Product Catalog - HOSANAhosanavt.com/wp-content/uploads/2020/04/AMETEK-catalog... · 2020. 4....
Transcript of Product Catalog - HOSANAhosanavt.com/wp-content/uploads/2020/04/AMETEK-catalog... · 2020. 4....
Product
Catalog
TECHNICAL & INDUSTRIAL PRODUCTS
627 Lake Street, Kent, OH 44240Tel: 330-673-3452 • Fax: 330-677-3306 • www.ametektip.comE-mail: [email protected]
About AMETEK . . . . . . . . . . . . . . . . . . . . . . . . . 4
5 | Brushless DC BlowersLow Voltage Brushless DC Blowers
3.0” (76mm) BLDC, 12/24 VDC . . . . . . . . . . . . . . . . 6
3.3” (84mm) BLDC, 12/24 VDC . . . . . . . . . . . . . . . . 8
4.5” (114mm) BLDC, 12/24 VDC . . . . . . . . . . . . . . 10
5.0” (127mm) BLDC, 12/24 VDC S.F. . . . . . . . . . . . 12
5.0” (127mm) BLDC, 12/24 VDC H.F. . . . . . . . . . . . 14
5.1” (130mm) BLDC, 24 VDC . . . . . . . . . . . . . . . . . 16
5.7” (145mm) BLDC Bypass, 24 VDC S.F. . . . . . . . 18
5.7” (145mm) BLDC Bypass, 24 VDC H.F. . . . . . . . 20
5.7” (145mm) BLDC Thru Flow, 24 VDC S.F. . . . . . 22
5.7” (145mm) BLDC Thru Flow, 24 VDC H.F. . . . . . 24
5.7” (145mm) BLDC Bypass, 48 VDC S.F. . . . . . . . 26
5.7” (145mm) BLDC Bypass, 48 VDC H.F. . . . . . . . 28
5.7” (145mm) BLDC Thru Flow, 48 VDC S.F. . . . . . 30
5.7” (145mm) BLDC Thru Flow, 48 VDC H.F. . . . . . 32
5.7” (145mm) BLDC Bypass, 72 VDC S.F. . . . . . . . 34
5.7” (145mm) BLDC Bypass, 72 VDC H.F. . . . . . . . 36
5.7” (145mm) BLDC Thru Flow, 72 VDC S.F. . . . . . 38
5.7” (145mm) BLDC Thru Flow, 72 VDC H.F. . . . . . 40
High Voltage Brushless DC Blowers
5.7” (145mm) Thru Flow, 250 Watt/120V S.F. . . . . 42
5.7” (145mm) Thru Flow, 250 Watt/120V H.F. . . . . 44
5.7” (145mm) Thru Flow HD, 250 Watt/120V S.F. . 46
5.7” (145mm) Bypass, 250 Watt/120V S.F. . . . . . . 48
5.7” (145mm) Bypass, 250 Watt/120V H.F. . . . . . . 50
5.7” (145mm) Thru Flow, 400 Watt/240V S.F. . . . . 52
5.7” (145mm) Bypass, 400 Watt/240V S.F. . . . . . . 54
5.7” (145mm) Bypass, 400 Watt/240V H.F. . . . . . . 56
5.7” (145mm) Bypass, 800 Watt/120V S.F. . . . . . . 58
5.7” (145mm) Bypass, 800 Watt/120V H.F. . . . . . . 60
5.7” (145mm) Bypass, 1200 Watt/240V S.F. . . . . . 62
5.7” (145mm) Bypass, 1200 Watt/240V H.F. . . . . . 64
EMI Windjammer Filters . . . . . . . . . . . . . . . . . . . . . 65
Variable Flow Filters for Windjammer and Nautilair 67
Nautilair 7.6 (192mm) Variable Speed 24 VDC . . . . 68
Nautilair 7.6 (192mm) Variable Speed 120 VAC . . . 70
Nautilair 7.6 (192mm) Variable Speed 240 VAC . . . 72
Nautilair 8.0 (192mm) Variable Speed 120 VAC . . . 74
Nautilair 8.9” (225mm) Variable Speed 120 VAC . . 76
Nautilair 8.9” (225mm) Variable Speed 240 VAC . . 78
Nautilair 12.3 (315mm) Variable Speed 120 VAC . . 80
Nautilair 12.3 (315mm) Variable Speed 240 VAC . . 82
Control Option Selection Guide . . . . . . . . . . . . . . . 84
85 | Brushless DC Fans and Impeller-Style BlowersBrushless DC Fans
RTP10 Brushless DC Fan, 12/24 VDC . . . . . . . . . . 86
RTP14 Brushless DC Fan, 24 VDC. . . . . . . . . . . . . 88
RTP16 Brushless DC Fan, 12/24 VDC . . . . . . . . . . 90
RTP16S Brushless DC Fan, 12/24 VDC . . . . . . . . . 92
Brushless DC Blowers
RTP1300 Impeller Style Blower, 12/24 VDC. . . . . . 94
RTP1400 Impeller Style Blower, 12/24 VDC. . . . . . 96
RTP1600 Impeller Style Blower, 12/24 VDC. . . . . . 98
RTP1700 Impeller Style Blower, 12/24 VDC. . . . . 100
103 | Pumps10 Gallon Seal-less Pump . . . . . . . . . . . . . . . . . . 104
12 Gallon Seal-less Pump . . . . . . . . . . . . . . . . . . 106
18 Gallon Seal-less Pump . . . . . . . . . . . . . . . . . . 108
26 Gallon Seal-less Pump . . . . . . . . . . . . . . . . . . 110
113 | Controllers5 Amp BLDC Motor/Blower Controller . . . . . . . . 114
10 Amp BLDC Motor/Blower Controller . . . . . . . . 115
20 Amp BLDC Motor/Blower Controller . . . . . . . 116
20 Amp Programmable Motor/Blower Controllerwith Digital Signal Processor (DSP) . . . . . . . . . . . 117
Motor/Blower Controller Number Chart . . . . . . . . 118
119 | Engineering NotesMotor/Blower Sizing Form . . . . . . . . . . . . . . . . . . 119
Engineering Basics – Air Moving (Flow, Pressure,
Density, Specifi c Gravity, Velocity, Pressure Drop/
Back Pressure/Impedance) . . . . . . . . . . . . . . . . . . . . 120
Density Correction Chart . . . . . . . . . . . . . . . . . . . 121
Physical Laws for Blower Applications. . . . . . . . . 122
Engineering Basics – Blower Application Law Examples (Air Density, Horsepower) . . . . . . . . . 123
Engineering Basics – Motion . . . . . . . . . . . . . . . . 124
Engineering Basics – Pump . . . . . . . . . . . . . . . . . 124
Standard Engineering Conversions . . . . . . . . . . . 125
126 | Contact InformationSales Offi ces / Distributors . . . . . . . . . . . . . . . . . . 126
TA
BLE
OF C
ON
TE
NT
S
3
ametek
electromechanical
group (emg)
4
... is one of the world’s largest producers of high speed electric
motor products for original equipment manufacturers (OEMs).
In business since 1915, EMG uses its core competencies in
motion and air movement products as engineered solutions for
application-specifi c needs. A business unit of AMETEK EMG,
AMETEK Technical & Industrial Products offers brushless DC
motor-, blower-, and controller-based solutions.
The standard product lines of AMETEK Technical &
Industrial Products cover a wide range of application demands.
If there is a need for a product with unique performance,
mounting, environment or agency requirements, AMETEK
Technical & Industrial Products can supply the solution. Whether
a customer needs a standard or special design, AMETEK has
the solution for your application and offers economies of scale
that only can be accomplished by a company that produces
more than 26 million motor products per year. With multiplant
capability and fl exibility, AMETEK Technical & Industrial Products
is positioned to support our customers’ global programs.
AMETEK brushless DC motors, blowers, fans, pumps, and
controllers are an ideal choice for such varied applications as
medical instruments, robotics, pumps, compressors, business
equipment, fans, machine tools, tape drives, printing, fuel
cells, textiles, or any other precise rotary motion/air delivery
applications.
5AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
Brushless DC blowers... offer variable (speed) output for a wide range of vacuum or pressure applications. Standard blower designs offer brushless DC motor drives coupled to high effi ciency fan systems in a compact, cost effective package. Standard models are available in a wide range of input voltages, including 12, 24, 48, and 72 VDC. A complete product line of brushless DC blowers that accepts line voltage input (100 VAC, 120 VAC, and 240 VAC) are also available. AMETEK Brushless DC Blowers are not designed for, and should not be used in, life sustaining applications. AMETEK Brushless DC Blowers are not 100% sealed and therefore should not be used with fl ammable or hazardous gases.
Blower Selection . . .
offers a wide variety of standard products available from AMETEK. Nine different blower families are available in standard confi gurations. These include six low voltage and seven high voltage product lines. The low voltage products provide output pressure up to 97.7” H2O and fl ows up to 160.3 CFM. The high voltage products provide output pressure up to 169” H2O (pressure) and fl ows up to 545 CFM.
BRUS
HLES
S DC
BLO
WER
S
LOW VOLTAGE PRODUCTSBlower Diameter Operating Voltage
VDCFlow
CFM (m3/hr)Pressure
In. H2O (mBar)Vacuum
In. H2O (mBar)
3” (76mm) 12, 24 0-17.7 (0-30.1) 0-10.1 (0-25.1) 0-9.8 (0-24.4)3.3” (84mm) 12, 24 0-7.4 (0-12.6) 0-24.5 (0-61) 0-23.8 (0-59.2)4.5” (114mm) 12, 24 0-9.8 (0-16.7) 0-28.3 (0-70.4) 0-27.5 (0-68.4)5” (127mm) 12, 24 0-44.6 (0-75.8) 0-24.9 (0-62) 0-24.2 (0-60.2)
5.1” (130mm) 12, 24 0-26.3 (0-44.7) 0-50.9 (0-127) 0-49.4 (0-123)5.7” (145mm) 24, 48, 72 0-190 (0-323) 0-97.7 (0-242) 0-94.7 (0-236)7.6” (192mm) 24 0-122 (0-207) 0-15 (0-37) 0-14 (0-35)
HIGH VOLTAGE BYPASS PRODUCTSBlower Diameter Operating Voltage
VACFlow
CFM (m3/hr)Pressure
In. H2O (mBar)Vacuum
In. H2O (mBar)
5.7” (145mm) 120 (250 Watt) 0-130.5 (0-222) 0-80.5 (0-200) 0-78.4 (0-195)5.7” (145mm) 120 (800 Watt) 0-242 (0-412) 0-117 (0-285) 0-106 (0-263)5.7” (145mm) 240 (400 Watt) 0-125 (0-212) 0-72 (0-174) 0-60 (0-149)5.7” (145mm) 240 (1200 Watt) 0-274 (0-466) 0-169 (0-421) 0-154 (0-385)
HIGH VOLTAGE THRU-FLOW PRODUCTSBlower Diameter Operating Voltage
VACFlow
CFM (m3/hr)Pressure
In. H2O (mBar)Vacuum
In. H2O (mBar)
5.7” (145mm) 120 (250 Watt) 0-130.5 (0-222) 0-51.5 (0-128) 0-50 (0-124)5.7” (145mm) 240 (400 Watt) 0-67 (0-114) 0-50 (0-124) 0-47 (0-117)7.6” (192mm) 120 0-165 (0-280) 0-45 (0-112) 0-43 (0-107)7.6” (192mm) 240 0-160 (0-272) 0-45 (0-112) 0-43 (0-107)8.0” (204mm) 120 0-101 (0-172) 0-9 (0-22) 0-8.5 (0-21)8.9” (225mm) 120 0-480 (0-816) 0-13 (0-32.3) 0-12.6 (0-31.4)8.9” (225mm) 240 0-545 (0-926) 0-14.3 (0-35.6) 0-13.9 (0-34.6)12.3” (315mm) 120 0-780 (0-1325) 0-14 (0-35) 0-13.5 (0-33.5)12.3” (315mm 240 0-800 (0-1359) 0-15.5 (0-38.5) 0-14.5 (0-36)
6
3.0” (76mm) BLDC Low-Voltage Blower 12/24 VDC
Blower Data Unit of MeasurePart Number
119349* 119350*
Voltage Input VDC 12 24
Stages — 1 1
Pressure, Maximum (Sealed Pressure) in. H2O, Sealed 10.1 10.1
mBar 25.1 25.1
Flow Rate, Maximum (Open Flow) CFM 17.7 17.7
m3/hr 30.1 30.1
* These part numbers are available through AMETEK Technical & Industrial Products’ distributors.
2.94(74.68)
1.31(33.27)
2.67(67.82)
1.24(31.50)
INCH(MM)
3.42(86.84)
2.00(50.80)
.85(21.59) .78
(19.81)1.99
(50.55)
1.23(31.24)
.74(18.80)
EXHAUST
INTAKEØ .812 (20.62)
Ø 1.00 (25.40)
Ø 1.75 (44.45)
Ø .750 (19.05)
2X 12.0±25.4 (304.8±25.4) 20 GA. LEADS UL 1007 RED (+) BLACK (–)
NOTES:• Temperature: Working Air: 0°C to 45°C, Ambient Air: 0°C to 45°C, Storage Air: -40°C to 85°C.• Dielectric Testing: 200 volts applied for one second between power leads and motor body, one milliamp leakage max.• Speed is controlled by varying the input voltage (there is a minimum voltage threshold, unless using the separate V+ option).• Customized performance available upon request. Please contact AMETEK Technical & Industrial Products’ Marketing and Sales Department.• When blowers are used in a vacuum condition, there will be an approximate reduction of 3% in the air performance.• Hard mounting of blower can be done by clamping around the motor’s AL casting.• 2 wire power connection (Red = positive DC, Black = negative DC).• Please observe proper polarity for power connections. Improper connection will damage the blower’s electronics.• Blower/motor is equiped with basic internal drive controller.• Optional – Motor confi guration available with connection to external controller.• Optional – 2 plane balanced for reduced vibration (slight dimensional change and increased motor axial length).• Optional – FPS (frequency pulse signal) for tach output.• Optional – Separate V+ signal wire for input power to hall sensors in order to obtain slow speed operation.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
LOW
-VOL
TAGE
BLDC
BLO
WER
S
7
3.0” (76mm) BLDC Low-Voltage Blower 12/24 VDC TYPICAL PERFORMANCE
®
8
3.3” (84mm) BLDC Low-Voltage Blower 12/24 VDC
Blower Data Unit of MeasurePart Number
119497 119498
Voltage Input VDC 12 24
Stages — 1 1
Pressure, Maximum (Sealed Pressure) in. H2O, Sealed 24.5 24.5
mBar 61.0 61.0
Flow Rate, Maximum (Open Flow) CFM 7.4 7.4
m3/hr 12.6 12.6
NOTES:• Temperature: Working Air: 0°C to 45°C, Ambient Air: 0°C to 45°C, Storage Air: -40°C to 85°C.• Dielectric Testing: 200 volts applied for one second between power leads and motor body, one milliamp leakage max.• Speed is controlled by varying the input voltage (there is a minimum voltage threshold, unless using the separate V+ option).• Customized performance available upon request. Please contact AMETEK Technical & Industrial Products’ Marketing and Sales Department.• When blowers are used in a vacuum condition, there will be an approximate reduction of 3% in the air performance.• Hard mounting of blower can be done by clamping around the motor’s AL casting.• 2 wire power connection (Red = positive DC, Black = negative DC).• Please observe proper polarity for power connections. Improper connection will damage the blower’s electronics.• Blower/motor is equiped with basic internal drive controller.• Optional – Motor confi guration available with connection to external controller.• Optional – 2 plane balanced for reduced vibration (slight dimensional change and increased motor axial length).• Optional – FPS (frequency pulse signal) for tach output.• Optional – Separate V+ signal wire for input power to hall sensors in order to obtain slow speed operation.
3.29(83.57)
1.50(38.10)
2.99(75.95)
1.44(36.58)
INCH(MM)
4.42(112.21)
2.87(72.80)
1.10(27.94)
.75(19.05)
1.99(50.55)
1.40(35.56)
.25(6.35)
EXHAUST
INTAKEØ .76 (19.30) Ø .86
(21.84)
Ø .75 (19.05)
Ø .54 (13.72)
Ø 1.75 (44.45)
SQ. .78 (19.81)
2X 20.0 MIN. (508.0 MIN.)
20 GA. LEADS RED (+) BLACK (–)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
LOW
-VOL
TAGE
BLDC
BLO
WER
S
9
3.3” (84mm) BLDC Low-Voltage Blower 12/24 VDC TYPICAL PERFORMANCE
®
10
4.5” (114mm) BLDC Low-Voltage Blower 12/24 VDC
NOTES:• Temperature: Working Air: 0°C to 45°C, Ambient Air: 0°C to 45°C, Storage Air: -40°C to 85°C.• Dielectric Testing: 200 volts applied for one second between power leads and motor body, one milliamp leakage max.• Speed is controlled by varying the input voltage (there is a minimum voltage threshold, unless using the separate V+ option).• Customized performance available upon request. Please contact AMETEK Technical & Industrial Products’ Marketing and Sales Department.• When blowers are used in a vacuum condition, there will be an approximate reduction of 3% in the air performance.• Hard mounting of blower can be done by clamping around the motor’s AL casting.• 2 wire power connection (Red = positive DC, Black = negative DC).• Please observe proper polarity for power connections. Improper connection will damage the blower’s electronics.• Blower/motor is equiped with basic internal drive controller.• Optional – Motor confi guration available with connection to external controller.• Optional – 2 plane balanced for reduced vibration (slight dimensional change and increased motor axial length).• Optional – FPS (frequency pulse signal) for tach output.• Optional – Separate V+ signal wire for input power to hall sensors in order to obtain slow speed operation.
