PRODUCT INTRODUCTIONInternational Electric
Asea E&TJungwon Electric Systms
Jinkwang E&C
2
PRODUCT INTRODUCTION
Prod
uct I
ntro
duct
ion
Chairman Kim, Bong Hyun
International Electric Co., Ltd. was founded in 1946 and celebrates its 69th corporate anniversary this
year. After developing its first traction transformer in 1979, the company has had an unrivaled advance
in the field of special transformers for trains and has also increased its domestic market share in the
heavy electric machinery field. Not satisfied, however, the company is making efforts to jump into
overseas exports. After acquiring Jin Kwang E&C Co. Ltd. in 2014, 4 companies including ASEA E&T Co.,
Ltd., Jungwon Electric Systems Inc., and International Electric Co., Ltd. have become one family.
Through the acquisition of related companies, it is strengthening not only the field of special trans-
formers, but also other electronic fields such as switches, UPS, inverters, rectifiers, and battery chargers.
As it entered a technology introduction contract with the American firm Emerson in 1984 and became
designated as a systematized enterprise specializing in power plants by the government, it has made
efforts for exportation by obtaining PS and UL marks while bringing in various technologies such as
high pressure generators for electric precipitators, Thyristor digital control method, and high voltage
power source for electric precipitators through a technology agreement with Origin Electric in the 90s.
With the establishment of an enterprise annex research institute in 1994 as a foundation, the company
was designated as a ‘Q-Class’ nuclear power plant firm and grew as a core enterprise of the national
power industry. Also, the company arranged production facilities for molded transformers and started
sales in 2009. It endlessly seeks change and challenges as a transformer manufacturer.
We intend to promote the main products of International Electric and its affiliates through this product
introduction catalogue.
Thank you.
CEO Message
3Pr
oduc
t Int
rodu
ctio
n
Contents
Power Transformers
Power Equipments
Power Electronics
Contact Information
04
09
13
23
Power Transformer, Cast Resin Transformer, Distribution Transformer, Pole Mounted Transformer, PAD Transformer, Main Transformer for Electromotive Car, Dry Type Transformer / Reactor for SIV, Dry Type Neutral Grounding Reactor, Dry Type Transformer (UPS, B/CH, AVR)
Induction Voltage Regulator (IVR), Automatic Step Voltage Regulator (SVR), Gas Insulated Vacuum Recloser, Pole Mounted Epoxy-molded Vacuum Recloser, Gas Insulated Sectionalizer
Uninterruptible Power System (UPS), Automatic Voltage Regulator (AVR), High Voltage Generator for Electrostatic Precipitator (EP), Battery Charger, Inverter, Rectifier (Dry and Oil Type)
International Electric Co., Ltd.Asea E&TJungwon Electric Systems Inc.Jinkwang E&C Corporation
PRODUCT INTRODUCTION
4
PRODUCT INTRODUCTION
Prod
uct I
ntro
duct
ion
PRODUCT INTRODUCTION
Power Transformer
Cast Resin Transformer
Constant : Single-phase, Three-phaseFrequency : 50, 60HzCapacity : 60MVA or lowerVoltage : 69KV or lower
Constant : Single-phase, Three-phaseFrequency : 50, 60HzCapacity : 10MVA or lowerVoltage : 36KV or lower
Since epoxy resin is molded in vacuum state, it is very resistant tohumidity and environment-friendly. In addition, it uses specially treated glass for excellent mechanical strength.
It maintains optimal state of insulation thanks to the coil surfacetreated with special finishing work.
Since it is of superior self-extinguishability, there is no risk of fire conduction and poisonous gas during combustion. Its partial discharging value is low due to the latest vacuum casting technology applied (lower than 10pC)
Power transformer is a device to transmit power from power plant to substation. It is widely used in industrial faculties such as substations and factory.
It is manufactured in accordance with international standard and KS Standards. We customize our design of power transformerto customer’s specifications to meet their satisfaction.
Power Transformers
5Pr
oduc
t Int
rodu
ctio
n
Pole Mounted Transformer
Constant : Single-phaseCapacity : 10 - 150KVA Voltage : 36KV or lower Frequency : 50, 60HzType : Oil, Amorphous Core
Pole transformer is installed in the distribution lines of KEPCO. It is usually installed on electric poles to lower high voltage.
Distribution Transformer
Constant : Single-phase, Three-phaseFrequency : 50, 60HzCapacity : 30MVA or lowerVoltage : 69KV or lower
Distribution transformer functions to receive high voltage fromdistribution lines and supply necessary voltage to users.
