CRHS #13Central Region High School #13 New Construction, DD + CD phase12/2005-9/2007
SITE PROJECTThe total program area is comprised of nearly 214,00 square feet, to serve a student population of 2,295. There will be a total of 85 classrooms. Consistent with the curricular goals of LAUSD, the program for this high school is divided into five Small Learning Communities (SLC’s) which act as independent communities of general and science classrooms and support functions.
DESIGN FACTORS There were several design issues that were identified gthrough the intial analysis of the project site and program that influenced the design direction:
- Maximizing the efficient use of a environmentally challenged site; - Mitigating the noise and site lines from the nearby rail line and San Fernando Road- Providing sense of campus community within a commercial manufacturing context- Maximizing design features and educational objectives;- Organizing the intersecting needs of service, bus drop off, and general parent drop off;- Providing access for the community to playfields and security to the school campus
SINGLE-FAMILY DWELLINGS
PUBLIC FACILITIES
COMMERCIAL MAN.
LIMITED COMMERCIAL
MULTI-FAMILY DWELLINGS
Glassell Park has a unique urban geographic profile with vistas to the surrounding hills, Silverlake, Elysian Park, Griffith Park and Mount Washington. Conveniently located adjacent to Interstates 5, as well as the 2, 110 and 134 freeways, Glassell is bordered by neighboring areas of Eagle Rock, Highland Park, Cypress Park, Elysian Park, Atwater Village and Glendalein the immediate proximity.
The project site, at 2050 San Fernando Road, is a 24 acre undeveloped parcel with adjacent light industrial to the north, east and west. The site also borders the Union Pacific Railwayand Los Angeles River to the south. One key point of selecting this site is its geographic proximity to the three area high schools for which the project has been designated to relieve overcrowding; Marshall High School to the west, Eagle Rock High School to the northeast and Franklin High School to the east will all transfer Glassell Park students back into the area to be educated within their community. Plans for a new park just adjacent southeast to the project site will provide needed recreation areas and fulfill a community goal of increasing green space for outdoor and sports activities.
Our site is challenged by several environmental factors, including the location’s proximity to the Railway and train yards present outdoor activity limitation zones. Overhead high tension electrical lines bisect our site to the north. When relocated, these lines present a further reduction in useable site area. Of the net 24 acres, 18.98 acres are accessible to school functions. Other site restrictions include a single site access point along San Fernando Road.With no other street frontage possible, a second access point is in under consideration. Theproject design for this new high school campus has taken all of these factors into account.
sergserg
1
23
10
19
16
11
12
13
9
5
8
4
3
2 19
17
20
25
26
27
13
15
14
28
22
10
16
11 12
9
5
8
4
32 6
7
13
15
14
1
6
67
7
14
15
17
18
18
20
20
21
21
23
2930 31 32 33
34
35
23
10
11
9
5
8
4
3
2
6
1
16
12
17
13
1514
4 4
6
7
10
16
11
12
9
5
8
4
3
2
17
6
713
15
14
1
18
19
20
2122
22
10
16
11
12
9
5 84
3
2
17
6
7
1315
14
1
5
8
10
10
10
10
18 19
20
1
1
1
1
1
1
1
11
11
1
1
1
1
11
1
1
1
11
1
1
1
2
3
4 56
7
8
88
88
9
10
11
11
11
12
12
12
12
10 7
7 10
4
45
5 6
6
9
9
3
3
2
22
2
3
3
4
4
7
710
10
6
6 5
5
9
9
24
34
9
9
9
9
9
18
21
8
6
Competition Gymnasium 1
Practice Gymnasium 2
Lobby/ Circulation 3
Ticketing / Concession 4
Data / PA 5
Gym Equipment Storage 6
Equipment Circulation Room 7
Mat Storage 8
Weight Room / Fitness 9
Aerobic / Dance 10
Wrestling 11
Therapy Room for Special Education 12
Faculty Office 13
Secured Storage 14
Faculty Shower / Locker / Toilet 15
First Aid / Cot Room 16
Lockers 17
Secure Lockers 18
Team Room 19
