@COM@(FUN 05)

INC(FNC 19)

@INC@(FUN 19)

DEC(FNC 07)

@DEC@(FUN 07)

MPX(FUN 27)

@MPX@(FUN 27)

DM/TM No.

DM/TM No.

DM0000 toDM1999TM00 to

TM29

5.6

17.6

9.8

21.8

10.4

22.4

10.1

22.1

1 (4)

1 (14)

3 (6)

3 (16)

3 (6)

3 (16)

1 (6)

1 (16)

Inverts content of each bitin internal register.

Adds 1 to content of datamemory specified byoperand.

Subtracts 1 from contentof data memory specifiedby operand.

Converts 4-bit data(specified by operand) ofinternal register into 16-bitdata.

3-171

3-172

3-172

# constant

DM0000 toDM1999TM00 toTM29

#0 to #3

COM

COM

nnnnINC

nnnnINC

nnnnDEC

nnnnDEC

#nMPX

#nMPX

DMX

DMX

TBCD

TBCD

TBIN

TBIN

ASC

ASC

RASC

RASC

ROOT

ROOT

3-185

3-176

107.7

Page 65: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

Visual KV Series

3-41

12

Chapter 2 Instructions

2.1 Instruction List

• Number of bytes represents the memory capacity required for each instruction.• Number in ( ) represents the memory capacity required for object code of each

instruction.• All operand values are shown in normal notation. The corresponding relay

numbers in X-Y-M notation are shown below:

Normal notation X-Y-M notation0000 to 0415 X000 to X04F0500 to 0915 Y050 to Y09F1000 to 6915 M1000 to M69157000 to 17915 X700 to X174F or Y750 to Y179F

2.1.5 Function No. List (Alphabetical order)The following list shows the function Nos. used to enter instructions with the KV-P3E(01) handheld programmer. Refer to "Chapter 6 Handheld Programmer" on page 1-195 for details.

Reference: To find function No. assigned to desired function:1. Press the [FUN] key.2. When the cursor appears at the position where the function No. is to be entered,

press the ON or OFF key and scroll the functions and assigned Nos. to find thedesired function.

2.1.4 Interrupt Instructions

Instruction Symbol Mnemonic Operand Operand value Function Exec.time(µs) Bytes Page

INTERRUPTDISABLED

INTERRUPTENABLED

INTERRUPT

RETURNINTERRUPT

DI(FUN 08)

EI(FUN 13)

INT(FUN 20)

RETI(FUN 34)

R No.

ComparatorNo.

000 to 003

CTC0 toCTC3

2.2

4.0

60.0 to90.0

60.0 to90.0

18.0 to22.0

1 (12)

1 (10)

1 (8)

1 (4)

Disables execution ofinterrupt.

Enables execution ofinterrupt.

Executes interruptinstructions between INTand RETI at rising/fallingedge of input relays 0000through 0003.

Used with comparatorsCTC0 to CTC3 andexecutes instructionsbetween INT and RETI.

Represents end ofinterrupt.

3-193

3-193

3-192

3-1921 (8)

3-192

DI

EI

INTnnnn

INTCTCn

RETI

.oNnoitcnuF noitcurtsnI

00 DDA

10 ADNA

20 CSA

30 LLAC

40 PMC

50 MOC

60 NOC

70 CED

80 ID

90 DFID

01 UFID

11 VID

21 XMD

.oNnoitcnuF noitcurtsnI

62 WSMEM

72 XPM

82 LUM

92 TXEN

03 PON

13 ARO

23 CSAR

33 TER

43 1TER

53 ALR

63 TOOR

73 ARR

83 NBS

.oNnoitcnuF noitcurtsnI

31 IE

41 SDNE

51 AROE

61 ROF

71 YEKH

81 PSH

91 CNI

02 TNI

12 PMJ

22 PEEK

32 ADL

42 CM

52 RCM

.oNnoitcnuF noitcurtsnI

93 TFS

04 ALS

14 ARS

24 ATS

34 ETS

44 GTS

54 PTS

64 BUS

74 DCBT

84 NIBT

94 HMT

05 NIMT

15 SMT

25 CDU

Page 66: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

KV-300 Series, KV-10/802.2 Instruction List KV-300 Series,

3-42

2

Chapter 2 Instructions

2.2 Instruction List• Number of bytes represents the memory capacity required for each instruction.• Number in ( ) represents the memory capacity required for object code of each

instruction.• Abbreviations: R: Relay, T: Timer, C: Counter, #: Decimal, $: Hex.

2.2.1 Basic InstructionsKV-10/16/24/40/80

KV-300 Series, KV-10/80

nnnnLOAD

nnnn

nnnn

nnnn

nnnn

nnnn

nnnn

nnnn

(SET)nnnn

LD

R No.T/C No.

LOAD BAR LDB

AND AND

AND BAR ANB

OR OR

OR BAR ORB

AND LOAD ANL

OR LOAD ORL

OUT OUT

R No.

OUT BAR OUB

SET SET

RESET RES

0.1-s TIMER TMR

T No.,# preset

value

0.01-sTIMER

TMH(FNC49)

1-ms TIMERTMS

(FNC51)

COUNTER C

# presetvalue, C

No., clocksource R

UP-DOWNCOUNTER

UDC(FNC52)

C No.,# preset

value

0000 to 2915T000 to T063C000 to C063CTC0 to CTC3

0500 to 19152009

2300 to 2915

0500 to 19152009

2100 to 2915T000 to T063C000 to C063

0500 to 19152009

2100 to 2915T000 to T063C000 to C063CTH0 to CTH1CTC0 to CTC3

(RES)nnnn

#ddddd

T xxx

#dddddxxxH

#dddddxxxS

nnnn

#dddddC xxx

UDCxxx#dddddUP

DWRES

000 to 063#00000 to#65535

#00000 to65535

000 to 0630000 to 6915

000 to 063#00000 to#65535

0000 to 6915T000 to T119C000 to C119CTC0 to CTC3

0500 to 19152009

2300 to 6915

0500 to 19152009

2100 to 6915T000 to T119C000 to C119

0500 to 19152009

2100 to 6915T000 to T119C000 to C119CTH0 to CTH1CTC0 to CTC3

000 to 119#00000 to#65535

#00000 to#65535

000 to 1190000 to 6915

000 to 119#00000 to#65535

1.5 to 2.5

2.1 to 3.5

1.5 to 2.5

2.7 to 4.5

1.5 to 2.5

2.7 to 4.5

1.0 to 1.4

1.0 to 1.4

5.2 to 8.4

6.4 to 10.4

3.1 to 23.0

3.1 to 24.0

17.0 to 22.0

17.0 to 22.0

17.0 to 22.0

19.0 to 21.0

21.0 to 26.0

3 (4)

3 (6)

3 (4)

3 (8)

3 (4)

3 (8)

1 (2)

1 (2)

3 (13)

3 (17)

3 (8)

3 (8)

2 (5)

2 (5)

2 (5)

4 (7)

2 (5)

Connects N.O. contactto bus.

