PRODUCT SELECTION GUIDE Ultraviolet Oxidation (UV) Water Systems Description Applications Flow Rate Unique Features Water Quality Page Ultraviolet Oxidation •Gas chromatography (GC) •Pressurized feed •The same unique features of the base •Type 1 reagent grade water 173 water with less than •Gas chromatography/mass (30psig/min) 2.0 L/min. unit plus: •Resistivity up to 18.3 1 ppb TOC ideal for your spectrometry (GC/MS) •Gravity feed 1.5 L/min •Dual wavelength (185 & 245 nm) megohm-cm most stringent organic •High performance liquid ultraviolet lamp oxidizes organics •TOC less than 1 ppb determinations. chromatography (HPLC) and controls bacterial growth. •Bacteria less than 1 CFU/ml •Ion Chromatography •UV lamp change indicator •Total organic carbon (TOC) •Superior system design Ultraviolet Oxidation •Gas chromatography (GC) •Pressurized feed •Dual wavelength (185 and •Type 1 reagent grade water 182 Produces water meeting •Gas chromatography/mass (30psig/min) 1.5 L/min. 254 nm) ultraviolet light oxidizes •Resistivity up to 18.3 the stringent spectrometry (GC/MS) •Gravity feed 500 ml/min organics and controls bacterial megohm-cm requirements of your •High performance liquid growth. •TOC less than 2 ppb most critical organic chromatography (HPLC) •Bacteria less than 1CFU/ml determinant analysis •ICP and ICP/MS Ideal for usages of •Ion Chromatography < 15 L/Day. •Total organic carbon (TOC) Reservoir Feed Portable Water System Description Applications Flow Rate Unique Features Water Quality Page Reservoir Feed •High performance liquid •0.5 L/min •No plumbing required •Type 1 reagent grade water 179 Ideal for areas where chromatography (HPLC) •Built-in 6.5 liter feed reservoir •Resistivity up to 18.3 plumbing is not •Atomic absorption (AA) megohm-cm available •Total organic carbon (TOC) •TOC less than 5 ppb Ideal for usages of •Gas chromatography/mass < 15 L/Day spectrometry (GC/MS) • ICP and ICP/MS Basic Reagent Grade Water Systems Description Applications Flow Rate Unique Features Water Quality Page Base unit. •Atomic absorption (AA) •Pressurized feed •Field upgradable with addition •Type 1 reagent grade water 172 Ideal for your •ICP and ICP/MS (30 psig/min) 1.8 L/min. of modules. •Resistivity up to 18.3 analytical needs •Ion Chromatography •Gravity feed 1.5 L/min •Complete with remote dispenser. megohm-cm •Gas Chromatography/mass •Digital reading of resistivity, •TOC less than 4 ppb spectrometry (GC/MS) conductivity and total dissolved solids •Bacteria less than 1 CFU/ml •High performance liquid •Optional N.I.S.T. calibration module chromatography (HPLC) •Large capacity individual cartridges Low cost •Atomic absorption (AA) •Pressurized feed •Inexpensive design •Type 1 reagent grade water 185 reagent grade •ICP and ICP/MS (30 psig/min) 2.0 L/min. •Recirculation pump •Resistivity up to 18.3 megohm-cm water •Ion Chromatography •Gravity feed 1.5 L/min •Digital resistivity meter •TOC less than 5 ppb Line Feed •Atomic absorption (AA) •Pressurized feed •50% more ion exchange capacity •Type 1 reagent water 180 Perfect for low volume •ICP and ICP/MS (30psig/min) 1.5 L/min. than EASYpure RF unit •Resistivity up to 18.3 megohm-cm requirements utilizing •Ion Chromatography •Gravity feed 500 ml/min •Permanent water connection •TOC less than 10 ppb direct plumbing. ideal for analytical procedures EASYpure ® UV NANOpure ® Infinity UV EASYpure ® RF NANOpure ® Infinity E-pure EASYpure ® LF EASYpure NANOpure Infinity 164

Transcript of PRODUCT SELECTION GUIDE - Cole-Parmer · PRODUCT SELECTION GUIDE Barnstead I Thermolyne 165...

Page 1: PRODUCT SELECTION GUIDE - Cole-Parmer · PRODUCT SELECTION GUIDE Barnstead I Thermolyne 165 800-553-0039 Ultraviolet Oxidation/Ultrafiltration (UV/UF) Water Systems Description Applications

P R O D U C T S E L E C T I O N G U I D E

U l t r a v i o l e t O x i d a t i o n ( U V ) W a t e r S y s t e m s

Description Applications Flow Rate Unique Features Water Quality Page

Ultraviolet Oxidation •Gas chromatography (GC) •Pressurized feed •The same unique features of the base •Type 1 reagent grade water 173water with less than •Gas chromatography/mass (30psig/min) 2.0 L/min. unit plus: •Resistivity up to 18.31 ppb TOC ideal for your spectrometry (GC/MS) •Gravity feed 1.5 L/min •Dual wavelength (185 & 245 nm) megohm-cmmost stringent organic •High performance liquid ultraviolet lamp oxidizes organics •TOC less than 1 ppbdeterminations. chromatography (HPLC) and controls bacterial growth. •Bacteria less than 1 CFU/ml

•Ion Chromatography •UV lamp change indicator•Total organic carbon (TOC) •Superior system design

Ultraviolet Oxidation •Gas chromatography (GC) •Pressurized feed •Dual wavelength (185 and •Type 1 reagent grade water 182Produces water meeting •Gas chromatography/mass (30psig/min) 1.5 L/min. 254 nm) ultraviolet light oxidizes •Resistivity up to 18.3the stringent spectrometry (GC/MS) •Gravity feed 500 ml/min organics and controls bacterial megohm-cmrequirements of your •High performance liquid growth. •TOC less than 2 ppbmost critical organic chromatography (HPLC) •Bacteria less than 1CFU/ml determinant analysis •ICP and ICP/MSIdeal for usages of •Ion Chromatography< 15 L/Day. •Total organic carbon (TOC)

R e s e r v o i r F e e d P o r t a b l e W a t e r S y s t e m

Description Applications Flow Rate Unique Features Water Quality Page

Reservoir Feed •High performance liquid •0.5 L/min •No plumbing required •Type 1 reagent grade water 179Ideal for areas where chromatography (HPLC) •Built-in 6.5 liter feed reservoir •Resistivity up to 18.3plumbing is not •Atomic absorption (AA) megohm-cmavailable •Total organic carbon (TOC) •TOC less than 5 ppbIdeal for usages of •Gas chromatography/mass< 15 L/Day spectrometry (GC/MS)

• ICP and ICP/MS

B a s i c R e a g e n t G r a d e W a t e r S y s t e m s

Description Applications Flow Rate Unique Features Water Quality Page

Base unit. •Atomic absorption (AA) •Pressurized feed •Field upgradable with addition •Type 1 reagent grade water 172Ideal for your •ICP and ICP/MS (30 psig/min) 1.8 L/min. of modules. •Resistivity up to 18.3analytical needs •Ion Chromatography •Gravity feed 1.5 L/min •Complete with remote dispenser. megohm-cm

•Gas Chromatography/mass •Digital reading of resistivity, •TOC less than 4 ppbspectrometry (GC/MS) conductivity and total dissolved solids •Bacteria less than 1 CFU/ml

•High performance liquid •Optional N.I.S.T. calibration modulechromatography (HPLC) •Large capacity individual cartridges

Low cost •Atomic absorption (AA) •Pressurized feed •Inexpensive design •Type 1 reagent grade water 185reagent grade •ICP and ICP/MS (30 psig/min) 2.0 L/min. •Recirculation pump •Resistivity up to 18.3 megohm-cmwater •Ion Chromatography •Gravity feed 1.5 L/min •Digital resistivity meter •TOC less than 5 ppb

Line Feed •Atomic absorption (AA) •Pressurized feed •50% more ion exchange capacity •Type 1 reagent water 180Perfect for low volume •ICP and ICP/MS (30psig/min) 1.5 L/min. than EASYpure RF unit •Resistivity up to 18.3 megohm-cmrequirements utilizing •Ion Chromatography •Gravity feed 500 ml/min •Permanent water connection •TOC less than 10 ppb

direct plumbing. ideal for analytical procedures

EASYpure ®UV

NANOpure ®Infinity

UV

EASYpure ® RF

NANOpure ®Infinity

E-pure

EASYpure ®LF

EASYpure NANOpure Infinity

164 800-553-0039Barnstead I Thermolyne

CATALOG3NEW 3/17/98 2:17 PM Page 164

Page 2: PRODUCT SELECTION GUIDE - Cole-Parmer · PRODUCT SELECTION GUIDE Barnstead I Thermolyne 165 800-553-0039 Ultraviolet Oxidation/Ultrafiltration (UV/UF) Water Systems Description Applications

P R O D U C T S E L E C T I O N G U I D E

165 800-553-0039Barnstead I Thermolyne

U l t r a v i o l e t O x i d a t i o n / U l t r a f i l t r a t i o n ( U V / U F ) W a t e r S y s t e m s

Description Applications Flow Rate Unique Features Water Quality Page

Ultraviolet Oxidation •Ion free water - AA, ICP •Pressurized feed The same unique features of the •Type 1 reagent grade water 175and ultrafiltration in a ICP/MS (30 psig min) 2.0 L/min base unit plus: •Resistivity up to 18.3 megohm-cmsingle unit. The only •Pyrogen free water, tissue •Gravity feed 1.5 L/min •Automatic intermittent flush •TOC less than 2 ppbvalidated RNase, DNase culture and cell culture •10,000 mw ultrafilter and dual •Pyrogen level less than and DNA free water system. •Organic free water, HPLC wavelength UV lamp (185 and 0.001 EU/ml

and GC/MS 254 nm) •RNase, DNase & DNA free•DNA Amplification •Bacteria less than 1 CFU/ml

Ultraviolet Oxidation •Ion free water - AA, ICP, •Pressurized feed •10,000 molecular weight ultrafilter •Resistivity up to 18.3 183plus Ultrafiltration ICP/MS (30 psig min) 1.3 L/min •Dual wavelength (185 and 254 nm) megohm-cmPerfect for virtually all •Pyrogen free water, tissue •Gravity feed 500 ml/min ultraviolet lamp •TOC levels less than 3 ppbpure water requirements culture and cell culture •Pyrogen levels less thanalong with the UV/UF •Organic free water HPLC 0.005 EU/mlInfinity, the only validated and GC/MS •Bacteria less than 1 CFU/mlNuclease free water system. •DNA Amplification •RNase A and RNase T1 of

various concentrations

M o d e r a t e l y P u r e , S i n g l e a n d D o u b l e C a r t r i d g e S y s t e m s a n d H o l d e r s

