Document Title: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS Document # 6510030093 REV 02 Where Used: 09507055 Page 1 of 36 Senior Manager, Engineering: Harish Gopalan Manager, Engineering: DCC: RJ Garside Originator: Halappa Begurappa Barun Paul DATE: September 30, 2011 DATE: DATE: DATE: September 30, 2011 6510430198 Rev 00 Original Date Issued: December 13, 2010 Contents 1 About this Document ................................................................................................................. 3 1.1 Hardware .................................................................................................................................... 3 1.1.1 Dell PowerEdge T610 Views ..................................................................................................... 3 2 Creating Quality Server on Dell PowerEdge T610 .................................................................... 4 2.1 Configuring BIOS ...................................................................................................................... 5 2.1.1 Configuring the BIOS settings ................................................................................................... 5 2.2 RAID Configuration ................................................................................................................... 8 2.2.1 Starting the RAID Configuration Program ................................................................................ 8 2.2.2 Deleting RAID configuration ..................................................................................................... 8 2.2.3 1 x RAID 1, 2 Hard Disks .......................................................................................................... 9 2.2.4 2 x RAID1, 4 Hard Disks ......................................................................................................... 11 2.3 Installing Operating System using Experion PKS R400 System Initialization Media ............ 15 2.3.1 Generating the Configuration Files for Target Machine .......................................................... 15 2.3.2 Installing the Operating System on the Target Machine using Experion PKS R400 System Initialization Media .................................................................................................................. 22 2.4 Creating Boot media................................................................................................................. 27 2.5 Display Properties configuration .............................................................................................. 27 2.6 Dell Open Manage ................................................................................................................... 31 2.6.1 Configuring Dell Open Manage6.2 .......................................................................................... 31 2.7 Installing the RAE .................................................................................................................... 34 3 Additional Information ............................................................................................................. 34 3.1 BIOS Update utility.................................................................................................................. 34 3.1.1 Installing the appropriate BIOS on R400.x platform ............................................................... 35

Transcript of PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support...

Page 1: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 1 of 36

Senior Manager, Engineering: Harish Gopalan

Manager, Engineering:

DCC: RJ Garside

Originator: Halappa Begurappa Barun Paul

DATE: September 30, 2011 DATE: DATE: DATE: September 30, 2011 6510430198 Rev 00 Original Date Issued: December 13, 2010

Contents

1 About this Document ................................................................................................................. 3 1.1 Hardware .................................................................................................................................... 3 1.1.1 Dell PowerEdge T610 Views..................................................................................................... 3 2 Creating Quality Server on Dell PowerEdge T610.................................................................... 4 2.1 Configuring BIOS ...................................................................................................................... 5 2.1.1 Configuring the BIOS settings ................................................................................................... 5 2.2 RAID Configuration................................................................................................................... 8 2.2.1 Starting the RAID Configuration Program ................................................................................ 8 2.2.2 Deleting RAID configuration..................................................................................................... 8 2.2.3 1 x RAID 1, 2 Hard Disks .......................................................................................................... 9 2.2.4 2 x RAID1, 4 Hard Disks ......................................................................................................... 11 2.3 Installing Operating System using Experion PKS R400 System Initialization Media ............ 15 2.3.1 Generating the Configuration Files for Target Machine .......................................................... 15 2.3.2 Installing the Operating System on the Target Machine using Experion PKS R400 System

Initialization Media .................................................................................................................. 22 2.4 Creating Boot media................................................................................................................. 27 2.5 Display Properties configuration.............................................................................................. 27 2.6 Dell Open Manage ................................................................................................................... 31 2.6.1 Configuring Dell Open Manage6.2.......................................................................................... 31 2.7 Installing the RAE.................................................................................................................... 34 3 Additional Information............................................................................................................. 34 3.1 BIOS Update utility.................................................................................................................. 34 3.1.1 Installing the appropriate BIOS on R400.x platform ............................................................... 35

Page 2: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 2 of 36

Honeywell Proprietary and Confidential DO NOT COPY

Related documents

6510020334 - Real-Time Application Environment (RAE) R600 for Experion PKS R400.2 Release and Installation Notes

51154481 - Experion PKS System Initialization Media Software Change Notice

46027201 - Ghost Backup for Da Vinci and MXProLine Systems user guide

EP-DSX256 - Fault Tolerant Ethernet Installation and Service Guide

EPDCSX36 – Software Installation Users Guide

EPDCX506 – Supplementary Installation Tasks Guide

Revision history

Rev DCN# Date Author Description of Changes

00 - 13-Dec-2010 Halappa Begurappa

Barun Paul

Vidya Ramarao

New document released.