Blower Data Unit of MeasurePart Number
119494 119395
Voltage Input VDC 12 24
Stages — 1 1
Pressure, Maximum (Sealed Pressure) in. H2O, Sealed 28.3 28.3
mBar 70.4 70.4
Flow Rate, Maximum (Open Flow) CFM 9.8 9.8
m3/hr 16.7 16.7
2.12(53.8)
4.05(102.9)
4.49(114.05)
2.18(55.37)
1.53(38.86)
0.20(5.08)
1.03(26.16)
1.17(29.72)
0.57(14.48)
0.53 X 0.32(13.46 X 8.13)
OUTLET
2X 8-32 INSERT7X SCREW (FLT HD)
0.79(20.06)
2.78(70.61)
7X NUT, HEX(SELF-LOCKING)
INCH(MM)
Ø 0.60 INLET (15.20)
Ø 1.75 (44.45)
0.25 MIN. THREAD DEPTH(6.35)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
LOW
-VOL
TAGE
BLDC
BLO
WER
S
11
4.5” (114mm) BLDC Low-Voltage Blower 12/24 VDC TYPICAL PERFORMANCE
®
12
5.0” (127mm) BLDC Low-Voltage Blower 12/24 VDC, Standard Flow System
Ø .88±.03 (22.40±0.76) (EXHAUST)
Ø 1.50±.03 (38.10±0.76) (INTAKE)
Ø 5.00±.03 (127.0±0.76)
3X 0.35 (8.89)
Ø 2.50 (63.50)
58°±2°
18°±2°
46°±2°
70°±2°6°±2°
INCH(MM)
3X M5 X 0.8 THREAD HOLES .25
MIN. DP. EQUALLY SPACED
(6.35)ON A Ø 3.228 BOLT CIRCLE.
(81.99)
3X Ø .38 BOSSES (9.65)EQUALLY SPACED ON A
Ø 3.228 BOLT CIRCLE.
(81.99)
2.50±.03(63.5±0.76)
1.70±.03(43.18±0.76)
.26±.03(6.60±0.76)
(6X)
2.61±.03(66.29±0.76)
(6X)
2.06±.03(52.3±0.76)
.24±.06(6.10±1.52)
1.57±.06(39.87±1.52)
2.90±.08(73.66±2.03)
1.27±.03(32.26±0.76)
1.25±.03(31.75±0.76)
1.76±.04(44.70±1.02)MFG. NAME,
MODEL NO., AND DATE OF MFG.
OPTIONAL COVER SHELL
with AIR INLET TUBE
CONNECTOR DETAIL
MODELS 119380 THRU 119385 ARE DIMENSIONED PER THE HIGH OUTPUT VERSION
Ø BØ AGROUNDS1S2S3+5 VDCØ C
Blower Data Unit of MeasurePart Number
119380(150017)*
119381 M*119382 E*
119383(150016)*
119384 M*119385 E*
Voltage Input VDC 12 12 24 24
Stages — 1 1 1 1
Pressure, Maximum (Sealed Pressure) in. H2O 13.5 13.5 12.5 12.5
mBar 33.6 33.6 31.1 31.1
Flow Rate, Maximum (Open Flow) CFM 32.3 32.3 35.3 35.3
m3/hr 54.9 54.9 60.0 60.0
Drive Electronics Internal or External External Internal External Internal
NOTES:• Temperature: Working Air: 0°C to 45°C, Ambient Air: 0°C to 45°C, Storage Air: -40°C to 85°C.• Dielectric Testing: 500 volts AC RMS 60Hz applied for one second between input pins and ground, one milliamps leakage max.• Speed Control: Internal – E (Electrical): Pulse Width Modulated or Analog input voltage (user supplied), 0 to 5 Volts DC nominal.
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specifi c speed. External – These blowers require a 3 phase electronic commutated input to operate. A separate blower controller provides this input and
speed control. Refer to the controller section (page 118) of this catalog for additional information.• Models 119380 thru 119385 are dimensioned per the high output version - see following pages.• Customized performance available upon request. Please contact AMETEK Technical & Industrial Products’ Marketing and Sales Department.• Models 150016 and 150017 include a two (2) plane balancing option for reduced vibration per above drawing.• Models 119380 thru 119385 can be confi gured and modifi ed for a two (2) plane balance option.• When blowers are used in a vacuum condition, there will be an approximate reduction of 3% in the air performance.• Standard hard mounting is done via the three (3) mounting bosses on the motor side of the blower.• See controller section for models that require external drive electronics.• Optional – cover shell with air inlet tube.
* These part numbers are available through AMETEK Technical & Industrial Products’ distributors.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
LOW
-VOL
TAGE
BLDC
BLO
WER
S
13
5.0” (127mm) BLDC Low-Voltage Blower 12/24 VDC, Standard Flow System
TYPICAL PERFORMANCE
®
14
5.0” (127mm) BLDC Low-Voltage Blower 12/24 VDC, High Flow System
Ø 3.812±.03 (96.82±0.80)
Ø 0.88±.03 (22.40±0.76) EXHAUST
Ø 1.50±.03 (INTAKE) (38.1±0.8)
3X 0.21 (5.33)
Ø 5.00±.03 (127.0±0.80)
58°±2°
MFG. NAME, MODEL NO.,AND DATE OF MFG.
70°±2°
46°±2°
18°±2°
2.61±.03(66.29±0.76)
(6X)
.26±.03(6.60±0.76)
(6X)
2.50±.03(63.5±0.76)
1.70±.03(43.18±0.76)
2.06±.03(52.3±0.80)
1.50±.06(38.10±1.52)
2.82±.08(71.63±2.03)
1.27±.03(32.26±0.76)
1.25±.03(31.75±0.76)
.80±.06(20.32±1.52)
6°±2°
3X Ø BOSSES
EQUALLY SPACED ON A
Ø BOLT CIRCLE.
0.35(8.89)
3.228(81.99)
3X Ø X .31 DP.
HOLES EQUALLY SPACED
ON A Ø BOLT CIRCLE.
(SEE NOTE 1)
.168±.003(4.267±.076)
3.228(81.99)
INCH(MM)
INTERNAL DRIVECONNECTOR DETAIL
0-3V
GROUND
24V
OPTIONAL COVER SHELL
with AIR INLET TUBE
EXTERNAL DRIVECONNECTOR DETAIL
HALL 3
HALL 2
HALL 1
+VDC
GROUND
PHASE A
PHASE B
PHASE C
DIRECTION OF ROTATION
NOTES:• Temperature: Working Air: 0°C to 45°C, Ambient Air: 0°C to 45°C, Storage Air: -40°C to 85°C.• Dielectric Testing: 500 volts AC RMS 60Hz applied for one second between input pins and ground, one milliamps leakage max.• Speed Control: Internal – E (Electrical): Pulse Width Modulated or Analog input voltage (user supplied), 0 to 5 Volts DC nominal.
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specifi c speed. External – These blowers require a 3 phase electronic commutated input to operate. A separate blower controller provides this input and
speed control. Refer to the controller section (page 118) of this catalog for additional information.• Customized performance available upon request. Please contact AMETEK Technical & Industrial Products’ Marketing and Sales Department.• Models can be confi gured and modifi ed for a two (2) plane balance option.• When blowers are used in a vacuum condition, there will be an approximate reduction of 3% in the air performance.• Standard hard mounting is done via the three (3) mounting bosses on the motor side of the blower.• See controller section for models that require external drive electronics.• Optional – cover shell with air inlet tube.
* These part numbers are available through AMETEK Technical & Industrial Products’ distributors.
Blower Data Unit of MeasurePart Number
150166 119375 119378 M*119379 E*
Voltage Input VDC 12 24 24
Stages — 1 1 1
Pressure, Maximum (Sealed Pressure) in. H2O 20.1 24.9 24.9
mBar 50.0 62.0 62.0
Flow Rate, Maximum (Open Flow) CFM 37.7 44.6 44.6
m3/hr 64.1 75.8 75.8
Drive Electronics Internal or External Internal External Internal
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
LOW
-VOL
TAGE
BLDC
BLO
WER
S
15
5.0” (127mm) BLDC Low-Voltage Blower 12/24 VDC, High Flow System
TYPICAL PERFORMANCE
®
16
5.1” (130mm) BLDC Low-Voltage Blower 24 VDC
2.22(56.4)
2.48(63.0)
1.212(30.78) 1.71
(43.4)
0.31(7.9)
1.048(26.62)MAX.
0.27(6.9)
2.441±.040(62±1)
2X #8-32 INSERT .25 MIN FULL THREAD(6.4)
0.42 x 0.71(10.7 x18)OUTLET
2.82(71.6)
1.965 REF.(49.91)1.36
(34.5)
2.325(59.06)
Ø 0.98 (24.9)
Ø .700 INLET (17.78)
Ø 1.772 (45.0)
3X 0.38 (9.7)
4X 18.0±1.0(457.2±25.4)
PHASELEADS
RED (“C”)WHITE (“B”)BLACK (“A”)
ORANGE (GRD)YELLOW (S1)
GREEN (S2)BLUE (S3)
PURPLE (+12V)
PIN OUT & PHASE LEAD DETAILSCALE: 3:1
CAVITY #1
ROTAT ION
IN(MM)
Blower Data Unit of MeasurePart Number
150193
Voltage Input VDC 24
Stages — 1
Pressure, Maximum (Sealed Pressure) in. H2O, Sealed 50.9
mBar 126.7
Flow Rate, Maximum (Open Flow) CFM 26.3
m3/hr 44.7
NOTES: • Input Voltage: This product requires a 3 phase electronic commutated input to operate. Refer to the controller section (page 118) of this catalog for proper
controller selection. Input voltages listed in the chart above indicate the controller input voltage requirement.• Temperature: Working Air: 0°C to 45°C, Ambient Air: 0°C to 45°C, Storage Air: -40°C to 85°C.• Dielectric Testing: 200 volts applied for one second between power leads and motor body, one milliamp leakage max.• Speed Control: Via 5.0 VDC analog signal or potentiometer setting at controller.• Product includes a two (2) plane balancing option for reduced vibration.• Customized performance available upon request. Please contact AMETEK Technical & Industrial Products’ Marketing and Sales Department.• When blowers are used in a vacuum condition, there will be an approximate reduction of 3% in the air performance.• Hard mounting of blower can be done by clamping around the motor’s AL casting.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
LOW
-VOL
TAGE
BLDC
BLO
WER
S
17
5.1” (130mm) BLDC Low-Voltage Blower 24 VDC TYPICAL PERFORMANCE
®
18
5.7” (145mm) BLDC Bypass Blower24 VDC Input, Standard Flow System
NOTES:• Temperature: Working Air: 0°C to 50°C.• Dielectric Testing: 500 VDC applied for one second between input leads/wires and grounds, 3 mA leakage max.• Speed Control Input Current: Less than 1mA at 10 volts DC.• Air performance data at 24 volts DC input. Contact AMETEK for information concerning air performance at other than 24 volts DC.• Approximate Weight: 6 lbs.
Blower Data Unit of Measure Part NumberElectrical Speed Control 150400 E 150401 E 150402 E
Mechanical Speed Control 150431 M 150432 M 150433 MStages — 1 2 3
Input Voltage Range Volts DC 18 - 30 18 - 30 18 - 30
Pressure, Maximum(Sealed Pressure) at 24 VDC
In. H2O, sealed 30 56 79
mbar 74.7 139.4 196.6
Airflow, Maximum (CFM) at 24 VDC
CFM 73 65 61
m3/hr 124 110.4 103.6
Air Intake Diameter (Dimension “D1” above)
Inches 1.75 1.75 1.75
mm 44.45 44.45 44.45
Air Exhaust Diameter (Dimension “D2” above)
Inches 1.75 1.75 1.75
mm 44.45 44.45 44.45
Length (Dimension “L” above)
Inches 0.33 1.25 2.14
mm 8.38 31.75 54.36
Ø 5.88 (149.4) MAX.
Ø 2.60 MAX. (66.04)
.05 MAX. BOW(1.3) .05 MAX. BOW(1.3)
1.09(27.7)
.875±.062(22.23±1.57)
(4X)24.0±1.0
(610±25.4)
4.0±.08(101.6±2.0)2.79±.08
(70.87±2.03)
ACCESS TO SENSITIVITYADJUSTMENT FOR 0-10V DCSPEED CONTROL
B
4.66±.08(118.36±2.03)
.015/(0.38)
3.74(95.0)
45°
90°(2X)
“D2”
“D1”
“L”
B
AIRINTAKE
AIREXHAUST
#16 GA LEAD DESIGNATION
“ORANGE” LEAD: SPEED CONTROL (0-10 VDC NOMINAL)“BLUE” LEAD: TACHOUT (0-12 VDC)
#14 GA LEAD DESIGNATION
“RED” LEAD: +VIN (+24 VDC)“BLACK” LEAD: GND ( –VIN)
INCH(MM)
49°±2°
26°±2°
33°
C LSENSITIVITY
CONTROL
A
(1) Ø .168±.003 HOLE THRU (4.27±.07)LOCATED AS SHOWN ON
Ø 6.40 BOLT CIRCLE.
(162.56)
USE THIS HOLE FORGROUNDING OR EARTHING.REFER TO APPROPRIATELISTING OR REGULATORYAGENCY FOR PROPER METHOD OF GROUNDINGOR EARTHING.
2X #14 GA LEADS2X #16 GA LEADS XLPE, 300V, 125°C UL 3266/CSA 1252 SEE LEAD DESIGNATION
(3X) Ø .168±.003 HOLE THRU (4.27±.07)LOCATED AS SHOWN ON
Ø 6.50 BOLT CIRCLE.
(165.1)
Ø .024/(.61) A
SMØ.024/(.61) A
SM
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
LOW
-VOL
TAGE
BLDC
BLO
WER
S
19
5.7” (145mm) BLDC Bypass Blower24 VDC Input, Standard Flow System
TYPICAL PERFORMANCE
20
Blower Data Unit of Measure Part NumberElectrical Speed Control 150403 E 150404 E 150405 E
Mechanical Speed Control 150434 M 150435 M 150436 MFlow — High Flow High Flow Ultra High FlowStages — 1 2 1Input Voltage Range Volts DC 18 - 30 18 30 18 - 30Pressure, Maximum (Sealed Pressure) In. H2O, sealed 31 54 22
mbar 77 134 54Airflow, Maximum (CFM) CFM 125 110 190
m3/hr 212.4 186.9 322.8Air Intake Diameter (Dimension “D1” above)
Inches 1.75 1.75 2.75mm 44.45 44.45 69.85
Air Exhaust Diameter (Dimension “D2” above)
Inches 1.75 1.75 2.5mm 44.45 44.45 63.5
Length (Dimension “L” above)
Inches 0.33 1.25 0.7mm 8.38 31.75 17.78
5.7” (145mm) BLDC Bypass Blower24 VDC Input, High Flow System
Ø 5.88 (149.4) MAX.
Ø 2.60 MAX. (66.04)
.05 MAX. BOW(1.3) .05 MAX. BOW(1.3)
1.09(27.7)
.875±.062(22.23±1.57)
(4X)24.0±1.0
(610±25.4)
4.0±.08(101.6±2.0)2.79±.08
(70.87±2.03)
ACCESS TO SENSITIVITYADJUSTMENT FOR 0-10V DCSPEED CONTROL
B
4.66±.08(118.36±2.03)
.015/(0.38)
3.74(95.0)
45°
90°(2X)
“D2”
“D1”
“L”
B
AIRINTAKE
AIREXHAUST
#16 GA LEAD DESIGNATION
“ORANGE” LEAD: SPEED CONTROL (0-10 VDC NOMINAL)“BLUE” LEAD: TACHOUT (0-12 VDC)
#14 GA LEAD DESIGNATION
“RED” LEAD: +VIN (+24 VDC)“BLACK” LEAD: GND ( –VIN)
INCH(MM)
49°±2°
26°±2°
33°
C LSENSITIVITY
CONTROL
A
(1) Ø .168±.003 HOLE THRU (4.27±.07)LOCATED AS SHOWN ON
Ø 6.40 BOLT CIRCLE.
(162.56)
USE THIS HOLE FORGROUNDING OR EARTHING.REFER TO APPROPRIATELISTING OR REGULATORYAGENCY FOR PROPER METHOD OF GROUNDINGOR EARTHING.
2X #14 GA LEADS2X #16 GA LEADS XLPE, 300V, 125°C UL 3266/CSA 1252 SEE LEAD DESIGNATION
(3X) Ø .168±.003 HOLE THRU (4.27±.07)LOCATED AS SHOWN ON
Ø 6.50 BOLT CIRCLE.
(165.1)
Ø .024/(.61) M A S
SMØ.024/(.61) A
NOTES:• Temperature: Working Air: 0°C to 50°C.• Dielectric Testing: 500 VDC applied for one second between input leads/wires and grounds, 3 mA leakage max.• Speed Control Input Current: Less than 1mA at 10 volts DC.• Air performance data at 24 volts DC input. Contact AMETEK for information concerning air performance at other than 24 volts DC.• Approximate Weight: 6 lbs.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
LOW
-VOL
TAGE
BLDC
BLO
WER
S
21
5.7” (145mm) BLDC Bypass Blower24 VDC Input, High Flow System
TYPICAL PERFORMANCE
22
Blower Data Unit of Measure Part NumberElectrical Speed Control 150406 E 150407 E
Mechanical Speed Control 150437 M 150438 MStages — 1 2Input Voltage Range Volts DC 18 – 30 18 – 30Pressure, Maximum (Sealed Pressure)
In. H2O 36 66
mbar 91 164Airflow, Maximum CFM 79 75
m3/hr 134.2 127.4Air Intake Diameter (Dimension “D1” above)
Inches 1.75 1.75mm 44.45 44.45
Air Exhaust Diameter (Dimension “D2” above)
Inches 1.75 1.75mm 44.45 44.45
Length(Dimension “L” above)
Inches 0.74 1.6mm 18.8 40.64
5.7” (145mm) BLDC Thru Flow Blower24 VDC Input, Standard Flow System
Ø 0.58 (14.73) (3X)
Ø 5.88 (149.4) MAX.