It is divided into indoor and outdoor distribution transformer. We customize production to customers’ order and needs.
6
PRODUCT INTRODUCTION
Prod
uct I
ntro
duct
ion
PurposeIt is a dry type transformer installed in power supply unit for UPS
SpecificationsRated Capacity : 150KVA – 1,000KVAInput/Output Voltage : 220 - 480AC / 216 - 540VACInsulating Class : B, F, H ClassFrequency : 50, 60Hz
Characteristics- Environment-friendly (highly efficient, small in size, light and low noise)- Long life cycle and solid structure Major ClientKEPCO, KHNP, Thermal Power Plant, etc.
Dry Type Transformer for UPS, B/CH, AVR
PRODUCT INTRODUCTION
Power Transformers
Constant : Single-phase, Three-phaseFrequency : 50, 60HzCapacity : Less than 3000KVAVoltage : Less than 36KV
On-ground transformer is designed for underground distribution facility, streetlights, place adjacent to residential area, school, building, hospital and factory. It is possible to install it near downtown load area. Since it is equipped with protection fuse and fault current limiting fuse, it can prevent damage to transformer and error expansion in case of error in transformer. External power connection unit is designed to be completely insulated. It has radian and loop type transformer. In addition, it can be structured in both open and close type.
PAD Transformer
7Pr
oduc
t Int
rodu
ctio
n
PurposeIt receives AC 25K high voltage current from wire (Catenary), changes it to necessary voltage and transmits power to main electric motor through main power converter at secondary (conventional) side or to auxiliary circuit through auxiliary power supply system at the third (tertiary) side.
Specifications1) Rated Capacity : 20KVA – 8900KVA2) Input/Output Voltage : 25000V-840-1548V-221V/25000V-840V-929V AC3) Constant : Single-phase, Three-phase4) Frequency : 50, 60Hz Capacity : Less than 3000KVA Voltage : Less than 36KV
CharacteristicsOur company produced transformer for railway vehicle first in Korea and is currently developing next-generation train main transformer,emerging as market reader in the domestic market.
Major ClientKorea Railroad Corporation, Hyundai Rotem and others.
Main Transformer for Electromotive Car
8
PRODUCT INTRODUCTION
Prod
uct I
ntro
duct
ion
PRODUCT INTRODUCTION
PurposeNGR is a reactor to limit ground fault current at secondary neutron point of power transformer. 3Ø 45/60MVA 154KV/22.9KV, KEPCOApplied standard : IEC60289, IEC60076-11
StandardsReactance : 0.6Ω(60Hz)Continuous current : 300AShort Time Current : 10,000A/10 sec.Insulating Class : H Class (dry type)Peripheral Temperature : -25℃ - 40℃
Characteristics- Independent air core structure supported with base insulator on ground- Strong enough to resist to electron mechanical power in case that current flows in- Highly efficient ventilation structure
PurposeIt is a dry type transformer installed in the auxiliary power supply(APS) of railway vehicle. It adopts APS circuit system : 2 level-voltage type PWM inverter.
Specifications1) Rated Capacity : 125KVA – 160KVA2) Input/Output Voltage : 100-700V/40-100 AC3) Frequency : 50, 60Hz
Characteristics- Environment-friendly (highly efficient, small in size, light and low noise)- Degree of waterproof level: IPX5
Major ClientMELCO (Mitsubishi, Japan), Woojin Industrial Systems Co. and others
Dry Type Transformer/Reactor for SIV
Dry Type Neutral Grounding Reactor
Power Transformers
9Pr
oduc
t Int
rodu
ctio
n
PRODUCT INTRODUCTION
Power Equipments
Induction Voltage Regulator (IVR)
high voltage IVR low voltage IVR
Purpose
Standards
Characteristics
Instrument for various electric testsVariable regulator for industrial voltage and current Industrial machinery and tools and system necessary for various uninterrupted voltage
Type : motor driven voltage stabilizerPhase No : Three-phase and three-wire, Single-phaseFrequency : 50, 60Hz Capacity : 10KVA – 2000KVA (self-cooled type: CNAN)Voltage : 220VAC – 13,200VACControl Range : Out Voltage +/-10% - +/- 100%Efficiency : Above 95%Ambient Temperature : -20℃ - +40℃
On-load Stepless Voltage VariationUsing high-magnetic-inductivity silicon steelMicroprocessor-controlledRemote monitoring function via RS232,485,422
10
PRODUCT INTRODUCTION
Prod
uct I
ntro
duct
ion
PRODUCT INTRODUCTION
Automatic Step Voltage Regulator (SVR)
Power Equipments
PurposeBased on our long-cumulated know-how and experience, PVRis the product that we succeeded in developing first in Koreaunder technology introduction contract with U.S. Cooper Power System.