01 20895 4-Jan-2011 Vidya Ramarao Updated the review comments provided by the DE team.

02 20970 30-Sep-2011 Halappa Begurappa

Barun Paul

Updated the document with Init media R100.3 changes and BIOS update Utility.

Page 3: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 3 of 36

Honeywell Proprietary and Confidential DO NOT COPY

1 About this Document

This document provides instructions on producing Quality Server on Windows 2008 using the Experion PKS System Initialization media (EXPPlus media).

These instructions are applicable to Dell PowerEdge T610 Servers.

1.1 Hardware

For more information about Dell PowerEdge T610 hardware specifications, see section 1.1.1.

1.1.1 Dell PowerEdge T610 Views

Figure 1-1 T610 Back panel view and slot details

Page 4: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 4 of 36

Honeywell Proprietary and Confidential DO NOT COPY

Table 1-1 T610 Back panel view connection description

Sl No. Connection Details Remarks

1 NIC: Two RJ-45 for integrated 10/100/1000 Mbps Ethernet

-

2 Serial connector: 9-pin, DTE, 16550 compatible -

3 USB: Six 4-pin, USB 2.0 compliant -

4 Video: 15-pin VGA -

5 Optional external VFlash card: One optional flash memory card slot with iDRAC6 Enterprise

-

6 Rear system ID button, Rear system status/ID blue/amber LED

-

7 Optional RJ-45 MEA connector -

Table 1-2 T610 Slot Details

Slot No. Slot Type Remarks

Slot 1 PCIe x4 Dual Port NIC (Option)

Slot 2 PCIe x8 -

Slot 3 PCIe x8 -

Slot 4 PCIe x4 -

Slot 5 PCIe x4 -

2 Creating Quality Server on Dell PowerEdge T610

To create a RAE R600 Quality Server on the Dell PowerEdge T610 by using the Experion PKS R400 System Initialization media, you must perform the following tasks.

Task See Section Completed?

Configuring the BIOS settings 2.1.1

RAID Configuration 2.2

Installing Operating System using Experion PKS R400 System Initialization Media 2.3

Creating Boot media 2.4

Display Properties configuration 2.5

Dell Open Manage 2.6

Installing the RAE 2.7

Page 5: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 5 of 36

Honeywell Proprietary and Confidential DO NOT COPY

2.1 Configuring BIOS

2.1.1 Configuring the BIOS settings

ATTENTION: The Dell server comes with BIOS configuration settings based on the Honeywell CFI. However, it is recommended to verify, and reconfigure the same if needed.

CAUTION: The Dell server comes with Custom BIOS installed and it is recommended not to install any other version of the BIOS manually.

To configure the BIOS settings

1. Start the computer.

2. Press F2 to enter the System Setup.

The Dell Inc. (www.dell.com)-PowerEdge T610 dialog box appears.

Figure 2-1 Dell PowerEdge T610 BIOS Version

Refer the subsequent steps to continue with the BIOS Settings.

Figure 2-2 BIOS Settings Details

Page 6: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 6 of 36

Honeywell Proprietary and Confidential DO NOT COPY

2.1.1.1. Verifying the System Time and System Date

1. System Time

2. System Date

Figure 2-3 BIOS Settings - System Time and System Date

2.1.1.2. Boot Sequence Settings

1. Select the Boot Settings using UP/DOWN ARROW key.

2. Press [ENTER].

The Boot Configuration details are displayed.

Figure 2-4 BIOS Settings - Boot Sequence

3. Select Boot Sequence using UP/DOWN ARROW key.

4. Press [ENTER].

5. Under Boot Sequence,

a. Change the boot sequence order by using + / - key.

b. Press Space to enable the following drives.

