ISAC ENTERPRISES (Industrial Safety & Automation Components)
Regi. Office: New Sumthana, Triratna Society, Ta: Bhadrawati, Dist. – Chandrapur - 442 902, Maharashtra, India. Contact: Mobile:
+91 9270367704, Email ID – [email protected], [email protected], www.isac.co.in
Dear Customers,
ISAC Enterprises is a purely trading company established in 2013 and is pleased to introduce
you the following products useful for industrial safety & automation applications.
Stand alone coded electronic safety switches
No additional safety relays are required to reach SIL2 Cat.3/SIL3 CAT.4
Stand alone non contact coded safety switches. Auto control integrated.
Model: AMX • PL=d Acc. to EN ISO 13849-1
• Cat.3 acc. to EN ISO 13849-1
• SIL 2 acc. to EN62061
• 1 NO + 1 NC (AMX3) 2NO +1NC
(AMX5)
• Switching distance: 10mm • Led status display of the correct
code recognition
• Temperature -20°C to +60°C /IP67
• Double mounting brackets
• Housing in Polyamide6 or 316L Stainless Steel
Stand alone non contact coded safety switches with cylindrical design
Model: 7SSR24V • PL = c Acc. to EN ISO 13849-1
• Cat.1 acc. to EN ISO 13849-1 • 2NO 1A/48V + 1NC 24V/1A
• Switching distance: 10mm
• Led status display of the correct
code recognition
• Temperature -20°C to +60°C /IP67
• CuNI housing M30x1,5
• Cylindrical design
Stand alone non contact coded safety switches with coded keys. Avoid an
operator to be trapped inside a dangerous area.
Model: AMX 5 • PL=d Acc. to EN ISO 13849-1
• Cat.3 acc. to EN ISO 13849-1
• SIL 2 acc. to EN62061
• 2NO 2A/48V + 2NC 24V/250mA
• Switching distance: 10mm
• Led status display of the correct code
recognition
• Temperature -20°C to +60°C /IP67
• Double mounting brackets & M12 built
in M12 connector 8pin.
• Housing in Polyamide6
• Prisoner key : can work in key transfert with C4CK.
Stand alone non contact coded safety switches with a reduced size.
Model: OPTO2S • PL = c Acc. to EN ISO 13849-1 • Cat.1 acc. to EN ISO 13849-1
• 2NO 250mA/48V
• Switching distance: 10mm
• Led status display of the correct code
recognition
• Temperature -20°C to +60°C /IP67
• Double mounting brackets
• Housing in Polyamide6
• Miniature series
• Shock stress : 75G
• No discrepancy between the lines
Non-Stand alone coded electronic safety switches
Require safety relay to reach SIL2 Cat.3/SIL3 CAT.4
Small and cylindrical coded safety switches
Model :ANATOM M18 • PL = e Acc. to EN ISO 13849-1
• Cat.4 with AWAX acc to EN ISO13849-1
• 2NO + 1 NC PNP
• Switching distance: 6mm
• Temperature -20°C to +60°C /IP67
• CuNi Housing
• M12 output
• Unlimited life expectancy
• Auxiliary for automation control or light
• M18 Cylindrical
Non contact coded safety switches with a reduced size.
Model: OPTOPUS DEC • PL = e Acc. to EN ISO 13849-1
• Cat.4 with AWAX acc to EN ISO13849-1
• 2NO + 1 NC PNP
• Switching distance: 5mm
• Led status display of the correct code
recognition
• Temperature -20°C to +60°C /IP67
• Double mounting brackets
• Unlimited life expectancy
• Housing in Polyamide6 or 316L Stainless Steel
• Miniature series
ISAC ENTERPRISES (Industrial Safety & Automation Components)
Regi. Office: New Sumthana, Triratna Society, Ta: Bhadrawati, Dist. – Chandrapur - 442 902, Maharashtra, India. Contact: Mobile:
+91 9270367704, Email ID – [email protected], [email protected], www.isac.co.in
Non contact coded safety switches with NC aux. output ( 78S) or NO
aux.output (98S)
Model:ANATOM 78S - 98S • PL = e Acc. to EN ISO 13849-1
• Cat.4 with AWAX acc to EN
ISO13849-1
• 78S : 2NO + 1 NC 250mA PNP
• 98S : 2NO + 1 NO 250mA PNP
• Switching distance: 10mm
• Led status display of the correct
code recognition
• Temperature -20°C to +60°C
/IP67 or IP69K
• Double mounting brackets
• Housing in Polyamide6 or 316L Stainless Steel
• Available with cable , mkt or M12 output
Non contact coded safety switches with a reduced size.
