Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V...

24
Product information www.DrakaMOG.com Marine, Oil & Gas

Transcript of Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V...

Page 1: Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables ... BIOI 250 V (HUCOM

Product information

www.DrakaMOG.com

Marine, Oil & Gas

Page 2: Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables ... BIOI 250 V (HUCOM

DRAKA Product information MOG 2010

Page 3: Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables ... BIOI 250 V (HUCOM

For more than 100 years, Draka has met and exceeded challenging marine and offshore demands for electrical and data solutions. As a leading provider of cabling solutions, we are backed by quality manufacturing and local inventory in every key marine and offshore market. By focusing on customer needs, Draka employees deliver trusted, timely and dependable service for ships, oil rigs, subsea and offshore wind farms.

We take pleasure in presenting this catalog with our Shipboard cables.

The ShipLine Plus range is our standard range suitable for all ships including dredging vessels, marine vessels and FPSO’s.The cables have an innersheet and circular non-compacted conductors for increased flexibility and ease of installation.

For applications in less harsh environment like yachts and cruise vessels, we have the ShipLine range. This range is lighter and more compact.

For use in emergency systems where Fire Resistant cables (IEC 60331) is needed, we have our ShipLine FR cables available from stock.

In addition to these ranges we supply an extensive range of data cables, medium voltage cables, offshore cables and special cables.

You will find members of the Draka team working all around the globe, with strong presence in your home market. They represent literally hundreds of years of experience with product development, quality management and on-time project delivery. This unique expertise and understanding of the market enables Draka to provide you with the services you need to meet your toughest marine and offshore challenge.

Please visit www.DrakaMOG.com to learn more about what Draka can do to help you and for more the most recent information about our products.

Yours sincerely,

Draka

ShipLine Plus•halogen-free•internationalstandards•circularconductors•easytoinstall

ShipLine•halogen-free•internationalstandards•light-weight•cost-saving

ShipLine Fire Resistant•halogen-free•internationalstandards•fireresistant

Draka ShipLine range; the choice for reliability and flexibility

3DRAKA Product information MOG 2010

Page 4: Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables ... BIOI 250 V (HUCOM

Sheath colours

Power black

Instrument/signal grey

Fire resistant green

Standards applied

IEC 60092-3 Electrical installations in ships – Construction, testing and installation

IEC 60092-350 Low voltage shipboard power cables

IEC 60092-351 Insulating materials for shipboard power cables

IEC 60092-353 Single and multicore cables with extruded solid insulation for rated voltages 0.6/ 1 kV

IEC 60092-359 Sheating materials for shipboard power and telecommunication cables

IEC 60092-375 Shipboard telecommunication cables and radio frequency cables General instrumentation, control and communication cables

IEC 60092-376 Shipboard multicore cables for control circuits

IEC 60331 Tests for electric cables under fire conditions – Circuit integrity

IEC 60332-1 Tests on electric cables under fire conditions – Single vertical insulated wire or cable

IEC 60332-3A Tests on electric cables under fire conditions – Vertical flame spread of vertically mounted bunched wires and cables, category A

IEC 60754-1,2 Tests on gases evolved during combustion of materials from cables Determination of the amount of halogen acid gas Determination of degree of acidity by measuring Ph and conductivity

IEC 61034-1,2 Measurement of smoke density of cables burning under defined conditions Test apparatus, test procedures and requirements

Core identification

1 core black

2 cores blue – brown

3 cores brown – black – grey

4 cores blue - brown – black – grey

5 cores blue - brown – black – grey – black

6 cores and above white with black numbers

Earth core yellow/ green (optional)

Approvals

American Bureau of Shipping

Bureau Veritas

Det Norske Veritas

Germanischer Lloyd

Lloyd’s Register of Shipping

Certification by other classification bureaus at request.

4 DRAKA Product information MOG 2010

Page 5: Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables ... BIOI 250 V (HUCOM

For more information about these cables please visit www.DrakaMOG.com

Index

ShipLine Plus Page

TFXI 0.6/1 kV (HUSK) Power cable, unarmoured 6

TIOI 0.6/1 kV (HUSO) Power cable, armoured 8

TIOI (c) 250 V (HUCOM) Instrumentation cable, screened 11

ShipLine

TI 0.6/1 kV Power cable, unarmoured 12

TXOI 0.6/1 kV Power cable, armoured 14

TXOI 250 V Instrumentation cable, screened 16

ShipLine Fire Resistant

BI FR 0.6/1 kV Power cable, Fire Resistant, unarmoured 17

BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18

BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19

Data cables

Overview Data, FR, Video/Audio, CATV 20

Electrical characteristics of cables 21

Also available on request

Offshore cables

RFOU (NEK606) LV, MV, instrumentation (Mud resistant)

BFOU (NEK606) LV, MV, instrumentation (Fire/Mud resistant)

RFCU (UKOOA) LV, MV, instrumentation (Mud resistant)

BFCU (UKOOA) LV, MV, instrumentation (Fire/Mud resistant)

Type P (IEEE45) LV, MV, instrumentation (Mud resistant)

HXXM (IEEE45/IEC) LV, MV, instrumentation (Fire resistant)

Special cables

Flexible EMC Dredging cable 0,6/1 kV and 1,8/3,6 kV

NEK606 HCF 1100C

NEK606 Artic Grade (Cold bend/Cold impact)

TFOI 6/10 kV (also other Voltage rates on request)

Down hole Pump cable

VFD cables

Hulto EMC

ShipLine Plus Fire Resistant

BFXI 0.6/1 kV (HUSK FR) Power cable, Fire Resistant, not braided

BIOI 0.6/1 kV (HUSO FR) Power cable, Fire Resistant, braided

BIOI 250 V (HUCOM FR) Instrumentation cable, Fire resistant, braided

5DRAKA Product information MOG 2010

Page 6: Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables ... BIOI 250 V (HUCOM

TFXI 0.6/1 kV (HUSK)Halogen free shipboard and offshore cable

Application

Unarmoured power and control cable for fixed installations on ships

and offshore units where cable protection is not required.

Suitable for both indoor and outdoor installations.

Properties regarding fire performance

Halogen Free - According to IEC 60754-1,2

Low smoke - According to IEC 61034-1,2

Flame retardant - According to IEC 60332-3-22 (cat.A)

Design stadard: IEC 60092-353

Max. conductor temp.: 90°C*

Nominal voltage: 0.6/1 kV

Test voltage: 3.5 kV AC

Core identification

Single core Black

Two cores Blue - Brown

Three cores Brown - Black - Grey

Four cores Blue - Brown - Black - Grey

Five cores Blue - Brown - Black - Grey - Black

> 5 cores White with black numbers

With yellow/green:

Two cores + earth (3G) Yellow/green - Blue - Brown

Three cores + earth (4G) Yellow/green - Brown - Black - Grey

Four cores + earth (5G) Yellow/green - Blue - Brown - Black - Grey

> 4 cores + earth Yellow/green - White with black numbers

*Temporary overload permissible up to 130 °C

CODE LETTER

Conductor Annealed stranded circular copper

Insulation T Crosslinked polyethylene, XLPE

Bedding F Halogen free material

Armour/screen X No armouring

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

Outer sheath colour Black

Construction

Range, dimensions and technical data

product number

no. of cores and nominal cross- section (n x mm2)1

nominal conductor diameter (mm)

nominal core diameter (mm)

nominal outer diameter (mm)

approxi- mate weight (kg/km)

maximum current rating (A)2

conductor resistance at 20 °C DC (Ω/km)

conductor resistance at 90 °C, 60 Hz (Ω/km)

self in-ductance (mH/km)