SATA Optical Drive

Hard Drive C: (Integrate RAID PERC 6/i Integrate)

Figure 2-5 BIOS Settings - Boot Sequence Settings

NOTE: If NIC card is enabled with PXE, then an additional option is listed under Boot Sequence. For example: Embedded NIC1 MBA v5.0.5 Slot 0100.

6. Press [Esc] to exit Boot Sequence.

Page 7: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 7 of 36

Honeywell Proprietary and Confidential DO NOT COPY

7. Press [Esc] again to return to System Setup window.

2.1.1.3. Integrated Devices settings

1. Select Integrated Devices using UP/DOWN ARROW key.

2. Press [ENTER] to view the list of integrated devices.

NOTE: Verify that the status of Embedded NIC1 and NIC2 option is Enabled.

3. Under Embedded NIC1 and NIC2 select Enabled by pressing Space key.

Figure 2-6 BIOS Settings - Integrated Devices Settings

4. Press [Esc] to exit.

2.1.1.4. System Security Settings

1. Select the System Security using UP/DOWN ARROW key.

2. Press [ENTER].

3. Select Setup Password.

4. Press [ENTER].

5. Under Setup Password, type the new password as hmxresult and confirm the same.

Figure 2-7 BIOS Settings – Password Settings

6. Select AC Power Recovery using UP/DOWN ARROW key.

7. Press [ENTER].

8. Under AC Power Recovery, select Last.

Page 8: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 8 of 36

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-8 BIOS Settings – AC Power Recovery Settings

9. Press [Esc].

A message appears and prompting you to save changes and exit the BIOS.

10. Press [ENTER].

The system restarts automatically.

2.2 RAID Configuration

2.2.1 Starting the RAID Configuration Program

After the system restarts, start the RAID Configuration program.

To start the RAID Configuration program

11. After the system restarts, a message appears, prompting you to press <Ctrl+R> to run the Configuration utility.

RAID Configuration utility program starts.

2.2.2 Deleting RAID configuration

Delete the existing RAID Configuration

CAUTION: Deleting the RAID Volume deletes all the data from the Hard Disk.

To delete RAID Configuration

1. Start the RAID Configuration Utility program.

2. Under Virtual Disk Management (VD Mgmt), select Controller 0 by using the UP/DOWN ARROW key.

3. Press F2 to view the options available.

Page 9: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 9 of 36

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-9 RAID Configuration – Delete RAID

4. Select Clear Config by using the UP/DOWN ARROW key.

A message prompting you to confirm to clear the configuration appears.

5. Answer YES to confirm.

Depending on the hard disc present in the Server configuration, refer section 2.2.3 or 2.2.4 to configure RAID.

2.2.3 1 x RAID 1, 2 Hard Disks

If the Server configuration has 2 Hard disk (each 146 GB), perform the following to configure them as one virtual disk of RAID 1.

To setup RAID configuration

1. Start the RAID Configuration Utility program.

2. Under Virtual Disk Management (VD Mgmt), select Controller 0 by using the UP/DOWN ARROW key.

3. Press F2 to view the options available.

Figure 2-10 RAID 1, 2 Hard Disks Configuration

4. Select Create New VD by using the UP/DOWN ARROW key.

5. Press [ENTER].

The Create New VD screen appears.

Page 10: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 10 of 36

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-11 RAID 1, 2 Hard Disks Configuration – Create New VD

6. Press the [TAB] key to select the RAID Level row.

7. Press [ENTER] to view the list of RAID Level available.

8. Select RAID-1 from the list by using the UP/DOWN ARROW key, and then press [ENTER].

9. Press the [TAB] key to go to Physical Disks.

10. Under Physical Disks, select drives 00:00 and, 00:01 by using SPACE key.

11. Press [TAB] key to move to VD Name field under Basic Settings section.

12. Under Basic Settings, type the VD Name as VD0.

13. Press [TAB] key to move to Advanced Settings row and press SPACE key to select it.

14. Press [TAB] key to move to Initialize row and press SPACE key to select it.

15. Press [TAB] key to move to OK and press [ENTER].

NOTE: Initialization deletes all the data in the virtual disk and a message appears, prompting you to confirm to delete the data.