Description Applications Flow Rate Unique Features Water Quality Page

When you need •Moderate quality for •Dependent on feed water •Simple design, low cost source of •0.05 to 10 megohm-cm 186moderately pure water general lab use pressure and quality purified water depending on cartridge type

between 0.5 and and configuration2.0 L/min

U l t r a f i l t r a t i o n ( U F ) W a t e r S y s t e m s

Description Applications Flow Rate Unique Features Water Quality Page

Ultrafiltration produces •Cell and tissue culture •Pressurized feed The same unique features as •Type 1 reagent grade water 174water with <0.001 •In Vitro fertilization (30 psig min) 1.8 L/min the base unit plus: •Resistivity up to 18.3EU/ml pyrogens •DNA studies •Gravity feed 1.5 L/min •Automatic intermittent flush megohm-cmIdeal for Life •Monoclonal antibody •Standard 10,000 mw ultrafilter •TOC less than 10 ppbScience needs. production •Optional 5,000 mw ultrafilter •Pyrogen level less than

0.001 EU/ml•Bacteria less than 1 CFU/ml

Ultrafiltration •Cell and tissue culture •Pressurized feed •10,000 molecular weight ultrafilter •Type 1 reagent grade water 181The ideal system for •In Vitro fertilization (30 psig min) 1.3 L/min •Resistivity up to 18.3your low volume •DNA studies •Gravity feed 500 ml/min megohm-cmbiological •Monoclonal antibody •TOC less than 10 ppbrequirements including production •Pyrogen level less than 0.005

cell and tissue culture. EU/ml•Bacteria less than 1 CFU/ml

EASYpure ®UV/UF

NANOpure ®InfinityUV/UF

NANOpure ®Infinity

UF

EASYpure ®UF

B-pure,Bantam,

Hose Nipple

E-Pure B-Pure Single

CATALOG3NEW 3/17/98 2:17 PM Page 165

Page 3: PRODUCT SELECTION GUIDE - Cole-Parmer · PRODUCT SELECTION GUIDE Barnstead I Thermolyne 165 800-553-0039 Ultraviolet Oxidation/Ultrafiltration (UV/UF) Water Systems Description Applications

172 800-553-0039Barnstead I Thermolyne

Cartridge Kits (sold separately)Model # Descriptions Capacity Price

D50256 Type 1 Cartridge Kit Tap/DI Feed 2037 Grains 1 ea. D50251, 3 ea. D50253, 2 ea. FL703X2 as NaCl

D50257 Type 1Cartridge Kit R/O or Dist. Feed 2037 Grains1 ea. D50250, 3 D50253, 2 ea. FL703X2 as NaCl

D50254 ORGANICfree Cartridge Kit Tap/DI Feed 1686 Grains 1 ea. D50251, 2 ea. D50253, 1 ea. D50252, as NaCl2 ea. FL703X2

D50255 ORGANICfree Cartridge Kit R/O or Dist. 1686 Grains Feed. 1 ea. D50250, 2 ea. D50253, 1 ea. as NaClD50252, 2 ea. FL703X2

D50258 Sanitization Cartridge

U.S. Patent Issued: 5,397,468; 5,399,263

NANOpure Infinity Base SystemElectrical

Model # Description Volts Amps Price

D8961 Base 120 3

D8962-33 Base 230 2

-33 Models CE Marked

General SpecificationsOverall Dimensions Maximum Inlet Ship

W x H x D Pressure Weight TemperatureInches (cm) psig Lbs (kg) ºF (ºC)

W H D

20 (51) 24 (61) 16 (41) 100 psig 80 lbs (36.3) 40-120ºF(4-49ºC)

Product flow rates up to 1.8 L/min dependent upon feed water pressure and installed modules.

N A N O P U R E ® I N F I N I T Y B A S E S Y S T E M

D e i o n i z a t i o n

B E N E F I T S

• Produces up to 1.8 LPM ofwater with resistivities of up to18.3 megohm-cm, and T.O.C.values of < 4 ppb. See theindependent test results, pages21-22.

• This system provides yousuperior analytical qualitywater at a lower cost per literthan competitive models.

• Can be easily upgraded at yourfacility to incorporate the UV,UF or UV/UF modules neededfor future pure waterrequirements.

• The NANOpure Infinity can bewall mounted or benchmounted without the additionof any special brackets.

• All models come complete witha remote dispenser allowingyou to deliver up to 1.8 LPM ofwater up to 8 feet (2.4 meters)away from the unit.

• Microprocessor controlledpurity monitor and controls forsimple and accurate operation.

• An easy to read L.C.D. displayprovides you a digitalindication of resistivity,conductivity or T.D.S. (totaldissolved solids).

•A user programmable setpointwill alert you when it is timefor you to change cartridges ata purity level you choose.

• Start/Stop and Standby modesof operation. In standby theunit recirculates water withinthe system for 10 minutesevery hour during periods ofinactivity assuring you water ofthe desired purity when youneed it, without wastingvaluable time or water waitingfor the system to rinse up.

• Calibration verification of the

electronics are accomplishedautomatically on start-up or canbe verified as you require. Anoptional N.I.S.T. traceablemodule can be used to verifycalibration traceable to N.I.S.T.standards.

• An optional purity sensingelectrode can be easily added tothe unit providing you anindication of the resistivity,conductivity or T.D.S. (totaldissolved solids) of the feedwater entering the NANOpureInfinity.

• Four individual easy to installpurifying cartridges provideincreased flexibility inchoosing the proper purifyingmedia for your specializedapplications.

• Integral pressure regulatingvalve provides you the abilityto utilize feed water withpressures up to 100 psigwithout additional equipment.

• All water pathways are virginpolypropylene. Fluro polymersor equally inert materialensuring maintenance of purewater within the system.

Water purification needs change over time. You probably don’t know what type of pure water will be needed in your laboratory in the future.

Now, the New NANOpure Infinity Ultrapure water systems allow you to purchase a water system for your needs today and upgrade the same

unit to suit your needs tomorrow. The all-new NANOpure Infinity reagent grade water system is guaranteed to meet your water purification

needs today and tomorrow.

Remote dispenser allows you todeliver water up to 2.4 metersaway from the unit.

new

2 Year WarrantyCan also grow with yourneeds to a specializedunit

Applications: AA,ICP, ICP/MS,

IC and HPLC

NANOpure Infinity Base System

CATALOG3NEW 3/17/98 2:17 PM Page 172

Page 4: PRODUCT SELECTION GUIDE - Cole-Parmer · PRODUCT SELECTION GUIDE Barnstead I Thermolyne 165 800-553-0039 Ultraviolet Oxidation/Ultrafiltration (UV/UF) Water Systems Description Applications

NANOpure Infinity UV SystemElectrical

Model # Description Volts Amps Price

D8971 UV 120 3

D8972-33 UV 230 2

-33 Models CE Marked

General SpecificationsOverall Dimensions Maximum Inlet

W x H x D Pressure Weight TemperatureInches (cm) psig Lbs (kg) ºF (ºC)

W H D

20 (51) 24 (61) 16 (41) 100 psig 80 (36.3) 40-120ºF(4-49ºC)

Product flow rates up to 1.8 L/min dependent upon feed water pressure and installed modules.

Cartridge Kits (sold separately) & AccessoriesModel # Descriptions Capacity Price

D50256 Type 1 Cartridge Kit Tap/DI Feed 2037 Grains 1 ea. D50251, 3 ea. D50253, 2 ea. FL703X2 as NaCl

D50257 Type 1Cartridge Kit R/O or Dist. Feed 2037 Grains1 ea. D50250, 3 D50253, 2 ea. FL703X2 as NaCl

D50254 ORGANICfree Cartridge Kit Tap/DI Feed 1686 Grains 1 ea. D50251, 2 ea. D50253, 1 ea. D50252, as NaCl2 ea. FL703X2

D50255 ORGANICfree Cartridge Kit R/O or Dist. 1686 Grains Feed. 1 ea. D50250, 2 ea. D50253, 1 ea. as NaClD50252, 2 ea. FL703X2

D50258 Sanitization Cartridge N/A

LMX13 UV Lamp Replacement N/A

U.S. Patent Issued: 5,397,468; 5,399,263

N A N O P U R E ® I N F I N I T Y U V ( U L T R A V I O L E T )

D e i o n i z a t i o n

B E N E F I T S

Includes all of the benefits of aNANOpure Infinity basesystem plus the followingadded benefits:

• Produces up to 1.8 LPM ofwater with less than 1 ppborganics and resistivities up to18.3 megohm-cm.

• Ideal for your most criticalorganic determinant analysisincluding low wavelengthHPLC, gas chromatography,GC/MS, IC (IonChromatography) and TOC(Total Organic Carbon)analysis.

• The dual wavelength UV lampmaintains a bacterial freeenvironment within the systemwhile lowering the TOC.

• Infinity UV can be upgradedin your lab with a UF moduleto make a UV/UF Infinity forRNase and DNA freeapplications.

• The unique design of theNANOpure Infinity UVassures that the system

The NANOpure Infinity UV system provides you water that is not only free of ionic contamination but organics as well. The ultraviolet light

emits both a 254 nm and 185 nm wavelength light source that work together to oxidize organic molecules. The patented ORGANICfree

cartridge ensures that the water quality, with less than 1 ppb organics and resistivities up to 18.3 megohm-cm, is produced and maintained.

produces water with < 1 ppbTOC at a lower cost per literthan competitive models.

• Maximum contact timebetween the water and the UVlamp and cartridges ensuresthat low organic water ismaintained as you aredispensing.

• The UV lamp is energizedperiodically in standbymaintaining both the ionicand organic purity within thesystem during periods ofinactivity.

• System automatically remindsyou when it’s time to changethe UV lamp.

• Two year warranty.

A P P L I C A T I O N S• Gas chromatography (GC)

• Gas chromatography/massspectrometry (GC/MS)

• High performance liquidchromatography (HPLC)

• Ion chromatography (IC)

• Total organic carbon (TOC)

new

T.O.C. < 1 ppbflat HPLCbaselines…TheInfinity UVhas set a newstandard

NANOpure Infinity UV

173 800-553-0039Barnstead I Thermolyne

CATALOG3NEW 3/17/98 2:17 PM Page 173

Page 5: PRODUCT SELECTION GUIDE - Cole-Parmer · PRODUCT SELECTION GUIDE Barnstead I Thermolyne 165 800-553-0039 Ultraviolet Oxidation/Ultrafiltration (UV/UF) Water Systems Description Applications

174 800-553-0039Barnstead I Thermolyne

General SpecificationsOverall Dimensions Max. Inlet

W x H x D Pressure Weight TemperatureInches (cm) psig Lbs (kg) ºF (ºC)

W H D

20 (51) 24 (61) 16 (41) 100 psig 80 (36.3) 40-120ºF(4-49ºC)

Product flow rates up to 1.8 L/min dependent upon feed water pressure and installed modules.