working capaci-tance (nF/km)3

128624 1x10 3.9 5.3 7.3 125 88 1.83 2.33 - -

128625 1x16 5.0 6.4 8.4 185 119 1.15 1.47 - -

128626 1x25 6.3 8.1 10.3 290 158 0.727 0.927 - -

128627 1x35 7.5 9.3 11.5 375 197 0.524 0.669 - -

128628 1x50 8.7 10.7 13.1 500 239 0.387 0.494 - -

128629 1x70 10.5 12.7 15.3 705 307 0.268 0.343 - -

128630 1x95 12.4 14.6 17.2 950 374 0.193 0.248 - -

128631 1x120 14.0 16.4 19.2 1210 435 0.153 0.198 - -

128634 1x150 15.5 18.3 21.3 1490 502 0.124 0.161 - -

128632 1x185 17.4 20.6 23.6 1850 575 0.0991 0.130 - -

128633 1x240 19.9 23.3 26.5 2405 679 0.0754 0.101 - -

125130 2x1.5 1.6 3.0 8.6 110 23 12.1 15.4 0.33 59

125131 2x2.5 2.0 3.5 9.6 150 31 7.41 9.45 0.31 66

125132 2x4 2.5 4.0 10.7 195 43 4.61 5.88 0.29 73

125134 2x6 3.1 4.5 12.0 260 55 3.08 3.93 0.28 79

125144 2x10 3.9 5.4 13.7 375 75 1.83 2.33 0.26 86

125119 2x16 5.0 6.4 16.0 545 100 1.15 1.47 0.25 93

126442 3G1.5 1.6 3.0 9.2 130 23 12.1 15.4 0.33 59

126444 3G2.5 2.0 3.5 10.2 175 31 7.41 9.45 0.31 66

125104 3x1.5 1.6 3.0 9.2 130 20 12.1 15.4 0.33 118

125015 3x2.5 2.0 3.5 10.2 175 28 7.41 9.45 0.31 132

125105 3x4 2.5 4.0 11.3 235 37 4.61 5.88 0.29 146

6 DRAKA Product information MOG 2010

ShipLine Plus

Page 7: Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables ... BIOI 250 V (HUCOM

Range, dimensions and technical data

Installation recommendations

Minimum bending radius during installation

Minimum bending radius fixed installed

Maximum tensile load during installation

Minimum installation temperature

8 x D 6 x D 50 N * total cross section conductors -20 °C

TFXI 0.6/1 kV (HUSK)Halogen free shipboard and offshore cable

Other cross-sections and numbers of cores are available on request.

1 G = including green/yellow2 The current rating is based on an ambient temperature of 45 °C and a

maximum operating temperature of 90 °C, according to IEC 60092-

352 Table A.4:

I. For singel core cables, Method G: 3 cores spaced in free air

II. For multi-core cables, Method E: Multi-core cables in free air

- For 3G core cables, the values for 2 loaded cores are given.

- For 4 en 5 core cables, the values for 3 loaded cores are given.

Correction factors for different ambient temperatures are

given on page 21.3 Working capacitance for one-phase asymmetrical or three-phase

symmetrical system. The working capacitance of multicore types n>5

depends on the way the wires are connected.

product number

no. of cores and nominal cross- section (n x mm2)1

nominal conductor diameter (mm)

nominal core diameter (mm)

nominal outer diameter (mm)

approxi- mate weight (kg/km)

maximum current rating (A)2

conductor resistance at 20 °C DC (Ω/km)

conductor resistance at 90 °C, 60 Hz (Ω/km)

self in-ductance (mH/km)

working capaci-tance (nF/km)3

125106 3x6 3.1 4.5 12.7 315 47 3.08 3.93 0.28 158

125107 3x10 3.9 5.4 14.7 470 65 1.83 2.33 0.26 172

125109 3x16 5.0 6.4 17.0 680 87 1.15 1.47 0.25 186

125088 3x25 6.3 8.1 21.1 1060 110 0.727 0.927 0.25 199

125110 3x35 7.5 9.4 23.9 1390 137 0.524 0.669 0.24 208

125089 3x50 8.7 10.8 28.3 1925 167 0.387 0.494 0.24 218

124994 3x70 10.5 12.8 33.1 2710 214 0.268 0.343 0.23 228

125090 3x95 12.4 14.7 37.8 3670 259 0.193 0.248 0.22 237

125112 3x120 14.0 16.5 42.0 4600 301 0.153 0.198 0.22 244

125111 3x150 15.5 18.4 46.3 5625 347 0.124 0.161 0.22 250

126443 4G1.5 1.6 3.0 10.0 155 20 12.1 15.4 0.35 135

126445 4G2.5 2.0 3.5 11.1 205 28 7.41 9.45 0.33 150

126446 4G6 3.1 4.5 13.9 385 47 3.08 3.93 0.30 176

125135 4x1.5 1.6 3.0 10.0 155 20 12.1 15.4 0.35 135

125140 4x2.5 2.0 3.5 11.1 205 28 7.41 9.45 0.33 150

125141 4x4 2.5 4.0 12.6 290 37 4.61 5.88 0.31 164

125143 4x6 3.1 4.5 13.9 385 47 3.08 3.93 0.30 176

125145 4x10 3.9 5.4 16.1 580 65 1.83 2.33 0.29 192

125146 4x16 5.0 6.4 18.9 860 87 1.15 1.47 0.28 206

127385 5G1.5 1.6 3.0 10.9 185 20 12.1 15.4 - 140

127386 5G2.5 2.0 3.5 12.3 250 28 7.41 9.45 - 155

125441 5x1.5 1.6 3.0 10.9 185 20 12.1 15.4 - 140

125440 5x2.5 2.0 3.5 12.3 250 28 7.41 9.45 - 155

128639 6x1.5 1.6 3.0 11.4 175 15 12.1 15.4 - ≤155

128640 7x1.5 1.6 3.0 11.5 185 14 12.1 15.4 - ≤155

128647 8G1.5 1.6 3.0 12.7 220 14 12.1 15.4 - ≤155

128641 8x1.5 1.6 3.0 12.7 220 13 12.1 15.4 - ≤155

128642 10x1.5 1.6 3.0 14.6 265 12 12.1 15.4 - ≤155

128643 12x1.5 1.6 3.0 15.3 315 11 12.1 15.4 - ≤155

128644 16x1.5 1.6 3.0 17.0 400 10 12.1 15.4 - ≤155

128645 19x1.5 1.6 3.0 18.1 470 9 12.1 15.4 - ≤155

128646 24x1.5 1.6 3.0 21.3 620 8 12.1 15.4 - ≤155

7DRAKA Product information MOG 2010

ShipLine Plus

Page 8: Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables ... BIOI 250 V (HUCOM

TIOI 0.6/1 kV (HUSO)Armoured halogen free shipboard and offshore cable

Application

Armoured power-, control- and lighting cable for fixed installations

on ships and offshore units where cable protection is required.

Suitable for both indoor and outdoor installations.

Properties regarding fire performance

Halogen Free - According to IEC 60754-1,2

Low smoke - According to IEC 61034-1,2

Flame retardant - According to IEC 60332-3-22 (cat.A)

Design standard: IEC 60092-353

Max. conductor temp.: 90°C*

Nominal voltage: 0.6/1 kV

Test voltage: 3.5 kV AC

Core identification

Single core Black

Two cores Blue - Brown

Three cores Brown - Black - Grey

Four cores Blue - Brown - Black - Grey

Five cores Blue - Brown - Black - Grey - Black

> 5 cores White with black numbers

With yellow/green.

Two cores + earth (3G) Yellow/green - Blue - Brown

Three cores + earth (4G) Yellow/green - Brown - Black - Grey

Four cores + earth (5G) Yellow/green - Blue - Brown - Black - Grey

*Temporary overload permissible up to 130 °C

CODE LETTER

Conductor Annealed stranded circular copper

Insulation T Crosslinked polyethylene, XLPE

Inner sheath I Flame retardant halogen free thermoplastic compound, SHF1

Armour/screen O Tinned copper wire braiding

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

Outer sheath colour Black

Construction

Range, dimensions and technical data

pro

du

ct

nu

mber

no.