.120 MAX. BOW OUT (3.05)
1.04(26.42)
3.74(95.0)
1.47(37.3)
(4X)14.88±1.00 (378±25.4)
.875±.062(22.23±1.57)
2.47±.03(62.74±.76)
.015/(.38)
“L”
“A”
INCH(MM)
2X #14 GA LEADS2X #16 GA LEADS XLPE, 300V, 125°C UL 3266/CSA 1252 SEE LEAD DESIGNATION
(1) Ø .168±.003 HOLE THRU, (4.27±.07)LOCATED AS SHOWN ON
Ø 6.40 BOLT CIRCLE.
(162.56)
USE THIS HOLE FOR GROUNDING OR EARTHING. REFER TO APPROPRIATE LISTING OR REGULATORY AGENCY FOR PROPER METHOD OF GROUNDINGOR EARTHING.
SMØ.034/(.86) A
33°
30°±3°
#16 GA LEAD DESIGNATION
“ORANGE” LEAD: SPEED CONTROL (0-10 VDC NOMINAL“BLUE” LEAD: TACHOUT (0-12 VDC)
#14 GA LEAD DESIGNATION
“RED” LEAD: +VIN (+24 VDC)“BLACK” LEAD: GND ( –VIN)
AIRINTAKE
AIREXHAUST
(3X) Ø .168±.003 HOLE (4.27±.07)
THRU LOCATED AS SHOWN
ON A Ø 6.50 BOLT CIRCLE.
(165.10)SMØ.034/(.86) A 90°
(2X)45°
“D2”
“D1”
NOTES:• Temperature: Working Air: 0°C to 50°C.• Dielectric Testing: 500 VDC applied for one second between input leads/wires and grounds, 3 mA leakage max.• Speed Control Input Current: Less than 1mA at 10 volts DC.• Air performance data at 24 volts DC input. Contact AMETEK for information concerning air performance at other than 24 volts DC.• Approximate Weight: 6 lbs.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
LOW
-VOL
TAGE
BLDC
BLO
WER
S
23
5.7” (145mm) BLDC Thru Flow Blower24 VDC Input, Standard Flow System
TYPICAL PERFORMANCE
24
Blower Data Unit of Measure Part Number Electrical Speed Control 150409 E 150410 E
Mechanical Speed Control 150439 M 150440 MStages — 1 2Input Voltage Range Volts DC 18 – 30 18 - 30Pressure, Maximum (Sealed Pressure) In. H2O 33 57
mbar 82 143Airflow, Maximum CFM 123 112
m3/hr 209 190.3Air Intake Diameter (Dimension “D1” above)
Inches 1.75 1.75mm 44.45 44.45
Air Exhaust Diameter (Dimension “D2” above)
Inches 1.75 1.75mm 44.45 44.45
Length(Dimension “L” above)
Inches 0.76 1.81mm 19.3 45.97
5.7” (145mm) BLDC Thru Flow Blower24 VDC Input, High Flow System
Ø 0.58 (14.73) (3X)
Ø 5.88 (149.4) MAX.
.120 MAX. BOW OUT (3.05)
1.04(26.42)
3.74(95.0)
1.47(37.3)
(4X)14.88±1.00 (378±25.4)
.875±.062(22.23±1.57)
2.47±.03(62.74±.76)
.015/(.38)
“L”
“A”
INCH(MM)
2X #14 GA LEADS2X #16 GA LEADS XLPE, 300V, 125°C UL 3266/CSA 1252 SEE LEAD DESIGNATION
(1) Ø .168±.003 HOLE THRU, (4.27±.07)LOCATED AS SHOWN ON
Ø 6.40 BOLT CIRCLE.
(162.56)
USE THIS HOLE FOR GROUNDING OR EARTHING. REFER TO APPROPRIATE LISTING OR REGULATORY AGENCY FOR PROPER METHOD OF GROUNDINGOR EARTHING.
SMØ.034/(.86) A
33°
30°±3°
#16 GA LEAD DESIGNATION
“ORANGE” LEAD: SPEED CONTROL (0-10 VDC NOMINAL“BLUE” LEAD: TACHOUT (0-12 VDC)
#14 GA LEAD DESIGNATION
“RED” LEAD: +VIN (+24 VDC)“BLACK” LEAD: GND ( –VIN)
AIRINTAKE
AIREXHAUST
(3X) Ø .168±.003 HOLE (4.27±.07)
THRU LOCATED AS SHOWN
ON A Ø 6.50 BOLT CIRCLE.
(165.10)SMØ.034/(.86) A 90°
(2X)45°
“D2”
“D1”
NOTES:• Temperature: Working Air: 0°C to 50°C.• Dielectric Testing: 500 VDC applied for one second between input leads/wires and grounds, 3 mA leakage max.• Speed Control Input Current: Less than 1mA at 10 volts DC.• Air performance data at 24 volts DC input. Contact AMETEK for information concerning air performance at other than 24 volts DC.• Approximate Weight: 6 lbs.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
LOW
-VOL
TAGE
BLDC
BLO
WER
S
25
5.7” (145mm) BLDC Thru Flow Blower24 VDC Input, High Flow System
TYPICAL PERFORMANCE
26
Blower Data Unit of Measure Part NumberElectrical Speed Control 150411 E 150412 E 150413 E
Mechanical Speed Control 150441 M 150442 M 150443 MStages — 1 2 3Input Voltage Range Volts DC 36 – 60 VDC 36 – 60 VDC 36 – 60 VDCPressure, Maximum (Sealed Pressure) In. H2O, sealed 28.1 52.7 73.15
mbar 69.8 130.6 181.4Airflow, Maximum (CFM) CFM 71 59 56
m3/hr 120.6 100.2 95.1Diameter Inlet (Dimension “D1” above)
Inches 1.75 1.75 1.75mm 44.45 44.45 44.45
Diameter Outlet (Dimension “D2” above)
Inches 1.75 1.75 1.75mm 44.45 44.45 44.45
Length (Dimension “L” above)
Inches 0.33 1.25 2.14mm 8.38 31.75 54.36
5.7” (145mm) BLDC Bypass Blower48 VDC Input, Standard Flow System
INCH(MM)
12 3
4 5
12345
Ø 2.60 MAX. (66.0)Ø 5.88 (149.4) MAX.
2.79±.08(70.87±2.03)
3.29±.06(83.57±1.52) 7.50±1.00
(190.50±25.40)
.875±.062(22.23±1.57)
4.66±.08(118.36±2.03)
SEE NOTE 3 & 4TO BLOWER
1.38(35.05)REF.
B
2.40(60.97)
1.09(27.7)
49°±2° 26°±2° 33°90°(2X)
3.74(95.0)
45°
SEE DETAIL “A”
“B”
AIREXHAUST
AIRINTAKE
VIEW “B”DETAIL “A”
HARNESS ASSEMBLY
ACCESS TOSENSITIVITYADJUSTMENTFOR 0-10V DCSPEED CONTROL(REF. PINCONNECTION)
(1) Ø .168±.003 HOLE THRU (4.27±.07)LOCATED AS SHOWN ON
Ø 6.40 BOLT CIRCLE.
(162.56)
USE THIS HOLE FORGROUNDING OR EARTHING.REFER TO APPROPRIATELISTING OR REGULATORYAGENCY FOR PROPER METHOD OF GROUNDINGOR EARTHING.
SMØ.024/(.61) A
C LSENSITIVITY
CONTROL
LOW (–) } ISOLATED SPEEDHIGH (+) CONTROL INPUT
GROUND ( )– DC INPUT VOLTAGE+ DC INPUT VOLTAGE
.05 MAX. BOW(1.3) .05 MAX. BOW(1.3)
“D2”A
“D1”
(3X) Ø .168±.003 HOLE THRU (4.27±.07)LOCATED AS SHOWN ON
Ø 6.50 BOLT CIRCLE.
(165.1)
Ø .024/(.61) A SM.015/(0.38)B
NOTES:• Amp Mate-n-Lok connector (PN 350810-1) using Amp sockets (PN 350536-1) mates with customer supplied Amp Mate-n-Lok connector housing
(PN 350809-1), using Amp (PN 350561-1) pin terminals.• Temperature: Vent Inlet Air: 0°C to 50°C.• Isolated Speed Control:
Analog Input Voltage Range: 2.2 to +10 VDC nominal, (+15 VDC maximum). Digital Pulse Input: 400 Hz to 20 KHz, 1 to +10 Volt pulse nominal, minimum duty cycle 10%, 0 to +12 Volt maximum.Note: Setting of potentiometer can affect control voltage range and maximum speed can be reached before reaching 10 VDC.
• Speed Control Input Current: Less than 20 mA at 10 Volts input with multi turn internal potentiometer set to minimum (fully counter-clockwise).• Speed Control Drift with Temperature:
Analog Mode: Typ. ±4% from nominal speed at +23°C.Digital or Direct Mode: Typ. ±4% from nominal speed at +23°C.
• Operating Temperature: 0°C to 50°C.• Storage Temperature: -40°C to 85°C.• Dielectric Testing: 500 VDC applied for one second between input leads/wires and ground, 3mA leakage max.• Air performance data is at 48 volts DC input. Contact AMETEK for information concerning air performance at other than 48 volts DC.• Approximate Weight: 6 lbs.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
LOW
-VOL
TAGE
BLDC
BLO
WER
S
27
5.7” (145mm) BLDC Bypass Blower48 VDC Input, Standard Flow System
TYPICAL PERFORMANCE
28
Blower Data Unit of Measure Part NumberElectrical Speed Control 150414 E 150415 E 150416 E
Mechanical Speed Control 150444 M 150445 M 150446 MFan System — High Airflow High Airflow Ultra High FlowStages — 1 2 1Input Voltage Range Volts DC 36 - 60 36 - 60 36 - 60Pressure, Maximum (Sealed Pressure) at 48 VDC
In. H2O, sealed 29.5 51.5 21.1
mbar 73.1 127.7 52.5Airflow, Maximum (CFM) at 48 VDC
CFM 115.7 91.3 160.3m3/hr 196.6 155.1 272.4
Diameter Inlet (Dimension “D1” above)
Inches 1.75 1.75 2.75mm 44.45 44.45 68.85
Diameter Outlet (Dimension “D2” above)
Inches 1.75 1.75 2.5mm 44.45 44.45 63.5
Length (Dimension “L” above)
Inches 0.47 1.53 0.71mm 11.94 38.86 18.03
5.7” (145mm) BLDC Bypass Blower48 VDC Input, High Flow System
INCH(MM)
12 3
4 5
12345
Ø 2.60 MAX. (66.0)Ø 5.88 (149.4) MAX.
2.79±.08(70.87±2.03)
3.29±.06(83.57±1.52) 7.50±1.00
(190.50±25.40)
.875±.062(22.23±1.57)
4.66±.08(118.36±2.03)
SEE NOTE 3 & 4TO BLOWER
1.38(35.05)REF.
B
2.40(60.97)
1.09(27.7)
49°±2° 26°±2° 33°90°(2X)
3.74(95.0)
45°
SEE DETAIL “A”
“B”
AIREXHAUST
AIRINTAKE
VIEW “B”DETAIL “A”
HARNESS ASSEMBLY
ACCESS TOSENSITIVITYADJUSTMENTFOR 0-10V DCSPEED CONTROL(REF. PINCONNECTION)
(1) Ø .168±.003 HOLE THRU (4.27±.07)LOCATED AS SHOWN ON
Ø 6.40 BOLT CIRCLE.
(162.56)
USE THIS HOLE FORGROUNDING OR EARTHING.REFER TO APPROPRIATELISTING OR REGULATORYAGENCY FOR PROPER METHOD OF GROUNDINGOR EARTHING.
SMØ.024/(.61) A
C LSENSITIVITY
CONTROL
LOW (–) } ISOLATED SPEEDHIGH (+) CONTROL INPUT
GROUND ( )– DC INPUT VOLTAGE+ DC INPUT VOLTAGE
.05 MAX. BOW(1.3) .05 MAX. BOW(1.3)
“D2”A
“D1”
(3X) Ø .168±.003 HOLE THRU (4.27±.07)LOCATED AS SHOWN ON
Ø 6.50 BOLT CIRCLE.
(165.1)
Ø .024/(.61) A SM.015/(0.38)B
NOTES:• Amp Mate-n-Lok connector (PN 350810-1) using Amp sockets (PN 350536-1) mates with customer supplied Amp Mate-n-Lok connector housing
(PN 350809-1), using Amp (PN 350561-1) pin terminals.• Temperature: Vent Inlet Air: 0°C to 50°C.• Isolated Speed Control:
Analog Input Voltage Range: 2.2 to +10 VDC nominal, (+15 VDC maximum). Digital Pulse Input: 400 Hz to 20 KHz, 1 to +10 Volt pulse nominal, minimum duty cycle 10%, 0 to +12 Volt maximum.Note: Setting of potentiometer can affect control voltage range and maximum speed can be reached before reaching 10 VDC.
• Speed Control Input Current: Less than 20 mA at 10 Volts input with multi turn internal potentiometer set to minimum (fully counter-clockwise).• Speed Control Drift with Temperature:
Analog Mode: Typ. ±4% from nominal speed at +23°C.Digital or Direct Mode: Typ. ±4% from nominal speed at +23°C.
• Operating Temperature: 0°C to 50°C.• Storage Temperature: -40°C to 85°C.• Dielectric Testing: 500 VDC applied for one second between input leads/wires and ground, 3mA leakage max.• Air performance data is at 48 volts DC input. Contact AMETEK for information concerning air performance at other than 48 volts DC.• Approximate Weight: 6 lbs.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
LOW
-VOL
TAGE
BLDC
BLO
WER
S
29
5.7” (145mm) BLDC Bypass Blower48 VDC Input, High Flow System
TYPICAL PERFORMANCE
30
NOTES:• Amp Mate-n-Lok connector (PN 350810-1) using Amp sockets (PN 350536-1) mates with customer supplied Amp Mate-n-Lok connector housing
(PN 350809-1), using Amp (PN 350561-1) pin terminals.• Temperature: Vent Inlet Air: 0°C to 50°C.• Isolated Speed Control:
Analog Input Voltage Range: 2.2 to +10 VDC nominal, (+15 VDC maximum). Digital Pulse Input: 400 Hz to 20 KHz, 1 to +10 Volt pulse nominal, minimum duty cycle 10%, 0 to +12 Volt maximum.Note: Setting of potentiometer can affect control voltage range and maximum speed can be reached before reaching 10 VDC.
• Speed Control Input Current: Less than 20 mA at 10 Volts input with multi turn internal potentiometer set to minimum (fully counter-clockwise).• Speed Control Drift with Temperature:
Analog Mode: Typ. ±4% from nominal speed at +23°C.Digital or Direct Mode: Typ. ±4% from nominal speed at +23°C.
• Operating Temperature: 0°C to 50°C.• Storage Temperature: -40°C to 85°C.• Dielectric Testing: 500 VDC applied for one second between input leads/wires and ground, 3mA leakage max.• Air performance data is at 48 volts DC input. Contact AMETEK for information concerning air performance at other than 48 volts DC.• Approximate Weight: 6 lbs.
Blower Data Unit of Measure Part NumberElectrical Speed Control 150417 E 150129 E 150418 E
Mechanical Speed Control 150447 M 150461 M 150448 MStages — 1 2 3Input Voltage Range Volts DC 36 - 60 36 - 60 36 - 60Pressure, Maximum (Sealed Pressure)
In. H2O, sealed 41.5 71.8 82.5
mbar 103 178.1 204.6Airflow, Maximum (CFM) CFM 80.5 65.9 56.4
m3/hr 136.8 112 95.8Air Intake Diameter (Dimension “D1” above)
Inches 1.75 1.75 1.75mm 44.45 44.45 44.45
Air Exhaust Diameter (Dimension “D2” above)
Inches 1.75 1.75 1.75mm 44.45 44.45 44.45
Length (Dimension “L” above)
Inches 0.74 1.6 2.58mm 18.8 40.64 65.53
5.7” (145mm) BLDC Thru Flow Blower48 VDC Input, Standard Flow System
Ø .58 (14.73) (3X)
Ø 5.88 (149.4) MAX.
1.04(26.42) 90°
(2X)
20°±2°
3.74(95.0)
45°
.45±.06(11.43±1.52)
SEE DETAIL “B” POST HEADERASSEMBLY
CUSTOMER WIRING HARNESS WITH AMP CONNECTOR
INCH(MM)
33°
(1) Ø .168±.003 HOLE THRU (4.27±.07)LOCATED AS SHOWN ON Ø 6.40 BOLT CIRCLE. (162.56)
USE THIS HOLE FOR GROUNDING OR EARTHING. REFER TO APPROPRIATE LISTING OR REGULATORY AGENCY FOR PROPER METHOD OF GROUNDING OR EARTHING.
SMØ.034/(.86) A
2.47±.03(62.74±.76)
.875±.062(22.23±1.57)
3.38±.08(85.85±2.03)
.015 / (.38)
“L”
.120 MAX. BOW OUT(3.05)
AIREXHAUST
AIRINTAKE
(3X) Ø .168±.003 HOLE THRU (4.27±.07)LOCATED AS SHOWN ON
Ø 6.50 BOLT CIRCLE.