Figure 2-12 RAID 1, 2 Hard Disks Configuration – RAID Level

16. Select OK and press [ENTER] to continue.

Page 11: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 11 of 36

Honeywell Proprietary and Confidential DO NOT COPY

NOTE: Ensure that Virtual Disk capacity is displayed as 100%.

17. Press [Esc] to exit.

A message appears, prompting you to confirm the exit.

18. Select OK and Press [ENTER].

19. Press <Ctrl+Alt+Del> to reboot the system.

After completing RAID configuration go to section 2.3.

2.2.4 2 x RAID1, 4 Hard Disks

If the Server configuration has 4 Hard disc (each 146 GB), perform the following procedure to configure them as two virtual disks of RAID 1.

2.2.4.1 Create and initialize the virtual disk 0

To setup RAID configuration

1. Start the RAID Configuration Utility program.

2. Under Virtual Disk Management (VD Mgmt), select Controller 0 by using the UP/DOWN ARROW key.

3. Press F2 to view the options available.

Figure 2-13 RAID 1, 4 Hard Disks Configuration

4. Select Create New VD by using the UP/DOWN ARROW key.

5. Press [ENTER].

The Create New VD screen appears.

Page 12: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 12 of 36

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-14 RAID 1, 4 Hard Disks Configuration – Create New VD

6. Press the [TAB] key to select the RAID Level row.

7. Press [ENTER] to view the list of RAID Level available.

8. Select RAID-1 from the list by using the UP/DOWN ARROW key, and then press [ENTER].

9. Press the [TAB] key to go to Physical Disks.

10. Under Physical Disks, select drives 00:00 and, 00:01 by using SPACE key.

11. Press [TAB] key to move to VD Name field under Basic Settings section.

12. Under Basic Settings, type the VD Name as VD0.

13. Press [TAB] key to move to Advanced Settings row and press SPACE key to select it.

14. Press [TAB] key to move to Initialize row and press SPACE key to select it.

15. Press [TAB] key to move to OK and press [ENTER].

NOTE: Initialization deletes all the data in the virtual disk and message appears, prompting you to confirm deleting the data.

Page 13: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 13 of 36

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-15 RAID 1, 4 Hard Disks Configuration – Virtual Disk 0

16. Select OK and press [ENTER] to continue.

NOTE: Ensure that Virtual Disk capacity is displayed as 100%.

A message Initialization complete on VD0 appears.

2.2.4.2 Create and initialize the virtual disk 1

To setup RAID configuration

1. Start the RAID Configuration Utility program.

2. Under Virtual Disk Management (VD Mgmt), select Controller 0 by using the UP/DOWN ARROW key.

3. Press F2 to view the options available.

Figure 2-16 RAID 1, 4 Hard Disks Configuration

4. Select Create New VD by using the UP/DOWN ARROW key.

5. Press [ENTER].

Page 14: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 14 of 36

Honeywell Proprietary and Confidential DO NOT COPY

The Create New VD screen appears.

Figure 2-17 RAID 1, 4 Hard Disks Configuration – Create New VD

6. Press the [TAB] key to select the RAID Level row.

7. Press [ENTER] to view the list of RAID Level available.

8. Select RAID-1 from the list by using the UP/DOWN ARROW key, and then press [ENTER].

9. Press the [TAB] key to go to Physical Disks.

10. Under Physical Disks, select drives 00:02 and, 00:03 by using SPACE key.

11. Press [TAB] key to move to VD Name field under Basic Settings section.

12. Under Basic Settings, type the VD Name as VD1.

13. Press [TAB] key to move to Advanced Settings row and press SPACE key to select it.

14. Press [TAB] key to move to Initialize row and press SPACE key to select it.

15. Press [TAB] key to move to OK and press [ENTER].

NOTE: Initialization deletes all the data in the virtual disk and message appears, prompting you to confirm deleting the data.

Figure 2-18 RAID 1, 4 Hard Disks Configuration – Virtual Disk 1

16. Select OK and press [ENTER] to continue.

Page 15: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 15 of 36

Honeywell Proprietary and Confidential DO NOT COPY

NOTE: Ensure that Virtual Disk capacity is displayed as 100%.