of

core

s an

d n

om

inal

cros

s-se

ctio

n

(n x

mm

2)1

nom

inal cr

oss-

sect

ion

al are

a

of t

he

eart

h

lead (

mm

2)

nom

inal

con

du

ctor

dia

met

er

(mm

)

nom

inal

core

dia

met

er

(mm

)

nom

inal

ou

ter

dia

met

er

(mm

)

appro

xim

ate

w

eight

(k

g/k

m)

maxim

um

cu

rren

t

rati

ng

(A)2

con

du

ctor

resi

stan

ce

at

20

°C

DC

/km

)

con

du

ctor

resi

stan

ce a

t 9

0 °

C, 6

0 H

z

(Ω/k

m)

self

in

du

ctan

ce

(mH

/km

)

work

ing

capaci

tan

ce

(nF/

km)3

125043 1x10 2.5 3.9 5.4 10.0 210 88 1.83 2.33 - -

125044 1x16 2.5 5.0 6.4 11.0 280 119 1.15 1.47 - -

125047 1x25 4 6.3 8.1 13.1 410 158 0.727 0.927 - -

125048 1x35 6 7.5 9.4 14.8 545 197 0.524 0.669 - -

125050 1x50 6 8.7 10.8 16.4 690 239 0.387 0.494 - -

125058 1x70 6 10.5 12.8 18.8 935 307 0.268 0.343 - -

125059 1x95 10 12.4 14.7 20.7 1205 374 0.193 0.248 - -

125051 1x120 10 14.0 16.5 22.9 1500 435 0.153 0.198 - -

125053 1x150 16 15.5 18.4 25.0 1810 502 0.124 0.162 - -

125055 1x185 16 17.4 20.7 27.6 2225 575 0.0991 0.131 - -

125056 1x240 16 19.9 23.4 30.5 2825 679 0.0754 0.102 - -

127296 1x300 25 22.3 26.0 34.0 3540 785 0.0601 0.0831 - -

125061 2x1.5 4 1.6 3.0 11.3 205 23 12.1 15.4 0.36 99

125078 2x2.5 4 2.0 3.5 12.4 255 31 7.41 9.45 0.34 118

125080 2x4 6 2.5 4.0 13.9 345 43 4.61 5.88 0.32 135

127302 2x6 6 3.1 4.5 15.2 430 55 3.08 3.93 0.30 150

125034 2x10 10 3.9 5.4 17.0 570 75 1.83 2.33 0.29 169

125035 2x16 16 5.0 6.4 19.8 815 100 1.15 1.47 0.27 186

127321 2x25 16 6.3 8.1 23.2 1135 130 0.727 0.927 0.27 203

127328 2x35 16 7.5 9.4 26.0 1415 161 0.524 0.669 0.25 215

127379 3G1.5 4 1.6 3.0 12.0 235 23 12.1 15.4 0.36 60

8 DRAKA Product information MOG 2010

ShipLine Plus

Page 9: Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables ... BIOI 250 V (HUCOM

TIOI 0.6/1 kV (HUSO)Armoured halogen free shipboard and offshore cable

Range, dimensions and technical data

pro

du

ct

nu

mber

no.

of

core

s an

d n

om

inal

cros

s-se

ctio

n

(n x

mm

2)1

nom

inal cr

oss-

sect

ion

al are

a

of t

he

eart

h

lead (

mm

2)

nom

inal

con

du

ctor

dia

met

er (

mm

)

nom

inal

core

dia

met

er

(mm

)

nom

inal

ou

ter

dia

met

er

(mm

)

appro

xim

ate

w

eight

(k

g/k

m)

maxim

um

cu

rren

t

rati

ng

(A)2

con

du

ctor

resi

stan

ce

at

20

°C

DC

/km

)

con

du

ctor

resi

stan

ce a

t 9

0 °

C, 6

0 H

z

(Ω/k

m)

self

in

du

c tan

ce

(mH

/km

)

work

ing

capaci

tan

ce

(nF/

km)3

127380 3G2.5 4 2.0 3.5 13.0 290 31 7.4 19.45 0.34 70

125020 3x1.5 4 1.6 3.0 12.0 235 20 2.1 15.4 0.36 121

125016 3x2.5 4 2.0 3.5 13.0 290 28 7.41 9.45 0.34 140

125021 3x4 4 2.5 4.0 14.5 400 37 4.61 5.88 0.32 157

125022 3x6 6 3.1 4.5 15.9 485 47 3.08 3.93 0.30 172

125019 3x10 10 3.9 5.4 18.0 685 65 1.83 2.33 0.29 191

125024 3x16 16 5.0 6.4 20.8 960 87 1.15 1.47 0.27 209

125023 3x25 16 6.3 8.1 24.6 1365 110 0.727 0.927 0.27 225

125069 3x35 16 7.5 9.4 27.7 1755 137 0.524 0.669 0.25 238

125067 3x50 25 8.7 10.8 32.7 2440 167 0.387 0.494 0.25 251

124995 3x70 35 10.5 12.8 37.7 3370 214 0.268 0.343 0.24 264

125032 3x95 50 12.4 14.7 43.3 4585 259 0.193 0.248 0.23 275

125026 3x120 60 14.0 16.5 47.7 5705 301 0.153 0.198 0.23 284

125030 3x150 70 15.5 18.4 52.2 6805 347 0.124 0.162 0.23 292

127381 4G1.5 4 1.6 3.0 12.8 265 20 12.1 15.4 0.39 129

127382 4G2.5 6 2.0 3.5 14.3 360 28 7.41 9.45 0.36 149

125082 4x1.5 4 1.6 3.0 12.8 265 20 12.1 15.4 0.39 129

125092 4x2.5 6 2.0 3.5 14.3 360 28 7.41 9.45 0.36 149

125094 4x4 6 2.5 4.0 15.8 465 37 4.61 5.88 0.34 166

125095 4x6 6 3.1 4.5 17.2 585 47 3.08 3.93 0.33 181

125036 4x10 10 3.9 5.4 19.4 805 65 1.83 2.33 0.31 200

125040 4x16 16 5.0 6.4 22.9 1165 87 1.15 1.47 0.30 218

125041 4x25 16 6.3 8.1 26.9 1680 110 0.727 0.927 0.30 235

128022 4x35 16 7.5 9.3 29.7 2090 137 0.524 0.669 0.28 247

128024 4x50 25 8.7 10.7 35.5 2975 167 0.387 0.494 0.27 261

128023 4x70 35 10.5 12.7 40.8 4050 214 0.268 0.343 0.26 273

128025 4x95 50 12.4 14.6 47.0 5540 259 0.193 0.248 0.25 285

127383 5G1.5 4 1.6 3.0 13.8 305 20 12.1 15.4 - 134

127384 5G2.5 2.5 2.0 3.5 15.5 420 28 7.41 9.45 - 154

125407 5x1.5 4 1.6 3.0 13.8 305 20 12.1 15.4 - 134

125408 5x2.5 2.5 2.0 3.5 15.5 420 28 7.41 9.45 - 154

125096 6x1.5 6 1.6 3.0 14.6 340 15 12.1 15.4 - ≤145

125100 6x2.5 6 2.0 3.5 16.1 425 20 7.41 9.45 - ≤165

125099 7x1.5 6 1.6 3.0 14.7 355 14 12.1 15.4 - ≤145

125117 7x2.5 6 2.0 3.5 16.1 445 19 7.41 9.45 - ≤165

125118 8x1.5 6 1.6 3.0 15.9 400 13 12.1 15.4 - ≤145

125122 10x1.5 10 1.6 3.0 17.9 470 12 12.1 15.4 - ≤145

125123 12x1.5 10 1.6 3.0 18.6 525 11 12.1 15.4 - ≤145

125126 16x1.5 10 1.6 3.0 20.3 645 10 12.1 15.4 - ≤145

125127 19x1.5 10 1.6 3.0 21.6 730 9 12.1 15.4 - ≤145

125128 24x1.5 16 1.6 3.0 24.8 925 8 12.1 15.4 - ≤145

9DRAKA Product information MOG 2010

ShipLine Plus

Page 10: Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables ... BIOI 250 V (HUCOM

TIOI 0.6/1 kV (HUSO)Armoured halogen free shipboard and offshore cable

Other cross-sections and numbers of cores are available on request.

1 G = including green/yellow2 The current rating is based on an ambient temperature of 45 °C and a

maximum operating temperature of 90 °C, according to IEC 60092-

352 Table A.4:

I. For singel core cables, Method G: 3 cores spaced in free air

II. For multi-core cables, Method E: Multi-core cables in free air

- For 3G core cables, the values for 2 loaded cores are given.

- For 4 en 5 core cables, the values for 3 loaded cores are given.

Correction factors for different ambient temperatures are

given on page 21.3 Working capacitance for one-phase asymmetrical or three-phase

symmetrical system. The working capacitance of multicore types n>5

depends on the way the wires are connected.