SpecificationsConstant : Single-phaseVoltage : 11, 22, 33KV±10%Current : Up to 640ABIL : 95, 150, 200Frequency : 50, 60Hz Tank Type : Round, SquareTap Changer : 32 Steps
CharacteristicsThis regulator maintains phase-to-phase voltage within a certainrange and helps motor, lights and machine run properly.
Picture of Installation Case(PVR 7000KVA)
11Pr
oduc
t Int
rodu
ctio
n
Gas Insulated Vacuum Recloser
Pole Mounted Epoxy-Molded Vacuum Recloser
TypeRated voltage(kV)Rated current(A)Rated power frequency withstand voltage(kV)Rated lightning impulse withstand voltage(kV)Rated short-time current(kA, RMS)Rated symmetrical interrupting current(kA, RMS)Rated short circuit making current(kA, peak)
Minimum operating current(A)
Operating MechanismMechanical endurance(times)Weight(kg)Applied Standard
TypeRated voltage(kV)Rated current(A)Rated power frequency withstand voltage(kV)Rated lightning impulse withstand voltage(kV)Rated short-time current(kA, RMS)Rated symmetrical interrupting current(kA, RMS)Rated short circuit making current(kA, peak)
Minimum operating current(A)
Operating MechanismMechanical endurance(times)Weight(kg)Applied Standard
SF6 Gas Insulated Vacuum Recloser
Pole Mounted Epoxy-Molded Vacuum Recloser
JK - REC24(25.8)
630
60
150
12.5/16
12.5/16
32.5/42
10(2) - 900(step: 1A)
5(2) - 900(step: 1A)
Magnetic actuator
10,000
190
ANSI C37.60
JK - MREC24(25.8)
630
60
150
12.5/16
12.5/16
32.5/42
10(2) - 900(step: 1A)
5(2) - 900(step: 1A)
Magnetic actuator
10,000
190
ANSI C37.60
12(15)
630
50
110
160
36(38)
630 / 800
70
170
280
36(38)
630 / 800
70
170
250
PhaseGround
PhaseGround
12(15)
630
50
110
160
12
PRODUCT INTRODUCTION
Prod
uct I
ntro
duct
ion
PRODUCT INTRODUCTION
Gas Insulated SectionalizerSF6 Gas Insulated Sectionalizer
Power Equipments
1s
10s
Phase
Ground
TypeRated voltage(kV)Rated current(A)Rated power frequency withstand voltage(kV)Rated lightning impulse withstand voltage(kV)Rated short circuit making current(kA, peak)
Rated short-time current(kA, RMS)
Minimum actuating current(A)
Inrush restraint multiplierMechanical endurance(times)Weight(kg)Applied Standard
JK - GACSBS24(25.8)
200 / 400 / 630
60
150
25 / 32.5
10 / 12.5
3.5
16, 24, 40, 56, 80, 112, 160, 224, 256,
300, 448, 640, Bypass
3.5, 7, 18, 28, 40, 56, 80, 112, 160,
224, 320, Block
1, 2, 4, 6, 8, Block
5,000
200
ANSI C37.63 / IEC 60265-1 / IEC 60694
12(15)
50
110
180
36(38)
70
170
220
13Pr
oduc
t Int
rodu
ctio
n
Uninterruptible Power System (UPS)
N+1 parallel operation Online double conversion DSP controlInput THDi: <3%Voltage options of storage battery: 16/19/20PCSLoad power factor: 0.9PFInput voltage tolerance range: 120 - 276VacInput frequency tolerance range: 54 - 66HzEnergy-saving ECO modeSelf-monitoring USP startAngular interface (SNMP, Relay Card, Parallel Card