17. Press [Esc] to exit.

A message prompting you to confirm the exit appears.

18. Select OK and press [ENTER].

19. Press <Ctrl+Alt+Del> to reboot the system.

2.3 Installing Operating System using Experion PKS R400 System Initialization Media

CAUTION:

Users must use Experion PKS System Initialization R100.x (or Later) media along with HPS Operating System Reinstallation media to install Windows Server 2008 operating system on the Honeywell qualified Dell PowerEdge R710 (MLK) and PowerEdge T610 (MLK) machines.

For detailed information on above media refer to the latest Experion PKS System Initialization Media Software Change Notice (SCN).

2.3.1 Generating the Configuration Files for Target Machine

2.3.1.1 Prerequisites

You need a standalone computer with CD/DVD ROM and Windows OS (Win2003, Win2008 or Win XP or Win 7) to generate the configuration files for the target machine.

The configuration files generated on the standalone computer must be saved in a pen drive or any removable disk as a backup. You need to use this configuration file along with Experion PKS R400 System Initialization media on the target machine.

2.3.1.2 Generating Configuration Files

Perform the following steps on the standalone computer to generate the configuration file for the target machine.

NOTE:

Acknowledge the user account control dialog box, if it appears. It is not necessary or mandatory for the user account control dialog box to appear during the installation process. This information is applicable for the remainder of this manual, unless explicitly stated otherwise.

Page 16: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 16 of 36

Honeywell Proprietary and Confidential DO NOT COPY

1. Insert the Experion PKS R400 System Initialization media into the CD/DVD drive of

standalone computer (not the target computer).

The Honeywell- Experion PKS System Initialization dialog box appears.

Figure 2-19 Honeywell- Experion PKS System Initialization

2. Click Launch Setup.

3. Click Yes, if the User Account Control dialog box appears.

The Initializing Experion PKS System Installer message appears.

The Experion PKS System Initialization Wizard appears.

Page 17: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 17 of 36

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-20 Configuration file Generation selection

4. Select Generate configuration files.

5. Click Next.

NOTE:

If the configuration files are already generated for the target machine, select Modify existing configuration files. Click Browse to browse to the configuration files and select the InitMediaOptions.xml file. Click Next. The subsequent dialog boxes are displayed according to the selections made as per the configuration files. You can modify the selections if required.

The Platform Configuration dialog box appears.

Page 18: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 18 of 36

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-21 Configuration file - Platform Configuration

6. From Choose Configuration, select Reinstall OS and Configure System.

7. Uncheck the Product Installation. You need to uncheck this checkbox as the OS installation needs to be done first.

8. From Select Platform, select Server, and select the Dell Model for the target machine from the drop-down list.

9. From Select Operating System, select Server and Windows Server 2008 Standard from drop-down list.

10. Click Next.

The Operating System Configuration dialog box appears.

Page 19: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 19 of 36

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-22 Configuration file – Operating System Configuration

11. For System Settings:

a. Select the Local Language from the drop-down list.

b. Select the Time Zone from the drop-down list appropriate to the geographical location where the system will be used.

c. Type the Computer Name

Following are the naming conventions that you need to follow, while creating a computer name.

The computer name must be 15 characters or less in length and should begin with an alphabetic character (“a to z” or “A to Z”) and cannot contain spaces or other non-standard characters.

The last letter for Redundant Servers must end in the letter A or B, with the same Base Name. For example, HSERVA and HSERVB.

All other nodes including non-redundant Servers Must Not end with the letters A or B.

d. Type the Company Name

e. Type the Customer Name

NOTE: For the Company Name and Customer Name do not use special characters.

f. Type the Workgroup Name

Page 20: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 20 of 36

Honeywell Proprietary and Confidential DO NOT COPY

12. In the Account and Password, type the following details: a. User Account Name (QCSAdmin)

b. Password (Hmxresult1#) and confirm the password.

13. Uncheck the Microsoft Embedded COA (Certificate Of Authenticity) is not available on this platform check box. By doing this you need not enter the product key.

14. Click Next.

The Network and Input/Output Devices Configuration dialog box appears.