Installation recommendations

Minimum bending radius during installation

Minimum bending radius fixed installed

Maximum tensile load during installation

Minimum installation temperature

8 x D 6 x D 50 N * total cross section conductors -20 °C

10 DRAKA Product information MOG 2010

ShipLine Plus

Page 11: Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables ... BIOI 250 V (HUCOM

TIOI (c) 250 V (HUCOM)Armoured halogen free shipboard and offshore cable

Application

Armoured instrumentation and communication cable for fixed

installations on ships and offshore units where cable protection is

required.

Suitable for both indoor and outdoor installations.

Properties regarding fire performance

Halogen Free - According to IEC 60754-1,2

Low smoke - According to IEC 61034-1,2

Flame retardant - According to IEC 60332-3-22(cat.A)

Design standard: IEC 60092-376

Max. conductor temp.: 90°C

Nominal voltage: 250V

Test voltage: 1.5 kV AC

Core identification

The pairs have the following number identification:

Pair no. 1 core no. 1 and 2

Pair no. 2 core no. 3 and 4

Pair no. 3 core no. 5 and 6

Pair no. 4 etc.

1x3 cores (triple) is identified with no. 1, 2 and 3

1x4 cores (quad):

Pair no.1 core no. 1 and 2

Pair no.2 core no. 3 and 4

CODE LETTER

Conductor Annealed stranded circular copper

Insulation T Crosslinked polyethylene, XLPE

Lay up Numbered cores twisted to pair/triple/quad and wrapped with polyester tape. Pairs/triple/quad are laid up and collectively screened by aluminium polyester tape with tinned copper drain wire 0,5 mm2.

Inner sheath I Flame retardant halogen free thermoplastic compound, SHF1

Armour/screen O Tinned copper wire braid. PETP-tape.

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

Outer sheath colour Grey

Construction

Range, dimensions and technical data

Installation recommendations

Minimum bending radius during installation

Minimum bending radius fixed installed

Maximum tensile load during installation

Minimum installation temperature

8 x D 6 x D 50 N * total cross section conductors -20 °C

Type Capacitance approx. (nF/km) Loop inductance approx. (mH/km) Resistance at 20°C max. (Ω/km)

Single pair/triple 0.75 70 0.8 26.0

Single quad 0.75 60 0.8 26.0

Multi pair 0.75 60 0.8 26.0

Electrical characteristics

product number no. of cores and no-minal cross-section (n x mm2)

nominal conductor diameter (mm)

nominal core diameter (mm)

nominal outer diameter (mm)

approximate weight (kg/km)

125154 1x2x0.75 1.10 2.1 8.5 120

125156 1x4x0.75 1.10 2.1 9.5 155

125157 4x2x0.75 1.10 2.1 14.5 300

125159 7x2x0.75 1.10 2.1 17 405

125160 10x2x0.75 1.10 2.1 20.5 560

125161 14x2x0.75 1.10 2.1 22.5 700

125162 19x2x0.75 1.10 2.1 24.5 835

125163 24x2x0.75 1.10 2.1 28 1030

11DRAKA Product information MOG 2010

ShipLine Plus

Page 12: Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables ... BIOI 250 V (HUCOM

TI 0.6/1 kVHalogen free shipboard and offshore cable

Application

Unarmoured power and control cable for fixed installations on

ships and offshore units where cable protection is not required.

Suitable for both indoor and outdoor installations.

Properties regarding fire performance

Halogen Free - According to IEC 60754-1,2

Low smoke - According to IEC 61034-1,2

Flame retardant - According to IEC 60332-3-22(cat.A)

Design standard: IEC 60092-353

Max. conductor temp.: 90 °C (temporary overload permissible up

to 130 °C)

Nominal voltage: 0.6/1 kV

Test voltage: 3.5 kV AC

Core identification

Two cores Blue - Brown

Three cores Brown - Black - Grey

Four cores Blue - Brown - Black - Grey

Five cores Blue - Brown - Black - Grey - Black

With yellow/green.

Two cores + earth (3G) Yellow/green - Blue - Brown

Three cores + earth (4G) Yellow/green - Brown - Black - Grey

Four cores + earth (5G) Yellow/green - Blue - Brown - Black - Grey

CODE LETTER

Conductor Annealed stranded copper, 3-core cables ≥ 50 mm2 sector shaped, other types circular

Insulation T Crosslinked polyethylene, XLPE

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

Outer sheath colour Black

Range, dimensions and technical data

Construction

pro

du

ct

nu

mber

no.

of

core

s an

d n

om

inal

cros

s-se

ctio

n

(n x

mm

2)1

nom

inal

con

du

ctor

dia

met

er

(mm

)

nom

inal

core

dia

met

er

(mm

)

nom

inal

ou

ter

dia

met

er

(mm

)

appro

xim

ate

w

eight

(k

g/k

m)

maxim

um

cu

rren

t ra

tin

g

(A)2

con

du

ctor

resi

stan

ce

at

20

°C

DC

/km

)

con

du

ctor

resi

stan

ce a

t 9

0 °

C, 6

0 H

z

(Ω/k

m)

self

in

du

ctan

ce

(mH

/km

)

work

ing

capaci

tan

ce

(nF/

km)3

124841 2x1.5 1.6 3.0 8.4 80 23 12.1 15.4 0.33 52

124842 2x2.5 2.0 3.5 9.2 100 31 7.41 9.45 0.31 59

124843 2x4 2.5 4.0 10.3 135 43 4.61 5.88 0.29 65

124844 2x6 3.1 4.5 11.6 185 55 3.08 3.93 0.28 70

124845 2x10 3.9 5.4 13.3 275 75 1.83 2.33 0.26 76

124846 2x16 5.0 6.4 15.6 400 100 1.15 1.47 0.25 82

124850 3G1.5 1.6 3.0 8.8 100 23 12.1 15.4 0.33 51

125526 3G2.5 2.0 3.5 9.8 130 31 7.41 9.45 0.31 58

127213 3G4 2.5 4.0 11.1 190 43 4.61 5.88 0.29 64

127215 3G6 3.1 4.5 12.3 250 55 3.08 3.93 0.28 70

124849 3x1.5 1.6 3.0 8.8 100 20 12.1 15.4 0.33 101

124851 3x2.5 2.0 3.5 9.8 130 28 7.41 9.45 0.31 115

124852 3x4 2.5 4.0 11.1 190 37 4.61 5.88 0.29 128

124853 3x6 3.1 4.5 12.3 250 47 3.08 3.93 0.28 139

124854 3x10 3.9 5.4 14.3 385 65 1.83 2.33 0.26 154

124855 3x16 5.0 6.4 16.6 560 87 1.15 1.47 0.25 167

124856 3x25 6.3 8.1 20.7 880 110 0.727 0.927 0.25 179

124857 3x35 7.5 9.4 23.5 1220 137 0.524 0.669 0.24 188

124858 3x50 SS 6.8/12.2 8.9/14.3 22.8 1530 167 0.387 0.494 0.18 203

124859 3x70 SS 8.2/14.6 10.5/16.9 26.7 2155 214 0.268 0.343 0.18 211

124860 3x95 SS 10.9/17.3 13.5/21.9 30.2 2900 259 0.193 0.248 0.17 219

124861 3x120 SS 12.2/21.7 15.2/24.7 34 3680 301 0.153 0.198 0.17 224

124864 4G1.5 1.6 3.0 9.6 120 20 12.1 15.4 0.35 116

127212 4G2.5 2.0 3.5 10.7 165 28 7.41 9.45 0.33 131

127214 4G4 2.5 4.0 12.2 240 37 4.61 5.88 0.31 144

12 DRAKA Product information MOG 2010

ShipLine

Page 13: Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables ... BIOI 250 V (HUCOM

Range, dimensions and technical data

Installation recommendations

Minimum bending radius during installation

Minimum bending radius fixed installed

Maximum tensile load during installation

Minimum installation temperature

8 x D 6 x D 50 N * total cross section conductors -20 °C

TI 0.6/1 kVHalogen free shipboard and offshore cable

Other cross-sections and numbers of cores are available on request.

For single core and multi core (>5 cores) versions of TI-types, please refer to our TFXI-range (page 6).

1 SS = sector-shaped conductor

G = including green/yellow2 The current rating is based on an ambient temperature of 45 °C

and a maximum operating temperature of 90 °C, according to

IEC 60092-352 Table A.4: Method E: Multi-core cables in free air

- For 3G core cables, the values for 2 loaded cores are given.