NANOpure Infinity UF SystemElectrical

Model # Description Volts Amps Price

D8981 UF 120 3

D8982-33 UF 230 2

-33 Models CE Marked

Cartridge Kits (sold separately)Model # Descriptions Capacity Price

D50256 Type 1 Cartridge Kit Tap/DI Feed 2037 Grains 1 ea. D50251, 3 ea. D50253, 2 ea. FL703X2 as NaCl

D50257 Type 1 Cartridge Kit R/O or Dist. Feed 2037 Grains1 ea. D50250, 3 D50253, 2 ea. FL703X2 as NaCl

D50254 ORGANICfree Cartridge Kit Tap/DI Feed 1686 Grains 1 ea. D50251, 2 ea. D50253, 1 ea. D50252, as NaCl2 ea. FL703X2

D50255 ORGANICfree Cartridge Kit R/O or Dist. 1686 Grains Feed. 1 ea. D50250, 2 ea. D50253, 1 ea. as NaClD50252, 2 ea. FL703X2

D50258 Sanitization Cartridge N/A

FL898X1 Ultrafilter 5000 mw N/A

FL550X1 Ultrafilter Replacement, 10,000 mw N/A

U.S. Patent Issued: 5,397,468; 5,399,263

N A N O P U R E ® I N F I N I T Y U F ( U L T R A F I L T R A T I O N )

D e i o n i z a t i o n

B E N E F I T S

Includes all of the benefits of aNANOpure Infinity base unitplus the following addedbenefits:

• Produces up to 1.8 LPM ofpyrogen free water (<0.001Eu/ml) with resistivities up to18.3 megohm-cm and TOCvalues < 10 ppb.

• Automatic intermittentultrafilter and manual flushensures that impurities do notdeposit on the surface of theultrafilter.

• Automatic & manual flushmodes provide consistenteffective cleaning of theultrafilter membrane.

• Extended (5 minute) fast flushquickly rinses up theNANOpure Infinity tomaximum purity.

• Optional 5,000 mw ultrafiltercan be used in place of the10,000 mw cutoff weightultrafilter included with theunit.

• Produces superior biologicallypure water at a lower cost perliter than competitive models.

• Two year warranty.

A P P L I C A T I O N S• Cell and tissue culture

• In Vitro fertilization

• DNA studies

• Monoclonal antibody

production

new

NANOpure Infinity UF

If your application requires pyrogen free water, the NANOpure Infinity UF System is for you! This system utilizes a 10,000 mw (optional

5000 mw available) ultrafilter for up to a 6 log reduction in pyrogens and levels < 0.001 Eu/ml. And tomorrow, when your needs change,

simply add a UV module for water virtually free of all contamination.

Produces up to1.8 LPM ofpyrogen free .

2 year warranty

CATALOG3NEW 3/17/98 2:17 PM Page 174

Page 6: PRODUCT SELECTION GUIDE - Cole-Parmer · PRODUCT SELECTION GUIDE Barnstead I Thermolyne 165 800-553-0039 Ultraviolet Oxidation/Ultrafiltration (UV/UF) Water Systems Description Applications

175 800-553-0039Barnstead I Thermolyne

N A N O P U R E ® I N F I N I T Y U V / U F

D e i o n i z a t i o n

General SpecificationsOverall Dimensions Maximum Inlet

W x H x D Pressure Weight TemperatureInches (cm) psig Lbs (kg) ºF (ºC)

W H D

20 (51) 24 (61) 16 (41) 100 psig 80 (36.3) 40-120ºF(4-49ºC)

Product flow rates up to 1.8 L/min dependent upon feed water pressure and installed modules.

NANOpure Infinity UV/UF SystemElectrical

Model # Description Volts Amps Price

D8991 UV/UF 120 3

D8992-33 UV/UF 230 2

-33 Models CE Marked.

Cartridge Kits (sold separately) & AccessoriesModel # Descriptions Capacity Price

D50256 Type 1 Cartridge Kit Tap/DI Feed 2037 Grains 1 ea. D50251, 3 ea. D50253, 2 ea. FL703X2 as NaCl

D50257 Type 1 Cartridge Kit R/O or Dist. Feed 2037 Grains1 ea. D50250, 3 D50253, 2 ea. FL703X2 as NaCl

D50254 ORGANICfree Cartridge Kit Tap/DI Feed 1686 Grains 1 ea. D50251, 2 ea. D50253, 1 ea. D50252, as NaCl2 ea. FL703X2

D50255 ORGANICfree Cartridge Kit R/O or Dist. 1686 Grains Feed. 1 ea. D50250, 2 ea. D50253, 1 ea. as NaClD50252, 2 ea. FL703X2

D50258 Sanitization Cartridge N/A

FL898X1 Ultrafilter 5000 mw N/A

LMX13 UV Lamp Replacment N/A

FL550X1 40,000 mw Ultrafilter Replacement N/A

U.S. Patent Issued: 5,397,468; 5,399,263

B E N E F I T S

Includes all of the benefits of aNANOpure Infinity base system,NANOpure Infinity UF andNANOpure Infinity UV plus thefollowing added benefits:

• Produces up to 1.8 LPM ofwater with resistivities up to18.3 megohm-cm, organics < 2ppb, pyrogens < 0.001 Eu/mland no detectable RNase,DNase and DNA.

• The ideal system for allbiological research includingDNA amplification proceduresthat require the presence ofRNA to ensure optimumyields.

• No need for D.E.P.C. toguarantee Nuclease free water.

• The use of ultraviolet oxidationand ultrafiltration inconjunction with the latestadvances in ion exchange resinensures the total removal of awide class of impurities suchas ions, organics, pyrogens andnucleases.

The NANOpure Infinity UV/UF is the ultimate water purification system. It employs several water purification technologies providing you

water free of virtually all contamination. It is the only water treatment system that has demonstrated the ability to remove nucleases such as

RNase and DNase as well as DNA even when challenged with known concentrations.

• Produces ultimate purity at alower cost per liter thancompetitive models.

• Automatic and manual flushmodes on the UF and UV/UFmodels provides youconsistent and effectivecleaning of the ultrafiltermembrane.

• Two year warranty.

A P P L I C A T I O N S• Ion free water - AA, ICP,

ICP/MS

• Pyrogen free water, tissueculture and cell culture

• Organic free water, HPLC andGC/MS

• DNA Amplification

NANOpure Infinity UV/UF

RNase freewater…with theUV/UF wehave proven wecan do it2 year warranty

new

CATALOG3NEW 3/17/98 2:18 PM Page 175

Page 7: PRODUCT SELECTION GUIDE - Cole-Parmer · PRODUCT SELECTION GUIDE Barnstead I Thermolyne 165 800-553-0039 Ultraviolet Oxidation/Ultrafiltration (UV/UF) Water Systems Description Applications

176 800-553-0039Barnstead I Thermolyne

D e i o n i z a t i o n

N A N O P U R E ® I N F I N I T Y U P G R A D E M O D U L E S

new

NANOpure Infinity UpgradeModules

The NANOpure Infinity Baseunit can be upgraded in your labto produce water suitable for anyof your pure water needs. If youexpand your laboratory theNANOpure Infinity can beexpanded to provide water forany of your pure water needs.You can easily add thesemodules to your Infinity in yourlaboratory in only a few minutes.

If you need biological pure waterfor RNA or DNA studies, aUV/UF module can be added. Ifyou need water guaranteed to befree of pyrogens for tissueculture, IVF applications ormonoclonal antibody productionyou can add a UF module. If youneed low TOC water for yourcritical HPLC or GC/MSapplications a UV module canbe added.

N.I.S.T. Calibration Module

• Allows you to calibrate yourNANOpure Infinity in yourlaboratory verified to N.I.S.T.traceable standards.

• Comes complete with acertificate verifying N.I.S.T.standards.

• Calibration Module can bereturned for recertification.

• NANOpure Infinity is easilychecked and recalibrated inthe laboratory.

Inlet Cell Option

An inlet cell can be added toyour NANOpure Infinityallowing you to monitor thepurity of your feedwater on aconstant basis. No longer willyou have to guess at the purityof your feedwater. The inlet cellwill tell you exactly what yourresistivity, conductivity or ppmtotal dissolved solids is.

• Provides a digital reading ofthe resistivity, conductivity ortotal dissolved solids of yourincoming water.

• Easily added to an existingNANOpure Infinity in yourlaboratory.

NANOpure Infinity Upgrade ModulesModel # Descriptions Price

D8974 UV Module

D8984 UF Module

D8994 UV/UF Module

Nanopure Infinity AccessoriesE896X5 N.I.S.T. Calibration Module

E896X3 Inlet Cell

D2706 Pressure Switch

D8964 Low Water Pump Protector

Sometimes, change is good. Chameleons change their color to adapt to their surroundings. Fashions change each year keeping up with the

current trends. Now, your NEW NANOpure Infinity has been designed to change, with you, as your pure water needs change. Upgrade

modules, added to your NANOpure Infinity, allow you to change your current water system to produce water for needs from RNase to T.O.C.

to pyrogen removal.

NANOpure Infinity ModulesUV Module

UF Module

Allows you toupgrade yourwater system withyour needs.

CATALOG3NEW 3/17/98 2:18 PM Page 176

Page 8: PRODUCT SELECTION GUIDE - Cole-Parmer · PRODUCT SELECTION GUIDE Barnstead I Thermolyne 165 800-553-0039 Ultraviolet Oxidation/Ultrafiltration (UV/UF) Water Systems Description Applications

177 800-553-0039Barnstead I Thermolyne

N A N O P U R E ® I N F I N I T Y T E S T R E S U L T S

D e i o n i z a t i o n

The NANOpure Infinity has set a new standard for reagent grade water systems. The proven independent results attained from the various

models prove just how pure it is. Don’t be fooled by those that say their systems can produce water that meets your critical requirements.

Barnstead anticipated your needs for pure water and has performed virtually all the tests that you may need. We searched the world over for

instruments that provide the lowest accurate test detection limits for virtually any applications including RNase, DNase & DNA, GC/MS,

HPLC, ICP/MS, graphite furnace AA, bacterial endotoxins (Pyrogens), and bacteria.

The Total Organic Carbon (T.O.C.) of a water sample indicates its general organiccontent. It does not specify which types of organic compounds are present in the watersample. It does indicate how well a particular ultrapure water system is able to removeorganic molecules.

To determine specific organic compounds in a water sample, organic determinantanalyses such as H.P.L.C. and/or GS/MS are necessary. These tests identify the presenceand concentration of individual organic molecules that form the T.O.C. content of a watersample. This is important in environmental testing applications and all organicdeterminant analyses, where specific organic compounds are quantified.