NOTE: For the systems with FTE connections, two integrated Broadcom NIC ports must be enabled in BIOS or You need to install the Intel Pro 1000 PT Dual Port Network adapter.

Figure 2-23 Configuration file – Network and I/O Devices Configuration

15. For configuring the systems with FTE, proceed with Step 17.

16. For configuring the system with Ethernet, select the Network Type as Ethernet, select the No. of Adapters as One from the drop-down list and Network Link Speed as 100 mbps Full Duplex.

17. In the Network Configuration

Select the Network Type as FTE for systems with FTE

Select No. of Adapters as Two for systems with FTE

The configuration of a network port can be changed by selecting and clicking TCP/IP Properties for NIC button.

18. The I/O details are selected by default.

Page 21: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 21 of 36

Honeywell Proprietary and Confidential DO NOT COPY

19. In the FTE Configuration

Type the Multicast Address

Type the Device Index

Type the UDP Source Port

Type UDP Destination Port

Provide a Friendly Name

NOTE: For detailed information about FTE installation and configuration refer to Fault Tolerant Ethernet Installation and Service Guide - FE05-400 (Document ID: EP-DSX256).

20. Click Next.

21. Read through the Confirmation Configuration Summary details, and click Save Config files.

Figure 2-24 Configuration file – Network and I/O Devices Configuration

To save the configuration files, browse through one of the following options.

a. You can either use USB flash drive, or local hard disk to save the configuration files to be used on this computer for future use. OR

b. Save the generated configuration files in a separate folder at the root of the C drive, floppy drive, or USB drive.

22. Click OK.

The Experion PKS System Initialization dialog box appears indicating that Configuration files are saved successfully.

Page 22: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 22 of 36

Honeywell Proprietary and Confidential DO NOT COPY

23. Click OK.

24. Click Finish.

25. Read the instructions on the Honeywell Experion PKS System Initialization R100.3 - DialogManager

Figure 2-25 Configuration file – EPKS System Init Media Booting Instructions

26. Click OK.

27. Close the Honeywell- Experion PKS System Initialization window.

2.3.2 Installing the Operating System on the Target Machine using Experion PKS R400 System Initialization Media

1. In the target machine, insert Experion PKS R400 System Initialization media, connect the USB flash drive that has the configuration file created for the target machine in section 2.3.1.2 and re-start the computer.

Page 23: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 23 of 36

Honeywell Proprietary and Confidential DO NOT COPY

NOTE: Ensure that the USB drive containing the configuration files generated for the target machine is connected before you re-start the computer to avoid any removable disc detection.

2. Watch the monitor while it restarts and press any key when you see the message Press any key to boot from CD or DVD.

The Windows is loading files message appears.

The Experion PKS System Initialization Pre-Install Utility Window appears.

Figure 2-26 Browsing for Configuration Files

3. Click Browse. Browse to the path where the configuration file is present.

4. Select InitMediaOptions.xml files.

5. Click Open.

6. Click Next.

The Experion PKS System Initialization Pre-Install Utility dialog box appears.

Page 24: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 24 of 36

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-27 System Hard Disk partition details

7. In the Configuration details, select the following:

Partitions count as Two from the drop-down list.

Type the size of Primary partition as 70.

8. Select DVD as the appropriate location for installation media.

9. Click Next.

Notice of Licensed Software dialog box appears.

Page 25: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 25 of 36

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-28 Honeywell End User License Agreement

10. Read the license agreement and select I accept the terms in the license agreement.

11. Click Install.

A warning message appears indicating that the disk contents and partition will be deleted.

12. Click Yes to continue.

13. The Experion PKS System initialization preparing for Operating System installation dialog box appears.

A message appears prompting to insert the Windows 2008 Reinstallation DVD.

Page 26: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 26 of 36

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-29 Windows 2008 Reinstallation DVD insertion

14. Remove the Experion PKS System Initialization media and insert the HPS operating system reinstallation media for Windows server 2008.

15. Click OK.

The Installing Windows…dialog box displays the status of the Operating System installation.

16. During the Operating System installation, your computer restarts several times.

17. After the Operating System installation is completed, a message appears prompting you to insert the Experion PKS System Initialization R100.3 DVD.