- For 4 en 5 core cables, the values for 3 loaded cores are given.

Correction factors for different ambient temperatures are

given on page 21.3 Working capacitance for one-phase asymmetrical or three-phase

symmetrical system.

pro

du

ct

nu

mber

no.

of

core

s an

d n

om

inal

cros

s-se

ctio

n

(n x

mm

2)1

nom

inal

con

du

ctor

dia

met

er

(mm

)

nom

inal

core

dia

met

er

(mm

)

nom

inal

ou

ter

dia

met

er

(mm

)

appro

xim

ate

w

eight

(k

g/k

m)

maxim

um

cu

rren

t ra

tin

g

(A)2

con

du

ctor

resi

stan

ce

at

20

°C

DC

/km

)

con

du

ctor

resi

stan

ce a

t 9

0 °

C, 6

0 H

z

(Ω/k

m)

self

in

du

ctan

ce

(mH

/km

)

work

ing

capaci

tan

ce

(nF/

km)3

127216 4G6 3.1 4.5 13.5 320 47 3.08 3.93 0.30 156

127345 4G10 3.9 5.4 15.7 495 65 1.83 2.33 0.29 171

127416 4G16 5.0 6.4 18.5 740 87 1.15 1.47 0.28 184

127343 4G25 6.3 8.1 22.8 1145 110 0.727 0.927 0.28 197

124863 4x1.5 1.6 3.0 9.6 120 20 12.1 15.4 0.35 116

124865 4x2.5 2.0 3.5 10.7 165 28 7.41 9.45 0.33 131

124866 4x4 2.5 4.0 12.2 240 37 4.61 5.88 0.31 144

124867 4x6 3.1 4.5 13.5 320 47 3.08 3.93 0.30 156

124868 4x10 3.9 5.4 15.7 495 65 1.83 2.33 0.29 171

124869 4x16 5.0 6.4 18.5 740 87 1.15 1.47 0.28 184

127200 4x25 6.3 8.1 22.8 1145 110 0.727 0.927 0.28 197

124871 5G1.5 1.6 3.0 10.5 145 20 12.1 15.4 - 124

124873 5G2.5 2.0 3.5 11.9 205 28 7.41 9.45 - 137

124870 5x1.5 1.6 3.0 10.5 145 20 12.1 15.4 - 124

124872 5x2.5 2.0 3.5 11.9 205 28 7.41 9.45 - 137

13DRAKA Product information MOG 2010

ShipLine

Page 14: Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables ... BIOI 250 V (HUCOM

TXOI 0.6/1 kVArmoured halogen free shipboard and offshore cable

Application

Armoured power-, control- and lighting cable for fixed installations

on ships and offshore units where cable protection is required.

Suitable for both indoor and outdoor installations.

Properties regarding fire performance

Halogen Free - According to IEC 60754-1,2

Low smoke - According to IEC 61034-1,2

Flame retardant - According to IEC 60332-3-22 (cat.A)

Design standard: IEC 60092-353

Max. conductor temp.: 90°C (temporary overload permissible up

to 130 °C)

Nominal voltage: 0.6/1 kV

Test voltage: 3.5 kV AC

Core identification

Single core Black

Two cores Blue - Brown

Three cores Brown - Black - Grey

Four cores Blue - Brown - Black - Grey

Five cores Blue - Brown - Black - Grey - Black

> 5 cores White with black numbers

With yellow/green.

Two cores + earth (3G) Yellow/green - Blue - Brown

Three cores + earth (4G) Yellow/green - Brown - Black - Grey

CODE LETTER

Conductor Annealed stranded copper, 3-core cables ≥ 50 mm2 sector shaped, other types circular

Insulation T Crosslinked polyethylene, XLPE

Bedding X No bedding (Additional tapes may be applied)

Armour/screen O Tinned copper wire braiding

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

Outer sheath colour Black

Range, dimensions and technical data

Construction

pro

du

ct

nu

mber

no.

of

core

s an

d n

om

inal

cros

s-se

ctio

n

(n x

mm

2)1

nom

inal cr

oss-

sect

ion

al are

a

of t

he

eart

h

lead (

mm

2)

nom

inal

con

du

ctor

dia

met

er

(mm

)

nom

inal

core

dia

met

er

(mm

)

nom

inal

ou

ter

dia

met

er

(mm

)

appro

xim

ate

w

eight

(k

g/k

m)

maxim

um

cu

rren

t

rati

ng

(A)2

con

du

ctor

resi

stan

ce

at

20

°C

DC

/km

)

con

du

ctor

resi

stan

ce a

t 9

0 °

C, 6

0 H

z

(Ω/k

m)

self

in

du

ctan

ce

(mH

/km

)

work

ing

capaci

tan

ce

(nF/

km)3

124884 1x16 2.5 5.0 6.4 9.8 245 119 1.15 1.47 - -

124885 1x25 4 6.3 8.1 11.7 360 158 0.727 0.927 - -

124886 1x35 4 7.5 9.4 13.0 455 197 0.524 0.669 - -

124887 1x50 6 8.7 10.8 15.0 620 239 0.387 0.494 - -

124888 1x70 6 10.5 12.8 17.2 850 307 0.268 0.343 - -

124889 1x95 10 12.4 14.7 19.1 1115 374 0.193 0.248 - -

124890 1x120 10 14.0 16.5 21.1 1385 435 0.153 0.198 - -

124894 2x1.5 2.5 1.6 3.0 9.4 125 23 12.1 15.4 0.36 111

124895 2x2.5 2.5 2.0 3.5 10.2 155 31 7.41 9.45 0.34 133

124896 2x4 4 2.5 4.0 11.5 200 43 4.61 5.88 0.32 154

124897 2x6 6 3.1 4.5 13.0 280 55 3.08 3.93 0.30 172

124898 2x10 10 3.9 5.4 14.9 390 75 1.83 2.33 0.29 194

124899 2x16 16 5.0 6.4 17.6 600 100 1.15 1.47 0.27 214

127202 3G1.5 2.5 1.6 3.0 9.9 150 23 12.1 15.4 0.36 66

127198 3G2.5 2.5 2.0 3.5 10.8 185 31 7.41 9.45 0.34 78

124900 3x1.5 2.5 1.6 3.0 9.9 150 20 12.1 15.4 0.36 132

124901 3x2.5 2.5 2.0 3.5 10.8 185 28 7.41 9.45 0.34 156

124902 3x4 4 2.5 4.0 12.1 250 37 4.61 5.88 0.32 178

124903 3x6 6 3.1 4.5 13.9 355 47 3.08 3.93 0.30 197

124904 3x10 10 3.9 5.4 15.7 495 65 1.83 2.33 0.29 221

124905 3x16 16 5.0 6.4 18.6 760 87 1.15 1.47 0.27 243

124906 3x25 16 6.3 8.1 22.7 1095 110 0.727 0.927 0.27 264

14 DRAKA Product information MOG 2010

ShipLine

Page 15: Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables ... BIOI 250 V (HUCOM

Range, dimensions and technical data

Installation recommendations

Minimum bending radius during installation

Minimum bending radius fixed installed

Maximum tensile load during installation

Minimum installation temperature

8 x D 6 x D 50 N * total cross section conductors -20 °C

ShipLine

TXOI 0.6/1 kVArmoured halogen free shipboard and offshore cable

Other cross-sections and numbers of cores are available on request

1 SS = sector-shaped conductor

G = including green/yellow2 The current rating is based on an ambient temperature of 45 °C

and a maximum operating temperature of 90 °C, according to IEC

60092-352 Table A.4:

I. For singel core cables, Method G: 3 cores spaced in free air

II. For multi-core cables, Method E: Multi-core cables in free air

- For 3G core cables, the values for 2 loaded cores are given.

- For 4 en 5 core cables, the values for 3 loaded cores are given.