Girl’s & Boy’s Toilets 20
Showers (12) / Drying Area 21
Outside Equipment Storage 22
Janitor 23
Water Heater 24
Gymnasium
Plant Manager 25
Receiving (w/ Loading Dock) 26
Covered Exterior Receiving 27
Storage 28
Utility Area 29
Electrical 30
Tool Storage 31
Gardener’s Workroom 32
Outside Equipment Storage 33
Men’s & Women’s Changing Rooms 34
Flammable Storage 35
Plant Facilities
Computer / Reading / Stacks 1
Circulation Center 2
Book Process 3
Office 4
Conference Room 5
Fac. Toilet 6
Storage 7
Girl’s & Boy’s Toilets 8
Electrical 9
Janitor 10
Library
General Classroom 1
House Lead Office 2
Assistant Lead Office 3
Counselors Office 4
Waiting Area 5
Workstations 6
Conference Room 7
Faculty & Staff Work Room / Lounge 8
Faculty & Staff Toilets 9
Electrical / Data Rooms 10
Elevator 11
12
SLC 1-5
Flexible Music Room 1
Flexible Classroom 2
Instrumental Music 3
Practice Room 4
Music Work Room 5
Uniform Storage 6
Instrument Storage 7
Flexible Drama / Dance / Production 8
Girl’s & Boy’s Dressing / Toilet 9
Elec 10
Janitor 11
Performing Arts
Girl’s & Boy’s Restrooms 12
Multipurpose / Student Dining 13
Stage 14
Stagecraft 15
Control Room 16
Data / PA 17
Lobby / Concession / Tickets 18
Student Store 19
Storage 20
Dimmer Rack 21
Corridor 22
Multipurpose
Scramble Service 1
Kitchen 2
Faculty Dining 3
Girl’s & Boy’s Restrooms 4
Faculty Toilets 5
Janitor 6
Office 7
Toilet / Dress 8
Paper Storage / WH 9
Walk-In Freezer 10
Cold Strorage 11
Dry Strorage 12
Data 13
Electrical 14
Lunch Shelter 15
Trash & Recycling Collection 16
Main Electrical 17
Food Services
Reception / Public Waiting 1
Work Core / Clerical Area 2
Public Toilet 3
Principal’s Office 4
Principal’s Toilet 5
Control Room for LAN 6
Supply / Reprographics / Lounge Room 7
Administrative Restrooms 8
Police / Security Office 9
Offices 10
Conference 11
Waiting Area 12
Speech Therapy 13
Resource Specialist 14
Nurse 15
First Aid 16
Exam Room 17
Girl’s and Boy’s Cot 18
Toilet / Change 19
Janitor 20
Electrical 21
Administration
NORTH ELEVATION
PROGRAM
??????????
? ? ? ?? ? ? ? ?? ?
? ? ? ?? ? ? ? ?? ?
? ? ?? ? ? ? ?? ?
? ? ?? ? ? ? ?? ?? ? ?? ? ? ? ?? ?
? ? ?? ?? ? ?? ?
? ? ?? ?? ? ?? ?
????????????????????
20'-0"
SAFE DISPERSAL AREA FOR BLDGS. A & CTOTAL OCCUPANCY 4579@ 3 S.F. PER OCCUPANT x3
REQUIRED DISPERSAL AREA= 13,737 S.F.
10'-0"
20'-0"
20'-0"
20'-5
"
20'-0
"
SAFE DISPERSAL AREA FOR BLDGS. B,D & E
TOTAL OCCUPANCY
2,744
@ 3 S.F. PER OCCUPANT
x3
REQUIRED DISPERSAL AREA= 8,232 S.F.
77'-0
"
88'-5
"
SAFE DISPERSAL AREA FOR BLDG. G
TOTAL OCCUPANCY
2625
@ 3 S.F. PER OCCUPANT x3
REQUIRED DISPER SAL AREA= 7,875 SF
52'-9
"
27'-6"
37'-0"55'-0"
BLDG. ETYPE V-NR
30'-11/4"
31' -03/4"
33'-0
5/16
"
33'-2
9/16
"
FIRE PROTECTION SCHEDULE
C GNIDLIUB -RF -II EPYT:EPYT GNIDLIUB .I
HOURLY RATINGS:A. STRUCTURAL FRAME (COLUMNS AND PRIMARY FLOOR AND ROOF BEAMS) 2B. SECONDARY FLOOR BEAMS 2C. FLOORS 2D. ROOF 1E. SECONDARY ROOF BEAMS 1
II. BUILDING TYPE: TYPE V- ONE HOUR- BUILDING G AND TYPE II- ONE HOUR-BUILDING B
HOURLY RATINGS:1SMAEB YRAMIRP DNA SNMULOC -EMARF LARUTCURTS .A
B. FLOOR DECK, ROOF DECK AND SECONDARY BEAMS 1
III. FIREPROOFING NOT REQUIRED IN FOLLOWING AREAS:A. GYMNASIUM- ROOF AND SECONDARY MEMBERS ABOVE 25' NOT REQUIRED TO BE SPRAYEDB. PEDESTRIAN WALKWAYSC. BRACE FRAMES, TUBE STEEL AND GUSSET PLATES DO NOT REQUIRE FIRE PROTECTIONEXCEPT FOR 12" SPRAYOUT OF SAME THICKNESS PER CONNECTING MEMBER- THIS APPLIES TO BUILDINGS C, B, AND GD. EXTERIOR PROJECTIONS, OUTRIGGERS ARE NOT REQUIRED TO BE SPRAYED DUE TO DUCT WORK NOT BEING RATED
IV. FIRE RESISTIVE DESIGNS FROM U.L.A. ALL RATINGS FROM U.L. DESIGNS SHALL BE UNRESTRAINEDB. PRODUCT:MK-6/HY
ITEM DESIGN NOTESI. COLUMNS
277-XEGNALF EDIW177-XEPIP & EBUT
II. PRIMARY & SECONDARY BEAMS N 782III. FLOOR DECKS AND ROOF DECK- WITHMINIMUM 3 1/4" LW FOR 2 HOUR AND 2 1/2" LW FOR 1 HOUR D 925IV. FLOOR DECKS AT EXTERIOR BALCONIES, SPRAY WITH MIN. D 779THICKNESS 3/8" AT 1 1/2" DECKV. ROOF DECK WITH POLYISOCYANURATE INSULATION P- 732 FIRE