Connects N.C. contactto bus.

Connects N.O. contactin series with previouscontact.Connects N.C. contactin series with previouscontact.Connects N.O. contactin parallel with previouscontact.Connects N.C. contactin parallel with previouscontact.Connects in seriesblocks made of one ormore contacts.Connects in parallelblocks made of one ormore contacts.Outputs input ON/OFFstatus to R coil.Outputs inverted input

ON/OFF status to Rcoil.

Forces R ON and holdsthis status when input isON.

Forces R/T/C OFFwhen input is ON.

16-bit on-delay T thatcounts down in 0.1-sdecrements.16-bit on-delay T thatcounts down in 0.01-sdecrements.16-bit on-delay T thatcounts down in 1-msdecrements.

Sets 16-bit up-counter.

Sets a 16-bit up-downcounter.

Page

3-57

3-57

3-58

3-58

3-60

3-60

3-61

3-63

3-65

3-65

3-66

3-66

3-67

3-68

3-69

3-72

KV-10/16/24/40/80

Instruction Symbol Mnemonic Operand Operand valueKV-10/16

Operand valueKV-24/40/80

Exec.time(µs)

BytesFunction

3-76

Page 67: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

KV-300 Series, KV-10/80

3-43

12

Chapter 2 Instructions

2.2 Instruction List

KV-300

Instruction Symbol Mnemonic Operand Operand value Exec.time(µs)

BytesFunction Page

LOADnnnn

nnnn

nnnn

nnnn

nnnn

nnnn

LOAD BAR

AND

AND BAR

OR

OR BAR

AND LOAD

OR LOAD

LD

LDB

AND

ANB

OR

ORB

ANL

ORL

R No.T/C No.

0000 to 00090500 to 17915T000 to T249C000 to C249CTC0 to CTC3

0.15 to 0.70

0.15 to 0.90

0.15 to 0.50

0.15 to 0.80

0.15 to 0.50

0.15 to 0.80

0.55

0.55

3 (5)

3 (7)

3 (4)

3 (8)

3 (4)

3 (8)

1 (3)

1 (3)

Connects N.O. contactto bus.

Connects N.C. contactto bus.

Connects N.O. contactin series with previouscontact.Connects N.C. contactin series with previouscontact.Connects N.O. contactin parallel withprevious contact.Connects N.C. contactin parallel withprevious contact.Connects in seriesblocks made of one ormore contacts.Connects in parallelblocks made of one ormore contacts.

3-57

3-57

3-58

3-58

3-60

3-60

3-61

3-63

KV-300

nnnnDIFU

nnnnDIFD

KEEPSETRES

nnnn

SFTDCLKRES

nnnn

mmmm

MC

HSPnnnn

MCR

$xxxxMEMSW

$xxxx

END

ENDH

DIFFEREN-TIATE UP

DIFU(FNC10)

R No.DIFFEREN-

TIATEDOWN

DIFD(FNC09)

KEEPKEEP

(FNC22)R No.

SHIFT SFT(FNC39)

R No.1st& last R

Nos.

HIGHSPEED

HSP(FNC18) R No.

MASTERCONTROL

MC(FNC24)

MASTERCONTROL

RESET

MCR(FNC25)

MEMORYSWITCH

MEMSW(FNC26)

$ constant

NOP NOP(FNC30)

END END

END HI ENDH

1000 to 1915

0500 to 19152009

2100 to 2915

1000 to 1915

(KV-10)0000 to 0005

(KV-16)0000 to 0009

$ 0000 to $ FFFF

1000 to 19153000 to 6915

0500 to 19152009

2100 to 69151000 to

19153000 to6915

(KV-24)0000 to 0015

(KV-40)0000 to 0107

11.0 to 13.0

11.0 to 13.0

9.0 to 26.0

(*)

8.0 to 9.0

1.8 to 3.2

0.6 to 1.0

––

––

––

––

3 (5)

3 (5)

3 (5)

5 (7)

3 (4)

1 (7)

1 (2)

3 (0)

1 (0)

1 (3)

1 (0)

Turns ON R for 1scan time at risingedge of input.

Turns ON R for 1scan time at fallingedge of input.Turns ON R andholds this status whenSET input is ON.

Turns OFF R whenRESET input is ON.

Sets shift register.

Reduces input relay timeconstant to 25 ms forhigher input response.Selects ON/OFFstatus of R coils, Ts,or Cs.

Represents end of MC.Sets memory switches.

Performs no opera-tion.

Indicates end of eachroutine of program.

Indicates end of entireprogram.

3-78

3-78

3-80

3-82

3-86

3-89

3-89

3-92

3-94

3-94

KV-10/16/24/40/80

Instruction Symbol Mnemonic Operand Operand valueKV-10/16

Operand valueKV-24/40/80

Exec.time(µs)

BytesFunction Page

3-94

Page 68: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

KV-300 Series, KV-10/802.2 Instruction List KV-300 Series,

3-44

2

Chapter 2 Instructions

KV-300

Instruction Symbol Mnemonic Operand Operand value Exec.time(µs) Bytes

Function Page

OUT

OUT BAR

nnnn

nnnn

(SET)nnnn

(RES)nnnn

#ddddd

T xxx

#dddddxxxH

#dddddxxxS

nnnn

#dddddC xxx

UDCxxx#dddddUP

DWRES

nnnnDIFU

nnnnDIFD

KEEPSETRES

nnnn

SFTDCLKRES

nnnn

mmmm

HSPnnnn

MC

MCR

$xxxxMEMSW

$xxxx

END

ENDH

SET

RESET

0.1-s TIMER

0.01-s TIMER

1-ms TIMER

COUNTER

UP-DOWNCOUNTER

DIFFEREN-TIATE UP

DIFFEREN-TIATE DOWN

KEEP

SHIFT

HIGHSPEED

MASTERCONTROL

MASTERCONTROLRESET

MEMORYSWITCH

NOP

END

OUT

OUB

SET

RES

TMR

TMH(FNC49)

TMS(FNC51)

C

UDC(FNC52)

DIFUFNC10)

DIFD(FNC09)

KEEP(FNC22)

SFT(FNC39)

HSP(FNC18)

MC(FNC24)

MCR(FNC25)

MEMSW(FNC26)

NOP(FNC30)

END HI

END

ENDH

R No.

T No.,# presetvalue

# presetvalue, CNo., clocksource R

C No.,# presetvalue

R No.

R No.

1st &last RNos.

R No.