Relay Card
(SNMP)
Parallel Card
Battery Cabinets (Optional)Control Panel Rear Side
ESCORT-2600 Series10 - 20kVA
3:1phase PF:0.9
ESCORT-1600 Series6 - 10kVA
1:1phase PF:0.9
PRODUCT INTRODUCTION
Power Electronics
Characteristics
14
PRODUCT INTRODUCTION
Prod
uct I
ntro
duct
ion
PRODUCT INTRODUCTION
Power Electronics
E1600_6kVA(S) E1600_6kVA(H)6k / 5.4k
220/230/240Vac120~276Vac
50Hz:45~55Hz;60Hz:54~66Hz(auto sensing)>0.99
Max.voltage:220V:+25%(optional+10%,+15%,+20%)230V:+20%(optional+10%,+15%)
240V:+15%(optional+10%)Min.voltage:-45%(optional -20%,-30%)
Same as the bypass<3%(100% Linear load)
Support
220/230/240Vac0.9
±1%±1%/±2%/±4%/±5%/±10% of the rated frequency(optional)
50/60(±0.1)Hz3:1
<2% with Linear Load , <5% with non-linear load>93.5%
±96/108/120Vdc (optional)6~8 hours(to 90% of full capacity)
1A(Standard unit);Long run unit Max.current 10A(charge current can be set according to battery capacity installed)
Mains to Battery:0ms;Mains to Bypass:0msLoad<110%:last 60min, <125%:last 10min,<150%:last 1min, >150% turn to bypass mode immediately
Hold Whole SystemLine Mode: Turn to Bypass; Backup Mode: Shut down UPS immediately
Alarm and Switch offUpon Power On and Software Control
Advanced Battery ManagementLine Failure, Battery Low, Overload, System Fault
Line Mode, Bat. Mode, Eco Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS FaultInput Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage,
Inner Temperature & Remaining Battery Backup TimeDry contact, USB, SNMP card(optional), Parallel card(optional), Relay card(optional)
0℃~40℃-25℃~55℃
0~95%(non-condensing)<1500m<55dB
502×250×616
IEC/EN62040-1, IEC/EN60950-1IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
MP-BT Series2×20pcs/7Ah(9Ah)
597×250×616122/134
ModelCapacity (VA/Watts)INPUTNominal voltageOperating voltage rangeOperating frequency rangePower factor
ECO rangeHarmonic distortion(THDi)Generator inputOUT PUTRated voltagePower factorVoltage regulation
Crest factorHarmonic distortion(THD)EfficiencyBATTERYBattery voltageTypical recharge timeCharge currentSYSTEM FEATURESTransfer time
Short circuitOverheatLow battery voltageSelf-diagnosticsBatteryAudible&Visual alarmsLED&LCD DISPLAY
Communication interfaceENVIRONMENTALOperating temperatureStorage temperatureHumidity rangeAltitudeNoise levelPHYSICALDimension D×W×H(mm)Net weight (kg)STANDARDSSafetyEMCBATTERY BANKModelBattery type&max.quantityPHYSICAL OF BATTERY BANKDimensions D×W×H(mm)Net weight (kg)
10k / 9kE1600_10kVA(S) E1600_10kVA(H)
40A(Breaker)
62 / 18
Line ModeBat. Mode
Line ModeBypass Mode 60A(Breaker)
64 / 20
Technical Specifications
Bypass voltage range
Frequency
Overload
LCD display
Specifications are subject to change without prior notice.