PROTECTION REQUIRED
VI. BEAMS SUPPORTING ABOVE DECK P -732SPECIAL INSPECTION IS REQUIRED USING UBC STANDARD 7-6.
COD
E A
NA
LYSI
S
WALL SECTIONS
NOT USED 1NOT USED 5NOT USED 9NOT USED 13 159
CLAHS #9 High School of the Performing Arts
HMC/Coop Himmelb(l)auNew Construction, CA phase2/2007-9/2009
photo by T. Bicksler
COURTYARD ELEVATION NORTH ELEVATION
SITE PLAN OVERALL
PORGRAM
Total Square Footage: 21
Music
Total Square Footage: 21
Dance
Total Square Footage: 21
Gymnasium
Total Square Footage: 21
Fine Arts
Total Square Footage: 21
Theatre/Perform. Arts
Total Square Footage: 21
Library
Total Square Footage: 21
Cafeteria
SCHOOL FOR THE FUTURE
copyright- Armin Hess copyright- Armin Hess
SMMUSDMalibu High School New Construction and Site Design, DD phase7/2009-10/2009
��
��
PHOTOVOLTAICCANOPY
INTENSIVE GREEN ROOF
PROGRAM LEGEND
1
2
3
4
5
LUNCH SHELTER
READING AREA/OLC
AMPHITHEATRE
FIRE LANE
SEATING
6 UNCOVERED WALKWAYS
7 GRAY WATER INFILTRATION
1
4 3
3
4
5 52
7
5
TUSDSouth High School Campus Improvements and Site Design, DD,SD,CD Phases9/2009-1/2010
TUSDWalteria Elementary School Campus Upgrade9/2009-12/2009
BUILDING D
BUILDING F
BUILDING GKINDERGARTENBUILDING
(N) KINDERGARTENCLASSROOM + RESTROOM
(N) OUTDOORAMPHITHEATRE
CAFETERIA
(N) BUILDING C
BUILDING B
PORTABLES TO REMAIN
LEGENDEXISTINGREPLACEMENT PORTABLES
WALTERIA ELEMENTARY SCHOOL TORRANCE UNIFIED SCHOOL DISTRICT
LANDSCAPEMODERNIZATIONNEW CONSTRUCTION
PORTABLES TOREMAIN
BUILDING A
(N) LIBRARY
ADMIN
1 - Markerboard 2 - Cork Board 3 - Millwork 4 - Rubber Base 5 - Accent Paint
Elevation A
Legend
Elevation B
Elevation C Elevation D
1
5
5
2
2 2
43
1 - Markerboard 2 - Cork Board 3 - Millwork 4 - Rubber Base 5 - Accent Paint
Elevation A
Legend
Elevation B
Elevation C Elevation D
1
5
5
2
2 2
43
KRHKent�eld Rehabilitation Hospital Facility Upgrade8/2011-11/2011
PT-1: PAINT FIELDDUNN EDWARDS DE6162“ANTIQUE LACE”
PT-2: PAINT ACCENT DUNN EDWARDS DE6164“CANARY ISLAND”
PT-3: PAINT ACCENT DUNN EDWARDS DE5528“WATERCRESS”
WC-1: WALL COVERINGTRIKES, YORK CONTRACT, STACY GARCIA SG1642 “ROYAL PALM”
RB-1: RESILIENT BASEJOHNSONITE, 4” MW-01-K“SNOW WHITE”
PT-3PT-2PT-1WC-1
RB-1
PARTITION UL# U305
2x STUDS AT 16" O.C.,SEE STRUCT.
5/8" TYPE "X" GYP. BD.CEILING
3" MIN. SOUND ATTENUATION
CONT. 2x SILL PLATE, SEESTRUCT.