$ constant

0500 to 19152009

2300 to 17915

0500 to 19152009

2100 to 17915T000 to T249C000 to C249

0500 to 19152009

2100 to 17915T000 to T249C000 to C249CTH0 to CTH1CTC0 to CTC3

000 to 249#00000 to 65535

#00000 to #65535000 to 249

0000 to 00090500 to 17915

000 to 249#00000 to #65535

1000 to 19153000 to 6915

(*) 7000 to 9915

0500 to 19152009

2100 to 179151000 to 19153000 to 6915

(*) 7000 to 9915

0000 to 0009

$0000 to $FFFF

0.20 to 0.56

0.50 to 1.20

0.20 to 5.70

0.50 to 4.40

5.60 to 10.40

5.60 to 10.40

5.60 to 10.40

7.60 to 9.45

8.00 to 11.60

6.70

6.70

6.10 to 7.90

6.40 to 8.20

4.66 to 4.92

0.20

0.95

3 (8)

3 (11)

3 (12)

3 (12)

2 (7)

2 (7)

2 (7)

4 (7)

2 (10)

3 (10)

3 (10)

3 (11)

5 (15)

3 (8)

1 (4)

1 (0)

3 (0)

1 (0)

1 (1)

1 (0)

Outputs input ON/OFFstatus to R coil.

Outputs inverted inputON/OFF status to Rcoil.

Forces R ON and holdsthis status when inputis ON.

Forces R/T/C OFFwhen input is ON.

16-bit on-delay T thatcounts down in 0.1-sdecrements.16-bit on-delay T thatcounts down in 0.01-sdecrements.16-bit on-delay T thatcounts down in 1-msdecrements.

Sets 16-bit up-counter.

Sets a 16-bit up-downcounter.

Turns ON R for 1 scantime at rising edge ofinput.Turns ON R for 1 scantime at falling edge ofinput.Turns ON R and holdsthis status when SETinput is ON.

Turns OFF R whenRESET input is ON.

Sets shift register.

Reduces input relay timeconstant to 25 ms forhigher input response.

Selects ON/OFF statusof R coils, Ts, or Cs.

Represents end of MC.Sets memory switches.

Performs no operation.

Indicates end of eachroutine of program.

Indicates end of entireprogram.

3-65

3-65

3-66

3-66

3-67

3-68

3-69

3-72

3-76

3-78

3-78

3-80

3-82

3-86

3-89

3-89

3-92

3-94

3-94

Note: 14.0 + 3.0 x (n) to 17.0 + 3.0 x (n) (n represents number of times the originaldata is generated.)

3-94

Page 69: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

KV-300 Series, KV-10/80

3-45

12

Chapter 2 Instructions

2.2 Instruction List

2.2.2 Application InstructionsKV-10/16/24/40/80

KV-10/16/24/40/80

Instruction Symbol Mnemonic Operand Operand valueKV-10/16

Operand valueKV-24/40/80

Exec.time(µs) Bytes

Function Page

WAIT ON

WAIT OFF

WAIT UPEDGE

WAIT DOWNEDGE

CONNECT

PUSH

READ

POP

STAGE

JUMP

ENDSTAGE

STEP

STEP END

INTERVALTIMER

8-BITCOUNTER

8-BITCOUNTERCOMPARA-

TOR

16-BITCOUNTER

16-BITCOUNTERCOMPARA-

TOR

SUBROU-TINE CALL

SUBROU-TINE ENTRY

SUBROU-TINE

RETURN

W-ONnnnnON

mmmm

W-OFFnnnnOFF

mmmm

W-UE

W-D

CON[FNC 06]

MPS

MRD

MPP

STG[FNC 44]

JMP[FNC 21]

ENDS[FNC 14]

STP[FNC 45]

STE[FNC 43]

ITVL

CTH

CTC

CTH

CTC

CALL[FNC 03]

SBN[FNC 38]

RET[FNC 33]

nnnn:R,T, or C

No.

R No.

R, T, CNos.

DM & RNo.

Clocksource Rs

n:Comparator

No.ddddd: #

preset value

Clocksource Rs

n: Compara-tor No.

ddddd: #preset value

Subrou-tine No.

Subrou-tine No.

nnnn↑

mmmm

nnnn↓

mmmm

nnnnSTG

nnnnJMP

ENDS

STPnnnn

STE

ITVLPLS

PAUSERES

nnnnmmmm

DM

nnnnCTH0

#ddddd

CTCn

nnnnCTH1

#ddddd

CTCn

nn

CALL

nnSBN

RET

nnnn:0000 to 2915T000 to T063C000 to C063CTC0 to CTC3

mmmm:1000 to 1915

1000 to 1915

0000 to 2915T000 to T063C000 to C063CTC0 to CTC3

DM0000 toDM0985

1000 to 1912

00042100 to 2102

n: 0,1ddddd: #00000 to #00255

00052200 to 2202

n: 2,3ddddd: #00000 to #65535

00 to 99

00 to 99

nnnn:0000 to 6915T000 to T119C000 to C119CTC0 to CTC3

mmmm:1000 to 19153000 to 6915

1000 to 19153000 to 6915

0000 to 6915T000 to T119C000 to C119CTC0 to CTC3

DM0000 toDM1985

1000 to 19123000 to 6912

11.0 to13.0

11.0 to13.0

14.0 to18.0

14.0 to18.0

0.4 to0.6

11.0 to14.0

8.0 to10.0

10.0 to12.0

11.0 to14.0

10.0 to13.0

7.0 to9.0

3.7 to5.3

0.00

29.0 to79.0

9.0 to39.0

3.0 to 4.0

8.0 to48.0

3.0 to 4.0

8.0 to10.0

0.00

4.6 to 6.2

5 (7)

5 (7)

5 (7)

5 (7)

301

1 (3)

1 (3)

1 (3)

3 (7)

3 (5)

1 (3)

3 (7)

1 (0)

5 (7)

4 (4)

2 (5)

4 (4)

2 (5)

2 (6)

2 (0)

1 (5)

Turns ON R (2nd operand[mmmm]) when R, T, or C (1stoperand [nnnn]) turns ON.

When R, T, or C (1st operand[nnnn]) turns OFF, R (2ndoperand [mmmm]) turns ON.R (2nd operand [mmmm])turns ON at rising edge of R, T,or C (1st operand [nnnn]).

R (2nd operand [mmmm])turns ON at falling edge of R,T, or C (1st operand [nnnn]).

Represents series connectionof output instruction togetherwith another instruction.

Stores input status andarithmetic flag.

Reads input status andarithmetic flag stored withPUSH.Reads & clears input statusand arithmetic flag stored withPUSH.Executes instructions betweenSTG & JMP when R(operand) is ON.

Turns current stage OFF andnext stage ON when input isON.

Turns current stage OFF wheninput is ON.

Executes program betweenSTP & STE when R (operand)is ON.

Is used with STEP to makeprogram step.

Measures pulse-to-pulseinterval & pulse width inspecified mode.