Model: OPTOPUSC M8 • PL = e Acc. to EN ISO 13849-1
• Cat.4 with AWAX acc to EN ISO13849-1
• 2NO + 1 NC PNP
• Switching distance: 4mm
• Led status display of the correct code
recognition
• Temperature -20°C to +60°C /IP67
• Double mounting brackets
• Housing in Polyamide6
• Built in M8 connector
• Switching time 500 us
Electromagnetic Holding in 316L Stainless Steel Safety Switches.
Stand alone non contact coded safety switches with 4kg permanent
holding force.
Model : BOSTER • PL=d Acc. to EN ISO 13849-1
• Cat.3 acc. to EN ISO 13849-1
• SIL 2 acc. to EN62061
• Permanent Holding Force 4KG
• Decoding with Acotom3®
• Relay contacts 2A/48V with self
control
• Auxiliary for automation control or
light
• 316L Stainless STEEL housing
• Laser writing ( no INK)
• Temperature -20°C to +60°C /IP67
• No additional safety relay necessary
Non contact coded safety switches with 2kg permanent holding force
designed to work in hard conditions.
Model: EPINUS 2 KGS • PL = e Acc. to EN ISO 13849-1
• Cat.4 with AWAX acc to EN ISO13849-1
• Permanent Holding Force 2 Kg
• Decoding with Acotom2®
• Auxiliary for automation control or
light : PNP/ NC / 250 mA
• 316L Stainless STEEL housing
IP69K
• Laser writing ( no INK)
• Temperature -20°C à +90°C (EPINUS 2K)
• TEFLON Output
• Handle version with M5 screw (Epinus 2K72) :(EPINUS 2K 72)
Non contact coded safety switches for high temperature
Model: TRITHON • PL = e Acc. to EN ISO 13849-1
• Cat.4 with AWAX acc to EN
ISO13849-1
• Decoding withAcotom®2
• Unlimited life expectancy
• Misalignment : +- 30° rotation
• Using temperature : -25°C to +110°C
• Detection/hysteresis : 9 /+2 (mm)
• IP69K • Connection with cable Teflon
• Laser writing ( no INK)
• Auxiliary for automation control or light
• N version : NPN/ NC /1A
• standart version : PNP/NC/1A
• 316L Stainless STEEL housing
Non contact coded safety switches with 4kg permanent holding force
designed to work in hard conditions.