2x DBL. TOP PLATE
(E) INTERIOR FOOTING.CONDITION VARIES, SEE STRUCT.
2x CJSEE STRUCT.
(E) 2x R.R.
5/8" GYP. BD. CEILING
5/8" TYPE "X" GYP. BD.@ EA. SIDE
R-30 INSULATION
(E) 2x FJ, SEE STRUCT.R-19 INSULATION
FINISH FLOORPER SCHEDULE (N) 3x BLOCKING, SEE STRUCT.
(E) (2) 2x TOP PLATE
(E) 2x4 P.T. SILL
2x LEDGER WITH 1/4" DIA.LAG SCREWS W/ 2" EMBEDAT ALTERNATE STUDS AT EA.SIDE
(2) 2x SILL PLATE
2x CRIPLE STUDS @ 16"O.C.
HEADER, SEE STRUCT.
(E) 2x DBL. TOP PLATE
2x DBL. STUD
(E) 2x PRESSURETREATED SILL PLATE
(E) 2x STUD
2x WOOD BLOCKING
TEMPORARY CONSTRUCTION BARRIERSTHE USE OF VISQEEN OF SIMILAR TYPE OF MATERIAL AS A TEMPORARYCONSTRUCTION BARRIER WHERE A FIRE SEPARATION IS REQUIRED SHALLNOT BE PERMITTED. A TEMPORARY BARRIER SHALL MEET THE SAME FIRERATING AS WOULD BE THE PERMANENT PARTITION.
WHERE A TEMPORARY PARTITION IS PLACED ACROSS A CORRIDOR ORIN ANY WAY BLOCKS AN EXIT OR CREATES A DEAD END, APPROVEDPLANS SHOWING THESE CONDITIONS SHALL BE APPROVED BY OSHPODFIRE MARCHAL, AREA COMPLIANCE OFFICER, LOCAL FIRE DEPARTMENT,ARCHITECT, INSPETOR OF RECORD AND THE OWNER.
EXAMPLE
REMODELED AREA
PARTITION TO BEDEMOLISHED
20 MIN. FIRE DOOR& STEEL FRAME - DOOR OPENS IN
ONE HOUR CORRIDOR
(N) 2x STUDS AT 16" O.C., SEE STRUCT.
5/8" GYP. BD. BOTH SIDES OF STUDS
3" MIN. SOUND ATTENUATION
(N) CONT. 2x SILL PLATE, SEE STRUCT.
5/8" GYP. BD. CEILING
(N) 2x DBL. TOP PLATE
FINISH FLOOR PER SCHEDULE
A-5028
(E) 2x FJ SEE STRUCT.R-19 INSULATION
2x CJ OVERLAP, SEE STRUCT.
R-30 INSULATION
(E) INTERIOR FOOTINGSEE STRUCT.
(N) 3x BLOCKING, SEE STRUCT.
(N) 2x BLOCKING, SEE STRUCT
(E) (2) 2x TOP PLATE(E) 2x4 P.T. SILL
2x4 CONT. AT EA. SIDE OFBRACE TO MATCH (E)
2x4 BRACE
1x6 OR 1x8 COLLAR TIE @ 4'-0"O.C. TO MATCH (E)
2x4 BLOCKING
10d NAIL MIN.(E) 2x ROOF RAFTER
FOR ALT. BRACING,SEE:
2x PURLIN, TO MATCH (E)
(E) 2x C.J.
(3) 16d T.N. MIN.
MIN
.
45.0
0°
2x4 BRACE @ 48" O.C.4x4 BRACE FOR LENGHTSOVER 6'
(3) 16d NAIL MIN.
(E) 2x R.R.
R-30 INSULATION
SIMPSON A34 JOIST TO WALLTOP PLATE AT BRACELOCATION
2x STUDS AT 16" O.C., SEE STRUCT.
1/2" PLYWOOD SEE STRUCTURAL
3" MIN. SOUND ATTENUATION
CONT. 3 x 6 SILL PLATE,, SEESTRUCT.
2x DBL. TOP PLATE
2x CJ, SEE STRUCT.
5/8" GYP. BD. CEILING
R-30 INSULATION
R-19 INSULATIONFINISH FLOOR, PER SCHEDULE
15/32" STRUCTURAL PLYWOODSHEATHING TO RUN ENTIRE
HEIGHT OF WALL W/ 8d NAILS @4" O.C. EDGE AND 12" O.C. FIELD
(N) ROOF PLYWOOD
(E) 2x R.R.
(E) 2x BLOCKING, FOR HEAD OFWALL ASSY, SEE STRUCT
WATER PROOFING MEMBRANEAND STUCCO FINISH TO MATCH (E)
A-50210
2x LEDGER WITH 1/4" DIA. LAGSCREWS W/ 2" EMBED AT
ALTERNATE STUDS
(N) 3" MIN. R-13 BATTINSULATION
NOTE:- MAINTAIN FIRE RATING WHERE REQUIRED.