Correction factors for different ambient temperatures are

given on page 23 Working capacitance for one-phase asymmetrical or three-phase

symmetrical system. The working capacitance of multicore types

n>5 depends on the way the wires are connected.

pro

du

ct

nu

mber

no.

of

core

s an

d n

om

inal

cros

s-se

ctio

n

(n x

mm

2)1

nom

inal cr

oss-

sect

ion

al are

a

of t

he

eart

h

lead (

mm

2)

nom

inal

con

du

ctor

dia

met

er

(mm

)

nom

inal

core

dia

met

er

(mm

)

nom

inal

ou

ter

dia

met

er

(mm

)

appro

xim

ate

w

eight

(k

g/k

m)

maxim

um

cu

rren

t

rati

ng

(A)2

con

du

ctor

resi

stan

ce

at

20

°C

DC

/km

)

con

du

ctor

resi

stan

ce a

t 9

0 °

C, 6

0 H

z

(Ω/k

m)

self

in

du

ctan

ce

(mH

/km

)

work

ing

capaci

tan

ce

(nF/

km)3

124907 3x35 16 7.5 9.4 24.9 1340 137 0.524 0.669 0.25 279

124908 3x50 SS 25 6.8/12.2 8.9/14.3 24.8 1820 167 0.387 0.494 0.19 317

124909 3x70 SS 35 8.2/14.6 10.5/16.9 29.7 2580 214 0.268 0.343 0.19 336

124910 3x95 SS 50 9.7/17.3 12.1/19.7 33.1 3435 259 0.193 0.248 0.18 353

127205 3x120 SS 25 10.9/19.3 13.5/21.9 36.0 4075 301 0.153 0.198 0.18 366

127347 3x150 SS 25 12.2/21.7 15.2/24.7 39.1 4950 347 0.124 0.161 0.18 379

127203 4G1.5 2.5 1.6 3.0 10.6 175 20 12.1 15.4 0.39 135

127199 4G2.5 2.5 2.0 3.5 11.9 230 28 7.41 9.45 0.36 159

124913 4x1.5 2.5 1.6 3.0 10.6 175 20 12.1 15.4 0.39 135

124914 4x2.5 2.5 2.0 3.5 11.9 230 28 7.41 9.45 0.36 159

124915 4x4 6 2.5 4.0 13.8 340 37 4.61 5.88 0.34 181

124916 4x6 6 3.1 4.5 15.1 435 47 3.08 3.93 0.33 200

124917 4x10 10 3.9 5.4 17.3 630 65 1.83 2.33 0.31 224

124918 4x16 16 5.0 6.4 20.5 940 87 1.15 1.47 0.30 246

124919 4x25 16 6.3 8.1 24.4 1345 110 0.727 0.927 0.30 267

124920 5x1.5 2.5 1.6 3.0 11.8 210 16 12.1 15.4 - 136

124921 5x2.5 2.5 2.0 3.5 12.9 270 22 7.41 9.45 - 161

126759 6x1.5 4 1.6 3.0 12.7 240 15 12.1 15.4 - ≤145

124924 7x1.5 4 1.6 3.0 12.7 260 14 12.1 15.4 - ≤145

126760 8x1.5 6 1.6 3.0 15.5 340 13 12.1 15.4 - ≤145

124926 10x1.5 6 1.6 3.0 16.2 390 12 12.1 15.4 - ≤145

124927 12x1.5 6 1.6 3.0 16.9 440 11 12.1 15.4 - ≤145

124928 16x1.5 6 1.6 3.0 18.6 550 10 12.1 15.4 - ≤145

124929 19x1.5 6 1.6 3.0 19.7 620 9 12.1 15.4 - ≤145

124930 24x1.5 10 1.6 3.0 22.9 800 8 12.1 15.4 - ≤145

15DRAKA Product information MOG 2010

Page 16: Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables ... BIOI 250 V (HUCOM

TXOI (c) 250 VArmoured halogen free shipboard and offshore cable

Application

Armoured instrumentation and communication cable for fixed

installations on ships and offshore units where cable protection is

required. Suitable for both indoor and outdoor installations.

Properties regarding fire performance

Halogen Free - According to IEC 60754-1,2

Low smoke - According to IEC 61034-1,2

Flame retardant - According to IEC 60332-3-22(cat.A)

Design standard: IEC 60092-376

Max. conductor temp.: 90°C

Nominal voltage: 250V

Test voltage: 1.5 kV AC

Pair identification

The pairs have the following number identification:

Pair no. 1 core no. 1 and 2

Pair no. 2 core no. 3 and 4

Pair no. 3 core no. 5 and 6

Pair no. 4 etc.

1x3 cores (triple) is identified with no. 1, 2 and 3

1x4 cores (quad):

Pair no.1 core no. 1 and 2

Pair no.2 core no. 3 and 4

CODE LETTER

Conductor Annealed stranded circular copper

Insulation T Crosslinked polyethylene, XLPE

Lay up Numbered white cores twisted in pairs. (Two pair version stranded into a star quad). The pairs are twisted with different lay lengths to reduce mutual interference.

Bedding X No bedding (Additional tapes may be applied)

Armour/screen O Tinned copper wire braiding

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

Outer sheath colour Grey

Range, dimensions and technical data

Installation recommendations

Minimum bending radius during installation

Minimum bending radius fixed installed

Maximum tensile load during installation

Minimum installation temperature

8 x D 6 x D 50 N * total cross section conductors -20 °C

Type Capacitance approx. (nF/km) Loop inductance approx. (mH/km) Resistance at 20°C max. (Ω/km)

Single-pair 0.5 75 0.8 40.4

Multi-pair 0.5 75 0.8 40.4

Single-pair 0.75 70 0.8 26.0

Multi-pair 0.75 60 0.8 26.0

Electrical characteristics

Construction

product number no. of cores and no-minal cross-section(n x mm2)

nominal conductor diameter (mm)

nominal core diameter (mm)

nominal outer diameter (mm)

approximate weight (kg/km)

127257 1x2x0.5 0.93 1.75 6.6 65

127258 1x4x0.5 0.93 1.75 7.3 85

124931 1x2x0.75 1.10 2.1 7.3 80

124933 1x4x0.75 1.10 2.1 8.2 105

124934 4x2x0.75 1.10 2.1 12.2 195

124936 7x2x0.75 1.10 2.1 14.4 270

124937 10x2x0.75 1.10 2.1 17.8 410

124938 14x2x0.75 1.10 2.1 19.3 500

124939 19x2x0.75 1.10 2.1 21.5 630

124940 24x2x0.75 1.10 2.1 25.2 805

ShipLine

16 DRAKA Product information MOG 2010

Page 17: Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables ... BIOI 250 V (HUCOM

BI FR 0.6/1 kVHalogen free shipboard and offshore cable, fire resistant

Application

Unarmoured power and control cable for fixed installations on

ships and offshore units where cable protection is not required.

For instrumentation, communication, control, alarm, emergency and

critical systems. Suitable for both indoor and outdoor installations.

Properties regarding fire performance

Halogen Free - According to IEC 60754-1,2

Low smoke - According to IEC 61034-1,2

Flame retardant - According to IEC 60332-3-22 (cat.A)

Fire resistant - According to IEC 60331

Design standard: IEC 60092-353

Max. conductor temp.: 90°C (temporary overload permissible up

to 130 °C)

Nominal voltage: 0.6/1 kV

Test voltage: 3.5 kV AC

Core identification

Two cores Blue - Brown

Three cores Brown - Black - Grey

Four cores Blue - Brown - Black - Grey

CODE LETTER

Conductor Annealed stranded circular copper

Insulation B Mica-tape/crosslinked polyethylene, XLPE

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

Outer sheath colour Green

Construction

Range, dimensions and technical data

Installation recommendations

Minimum bending radius during installation

Minimum bending radius fixed installed

Maximum tensile load during installation

Minimum installation temperature

8 x D 6 x D 50 N * total cross section conductors -20 °C

ShipLine Fire Resistant

Other cross-sections and numbers of cores are available on request

1 The current rating is based on an ambient temperature of 45 °C

and a maximum operating temperature of 90 °C, according to

IEC 60092-352 Table A.4: Method E: Multi-core cables in free air

- For 4 core cables, the values for 3 loaded cores are given.