HPLC 210 nm

T.O.C. Analysis1,2

Base System < 4 ppbUV System < 1 ppbUV/UF System < 2 ppbUF System < 10 ppb

1Feed water Tap, Distilled, Deionized

2Seivers model 800 Total Organic Carbon Analyzer

GC/MS – ALL UNITS1*

Volatile Result Units

Acetone < 10 µg/LAcrolem < 10 µg/LAcrylein < 10 µg/LAcrylonitrile < 10 µg/LBenzene < 0.5 µg/LBromodichloromethane < 0.5 µg/LBromoform < 0.5 µg/LBromomethane < 0.5 µg/LCarbon tetrachloride < 0.5 µg/LChlorobenzene < 0.5 µg/LChloroethane < 0.5 µg/LChloroform < 0.5 µg/LChloromethane < 0.5 µg/LDibromochloromethane < 0.5 µg/L1,1 - Dichloroethane < 0.5 µg/L1,2 - Dichloroethane < 0.5 µg/L1,1 - Dichloroethene < 0.5 µg/Ltrans - 1,2 - Dichloroethene < 0.5 µg/Lcis - 1,2 - Dichloroethene < 0.5 µg/L1,2 - Dichloropropane < 0.5 µg/Lcis - 1,2 - Dichloropropene < 0.5 µg/Ltrans - 1,3 - Dichloropropene < 0.5 µg/LEthylbenzene < 0.5 µg/L2 - Hexanone < 0.5 µg/LMethyl ethyl ketone (MEK) < 0.5 µg/LMethyl isobutyl ketone (MIBK) < 0.5 µg/LMethylene chloride < 0.5 µg/L1,1,2,2 - Tetrachloroethane < 0.5 µg/LTetrachloroethene < 0.5 µg/LToluene < 0.5 µg/L1,1,1 - Trichloroethane < 0.5 µg/L1,1,2 - Trichloroethane < 0.5 µg/LTrichlorofluoromethane < 0.5 µg/LVinyl chloride < 0.5 µg/LXylenes, Total < 0.5 µg/L

1 Volatile organic compounds base/neutrals, acid extractable organic

compounds and phthalate esters

* Hewlett Packard HP-5970A Mass. Spec.GC Keystone Laboratories

HPLC 254 nm

NOTE: NANOpure UV distilled feed 0.2

micron filter determined with a

Beckman® HPLC system; 168 detector at

210 nm and 254 nm, 4.6 x 250 nm C-18

column Direct-Connect™ Guard column

.05 AUFS; linear gradient mobile phase

from 100% water to 100% acetonitrile at

2 mls/minute in 30 minutes, 60 ml sample

enrichment at 2 mls/minute.

O R G A N I C D E T E R M I N A N T A N A L Y S I S

CATALOG3NEW 3/17/98 2:18 PM Page 177

Page 9: PRODUCT SELECTION GUIDE - Cole-Parmer · PRODUCT SELECTION GUIDE Barnstead I Thermolyne 165 800-553-0039 Ultraviolet Oxidation/Ultrafiltration (UV/UF) Water Systems Description Applications

178 800-553-0039Barnstead I Thermolyne

N A N O P U R E ® I N F I N I T Y T E S T R E S U L T S

D e i o n i z a t i o n

The inorganic purityof water is based onthe ability of theNANOpure Infinityto remove chargedparticles present invarious forms ofsupply water to theNANOpure Infinity.The listed resultsindicate thecapability of theNANOpure Infinityto remove ionicimpurities down tothe lowest availabledetection limits fromsome of today’s mostsensitiveinstrumentation.Barnstead sought outindependentlaboratories to conduct a battery of tests utilizing the productwater from the NANOpure Infinity. An abbreviated set ofresults is listed above. A complete set of results can beobtained by contacting Barnstead|Thermolyne.

“ The results over a four week period show that the NANOpure Infinitysystem was able to remove all detectable DNA, DNase and RNaseA/T contamination even after source water had been spiked with highlevels of each contaminant. We would recommend the system as a reliablesource of water free of DNA, DNase and RNase.”

MO BIO LABORATORIES

Life Sciences require the ultimate in biologically pure water.Bacteria, pyrogens, nucleases and DNA, if present, can effectyour results. Barnstead evaluated the NANOpure Infinityproviding you reproducible results on the ability of the unitsto remove these impurities.

INORGANICDETERMINANT ANALYSIS1

Element Symbol Results (ppb)

Aluminum** Al < 0.05Arsenic** As < 0.2Barium** Ba < 0.01Cadmium* Cd < 0.002Calcium* Ca < 0.05Chromium* Cr < 0.01Cobalt** Co < 0.04Copper* Cu < 0.02Iron* Fe < 0.02Lead* Pb < 0.05Magnesium* Mg < 0.004Manganese* Mn < 0.01Mercury** Hg < 0.05Nickel* Ni < 0.05Silver* Ag < 0.005Sodium* Na < 0.05Titanium** Ti < 0.2Zinc* Zn < 0.001

* GFAA – Perkin Elmer Model 1100B

** ICP/MS – Spectroflame EOP Ultrasonic

DNA CHALLENGE

Challenge Concentration – 100 mls of distilled water with 30 microliters of Human genomic DNA (0.234

microgram/microliter). Concentration in the 100 ml spike was 70 ng/ml.

A B C D E F G H I

Lane A – After 500 ml flushLane B – After 1000 ml flushLane C – After 1500 ml flushLane D – After 2000 ml flushLane E – After 2500 ml flush

Lane F – After 3000 ml flushLane G – Negative control

sterile D.E.P.C. treated waterLane H – Positive spike controlLane I – Sensitivity control

RNase CHALLENGE

Challenge Concentration – 100 mls of distilled water with 4 microliters of RNase A/T1 cocktail (1.15 U/ml, 50 U/ml

respectively). Concentration in the 100 ml spike was 0.046 U/ml A and 2 U/ml T1.

Lane A – After 500 ml flushLane B – After 1000 ml flushLane C – After 1500 ml flushLane D – After 2000 ml flush

Lane E – After 2500 ml flushLane F – After 3000 ml flushLane H – Positive spike controlLane I – Sensitivity control

DNase CHALLENGE

Challenge Concentration – 100 mls of distilled water with 428 microliters of 200 U/microliter DNase 1. Concentration

in the 100 ml spike was 856 U/ml.

Lane A – After 500 ml flushLane B – After 1000 ml flushLane C – After 1500 ml flushLane D – After 2000 ml flushLane E – After 2500 ml flush

Lane F – After 3000 ml flushLane G – Negative control

sterile D.E.P.C. treated waterLane H – Positive spike controlLane I – Sensitivity control

I N O R G A N I CD E T E R M I N A N T A N A L Y S I S

L I F E S C I E N C E A P P L I C A T I O N S

Pyrogens < 0.001 Eu/ml*> 5 log reduction

Bacteria - 0 CFU/ml**

* Bio. Whitaker Kinetic QCL-LAL

** A.S.T.M. Method F1094

A B C D E F G H I

A B C D E F G H I

CATALOG3NEW 3/17/98 2:18 PM Page 178

Page 10: PRODUCT SELECTION GUIDE - Cole-Parmer · PRODUCT SELECTION GUIDE Barnstead I Thermolyne 165 800-553-0039 Ultraviolet Oxidation/Ultrafiltration (UV/UF) Water Systems Description Applications

179 800-553-0039Barnstead I Thermolyne

E A S Y P U R E ® R F

D e i o n i z a t i o n

Cartridges & Accessories (sold separately)

Model # Descriptions Price

D50230 Pretreatment Deionized Feed

D50229 High Purity/Low TOC

D50231 Pretreatment Distilled or Reverse Osmosis Feed

D50233 Ultrapure

D7384 Wall Bracket

D50245 Sanitization Cartridge

D7034 Set of 2 Empty EASYpure Cartridges, Required for Sanitization

FL703X2 Filter 0.2 Micron with Filling Bell

Patents issued: Des. 347, 25B; 5, 397, 468; 5, 399, 263

B E N E F I T S

• Portable reservoir feed system requires no piping or special installation. Ideal for work areas where direct plumbing is not available.

• Provides less than 5 ppb total organic carbon (TOC) and up to 18.3 megohm-cm resistivity.

• Ideal for analytical procedures requiring water to be free of organics, inorganics and bacteria.

• Allows ultrapure water to be placed within easy access of analytical instruments.

• Capable of delivering 0.5 liters of ultrapure water per minute.

• The EASYpure RF provides optimum low cost service for laboratories needing less than 15 liters of water daily.

• It features an integral non-contaminating feedwater reservoir that stores 6.5 liters of water. Simply pour pretreated feedwater into the easily accessible reservoir.

• Feedwater must be pretreated by reverse osmosis, distillation,or deionization.

• Product water exceeds all ASTM, NCCLS and CAP Type 1 water standards.

• Independent laboratory testing confirms product water to be Type 1, organic-free and ultra-pure.

• Microprocessor-controlled purity monitor provides digital resistivity readings, temperature compensated to 25°C.

• A “stand-by” mode recirculates the purified water for 10 minutes every hour of inactivity.Water remains clean and free from recontamination and ready

to use when you need it.

• The system’s compact design allows it to be used anywhere on a bench with no installation or permanent plumbing connections required. An optional bracket is available for easy wall mounting.

Cartridge cavity.

Filtered reservoir cap prevents the introduction of airborne contaminants.

Yes, you can take it with you. Barnstead’s EASYpure RF reservoir feed Type 1 ultrapure water system is lightweight and

completely portable.You can take it where you need it, when you need it. Without special installation, permanent connections,

or piping. It’s ideal for applications when you need pure water free of organics, inorganics, and bacteria.

EASYpure RF

Overall Dimensions Shipping Maximum Inlet InletElectrical Inches (cm) Weight Pressure Temp Maximum Flow

Model # (50/60 Hz) W D H Lbs (kg) (psig) °F (°C) Rates (L/min) Price

D7031 120 VAC 12.25 (31.1) 18.50 (47.0) 18.13 (46.0) 35 (15.8) 100 40–120 (4–49) 0.5

D7033-33 240 VAC 12.25 (31.1) 18.50 (47.0) 18.13 (46.0) 35 (15.8) 100 40–120 (4–49) 0.5

-33 Models CE Marked

• Excellent for your most critical analytical applications including:

– High performance liquid chromatography (HPLC)

– Atomic absorption (AA)– Total organic carbon

(TOC)– Gas chromatography/mass

spectrometry (GC/MS)

– ICP and ICP/MS

– Ion chromatography (IC)

• All component materials are constructed of extremely inert materials to ensure maximum ionic and organic purity.

PortableLong on QualityShort on Price

EASYpure RF

CATALOG3NEW 3/17/98 2:18 PM Page 179

Page 11: PRODUCT SELECTION GUIDE - Cole-Parmer · PRODUCT SELECTION GUIDE Barnstead I Thermolyne 165 800-553-0039 Ultraviolet Oxidation/Ultrafiltration (UV/UF) Water Systems Description Applications

180 800-553-0039Barnstead I Thermolyne

E A S Y P U R E ® L F

D e i o n i z a t i o n

Cartridges & Accessories (sold separately)

Model # Descriptions Price

D50230 Pretreatment Deionized Feed

D50229 High Purity/Low TOC

D50231 Pretreatment Distilled or Reverse Osmosis Feed

D50233 Ultrapure

D7384 Wall Bracket

D50245 Sanitization Cartridge

D7034 Set of 2 Empty EASYpure Cartridges, Required for Sanitization

FL703X2 Filter 0.2 Micron with Filling Bell

Patents issued: Des. 347, 25B; 5, 397, 468; 5, 399, 263

B E N E F I T S

• Flow rates of up to 1.5 liters per minute can be achieved, depending on feedwater pressure. System can be fed directly from a pressurized feed line or a storage tank using gravity flow.