8-bit (0 to255) up-counter forclock pulses with inputresponse frequency of 10 kHz.Hardware-based comparatorbetween preset & currentvalues of high speed counter.This comparator is turned ONwhen these values are equal.16-bit (0 to 65535) up-counterfor clock pulses with inputresponse frequency of 10 kHz.Hardware-based comparatorbetween preset & currentvalues of high speed counter.This comparator is turned ONwhen these values are equal.

Executes subroutine specifiedby operand.

Represents beginning ofsubroutine specified byoperand.

Represents end of subroutine.

3-96

3-96

3-98

3-98

3-102

3-103

3-103

3-103

3-106

3-106

3-106

3-114

3-114

3-117

3-277

3-277

3-204

3-204

3-122

3-122

3-122

Page 70: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

KV-300 Series, KV-10/802.2 Instruction List KV-300 Series,

3-46

2

Chapter 2 Instructions

KV-300KV-300

Instruction Symbol Mnemonic Operand Operand value Exec.time(µs) Bytes

Function Page

WAIT ONnnnnON

mmmm

nnnnOFF

mmmm

nnnn↑

mmmm

nnnn↓

mmmm

nnnnSTG

nnnnJMP

ENDS

STPnnnn

STE

ITVLPLS

PAUSERES

nnnnmmmm

DM

nnnnCTH0

WAIT OFF

WAIT UPEDGE

WAIT DOWNEDGE

CONNECT

PUSH

READ

POP

STAGE

JUMP

ENDSTAGE

STEP

STEP END

INTERVALTIMER

16-BITCOUNTER

W-ON

W-OFF

W-UE

W-DE

CON[FNC 06]

MPS

MRD

MPP

STG[FNC 44]

JMP[FNC 21]

ENDS[FNC 14]

STP[FNC 45]

STE[FNC 43]

ITVL

CTH

nnnn:R,T, orC No.

R No.

R, T,C Nos.

DM & R No.

Clocksource Rs

nnnn:0000 to 0009

0500 to 17915T000 to T249C000 to C249CTC0 to CTC3

mmmm:1000 to 19153000 to 6915

(*)7000 to 9915

1000 to 19153000 to 6915

(*)7000 to 9915

0000 to 00090500 to 6915

(*)7000 to 9915T000 to T249C000 to C249CTC0 to CTC3

DMnnnn:DM0000 to DM9985

mmmm:1000 to 19123000 to 6912

(*)7000 to 9912

0004210021012102

5.00 to 6.10

5.00 to 6.10

6.10 to 7.50

6.10 to 7.50

1.30

2.70

1.40

5.60 to 6.50

3.80 to 6.00

1.30

13.80 to17.30

3.85

5 (9)

5 (9)

5 (10)

5 (10)

1 (0)

1 (9)

1 (18)

1 (9)

3 (10)

3 (7)

1 (0)

3 (9)

1 (0)

5 (11)

4 (7)

Turns ON R (2nd operand[mmmm]) when R, T, or C (1stoperand [nnnn]) turns ON.

When R, T, or C (1st operand[nnnn]) turns OFF, R (2ndoperand [mmmm]) turns ON.R (2nd operand [mmmm])turns ON at rising edge of R,T, or C (1st operand [nnnn]).R (2nd operand [mmmm])turns ON at falling edge of R,T, or C (1st operand [nnnn]).

Represents series connectionof output instruction togetherwith another instruction.

Stores input status andarithmetic flag.

Reads input status andarithmetic flag stored withPUSH.

Reads & clears input statusand arithmetic flag storedwith PUSH.Executes instructionsbetween STG & JMP when R(operand) is ON.

Turns current stage OFF andnext stage ON when input isON.

Turns current stage OFFwhen input is ON.

Executes program betweenSTP & STE when R(operand) is ON.

Is used with STEP to makeprogram step.

Measures pulse-to-pulseinterval & pulse width inspecified mode.

16-bit (0 to 65535) up-counterfor clock pulses with inputresponse frequency of 30kHz.

3-96

3-96

3-98

3-98

3-102

3-103

3-103

3-103

3-106

3-106

3-106

3-114

3-114

3-117

3-204

KV-10/16/24/40/80

Instruction Symbol Mnemonic Operand Operand valueKV-10/16

Operand valueKV-24/40/80

Exec.time(µs)

BytesFunction Page

REPEATSTART

REPEATEND

16-KEYINPUT

FOR[FNC 16]

NEXT[FNC 29]

HKEY[FNC 17]

# constant,DM No.

I/O R

nnnnFOR

NEXT

nnnnmmmm

HKEY

#00000 to#65535

DM0000 toDM0999

TM00 to TM29

nnnn:0000 to 000910000 to 10415

:17000 to 17415

mmmm:10500 to 10915:

17500 to 17915

#00000 to#65535

DM0000 toDM1999

TM00 to TM29

5.0 to 20.0

1.7 to 2.3

71 to 370

3 (15)

1 (3)

5 (7)

Executes programbetween FOR & NEXTfor number of timesspecified by operand.

Represents end ofrepetition.

Reads 16-key data bytime-sharing andoutputs these data intospecial utility Rs 2900to 2915.

3-125

3-125

3-131

Page 71: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

KV-300 Series, KV-10/80

3-47

12

Chapter 2 Instructions

2.2 Instruction List

KV-300

Instruction Symbol Mnemonic Operand Operand value Exec.time(µs) Bytes

Function Page

16-BITCOUNTERCOMPARA-

TOR

16-BITCOUNTER

16-BITCOUNTERCOMPARA-

TOR

SUBROU-TINE CALL

SUBROU-TINE ENTRY

SUBROU-TINE

RETURN

REPEATSTART

REPEATEND

16-KEYINPUT

CTC

CTH

CTC

SBN[FNC 38]

RET[FNC 33]

FOR[FNC 16]

NEXT [FNC 29]

HKEY[FNC 17]

CALL [FNC 03]

#ddddd

CTCn

nnnnCTH1

#ddddd

CTCn

nn

CALL

nnSBN

RET

nnnnFOR

NEXT

nnnnmmmm

HKEY

n:Comparator

No.ddddd: #

preset value

Clocksource Rs

n:Comparator

No.ddddd: #

preset value

SubroutineNo.

SubroutineNo.

# constant,DM No.

I/O R

n: 0, 1ddddd:

#00000 to #65535

0005220022012202

n: 2, 3ddddd:

#00000 to #65535

00 to 99

00 to 99

#00000 to #65535DM0000 to DM9999

TM00 to TM29

nnnn:0000 to 000910000 to 10415

:17000 to 17415

mmmm:0500 to 050310500 to 10915

:17500 to 17915

3.85

3.16

1.15 to 1.45

1.55

16.50

2 (0)

4 (7)

2 (0)

2 (17)

2 (0)

1 (6)

3 (19)

1 (0)

5 (9)

Hardware-based comparatorbetween preset & currentvalues of high speed counter.This comparator is turned ONwhen these values are equal.

