Unit 21, Highview, High Street, Bordon, Hampshire. GU35 0AX. Tel: +44 (0)1420 487788 Fax: +44 (0)1420 487799 Email: [email protected] www.axio.co.uk © Copyright Axio 2004. All Rights Reserved AX-AV-EP - Issue 1.0 - Date 23/8/2006 AX-AV-EP Air Flow Probe- ABS Page 1 of 3 Product Overview The AX-AV-EP series of air differential pressure probes for small ducts. They are manufactured from ABS and come complete with a gasket. The units are designed to work with a differential pressure transmitter such as the AX-ADPT-LP2A range Complete with flanges and gasket designed to operate with AX-ADPT range of air velocity transmitters Features: ABS 10 sizes from 100 to 600mm sizes as standard Product Specifications: Materials: ABS Mounting: Integral flange with gasket Connections: 1/4” nipples for 3/8” OD polythese tubing Ambient Range: 0 to 50deg C Country of Origin: Canada Order Codes: AX-AV-EP-100 Air Velocity Probe 102mm AX-AV-EP-150 Air Velocity Probe 152mm AX-AV-EP-200 Air Velocity Probe 203mm AX-AV-EP-250 Air Velocity Probe 254mm AX-AV-EP-300 Air Velocity Probe 305mm AX-AV-EP-350 Air Velocity Probe 355mm AX-AV-EP-400 Air Velocity Probe 406mm AX-AV-EP-450 Air Velocity Probe 456mm AX-AV-EP-500 Air Velocity Probe 506mm Dimensions:

Transcript of Product Overview - Heat & Combustion products/product 11/3.AX-AV-EP.pdf · Product Overview The...

Unit 21, Highview, High Street, Bordon, Hampshire. GU35 0AX.Tel: +44 (0)1420 487788 Fax: +44 (0)1420 487799

Email: [email protected]

www.axio.co.uk

© Copyright Axio 2004. All Rights Reserved

AX-AV-EP - Issue 1.0 - Date 23/8/2006

AX-AV-EPAir Flow Probe- ABS

Page 1 of 3

Product Overview

The AX-AV-EP series of air differential pressure probes

for small ducts. They are manufactured from ABS and

come complete with a gasket. The units are designed to

work with a differential pressure transmitter such as the

AX-ADPT-LP2A range

• Complete with flanges and gasket

• designed to operate with AX-ADPT range of air

velocity transmitters

Features:

• ABS

• 10 sizes from 100 to 600mm sizes as standard

Product Specifications:

Materials: ABS

Mounting: Integral flange with gasket

Connections: 1/4” nipples for 3/8” OD polythese tubing

Ambient Range: 0 to 50deg C

Country of Origin: Canada

Order Codes:

AX-AV-EP-100 Air Velocity Probe 102mm

AX-AV-EP-150 Air Velocity Probe 152mm

AX-AV-EP-200 Air Velocity Probe 203mm

AX-AV-EP-250 Air Velocity Probe 254mm

AX-AV-EP-300 Air Velocity Probe 305mm

AX-AV-EP-350 Air Velocity Probe 355mm

AX-AV-EP-400 Air Velocity Probe 406mm

AX-AV-EP-450 Air Velocity Probe 456mm

AX-AV-EP-500 Air Velocity Probe 506mm

Dimensions:

Unit 21, Highview, High Street, Bordon, Hampshire. GU35 0AX.Tel: +44 (0)1420 487788 Fax: +44 (0)1420 487799

Email: [email protected]

www.axio.co.uk

© Copyright Axio 2004. All Rights Reserved

AX-AV-EP - Issue 1.0 - Date 23/8/2006

AX-AV-EPAir Flow Probe- ABS

Page 2 of 3

Every effort has been taken in the production of this data sheet to ensure it’s accuracy. Axio can not, however, accept responsibility for any damage, expense, injury, loss or consequential loss

resulting from any errors or omissions. Axio has a policy of continuous improvement and reserves the right to change this specification without notice.

InstallationMount the air velocity probe in the duct.

Adjust the speed of the fan to give a known air velocity. turn the static pressure probe so that a differential pressure

corresponding to the to the known air velocity is measured across the two probes. Lock in position using the pan-head

screws on the flanges

If the fan speed adjustment is not possible measure the air velocity with an anemometer or similar carry out procedure as

above.

Calculation

The air velocity probes can be connected to an Air differential pressure transmitter as per the above drawing

to select the correct range of AX-ADPT see the table on page 3

The output of the Air diferential pressure represents the air velocity and is defined by the following equation:-

Velocity squared = 2 x Velocity pressure

------------------------------

1.2

This calculation should be performed in a controllers stategy to air velocity in m/sec

Unit 21, Highview, High Street, Bordon, Hampshire. GU35 0AX.Tel: +44 (0)1420 487788 Fax: +44 (0)1420 487799

Email: [email protected]

www.axio.co.uk

© Copyright Axio 2004. All Rights Reserved

AX-AV-EP - Issue 1.0 - Date 23/8/2006

AX-AV-EPAir Flow Probe- ABS

How to use the Air velocity v differential pressure chart

Take the Left hand column take the relevant velocity in m/sec

then move along the top column to the relvant velocity in 0.1m/sec

Read the diferential pressure required in pascals

size the AX-ADPT to the next size above the the pascal range