Figure 2-30 EPKS Init Media R100.3 DVD insertion

18. Remove the Windows 2008 Reinstallation DVD and insert the Experion PKS System Initialization R100.3 DVD. Click OK.

The Initializing Experion PKS System Installer... message appears.

19. After the initial personalized settings are completed, the Experion PKS-Status Display dialog box appears, displaying the status of the Operating System Configuration.

A message appears in the Experion PKS-Status Display dialog box confirming the Experion PKS System Initialization Installation is completed successfully.

20. Click OK to restart the system.

21. After the system restarts, login to the machine as QCSAdmin and verify the OS installation.

Page 27: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 27 of 36

Honeywell Proprietary and Confidential DO NOT COPY

2.4 Creating Boot media

Windows PE Boot media is needed to run the Norton ghost application on this RAE node for creating its Ghost image (GHO file). You can use the same media to restore Ghost Images that are taken already.

NOTE: Use the computer which is installed with Windows Operating System and the CD/DVD Burning Software for creating the Boot Media.

NOTE: Refer the Ghost Backup for Da Vinci and MXProLine Systems user guide (46027201) for more details on using Norton Ghost on RAE node.

Use the burning software to burn a Boot Media CD from the Production DVD_124\OSDeployment\01000936_REVC_winpe.iso image.

2.5 Display Properties configuration

To configure the display properties

1. Right-click on the desktop, and then click Personalize from the shortcut menu.

The Personalization dialog box appears.

Page 28: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 28 of 36

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-31 Personalization Dialog box showing Display configuration settings

2. Select Display Settings under Personalize appearance and sounds.

The Display Settings dialog box appears.

Page 29: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 29 of 36

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-32 Display Settings Dialog box

3. Under Resolution, move the Slider to set a screen resolution of 1280x1024.

4. Under Colors, select Medium (16-bit).

5. Click Advanced settings.

The Generic PnP Monitor and Matrox G200eW (Nuvoton) dialog box appears.

Page 30: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 30 of 36

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-33 Generic PnP Monitor and Matrox G200eW (Nuvoton)

6. Click the Monitor tab.

7. Under Monitor settings, set the Screen refresh rate based on type of monitor you are using, as follows:

For LCD Monitors – 60 Hertz.

For non-LCD Monitors – 75 Hertz

8. Click Apply.

The Display Settings message appears, prompting you to keep the display settings you have configured.

9. Click Yes.

10. Click OK to save the monitor settings and close the dialog box.

11. Click OK to close the Display Settings dialog box.

12. Close the Personalization dialog box.

Page 31: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 31 of 36

Honeywell Proprietary and Confidential DO NOT COPY

2.6 Dell Open Manage

The Dell Open Manage6.2 is installed through Experion PKS R400 System Initialization media and the Server Administrator icon is created on the desktop.

2.6.1 Configuring Dell Open Manage6.2

To configure the Dell Open Manage6.2

1. Double-click the Server Administrator icon on the desktop.

NOTE: Use the Administrator password to log on to Dell Open Manage Server Administrator.

The website‘s security certificate webpage appears.

2. Click Continue to this website (not recommended) link.

The Security Alert dialog box appears and prompting you to for the confirmation.

3. Click OK.

Page 32: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 32 of 36

Honeywell Proprietary and Confidential DO NOT COPY

NOTE: If the Dell Open Manage fails to open, perform the following steps to open the Dell Open Manage.

If the Server is not connected to the Internet, then Internet Connection Wizard dialog box appears prompting you to setup the internet connection.

Figure 2-34 Internet Connection Wizard

4. Click the View the ISP offer provided by my computer manufacturer.

5. Click OK.

6. Close the Internet Signup window.

The Security Alert dialog box appears.

Figure 2-35 Security Alert

Page 33: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 33 of 36

Honeywell Proprietary and Confidential DO NOT COPY

7. Click Yes.

The Internet Explorer dialog box appears.

Figure 2-36 Internet Explorer

8. Click Add.

The Trusted sites dialog box appears.

Figure 2-37 Trusted Sites

9. Click Add to add the Server to trusted Web sites list.

The Server address is displayed under Web sites list.