(165.1)
Ø .034/(.86) A SM
“D2”
“D1”
#1
1 2 3 4 5
#5
LOW (NEGATIVE)
HIGH (POSITIVE)
NOT USED, KEYINGPLUG IN HOLE
+DC INPUT VOLTAGE: 32-64V ± 10%
– DC INPUT VOLTAGE: 32-64V ± 10%
ISOLATED SPEEDCONTROL0-10 VDC
INPUT REQUIRED{
DETAIL “B”POSTER HEADER ASSEMBLY
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
LOW
-VOL
TAGE
BLDC
BLO
WER
S
31
5.7” (145mm) BLDC Thru Flow Blower48 VDC Input, Standard Flow System
TYPICAL PERFORMANCE
32
NOTES:• Amp Mate-n-Lok connector (PN 350810-1) using Amp sockets (PN 350536-1) mates with customer supplied Amp Mate-n-Lok connector housing
(PN 350809-1), using Amp (PN 350561-1) pin terminals.• Temperature: Vent Inlet Air: 0°C to 50°C.• Isolated Speed Control:
Analog Input Voltage Range: 2.2 to +10 VDC nominal, (+15 VDC maximum). Digital Pulse Input: 400 Hz to 20 KHz, 1 to +10 Volt pulse nominal, minimum duty cycle 10%, 0 to +12 Volt maximum.Note: Setting of potentiometer can affect control voltage range and maximum speed can be reached before reaching 10 VDC.
• Speed Control Input Current: Less than 20 mA at 10 Volts input with multi turn internal potentiometer set to minimum (fully counter-clockwise).• Speed Control Drift with Temperature:
Analog Mode: Typ. ±4% from nominal speed at +23°C.Digital or Direct Mode: Typ. ±4% from nominal speed at +23°C.
• Operating Temperature: 0°C to 50°C.• Storage Temperature: -40°C to 85°C.• Dielectric Testing: 500 VDC applied for one second between input leads/wires and ground, 3mA leakage max.• Air performance data is at 48 volts DC input. Contact AMETEK for information concerning air performance at other than 48 volts DC.• Approximate Weight: 6 lbs.
Blower Data Unit of Measure Part NumberElectrical Speed Control 150419 E 150420 E
Mechanical Speed Control 150449 M 150450 MStages — 1 2Input Voltage Range Volts DC 36 – 60 VDC 36 – 60 VDCPressure, Maximum (Sealed Pressure) In. H2O, sealed 37.9 53
mbar 94.1 131.5Airflow, Maximum (CFM) CFM 102.8 85.9
m3/hr 174.7 145.9Air Intake Diameter (Dimension “D1” above)
Inches 1.75 1.75mm 44.5 44.5
Air Intake Exhaust (Dimension “D2” above)
Inches 1.75 1.75mm 44.5 44.5
Length (Dimension “L” above)
Inches 0.76 1.81mm 19.3 45.9
5.7” (145mm) BLDC Thru Flow Blower48 VDC Input, High Flow System
Ø .58 (14.73) (3X)
Ø 5.88 (149.4) MAX.
1.04(26.42) 90°
(2X)
20°±2°
3.74(95.0)
45°
.45±.06(11.43±1.52)
SEE DETAIL “B” POST HEADERASSEMBLY
CUSTOMER WIRING HARNESS WITH AMP CONNECTOR
INCH(MM)
33°
(1) Ø .168±.003 HOLE THRU (4.27±.07)LOCATED AS SHOWN ON Ø 6.40 BOLT CIRCLE. (162.56)
USE THIS HOLE FOR GROUNDING OR EARTHING. REFER TO APPROPRIATE LISTING OR REGULATORY AGENCY FOR PROPER METHOD OF GROUNDING OR EARTHING.
SMØ.034/(.86) A
2.47±.03(62.74±.76)
.875±.062(22.23±1.57)
3.38±.08(85.85±2.03)
.015 / (.38)
“L”
.120 MAX. BOW OUT(3.05)
AIREXHAUST
AIRINTAKE
(3X) Ø .168±.003 HOLE THRU (4.27±.07)LOCATED AS SHOWN ON
Ø 6.50 BOLT CIRCLE.
(165.1)
Ø .034/(.86) A SM
“D2”
“D1”
#1
1 2 3 4 5
#5
LOW (NEGATIVE)
HIGH (POSITIVE)
NOT USED, KEYINGPLUG IN HOLE
+DC INPUT VOLTAGE: 32-64V ± 10%
– DC INPUT VOLTAGE: 32-64V ± 10%
ISOLATED SPEEDCONTROL0-10 VDC
INPUT REQUIRED{
DETAIL “B”POSTER HEADER ASSEMBLY
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
LOW
-VOL
TAGE
BLDC
BLO
WER
S
33
5.7” (145mm) BLDC Thru Flow Blower48 VDC Input, High Flow System
TYPICAL PERFORMANCE
34
NOTES:• Amp Mate-n-Lok connector (PN 350810-1) using Amp sockets (PN 350536-1) mates with customer supplied Amp Mate-n-Lok connector housing
(PN 350809-1), using Amp (PN 350561-1) pin terminals.• Temperature: Vent Inlet Air: 0°C to 50°C.• Isolated Speed Control:
Analog Input Voltage Range: 2.2 to +10 VDC nominal, (+15 VDC maximum). Digital Pulse Input: 400 Hz to 20 KHz, 1 to +10 Volt pulse nominal, minimum duty cycle 10%, 0 to +12 Volt maximum.Note: Setting of potentiometer can affect control voltage range and maximum speed can be reached before reaching 10 VDC.
• Speed Control Input Current: Less than 20 mA at 10 Volts input with multi turn internal potentiometer set to minimum (fully counter-clockwise).• Speed Control Drift with Temperature:
Analog Mode: Typ. ±4% from nominal speed at +23°C.Digital or Direct Mode: Typ. ±4% from nominal speed at +23°C.
• Operating Temperature: 0°C to 50°C.• Storage Temperature: -40°C to 85°C.• Dielectric Testing: 500 VDC applied for one second between input leads/wires and ground, 3mA leakage max.• Air performance data is at 72 volts DC input. Contact AMETEK for information concerning air performance at other than 72 volts DC.• Approximate Weight: 6 lbs.
Blower Data Unit of Measure Part NumberElectrical Speed Control 150421 E 150422 E 150423 E
Mechanical Speed Control 150451 M 150452 M 150453 MStages — 1 2 3Input Voltage Range Volts DC 54 - 90 54 - 90 54 - 90Pressure, Maximum (Sealed Pressure) In. H2O, sealed 39.3 73.6 88.3
mbar 97.4 182.4 218.9Airflow, Maximum (CFM) CFM 82 65.2 56.4
m3/hr 139.3 110.8 95.8Diameter Inlet (Dimension “D1” above)
Inches 1.75 1.75 1.75mm 44.45 44.45 44.45
Diameter Outlet (Dimension “D2” above)
Inches 1.75 1.75 1.75mm 44.45 44.45 44.45
Length (Dimension “L” above)
Inches 0.33 1.25 2.14mm 8.38 31.75 54.36
5.7” (145mm) BLDC Bypass Blower72 VDC Input, Standard Flow System
INCH(MM)
12 3
4 5
12345
Ø 2.60 MAX. (66.0)Ø 5.88 (149.4) MAX.
2.79±.08(70.87±2.03)
3.29±.06(83.57±1.52) 7.50±1.00
(190.50±25.40)
.875±.062(22.23±1.57)
4.66±.08(118.36±2.03)
SEE NOTE 3 & 4TO BLOWER
1.38(35.05)REF.
B
2.40(60.97)
1.09(27.7)
49°±2° 26°±2° 33°90°(2X)
3.74(95.0)
45°
SEE DETAIL “A”
“B”
AIREXHAUST
AIRINTAKE
VIEW “B”DETAIL “A”
HARNESS ASSEMBLY
ACCESS TOSENSITIVITYADJUSTMENTFOR 0-10V DCSPEED CONTROL(REF. PINCONNECTION)
(1) Ø .168±.003 HOLE THRU (4.27±.07)LOCATED AS SHOWN ON
Ø 6.40 BOLT CIRCLE.
(162.56)
USE THIS HOLE FORGROUNDING OR EARTHING.REFER TO APPROPRIATELISTING OR REGULATORYAGENCY FOR PROPER METHOD OF GROUNDINGOR EARTHING.
SMØ.024/(.61) A
C LSENSITIVITY
CONTROL
LOW (–) } ISOLATED SPEEDHIGH (+) CONTROL INPUT
GROUND ( )– DC INPUT VOLTAGE+ DC INPUT VOLTAGE
.05 MAX. BOW(1.3) .05 MAX. BOW(1.3)
“D2”A
“D1”
(3X) Ø .168±.003 HOLE THRU (4.27±.07)LOCATED AS SHOWN ON
Ø 6.50 BOLT CIRCLE.
(165.1)
Ø .024/(.61) A SM.015/(0.38)B
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
LOW
-VOL
TAGE
BLDC
BLO
WER
S
35
5.7” (145mm) BLDC Bypass Blower72 VDC Input, Standard Flow System
TYPICAL PERFORMANCE
36
NOTES:• Amp Mate-n-Lok connector (PN 350810-1) using Amp sockets (PN 350536-1) mates with customer supplied Amp Mate-n-Lok connector housing
(PN 350809-1), using Amp (PN 350561-1) pin terminals.• Temperature: Vent Inlet Air: 0°C to 50°C.• Isolated Speed Control:
Analog Input Voltage Range: 2.2 to +10 VDC nominal, (+15 VDC maximum). Digital Pulse Input: 400 Hz to 20 KHz, 1 to +10 Volt pulse nominal, minimum duty cycle 10%, 0 to +12 Volt maximum.Note: Setting of potentiometer can affect control voltage range and maximum speed can be reached before reaching 10 VDC.
• Speed Control Input Current: Less than 20 mA at 10 Volts input with multi turn internal potentiometer set to minimum (fully counter-clockwise).• Speed Control Drift with Temperature:
Analog Mode: Typ. ±4% from nominal speed at +23°C.Digital or Direct Mode: Typ. ±4% from nominal speed at +23°C.
• Operating Temperature: 0°C to 50°C.• Storage Temperature: -40°C to 85°C.• Dielectric Testing: 500 VDC applied for one second between input leads/wires and ground, 3mA leakage max.• Air performance data is at 72 volts DC input. Contact AMETEK for information concerning air performance at other than 72 volts DC.• Approximate Weight: 6 lbs.
Blower Data Unit of Measure Part NumberElectrical Speed Control 150424 E 150425 E 150426 E
Mechanical Speed Control 150454 M 150455 M 150456 MFan System — High Flow High Flow Ultrahigh FlowStages — 1 2 1Input Voltage Range Volts DC 72 72 72Pressure, Maximum(Sealed Pressure)
In. H2O, sealed 42.7 59.1 25
mbar 105.9 146.6 61.9Airflow, Maximum(CFM)
CFM 123.6 93.6 159.3m3/hr 210 159 270.7
Diameter Inlet (Dimension “D1” above)
Inches 1.75 1.75 2.75mm 44.45 44.45 68.85
Diameter Outlet (Dimension “D2” above)
Inches 1.75 1.75 2.5mm 44.45 44.45 63.5
Length (Dimension “L” above)
Inches 0.47 1.53 0.71mm 11.94 38.86 18.03
5.7” (145mm) BLDC Bypass Blower72 VDC Input, High Flow System
INCH(MM)
12 3
4 5
12345
Ø 2.60 MAX. (66.0)Ø 5.88 (149.4) MAX.
2.79±.08(70.87±2.03)
3.29±.06(83.57±1.52) 7.50±1.00
(190.50±25.40)
.875±.062(22.23±1.57)
4.66±.08(118.36±2.03)
SEE NOTE 3 & 4TO BLOWER
1.38(35.05)REF.
B
2.40(60.97)
1.09(27.7)
49°±2° 26°±2° 33°90°(2X)
3.74(95.0)
45°
SEE DETAIL “A”
“B”
AIREXHAUST
AIRINTAKE
VIEW “B”DETAIL “A”
HARNESS ASSEMBLY
ACCESS TOSENSITIVITYADJUSTMENTFOR 0-10V DCSPEED CONTROL(REF. PINCONNECTION)
(1) Ø .168±.003 HOLE THRU (4.27±.07)LOCATED AS SHOWN ON
Ø 6.40 BOLT CIRCLE.
(162.56)
USE THIS HOLE FORGROUNDING OR EARTHING.REFER TO APPROPRIATELISTING OR REGULATORYAGENCY FOR PROPER METHOD OF GROUNDINGOR EARTHING.
SMØ.024/(.61) A
C LSENSITIVITY
CONTROL
LOW (–) } ISOLATED SPEEDHIGH (+) CONTROL INPUT
GROUND ( )– DC INPUT VOLTAGE+ DC INPUT VOLTAGE
.05 MAX. BOW(1.3) .05 MAX. BOW(1.3)
“D2”A
“D1”
(3X) Ø .168±.003 HOLE THRU (4.27±.07)LOCATED AS SHOWN ON
Ø 6.50 BOLT CIRCLE.
(165.1)
Ø .024/(.61) A SM.015/(0.38)B
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
LOW
-VOL
TAGE
BLDC
BLO
WER
S
37
5.7” (145mm) BLDC Bypass Blower72 VDC Input, High Flow System
TYPICAL PERFORMANCE
38
NOTES:• Contact AMETEK for information concerning models that operate over the 12 VDC - 50 VDC input range.• Temperature: Working Air: 0°C to 50°C.• Isolated Speed Control:
Analog Input Voltage Range: 2.2 to +10 VDC nominal, (+15 VDC maximum). Digital Pulse Input: 400 Hz to 20 KHz, 1 to +10 Volt pulse nominal, minimum duty cycle 10%, 0 to +12 Volt maximum.Note: Setting of potentiometer can affect control voltage range and maximum speed can be reached before reaching 10 VDC.
• Speed Control Input Current: Less than 20 mA at 10 Volts input with multi turn internal potentiometer set to minimum (fully counter-clockwise).• Speed Control Drift with Temperature:
Analog Mode: Typ. ±4% from nominal speed at +23°C.Digital or Direct Mode: Typ. ±4% from nominal speed at +23°C.
• Operating Temperature: 0°C to 50°C.• Storage Temperature: -40°C to 85°C.• Dielectric Testing: 500 VDC applied for one second between input leads/wires and ground, 3mA leakage max.• Air performance data is at 72 volts DC input. Contact AMETEK for information concerning air performance at other than 72 volts DC. • Approximate Weight: 6 lbs.
Blower Data Unit of Measure Part NumberElectrical Speed Control 150427 E 150128 E 150428 E
Mechanical Speed Control 150457 M 150462 M 150458 MStages — 1 2 3Input Voltage Range Volts DC 72 72 72Pressure, Maximum (Sealed Pressure)
In. H2O, sealed 35.8 72.1 97.7
mbar 88.7 178.9 242.4Airflow, Maximum (CFM) CFM 85.5 74.7 63.5
m3/hr 145.3 126.9 107.9Air Intake Diameter (Dimension “D1” above)
Inches 1.25 1.25 1.25mm 31.75 31.75 31.75
Air Exhaust Diameter (Dimension “D2” above)
Inches 1.25 1.25 1.25mm 31.75 31.75 31.75
Length (Dimension “L” above)
Inches 0.74 1.6 2.58mm 18.8 40.64 65.53
5.7” (145mm) BLDC Thru Flow Blower72 VDC Input, Standard Flow System
Ø .58 (14.73) (3X)
Ø 5.88 (149.4) MAX.
1.04(26.42) 90°
(2X)
20°±2°
3.74(95.0)
45°
.45±.06(11.43±1.52)
SEE DETAIL “B” POST HEADERASSEMBLY
CUSTOMER WIRING HARNESS WITH AMP CONNECTOR
INCH(MM)
33°
(1) Ø .168±.003 HOLE THRU (4.27±.07)LOCATED AS SHOWN ON Ø 6.40 BOLT CIRCLE. (162.56)
USE THIS HOLE FOR GROUNDING OR EARTHING. REFER TO APPROPRIATE LISTING OR REGULATORY AGENCY FOR PROPER METHOD OF GROUNDING OR EARTHING.
SMØ.034/(.86) A
2.47±.03(62.74±.76)
.875±.062(22.23±1.57)
3.38±.08(85.85±2.03)
.015 / (.38)
“L”
.120 MAX. BOW OUT(3.05)
AIREXHAUST
AIRINTAKE
(3X) Ø .168±.003 HOLE THRU (4.27±.07)LOCATED AS SHOWN ON
Ø 6.50 BOLT CIRCLE.
(165.1)
Ø .034/(.86) A SM
“D2”
“D1”
#1
1 2 3 4 5
#5
LOW (NEGATIVE)
HIGH (POSITIVE)
NOT USED, KEYINGPLUG IN HOLE
+DC INPUT VOLTAGE: 32-64V ± 10%
– DC INPUT VOLTAGE: 32-64V ± 10%
ISOLATED SPEEDCONTROL0-10 VDC
INPUT REQUIRED{
DETAIL “B”POSTER HEADER ASSEMBLY
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
LOW
-VOL
TAGE
BLDC
BLO
WER
S
39
5.7” (145mm) BLDC Thru Flow Blower72 VDC Input, Standard Flow System
TYPICAL PERFORMANCE
40
NOTES:• Amp Mate-n-Lok connector (PN 350810-1) using Amp sockets (PN 350536-1) mates with customer supplied Amp Mate-n-Lok connector housing
(PN 350809-1), using Amp (PN 350561-1) pin terminals.• Temperature: Working Air: 0°C to 50°C.• Isolated Speed Control:
Analog Input Voltage Range: 2.2 to +10 VDC nominal, (+15 VDC maximum). Digital Pulse Input: 400 Hz to 20 KHz, 1 to +10 Volt pulse nominal, minimum duty cycle 10%, 0 to +12 Volt maximum.Note: Setting of potentiometer can affect control voltage range and maximum speed can be reached before reaching 10 VDC.