16-bit (0 to 65535) up-counter for clock pulses withinput response frequency of30 kHz.

Hardware-based comparatorbetween preset & currentvalues of high speed counter.This comparator is turned ONwhen these values are equal.

Executes subroutinespecified by operand.

Represents beginning ofsubroutine specified byoperand.

Represents end ofsubroutine.

Executes program betweenFOR & NEXT for number oftimes specified by operand.

Represents end of repetition.

Reads 16-key data by time-sharing and outputs thesedata into special utility Rs2900 to 2915.

3-204

3-204

3-204

3-122

3-122

3-122

3-125

3-125

3-131

Page 72: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

KV-300 Series, KV-10/802.2 Instruction List KV-300 Series,

3-48

2

Chapter 2 Instructions

2.2.3 Arithmetic InstructionsKV-10/16/24/40/80

KV-10/16/24/40/80 Instruction Symbol Mnemonic Operand Operand value

KV-10/16Operand valueKV-24/40/80

Exec.time(µs)

BytesFunction Page

DATAMEMORY

WRITE

TRIMMERSETTING

LOAD A

STORE A

COMPARE

ADD

SUBTRACT

MULTIPLY

DIVIDE

DW

TMIN[FNC 50]

@TMIN@[FNC 50]

LDA[FNC 23]

@LDA@[FNC 23]

STA[FNC 42]

@STA@[FNC 42]

CMP[FNC 04]

@CMP@[FNC 04]

ADD[FNC 00]

@ADD@[FNC 00]

SUB[FNC 46]

@SUB@[FNC 46]

MUL[FNC 28]

@MUL@[FNC 28]

DIV[FNC 11]

@DIV@[FNC 11]

#/$constant,DM No.

TrimmerNo.

R No.,C/T No.,DM/TM

No.,#/$

constant,#TMxx

R No.,C/T No.,DM/TM

No.,#/$

constant,#TMxx

DM/TMNo.,#/$

constant,#TMxx

DM/TMNo.,

#/$ No.,#TMxx

#00000 to#65535$0000 to$FFFF

DM0000 toDM0999

0

0000 to 2915T000 to T063C000 to C063CTH0 to CTH1

DM0000 toDM0999

TM00 to TM31#00000 to

#65535$0000 to$FFFF

#TM00 to#TM29

0500 to 19152100 to 2915T000 to T063C000 to C063

DM0000 toDM0999

TM00 to TM29#TM00 to#TM29

DM0000 toDM0999

TM00 to TM31#00000 to#65535

$0000 to$FFFF

#TM00 to#TM29

DM0000 toDM0999

TM00 to TM31#00000 to#65535$0000 to$FFFF

#TM00 to#TM29

#0000 to#65535

$0000 to$FFFF

DM0000 toDM1999

0 to 1

0000 to 6915T000 to T119C000 to C119CTH0 to CTH1

DM0000 toDM1999

TM00 to TM31#00000 to

#65535$0000 to$FFFF

#TM00 to#TM29

0500 to 19152100 to 6915T000 to T119C000 to C119

DM0000 toDM1999

TM00 to TM29#TM00 to#TM29

DM0000 toDM1999

TM00 to TM31#00000 to

#65535$0000 to$FFFF

#TM00 to#TM29

DM0000 toDM1999

TM00 to TM31#00000 to

#65535$0000 to$FFFF

#TM00 to#TM29

3.6 to 6.0

13.0 to 15.0

25.0 to 29.0

10.0 to 46.0

22.0 to 60.0

9.0 to 99.0

21.0 to 113.0

14.0 to 68.0

26.0 to 82.0

13.0 to 65.0

25.0 to 79.0

15.0 to 68.0

27.0 to 82.0

17.0 to 71.0

29.0 to 85.0

22.0 to 79.0

34.0 to 93.0

5 (6)

1 (4)

1 (11)

3 (5)

3 (12)

3 (5)

3 (12)

3 (5)

3 (12)

3 (5)

3 (12)

3 (5)

3 (12)

3 (5)

3 (12)

3 (5)

3 (12)

Writes constant intodata memory.

Converts trimmerrotation angle into 0to 249 and inputs itinto internal register.

Inputs value specifiedby operand intointernal register orinputs current valuewhen T/C is specifiedas operand.

Transfers content ofinternal register tolocation specified byoperand, or changespreset value when T/C is specified asoperand.

Compares content ofinternal register andvalue specified byoperand.

Adds content ofinternal register andvalue specified byoperand and inputsresult back to sameregister.Subtracts valuespecified by operandfrom content ofregister and inputsresult back to sameregister.

Multiplies content ofinternal register byvalue specified byoperand and inputsresult back to sameregister.

Divides content ofinternal register byvalue specified byoperand and inputsresult back to sameregister.

3-136

3-138

3-140

3-140

3-146

3-150

3-150

3-150

3-150

< DW >DMmmmm

nnnn

< TMIN >n

↑ TMIN >n

< LDA >nnnn

↑ LDA >nnnn

< STA >nnnn

↑ STA >nnnn

< CMP >nnnn

↑ CMP >nnnn

< ADD >nnnn

↑ ADD >nnnn

< SUB >nnnn

↑ SUB >nnnn

< MUL >nnnn

↑ MUL >nnnn

< DIV >nnnn

↑ DIV >nnnn

Page 73: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

KV-300 Series, KV-10/80

3-49

12

Chapter 2 Instructions

2.2 Instruction List

KV-10/16/24/40/80

Instruction Symbol Mnemonic Operand Operand valueKV-10/16

Operand valueKV-24/40/80

Exec.time(µs)

BytesFunction Page

AND A

OR A

EXCLU-SIVEOR A

SHIFTRIGHT A

SHIFTLEFT A

ROTATERIGHT A

ROTATELEFT A

COMPLE-MENT

INCRE-MENT

MEMORY

DECRE-MENT

MEMORY

MULTI-PLEXER

ANDA[FNC 01]

@ANDA@[FNC 01]

ORA[FNC 31]

@ORA@[FNC 31]

EORA[FNC 15]

@EORA@[FNC 15]

SRA[FNC 41]

@SRA@[FNC 41]

SLA[FNC 40]

@SLA@[FNC 40]

RRA[FNC 37]

@RRA@[FNC 37]

RLA[FNC 35]

@RLA@[FNC 35]

COM[FNC 05]

@COM@[FNC 05]

INC[FNC 19]

@INC@[FNC 19]

DEC[FNC 07]

@DEC@[FNC 07]

MPX[FNC 27]

@MPX@[FNC 27]

R No.,DM/TM No.,

#/$ No.,#TMxx

R No.,DM/TM No.,

#/$ No.,#TMxx

# constant

DM/TM No.

