Programmable Controllers MELSEC-L series New Product Release · 2015-10-30 · 8 input channels...
Transcript of Programmable Controllers MELSEC-L series New Product Release · 2015-10-30 · 8 input channels...
RTD Input Module
L60RD8• 8 input channels with wider input ranges
• Reduced wiring time with no screw tightening
• Easier calibration
Flexible High-Speed I/O Control ModuleLD40PD01• Fast and stable I/O response
• Easy FPGA setup with dedicated configuration tool
• Supporting versatile applications
8-channel RTD input module with wide input ranges
Flexible high-speed I/O control module realizing stable and high-speed operation
Programmable ControllersMELSEC-L seriesNew Product Release No.351E
8 input channels with wider input rangesSingle L60RD8 can measure temperatures of up to 8 channels. With the number of supported channels doubled compared to before (L60MD4-G), space and cost savings can be realized. The input range is expanded to meet the DIN standards, GOST standards, and Pt1000 range in addition to Pt100, JPt100, and Pt50, bringing new application possibilities.
Reduced wiring time with no screw tighteningThe module is equipped with a spring clamp terminal block, which does not require screw tightening. This push-in type terminal block does not require any dedicated wiring tool and significantly reduces the installation time.
Easier calibrationMeasured temperatures can be easily calibrated towards the actual temperature using the sensor calibration function (shift function, 2-point sensor compensation function).
L60RD8
Just push into the terminal block without any tool.
8-channel RTD input module with wide input ranges has arrived!
■ SpecificationsItem L60RD8
Number of analog input channels 8 channels
OutputTemperature measured value −3280…15620
Digital operation value −32768…32767
Applicable RTD
9 typesPt1000, Pt100 (JIS C 1604−2013), JPt100 (JIS C 1604−1981), Pt50 (JIS C 1604−1981),
Ni500 (DIN 43760 1987), Ni120 (DIN 43760 1987), Ni100 (DIN 43760 1987), Cu100 (GOST 6651−2009, α=0.00428), Cu50 (GOST 6651−2009, α=0.00428)
Measured temperature range, accuracy*1 (Accuracy) = (Conversion accuracy) + (Allowable difference of RTD used)
Temperature detecting output current*11 mA Pt100, JPt100, Pt50, Ni120, Ni100, Cu100, Cu50
100 μA Pt1000, Ni500
Resolution*1 0.1°C
Conversion speed 40 ms/ch
Number of 2-point sensor compensationsettings
10000 times maximum
Isolation methodBetween input terminals and programmable controller power supply: Photocoupler
Between input channels: Non-isolation
Module size allocation 1
Number of occupied I/O points 16 points (I/O assignment: Intelligent 16 points)
External interface 24-point spring clamp terminal block
*1. For further details, please refer to "Programmable Controllers MELSEC-L series" catalog (L(LA)08159-E).
10.5℃ 50.0℃Actual temperature of the target (°C)
After calibration(digital calculated value)
Before calibration(measured temperature)
Measured temperature of RTD input module (°C)
The measured temperature of 10.8 to 50.7 (°C) is calibrated to be 10.5 to 50.0 (°C) by digital calculation. A temperature closer to the one input to RTD is obtained.
Gain value before calibration 50.7°C
Offset value before calibration 10.8°C
Calibrated gain value 50.0°C
Calibrated offset value 10.5°C
Fast and stable I/O responseHigh-speed response is realized with the hardware performance asynchronous to the CPU and control bus.
Easy FPGA setup with dedicated configuration tool*2
The design process associated with FPGA (HDL programming, logic synthesis, timing analysis) is no longer required, drastically reducing the development time. The configuration tool is also useful to pre-check the product operation, further reducing the startup time.
Supporting versatile applicationsThe flexible high-speed I/O control module realizes a wide range of controls including speed measurement, adjusted pulse output, ratio setting/distributed output, PWM control, and cam switch control.
LD40PD01
Flexible high-speed I/O control module realizing stable and high-speed operation!
• LD40PD01 is equipped with an external I/O interface and FPGA*1. This feature enables LD40PD01 to perform high-speed control, without being restricted by the CPU scan time and control bus performance. Dedicated configuration tool is also available to pre-check the product operation, further reducing the startup time.