• Speed Control Input Current: Less than 20 mA at 10 Volts input with multi turn internal potentiometer set to minimum (fully counter-clockwise).• Speed Control Drift with Temperature:
Analog Mode: Typ. ±4% from nominal speed at +23°C.Digital or Direct Mode: Typ. ±4% from nominal speed at +23°C.
• Operating Temperature: 0°C to 50°C.• Storage Temperature: -40°C to 85°C.• Dielectric Testing: 500 VDC applied for one second between input leads/wires and ground, 3mA leakage max.• Air performance data is at 72 volts DC input. Contact AMETEK for information concerning air performance at other than 72 volts DC.• Approximate Weight: 6 lbs.
Blower Data Unit of Measure Part NumberElectrical Speed Control 150429 E 150430 E
Mechanical Speed Control 150459 M 150460 MStages — 1 2Input Voltage Range Volts DC 72 72Pressure, Maximum (Sealed Pressure)
In. H2O, sealed 37.9 65.8
mbar 94 163.2Airflow, Maximum (CFM) CFM 118.9 95.2
m3/hr 202 161.7Air Intake Diameter(Dimension “D1” above)
Inches 1.75 1.75mm 44.5 44.5
Air Intake Exhaust(Dimension “D2” above)
Inches 1.75 1.75mm 44.5 44.5
Length (Dimension “L” above)
Inches 0.76 1.81mm 19.3 45.9
5.7” (145mm) BLDC Thru Flow Blower72 VDC Input, High Flow System
Ø .58 (14.73) (3X)
Ø 5.88 (149.4) MAX.
1.04(26.42) 90°
(2X)
20°±2°
3.74(95.0)
45°
.45±.06(11.43±1.52)
SEE DETAIL “B” POST HEADERASSEMBLY
CUSTOMER WIRING HARNESS WITH AMP CONNECTOR
INCH(MM)
33°
(1) Ø .168±.003 HOLE THRU (4.27±.07)LOCATED AS SHOWN ON Ø 6.40 BOLT CIRCLE. (162.56)
USE THIS HOLE FOR GROUNDING OR EARTHING. REFER TO APPROPRIATE LISTING OR REGULATORY AGENCY FOR PROPER METHOD OF GROUNDING OR EARTHING.
SMØ.034/(.86) A
2.47±.03(62.74±.76)
.875±.062(22.23±1.57)
3.38±.08(85.85±2.03)
.015 / (.38)
“L”
.120 MAX. BOW OUT(3.05)
AIREXHAUST
AIRINTAKE
(3X) Ø .168±.003 HOLE THRU (4.27±.07)LOCATED AS SHOWN ON
Ø 6.50 BOLT CIRCLE.
(165.1)
Ø .034/(.86) A SM
“D2”
“D1”
#1
1 2 3 4 5
#5
LOW (NEGATIVE)
HIGH (POSITIVE)
NOT USED, KEYINGPLUG IN HOLE
+DC INPUT VOLTAGE: 32-64V ± 10%
– DC INPUT VOLTAGE: 32-64V ± 10%
ISOLATED SPEEDCONTROL0-10 VDC
INPUT REQUIRED{
DETAIL “B”POSTER HEADER ASSEMBLY
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
LOW
-VOL
TAGE
BLDC
BLO
WER
S
41
5.7” (145mm) BLDC Thru Flow Blower72 VDC Input, High Flow System
TYPICAL PERFORMANCE
42
5.7” (145mm) BLDC Thru Flow Blower250 Watt, 120 Volt Standard Flow
-A-
ACCESS FORMECHANICALLYADJUSTED SPEEDCONTROL
SENSITIVITY CONTROL
POST HEADER ASSEMBLY
33°
ACCESS TOPOST HEADER
EXHAUSTAIR
EXHAUSTAIR
-B-
AIRINTAKE
"L"
"l"
ISOLATED SPEEDCONTROL1-10V DC
INPUT REQUIRED
POST HEADER ASSEMBLY
AC INPUT(VOLTAGE 120±10%)
AC INPUT(VOLTAGE 120±10%)
NO PINNOT USED
NOT USED
NOT USEDNOT USED
NO PIN
HIGH
LOW{
45°
(2X)90°
"D"2
"D"1
POST HEADERSEE DETAIL OR
"M"DETAIL
CL
CL
DETAIL "E"
"E" "M"INCH(MM)
4.00(101.6)
Ø .034/(0.86) A
.229±.006 .37(5.82±.15) 9.4
Ø 5.88 MAX. (149.4)
32°28°
1.15(29.21)
68°64°
Ø .48 (12.19)+3° MAX.DFT./SIDE (3X)
SM
SM
Ø.034/(.86) A
Ø
(1) Ø HOLE, .168±.003(4.27±.07)
1.43(36.32)
.010/(.25)
.88±.13(22.35±3.3)
3.74(95.0)
6.400(162.56)
THRU, LOCATED AS SHOWNON A BOLT CIRCLE.
USE THIS HOLE FOR GROUNDING OR EARTHING. REFER TO APPROPRIATE LISTING OR REGULATORY AGENCY FOR PROPER METHOD OF GROUNDING OR EARTHING.
.05 MAX. BOW(1.3)
6.500(165.1)
Ø
(3) Ø HOLES THRU,
Ø.034/(0.86) B
.168±.003(.4.27±.07)
LOCATED AS SHOWN ON A BOLT CIRCLE.
SM
(3) Ø HOLES MIN.
DEEP EQUALLY SPACED AS SHOWN ON A Ø BOLT CIRCLE.
Blower Data Unit of MeasurePart Number
Standard Flow116626 M / 116629 E* 116627 M / 116630 E*
Stages — 1 2Vacuum, Maximum (Sealed Vacuum)
in. H2O 28.4 50.0mBar 70.7 124.3
Pressure, Maximum (Sealed Pressure)
in. H2O 29.3 51.5mBar 72.9 128.2
Flow Rate, Maximum (Open Flow)
CFM 64.5 65.4m3/hr 109.6 111.1
Inlet/Outlet Diameter(Dimension “D” above)
inches 1.25 1.25mm 31.75 31.75
Length (Dimension “I” above)
inches 0.74 1.65mm 18.80 41.91
Length (Dimension “L” above)
inches 3.21 4.12mm 81.53 104.65
NOTES: • Nominal Input Voltage: 120 Volts AC RMS ±10%, 50/60Hz.• Input Current: 5 amps AC RMS maximum.• Temperature: Working Air: 0°C to 50°C; Ambient Air: 0°C to 50°C; Storage Air: -40°C to 85°C.• Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage maximum.• Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (user supplied), 0 to 10 Volts DC nominal, 10mA maximum, 3 to 15 volts DC
maximum. Access to sensitivity adjustment for 0 to 10 VDC speed control. (Ref. pin connection). M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specifi c speed. Access to speed adjustment.
• Maximum Approximate Weight: 6 lbs.• Regulatory Agency Certifi cation: Underwriters Laboratories, Inc. is qualifi ed per UL507 under File E-94403. Canadian Standards Association is qualifi ed per
C22.2#113 under File LR 43448.• Miscellaneous: Intake and exhaust tubes, all cooling ducts, and vents must not be obstructed. Intake and exhaust must be free of grease, oil, or foreign par-
ticles. Amp housing #350809-1 (to be supplied by customer), mates with post header assembly.• Mating harness available upon request. Refer to page 136 for specifi c part numbers.• Optional IntelliGen™ controller available for customized performance.
* These part numbers are available through AMETEK Technical & Industrial Products’ distributors.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
HIGH
-VOL
TAGE
BL
DC B
LOW
ERS
43
5.7” (145mm) BLDC Thru Flow Blower250 Watt, 120 Volt Standard Flow
TYPICAL PERFORMANCE
44
5.7” (145mm) BLDC Thru Flow Blower250 Watt, 120 Volt High Flow
-A-
ACCESS FORMECHANICALLYADJUSTED SPEEDCONTROL
SENSITIVITY CONTROL
POST HEADER ASSEMBLY
33°
ACCESS TOPOST HEADER
EXHAUSTAIR
EXHAUSTAIR
-B-
AIRINTAKE
"L"
"l"
ISOLATED SPEEDCONTROL1-10V DC
INPUT REQUIRED
POST HEADER ASSEMBLY
AC INPUT(VOLTAGE 120±10%)
AC INPUT(VOLTAGE 120±10%)
NO PINNOT USED
NOT USED
NOT USEDNOT USED
NO PIN
HIGH
LOW{
45°
(2X)90°
"D"2
"D"1
POST HEADERSEE DETAIL OR
"M"DETAIL
CL
CL
INCH(MM)
DETAIL "E"
"E" "M"
4.00(101.6)
Ø .034/(0.86) A
.229±.006 .37(5.82±.15) 9.4
Ø 5.88 MAX. (149.4)
32°28°
1.15(29.21)
68°64°
Ø .48 (12.19)+3° MAX.DFT./SIDE (3X)
SM
SM
Ø.034/(.86) A
Ø
(1) Ø HOLE, .168±.003(4.27±.07)
1.43(36.32)
.010/(.25)
.88±.13(22.35±3.3)
3.74(95.0)
6.400(162.56)
THRU, LOCATED AS SHOWNON A BOLT CIRCLE.
USE THIS HOLE FOR GROUNDING OR EARTHING. REFER TO APPROPRIATE LISTING OR REGULATORY AGENCY FOR PROPER METHOD OF GROUNDING OR EARTHING.
.05 MAX. BOW(1.3)
6.500(165.1)
Ø
(3) Ø HOLES THRU, .168±.003(.4.27±.07)
LOCATED AS SHOWN ON A BOLT CIRCLE.
SMØ.034/(0.86) B
(3) Ø HOLES MIN.
DEEP EQUALLY SPACED AS SHOWN ON A Ø BOLT CIRCLE.
NOTES:• Nominal Input Voltage: 120 Volts AC RMS ±10%, 50/60Hz.• Input Current: 5 amps AC RMS maximum.• Temperature: Working Air: 0°C to 50°C; Ambient Air: 0°C to 50°C; Storage Air: -40°C to 85°C.• Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage maximum.• Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (user supplied), 0 to 10 Volts DC nominal, 10mA maximum, 3 to 15 volts DC
maximum. Access to sensitivity adjustment for 0 to 10 VDC speed control. (Ref. pin connection). M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specifi c speed. Access to speed adjustment.
• Maximum Approximate Weight: 6 lbs.• Regulatory Agency Certifi cation: Underwriters Laboratories, Inc. is qualifi ed per UL507 under File E-94403. Canadian Standards Association is qualifi ed per
C22.2#113 under File LR 43448.• Miscellaneous: Intake and exhaust tubes, all cooling ducts, and vents must not be obstructed. Intake and exhaust must be free of grease, oil, or foreign par-
ticles. Amp housing #350809-1 (to be supplied by customer), mates with post header assembly.• Mating harness available upon request. Refer to page 136 for specifi c part numbers.• Optional IntelliGen™ controller available for customized performance.
Blower Data Unit of MeasurePart Number
High Flow116644 M / 116647 E 116645 M / 116648 E
Stages — 1 2Vacuum, Maximum (Sealed Vacuum)
in. H2O 26.5 46.7
mBar 65.9 116.1Pressure, Maximum (Sealed Pressure)
in. H2O 27.3 48.1mBar 67.9 119.7
Flow Rate, Maximum (Open Flow)
CFM 130.5 98.2m3/hr 221.7 166.9
Inlet/Outlet Diameter(Dimension “D” above)
inches 1.75 1.75mm 44.45 44.45
Length (Dimension “I” above)
inches 0.76 1.88mm 19.3 47.75
Length (Dimension “L” above)
inches 3.28 4.33mm 83.31 109.98
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
HIGH
-VOL
TAGE
BL
DC B
LOW
ERS
45
5.7” (145mm) BLDC Thru Flow Blower250 Watt, 120 Volt High Flow
TYPICAL PERFORMANCE
46
5.7” (145mm) BLDC Thru Flow “Heavy Duty” Blower250 Watt, 120 Volt Standard Flow
Blower Data Unit of MeasurePart Number
Standard Flow156630
Stages — 2Vacuum, Maximum (Sealed Vacuum)
in. H2O 52.1mBar 129.6
Pressure, Maximum (Sealed Pressure)
in. H2O 53.7mBar 133.6
Flow Rate, Maximum (Open Flow)
CFM 65.1m3/hr 110.6
Inlet/Outlet Diameter inches 1.27mm 31.75
Length (From Mounting Ear To Inlet)
inches 2.15mm 54.61
Length (Total Axial)
inches 4.18mm 106.17
NOTES: • The Heavy Duty (HD) Windjammer design has an alternate bearing confi guration that improves the blower’s ability to retain the factory balance specifi cations
when subjected to external shock and impact.• Nominal input Voltage: 120 Volts AC RMS ±10%, 50/60Hz.• Input Current: 5 amps AC RMS maximum.• Temperature: Working Air: 0°C to 50°C; Ambient Air: 0°C to 50°C; Storage Air: -40°C to 85°C.• Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage maximum.• Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (user supplied), 0 to 10 Volts DC nominal, 10mA maximum, 3 to 15 volts DC
maximum. Access to sensitivity adjustment for 0 to 10 VDC speed control. (Ref. pin connection).• Maximum Approximate Weight: 6 lbs.• Regulatory Agency Certifi cation: Underwriters Laboratories, Inc. is qualifi ed per UL507 under File E-94403. Canadian Standards Association is qualifi ed per
C22.2#113 under File LR 43448.• Miscellaneous: Intake and exhaust tubes, all cooling ducts, and vents must not be obstructed. Intake and exhaust must be free of grease, oil, or foreign par-
ticles. Amp housing #350809-1 (to be supplied by customer), mates with post header assembly.• Mating harness available upon request. Refer to page 136 for specifi c part numbers.• Utilizes AMETEK’s IntelliGen™ control electronics.
(1) #10-32 UNF-2B ROLL FORM THD’S. THRU, LOCATED AS SHOWN ON A 6.40
Ø (162.56)BOLT CIRCLE.
USE THIS HOLE FOR GROUNDING OR EARTHING. REFER TO APPROPRIATE LISTING OR REGULATORY AGENCY FOR PROPER METHOD OF GROUNDING OR EARTHING.
(4) #10-32 UNF-2B ROLL FORM THD’S. THRU, SPACED AS SHOWN ON A 6.50
Ø (165.10)BOLT CIRCLE.
WHITE WIRE
BLACK WIRE
GREEN/YELLOW WIRE
RED WIRE
BLUE WIRE
54321
AC INPUT VOLTAGE
GROUND ( )
HIGH (+) ISOLATED SPEEDLOW ( – ) } CONTROL INPUT
CONNECTION DIAGRAM
6.0±.50(152.40±12.7)
54°±2°
54°±2°
2.03±.05(51.56±1.27)
2.15±.05(54.61±1.27)
2.37(60.20)
45°
33°
90°(4X)
3.74(95.00)
1.04(26.42)
.05(1.3) MAX. BOW
5.88Ø(149.4) MAX.
1.27Ø (32.26)
1.27Ø (31.75)+1.5° MAX.DRAFT/SIDE
A
AIREXHAUST
AIRINTAKE
SENSITIVITY CONTROL
ACCESS TO SENSITIVITY ADJUSTMENT FOR 0 TO 10 V
D.C. SPEED CONTROL(UNDER ADHESIVE COVE)
CL
INCH(MM)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
HIGH
-VOL
TAGE
BL
DC B
LOW
ERS
47
5.7” (145mm) BLDC Thru Flow “Heavy Duty” Blower250 Watt, 120 Volt Standard Flow
TYPICAL PERFORMANCE
48
5.7” (145mm) BLDC Bypass Blower250 Watt, 120 Volt Standard Flow
37°±2°
33°
.48(12.19)
1.04(26.42)
AIRINTAKE
-A- “D”2
“D”1
.05(1.3)
MAX BOWTYP. BOTHENDS
.88±.13(22.35±3.3)
3.10±.06(78.74±1.52)
.015/(.38)
“L”
“I”
ACCESS FOR MECHANICALLYADJUSTED SPEED CONTROL
SPEEDCONTROL
SEE DETAIL “E” OR “M”
INCH(MM) AIR
EXHAUST3.74
(95.0)
90°(3X)
45°
6.500(165.1)
Ø
(4) Ø HOLES THRU, .168±.003(4.27±.07)
LOCATED AS SHOWN ON A BOLT CIRCLE.
SMØ.024/(.61) A
ISOLATED SPEEDCONTROL1-10V DC
INPUT REQUIRED
AC INPUT(VOLTAGE 120±10%)
NO PINNOT USED
HIGH
LOW
AC INPUT(VOLTAGE 120±10%)
NO PINNOT USEDNOT USEDNOT USED}
POST HEADER ASSEMBLYDETAIL “E”
POST HEADER ASSEMBLYDETAIL “M”
SMØ.024/(.61) A
Ø
(1) Ø HOLE, .168±.003(4.27±.07)
6.400(162.56)
2.32(58.93)
THRU, LOCATED AS SHOWNON A BOLT CIRCLE.
USE THIS HOLE FOR GROUNDING OR EARTHING. REFER TO APPROPRIATE LISTING OR REGULATORY AGENCY FOR PROPER METHOD OF GROUNDING OR EARTHING.