# constant

0000 to 2915DM0000 toDM0999

TM00 to TM31#00000 to#65535

$0000 to$FFFF

#TM00 to#TM29

0000 to 2915DM0000 toDM0999

TM00 to TM31#00000 to#65535

$0000 to$FFFF

#TM00 to#TM29

#01 to #16

DM0000 toDM0999

TM00 to TM29

#0 to #3

0000 to 6915DM0000 to

DM1999TM00 to TM31

#00000 to#65535

$0000 to$FFFF

#TM00 to#TM29

0000 to 6915DM0000 to

DM1999TM00 to TM31

#00000 to#65535

$0000 to$FFFF

#TM00 to#TM29

DM0000 toDM1999TM00

to TM29

11.0 to 64.0

23.0 to 78.0

11.0 to 63.0

23.0 to 77.0

10.0 to 63.0

22.0 to 77.0

11.0 to 28.0

23.0 to 42.0

10.0 to 28.0

22.0 to 42.0

12.0 to 30.0

24.0 to 44.0

12.0 to 29.0

24.0 to 43.0

5.0 to 6.0

17.0 to 20.0

12.0 to 15.0

24.0 to 29.0

14.0 to 17.0

26.0 to 31.0

24.0 to 25.0

36.0 to 39.0

3 (5)

3 (12)

3 (5)

3 (12)

3 (5)

3 (12)

2 (4)

2 (11)

2 (4)

2 (11)

2 (4)

2 (11)

2 (4)

2 (11)

1 (3)

1 (10)

3 (5)

3 (12)

3 (5)

3 (12)

1 (4)

1 (11)

ANDs each of 16 bitsof internal register andthat of value specifiedby operand, and inputsresult back to sameregister.

ORs each of 16 bits ofinternal register andthat of value specifiedby operand, andinputs result back tosame register.

EXCLUSIVE-ORseach of 16 bits ofinternal register andthat of valuespecified by operand,and inputs resultback to sameregister.

Moves content ofinternal registerserially left by valuespecified by operand.

Moves content ofinternal register seriallyright, allowing each bitthat leaves right end toenter carry bit and thenleftmost bit.

Moves content ofinternal register seriallyleft, allowing each bitthat leaves left end toenter carry bit and thenrightmost bit.

Inverts content ofeach bit in internalregister.

Adds 1 to content ofdata memoryspecified by operand.

Subtracts 1 fromcontent of datamemory specified byoperand.

Converts 4-bit data(specified byoperand) of internalregister into 16bitdata.

Moves content ofinternal registerserially right byvalue specified byoperand.

3-159

3-161

3-164

3-166

3-166

3-169

3-169

3-171

3-172

3-172

<ANDA>nnnn

↑ANDA>nnnn

< ORA >nnnn

↑ ORA >nnnn

<EORA>nnnn

↑EORA>nnnn

< SRA >#dd

↑ SRA >#dd

< SLA >#dd

↑ SLA >#dd

< RRA >#dd

↑ RRA >#dd

< RLA >#dd

↑ RLA >#dd

< COM >

↑ COM >

< INC >nnnn

↑ INC >nnnn

< DEC >nnnn

↑ DEC >nnnn

< MPX >#n

↑ MPX >#n

3-176

Page 74: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

KV-300 Series, KV-10/802.2 Instruction List KV-300 Series,

3-50

2

Chapter 2 Instructions

KV-300

Instruction Symbol Mnemonic Operand Operand value Exec.time(µs)

BytesFunction Page

KV-300

DATAMEMORY

WRITE

TRIMMERSETTING

LOAD A

STORE A

DW

TMIN [FNC 50]

@TMIN@[FNC 50]

LDA[FNC 23]

@LDA@[FNC 23]

STA[FNC 42]

@STA@[FNC 42]

#/$constant,DM No.

TrimmerNo.

R No.,C/T No.,DM/TM

No.,#/$

constant,#TMxx

R No.,C/T No.,DM/TM

No.,#/$

constant,#TMxx

nnnn:#0000 to #65535$0000 to $FFFF

DMmmmm:DM0000 to DM9999

0, 1

0000 to 00090500 to 17915T000 to T249C000 to C249CTH0 to CTH1

DM0000 to DM9999TM00 to TM31

#00000 to #65535$0000 to $FFFF#TM00 to #TM29

0500 to 19152100 to 17915T000 to T249C000 to C249CTC0 to CTC3

DM0000 to DM9999TM00 to TM29

#TM00 to #TM29

0.60 to1.40

5.10 to5.60

2.00 to5.70

0.30 to28.00

2.30 to30.00

0.20 to30.00

2.20 to32.00

5 (11)

1 (11)

1 (25)

3 (12)

3 (26)

3 (12)

3 (26)

Writes constant intodata memory.

Converts trimmerrotation angle into 0 to249 and inputs it intointernal register.

Inputs value specifiedby operand into internalregister or inputscurrent value when T/Cis specified as operand.

Transfers content ofinternal register tolocation specified byoperand, or changespreset value when T/Cis specified as operand.

3-136

3-138

3-140

3-140

< DW >DMmmmm

nnnn

< TMIN >n

↑ TMIN >n

< LDA >nnnn

↑ LDA >nnnn

< STA >nnnn

↑ STA >nnnn

KV-10/16/24/40/80

Instruction Symbol Mnemonic Operand Operand valueKV-10/16

Operand valueKV-24/40/80

Exec.time(µs)

BytesFunction Page

DEMULTI-PLEXER

TRANSFERBCD

TRANSFERBIN

ASCIICONVERT

REVERSEASCII

CONVERT

SQUAREROOT

DMX[FNC 12]

@DMX@[FNC 12]

TBCD[FNC 47]

@TBCD@[FNC 47]

TBIN[FNC 48]

@TBIN@[FNC 48]

ASC[FNC 02]

@ASC@[FNC 02]

RASC[FNC 32]

@RASC@[FNC 32]

ROOT[FNC 36]

@ROOT@[FNC 36]

28.0 to 30.0

40.0 to 44.0

19.0 to 21.0

31.0 to 35.0

18.0 to 20.0

30.0 to 34.0

8.0

20.0 to 22.0

12.0 to 14.0

24.0 to 28.0

102.0 to103.0

114.0 to117.0

1 (3)

1 (10)

1 (3)

1 (10)

1 (3)

1 (10)

1 (3)

1 (10)

1 (3)

1 (10)

1 (3)

1 (10)

Converts position ofhighest order bit with1 in internal registerinto 4-bit data.

Converts content ofinternal register (16-bit binary) into 4-digitBCD data.

Converts content ofinternal register (4-digit BCD) into 16-bitbinary data.

Converts content oflower order byte ofinternal register into2-digit ASCII code.

Converts 2-digit ASCIIcode into one bytedata.

Takes square root of 32-bit data (TM00: higherorder byte, internalregister: lower orderbyte) and inputs resultback to same register.