- PATCH AND REPAIR (E) GYPSUM BOARD AS NEED IT
(N) 3x BLOCKING TO MATCH (E)WALL. FOR ANCHORAGE, SEE
STRUCT.
(N) 2x STUDS ALIGNED W/(E) CRIPPLES BELOW, SEE
STRUCT.
(N) 5/8" TYPE "X" GYPSUMBOARD
(N) PLYWOOD WHERE OCCURS,SEE STRUCT.
TO MATCH (E) FINISH
(N) WATER PROOFING PAPER
(N) 2x SILL, FOR ANCHORAGE,SEE STRUCT.
NOTE:- MAINTAIN FIRE RATING WHERE REQUIRED.
- PATCH AND REPAIR (E) GYPSUM BOARD AS NEED IT
(N) PLYWOOD WHERE OCCURS, SEESTRUCT.
TO MATCH (E) FINISH
(N) WATER PROOFING PAPER
(N) 3" MIN. SOUNDATTENUATION / BATT
INSULATION
(N) 3x BLOCKING TO MATCH(E) WALL. FOR ANCHORAGE
SEE STRUCT.
(N) 2x STUDS @ 16" O.C. TOMATCH (E) WALL, SEE
STRUCT. FOR LOCATIONS
(N) 5/8" TYPE "X" GYPSUMBOARD
(N) 3x MUD SILL, FOR ANCHORAGE SEESTRUCT.
(E) CONC. LANDING
SIMPSON A-34 FRAMING ANCHORS, TYP.
2X WOOD STUDS @ 16" O.C.
4x4 MIN. BLOCKING NAILER
NOTE:- MAINTAIN FIRE RATING WHERE REQUIRED.- PATCH AND REPAIR (E) GYPSUM BOARD AS NEEDED
PLYWOOD WHERE OCCURS, SEESTRUCT.
STUCCO FINISH TO MATCH (E)
WATER PROOFING MEMBRANETO RUN ENTIRE HT OF WALL ANDBELOW TO MIN 6" FTG. OVERLAP
3" MIN. SOUNDATTENUATION / BATT
INSULATION
2x STUDS @ 16" O.C. TOMATCH (E) WALL
5/8" TYPE "X" GYPSUMBOARD
3x SILL PLATE, SEE STRUCT
(E) PERIMITER DRAIN
(E) COURTYARD PAVING W/SEALED SURFACE
PLASTER WEEP SCREED
(E) 2x FJ, SEE STRUCT.
(E) EXTERIOR FOOTINGSEE STRUCT.
2x RING BEAM, SEE STRUCT.
(E) FJ SYSTEM TO REMAIN
2x STUDS AT 16" O.C., SEESTRUCT.
5/8" TYPE X GYP. BD. TO RUN FULL-HEIGHT OF WALL @ EA. SIDE
CONT. 2x SILL PLATE, SEE STRUCT.
5/8" TYPE X GYP. BD. @ TOPAND BOTTOM TO FORM
RATED TUNNEL ASSEMBLY,SEE PLANS FOR LOCATIONS
FINISH FLOOR PER SCHEDULE
+0'-0"FINISHED FLOOR
APPX +8'-0" TO BE V.I.F.B.O. HARD-LID CLG.
CORRIDOR
R30 INSULATION WHEREOCCURS
3" MIN SOUND ATTENUATION,SEE WALL TYPE
2x CEILING JOISTS, SEESTRUCT
NOTE:1. RATED WALL ASSEMBLIES TO COMPLY WITH PARTITION UL# U3052. NAIL PENETRATIONS AT RATED CONDITIONS REQUIRE COVERING WITHJOINT COMPOUND AND PAPER TAPE PER UL #U301 AND #U305
CONT. 2x TOP PLATE, SEE STRUCT.
2x LEDGER WITH 1/4" DIA.LAG SCREWS W/ 2" EMBED
AT ALTERNATE STUDS
2-1/2" 25 GAUGE STEEL CH STUDS @ 24" O.C.
CONT. STEEL J-RUNNER, SEE STRUCT.FOR CONN.
2x CJ, SEE STRUCT.
5/8" GYP. BD. CEILING
1" GYPSUM LINER PANEL @ SHAFT SIDE
R-30 INSULATION
FINISH FLOOR PER SCHEDULE
5/8" TYPE 'X' GYP BD W/ JOINTS FINISHED @NON-SHAFT SIDE
NOTE:RATED WALL ASSEMBLIES TO COMPLY WITH PARTITION UL# U415
25 GA STEEL J-RUNNER TRAK, FASTEN TO NAILER W/#12 SMS AT 12" O.C.,
(E) 2x R.R.