• Ideal for laboratories requiring a low cost ultrapure water system.

• Microprocessor-controlled purity monitor provides digital resistivity readings, temperature compensated to 25°C.

• Water exceeds all ASTM, NCCLS and CAP Type 1

water standards.• Produces Type 1, ultrapure

water for your critical analytical applications including:–Atomic absorption (AA) –ICP–Gas chromatography/Mass Spectrometry (GC/MS)–ICP/MS–Ion chromatography (IC)

• Provides less than 10 ppb total organic carbon (TOC) and up to 18.3 megohm-cm resistivity.

• The system’s compact design allows it to be wall mounted

or used anywhere on a bench. An optional bracket is available for easy wall mounting.

• A “stand-by” mode recirculates the purified water for 10 minutes every hour of inactivity. Water remains clean and free from recontamination.

• Feedwater must be pretreated by reverse osmosis, distillation, or deionization.

• Several cartridge types are available to adapt to your

specific feedwater source and application requirements.• Incorporates an absolute

0.2 micron hollow fiber final filter providing water free of particles and bacteria.

Cartridge cavity.

Short on room but long on purity requirements? You need our line feed Type 1 ultrapure water system.

With a compact, space-saving design that’s easy to tuck away in the lab yet delivers top purification for

procedures requiring water free of inorganics and bacteria, this unit is small and powerful.

EASYpure LF

Overall Dimensions Shipping Max Inlet InletElectrical Inches (cm) Weight Pressure Temp Maimum Flow

Model # (50/60 Hz) W D H Lbs (kg) (psig) °F (°C) Rates (L/min) Price

D7381 120 VAC 12.25 (31.1) 18.75 (47.6) 18.13 (46.0) 35 (15.8) 100 40–120 (4–49) 1.5*

D7382-33 240 VAC 12.25 (31.1) 18.75 (47.6) 18.13 (46.0) 35 (15.8) 100 40–120 (4–49) 1.5*

* Maximum flow rates dependent upon minimum inlet pressure of 30 psig and 60 Hz electricity.-33 models CE Marked.

• All component materials are constructed of extremelyinert materials to ensure maximum ionic and organic purity.

0.2 micron filter removesparticles and bacteria at theproduct water outlet.

Up to 18.3megohm-cmresistivity

Great for low volumerequirements!

EASYpure LF

CATALOG3NEW 3/17/98 2:18 PM Page 180

Page 12: PRODUCT SELECTION GUIDE - Cole-Parmer · PRODUCT SELECTION GUIDE Barnstead I Thermolyne 165 800-553-0039 Ultraviolet Oxidation/Ultrafiltration (UV/UF) Water Systems Description Applications

181 800-553-0039Barnstead I Thermolyne

D e i o n i z a t i o n

E A S Y P U R E ® U F

Cartridges & Accessories (sold separately)

Model # Descriptions Price

D50230 Pretreatment Deionized Feed

D50229 High Purity/Low TOC

D50231 Pretreatment Distilled or Reverse Osmosis Feed

D50233 Ultrapure

D7384 Wall Bracket

D50245 Sanitization Cartridge

D7034 Set of 2 Empty EASYpure Cartridges, Required for Sanitization

FL703X2 Filter 0.2 Micron with Filling Bell

Patents issued: Des. 347, 25B; 5, 397, 468; 5, 399, 263

B E N E F I T S

• The 10,000 molecular weight ultrafilter provides less than 0.005 EU/ml pyrogen levels and greater than a 5 log reduction.

• An automatic intermittent flush cleans the ultrafilter without wasting valuable high purity water.

• Capable of delivering up to 1.5 liters of pure, pyrogen-free* water per minute.

• Microprocessor-controlled purity monitor provides digital resistivity readings, temperature compensated to 25°C.

• A “stand-by” mode recirculates the purified water for 10 minutes every hour of inactivity. Water remains clean and free from recontamination.

• Water exceeds all ASTM, NCCLS, and CAP Type 1 and Type A water purity standards.

• Provides low cost biologically pure water with less than 10 ppb total organic carbon (TOC)and up to 18.3 megohm-cm resistivity.

• Feedwater must be pretreated using reverse osmosis, distillation or deionization.

• Water is filtered at the point of use with an absolute 0.2 micron hollow fiber filter.

• The system’s compact design allows it to be wall mounted or used anywhere on a bench. An optional bracketis available for easy wall mounting.

• All component materials are constructed of extremely inert materials to ensure maximum ionic and organic purity.

*Pyrogen=Gram negative bacterial lipopolysaccharides (LPS)

Cartridge cavity.

Removing unwanted pyrogens for low volume work is easy with our line-fed, bioresearch-grade water system.

In fact, we like to think that this is the perfect pyrogen-free Type 1 reagent water grade water system for cell and tissue

cultures. With water that exceeds all ASTM, NCCLS, and CAP Type 1 water standards, we think you’ll agree.

EASYpure UF

Overall Dimensions Shipping Max Inlet InletElectrical Inches (cm) Weight Pressure Temp Max Flow

Model # (50/60 Hz) W D H Lbs (kg) (psig) °F (°C) Rates (LPM) Price

D7411 120 VAC 12.25 (31.1) 18.75 (47.6) 18.13 (46.0) 35 (15.8) 100 40–120 (4–49) 1.5*

D7412-33 240 VAC 12.25 (31.1) 18.75 (47.6) 18.13 (46.0) 35 (15.8) 100 40–120 (4–49) 1.5*

* Maximum flow rates dependent upon minimum inlet pressure of 30 psig and 60 Hz electricity.-33 Models CE Marked.

Wall bracket with rotation base permits easy cartridgereplacement.

0.2 micron filter removesparticles and bacteria at the product water outlet.

Pyrogen freewater for yourLife Science applications.

EASYpure UF

CATALOG3NEW 3/17/98 2:18 PM Page 181

Page 13: PRODUCT SELECTION GUIDE - Cole-Parmer · PRODUCT SELECTION GUIDE Barnstead I Thermolyne 165 800-553-0039 Ultraviolet Oxidation/Ultrafiltration (UV/UF) Water Systems Description Applications

182 800-553-0039Barnstead I Thermolyne

E A S Y P U R E ® U V

D e i o n i z a t i o n

Cartridges & Accessories (sold separately)

Model # Descriptions Price

D50230 Pretreatment Deionized Feed

D50229 High Purity/Low TOC

D50231 Pretreatment Distilled or Reverse Osmosis Feed

D50233 Ultrapure

D7384 Wall Bracket

D50245 Sanitization Cartridge

D7034 Set of 2 Empty EASYpure Cartridges, Required for Sanitization

FL703X2 Filter 0.2 Micron with Filling Bell

Patents issued: Des. 347, 25B; 5, 397, 468; 5, 399, 263

B E N E F I T S

• Provides superior low cost water to meet the stringent requirements demanded by your critical organic determinant analyses.

• Provides less than 2 parts per billion (ppb) total organic carbon (TOC) and up to 18.3 megohm-cm resistivity. (Independent laboratory testing produced water with

in-line TOC levels below 1 ppb.)

• Ideal for applications including: – High performance

liquid chromatography (HPLC)

– Ion chromatography (IC) – Gas chromatography/mass

spectrometry (GC/MS) analysis.

• The dual wavelength ultraviolet light (185 and254 nm) oxidizes organics and controls bacterial growth. Exceeds all ASTM,

NCCLS and CAP Type 1 water purity standards.

• Capable of delivering up to 1.5 liters of pure water

per minute dependent on incoming water pressure.

• The system’s compact design allows it to be wall mounted or used anywhere on a bench. An optional bracketis available for easy wall mounting.

• A “stand-by” mode recirculates the purified water for 10 minutes every hour of inactivity. Water remains clean and free from recontamination.

• The system filters water at the point of use with an absolute 0.2 micron hollow fiber filter to remove particles and bacteria at the product water outlet.

• All component materials are constructed of extremely inert materials to ensure maximum ionic and organic purity.

Cartridge cavity.

Pure as the driven snow—if the snow, by chance, exceeded all ASTM NCCLS, and CAP Type 1 water

purity standards. That’s what our ultraviolet ultrapure system delivers. It provides superior water purity

for your most critical organic determinant analyses, such as HPLC and GC/MS.

EASYpure UV

Overall Dimensions Shipping Max Inlet InletElectrical Inches (cm) Weight Pressure Temp Max Flow

Model # (50/60 Hz) W D H Lbs (kg) (psig) °F (°C) Rates (L/min) Price

D7401 120 VAC 12.25 (31.1) 18.25 (46.4) 18.5 (47.0) 30 (13.6) 100 40–120 (4–49) 1.5*

D7402-33 240 VAC 12.25 (31.1) 18.25 (46.4) 18.5 (47.0) 30 (13.6) 100 40–120 (4–49) 1.5*

* Maximum flow rates dependent upon minimum inlet pressure of 30 psig and 60 Hz electricity.-33 models CE marked.

• Feedwater must be pretreated by using reverse osmosis, distillation, or deionization.

• Microprocessor-controlled purity monitor provides digital resistivity readings, temperature compensated to 25°C.

Wall bracket with rotation base permits easy cartridgereplacement.

Perfect foryour organic determinantapplications.

EASYpure UV

CATALOG3NEW 3/17/98 2:18 PM Page 182

Page 14: PRODUCT SELECTION GUIDE - Cole-Parmer · PRODUCT SELECTION GUIDE Barnstead I Thermolyne 165 800-553-0039 Ultraviolet Oxidation/Ultrafiltration (UV/UF) Water Systems Description Applications

183 800-553-0039Barnstead I Thermolyne

D e i o n i z a t i o n

E A S Y P U R E ® U V / U F

Cartridges & Accessories (sold separately)

Model # Descriptions Price

D50230 Pretreatment Deionized Feed

D50229 High Purity/Low TOC

D50231 Pretreatment Distilled or Reverse Osmosis Feed

D50233 Ultrapure

D7384 Wall Bracket

D50245 Sanitization Cartridge

D7034 Set of 2 Empty EASYpure Cartridges, Required for Sanitization

FL703X2 Filter 0.2 Micron with Filling Bell

Patents issued: Des. 347, 25B; 5, 397, 468; 5, 399, 263

B E N E F I T S

• Product water displays no RNAdegradation when challenged with various concentrations of RNase A and RNase T1.

• Validated as being RNase and DNase free.

• Capable of delivering a flow rate of up to 1.3 liters per minute.

• Processes low cost pyrogen-free water for tissue and cell cultures and monoclonal antibody production (Pyrogen levels measure less than 0.005 EU/ml).