Model: EPINUS 4 KGS • PL = e Acc. to EN ISO 13849-1
• Cat.4 with AWAX acc to EN ISO13849-1
• Permanent Holding Force 4KG
• Decoding with Acotom®2
• Auxiliary for automation control or light :
PNP/ NC / 250 mA
• 316L Stainless STEEL housing IP69K
• Laser writing ( no INK) • Temperature -20°C à +60°C
• Cable or MKT version
ATEX Approved Safety switches
ISAC ENTERPRISES (Industrial Safety & Automation Components)
Regi. Office: New Sumthana, Triratna Society, Ta: Bhadrawati, Dist. – Chandrapur - 442 902, Maharashtra, India. Contact: Mobile:
+91 9270367704, Email ID – [email protected], [email protected], www.isac.co.in
Model: RDX8 • Access control in area 2 or area 22
• Non contact coded safety switches
with low hysteresis non contact
coded safety switches with low
hysteresis
• Auto control built in
• Must be use with an intrinsic zener
barrier with dual channel such as
our ZRX8 or Awax26XXLEEX
• Up to 30 switches in series
• Dual channel for more safety
• 2 output NO& 1 NC 50 mA 30 V max
Model: ANATOM78S PL EEX • Access control in area 2 or area 22 (
Polyamide version )
(ANATOM 78S PL EEX)
• Access control in area 1 or area 21
( Stainless version)
ANATOM 78S INOX EEX)
• Non contact coded safety switches with
low hysteresis
• System Eex SYST (iaIICT4) & ISO 13849-1
• Compliant with ATEX and machine safety
• Built in zener barrier ,
• Power Supply 24Vac/dc
• Output 3 channel NO + 1 NC 8A /250V
• Temperature -20+ 40 °C
• Gas : T4
• Dust : 135°C
Model:AWAX26XXL EEX 3 • Compliant with ATEX and machine safety
• Output 3 channel NO + 1 NC 8A /250V
• Built in zener barrier
• Compliant with EN 50020 & ISO 13849-1
• Compatible with aluminum profile
• Power supply 24 Vac/dc
Electromagnetic Holding with built-in safety switch
Model: SUPERMAGNET 1 • Performance Level (PL) = d
• Safety category = with Awax
• Steel Magnet (R version IP54 ) : locking
when energized , force 40 daN
• Stainless Steel Magnet (R version IP65)
locking when energized , force 58 daN
• Steel Magnet (E version IP54 ) : locking
when energized , force 20 daN
• Steel Magnet (E version IP65 ) : locking when energized , force 40 daN
• Polar plate on 360 ° . Can be fixed if chosen
Model: SUPERMAGNET 2 • Performance Level (PL) = d
• Safety category = with Awax
• Stainless Steel Magnet (R version
IP65 ) : locking when energized ,
force 116 daN
• Stainless Steel Magnet (E version
IP65 ) : locking when energized ,
Force 80 da
• Closed door detection using Acotom Process
• Two channels for control on Awax
• Stainless steel 316 L version. Laser printing ( no ink)
• Polar plate on 360 ° . Can be fixed if chosen
• M 12 connector in resistant metal
ISAC ENTERPRISES (Industrial Safety & Automation Components)
Regi. Office: New Sumthana, Triratna Society, Ta: Bhadrawati, Dist. – Chandrapur - 442 902, Maharashtra, India. Contact: Mobile:
+91 9270367704, Email ID – [email protected], [email protected], www.isac.co.in
RFID coded Safety switches
Stand alone non contact coded safety switches using RFID. Auto
control integrated.
Model: XORFS • Performance Level (PL) = c
• safety category = with awax
• RFID system , not possible to
fraud
• Can be use in a metallic
environment
• Self control built-in. No safety
relay required • 2 NO
• Aux. Output : NC PNP 400mA
• Housing in Polyamid 6
• Self learning when first use
• 16 billion code possibility
• RFID 125 KHz
Stand alone non contact coded safety switches using RFID.
Auto control integrated.
Model: AMXRS • Performance Level (PL) = c
• Safety category = 3 & Sil 2
• RFID system , not possible to fraud.
• Can be use in a metallic environment
• Self control built-in. No safety relay
required
• 2 NO /2A 48V
• Aux. Output : NC PNP 400mA • Housing in Polyamide 6
• Self learning when first use
• 16 billion code possibility
• RFID 125 KHz
RFID Access control
Stand alone access control for jewellery, closet, office access….
Model: XR530
• RFID KEY avalaible with leather key ring
• locking system command
• Door entry control
• 2 alarm output , 1 is dedicated for vandalism
• Power Supply 12 V DC à 30 V DC
• Stand alone Access control
• Double mounting brackets
• Over 16 billions Codes
• RFID BADGES can be make on demand
Model: AXKEF CE10
• RFID reading to manage 8 different area or authorizations with
Self learning.
• Application in Buildings
• Can be used in offices, public space, patrol control….