A-50214
PARTITION UL# U415
5/8 TYPE 'X' GYP BD. W/ JOINTS FINISHEDAT SHAFT SIDE
1" GYPSUM LINER PANEL @ SHAFT SIDE
25 GA. STEEL J-RUNNER TRAK, FASTEN TONAILER 12d WOOD SCREW AT 12" O.C.
(E) 2x WOOD ROOF RAFTER
2x WOOD ROOF JOISTS
2x WOOD BLOCKING
(E) PLYWOOD SHEATHING AND ROOF ASS'Y
MAX
.0'
- 0
3/4"
2-1/2" 25 GAUGE STEEL CH STUDS @ 24" O.C.
5/8" MAX FIRE-RESISTANT SEALANT COMPOUNDMIN
.0'
- 0
1/2"
3/8 -1/2" MIN. FIRE-RESISTANT SEALANT COMPOUND
PARTITION UL# U415
WALL TAG SCHEDULE
WOOD
WALL TAG MATERIAL FIRE RATING AND UL# STUD SIZE
W1.4 1-HR UL# U305
WOOD NON-RATED
DETAR-NONDOOW
LIGHT-GAUGE STEEL
W0.4
W0.6
J1.2
4"
4"
6"
1-HR UL# U415 2 1/2"
NOTE:FOR BEARING WALL LOCATIONS, SEE STRUCTURAL DWGS
(N) 2x STUDS AT 16" O.C., SEE STRUCT.
5/8" GYP. BD. BOTH SIDES OF STUDS
3" MIN. SOUND ATTENUATION
(N) CONT. 2x SILL PLATE, SEE STRUCT.
5/8" GYP. BD. CEILING(N) 2x DBL. TOP PLATE
FINISH FLOOR PER SCHEDULE
(E) 2x FJ SEE STRUCT.
R-19 INSULATION
2x CJ, SEE STRUCT.R-30 INSULATION
TOP OF STUD TO EXTEND BEYOND PROFILEOF CJ
__ of __
Checked By:Drawn By:OSHPD No.:
PDA Project No.:
Project:
Client:
Stamp:
D r a w i n g T i t l e :
Date:Phase:
Revisions:
Drawing No.:
Agency Approval:
KentfieldRehabilitation HospitalFacility Upgrade
Vibra Healthcare
1125 Sir Francis Drake Blvd.Kentfield, CA 94904(415) 485-3683
4550 Lena DriveMechanicsburg, PA 17055(717) 591-5733
348-10-04010/19/2011
CD
08 / 15 / 11 DD Submittal
13
-
10 / 19 / 11 CD Submittal
C:\T
emp\
KRH-
Facil
ity U
pgra
de-R
C11.1
0.18.r
vt10
/18/20
11 1:
56:1
6PM
A-502
WALL TYPES
CheckerAuthor
Auth
or
SCALE: 3/4" = 1'-0" 51-HR RATED PARTITION
SCALE: 1/2" = 1'-0" 2WOOD FRAMING DETAIL
SCALE: 12" = 1'-0" 1CONSTRUCTION BARRIER
SCALE: 3/4" = 1'-0" 7BEARING PARTITION WALL
SCALE: 1" = 1'-0" 8BEARING WALL ALT. BRACE
SCALE: 3/4" = 1'-0" 9SHEAR WALL @ COURTYARD
SCALE: 1 1/2" = 1'-0" 12EXTERIOR WALL - WINDOW INFILL
SCALE: 1 1/2" = 1'-0" 11EXTERIOR WALL - DOOR INFILLSCALE: 3" = 1'-0" 3WOOD STUD BACKING PLATE
SCALE: 1 1/2" = 1'-0" 10SHEAR WALL SILL DETAIL
SCALE: 1 1/2" = 1'-0" 15RATED CEILING AT CORRIDOR
SCALE: 3/4" = 1'-0" 131HR RATED NON-BEARING SHAFTWALL
SCALE: 3" = 1'-0" 14HEAD OF WALL-1HR RATED SHAFTWALL
J.1.2
W.0.4W.0.6
SCALE: 3/4" = 1'-0" 6NON BEARING PARTITION WALL
W.0.4W.0.6
(E) ROOF
AREA TO BE PATCHEDAND REPAIRED TO
MATCH (E) ROOF
AC UNIT, SEE MEPDWGS.
PROFILE OF AC UNITRAISED PLATFORM, MIN. 6"FROM PERIMETER OF UNITEDGE, FOR FRAMING INFO
SEE STRUCT. DWGS.