15Pr
oduc
t Int
rodu
ctio
n
Technical Specifications
380/400/415Vac;(3Ph+N+PE)208~478Vac
50Hz:45~55Hz;60Hz:54~66Hz(auto sensing)>0.99
Max.voltage:220V:+25%(optional+10%,+15%,+20%)230V:+20%(optional+10%,+15%)
240V:+15%(optional+10%)Min.voltage:-45%(optional -20%,-30%)
Frequency protection range: ±10%Same as the bypass
<5%(100% Linear load)Support
220/230/240Vac0.9
±1%±1%/±2%/±4%/±5%/±10% of the rated frequency(optional)
50/60(±0.1)Hz3:1
<2% with Linear Load , <5% with non-linear load
±96/108/120Vdc (optional)12V/7Ah
6~8 hours(to 90% of full capacity)1A(10kVA Standard unit); Max.current 10A(Long run unit)
Mains to Battery:0ms;Mains to Bypass:0msLoad<110%:last 60min, <125%:last 10min,<150%:last 1min, >150% turn to bypass mode immediately
Hold Whole SystemLine Mode: Turn to Bypass; Bat. Mode: Shut down UPS immediately
Alarm and Switch offUpon Power On and Software Control
Advanced Battery ManagementLine Failure, Battery Low, Overload, System Fault
Line Mode, Bat. Mode, Eco Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS FaultInput Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage,
Inner Temperature & Remaining Battery Backup TimeDry contact, USB, SNMP card(optional), Parallel board(optional), Relay card(optional)
0℃~40℃-25℃~55℃
0~95%(non-condensing)<1500m
IEC/EN62040-1, IEC/EN60950-1IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
MP-BT Series2×20pcs/7Ah(9Ah)
597×250×616122/134
ModelCapacity (VA/Watts)INPUTNominal voltageOperating voltage rangeOperating frequency rangePower factor
Bypass frequency rangeECO rangeHarmonic distortion(THDi)Generator inputOUT PUTRated voltagePower factorVoltage regulation
Crest factorHarmonic distortion(THD)EfficiencyBATTERYBattery voltageCapacity (standard unit)Typical recharge timeCharge currentSYSTEM FEATURESTransfer time
Short circuitOverheatLow battery voltageSelf-diagnosticsBatteryAudible&Visual alarmsLED&LCD DISPLAY
Communication interfaceENVIRONMENTALOperating temperatureStorage temperatureHumidity rangeAltitudeNoise levelPHYSICALDimension D×W×H(mm)Net weight (kg)STANDARDSSafetyEMCBATTERY BANKModelBattery type&max.quantityPHYSICAL OF BATTERY BANKDimensions D×W×H(mm)Net weight (kg)
E2600_10kVA S/H10k / 9k
63A(Breaker)
E1600_15kVA15k / 13.5k
100A(Breaker)
E1600_20kVA20k / 18k
125A(Breaker)
>93.5%
Line ModeBat. Mode
Line ModeBypass Mode
>94.5%
<55dB
597×250×655(S)/502×250×616(H)76(S)/35(H)
<58dB
502×250×61645 46
Frequency
Overload
LCD display
Bypass voltage range
Specifications are subject to change without prior notice.
16
PRODUCT INTRODUCTION
Prod
uct I
ntro
duct
ion
PRODUCT INTRODUCTION
UPS Cabinet Control Panel Module Control Panel
Single module(3U)
6kVA/10kVA 1:1 phase6kVA/10kVA 3:1 phase
10kVA/15kVA/20kVA/25kVA/30kVA/40kVA 3:3 phase
3U Battery Box (Optional)
Uninterruptible Power System (UPS)
Online high frequency switching double conversionAdvanced PFC technology3U frame, lag-mounted typeEPO functionHigh input voltage toleranceDSP controlDistributed parallel controlABM functionProtection from thunderbolt, surge, cut circuit and overloadLCD and LED display in both Korean and EnglishEMI/RFI noise filterSupport RS232 and SNMP
Battery Cabinets(Optional)
ESCORT-3000 Series (6~1560kVA)E1160 / E1110
E3106 / E3110
E3310 / E3315 / E3320 / E3325 / E3330 / E3340 / E3352 / E3380 / E33104 / E33156
1 : 13 : 13 : 3
Power Electronics
Characteristics
17Pr
oduc
t Int
rodu
ctio
n
40~70Hz >0.99
Max.voltage:220V:+25%(optional+10%,+15%,+20%) 230V:+20%(optional+10%,+15%) 240V:+15%(optional+10%)Min.voltage:-45%(optional -20%,-30%)
Frequency protection range: ±10%
Support
±2%
1. Line Mode: ±1%, ±2%, ±4%, ±5%, ±10% of the rated frequency (optional) 2. Battery Mode: (50/60±0.1%)Hz
3:1<2% with linear Load, <5% with non-linear load
6A(Max.)(charge current can be set according to battery capacity installed)Depends on the capacity of external batteries
Utility to Battery: 0ms; Utility to bypass: 0msLoad<110%:last 60min, <125%:last 10min,<150%:last 1min, >150% shut down UPS immediately
Hold Whole SystemComplies with EN62040-2
1. UPS cabinet: RS232, RS485, Dry Contact, Intelligent slot ×2(SNMP card, Relay Card optional)2. UPS module: RS232
0℃~40℃-25℃~55℃
0~95%(non-condensing)<1500m
443×580×131 (3U)
IEC/EN62040-1, IEC/EN60950-1IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,
IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
Specifications are subject to change without prior notice.