• Ultrapure product water has bacteria levels measuring less than 1 CFU/100 ml.

• Water exceeds all ASTM, NCCLS, and CAP Type 1 water standards.

• Microprocessor-controlled purity monitor provides digital resistivity readings, temperature compensated to 25°C.

• Produces ion-free water for applications including:

– Atomic absorption (AA) – Gas chromatography/mass

spectrometry (GC/MS)

–Ion chromatography (IC)–ICP and ICP/MS

• Processes organic-free water for applications including: – High performance liquid

chromatography (HPLC)– Gas chromatography/mass

spectrometry (GC/MS).

– Total organic carbon analysis (TOC)

HPLC chromatograms show flatbaselines at 254 nm and the

more sensitive 210 nm wavelength.

• Provides water with less than 3 parts per billion (ppb) total organic carbon (TOC) and up to 18.3 megohm-cm resistivity.

• A “stand-by” mode recirculates the purified water for 10 minutes every hour of inactivity. Water remains clean and free from recontamination.

Cartridge cavity.

Complete. Compact. Critical. This superior Barnstead water purification system is the most comprehensive

on the market, employing these technologies: deionization, ultraviolet oxidation, and ultrafiltration.

Water purified by this unit will not only meet your most critical Life Science applications—including

DNA amplification and cell culture—it will meet your highest expectations.

EASYpure UV/UF

Overall Dimensions Shipping Max Inlet InletElectrical Inches (cm) Weight Pressure Temp Max Flow

Model # (50/60 Hz) W D H Lbs (kg) (psig) °F (°C) Rates (L/min) Price

D8611 120 VAC 12.3 (31.1) 18.75 (47.6) 18.13 (46.0) 35 (15.8) 100 40–120 (4–49) 1.3*

D8612-33 240 VAC 12.3 (31.1) 18.75 (47.6) 18.13 (46.0) 35 (15.8) 100 40–120 (4–49) 1.3*

* Maximum flow rates dependent upon minimum inlet pressure of 30 psig and 60 Hz electricity.

-33 Models CE Marked.

• Feedwater must be pretreated by reverse osmosis, distillation, or deionization.

• The system’s compact design allows it to be wall mounted or used anywhere on a bench.

An optional bracket is available for easy wall mounting.

RNase Free waterThe most completesystem on the market.

EASYpure UV/UF

• All component materials are constructed of extremely inert materials to ensure maximum ionic and organic purity.

CATALOG3NEW 3/17/98 2:18 PM Page 183

Page 15: PRODUCT SELECTION GUIDE - Cole-Parmer · PRODUCT SELECTION GUIDE Barnstead I Thermolyne 165 800-553-0039 Ultraviolet Oxidation/Ultrafiltration (UV/UF) Water Systems Description Applications

184 800-553-0039Barnstead I Thermolyne

Organics

Volatile Compounds Result Units

Acetone < 20.0 µg/LAcrolein < 50.0 µg/LAcrylonitrile < 50.0 µg/LBenzene < 1.0 µg/LBromodichloromethane < 1.0 µg/LBromoform < 1.0 µg/LBromomethane < 10.0 µg/LCarbon tetrachloride < 1.0 µg/LChlorobenzene < 1.0 µg/LChloroethane < 10.0 µg/LChloroform < 1.0 µg/LChloromethane < 10.0 µg/LDibromochloromethane < 1.0 µg/L1,1–Dichloroethane < 1.0 µg/L1,2–Dichloroethane < 1.0 µg/L1,1–Dichloroethene < 1.0 µg/Ltrans–1,2–Dichloroethene < 1.0 µg/Lcis–1,2–Dichloroethene < 1.0 µg/L1,2–Dichloropropane < 1.0 µg/Lcis–1,3–Dichloropropene < 1.0 µg/Ltrans–1,3–Dichloropropene < 1.0 µg/LEthylbenzene < 1.0 µg/L2–Hexanone < 10.0 µg/LMethylethyl ketone (MEK) < 10.0 µg/LMethylisobutyl ketone (MIBK) < 10.0 µg/LMethylene chloride < 10.0 µg/L1,1,2,2–Tetrachloroethane < 1.0 µg/LTetrachloroethene < 1.0 µg/LToluene < 1.0 µg/L1,1,1–Trichloroethane < 1.0 µg/L1,1,2–Trichloroethane < 1.0 µg/LTrichloroethene < 1.0 µg/LTrichlorofluoromethane < 1.0 µg/LVinyl chloride < 10.0 µg/LXylenes, Total < 1.0 µg/L

NOTE: Volatile organic compounds determined by Hewlett Packard HP-5970A Mass Spec GC.

E A S Y P U R E T E S T R E S U L T S

D e i o n i z a t i o n

Independent Test Results for EASYpure RF & UF

Independent Test Results for All Units

EASYpure UV EASYpure UV/UF

NOTE: EASYpure RF, LF, UV & UV/UF distilled feed 0.2 micron filter determined with aBeckman® HPLC system; 168 detector at 210 nm and 254 nm, 4.6 x 250 nm C-18 column Direct-Connect™ Guard column .05 AUFS; linear gradient mobile phase from 100% water to 100%acetonitrile at 2 mls/minute in 30 minutes, 60 ml sample enrichment at 2 mls/minute.

Indendent test data consistently confirm EASYpure’s ability to provide flat baselines in HPLC.The chromatogram below indicates readings of test run at 254 nm, and how impressiveEASYpure baselines remain when tested at the much more sensitive level of 210 nm.

Metals

Chemical Element EASYpure resultsSymbol Name (PPB or micrograms/liter)

Ag Silver < 0.005Cd Cadmium < 0.003Ca Calcium < 0.05Cr Chromium < 0.01Cu Copper < 0.02Pb Lead < 0.05Ni Nickel < 0.1Zn Zinc < 0.001Mg Magnesium < 0.004Mn Manganese < 0.01Na Sodium < 0.02

NOTE: Metals determined by Perkin Elmer 1100B GraphicFurnace AA.

RNase Challenge Challenge 10 ug/ml RNase A and 200 KU/ml T1

Lane A after 1000 ml flushLane B after 1500 ml flushLane C after 1600 ml flushLane D after 1700 ml fluchLane E after 1800 ml flushLane F after 1900 ml flushLane G negative controlLane H positive control

Lane I after 2000 ml flushLane J after 2100 ml flushLane K after 2200 ml flushLane L after 3 liter flushLane M after 5 liter flushLane N after 10 liter flushLane O negative controlLane P positive control

Gel 1. a b c d e f g h

7kb-

Gel 2. i j k l m n o p

7kb-

CATALOG3NEW 3/17/98 2:18 PM Page 184

Page 16: PRODUCT SELECTION GUIDE - Cole-Parmer · PRODUCT SELECTION GUIDE Barnstead I Thermolyne 165 800-553-0039 Ultraviolet Oxidation/Ultrafiltration (UV/UF) Water Systems Description Applications

Cartridge Kits for E-pure™ Systems - Pretreatment Feed (sold separately)

Model # Descriptions Contents Price

D50227 4 Module Type I Cartridge Kit 1-D0835 Pretreatment Cartridge, 2-D5027 and 1-D0809 Ultrapure Cartridge,for Pretreated Feed

D50228 4 Module Type I ORGANICfree 1-D0836 MACROpure Cartridge, 1-D5027 Ultrapure Cartridges and 1-D0809 Cartridge Kit for Pretreated Feed Ultrapure Cartridges, 1-D5021 ORGANICfree Cartridge

D3750 Final Filter

185 800-553-0039Barnstead I Thermolyne

E-pure™ 3-Holder

Overall DimensionsElectrical Inches (cm) Shipping Weight Max Inlet Inlet Conn Max Flow

Model # (50/60 Hz) W D H Lbs. (kg) Pressure (psig) (Inches) Temp Range Rates Price

D4631 120 VAC 29 (73.7) 7.5 (19.1) 28 (71.1) 50 100 1/4 NPTF 40-120°F 2.0 LPM

D4632-33 240 VAC 29 (73.7) 7.5 (19.1) 28 (71.1) (22.7) 100 1/4 NPTF 4-49°C 2.0 LPM

-33 Models CE Marked

E - P U R E

D e i o n i z a t i o n

E-pure™ 4-Holder

Max Overall Dimensions Ship Max.Electrical Inches (cm) Weight Inlet Inlet Conn Max Flow

Model # (50/60 Hz) W D H Lbs. (kg) Pressure (psig) (Inches) Temp Range Rates Price

D4641 120VAC 35 ( 88.9) 7.5 (19.1) 28 (71.1) 56 100 1/4 NPTF 40–120˚F 2.0 LPM

D4642-33 240VAC 35 ( 88.9) 7.5 (19.1) 28 (71.1) (25.4) 100 1/4 NPTF 4–49˚C 2.0 LPM

-33 Models CE Marked

Cartridge Kits for E-pure™ Systems - Tap Feed (sold separately)

Model # Descriptions Contents Price

D5029 3 Module Type I Cartridge Kit 1-D0835 Pretreatment Cartridge, 2-D5027 Ultrapure Cartridges

D5028 4 Module Type I Cartridge Kit 1-D0835 Pretreatment Cartridge, 1-D0803 High Capacity Cartridge,2-D5027 Ultrapure Cartridges

D5022 3-Module Type I 1-D0836 MACROpure Cartridge, 1-D5027 Ultrapure Cartridge,ORGANICfree Cartridge Kit 1-D5021 ORGANICfree Cartridge

D5023 4 Module Type I 1-D0836 MACROpure Cartridge, 1-D0803 High Capacity Cartridge,ORGANICfree Cartridge Kit 1-D5027 Ultrapure Cartridge, 1-D5021 ORGANICfree Cartridge

Getting back to basics. It makes good sense. That’s why E-pure offers a basic

Type 1 reagent grade water system that meets the stringent requirements for Type 1 water—at the lowest cost.

But what about quality and performance? E-pure delivers both without compromise.You’re assured a purification system that’s highly

effective, safe, and free from contaminants and impurities.

B E N E F I T S• Resistivities up to 18.3

megohm-cm and TOC levels below 5 ppb.

• Virgin polypropylene water pathways preventrecontamination.

• Recirculation pump continuously recirculates water throughout the entire system to maintain water purity and reduce the quantity of waste water required for rinse-up.

• Wall mounted; completely assembled for easy installation.

• 1/4 turn quick release canisters allow for easy cartridge replacement.

• 0.2 micron absolute hollow fiber filter removes bacteria and particulates that could alter your results.

• Digital resistivity meter is automatically temperature compensated to 25°C, preventing fluctuating resistivity readings due to temperature changes.

• Flow rate up to 2 liters per minute.