2
A-501
6"
BUILT-UP CRICKET ON HIGH-SIDE OF CURB TO DIRECT
WATER FLOW
SUPPLY AND RETURN AIRDUCTS WITH 20"x14"
THROUGH- ROOFPENETRATIONS, SEE DETAIL
4/A-501 AND STRUCTURALFRAMING PLAN
20 GA. SHEET MTL COUNTERFLASHING W/DRIP EDGE W/ CONT. CAULK BEAD
BLOCKING W/ A34 FRAMINGANGLES, SEE STRUCT DWGS.
HVAC UNIT
3" FIBER CANT STRIP
WATER-PROOF MEMBRANE WRAPPEDOVER ENTIRE PLATFORM, SEE SPECS
(E) ROOF RAFTERS
4x BLOCKING W/ SIMPSONA35 CLIPS @ 24" O.C., SEE
STRUCT.
RIGID INSULATION, MATCH (E)ROOF ASSEMBLY
3x3x12 GA. CLIP W/ 1/4" DIA. WOOD LAGSCREW W/ 2" EMBED & (3) #10 SMS @UNIT RAIL, SEE STRUCT.
2x PER PLAN, SEE STRUCT.
(E) ROOF SHEATHINGCONT. PLYWOOD SHEATHING ALONGPROFILE OF PLATFORM
4x WOOD BLOCKING CURB, SEE STRUCT.
(E) BASE FLASHINGWATERPROOF MEMBRANE, MIN6" PROFILE FOR OVERLAP WITH(N) MEMBRANE AT CURB
MIN.6"
CLASS 'A' ASPHALT SHINGLESTO MATCH EXISTING ROOFFINISH
PROFILE OF CRICKET BEYOND
2X PER PLAN, SEE STRUCTURAL FRAMING PLAN
3x3x12 GA. CLIP W/ 1/4" DIA WOOD LAGSCREW W/ 2" EMBED & (3) #10 SMS
4x PER PLAN, SEESTRUCTURAL FRAMING PLAN
SIMPSON A35 CLIPS @ 24" O.C.
SISTER ROOF RAFTER AND 3x BLOCKING PER PLAN, SEE STRUCT.
2x STUDS @ 24" O.C.
SIMPSON WOOD SILL PLATE, SEESTRUCT.
20 GA. SHEET MTL FLASHING W/ DRIP EDGE,TYP. @ EA. SIDE
3" FIBER CANT STRIP
WATER-PROOF MEMBRANEWRAPPED OVER ENTIRE PLATFORM
HVAC UNIT A-5013
2x4 BRACE , FOR RAFTER SUPPORT SEE STRUCT.4x AND 2x PLATFORM
FRAMING, SEE STRUCT.
3" CONT. FIBERCANT STRIP
CLASS 'A' WATERPROOFROOF MEMBRANE W/ MIN 6"OVERLAP
TAPERED RIGID INSULATION
MECHANICAL DUCT, SEEMECH. DWGS.
24 GA. GALVANIZED FLASHING@ EA. SIDE
2x WOOD CURB FASTENEDTO (E) ROOF SHEATHING W/A34 CLIPS (2) EA. END (8TOTAL) & #8 SCREWS
PLYWOOD SHEATHING
5/8" TYPE 'X' GYP BD. @ EA.SIDE OF DUCT (E) CEILING ASSEMBLY WHERE
OCCURS, SEE REFLECTEDCEILING PLANS
2x CURB
(E) 2x WOODFRAMING
MECH. DIFFUSER, SEE MEPDWGS.
8 1/2"
24 GA. GALVANIZED FLASHINGCAP
3" CONT. FIBER CANTSTRIP
CLASS 'A'WATERPROOF ROOF
MEMBRANE
TAPERED RIGIDINSULATION
EXHAUST FAN, SEE MECH.DWGS. MAKE-UP AIR, SEEMECH. DWGS - WHERE OCCURS
2x WOOD CURB W/ A34 CLIPS EA.END TO 2X CROSS MEMBERS,FASTEN TO (E) ROOF SHEATHINGW/ A34 (2) EA. END (8 TOTAL) & #8 x1/2" SCREWS
(E) PLYWOODSHEATHING
5/8" TYPE 'X' WATER & MOLD-RESISTANT GYP BD. @ EA. SIDE OF
DUCT
(E) CEILING ASSEMBLY WHEREOCCURS, SEE REFLECTEDCEILING PLANS
2x CURB
(E) 2x WOOD FRAMING
MECH. DUCT, SEE MEP DWGS.
9-1/4
".
WRAP ROOFING MEMBRANE UP &OVER CURB FASTEN W/ #8 WDSCREWS & NEOPRENE WASHERS@ 4" O.C.
#14 SELF TAPPING SHEET MTL.SCREW W/ NEOPRENE FACEWASHER @ 4" O.C.