Ø 1.26 MAX. (32.0)
Ø 5.88 MAX. (149.4)
Blower Data Unit of MeasurePart Number
Standard Flow116634 M* / 116640 E* 116633 M / 116639 E 116632 M* / 116638 E*
Stages — 1 2 3Vacuum, Maximum (Sealed Vacuum)
in. H2O 29.5 40.1 78.4mBar 73.4 99.8 195.0
Pressure, Maximum (Sealed Pressure)
in. H2O 30.4 41.3 80.5mBar 73.3 102.3 200.3
Flow Rate, Maximum (Open Flow)
CFM 75.9 65.6 56.4m3/hr 127.3 111.4 95.9
Inlet/Outlet Diameter(Dimension “D” above)
inches 1.25 1.25 1.25mm 31.75 31.75 31.75
Length (Dimension “I” above)
inches 0.33 1.25 2.14mm 8.38 31.75 54.36
Length (Dimension “L” above)
inches 5.08 6.35 6.89mm 129.03 161.29 175.01
NOTES: • Nominal Input Voltage: 120 Volts AC RMS ±10%, 50/60Hz.• Input Current: 5 amps AC RMS maximum.• Temperature: Working Air: 0°C to 50°C; Ambient Air: 0°C to 50°C; Storage Air: -40°C to 85°C.• Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage maximum.• Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (user supplied), 0 to 10 Volts DC nominal, 10mA maximum, 3 to 15 volts DC
maximum. Access to sensitivity adjustment for 0 to 10 VDC speed control. (Ref. pin connection). M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specifi c speed. Access to speed adjustment.
• Maximum Approximate Weight: 6 lbs.• Regulatory Agency Certifi cation: Underwriters Laboratories, Inc. is qualifi ed per UL507 under File E-94403; Canadian Standards Association is qualifi ed per
C22.2#113 under File LR 43448.• Miscellaneous: Intake and exhaust tubes, all cooling ducts, and vents must not be obstructed. Intake and exhaust are free of grease, oil, or foreign particles.
Amp housing #640250-6 (to be supplied by customer), mates with post header assembly.• Mating harness available upon request. Refer to page 136 for specifi c part numbers.• Optional – Universal AC input version available with IntelliGen™ control (120-240 VAC input).• Optional – Tachometer output card available with IntelliGen™ controller.
* These part numbers are available through AMETEK Technical & Industrial Products’ distributors.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
HIGH
-VOL
TAGE
BL
DC B
LOW
ERS
49
5.7” (145mm) BLDC Bypass Blower250 Watt, 120 Volt Standard Flow
TYPICAL PERFORMANCE
50
5.7” (145mm) BLDC Bypass Blower250 Watt, 120 Volt High Flow
SMØ.024/(.61) A
Ø
(1) Ø HOLE, .168±.003(4.27±.07)
6.400(162.56)
37°±2°
33°
2.32(58.93)
.48(12.19)
1.04(26.42)
.88±.13(22.35±3.3)
AIRINTAKE
-A- “D”2
“D”1
.05(1.3)
MAX BOWTYP. BOTHENDS
3.10±.06(78.74±1.52)
.015/(.38)
“L”
“I”
SPEEDCONTROL
SEE DETAIL “E” OR “M”INCH(MM)
AIREXHAUST
3.74(95.0)
90°(3X)
45°
THRU, LOCATED AS SHOWNON A BOLT CIRCLE.
USE THIS HOLE FOR GROUNDING OR EARTHING. REFER TO APPROPRIATE LISTING OR REGULATORY AGENCY FOR PROPER METHOD OF GROUNDING OR EARTHING.
6.500(165.1)
Ø
(4) Ø HOLES THRU, .168±.003(.4.27±.07)
LOCATED AS SHOWN ON A BOLT CIRCLE.
SMØ.024/.61 A
ISOLATED SPEEDCONTROL1-10V DC
INPUT REQUIRED
AC INPUT(VOLTAGE 120±10%)
NO PINNOT USED
HIGH
LOW
AC INPUT(VOLTAGE 120±10%)
NO PINNOT USEDNOT USEDNOT USED}
POST HEADER ASSEMBLYDETAIL “E”
POST HEADER ASSEMBLYDETAIL “M”
LC
Ø 1.26 MAX. (32.0)
Ø 5.88 MAX. (149.4)
Blower Data Unit of MeasurePart Number
High Flow116637 M* / 116643 E* 116636 M* / 116642 E* 116635 M / 116641 E
Stages — 1 2 3Vacuum, Maximum (Sealed Vacuum)
in. H2O 25.2 49.7 67.2mBar 62.8 123.6 167.3
Pressure, Maximum (Sealed Pressure)
in. H2O 26.0 51.2 69.3mBar 64.5 127.0 171.8
Flow Rate, Maximum (Open Flow)
CFM 130.5 103.9 82.3m3/hr 221.8 176.6 139.9
Inlet/Outlet Diameter(Dimension “D” above)
inches 1.75 1.75 1.75mm 44.45 44.45 44.45
Length (Dimension “I” above)
inches 0.47 1.53 2.53mm 11.94 38.86 64.26
Length (Dimension “L” above)
inches 5.22 6.27 7.28mm 132.59 159.26 184.91
NOTES: • Nominal Input Voltage: 120 Volts AC RMS ±10%, 50/60Hz.• Input Current: 5 amps AC RMS maximum.• Temperature: Working Air: 0°C to 50°C; Ambient Air: 0°C to 50°C; Storage Air: -40°C to 85°C.• Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage maximum.• Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (user supplied), 0 to 10 Volts DC nominal, 10mA maximum, 3 to 15 volts DC
maximum. Access to sensitivity adjustment for 0 to 10 VDC speed control. (Ref. pin connection). M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specifi c speed. Access to speed adjustment.
• Maximum Approximate Weight: 6 lbs.• Regulatory Agency Certifi cation: Underwriters Laboratories, Inc. is qualifi ed per UL507 under File E-94403; Canadian Standards Association is qualifi ed per
C22.2#113 under File LR 43448.• Miscellaneous: Intake and exhaust tubes, all cooling ducts, and vents must not be obstructed. Intake and exhaust are free of grease, oil, or foreign particles.
Amp housing #640250-6 (to be supplied by customer), mates with post header assembly.• Mating harness available upon request. Refer to page 136 for specifi c part numbers.• Optional – Universal AC input version available with IntelliGen™ control (120-240 VAC input).• Optional – Tachometer output card available with IntelliGen™ controller.
* These part numbers are available through AMETEK Technical & Industrial Products’ distributors.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
HIGH
-VOL
TAGE
BL
DC B
LOW
ERS
51
5.7” (145mm) BLDC Bypass Blower250 Watt, 120 Volt High Flow
TYPICAL PERFORMANCE
52
5.7” (145mm) BLDC Thru Flow Blower400 Watt, 240 Volt Standard Flow
45°
90°(2X)
33°
AIRINTAKE
-A-
“L”
“I”
SPEEDCONTROL
ACCESS FORMECHANICALLYADJUSTED SPEEDCONTROL
AIREXHAUST
POST HEADERSEE DETAIL “E” OR “M”
INCH(MM)
ISOLATED SPEEDCONTROL1-10V DC
INPUT REQUIRED
AC INPUT VOLTAGE(VOLTAGE 240±10%)
NO PIN
HIGH (+)
LOW (-)
AC INPUT(VOLTAGE 240±10%)
NOT USED
NOT USED
GROUND ( )
}
POST HEADER ASSEMBLYDETAIL “E”
POST HEADER ASSEMBLYDETAIL “M”
LC
Ø 1.25
(31.75)
Ø 1.25
(31.75)
1.04(26.42)
3.74(95.0)
4.00(101.6)Ø
(3) Ø HOLES MIN. DEEP EQUALLY SPACED AS SHOWNON A BOLT CIRCLE.
.229±.006 .37(5.82±.15) (9.4)
SMØ.034/(0.86) A
Ø 5.88
MAX. (149.4)
(3X) Ø 0.48
(12.19) +3° MAX. DFT./SIDE
.05 MAX. BOW(1.3)
.75±.13(19.1±3.3)
1.14±.05(28.96±1.27)
1.47(37.34)
45°41°
39°±2°
.015/(.38)
4.50±1.0(114.3±25.4)
6.400(162.56)Ø
(1) Ø HOLES THRU. LOCATED AS SHOWN ON A BOLT CIRCLE.
USE THIS HOLE FOR GROUNDING OR EARTHING. REFER TO APPROPRIATE LISTING OR REGULATORY AGENCY FOR PROPER METHOD OF GROUNDING OF EARTHING.
.168±.003(4.27±.07)
SMØ.034/(0.86) A
6.50(165.1)Ø
(3) Ø HOLES THRU. LOCATED AS SHOWN ON A BOLT CIRCLE.
.168±.003(4.27±.07)
SMØ.034/(0.86) A
Blower Data Unit of MeasurePart Number
Standard Flow117629 E* 117630 E*
Stages — 1 2
Vacuum, Maximum (Sealed Vacuum)
in. H2O 28 47
mBar 69 117
Pressure, Maximum (Sealed Pressure)
in. H2O 31 50
mBar 77 124
Flow Rate, Maximum (Open Flow)
CFM 67 65
m3/hr 114 110
Length (Dimension “I” above)
inches .69 1.60
mm 17.53 40.64
Length (Dimension “L” above)
inches 3.21 4.12
mm 81.53 104.65
NOTES: • Nominal input Voltage: 240 Volts AC RMS ±10%, 50/60Hz.• Input Current: 5 amps AC RMS maximum.• Temperature: Working Air: 0°C to 50°C, Ambient Air: 0°C to 50°C, Storage Air: -40°C to 85°C.• Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.• Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (user supplied), 0 to 10 Volts DC nominal, 10mA maximum, 3 to 15 volts DC
maximum. Access to sensitivity adjustment for 0 to 10 VDC speed control. (Ref. pin connection). M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specifi c speed. Access to speed adjustment.
• Optional: IntelliGen™ controller available for customized performance.• Maximum Approximate Weight: 6 lbs.
* These part numbers are available through AMETEK Technical & Industrial Products’ distributors.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
HIGH
-VOL
TAGE
BL
DC B
LOW
ERS
53
5.7” (145mm) BLDC Thru Flow Blower400 Watt, 240 Volt Standard Flow
TYPICAL PERFORMANCE
54
5.7” (145mm) BLDC Bypass Blower400 Watt, 240 Volt Standard Flow
(3X)90°
12345
HIGH
LOW
AC INPUT(VOLTAGE 240±10%)
GROUND
AIRINTAKE
POST HEADER ASSEMBLY
DETAIL “E” POST HEADER ASSEMBLY
DETAIL “M”
-A-
ISOLATED SPEEDCONTROL0-10. D.C.
INPUT REQUIRED}
ACCESS FOR MECHANICALLYADJUSTED SPEED CONTROL
CLSENSITIVITYCONTROL
NCR
I
E SA
E
AIREXHAUST
“L”
“l”
GROUND
AC INPUT(VOLTAGE 240±10%)
NOT USED
NOT USED
5 4 3 2 1
"D"2
"D"1
SMØ.024/(.61) A
Ø
(1) Ø HOLE THRU,.168±.003(4.27±.07)
6.400(162.56)
37°±2°
43°±2°
33°
2.38(60.45)
.59(15.0)
1.04(26.42)
.88±.13(22.35±3.3)
.05(1.3)
MAX BOWTYP. BOTHENDS
3.22±.06(81.79±1.52)
.015/(.38)
SEE DETAIL “E” OR “M”INCH(MM)
3.74(95.0)
47°43°
LOCATED AS SHOWN ON BOLT CIRCLE.
USE THIS HOLE FOR GROUNDING OR EARTHING. REFER TO APPROPRIATE LISTING OR REGULATORY AGENCY FOR PROPER METHOD OF GROUNDING OR EARTHING.
6.500(165.1)
Ø
(4) Ø HOLES THRU, .168±.003(.4.27±.07)
LOCATED AS SHOWN ON A BOLT CIRCLE.
MØ.024/.61 A
Ø 1.26 MAX. (32.0)
Ø 5.88 MAX. (149.4)
Blower Data Unit of MeasurePart Number
Standard Flow117634 M* / 117640 E* 117633 M / 117639 E 117632 M* / 117638 E*
Stages — 1 2 3
Vacuum, Maximum (Sealed Vacuum)
in. H2O 28 45 60
mBar 69 112 149
Pressure, Maximum (Sealed Pressure)
in. H2O 30 51 72
mBar 74 126 174
Flow Rate, Maximum (Open Flow)
CFM 70 67 65
m3/hr 119 114 110
Inlet/Outlet Diameter(Dimension “D” above)
inches 1.25 1.25 1.25
mm 31.75 31.75 31.75
Length (Dimension “I” above)
inches 2.53 1.25 2.14
mm 64.26 31.75 54.36
Length (Dimension “L” above)
inches 5.08 5.99 6.89
mm 129.03 152.15 175.01
NOTES:• Nominal Input Voltage: 240 Volts AC RMS ±10%, 50/60Hz.• Input Current: 5 amps AC RMS maximum.• Temperature: Working Air: 0°C to 50°C, Ambient Air: 0°C to 50°C, Storage Air: -40°C to 85°C.• Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.• Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (user supplied), 0 to 10 Volts DC nominal, 10mA maximum, 3 to 15 volts DC
maximum. Access to sensitivity adjustment for 0 to 10 VDC speed control. (Ref. pin connection). M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specifi c speed. Access to speed adjustment.
• Optional: IntelliGen™ controller available for customized performance.
* These part numbers are available through AMETEK Technical & Industrial Products’ distributors.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
HIGH
-VOL
TAGE
BL
DC B
LOW
ERS
55
5.7” (145mm) BLDC Bypass Blower400 Watt, 240 Volt Standard Flow
TYPICAL PERFORMANCE
56
5.7” (145mm) BLDC Bypass Blower400 Watt, 240 Volt High Flow
(3X)90°
43°47°
12345 12345
33°
SEE DETAIL “E” OR “M”
43°±2°
37°±2°
HIGH
LOW
AC INPUT(VOLTAGE 240±10%)
GROUND
AIRINTAKE
POST HEADER ASSEMBLY
DETAIL “E” POST HEADER ASSEMBLY
DETAIL “M”
-A-
MAX. BOWTYP. BOTHENDS
ISOLATED SPEEDCONTROL0-10. D.C.
INPUT REQUIRED}
ACCESS FOR MECHANICALLYADJUSTED SPEED CONTROL
CLSENSITIVITYCONTROL
AIREXHAUST
“L”
“l”
GROUND
AC INPUT(VOLTAGE 240±10%)
NOT USED
NOT USED
"D"2
"D"1
M
(4) Ø HOLES THRU,
EQUALLY SPACED AS SHOWN ON A BOLT CIRCLE.
Ø
INCH(MM)
2.38(60.45)
1.04(26.42)
3.74(95.0)0.59
(15.0)
3.22±.06(81.79±1.52)
.88±.13(22.35±3.3)
.05(1.3).015/(0.38)
Ø 1.26 MAX. (32.0)
Ø 5.88 MAX. (149.4)
Ø.024/(.61) A
4.27±.07(.168±.003)
6.500(165.1)
SMØ.024/(.61) A
Ø
(1) Ø HOLE, .168±.003(4.27±.07)
6.400(162.56)
THRU, LOCATED AS SHOWNON A BOLT CIRCLE.
USE THIS HOLE FOR GROUNDING OR EARTHING. REFER TO APPROPRIATE LISTING OR REGULATORY AGENCY FOR PROPER METHOD OF GROUNDING OR EARTHING.
Blower Data Unit of MeasurePart Number
High Flow117637 M* / 117643 E* 117636 M* / 117642 E* 117635 M* / 117641 E*
Stages — 1 2 3
Vacuum, Maximum (Sealed Vacuum)
in. H2O 23 39 53
mBar 57 97 131
Pressure, Maximum (Sealed Pressure)
in. H2O 25 45 61
mBar 62 112 151
Flow Rate, Maximum (Open Flow)
CFM 125 102 90
m3/hr 212 173 153
Inlet/Outlet Diameter(Dimension “D” above)
inches 1.75 1.75 1.75
mm 44.45 44.45 44.45
Length (Dimension “I” above)
inches .47 1.53 2.53
mm 11.94 38.86 64.26
Length (Dimension “L” above)
inches 5.22 6.27 7.28
mm 132.59 159.26 184.91
NOTES:• Nominal Input Voltage: 240 Volts AC RMS ±10%, 50/60Hz.• Input Current: 5 amps AC RMS maximum.• Temperature: Working Air: 0°C to 50°C, Ambient Air: 0°C to 50°C, Storage Air: -40°C to 85°C.• Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.• Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (user supplied), 0 to 10 Volts DC nominal, 10mA maximum, 3 to 15 volts DC
maximum. Access to sensitivity adjustment for 0 to 10 VDC speed control. (Ref. pin connection). M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specifi c speed. Access to speed adjustment.
• Optional: IntelliGen™ controller available for customized performance.
* These part numbers are available through AMETEK Technical & Industrial Products’ distributors.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
HIGH
-VOL
TAGE
BL
DC B
LOW
ERS
57
5.7” (145mm) BLDC Bypass Blower400 Watt, 240 Volt High Flow
TYPICAL PERFORMANCE
58
5.7” (145mm) BLDC Bypass Blower800 Watt, 120 Volt Standard Flow – IntelliGen™
-B-
ACCESS FOR MECHANICALLYADJUSTED SPEED CONTROL
26°±2° 33°
-B-
-B-
AIREXHAUSTINCH
(MM)
MAX. BOWTYP. BOTHENDS
90°(2X)
45°
INTAKEAIR
-A-
AC INPUT VOLTAGE3
5
4
1
2
NOT USEDNOT USED
“I”
“L”
AC INPUT VOLTAGE
ISOLATED SPEEDCONTROL INPUT
3
5
4
LOW (-)
GROUND ( )
HIGH (+)
1
2
}GROUND ( )
49°±2°
SPEEDCONTROL
LC
POST HEADER ASSEMBLY
VIEW “B”
SEE DETAIL
“E” OR “M”
SEE VIEW “B”
DETAIL “E”
"D"2
"D"1
POST HEADER ASSEMBLYDETAIL “M”
SMØ.024/(.61) A
Ø
(1) Ø HOLE, .168±.003(4.27±.07)
6.400(162.56)
THRU, LOCATED AS SHOWNON A BOLT CIRCLE.