EASYpure 4-holder

Lowest cost perliter1/4 turn quick

release canisters

CATALOG3NEW 3/17/98 2:18 PM Page 185

Page 17: PRODUCT SELECTION GUIDE - Cole-Parmer · PRODUCT SELECTION GUIDE Barnstead I Thermolyne 165 800-553-0039 Ultraviolet Oxidation/Ultrafiltration (UV/UF) Water Systems Description Applications

186 800-553-0039Barnstead I Thermolyne

B-pure™ Cartridge SystemsModel No. Descriptions Dimensions W x D x H Shipping Weights Electrical 50/60 Hz Price

D4511 Single Holder 7” x 7” x 24” 8 lbs. 120 VAC(17.8 x 17.8 x 61cm) (3.6 kg)

D4521 Double Holder 15” x 7” x 27” 15 lbs. 120 VAC38.1 x 17.8 x 68.6cm

D4522-33 Double Holder 15” x 7” x 27”38.1 x 17.8 x 68.6cm (6.8 kg) 240 VAC

D4505 1/2 Size Holder 7” x 6 5/8” x15” 6 lbs. 120 VAC(17.8 x 16.8 x 38.1cm) (2.7 kg)

-33 Models CE Marked

General Specifications for all B-puresInlet Temp. Max. Inlet Cell Thread Max. Flow FlowConnection Range Pressure Size Rate

1/2” NPTF 40-120°F (4-49°C) 100 psig 1⁄2” NPTF 4 liters/min.

Cartridges sold separately. See Cartridge page for selection.

B - P U R E C A R T R I D G E S Y S T E M S

D e i o n i z a t i o n

B E N E F I T SThe B-pure system providesyou the flexibility ofdesigning your own watersystem. The modular designallows you the ability to addadditional holders when theneed exists. If you need purewater of less quality than theNANOpure, E-pure, orEASYpure can produce, theB-pure is the proper systemfor you.• Produces up to 4 liters per

minute, depending upon feedwater quality

• Quarter-turn quick release canisters

• Accepts all Barnstead cartridges and filters (except hose nipple)

• Allows for the addition of holders as water needs change

• Accepts Pura®-Lite or digital purity meter

• 1⁄2 size holders utilize smaller cartridges to conserve space

Double Holder• Complete with draw-off

valve

• Digital temperature compensated purity meter included

• Can be ordered with Pura-Lite “Go/No Go” resistivityindicator (ContactBarnstead/Thermolyne for details.)

1⁄2 Size Cartridge Holder• Up to 2 liters per minute of

flow, depending upon feedwater quality

• Accepts a variety of purification cartridges

• Easily attaches to existing B-pure systems

• Small size allows for flexibility in mounting location

A P P L I C A T I O N SPoint-of-use deionization forlaboratories, electronicsindustry, and all users ofpure water.

Designyour ownwatersystem

1/2 Size B-Pure Single Holder B-Pure Double Holder B-Pure

Problem: your tap water is not quite pure enough for your requirements but you can’t justify a complete deionization system. Solution:

B-pure cartridge systems offer lower volume, moderate purity water at an affordable price. B-pure cartridge holders allow you to select size

and number of holders to meet your water purity needs. And if your needs change in the future, B-pure holders can be added to meet those

changing needs.

CATALOG3NEW 3/17/98 2:18 PM Page 186

Page 18: PRODUCT SELECTION GUIDE - Cole-Parmer · PRODUCT SELECTION GUIDE Barnstead I Thermolyne 165 800-553-0039 Ultraviolet Oxidation/Ultrafiltration (UV/UF) Water Systems Description Applications

187 800-553-0039Barnstead I Thermolyne

The advantages of hollowfiber filtration arenumerous. The material isnaturally hydrophilic thus itdoes not require the use ofwetting agents. Wettingagents or surfactants arecommonly used in otherfiltration material andrequire extensive rinse-upvolumes to achieve highpurity water. The filters usedin the remote dispenser arehollow fiber material andthus rinse to high resistivityand low T.O.C. values afteronly a few liters of water arerinsed through it. The natureof the fibers also allows youto gain greater flow rateswith a smaller filter.

R E M O T E D I S P E N S E R

D e i o n i z a t i o n

Convenience andpurityThe Remote

Dispenser has itall.

tion path, providing un-paralleled purity

- All wetted parts are virginpolypropylene or Teflon eliminating the possibilityof recontamination of your water.

• Included with theNANOpure Infinitysystem. Can be added tothe E-pure

• Delivers up to 1.5 liters ofwater per minute

• Comes complete with afinal filter

Remote Dispenser and FilterMax. Max. Operating FilterFlow Inlet Temperature Membrane Filter Shipping

Model # Rate Pressure Range Size Type Weights Price

Remote Dispenser

D8952 1.8 liters/min. 50 psig 40-120˚F _ _ 5 lbs. (2.3 kg)

Replacement Filter

FL703X2 1.8 liters/min. 50 psig 40-120˚F 0.2 micron Hollow Fiber 1 lb. (.5 kg)

B E N E F I T S• Assures optimum water

purity- Absolute filtration down

to 0.2 microns- Hollow fiber filter

material contains no extractables

- Virtually eliminates dead volume

- Allows for delivery of pure water up to 8 feet

(2.4 meters) away from the unit- Included in the recircula-

The Remote Dispenserprovides the ultimate in apure water delivery system.The unique design of thedispenser delivers purifiedwater to a remote locationwithout compromising thepurity of that water. Thedesign of the dispenserprovides for recirculation ofthe water up to the tip of thedispenser providing virtuallyno dead volume. This allowsyou to maintain the puritylevel within the system.

Are you tired of using a ladder to reach your water purification system? Eliminate that ladder and bring your pure water within reach.

Barnstead’s Remote Dispenser adapts to E-pure and older quad style NANOpure water purification systems delivering purified water up to 8

feet (2.4 meters) from your system. Recirculation of the water up to the tip of the dispenser ensures the purity of the water

through your entire system.

Remote Dispenser

CATALOG3NEW 3/17/98 2:18 PM Page 187

Page 19: PRODUCT SELECTION GUIDE - Cole-Parmer · PRODUCT SELECTION GUIDE Barnstead I Thermolyne 165 800-553-0039 Ultraviolet Oxidation/Ultrafiltration (UV/UF) Water Systems Description Applications

188 800-553-0039Barnstead I Thermolyne

A C C E S S O R I E S

D e i o n i z a t i o n

Depending on thedeionization system, certainaccessories are available.These can be easily added toeither new or existingsystems to provide thebenefits described below.

Digital Monitor• Provides a direct reading

of the resistivity of the water exiting the system

• Fits conveniently into B-pure, as well as any 1⁄2” (12.7 mm) NPTF opening

• Indicates actual water purity in megohm-cm, temperature compensated to 25°C.

Pura®-Lite• Provides “Go/No Go”

indication of water purity• Green light indicates

acceptable water purity, redlight indicates unacceptablepurity

• Easily fits into B-pure holder or any 1⁄2”(12.7 mm) NPTF connection

• Various values to provide more flexibility in your individual water system

NANOpure Low PressurePump ProtectorIf you are feeding aNANOpure, E-pure orEASYpure system from apressurized feed line, it is toyour advantage to ensure thatthe pump is fully protectedwith the use of theNANOpure low pressurepump protector.• Interrupts power if

feedwater pressure falls below 5 psig (0.35 kg/cm2)

• Includes 6’ (1.8 meters) cord which plugs directly into NANOpure, E-pure or EASYpure systems

• Complete with 1⁄4” (6 mm) NPT “T” to install in your feedline

Low Water Pump ProtectorIf feeding from a storagereservoir, it is recommendedthat a low water pumpprotector be added toNANOpure, E-pure orEASYpure systems to ensurethat the pump is protected inthe event the reservoir doesnot have a sufficient quantityof water to satisfy therequirements of the system.• Adaptable to most storage

reservoirs, providing a 1/2” (12.7 mm) NPTF connection is available

• Comes complete with 6’(1.8 meters) cord to attach directly to the NANOpure, E-pure or EASYpure systems

Flow MetersFlow meters allow precisemeasurement and controlflow of water through a B-pure system. They areinstalled in the inlet waterline. The float type metersare complete with anadjustable flow valve. Inletand outlet connections are1⁄2” (12.7 mm) NPTF.

NOTE: A flow meter cannot be used when a

Recirculating/Distribution Pump is part of a

B-pure system.

Digital Purity MonitorModel # Voltage Cell Thread Size Resistivity Range Price

D2770 120 VAC 1⁄2” NPTM (12.7 mm) 0.1-18.3 megohm-cm

D2769 240 VAC 1⁄2” NPTM (12.7 mm) 0.1-18.3 megohm-cm

Pura-LiteModel # Voltage Resistivity Cell Thread Size Price

E3450 120 VAC 50,000 ohms-cm 1⁄2” NPTM (12.7 mm)

E3454 240 VAC 50,000 ohms-cm 1⁄2” NPTM (12.7 mm)

E3451 120 VAC 200,000 ohms-cm 1⁄2” NPTM (12.7 mm)

E3455 240 VAC 200,000 ohms-cm 1⁄2” NPTM (12.7 mm)

E3452 120 VAC 1,000,000 ohms-cm 1⁄2” NPTM (12.7 mm)

E3456 240 VAC 1,000,000 ohms-cm 1⁄2” NPTM (12.7 mm)

NANOpure Low Pressure Pump ProtectorModel # Description Price

D2706 Pressure Switch

Low Water Pump ProtectorModel # Description Price

D0603 NANOpure® pump protector, 120V

D0606 NANOpure® pump protector, 240V

D8964 NANOpure Infinity™ pump protector, all models

CN56215 NANOpure pump protectorRequired for use with A56290-857 Tank, 120V

CN56210 NANOpure pump protector required foruse with A56290-857 Tank, 240V

Flow MetersModel # Description Price

D0787 Flow Meter, 1 to 75 lph

D0788 Flow Meter, 0 to 190 lph

CATALOG3NEW 3/17/98 2:18 PM Page 188

Page 20: PRODUCT SELECTION GUIDE - Cole-Parmer · PRODUCT SELECTION GUIDE Barnstead I Thermolyne 165 800-553-0039 Ultraviolet Oxidation/Ultrafiltration (UV/UF) Water Systems Description Applications

189 800-553-0039Barnstead I Thermolyne

Pressurized CartridgesCartridges feature all polypropylene construction and are designed to fit any NANOpure®, E-pure™, B-pure™, PCS, Bantam holder or cooling loop system.