3-176

3-180

3-180

3-183

3-183

3-185

< DMX >

↑ DMX >

<TBCD>

↑ TBCD>

< TBIN >

↑ TBIN>

< ASC >

↑ ASC >

<RASC>

↑ RASC>

<ROOT>

↑ ROOT>

Page 75: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

KV-300 Series, KV-10/80

3-51

12

Chapter 2 Instructions

2.2 Instruction List

KV-300

Instruction Symbol Mnemonic Operand Operand value Exec.time(µs) Bytes

Function Page

COMPARE

ADD

SUBTRACT

MULTIPLY

DIVIDE

AND A

OR A

EXCLUSIVEOR A

CMP[FNC 04]

@CMP@[FNC 04]

ADD[FNC 00]

@ADD@[FNC 00]

SUB[FNC 46]

@SUB@[FNC 46]

MUL [FNC 28]

@MUL@[FNC 28]

DIV[FNC 11]

@DIV@[FNC 11]

ANDA[FNC 01]

@ANDA@[FNC 01]

ORA [FNC 31]

@ORA@[FNC 31]

EORA[FNC 15]

@EORA@[FNC 15]

DM/TMNo.,#/$

constant,#TMxx

DM/TMNo.,

#/$ No.,#TMxx

R No.,DM/TM

No.,#/$ No.,#TMxx

R No.,DM/TM

No.,#/$ No.,#TMxx

DM0000 to DM9999TM00 to TM31

#00000 to #65535$0000 to $FFFF#TM00 to #TM29

DM0000 to DM9999TM00 to TM31

#00000 to #65535$0000 to $FFFF#TM00 to #TM29

0000 to 00090500 to 17915

DM0000 to DM9999TM00 to TM31

#00000 to #65535$0000 to $FFFF#TM00 to #TM29

0000 to 00090500 to 17915

DM0000 to DM9999TM00 toTM31

#00000 to #65535$0000 to $FFFF#TM00 to #TM29

9.20 to36.00

11.20 to38.00

7.70 to35.00

9.70 to37.00

8.40 to35.00

10.40 to37.00

9.80 to37.00

11.80 to39.00

13.70 to41.00

15.70 to42.00

6.90 to33.00

8.90 to35.00

6.90 to33.00

8.90 to35.00

6.90 to33.00

8.9 to35.00

3 (12)

3 (26)

3 (12)

3 (26)

3 (12)

3 (26)

3 (12)

3 (26)

3 (12)

3 (26)

3 (12)

3 (26)

3 (12)

3 (26)

3 (12)

3 (26)

Compares content ofinternal register andvalue specified byoperand.

Adds content of internalregister and valuespecified by operandand inputs result backto same register.

Subtracts valuespecified by operandfrom content of registerand inputs result backto same register.

Multiplies content ofinternal register byvalue specified byoperand and inputsresult back to sameregister.

Divides content ofinternal register byvalue specified byoperand and inputsresult back to sameregister.ANDs each of 16 bits ofinternal register and thatof value specified byoperand, and inputsresult back to sameregister.ORs each of 16 bits ofinternal register andthat of value specifiedby operand, and inputsresult back to sameregister.

EXCLUSIVE-ORs eachof 16 bits of internalregister and that of valuespecified by operand,and inputs result back tosame register.

3-146

3-150

3-150

3-150

3-150

3-159

3-161

< CMP >nnnn

↑ CMP >nnnn

< ADD >nnnn

↑ ADD >nnnn

< SUB >nnnn

↑ SUB >nnnn

< MUL >nnnn

↑ MUL >nnnn

< DIV >nnnn

↑ DIV >nnnn

<ANDA>nnnn

↑ANDA>nnnn

< ORA >nnnn

↑ ORA >nnnn

<EORA>nnnn

↑EORA>nnnn

3-164

Page 76: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

KV-300 Series, KV-10/802.2 Instruction List KV-300 Series,

3-52

2

Chapter 2 Instructions

KV-300

Instruction Symbol Mnemonic Operand Operand value Exec.time(µs) Bytes

Function Page

SHIFTRIGHT A

SHIFTLEFT A

ROTATERIGHT A

ROTATELEFT A

COMPLE-MENT

INCREMENTMEMORY

DECREMENTMEMORY

MULTI-PLEXER

DEMULTI-PLEXER

SRA [FNC 41]

@SRA@[FNC 41]

SLA[FNC 40]

@SLA@[FNC 40]

RRA [FNC 37]

@RRA@[FNC 37]

RLA [FNC 35]

@RLA@[FNC 35]

COM [FNC 05]

@COM@[FNC 05]

INC[FNC 19]

@INC@[FNC 19]

DEC[FNC 07]

@DEC@[FNC 07]

MPX [FNC 27]

@MPX@[FNC 27]

DMX [FNC 12]

@DMX@[FNC 12]

# constant

DM/TMNo.

# constant

#01 to #16

DM0000 to DM9999TM00 to TM29

#0 to #3

10.80

12.80

10.80

12.80

12.00

14.00

12.00

14.00

6.10

8.10

7.70

9.70

7.70

9.70

7.30

9.30

6.70

8.70

2 (22)

2 (25)

2 (11)

2 (25)

2 (11)

2 (25)

2 (11)

2 (25)

1 (9)

1 (23)

3 (12)

3 (26)

3 (12)

3 (26)

1 (11)

1 (25)

1 (9)

1 (23)

Moves content ofinternal register seriallyright by value specifiedby operand.

Moves content ofinternal register seriallyleft by value specified byoperand.

Moves content ofinternal register seriallyright, allowing each bitthat leaves right end toenter carry bit and thenleftmost bit.

Moves content ofinternal register seriallyleft, allowing each bitthat leaves left end toenter carry bit and thenrightmost bit.

Inverts content of eachbit in internal register.

Adds 1 to content ofdata memory specifiedby operand.

Subtracts 1 from contentof data memoryspecified by operand.

Converts 4-bit data(specified by operand)of internal register into16- bit data.

Converts position ofhighest order bit with 1in internal register into4-bit data.