USE THIS HOLE FOR GROUNDING OR EARTHING. REFER TO APPROPRIATE LISTING OR REGULATORY AGENCY FOR PROPER METHOD OF GROUNDING OR EARTHING.
2.40(60.97)
Ø 2.60 MAX. (66.04)
2.79±.08(70.87±2.03)
3.29±.06(83.57±1.52)
1.38(35.05)REF.
1.04(26.42)
3.74(95.0)
.88±.13(22.35±3.3)
.05(1.3)
.015/(.38)
Ø 5.88 MAX. (149.4)
6.500(165.1)
Ø
(3) Ø HOLES THRU, .168±.003(.4.27±.07)
LOCATED AS SHOWN ON A BOLT CIRCLE.
SMØ.024/.61 A
Blower Data Unit of MeasurePart Number
Standard Flow117418 M* / 117417 E*
Stages — 3
Vacuum, Maximum (Sealed Vacuum)
in. H2O 102
mBar 254
Pressure, Maximum (Sealed Pressure)
in. H2O 122
mBar 303
Flow Rate, Maximum (Open Flow)
CFM 76
m3/hr 129
Inlet/Outlet DiameterDimension “D” above)
inches 1.25
mm 31.75
Length (Dimension “I” above)
inches 2.12
mm 53.85
Length (Dimension “L” above)
inches 6.87
mm 174.50
* These part numbers are available through AMETEK Technical & Industrial Products’ distributors.
NOTES:OPERATING PARAMETERS:• Input Voltage Range: 120 Volt AC Models: 92 to 132 VAC RMS, 50/60 Hz, single phase, maximum running current 10 Amps RMS.
Note: Although this unit contains a lockout feature that detects low voltage conditions, the electronics should not be operated continuously below the input voltage range listed above.
• Isolated Speed Control: Analog Input Voltage Range: 2.2 to +10 VDC nominal, (+12 VDC maximum). Digital Pulse Input: 400 Hz to 20 KHz, 0 to +10 Volt pulse nominal, minimum duty cycle 10%, 0 to +12 Volt maximum.Note: Setting of potentiometer can affect control voltage range and maximum speed can be reached before reaching 10 VDC.
• Speed Control Input Current: Less than 20 mA at 10 Volts input with multi turn internal potentiometer set to minimum (fully counter-clockwise).• Speed Control Drift with Temperature:
Analog Mode: Typ. +/-4% from nominal speed at +23°C.Digital or Direct Mode: Typ. +/-4% from nominal speed at +23°C.
• Operating Temperature: 0°C to 50°C.• Storage Temperature: -40°C to 85°C.
Note: Internal electronic controller is thermally protected.• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage max.• Approximate Weight: 6 lbs.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
HIGH
-VOL
TAGE
BL
DC B
LOW
ERS
59
5.7” (145mm) BLDC Bypass Blower800 Watt, 120 Volt Standard Flow – IntelliGen™
TYPICAL PERFORMANCE
INSTALLATION:• The blower must be secured using mounting tabs, prior to applying power. This is a high speed device with rapid acceleration.• Connections:
All of the Windjammer IntelliGen™ series blowers have a standard 5 pin connector.A mating connector with leads is supplied with single pack units only.Negative pressure applications will exhibit reduced performance.The electronic cooling intake and exhaust must remain unobstructed.Exhaust air must be prohibited from being recycled to inlet air.If blower is to be cycled frequently, the DC speed command should be used.For use in industrial applications, use AMETEK Technical & Industrial Products cooling air fi lters.Note: Utilize AMETEK external EMC fi lter accessory to meet EN61000-4-6 requirement.
• Option Circuit Connections: Please consult with AMETEK for connection details for all optional and custom circuitry.• Utilizes AMETEK’s IntelliGen™ control electronics.
60
5.7” (145mm) BLDC Bypass Blower800 Watt, 120 Volt High Flow – IntelliGen™
-B-
ACCESS FOR MECHANICALLYADJUSTED SPEED CONTROL
26°±2° 33°
-B-
-B-
AIREXHAUSTINCH
(MM)
MAX. BOWTYP. BOTHENDS
90°(2X)
45°
INTAKEAIR
-A-
AC INPUT VOLTAGE3
5
4
1
2
NOT USEDNOT USED
“I”
“L”
AC INPUT VOLTAGE
ISOLATED SPEEDCONTROL INPUT
3
5
4
LOW (-)
GROUND ( )
HIGH (+)
1
2
}GROUND ( )
49°±2°
SPEEDCONTROL
LC
POST HEADER ASSEMBLY
VIEW “B”
SEE DETAIL
“E” OR “M”
SEE VIEW “B”
DETAIL “E”
"D"2
"D"1
SM
(3) Ø HOLES THRU,
LOCATED AS SHOWN ON
BOLT CIRCLE.Ø
USE THIS HOLE FORGROUNDING OR EARTHING.REFER TO APPROPRIATELISTING OR REGULATORYAGENCY FOR PROPER METHOD OF GROUNDING OR EARTHING.
BOLT CIRCLE.
LOCATED AS SHOWN ON
HOLE THRU,(1) Ø
Ø.024/(.61) A M S
Ø
POST HEADER ASSEMBLYDETAIL “M”
2.40(60.97) .168±.003
(4.27±.07)
6.400(162.56)
1.04(26.42)
.88±.13(22.35±3.3)
3.74(95.0)
.05(1.3)
1.38(35.05)REF.
3.29±.06(83.57±1.52)
2.79±.08(70.87±2.03)
.015/(.38)
Ø 5.88 MAX. (149.4)
Ø.024/(.61) A
.168±.003(4.27±.07)
6.500(165.1)
Blower Data Unit of MeasurePart Number
High Flow Ultra Flow119102 M* / 119101 E* 119104 M* / 119103 E* 119105 E*
Stages — 1 2 1
Vacuum, Maximum (Sealed Vacuum)
in. H2O 37 67 26
mBar 92 167 64
Pressure, Maximum (Sealed Pressure)
in. H2O 41 78 29
mBar 102 194 72
Flow Rate, Maximum (Open Flow)
CFM 168 131 226
m3/hr 285 222 384
Inlet/Outlet DiameterDimension “D” above)
inches 1.75 1.75 2.75/2.50
mm 44.45 44.45 69.85/63.50
Length (Dimension “I” above)
inches .47 1.53 .71
mm 11.94 38.86 18.03
Length (Dimension “L” above)
inches 5.30 6.35 5.46
mm 134.62 161.29 138.68
* These part numbers are available through AMETEK Technical & Industrial Products’ distributors.
NOTES:OPERATING PARAMETERS:• Input Voltage Range: 120 Volt AC Models: 92 to 132 VAC RMS, 50/60 Hz, single phase, maximum running current 10 Amps RMS.
Note: Although this unit contains a lockout feature that detects low voltage conditions, the electronics should not be operated continuously below the input voltage range listed above.
• Isolated Speed Control: Analog Input Voltage Range: 2.2 to +10 VDC nominal, (+12 VDC maximum). Digital Pulse Input: 400 Hz to 20 KHz, 0 to +10 Volt pulse nominal, minimum duty cycle 10%, 0 to +12 Volt maximum.Note: Setting of potentiometer can affect control voltage range and maximum speed can be reached before reaching 10 VDC.
• Speed Control Input Current: Less than 20 mA at 10 Volts input with multi turn internal potentiometer set to minimum (fully counter-clockwise).• Speed Control Drift with Temperature:
Analog Mode: Typ. +/-4% from nominal speed at +23°C.Digital or Direct Mode: Typ. +/-4% from nominal speed at +23°C.
• Operating Temperature: 0°C to 50°C.• Storage Temperature: -40°C to 85°C.
Note: Internal electronic controller is thermally protected.• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage max.• Approximate Weight: 6 lbs.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
HIGH
-VOL
TAGE
BL
DC B
LOW
ERS
61
5.7” (145mm) BLDC Bypass Blower800 Watt, 120 Volt High Flow – IntelliGen™
TYPICAL PERFORMANCE
INSTALLATION:• The blower must be secured using mounting tabs, prior to applying power. This is a high speed device with rapid acceleration.• Connections:
All of the Windjammer IntelliGen™ series blowers have a standard 5 pin connector.A mating connector with leads is supplied with single pack units only.Negative pressure applications will exhibit reduced performance.The electronic cooling intake and exhaust must remain unobstructed.Exhaust air must be prohibited from being recycled to inlet air.If blower is to be cycled frequently, the DC speed command should be used.For use in industrial applications, use AMETEK Technical & Industrial Products cooling air fi lters.Note: Utilize AMETEK external EMC fi lter accessory to meet EN61000-4-6 requirement.
• Option Circuit Connections: Please consult with AMETEK for connection details for all optional and custom circuitry.• Utilizes AMETEK’s IntelliGen™ control electronics.
62
5.7” (145mm) DC Bypass Blower1200 Watt, 240 Volt Standard Flow – IntelliGen™
SEE VIEW “B”
-B-
ACCESS FOR MECHANICALLYADJUSTED SPEED CONTROL
26°±2°54°30'±2° 33°
SPEEDCONTROL
LC
-B-
-B-
AIREXHAUST
MAX. BOW TYP. BOTH ENDS
90°(2X)
45°
INTAKEAIR
-A-
“I”
“L”
INCH(MM)
2
4
5
3
1
AC INPUT VOLTAGE
GROUND ( )
NOT USEDNOT USED
AC INPUT VOLTAGE
LOW (-)
GROUND ( )
HIGH (+)
2
5
4
3
1
ISOLATED SPEEDCONTROL INPUT}
"D"2
"D"1
POST HEADER ASSEMBLYDETAIL “M”
SEE DETAIL “E” OR “M”
POST HEADER ASSEMBLYDETAIL “E”
VIEW “B”
M S
LOCATED AS SHOWN ON
BOLT CIRCLE. Ø
(1) Ø HOLE THRU,
USE THIS HOLE FORGROUNDING OR EARTHING.REFER TO APPROPRIATELISTING OR REGULATORYAGENCY FOR PROPER METHOD OF GROUNDING OR EARTHING. 6.500
(165.1)Ø
(3) Ø HOLES THRU, .168±.003(.4.27±.07)
LOCATED AS SHOWN ON A BOLT CIRCLE.
SMØ.024/.61 A
.168±.003(4.27±.07)
1.04(26.42)
.05(1.3)
.88±.13(22.35±3.3)
3.29±.06(83.57±1.52)
2.79±.08(70.87±2.03)
1.38(35.05)REF.
3.74(95.0)
6.400(162.56)
Ø.024/(.61) A
Ø.015/(.38)
2.40(60.97)
Ø 2.60 MAX. (66.04) Ø 5.88 MAX. (149.4)
NOTES:OPERATING PARAMETERS:• Input Voltage Range: 240 Volt AC Models: 208 to 264 VAC RMS, 50/60 Hz, single phase, maximum running current 10 Amps RMS.
Note: Although this unit contains a lockout feature that detects low voltage conditions, the electronics should not be operated continuously below the input voltage range listed above.
• Isolated Speed Control: Analog Input Voltage Range: 2.2 to +10 VDC nominal, (+12 VDC maximum). Digital Pulse Input: 400 Hz to 20 KHz, 0 to +10 Volt pulse nominal, minimum duty cycle 10%, 0 to +12 Volt maximum.Note: Setting of potentiometer can affect control voltage range and maximum speed can be reached before reaching 10 VDC.
• Speed Control Input Current: Less than 20 mA at 10 Volts input with multi turn internal potentiometer set to minimum (fully counter-clockwise).• Speed Control Drift with Temperature:
Analog Mode: Typ. +/-4% from nominal speed at +23°C.Digital or Direct Mode: Typ. +/-4% from nominal speed at +23°C.
• Operating Temperature: 0°C to 50°C.• Storage Temperature: -40°C to 85°C.
Note: Internal electronic controller is thermally protected.• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage max.• Approximate Weight: 6 lbs.
Blower Data Unit of MeasurePart Number
Standard Flow117416 M* / 117415 E*
Stages — 3
Vacuum, Maximum (Sealed Vacuum)
in. H2O 154
mBar 385
Pressure, Maximum (Sealed Pressure)
in. H2O 169
mBar 421
Flow Rate, Maximum (Open Flow)
CFM 87
m3/hr 148
Inlet/Outlet Diameter(Dimension “D” above)
inches 1.25
mm 31.75
Length (Dimension “I” above)
inches 2.12
mm 53.85
Length (Dimension “L” above)
inches 6.87
mm 172.21
* These part numbers are available through AMETEK Technical & Industrial Products’ distributors.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
HIGH
-VOL
TAGE
BL
DC B
LOW
ERS
63
5.7” (145mm) DC Bypass Blower1200 Watt, 240 Volt Standard Flow – IntelliGen™
TYPICAL PERFORMANCE
INSTALLATION:• The blower must be secured using mounting tabs, prior to applying power. This is a high speed device with rapid acceleration.• Connections:
All of the Windjammer IntelliGen™ series blowers have a standard 5 pin connector.A mating connector with leads is supplied with single pack units only.Negative pressure applications will exhibit reduced performance.The electronic cooling intake and exhaust must remain unobstructed.Exhaust air must be prohibited from being recycled to inlet air.If blower is to be cycled frequently, the DC speed command should be used.For use in industrial applications, use AMETEK Technical & Industrial Products cooling air fi lters.Note: Utilize AMETEK external EMC fi lter accessory to meet EN61000-4-6 requirement.
• Option Circuit Connections: Please consult with AMETEK for connection details for all optional and custom circuitry.• Utilizes AMETEK’s IntelliGen™ control electronics.
64
5.7” (145mm) DC Bypass Blower1200 Watt, 240 Volt High Flow – IntelliGen™
SEE DETAIL “E” OR “M”
VIEW “B”
SEE VIEW “B”
-B-
ACCESS FOR MECHANICALLYADJUSTED SPEED CONTROL
26°±2°54°30'±2° 33°
SPEEDCONTROL
LC
-B-
M S
LOCATED AS SHOWN ON
BOLT CIRCLE. Ø
(1) Ø HOLE THRU,
-B-
AIREXHAUST
MAX. BOW TYP. BOTH ENDS
90°(2X)
45°
INTAKEAIR
-A-
“I”
“L”
INCH(MM)
2
4
5
3
1
AC INPUT VOLTAGE
GROUND ( )
NOT USEDNOT USED
AC INPUT VOLTAGE
LOW (-)
GROUND ( )
HIGH (+)
2
5
4
3
1
ISOLATED SPEEDCONTROL INPUT}
USE THIS HOLE FORGROUNDING OR EARTHING.REFER TO APPROPRIATELISTING OR REGULATORYAGENCY FOR PROPER METHOD OF GROUNDING OR EARTHING.
"D"2
"D"1
POST HEADER ASSEMBLYDETAIL “M”
POST HEADER ASSEMBLYDETAIL “E”
6.500(165.1)
Ø
(3) Ø HOLES THRU, .168±.003(.4.27±.07)
LOCATED AS SHOWN ON A BOLT CIRCLE.
SMØ.024/.61 A
.168±.003(4.27±.07)
1.04(26.42)
.05(1.3)
.88±.13(22.35±3.3)
3.29±.06(83.57±1.52)
2.79±.08(70.87±2.03)
1.38(35.05)REF.
3.74(95.0)
6.400(162.56)
Ø.024/(.61) A
Ø.015/(.38)
2.40(60.97)
Ø 2.60 MAX. (66.04)Ø 5.88 MAX. (149.4)
NOTES:OPERATING PARAMETERS:• Input Voltage Range: 240 Volt AC Models: 208 to 264 VAC RMS, 50/60 Hz, single phase, maximum running current 10 Amps RMS.
Note: Although this unit contains a lockout feature that detects low voltage conditions, the electronics should not be operated continuously below the input voltage range listed above.
• Isolated Speed Control: Analog Input Voltage Range: 2.2 to +10 VDC nominal, (+12 VDC maximum). Digital Pulse Input: 400 Hz to 20 KHz, 0 to +10 Volt pulse nominal, minimum duty cycle 10%, 0 to +12 Volt maximum.Note: Setting of potentiometer can affect control voltage range and maximum speed can be reached before reaching 10 VDC.
• Speed Control Input Current: Less than 20 mA at 10 Volts input with multi turn internal potentiometer set to minimum (fully counter-clockwise).• Speed Control Drift with Temperature:
Analog Mode: Typ. +/-4% from nominal speed at +23°C.Digital or Direct Mode: Typ. +/-4% from nominal speed at +23°C.
• Operating Temperature: 0°C to 50°C.• Storage Temperature: -40°C to 85°C.
Note: Internal electronic controller is thermally protected.• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage max.• Approximate Weight: 6 lbs.