220/230Vac120~276Vac
380/400/415Vac,(3Ph+N+PE)208~478Vac
380/400Vac(3Ph+N+PE) or 220/230Vac208~478Vac or 120VAC-276Vac
2%(100% nonlinear load)5%(100% non-linear load)
380/400/415Vac,(3Ph+N+PE)
0.9/1(Customized)
220/230Vac
0.8
6k / 4.8k, 10k / 8k 10k/9k,15k/13.5k,20k/18k
150138
30A(Max.) 60A(Max.)60A(Max.) 30A(Max.)
840×600×1400
138
840×600×2000
213
840×600×2000
150
840×600×1400 840×600×1400
170
1100×600×2000
270
Load<110%:last 30S,<125%:last 1S,<150%:last 200ms,>150% shut down UPS immediately
Breaker(6kVA:40A / 10kVA:60A)
Load<110%:last 10min, <125%:last 1min, <150%:last 1S,>150% shut
down UPS immediatelyBreaker(10kVA:20A/15kVA:32A/20
kVA:40A)
<55dB
6kVA/23kg; 10kVA/25kg
<65dB
10kVA/26;15kVA/30kg;20kVA/31kg
Technical Specifications
Model
INPUTRated VoltageInput Voltage Tolerances RangeInput Frequency Tolerances RangeInput Power Factor
Harmonic distortion(THDi)Generator inputOUT PUTOutput voltageVoltage regulationPower factor
Crest factorHarmonic distortion(THD)EfficiencyBATTERY
Battery voltage
Charge currentBackup timeSYSTEM FEATURESTransfer time
Short circuitNose suppression
ENVIRONMENTALOperating temperatureStorage temperatureHumidity rangeAltitudeNoise levelPHYSICALDimension D×W×H(mm)Net weight(kg)STANDARDSSafety
EMC
UPS CabinetModule
UPS CabinetModule
UPS cabinetHPM moduleUPS cabinetHPM module
Line Mode
E1100-30K6~30k/4.8~24k
E3100-50K6~50k/4.8~40k
E1100-50K6~50k/4.8~40k
E3100-100K6~100k/4.8~80k
E3100-30K6~30k/4.8~24k
E3300-100K10~100k/9~90k
E3300-200K10~200k/9~180k
93.5%
±96\±108\±120Vac;Battery quantity(optional)
95.5%
±192\±204\±216\±228\±240Vdc; battery quantity(optional)
30A(Max.) 60A(Max.)
Capacity(VA/Watts)
Bypass Voltage Tolerances Range
Output frequency
Overload
Communication interface
Bat. Mode
Bypass Mode
18
PRODUCT INTRODUCTION
Prod
uct I
ntro
duct
ion
PRODUCT INTRODUCTION
Power Electronics
Technical Specifications
380/400/415Vac,(3Ph+N+PE)208~478Vac
40~70Hz>0.99
Max.voltage:220V:+25%(optional+10%,+15%,+20%) 230V:+20%(optional+10%,+15%) 240V:+15%(optional+10%)Min.voltage:-45%(optional -20%,-30%)
Frequency protection range: ±10%3%(100% non-linear load)
Support
380/400/415Vac,(3Ph+N+PE)±1%0.9
1. Line Mode: ±1%, ±2%, ±4%, ±5%, ±10% of the rated frequency (optional)2. Battery Mode: (50/60±0.1%)Hz
3:1<2% with linear Load, <5% with non-linear load
95.0%
±192\±204\±216\±228\±240Vdc; battery quantity(optional)
Depends on the capacity of external batteries
Utility to Battery: 0ms; Utility to bypass: 0msLoad<110%:last 60min, <125%:last 10min,<150%:last 1min, >150% shut down UPS immediately
Hold Whole SystemComplies with EN62040-2
1. UPS cabinet: RS232, RS485, Dry Contact, Intelligent slot ×2(SNMP card, Relay Card optional)2. UPS module: RS232
0℃~40℃-25℃~55℃
0~95%(non-condensing)<1500m
443×580×131 (3U)
IEC/EN62040-1, IEC/EN60950-1IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,
IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
E3300-520K520k/468k
E3300-250K250k/225k25k/22.5k
E3300-300K300k/270k
30k/27k
E3300-800K800k/720k
E3300-400K400k/360k
E3300-1040K1040k/936k
E3300-1560K1560k/1404k
40k/36k
UPS CabinetModule
200A(Max.)60A(Max.)6A(Max.)
100A(Max.) 260A(Max.)130A(Max.) 390A(Max.)10A(Max.)
Specifications are subject to change without prior notice.