Correction factors for different ambient temperatures and cables laid

in bundles are given on page 21.2 Working capacitance for one-phase asymmetrical or three-phase

symmetrical system.

pro

du

ct

nu

mber

no.

of

core

s an

d n

om

inal

cros

s-se

ctio

n

(n x

mm

2)

nom

inal

con

du

ctor

dia

met

er

(mm

)

nom

inal

core

dia

met

er

(mm

)

nom

inal

ou

ter

dia

met

er

(mm

)

appro

xim

ate

w

eight

(k

g/k

m)

maxim

um

cu

rren

t ra

tin

g (

A)1

con

du

ctor

resi

stan

ce

at

20

°C

DC

/km

)

con

du

ctor

resi

stan

ce a

t 9

0 °

C, 6

0 H

z

(Ω/k

m)

self

in

du

ctan

ce

(mH

/km

)

work

ing

capaci

tan

ce

(nF/

km)2

126458 2x1.5 1.6 3.3 8.5 85 23 12.1 15.4 0.36 54

126461 2x2.5 2.0 3.8 9.5 110 31 7.41 9.45 0.34 59

126459 3x1.5 1.6 3.3 9.5 110 20 12.1 15.4 0.36 108

126462 3x2.5 2.0 3.8 10.0 145 28 7.41 9.45 0.34 118

126463 3x4 2.5 4.3 11.5 205 37 4.61 5.88 0.32 130

126460 4x1.5 1.6 3.3 10.0 135 20 12.1 15.4 0.39 128

127061 4x6 3.1 4.8 14.5 340 47 3.08 3.93 0.32 161

17DRAKA Product information MOG 2010

Page 18: Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables ... BIOI 250 V (HUCOM

BXOI FR 0.6/1 kVArmoured halogen free shipboard and offshore cable, fire resistant

Application

Armoured power-, control- and lighting cable for fixed installations

on ships and offshore units where cable protection is required. For

instrumentation, communication, control, alarm, emergency and

critical systems in both EX- and safe areas. Suitable for both indoor

and outdoor installations.

Properties regarding fire performance

Halogen Free - According to IEC 60754-1,2

Low smoke - According to IEC 61034-1,2

Flame retardant - According to IEC 60332-3-22 (cat.A)

Fire resistant - According to IEC 60331

Design standard: IEC 60092-353

Max. conductor temp.: 90°C (temporary overload permissible up

to 130 °C)

Nominal voltage: 0.6/1 kV

Test voltage: 3.5 kV AC

Pair identification

Two cores Blue - Brown

Three cores Brown - Black - Grey

Five cores Blue - Brown - Black - Grey - Black

> 5 cores White with black numbers

CODE LETTER

Conductor Annealed stranded circular copper

Insulation B Mica-tape/crosslinked polyethylene, XLPE

Inner sheath X No bedding (Additional tapes may be applied)

Armour/screen O Tinned copper wire braiding

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

Outer sheath colour Green

Range, dimensions and technical data

Construction

Installation recommendations

Minimum bending radius during installation

Minimum bending radius fixed installed

Maximum tensile load during installation

Minimum installation temperature

8 x D 6 x D 50 N * total cross section conductors -20 °C

ShipLine Fire Resistant

Other cross-sections and numbers of cores are available on request

1 The current rating is based on an ambient temperature of 45 °C

and a maximum operating temperature of 90 °C, according to

IEC 60092-352 Table A.4: Method E: Multi-core cables in free air

- For 5 core cables, the values for 3 loaded cores are given.

Correction factors for different ambient temperatures are

given on page 21.

2 Working capacitance for one-phase asymmetrical or three-phase

symmetrical system. The working capacitance of multicore types n>5

depends on the way the wires are connected

pro

du

ct

nu

mber

no.

of

core

s an

d n

om

inal

cros

s-se

ctio

n

(n x

mm

2)

nom

inal cr

oss-

sect

ion

al are

a

of t

he

eart

h

lead (

mm

2)

nom

inal

con

du

ctor

dia

met

er

(mm

)

nom

inal

core

dia

met

er

(mm

)

nom

inal

ou

ter

dia

met

er

(mm

)

appro

xim

ate

w

eight

(k

g/k

m)

maxim

um

cu

rren

t

rati

ng

(A)1

con

du

ctor

resi

stan

ce

at

20

°C

DC

/km

)

con

du

ctor

resi

stan

ce a

t 9

0 °

C, 6

0 H

z

(Ω/k

m)

self

in

du

ctan

ce

(mH

/km

)

work

ing

capaci

tan

ce

(nF/

km)2

125758 2x1.5 2.5 1.6 3.3 10.0 135 23 12.1 15.4 0.39 130

125764 2x2.5 2.5 2.0 3.8 10.5 160 31 7.41 9.45 0.36 144

125760 3x1.5 2.5 1.6 3.3 10.5 160 20 12.1 15.4 0.39 145

125763 3x2.5 2.5 2.0 3.8 11.0 205 28 7.41 9.45 0.36 162

126457 3x4 4 2.5 4.3 12.5 275 37 4.61 5.88 0.34 185

126986 3x6 6 3.1 4.8 14.5 380 47 3.08 3.93 0.32 208

125765 3x10 10 4.4 5.8 16.8 535 65 1.83 2.33 0.30 219

126456 5x1.5 4 1.6 3.3 12.5 230 16 12.1 15.4 - 161

125761 7x1.5 6 1.6 3.3 13.5 290 14 12.1 15.4 - > 165

125762 12x1.5 6 1.6 3.3 18.0 480 11 12.1 15.4 - >165

18 DRAKA Product information MOG 2010

Page 19: Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables ... BIOI 250 V (HUCOM

Installation recommendations

Minimum bending radius during installation

Minimum bending radius fixed installed

Maximum tensile load during installation

Minimum installation temperature

8 x D 6 x D 50 N * total cross section conductors -20 °C

Type Capacitance approx. (nF/km) Loop inductance approx. (mH/km) Resistance at 20°C max. (Ω/km)

Single/multi-pair 0.75 80 0.8 26.0

Single-pair 1.5 90 0.8 12.8

Electrical characteristics

BXOI FR 250 VArmoured halogen free shipboard and offshore cable, fire resistant

Application

Armoured instrumentation and communication cable for fixed

installations on ships and offshore units where cable protection

is required. For instrumentation, communication, control, alarm,

emergency and critical systems in both EX- and safe areas. Suitable

for both indoor and outdoor installations.

Properties regarding fire performance

Halogen Free - According to IEC 60754-1,2

Low smoke - According to IEC 61034-1,2

Flame retardant - According to IEC 60332-3-22 (cat.A)

Fire resistant - According to IEC 60331

Design standard: IEC 60092-353

Max. conductor temp.: 90°C

Nominal voltage: 250V

Test voltage: 1.5 kV AC

Core identification

The pairs have the following number identification:

Pair no. 1 core no. 1 and 2

Pair no. 2 core no. 3 and 4

Pair no. 3 core no. 5 and 6

Pair no. 4 etc

CODE LETTER

Conductor Annealed stranded circular copper

Insulation B Mica-tape/crosslinked polyethylene, XLPE

Lay up Colour coded cores twisted together and wrapped with polyester tape. The pairs are twisted with different lay length to reduce mutual interference. Pairs are identified by numbered tape.

Bedding X No bedding (Additional tapes may be applied)

Armour/screen O Tinned copper wire braiding

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

Outer sheath colour Green

Construction

Range, dimensions and technical data

ShipLine Fire Resistant

product number no. of cores and no-minal cross-section (n x mm2)

nominal conductor diameter (mm)

nominal core diameter (mm)

nominal outer diameter (mm)

approximate weight (kg/km)

125560 1x2x0.75 1.10 2.5 8.5 95

125766 2x2x0.75 1.10 2.5 13.0 170

127139 4x2x0.75 1.10 2.5 15.5 240

125767 7x2x0.75 1.10 2.5 18.5 390

130049 19x2x0.75 1.10 2.5 23.5 1040

127041 1x2x1.5 1.60 3.0 9.5 115

19DRAKA Product information MOG 2010

Page 20: Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables ... BIOI 250 V (HUCOM

Data cables

Data cables of the Universal Cable series UC are always in

use wherever it is a question of high-speed data transmission

in local networks (LAN). Whether Cat5e (Class D), Cat6 (Class

E), Cat6a (Class Ea), Cat7 (Class Fa), Class7+ or multimedia

- all data cables are in accordance with ISO/IEC 11801, EN

50173 and EIA/TIA 568A.

On ships, data cables of the UC series are used for

standarized and manufacturer-independent networks - Token

Ring, Ethernet, ISDN, TPDDI, Fast-Ethernet 100BaseTX, ATM,

Gigabit-Ethernet 1000Base T or 10 GbE.