10. Click Close.

The Microsoft Phishing Filter dialog box appears.

Page 34: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 34 of 36

Honeywell Proprietary and Confidential DO NOT COPY

Figure 2-38 Microsoft Phishing Filter

11. Click the Turn off automatic Phishing Filter

12. Click OK.

The Dell Open Manage login webpage appears.

13. Logon with the Administrator User Name and Password.

14. Click OK.

Check that Open Manage has no errors and close application.

2.7 Installing the RAE

For installing RAE R600 on the Server, refer to Real-Time Application Environment (RAE) R600 for Experion PKS R400.2 Release and Installation Notes p/n 6510020334.

3 Additional Information

This section provides additional information related to Operating System loading after major hardware recovery such as Mother Board failure.

3.1 BIOS Update utility

The BIOS Update utility selects Dell’s or Honeywell’s custom BIOS to support/protect operating system activation. Honeywell’s custom BIOS files are derived from generic Dell BIOS files and are mandatory to complete automatic activation of the operating system for platforms that are installed using Honeywell OEM embedded operating systems.

Page 35: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 35 of 36

Honeywell Proprietary and Confidential DO NOT COPY

ATTENTION:

The BIOS Update utility updates the BIOS either to a new version or to any of the previous versions. This is a new feature introduced in Experion PKS System Initialization R100.3 onwards.

CAUTION: You are recommended to use the BIOS Update utility only in case of motherboard failure or motherboard replacement.

The following table lists the platform names and the model numbers with which the BIOS Update utility must be used.

Platform Part Number

T610 6543100028

6543100026

6543100027

In case of motherboard failure, below steps needs to be carried out in order to bring back the server to operation:

1. Replace the motherboard.

2. Complete the motherboard installation.

3. Switch on the platform.

4. Run the BIOS Update utility by referring Section 3.1.1 Installing the appropriate BIOS on R400.x platform.

3.1.1 Installing the appropriate BIOS on R400.x platform

CAUTION: Before starting the BIOS Update utility installation, save all data and close all windows. After the installation platform needs a restart.

Perform the following steps to run the BIOS Update utility on R400.x platforms.

1. Log on to the platform with administrator privileges.

2. Insert Experion PKS System Initialization R100.3 (or Later) media into DVD drive.

3. Browse to <root>\webpage\autorun.htm path.

4. Double-click autorun.htm

The Experion PKS System Initialization On-media documentation dialog box is displayed.

5. In the left pane, click BIOS.

Page 36: PRODUCTION OF QUALITY SERVER ON WINDOWS 2008 USING …balibago.org/Files/RAE/RAE Install Support Docs/6510030093.pdf · New document released. 01 20895 4-Jan-2011 Vidya Ramarao Updated

Document Title: PRODUCTION OF

QUALITY SERVER ON WINDOWS 2008 USING EXPPLUS

Document # 6510030093

REV 02

Where Used: 09507055 Page 36 of 36

Honeywell Proprietary and Confidential DO NOT COPY

The BIOS Minimum Requirements screen is displayed in the right pane.

6. In the right pane, click platformname.exe from the BIOS upgrade application column.

For example, if you are upgrading BIOS version for the R710 platform, click R710.exe file.

7. Save the platformname.exe to your local folder.

8. Browse to the folder containing the installer and double-click WinZipSelfExtractor-<platform name.exe>

9. Click Allow and click Setup.

The BIOS Update dialog box is displayed that contains information about the installed BIOS version and the latest custom BIOS version.

ATTENTION:

The installed BIOS version and the package version displayed in the BIOS Update dialog box varies depending on the server or workstation on which you are performing the installation.

10. Click Yes to continue with the BIOS update installation.

11. Click OK to restart the platform after completing the installation.

CAUTION: Do not click Cancel on the WinZip Self Extractor-<platform name.exe> dialog box or close the WinZip Self Extractor-<platform name.exe> dialog box during installation.

The BIOS update occurs immediately after the platform is restarted.

Information about the BIOS modification is displayed on the screen.

Subsequently, the installed BIOS version is displayed in the Power On Self Test (POST) screen. You can also check the BIOS version by pressing F2 once the POST screen closes.