29032
31033
750 1600860 1810 2800
<70dB
600×1100×2000W D H W D H W D H W D H
1200×860×2000 3000×860×2000 4800×1100×2000
<73dB
35
Load<110%:last 30S,<125%:last 1S,<150%:last 200ms,>150% shut down UPS immediately
Load<110%:last 10min, <125%:last 1min, <150%:last 1S,>150% shut
down UPS immediately
UPS cabinetModuleUPS cabinetModule
Line Mode
Bat. Mode
Bypass Mode 40A 63A 100A
UPS CabinetModule
Overload
Communication interface
EMC
Output frequency
Bypass Voltage Tolerances Range
Capacity(VA/Watts)
Model
INPUTRated VoltageInput Voltage Tolerances RangeInput Frequency Tolerances RangeInput Power Factor
Harmonic distortion(THDi)Generator inputOUT PUTOutput voltageVoltage regulationPower factor
Crest factorHarmonic distortion(THD)EfficiencyBATTERYBattery voltageCharge currentBackup timeSYSTEM FEATURESTransfer time
Short circuitNose suppression
ENVIRONMENTALOperating temperatureStorage temperatureHumidity rangeAltitudeNoise levelPHYSICALDimension D×W×H(mm)Net weight(kg)STANDARDSSafety
19Pr
oduc
t Int
rodu
ctio
n
Highlights:100 kW rated power module500 kW rated power in single frameExtended power range: from 100 kW to 3MWUnity output power factor (kVA = kW)AC-AC efficiency up to 96 %Efficiency in eco-mode ≥ 99 %Online Swap Modularity (OSM)Online serviceabilityTop or bottom cable entry (standard)Built-in back-feed protection (standard)Graphical display on system levelDPA displays in each moduleMaintenance bypass switch (optional)
True Modularity up to 3MWNow you can have a UPS size to exactly fit your needs: The Concept-power DPA 500 is the only modular UPS on the market that can easily be scaled up to provide 3MW of clean, reliable power.
True Parallel ArchitectureReliability and availability are ensured by the Conceptpower DPA 500’s proven Decentralised Parallel Architecture (DPATM). Each module contains all the hardware and software required for full system operation. They share no common components. Each UPS module has its own independent static bypass, rectifier, inverter, logic control, control panel, battery charger and batteries. With all the critical components duplicated and distributed between individual units, potential single points of failure are eliminated.
Vertical scalability: one to five modules in one single cabinet
Horizontal scalability: cabinets in parallel configuration up to 3MW
ABB’s Conceptpower DPA 500 The UPS for those who need zero downtime
Online-swappable modules
Top cable entry
Bottomcable entry
Smartconnectioninterface
Inbuiltmaintenancebypass switch
Scalable up to 3MW
20
PRODUCT INTRODUCTION
Prod
uct I
ntro
duct
ion
PRODUCT INTRODUCTION
Power Electronics
Technical Specifications
21Pr
oduc
t Int
rodu
ctio
n
High Voltage Generator for Electrostatic Precipitator (EP)Constant : Single-phaseRectifying Method : Single-phase wave rectifying methodInput Voltage : 220 – 480VControl Power : 110VACOutput Voltage : DC30KV – 120KV / 100-2000mA
Automatic Voltage Regulator (AVR)
Constant : Single-phase, Three-phaseFrequency : 50, 60Hz Voltage - Input : 110VAC - 480VAC±15%- Output : 110VAC - 480VAC±2%Capacity : 500KVA max.
It adopts tap changing regulator that has less wave distortion than existing CVT that uses the magnetic saturation and resonance phenomenon ofmetal pin. It can maintain stable output voltage due to high-speed switching.
Low noise and light weight
Quicker response than existing CVT method in terms of load and inputchange
Major ClientNuclear plant (“Q”, “T”, “R” Class), KEPCO, Thermal Plant, etc.
High voltage generator for electrostatic precipitator (EP) consists of transformer for outdoor rectifier (T/R) and indoor control panel. Transformer for outdoor rectifier supplies high DC voltage and current necessary for electric precipitation. The output voltage of T/R should remain close to ignition point for effective work of electric precipitation.T/R consists of transformer, current limiting reactor and rectifier that is formed by single-phase half wave rectification, including high-speed switching. The parts embedded in oil tank should be completely sealed and painted for outdoor purpose. Control panel contains thyristor elements and all the electric parts necessary to protect and monitor high power units.
Major ClientThermal Power Plant, Chemical Power Plant, District Heating Corp., etc.