• Application for industries
• Access control on machine, robots…
• Control of containing
• Automatic sorting
ISAC ENTERPRISES (Industrial Safety & Automation Components)
Regi. Office: New Sumthana, Triratna Society, Ta: Bhadrawati, Dist. – Chandrapur - 442 902, Maharashtra, India. Contact: Mobile:
+91 9270367704, Email ID – [email protected], [email protected], www.isac.co.in
Safety relays / Safety modules
Model:AWAX26XXL • PL=e Acc. to EN ISO 13849-1
• Cat.4 acc. to EN ISO 13849-1
• SIL 3 acc. to EN62061
• Low consumption inputs
• Control of switches with acotom
Process
• Control of mechanical safety systems (
grip switch, foot switch…)
• Deep switch at the back to choose reset
m mode (Auto/manual)
• Power supply24Vac/dc • 22,5 mm Housing
• Compatible with aluminium profile
• Withdrawable terminals
• 3 Safety lines NO +1 NC 8A/250V
• Embedded Version : AWAX26XXL12V
Model:CO13XXL • PL=e Acc. to EN ISO 13849-1
• Cat.4 acc. to EN ISO 13849-1
• SIL 3 acc. to EN62061
• Control of emergency stop buttons
• Control of mechanical switches
• Control of interlocking systems
• Independent supply inputs to avoid
in- rush current
Control of emergency stop buttons
special for maintenance service
Model: COM3C • PL=e Acc. to EN ISO 13849-1 • Cat.4 acc.
to EN ISO 13849-1
• SIL 3 acc. to EN62061 • IIIC
selon EN 574
• 2 control button 1NO+1NC • 22,5 mm
Housing
• Allowed pushing time difference between
buttons: 400MS
• Sortie 2NO + 1NC 8A/250V
• Test input
• DLC short circuit monitoring
• Withdrawable terminals
• Power supply24Vac/dc
• Type I
Designed for bimanual buttons
Model: C4CK Safety relay.
CAPTIVE KEY MODULE : the key
position overpasses the switch status
Version A
Key locked and turned : 4NO+1NC
8A/250V
Key removed : 4NC+1NO 8A/250V
Version B
Key locked and turned : 4NC+1NO
8A/250V
Key removed : 4NO+1NC 8A/250V
Versions A and B
1 line for test loop and 2 LEDs
Detection of Null speed/zero speed for interlocking system
Model:SPEEDTRONIC N • PL = e selon EN ISO 13849-1
• Cat.4 selon EN ISO 13849-1
• SIL 3 selon EN 62061
• Compatible with frequency variator
• Selectable threshold
• Selectable response time
• Monitor the stills and of a 3 phased motor
• Output compatible with programmable module
• Output 4 lines 8A:250V (3NO+1NC)
• Up to 690V 3 phased motor.
• Adjustable persistence from 2 to 7 S
• No speed sensor
• Adjustable timing from 2 to 7 S for opening interlocking systems
• Neither mechanical accessories nor motor intervention
ISAC ENTERPRISES (Industrial Safety & Automation Components)
Regi. Office: New Sumthana, Triratna Society, Ta: Bhadrawati, Dist. – Chandrapur - 442 902, Maharashtra, India. Contact: Mobile:
+91 9270367704, Email ID – [email protected], [email protected], www.isac.co.in
Safety Switches plastic housing (without locking) Safety switch 90 degree
adjustable head.
Safety Hinge :
Zinc plated steel shaft
Safety switch Fully turnable head
Safety hinge
Zinc plated steel lever
Safety Switches metal housing (without locking) Safety switch 90 degree
adjustable head
Safety Hinge Zinc plated steel shaft
Safety switch Fully turnable head
Safety hinge Zinc plated steel lever
Pull wire / Rope Pull Safety switches Metal housing Pull wire with reset
For emergency start
Pull wire without reset
For simple stop
Pull wire with reset
For emergency start
Pull wire without reset
For simple stop
ISAC ENTERPRISES (Industrial Safety & Automation Components)
Regi. Office: New Sumthana, Triratna Society, Ta: Bhadrawati, Dist. – Chandrapur - 442 902, Maharashtra, India. Contact: Mobile:
+91 9270367704, Email ID – [email protected], [email protected], www.isac.co.in
Safety Hinges with NO/NC contacts Safety Hinge back axial output
Safety Hinge M12,8 pole
connector
Safety Hinge
Bottom axial output
Safety Hinge
Top axial output
Vibration Monitoring products
Vibration sensors:
Our products include general and special purpose accelerometers, velocity sensors, eddy current probes and LVDTs. They are used in a diverse
range of applications, such as; automotive, aerospace, industrial processing, power stations and wind turbines. Also, as an OEM we can design and
develop custom built sensors.