24 GA.GALVANIZED FLASHING CAP
TABLE OF ALLOWABLE SPANS FOR CEILING JOISTS
UNBRACED BRACE ATMIDSPAN
BRACE AT1/3 POINT
18 GA. X 3 5/8" AT 12" O.C.18 GA. X 3 5/8" AT 12" O.C.18 GA. X 3 5/8" AT 12" O.C.
9' - 0"8' - 6"7' - 6"
12' - 9"12' - 0"10' - 9"
15' - 9"14' - 6"13' - 3"
18 GA. X 1" METAL STRAP OR1" CHANNEL CONT. FLANGEBRACE. #6 SMS AT EA. JOIST,SEE TABLE BELOW FOR JOISTSPANS
2 #10 SMS @ EA. STUD
18 GA. METAL STUDS. FORSPACING SEE TABLE BELOW
TRACK BACK'G ATBRACE SPLICE
1 1/2" FL. CONT TRACK W/ #10SMS EA. FL. EA. STUD. WIDTH &THICKNESS TO MATCH JOIST 918 GA. MIN.)
JOINT TREATMENT
PARTITION TYPE PERPLANS5/8" TYPE "X" GYP. BD.
RECESSED LIGHT FIXTURE,SEE ELECT
(N) 2x6 CEILING JOIST @ MAX.16" O.C.ADD BLOCKING AS REQUIRED
MIN (2) #6 x 1 1/2" SMS ATEACH SIDE (TOTAL 4)
(N) 2x6 MIN. BLOCKING AT EACHSIDE OF FIXT. (TOTAL 2)
5/8" TYPE 'X' GYP BOARD CEILINGTO WRAP AROUND ENTIRE
FIXTURE @ RATED CORRIDOR
2x4 BLOCKING W/ MIN. (2) 10D TOENAILS AT EACH END, TYP. @ EA. SIDE
MIN (2) #6 x 1 1/2" SMS AT EACHCORNER OF FIXTURE, TYP. (TOTAL 4)
(N) 2x6 CEILING JOIST@ MAX. 16" O.C. TYP.
SURFACE-MOUNTED LIGHT FIXTURE, SEEELECT
RECESSED FIXTURE
SURFACE-MOUNTED FIXTURE
2x NAILER LAY DOWN @ 16"O.C.
2 1/8"
5/8" TYPE 'X' GYP. BD., PATCH,REPAIR AND RE-PAINT WHERENEEDED
2 1/8"
2"
VARIES
VARIES
A
B
WALL-MOUNTED FIXTUREC
(N) OPERABLE PATIENT-ROOMFIXTURE
5/8" TYPE 'X' GYP. BOARD
(6) #6 x 1 1/2" SMS AT PRE-DRILLEDLOCATIONS ON BACKING PLATE
3 1/4"
MIN. 20 GA. 33 ksi MIN. BACKINGPLATE
3x6 WOOD BLOCKING, SEE 3/A-502 FORBACKING DETAIL
VARIES
5"
2" MAX. TYP. AT EA. SIDE
__ of __
Checked By:Drawn By:OSHPD No.:
PDA Project No.:
Project:
Client:
Stamp:
D r a w i n g T i t l e :
Date:Phase:
Revisions:
Drawing No.:
Agency Approval:
KentfieldRehabilitation HospitalFacility Upgrade
Vibra Healthcare
1125 Sir Francis Drake Blvd.Kentfield, CA 94904(415) 485-3683
4550 Lena DriveMechanicsburg, PA 17055(717) 591-5733
348-10-04010/19/2011
CD
08 / 15 / 11 DD Submittal
13
-
10 / 19 / 11 CD Submittal
C:\T
emp\
KRH-
Facil
ity U
pgra
de-R
C11.1
0.18.r
vt10
/18/20
11 12
:22:
38PM
A-501
ROOF & CEILINGDETAILS
CheckerAuthor
09/08/11
Auth
or
SCALE: 1/4" = 1'-0" 1TYPICAL HVAC UNIT DETAIL
SCALE: 1 1/2" = 1'-0" 3MECHANICAL EQUIPMENT PAD
SCALE: 1 1/2" = 1'-0" 2MECHANICAL PLATFORM SECTION
SCALE: 1 1/2" = 1'-0" 4DUCT PENETRATION
SCALE: 1 1/2" = 1'-0" 5ROOF DTL - EXHAUST FAN
SCALE: 3" = 1'-0" 6SUSPENDED GYPSUM CEILING
SCALE: 1 1/2" = 1'-0" 8EMERGENCY LIGHT ANCHORAGE
FAIR OAKS REGENCY PARKRegency Park Senior Living New Construction, SD Phase11/2011 - 12/2011