Model # Description Resin Type(s) Where Used Price

D0803 High capacity High capacity, NANOpure, E-pure, B-pure,

two-bed Bantam, cooling loops

D0809 Ultrapure Mixed bed NANOpure II, older style NANOpure

systems, B-pure, Bantam, cooling loops

D0811 Oxygen removal Oxygen removal B-pure, cooling loops

D0813 Organic removal Activated carbon B-pure, cooling loops, Bantam

D0815 Cation removal Cation removal B-pure, cooling loops, Bantam

D0820 Organic free Organic free NANOpure II, older NANOpure systems

D5021 Organic free Organic free Quad-style NANOpure, E-pure

D0832 Pretreatment cartridge Mixed bed, organic removal B-pure, still pretreatment

D0835 Combination colloid, organic Macroreticular, organic removal NANOpure, E-pure, B-pure

D0836 Macropure Macroreticular, organic removal NANOpure, E-pure, pretreatment

for organic free

D8809 Two bed combination Ultrapure, oxygen removal B-pure, cooling loops

D8811 Three bed combination Ultrapure, oxygen removal,organic removal B-pure, cooling loops

D0760 Anion removal Anion removal B-pure, cooling loops, Bantam

D5027 Ultrapure Mixed bed Quad-style NANOpure, E-pure

I N D I V I D U A L C A R T R I D G E S

D e i o n i z a t i o n

Standard Specifications for Pressurized CartridgesLength Diameter Shipping Weight

17.2” (43.7 cm) 3.4” (8.6 cm) 5 lbs. (2.3 kg)

1/2 Size Cartridges for 1/2 Size B-Pure Cat. # Description Resin Type(s) Where Used Price

D50213 1⁄2 size Ultrapure mixed bed 1⁄2 B-pure

D50214 1⁄2 size oxygen removal oxygen removal 1⁄2 B-pure

D50215 1⁄2 size organic removal activated carbon 1⁄2 B-pure

D50216 1⁄2 size comb. oxygen oxygen removal 1⁄2 B-pureand demineralization mixed bed

D50217 1⁄2 size comb. carbon mixed bed 1⁄2 B-pureand demineralization activated carbon

Standard Specifications for 1/2 Sized CartridgesLength Diameter Shipping Weights

10.9” 3.4” 3 lbs. (1.4 kg)

NANOpure Infinity CartridgesModel # Description Resin Type(s) Where used Price

D50250 Pretreatment Cartridge R/O & Dist Feed Activated Carbon Nanopure Infinity

D50251 Pretreatment Cartridge DI & Tap Feed Activated Carbon & Macroreticular Resin Nanopure Infinity

D50252 Organic Free Cartridges Organic Free Media Nanopure Infinity

D50253 Ultrapure Mixed Bed Nanopure Infinity

CATALOG3NEW 3/17/98 2:18 PM Page 189

Page 21: PRODUCT SELECTION GUIDE - Cole-Parmer · PRODUCT SELECTION GUIDE Barnstead I Thermolyne 165 800-553-0039 Ultraviolet Oxidation/Ultrafiltration (UV/UF) Water Systems Description Applications

190 800-553-0039Barnstead I Thermolyne

H O S E N I P P L E C A R T R I D G E S & B A N T A M D E I O N I Z E R

D e i o n i z a t i o n

Hose nipple cartridges utilize the samesuperior quality resins used in PCScartridges. The 100% virginpolypropylene cartridge rinses to highquality quickly. Designed for non-pressure applications1, these cartridgesinclude 3⁄8” (1 cm) barbed hoseconnections on each end. All cartridges(except D8904 and D8911) containdyes which change color when resin isexhausted. Hose nipple cartridgeholder part #D8900.

Cat.# Description Resin Type(s) Capacity Length - Inches (cm) Price

D8822 1⁄2 size combination Ultrapure, oxygen removal 190 grains as NaCl 10.2 (25.9)Ultrapure,oxygen removal

D8901 High capacity High capacity, two bed 1725 grains as NaCl 18.7 (47.5)

D8902 Ultrapure Mixed bed 760 grains as NaCI to 1 megohm-cm endpoint 18.7 (47.5)

D8903 Oxygen removal Oxygen removal 11 liters S.T.P. (15 grains) 18.7 (47.5)

D8904 Organic removal Activated carbon NA 18.7 (47.5)

D8905 Cation removal Cation 2500 grains as NaCl 18.7 (47.5)

D8911 Ultrapure (no dye) Mixed bed 760 grains as NaCI to 1 megohm-cm endpoint 18.7 (47.5)

D8921 Pretreatment Activated carbon, mixed bed 1450 grains as NaCl 18.7 (47.5)

D8922 Combination organic removal, Activated carbon, mixed bed 600 grains as NaCl 18.7 (47.5)Ultrapure

D8950 2⁄3 size High capacity High capacity 1130 grains as NaCl 13.3 (33.8)

D8900 Hose Nipple Cartridge Holder

Standard Specifications

Min. Inlet Pressure Max. Inlet Pressure Diameter Nose Connection Shipping Weight5 psig 65 psig 3.4” (8.6 cm) 3⁄8” (1 cm) hose barb 5 lbs. (2.3 kg)

1Non-pressure refers to the inability of the cartridges to accept back pressure. Output water must be diverted to an atmospherically-vented receptacle.

B A N T A M D E I O N I Z E RB E N E F I T S• Produces 19 to 38 liters per hour• Can be used with any PCS

cartridge; is most often used withultrapure or high capacitycartridges

• Equipped with direct reading puritymeter

• Resistivity can be directly readfrom 25,000-18,000,000 ohms-cm

• Includes 3 ft. of inlet feed tubing

Bantam DeionizerElectrical Flow Rate Dimension Weight

Model # 50/60 Hz (max.) WxDxH lbs. (kg) Price

D0800 120 VAC 38 liters/hour 6" x 8.75" x 28.5" 15 lbs.

(15.2 x 22.2 x 72.4 cm) (6.80 kg)

D0805 240 VAC 38 liters/hour 6" x 8.75" x 28.5" 15 lbs.

(15.2 x 22.2 x 72.4 cm) (6.80 kg)

Cartridges are sold separately.

Low costIdeal forsmall volumeapplications

Lowest costDesignedfor non pressuredapplications

• Adjustable feed and reject valving• Ideal for small volume applications• A non-pressure deionizer cannot

accept back pressure• Minimum inlet pressure 5 psi;

maximum inlet pressure 70 psi

A P P L I C A T I O N• Point of use polishing of pretreated

water or single stage treatment oftap water.

Hose Nipple Cartridge shown in optional holder

Bantam Deionizer

CATALOG3NEW 3/17/98 2:18 PM Page 190

Page 22: PRODUCT SELECTION GUIDE - Cole-Parmer · PRODUCT SELECTION GUIDE Barnstead I Thermolyne 165 800-553-0039 Ultraviolet Oxidation/Ultrafiltration (UV/UF) Water Systems Description Applications

191 800-553-0039Barnstead I Thermolyne

Cartridge Kits for NANOpure® Infinity, NANOpure® , NANOpure II®, E-pure™ Ultrapure Water Systems.Barnstead ultrapure water systems require expendable cartridges and filters not supplied with the unit. Cartridge kits include everythingneeded to allow the Barnstead ultrapure water systems to supply 18.3 megohm-cm resistivity Type I reagent grade water.

Cartridge Kits for QuadStyle NANOpure® Systems (Final Filters sold separately)Part No. Description Content Price

D4801 Type I Cartridge Kit; Tap Feed 1-D0835 Pretreatment Cartridge, 1-D0803 High Capacity Cartridge, 2-D5027 Ultrapure Cartridges

D4802 Type I ORGANICfree Cartridge Kit; Tap Feed 1-D0836 MACROpure Cartridge, 1-D0803 High Capacity Cartridge, 1-D5027 Ultrapure Cartridge, 1-D5021 ORGANICfree Cartridge

D5025 Type I Cartridge Kit; Pretreated Feed 1-D0835 Pretreatment Cartridge, 2-D5027 Ultrapure Cartridges, 1-D0809 Ultrapure Cartridge

D5026 Type I ORGANICfree Cartridge Kit; Pretreated Feed 1-D0836 MACROpure Cartridge, 1-D5027 Ultrapure Cartridges, 1-D5021, 1-D0809 Ultrapure Cartridge, ORGANICfree Cartridge

Cartridge Kits for E-pure™ Systems (Final Filters sold separately)Part No. Description Contents Price

D5029 3 Module Type I Cartridge Kit 1-D0835 Pretreatment Cartridge, 2-D5027 Ultrapure Cartridges

D5028 4 Module Type I Cartridge Kit 1-D0835 Pretreatment Cartridge, 1-D0803 High Capacity Cartridge, 2-D5027 Ultrapure Cartridges

D50227 4 Module Type I Cartridge Kit; 1-D0835 Pretreatment Cartridge, 2-D5027 Ultrapure Cartridges, 1-D0809 Ultrapure CartridgePretreated Feed

D5022 3 Module ORGANICfree 1-D0836 MACROpure Cartridge, 1-D5027 Ultrapure Cartridge, 1-D5021 ORGANICfree Cartridge, Type I Cartridge Kit

D5023 4 Module Type I Cartridge Kit 1-D0836 MACROpure Cartridge, 1-D0803 High Capacity Cartridge, 1-D5027 Ultrapure Cartridge, 1-D5021 ORGANICfree Cartridge

D50228 4 Module Type I Cartridge Kit; 1-D0836 MACROpure, 1-D5027 Ultrapure Cartridges, 1-D5021 ORGANICfree Cartridge Pretreated Feed 1-D0809 Ultrapure Cartridge

Cartridge Kits for NANOpure® and NANOpure II® Systems (Final Filters sold separately)Part No. Description Contents Price

D3805 3 Module Type I Cartridge Kit 1-D0835 Pretreatment Cartridge, 2-D0809 Ultrapure Cartridges

D3804 4 Module Type I Cartridge Kit 1-D0835 Pretreatment Cartridge, 1-D0803 High Capacity Cartridge, 2-D0809 Ultrapure Cartridges

D3806 3 Module ORGANICfree 1-D0836 MACROpure Cartridge, 1-D0809 Ultrapure Cartridge, 1-D0820 ORGANICfreeType I Cartridge Kit

D3807 4 Module ORGANICfree 1-D0836 MACROpure Cartridge, 1-D0803 High Capacity Cartridge, 1-D0809 Ultrapure Cartridge, Type I Cartridge Kit 1-D0820 ORGANICfree

Cartridge Kits for NANOpure Infinity™Part No. Description Contents Price

D50256 Type I Cartridge Kit TAP or DI Feed 1 -D50251 Pretreatment Cartridge, 3 -D50253 Ultrapure Cartridges, 2 -FL703X2 Final Filters

D50257 Type I Cartridge Kit RO or Dist. Feed 1 -D50250 Pretreatment Cartridge, 3 -D50253 Ultrapure Cartridges, 2 -FL703X2 Final Filters

D50254 ORGANICfree Cartridge Kit TAP or DI Feed 1 -D50251 Pretreatment Cartridge, 2 -D50253 Ultrapure Cartridges, 1 -D50252 ORGANICfree Cartridge,2-FL703X2 Final Filters

D50255 ORGANICfree Cartridge Kit RO or Dist. Feed 1-D50250 Pretreatment Cartridge, 2-D50253 Ultrapure Cartridges, 1-D50252 ORGANICfree Cartridge, 2-FL703X2 Final Filters

C A R T R I D G E K I T S

D e i o n i z a t i o n

Cartridges

CATALOG3NEW 3/17/98 2:18 PM Page 191