General Purpose Monitoring Sensors:
Monitoring Sensors are for use with PLC’s and other industrial controllers to provide the user with a continuous output of vibration usually as a 4-
20mA signal. Changes in the monitor signal will allow the user to spot vibration changes in the part of the machine to which the sensor is attached.
Rapid changes accompany such conditions as machinery working loose from its mountings, fan blade malfunction, bearing failure all of which
require immediate attention and machine shutdown to avoid widespread damage and loss of machine time. If the signal is logged at regular
intervals, gradually increasing vibration indicates wear in the part of the machine where the sensor is fitted calling for replacement or detailed
study with a portable vibration analyser.
ISAC ENTERPRISES (Industrial Safety & Automation Components)
Regi. Office: New Sumthana, Triratna Society, Ta: Bhadrawati, Dist. – Chandrapur - 442 902, Maharashtra, India. Contact: Mobile:
+91 9270367704, Email ID – [email protected], [email protected], www.isac.co.in
Triaxial Sensors:
A lightweight, compact, side-entry triaxial sensor ideal for the test laboratory or light industrial applications.
Vibration meter:
The MTN/VM220 is a compact, rechargeable, portable handheld Vibration meter designed to conform to ISO10816-3 and operate with a constant
current accelerometer providing accurate vibration measurements. Features comprise of the ability to store up to 100 time-stamped readings,
including; RMS, peak, peak-peak, crest factor and bearing conditions all on an easy to read vibrant colour LCD display.
Submersible General Purpose Sensors:
Submersible, general purpose, top-entry, constant current accelerometer with isolated AC output for use in submersible conditions with integral
heavy duty polyurethane cable.
ATEX and IECEx Group II certified :
ATEX and IECEx Group II certified. General purpose, top-entry, velocity transducer with DC output with integral stainless overbraided cable.
ISAC ENTERPRISES (Industrial Safety & Automation Components)
Regi. Office: New Sumthana, Triratna Society, Ta: Bhadrawati, Dist. – Chandrapur - 442 902, Maharashtra, India. Contact: Mobile:
+91 9270367704, Email ID – [email protected], [email protected], www.isac.co.in
Vibration Switch:
Vibration switches with internal or external vibration sensor, alarm relays and 4-20mA output. A complete condition monitoring and alarm module
operating from 110/230VAC or 24VDC.
Trip Amplifiers :
4002ALM-6 Universal Input Trip Amplifier
ma, volts, thermocouple & rtd inputs
configurable trip actions and failsafe modes
Display of input,setpoints and configuration
Features such as latching, delay on as standard
Isolated Transmitter supply and retransmitted output
The 4002ALM-6 has been designed to perform virtually any Trip Amplifier function 'out of the box’.
With input types including mA, volts, thermocouples and RTD's and others and a re-transmitted 4-20mA or voltage output as standard, the
4002ALM-6 has every feature required built-in as standard. Functions such as latching, delay on, delay off and power on delays can all be called
up from the built-in menus, no PC software or programming is required. The power supply can be anything from 16 to 30Vdc.
2002ALMHL Dual Setpoint Trip Amplifier
Wide range of mA or voltage inputs
Configurable Trip Action- failsafe modes
Isolated Input Stage
Setpoints available as 0-10V on setpoint terminals
24 Vdc or 24Vac supply as standard
The 2002ALMHL accepts a wide range of mA and voltage inputs, including 4-20mA, 0-20mA, 0-10V and 1-5V.the unit has two relay alarm outputs
which can be configured as high or low alarms and both relays have change-over contacts which are mains rated.Each relay can be configured as
fail-safe or non-fail-safe and each LED indiactor can be ON when the units is in alarm or OFF when an alarm state is reached. It is also possible to
use the device as a latching trip amplifier with a single alarm output.
The unit is powered from a range of voltages including 12Vdc 24Vdc and 24Vac.