22
PRODUCT INTRODUCTION
Prod
uct I
ntro
duct
ion
PRODUCT INTRODUCTION
Power Electronics
Rectifier (Dry and Oil Type)
Composed of diode, SCR and IGBT rectifier element, rectifier receives single-phase or three-phase power and yields direct current. It is being more and more used in special power facility and safety power facility as industrial facility gets more precise and automated.
Major ClientNuclear Plant (“Q”, “T”, “R” Class), Thermal Plant, Chemical Plant, Iron and Steel Plant, etc.
Inverter
Battery Charger
Constant : Single-phaseFrequency : 50, 60Hz Voltage - Input : 120 - 480VAC- Output : 120 - 480VAC
Capacity : 20 - 2000A
Constant : Single-phase, Three-phaseFrequency : 50, 60HzVoltage - Input : 110 - 480VAC- Output : 24 - 200VDC
Capacity : 10 - 20000A
Voltage - Input : 125 - 600VDC- Output : 120 - 480VAC, 50, 60Hz
Capacity : 5 - 400KVA
Major ClientNuclear Plant (“Q”, “T”, “R” Class), Thermal Plant, Chemical Plant, Iron and Steel Plant, etc.
Composed of diode, SCR and IGBT rectifier element, recharger receives Single-phase or three-phase power and yields direct current. It is be-ing more and more used in special power facility and safety power facility as industrial facility gets more precise and automated.
Major ClientNuclear Plant (“Q”, “T”, “R” Class), Thermal Plant, Chemical Plant, Iron and Steel Plant, etc.
23Pr
oduc
t Int
rodu
ctio
n
PRODUCT INTRODUCTION
To learn more about our products or to request for a quotation, please visit below websites or send us an e-mail.Thank you.
International Electric Co., Ltd. Main Office and Factory98, Shinkyechun-ro, Kumwang-up, Unsaung-kun, Northern Chungcheong Province, South KoreaTEL +82-43-883-7751 FAX +82-43-883-7773Sales Division3F Iksung Building, 6 Bongeunsa-ro 112-gil, Gangnam-ku, Seoul, KoreaTEL +822-465-7751 FAX +822-465-4809EMAIL [email protected] www.ieckr.com
Asea E&T Main Office and Factory261 Kobul-ro, Kwangju City, Kyunggi Province, South KoreaTEL +82-31-797-7677 FAX +82-31-797-7477EMAIL [email protected] www.aseaent.co.kr
Jungwon Electric Systems Inc. Main Office and Factory91, 101 rd, Kyungchungdae-ro, Konjiam-up, Kwangju City, Kyunggi Province, South KoreaTEL +82-31-767-2845 FAX +82-31-767-2847EMAIL [email protected] http://jungwonco.com
Jinkwang E&C CorporationMain Office and Factory705, Buk-ri, Namsa-myun, Churin-gu, Youngin City, Kyunggi Province, South KoreaTEL +82-31-333-3444 FAX +82-31-332-5300 / 5301WEBSITE www.jinkwang.co.kr
Contact Information
24
PRODUCT INTRODUCTION
Prod
uct I
ntro
duct
ion
Asea E&T Main Office and Factory261 Kobul-ro, Kwangju City, Kyunggi Province, South KoreaTEL +82-31-797-7677 FAX +82-31-797-7477EMAIL [email protected] www.aseaent.co.kr
Jungwon Electric Systems Inc. Main Office and Factory91, 101 rd, Kyungchungdae-ro, Konjiam-up, Kwangju City, Kyunggi Province, South KoreaTEL +82-31-767-2845 FAX +82-31-767-2847EMAIL [email protected] http://jungwonco.com
Jinkwang E&C CorporationMain Office and Factory705, Buk-ri, Namsa-myun, Churin-gu, Youngin City, Kyunggi Province, South KoreaTEL +82-31-333-3444 FAX +82-31-332-5300 / 5301WEBSITE www.jinkwang.co.kr
International Electric Co., Ltd. Main Office and Factory98, Shinkyechun-ro, Kumwang-up, Unsaung-kun, Northern Chungcheong Province, South KoreaTEL +82-43-883-7751 FAX +82-43-883-7773Sales Division3F Iksung Building, 6 Bongeunsa-ro 112-gil, Gangnam-ku, Seoul, KoreaTEL +822-465-7751 FAX +822-465-4809EMAIL [email protected] www.ieckr.com