3-166

3-166

3-169

3-169

3-171

3-172

3-172

3-176

3-176

< SRA >#dd

↑ SRA >#dd

< SLA >#dd

↑ SLA >#dd

< RRA >#dd

↑ RRA >#dd

< RLA >#dd

↑ RLA >#dd

< COM >

↑ COM >

< INC >nnnn

↑ INC >nnnn

< DEC >nnnn

↑ DEC >nnnn

< MPX >#n

↑ MPX >#n

< DMX >

↑ DMX >

Page 77: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

KV-300 Series, KV-10/80

3-53

12

Chapter 2 Instructions

2.2 Instruction List

KV-300

Instruction Symbol Mnemonic Operand Operand value Exec.time(µs) Bytes

Function Page

TRANSFERBCD

TRANSFERBIN

ASCIICONVERT

REVERSEASCII

CONVERT

SQUAREROOT

TBCD[FNC 47]

@TBCD@[FNC 47]

TBIN[FNC 48]

@TBIN@[FNC 48]

ASC [FNC 02]

@ASC@[FNC 02]

RASC[FNC 32]

@RASC@[FNC 32]

ROOT[FNC 36]

@ROOT@[FNC 36]

13.20

15.20

14.00

16.00

8.50

10.50

6.80

8.80

77.70

79.70

1 (9)

1 (23)

1 (9)

1 (23)

1 (9)

1 (23)

1 (9)

1 (23)

1 (9)

1 (23)

Converts content ofinternal register (16-bitbinary) into 4-digit BCDdata.

Converts content ofinternal register (4-digitBCD) into 16-bit binarydata.

Converts content oflower order byte ofinternal register into 2-digit ASCII code.

Converts 2-digit ASCIIcode into one byte data.

Takes square root of 32-bit data (TM00: higherorder byte, internalregister: lower orderbyte) and inputs resultback to same register.

3-180

3-180

3-183

3-183

<TBCD>

↑ TBCD>

< TBIN >

↑ TBIN>

< ASC >

↑ ASC >

<RASC>

↑ RASC>

<ROOT>

↑ ROOT>

3-185

Page 78: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

KV-300 Series, KV-10/802.2 Instruction List KV-300 Series,

3-54

2

Chapter 2 Instructions

2.2.4 Interrupt InstructionsKV-10/16/24/40/80

KV-300

Instruction Symbol Mnemonic Operand Operand value Exec.time(µs) Bytes Function Page

INTERRUPTDISABLED

INTERRUPTENABLED

INTERRUPT

RETURNINTERRUPT

DI[FNC 08]

EI[FNC 13]

INT[FNC 20]

RETI[FNC 34]

R No.

ComparatorNo.

000 to 003

CTC0 to CTC3

3.20

5.80

40.00 to80.00

40.00 to80.00

60 to 100

1 (9)

1 (0)

1 (0)

1 (0)

1 (0)

Disables executionof interrupt.

Enables executionof interrupt.

Executes instructionsbetween INT andRETI at rising edgeof any of input 000 to003 or at falling edgeof 003.

Used with compara-tors CTC0 to CTC3and executesinstructions betweenINT and RETI.

Represents end ofinterrupt.

3-193

3-193

3-192

3-192

3-192

< DI >

< EI >

INTnnn

INTCTCn

RETI

KV-300

KV-10/16/24/40/80

Instruction Symbol Mnemonic Operand Operand valueKV-10/16

Operand valueKV-24/40/80

Exec.time(µs) Bytes

Function Page

INTERRUPTDISABLED

INTERRUPTENABLED

INTERRUPT

RETURNINTERRUPT

DI[FNC 08]

EI[FNC 13]

INT[FNC 20]

RETI[FNC 34]

R No.

ComparatorNo.

000 to 003

CTC0 to CTC3

3.0 to 4.6

3.0 to 4.6

35.0 to 48.0

35.0 to48.8

20.0 to23.0

1 (4)

1 (4)

1 (8)

1 (3)

Disables executionof interrupt.

Enables executionof interrupt.

Executes instruc-tions between INTand RETI at risingedge of any of input000 to 003 or atfalling edge of 003.

Used with compara-tors CTC0 to CTC3and executesinstructions betweenINT and RETI.

Represents end ofinterrupt.

3-193

3-193

3-192

3-192

3-192

< DI >

< EI >

INTnnn

INTCTCn

RETI

Page 79: Programming Installationmediasrv.co.za/uploads/media/5836.pdfThis manual describes the operation/function of all Keyence KV Series PLC. Note following conventions when you use. General

2.3 Convention Details

3-55

12

Chapter 2 Instructions

2.3 Convention DetailsIn this chapter, each instruction is described as follows:

2.4 Instruction Details

3-66

2

Chapter 2 Instructions

Example

Coding

Description

• Output relay 0500 remains ON after input relay 0000 turns OFF. Output relay0500 turns OFF when input relay 0001 turns ON.

• SET instruction sets a latch whereas RES instruction resets it.• RES instruction not only turns OFF relay coils but serves as a reset signal when

a timer or counter is used as an operand.

Note: The SET and RES instructions can be entered in any order. Note, however,that priority is given to the instruction that is entered last.In the above example, when both 0000 and 0001 are ON, RES has priority overSET, causing 0500 to remain OFF.

Tips

Differences between SET/RES and KEEP

Basically , SET/RES and KEEP ( p. 3-57 and p. 3-71) serve the same purpose.• SET and RES can be used separately. Therefore, RES can be placed before

SET.Another instruction may be placed between SET and RES.

• KEEP needs only three lines of program, therefore saving memory space whenused a number of times.

Operands

Key operation

SET: Set

RES: Reset

Turns ON specified relay when input is ONand enables this relay to remain ON.

Turns OFF specified relay, timer, or counterwhen input is ON.

SET1

RES0

nnnnRES

nnnnSET

0000

0001

0500SET

0500RES

Line No. Instruction Operand

0000 LD 0000

0001 SET 0500

0002 LD 0001

0003 OUB 0500

0001 00020001

0002 C000RES

#00100

00000C000

#00100

0000C000

0000

0001 0500SET

0500RES

0000

0001RES

KEEP

0500SETLD 0000

RES 0500

LD 0001SET 0500

LD 0000LD 0001KEEP 0500

SET1

RES0Operand ENT

R-SRCH Operand ENTR-SRCH

:

:

SET / RES

NEW KV KV-300 KV-10/16 KV-24/40/80

0500 to 1915 0500 to 1915 0500 to 1915 0500 to 19152009 2009 2009 2009

2100 to 17915 2100 to 17915 2100 to 2915 2100 to 6915T000 to T249 T000 to T249 T000 to T063 T000 to T119C000 to C249 C000 to C249 C000 to C063 C000 to C119

CTH0 to CTH1 (RES only)CTC0 to CTC3 (RES only)

InstructionDescribes the nameand brief function ofthe instruction.

Instruction keyRepresents the key orfunction No. for entry.

Ladder symbolRepresents the formof the instruction on aladder diagram.

MnemonicRepresents the instruc-tion in ladder language.

• Example• Timing diagram• DescriptionPerform programmingusing the given exampleto gain experience.

NoteDescribes the notesfor the instruction.

TipsDescribes hands-ontechniques for efficientprogramming.

OperandShows operands (elementNos.) that can be used forthe instruction.

Key operationDescribes the basic keyoperations on the handheldprogrammer. Set the modeswitch to PROGRAM.

CodingShows thecoding forthe givenexample.

* The above page is created for explanation purposes only.This page may be different from the actual page.