• I/O response is stable as its processing speed only fluctuates in nanoseconds.
*1. Abbreviation of Field Programmable Gate Array. FPGA is an LSI that can be programmed after the manufacture.
Select Connect Parameter setup Debug
Check the signal status on a waveformSet up parameters of the blockDrag & drop a block Connect blocks
Trigger input
Measurement resolution 25 ns
Trigger input
ON 2 ms ON 6 ms
Input pulse
OFF timing
ON timing
Output 1
Output 1
Output 2
Output 3
Output 2
Output 3
An external input is used as a trigger to output a pulse. ON/OFF timing is adjusted for each output.
The module measures the sensor ON period from a pulse received from the sensor.
Passing time of conveyed products is accurately detected.
Pulse adjustment Speed measurement
■ Existing programmable controller (LCPU embedded I/O + interrupts)
■ Flexible high-speed I/O control module
Input
Output
Input
Output
10 μs/div 10 μs/div
Flexible high-speed I/O control module
SensorEncoder
ActuatorCamera (trigger)
Bus transmission
Input
Output
■ Specifications
ItemLD40PD01
DC Differential
Number of input points 12 points (5/24 V DC/differential)
Number of output points 8 points (5...24 V DC, 0.1 A/point) 6 points
Number of interrupts 8 interrupts
Input response time ≤ 1 μs (pulse input speed: Max. 200 kpulse/s) ≤ 1 μs (pulse input speed: Max. 8 Mpulse/s)
Output response time ≤ 1 μs (pulse input speed: Max. 200 kpulse/s) ≤ 1 μs (pulse input speed: Max. 8 Mpulse/s)
Resolution
25 ns
I/O response
1 μs
Intuitivesetting
*2. For further information on "Flexible High-Speed I/O Control Module Configuration Tool", please contact your local Mitsubishi sales representative.
Type Model Outline
RTD input module L60RD88 channels, RTD (Pt1000, Pt100, JPt100, Pt50, Ni500, Ni120, Ni100, Cu100, Cu50);resolution, 0.1°C; conversion speed, 40 ms/ch; 24-point spring clamp terminal block
Flexible high-speed I/O control module
LD40PD01
5 V DC/24 V DC/differential input: 12 pointsDC output: 8 points, counting speed switch setting 10k/100k/200k pulse/sDifferential output: 6 points, counting speed switch setting 10k/100k/200k/500k/1M/2M/4M/8M pulse/s (4 multiples)
External Dimension Diagrams
L60RD8 LD40PD01
28.5116.5
954 4
90
45(4
5)
4
45954 4
90
45(4
5)
4
DIN rail center
Unit: mm Unit: mm
DIN rail center
Product List
unit: mm unit: mm
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
www.MitsubishiElectric.com
1510[IP]New publication, effective Oct. 2015.
Specifications are subject to change without notice.
Country/Region Sales OfficeUSA ················· +1-847-478-2100Mexico ············· +52-55-3067-7500Brazil ················ +55-11-4689-3000Germany ·········· +49-2102-486-0UK ···················· +44-1707-28-8780Ireland ·············· +353-1-4198800Italy ·················· +39-039-60531Spain ··············· +34-935-65-3131France ·············· +33-1-55-68-55-68
Czech Republic ··· +420-251-551-470Poland·············· +48-12-630-47-00Sweden ············ +46-8-625-10-00Russia ·············· +7-812-633-3497Turkey ·············· +90-216-526-3990UAE ················· +971-4-3724716South Africa ····· +27-11-658-8100China ··············· +86-21-2322-3030Taiwan ············· +886-2-2299-2499
Korea ··············· +82-2-3660-9530Singapore ········ +65-6473-2308Thailand ··········· +66-2682-6522Vietnam ··········· +84-4-3937-8075Indonesia ········· +62-21-3192-6461India ················· +91-20-2710-2000Australia ··········· +61-2-9684-7777
For safe use• To use the products listed in this publication properly, always read the relevant manuals before use.
• Company names and product names used in this document are trademarks or registered trademarks of their respective companies.