RF cables

The radio-frequency cables are used in transmitter and

receiver installations in radio communication as well as in the

entire field of commercial radio-frequency technology and

electronics.

RG cables of the American standard according to MIL-C-17G

have become the global standard. They are always applied

where high quality is required.

On ships, they serve as cables for transmitters and receivers

in the radio technology and as connection cables in the

navigation technology.

Video and Audio cables

Audio cables are a perfect basis for digital and analogue

transmission of audio signals. The digital audio cables are in

accordance with the AES/EBU standard.

Video cables are used as coaxial cables with a charcteristic

impendence of 75Ω for the connection of recording and

intermediate amplifiers as well as monitors and cameras.

The specified frequency range up to 5000 MHz permits the

application of the video cables for serial digital transmission,

HDTV and future transmission technology.

In the ship’s own television studio for example, audio and

video cables are applied in order to enable the transmission

from the studio to the cabin.

CATV cables

CATV cables are used in private and commercial trunk lines

and TV signal distribution networks. They can be applied

from the headend. Drop cables are used in private and

commercial TV signal distribution networks and as antenna

cables for terrestric and satellite broadcast systems.

On ships, CATV cables are applied for example for the

transmission of TV channels which are received via satellite

TV or terrestric antennas and transmitted to the cabins.

Overview

Data cables

20 DRAKA Product information MOG 2010

Page 21: Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables ... BIOI 250 V (HUCOM

Electrical characteristics of cables

Data cables

Ambient temp. °C 25 30 35 40 45 50 55 60 65 70 75

Rating factor 1.2 1.15 1.11 1.05 1 0.94 0.88 0.82 0.74 0.67 0.58

Maximum resistance of copper conductors according to IEC 60228 Class 2

Conductor resistance

Influence of temperature on the conductor resistance

Correction factors for ambient temperatures other than 45 ˚C, according to IEC 60092

Current ratings for continuous load

Minimum number of strands

mm2 Circular Conductor

Sector-shaped Conductor

Ω/km

1.5 7 - 12.1

2.5 7 - 7.41

4 7 - 4.61

6 7 - 3.08

10 7 - 1.83

16 7 - 1.15

25 7 - 0.727

35 19 (7) - 0.524

50 19 (19) 19 (6) 0.387

70 37 (19) 37 (12) 0.268

95 37(19) 37 (15) 0.193

120 61 (37) 37 (18) 0.153

150 61 (37) 37 (18) 0.124

Temp. °C Correction factor

20 1.000

25 1.020

30 1.039

35 1.059

40 1.079

45 1.098

50 1.118

55 1.138

60 1.157

65 1.177

70 1.196

75 1.216

80 1.236

85 1.255

90 1.275

Short circuit currentThe maximum permissible short circuit current for

different cables is given in the figure aside.

This figure is based on the formula:

lk = 143·S/√t

lk = the maximum permissible short circuit current

S = the cross-section of the conductor in mm2

t = the duration of the short circuit in seconds

Tk start = 90 ˚C

Tk end = 250 ˚C

The formula is applicable for an increase in temperature

from 90 ˚C at the start to 250 ˚C at the end of the

short circuit, when the duration of the short circuit is

less than 5 seconds.

100,0

10,0

1,0

0,1

0,00,1 1,0 10,0

1,5

2,5

4

6

10

16

25

35

50

70

95

120

150

Permissible short circuit current

Sh

ort

cir

cuit

cu

rre

nt

in k

A

Cro

ss-s

ect

ion

of

the

co

nd

uct

or

in m

m2

Duration of the short circuit in seconds

Table 1 Table 2

Table 3

21DRAKA Product information MOG 2010

Page 22: Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables ... BIOI 250 V (HUCOM

Electrical characteristics of cables

Data cables

The calculation of the working capacitance

Number of cores Cable type Voltage type Working capacitance

2 unscreened AC C12

screened AC symmetricalAC asymmetrical, screen grounded

C12 + ½.C11

C12 + C11

3 unscreened 3 phase AC symmetrical2 phase AC symmetrical, one core grounded

3.C12

1½.C12

screened 3 phase AC symmetrical2 phase AC symmetrical, one core grounded

3.C12 + C11

1½.C12 + ½.C11

4 unscreened 3 phase AC, one core grounded CS = 3.C12 + C13

CR,T = 2½.C12 + 3.C13

screened 3 phase AC, one core and screen grounded CS = C11 + 3.C12 + C13

CR,T = C11 + 2½.C12 + 3.C13

Working capacitance

The actual value of the working capacitance of cables depends on the

cable type, the electrical circuit in which the cable functions and, for

unscreened and unarmoured cables, the method of installation.

The working capacitance of a cable can be calculated by substitution

of the partial capacitances in the formulas of table 4 by the value of

table 5 and 6.

As the theoretical calculation of the working capacitance of multicore

cables, 1.5 or 2.5 mm2, is very complex, no partial capacitances have

been indicated. Generally, the value of the working capacitance will,

in the case, be less than 100 nF/km.

CS = working capacitance of phase S

CR,T = working capacitance of phases R and T

screen

C 22

C 23

C 14

C 13

C 24

C 33

C 11 C 44

C 12 C 34

2 3

1 4

screen

C 22

C 13C 11 C 33

C 12 C 23

2

1 4

screen

C 11 C 22C 12

1 2

C 23

C 14

C 13

C 24C 12 C 34

2 3

1 4C 13

C 12 C 23

2

1 4

C 12

1 2

The partial capacitance are defined as follows:

Capacitance of Draka marine cables

Table 4

22 DRAKA Product information MOG 2010

Page 23: Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables ... BIOI 250 V (HUCOM

Electrical characteristics of cables

Data cables

Partial capacitances in nF/kmTI and TXOI

Partial capacitances in nF/kmTFXI and TIOI

TI in nF/km

C12 C13

Number of cores

mm2 2 3 4 4

1.5 51 34 36 8

2.5 57 38 40 8

4 63 42 45 8

6 69 46 49 8

10 78 52 55 7

16 87 58 62 7

25 - 57 61 7

35 - 63 - -

50 - 64 - -

70 - 67 - -

95 - 72 - -

120 - 74 - -

150 - - - -

TFXI in nF/km

C12 C13

Number of cores

mm2 2 3 4 4

1.5 58 28 41 10

2.5 64 43 46 9

4 72 48 51 9

6 78 52 56 9

10 88 59 62 8

16 98 66 70 8

25 - 65 - -

35 - 71 - -

50 - 72 - -

70 - 76 - -

95 - 82 - -

120 - 83 - -

150 - 81 - -

TXOI in nF/km

C11 C12 C13

Number of cores

mm2 2 3 4 2 3 4 4

1.5 97 80 71 21 18 19 7

2.5 108 88 77 27 22 23 7

4 121 96 84 33 27 29 7

6 133 105 91 39 31 34 6

10 140 109 94 45 36 40 6

16 163 125 107 54 42 48 6

25 - 127 108 - 42 - -

35 - 141 - - 48 - -

50 - 157 - - 53 - -

70 - 165 - - 55 - -

95 - 184 - - 60 - -

120 - 189 - - 62 - -

150 - 184 - - 61 - -

TIOI in nF/km

C11 C12 C13

Number of cores

mm2 2 3 4 2 3 4 4

1.5 79 61 52 26 21 23 8

2.5 88 68 57 30 23 26 8

4 99 76 64 33 26 30 8

6 108 82 70 37 29 33 7

10 123 93 79 42 32 38 7

16 147 111 94 47 36 43 6

25 152 115 98 47 36 43 6

35 173 130 110 51 39 47 6

50 - 125 105 51 39 47 6

70 - 136 114 54 41 50 5

95 - 151 127 57 43 54 5

120 - 158 - - 44 - -

150 - 158 - - 44 - -

Remark:

Measurements in practice have shown that the scatter of partial

capacitances of XLPE-insulated cables can amount to 40%

Table 5

Table 6

23DRAKA Product information MOG 2010

Page 24: Product information · BXOI FR 0.6/1 kV Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables ... BIOI 250 V (HUCOM

Draka Kabel B.V. Hamerstraat 2-4 | 1021 JV Amsterdam | Postbus 1013 | 1000 BA Amsterdam

T. 020 637 99 11 | F. 020 637 93 63 | [email protected] | www.drakaservice.nl