Blower Data Unit of Measure
Part NumberHigh Flow Ultra Flow
119152 M*119151 E*
119154 M* 119153 E*
119156 E 119155 E*
Stages — 1 2 3 1
Vacuum, Maximum (Sealed Vacuum)
in. H2O 55 92 119 42
mBar 137 229 296 104
Pressure, Maximum (Sealed Pressure)
in. H2O 64 111 140 47
mBar 159 276 348 117
Flow Rate, Maximum (Open Flow)
CFM 203 160 137 274
m3/hr 345 272 233 466
Inlet/Outlet Diameter(Dimension “D” above)
inches 1.75 1.75 1.75 2.75/2.50
mm 44.45 44.45 44.45 69.85/63.50
Length (Dimension “I” above)
inches .47 1.58 1.19 .71
mm 11.94 36.86 30.23 18.03
Length (Dimension “L” above)
inches 5.13 6.19 7.17 5.37
mm 130.30 157.23 182.11 136.40
* These part numbers are available through AMETEK Technical & Industrial Products’ distributors.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
HIGH
-VOL
TAGE
BL
DC B
LOW
ERS
65
5.7” (145mm) DC Bypass Blower1200 Watt, 240 Volt High Flow – IntelliGen™
TYPICAL PERFORMANCE
INSTALLATION:• The blower must be secured using mounting tabs, prior to applying power. This is a high speed device with rapid acceleration.• Connections:
All of the Windjammer IntelliGen™ series blowers have a standard 5 pin connector.A mating connector with leads is supplied with single pack units only.Negative pressure applications will exhibit reduced performance.The electronic cooling intake and exhaust must remain unobstructed.Exhaust air must be prohibited from being recycled to inlet air.If blower is to be cycled frequently, the DC speed command should be used.For use in industrial applications, use AMETEK Technical & Industrial Products cooling air fi lters.Note: Utilize AMETEK external EMC fi lter accessory to meet EN61000-4-6 requirement.
• Option Circuit Connections: Please consult with AMETEK for connection details for all optional and custom circuitry.• Utilizes AMETEK’s IntelliGen™ control electronics.
66
EMI Filter120/240 Volt AC – For use with 250, 400, 800, and 1200 Watt Nautilair and Windjammer Blowers
14.12±.25(358.6±6.4)
4.0±.12 REF.(101.6±3.0)
6.50±.12 REF.(165.1±3.0)
CONNECTOR SPECIFICTO BLOWER TYPE
LINE
LOA
D1.16 MAX. 250W / 400W(29.5)
1.53 MAX 800W / 1200W(38.9)
CONNECTOR SPECIFICTO BLOWER TYPEINCH
(MM)
Ø .189 THRU (4.8)
2.07(52.6)
2.938±.014(74.63±0.35)
Line Side: Connector TerminationDescription Wire Color
Ground GREEN / YELLOW
AC Hot BROWN
AC Hot BLUE
Load Side: Connector TerminationDescription Wire Color
Speed (LO) BLUE
Speed (HI) RED
Ground GREEN / YELLOW
AC Hot BROWN
AC Hot BLUE
Emissions TestingCISPR 11, IEN 55011, I
ISM (Group I) No intentional emissionsIndustrial, Scientific, and Medical Emissions testing for ISM
CISPR 11, IIEN 55011, II
ISM (Group II) intentional ISM emissionsIndustrial, Scientific, and MedicalEmissions testing except certain ISM frequencies
CISPR 14EN 55014
HHAHousehold appliances and similar apparatusBroadband emissions test and for all HHA
CISPR 14EN 55014
Clicks (Discontinuous Noise)Impulsive noise due to transients; Required for all impulsive noise from ISM, ITE, HHA
CISPR 22EN 55022
ITEInformation Technology Equipment; Emissions testing for computers, peripherals, etc.
Immunity TestingIEC 801-2IEC 1000-4-2EN 61000-4-2
ESDElectrostatic dischargeStatic from humans
IEC 801-3IEC 1000-4-3EN 61000-4-3
Radiated RFRF electromagnetic fieldWalkie talkies, transmitters, etc.
IEC 801-4IEC 1000-4-4EN 61000-4-4
EFTElectrical fast transientRelays and motors on and off
IEC 801-5IEC 1000-4-5EN 61000-4-5
Lightning on power lineSurge voltageLightning
IEC 801-6IEC 1000-4-6EN 61000-4-6
Conducted CWConducted induced RF energyPower and signal lines near transmitters
IEC 1000-4-8EN 61000-4-8
Radiated magneticPower frequency magnetic field; Magnetic flux from power lines
IEC 1000-4-11EN 61000-4-11
Voltage dipsDrop in voltage for a short period
IEC 1000-4-11EN 61000-4-11
Voltage interruptsLoss of power for a short period
IEC 1000-4-11EN 61000-4-11
Voltage variationsPower line voltage variations
Part Number 5-90238-1 5-90239-1 5-90238-2 5-90239-2Description Mates with
250 W Series WindjammerMates with
400 W Series WindjammerMates with
800 W Series WindjammerMates with
1200 W Series Windjammer
• Primarily used with the Windjammer product line
• Excellent for meeting European application requirements
• Hard-mount option available
NOTES:Contact your AMETEK Sales Engineer for updates and more information on
this product.This document is for informational purposes only and should not be consid-
ered as a binding description of the products and their performance in all applications. Specifi c dimensions may change based on wattage.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
HIGH
-VOL
TAGE
BL
DC B
LOW
ERS
67
Variable Flow FiltersFor use with AMETEK Windjammer and Nautilair Blowers
NAUTILAIR™
Filter Design Features
AMETEK Technical & Industrial Product’s inlet fi lter is designed to protect the blower and the air distribution system from dust and other air borne particles and contaminants. The compact design, with slip fi t connection; fi ts within the blower’s diameter. Minimal pressure drop through fi lter. This is an ideal fi lter for electronic cooling, material handling, and other pressure systems. The AMETEK Windjammer blower has two models, one for each inlet diameter; the AMETEK Nautilair blower has one model, designed to fi t on all fi ve of the blowers.
Windjammer Filters1-1/4” (31.75mm) Model – P/N 551733* 1-3/4” (44.45mm) Model – P/N 551692*
Inlet Size 1-1/4” � (31.75mm �) 1-3/4” � (44.45mm �)
Pressure Drop 4.8 IWG (11.9 mBar) 3.6 IWG (9 mBar)
Flow Rate 100 CFM (169.9 m3/hr) 180 CFM (305.8 m3/hr)
Efficiency 99+% @ 10 microns
Description Slip Fit with Pleated Polyester Media
Dimensions 4-3/8” (111.1 mm) Diameter x 5-3/4” (146 mm) Height
Nautilair Filter6” (152.4mm) � Model – P/N 551782
Inlet Size 6” � (152.4mm �)
Pressure Drop 0.25 IWG (0.6221 mBar)
Flow Rate 500 CFM (849.5 m3/hr)
Efficiency 97+% @ 2 microns99+% @ 5 microns
Description Slip Fit with Pleated Polyester Media
Dimensions 9-3/4” (247.65mm) Diameter x 10” (254mm) Height
* These part numbers are available through AMETEK Technical & Industrial Products’ distributors.
68
Nautilair™ 7.6” (192mm) Variable Speed Blower24 Volt DC Input, Standard Output
NOTES:• Designed for high effi ciency, low NOx, and CO emission gas-fi red combustion systems.• Brushless DC motor with hall effect sensor feedback.• Internal electronic commutation controller with built in speed control and protection features.• Rubber vibration and shock mounts on motor bracket and bearing system.• Long life, sealed, ball bearings with high temperature grease.• Non sparking, hardened aluminum impeller.• The performance points listed in the charts depict maximum typical performance levels. This is a variable speed product and therefore operates at most perfor-
mance points lower than those listed.• This document is for informational purposes and should not be considered as a binding description of the products or their performance in all applications.
Model Voltage (DC) Flange Type
Version “M”Mechanical on-board
(Potentiometer) speed control
Version “E” Electronic speed
control input 0-10 VDC nominal
Standard Output Models150180-00 24 Large (A) X150181-00 24 Large (A) X150184-00 24 Small (B) X150185-00 24 Small (B) X
INCH(MM)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
HIGH
-VOL
TAGE
BL
DC B
LOW
ERS
69
Nautilair™ 7.6” (192mm) Variable Speed Blower24 Volt DC Input, Standard Output
TYPICAL PERFORMANCE
70
Nautilair™ 7.6” (192mm) Variable Speed Blower120 Volt AC Input, Single Phase, Standard Output/High Output
NOTES:• Designed for high effi ciency, low NOx, and CO emission gas-fi red combustion systems.• Brushless DC motor with hall effect sensor feedback.• Internal electronic commutation controller with built in speed control and protection features.• Rubber vibration and shock mounts on motor bracket and bearing system.• Long life, sealed, ball bearings with high temperature grease.• Non sparking, hardened aluminum impeller.• Utilizes AMETEK’s IntelliGen™ controller electronics• The performance points listed in the charts depict maximum typical performance levels. This is a variable speed product and therefore operates at most per-
formance points lower than those listed.• Available add-on IntelliGen options cards include: 1. Speed control input signal of 15 - 45 VDC @ 500Hz - 10 kHz, and tachometer output ( 2 Pulses / Revolution ) 2. Optional tachometer output ( 3 Pulses / Revolution ) 3. Pressure feedback with pressure sensor/transducer, and tachometer output ( 2 Pulses / Revolution ) 4. RS232 Communications card, compatible with DeviceNet 5. Multiple preset demo card with 4 preset / user adjustable speeds at 4, 6, 8, and 10 VDC speed command input ( +/- 0.5VD ) 6. Speed control input signal of 4-20 mA available• Agency recognized component to UL507 per fi le# E-94403, and CSA C22.2#113 per fi le# LR 43448.
Model Voltage (AC)
FlangeType
PowerConnection
Version “E1”Electronic PWM
speed control input 15-45 VDC @ 500Hz-10KHz
Version “E2”Electronic speed
control input 0-10 VDC nominal
Version “M” Mechanical on-board
(Potentiometer) speed control
Standard Output 150500-00 120 Large (A) 1 X150501-00 120 Large (A) 1 X150502-00 120 Large (A) 1 X150503-00 120 Small (B) 1 X150504-00 120 Small (B) 1 X150505-00 120 Small (B) 1 X
High Output150130-00 120 Large (A) 2 Non-IntelliGen X150131-00 120 Large (A) 2 Non-IntelliGen X150132-00 120 Small (B) 2 Non-IntelliGen X150133-00 120 Small (B) 2 Non-IntelliGen X150134-00 120 Small (B) 3 IntelliGen X150135-00 120 Large (A) 3 IntelliGen X
INCH(MM)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
HIGH
-VOL
TAGE
BL
DC B
LOW
ERS
71
Nautilair™ 7.6” (192mm) Variable Speed Blower120 Volt AC Input, Single Phase, Standard Output/High Output
TYPICAL PERFORMANCE
72
Nautilair™ 7.6” (192mm) Variable Speed Blower240 Volt AC Input, Single Phase, Standard Output/High Output
NOTES:• Designed for high effi ciency, low NOx, and CO emission gas-fi red combustion systems.• Brushless DC motor with hall effect sensor feedback.• Internal electronic commutation controller with built in speed control and protection features.• Rubber vibration and shock mounts on motor bracket and bearing system.• Long life, sealed, ball bearings with high temperature grease.• Non sparking, hardened aluminum impeller.• Utilizes AMETEK’s IntelliGen™ controller electronics• The performance points listed in the charts depict maximum typical performance levels. This is a variable speed product and therefore operates at most perfor-
mance points lower than those listed.• Available add-on IntelliGen options cards include: 1. Speed control input signal of 15 - 45 VDC @ 500Hz - 10 kHz, and tachometer output ( 2 Pulses / Revolution ) 2. Optional tachometer output ( 3 Pulses / Revolution ) 3. Pressure feedback with pressure sensor/transducer, and tachometer output ( 2 Pulses / Revolution ) 4. RS232 Communications card, compatible with DeviceNet 5. Multiple preset demo card with 4 preset / user adjustable speeds at 4, 6, 8, and 10 VDC speed command input ( +/- 0.5VD ) 6. Speed control input signal of 4-20 mA available• Agency recognized component to UL507 per fi le# E-94403, and CSA C22.2#113 per fi le# LR 43448.
Model Voltage (AC)
Flange Type
Version “E1”Electronic PWM
speed control input 15-45 VDC @ 500Hz-10KHz
Version “E2”Electronic speed
control input 0-10 VDC nominal
Version “M” Mechanical on-board
(Potentiometer) speed control
Standard Output Models150520-00 240 Large (A) X150521-00 240 Large (A) X150522-00 240 Large (A) X150523-00 240 Small (B) X150524-00 240 Small (B) X150525-00 240 Small (B) X
High Output Models150140-00 240 Large (A) X150141-00 240 Large (A) X150142-00 240 Small (B) X150143-00 240 Small (B) X150143-06 240 Small (B) X
INCH(MM)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
HIGH
-VOL
TAGE
BL
DC B
LOW
ERS
73
Nautilair™ 7.6” (192mm) Variable Speed Blower240 Volt AC Input, Single Phase, Standard Output/High Output
TYPICAL PERFORMANCE
74
Nautilair™ 8.0” (204mm) Variable Speed Blower120 Volt AC Input, Single Phase, Standard Output
NOTES:• Designed for high effi ciency, low NOx & CO emission gas-fi red combustion systems• Brushless DC motor with hall effect sensor feedback• Internal electronic commutation controller with built in speed control and protection features• Polypropylene housing and impeller• Long life, sealed, ball bearings with high temperature grease• The performance points listed in the charts depict maximum typical performance levels. This is a variable speed product and therefore operates at most perfor-
mance points lower than those listed.• The standard blower model’s speed is controlled through the application of a 0 – 10VDC nominal reference voltage input signal or adjustment of an on-board
mechanical potentiometer, depending on model. • Agency recognized component to UL507 per fi le# E-94403, and CSA C22.2#113 per fi le# LR 43448.• Sealed, molded fan housing• 240VAC, single phase input powered models also available. • This document is for informational purposes and should not be considered as a binding description of the products or their performance in all applications.
Model Voltage (AC)Version “M”
Mechanical on-board (Potentiometer) speed control
Version “E1”Electronic PWM speed control input
15-45 VDC @ 500Hz-10KHz
Standard Output Models117814-00 120 XTBD 220 X
INCH(MM)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
HIGH
-VOL
TAGE
BL
DC B
LOW
ERS
75
Nautilair™ 8.0” (204mm) Variable Speed Blower120 Volt AC Input, Single Phase, Standard Output
TYPICAL PERFORMANCE
76
Nautilair™ 8.9” (225mm) Variable Speed Blower120 Volt AC Input, Single Phase, Standard Output/High Output
BLACK (LINE)
WHITE (NEUTRAL)
BLU (COMMON)PWM IN (BLK)
NOT USEDTACHOUT (WHT)
DC VOLTAGE (RED)
WHITE (NEUTRAL)BLACK (LINE)RED (10V DC SIGNAL)BLUE (COMMON)
2X 6.50±2.60(165.1±25.4)
6X 0.56±.03(14.2±0.76)
AIR INTAKE DETAIL
STANDARD POWER CONNECTION “M” & “E1” PWM CONTROL CONNECTION (OPTIONAL “E1”)
Ø 4.331(110)
.138(3.5)
Ø 3.95±.03(100.3±0.76)
{INTAKE}
Ø 5.68(144.3)
Ø 4.331(110)
9.80±.05(245±1.27)
5.25±.03(133.4±0.76)
2.64±.03(67.1±0.76)
4.724±.010(120±0.25)
4.724±.010(120±0.25)
5.50(139.7)
2.362(60.0)
2.362(60.0)
5.50(139.7)
R.38(9.7)
4X.350(8.9)
4X Ø THRU
6X M8 X 1.25 THREADED HOLES .50 DEEP, EQUALLY SPACED (12.7) AS SHOWN ON A B.C.
MOTOR COOLINGEXHAUST
8.70±.05(221±1.3)
14.00±1.00(355.6±25.4) 7.60
(193)
.118(3.0)MAX.
INCL. BOW-OUT
EXHAUST
28°±1°
43°±3°
(43°)
(28°)
CLCL CL
CONTROLCONNECTION
POWERCONNECTION
SPEEDPOT.
GROUND ( )
5.512(140)
AC INPUT VOLTAGE}
STANDARD POWER CONNECTION “E2”
INCH(MM)
NOTES:• Designed for high effi ciency, low NOx, and CO emission gas-fi red combustion systems.• Brushless DC motor with hall effect sensor feedback.• Internal electronic commutation controller with built in speed control and protection features.• Rubber vibration and shock mounts on motor bracket and bearing system.• Long life, sealed, ball bearings with high temperature grease.• Non sparking, hardened aluminum impeller.• Utilizes AMETEK’s IntelliGen™ controller electronics• The performance points listed in the charts depict maximum typical performance levels. This is a variable speed product and therefore operates at most perfor-
mance points lower than those listed.• Available add-on IntelliGen options cards include: 1. Speed control input signal of 15 - 45 VDC @ 500Hz - 10 kHz, and tachometer output ( 2 Pulses / Revolution ) 2. Optional tachometer output ( 3 Pulses / Revolution ) 3. Pressure feedback with pressure sensor/transducer, and tachometer output ( 2 Pulses / Revolution ) 4. RS232 Communications card, compatible with DeviceNet 5. Multiple preset demo card with 4 preset / user adjustable speeds at 4, 6, 8, and 10 VDC speed command input ( +/- 0.5VD.) 6. Speed control input signal of 4-20 mA available• Agency recognized component to UL507 per fi le# E-94403, and CSA C22.2#113 per fi le# LR 43448.• This document is for informational purposes and should not be considered as a binding description of the products or their performance in all applications.
Model Voltage (AC)Version “E1”Electronic PWM
speed control input 15-45 VDC @ 500Hz-10KHz
Version “E2”Electronic speed control input
0-10 VDC nominal
Version “M” Mechanical on-board
(Potentiometer) speed control
Standard Output Models150330-00 120 X150331-00 120 X150332-00 120 X
High Output Models150230-00 120 X150231-00 120 X150232-00 120 X
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
HIGH
-VOL
TAGE
BL
DC B
LOW
ERS
77
Nautilair™ 8.9” (225mm) Variable Speed Blower120 Volt AC Input, Single Phase, Standard Output/High Output
TYPICAL PERFORMANCE
78
Nautilair™ 8.9” (225mm) Variable Speed Blower240 Volt AC Input, Single Phase, Standard Output/High Output
BLACK (LINE)
WHITE (NEUTRAL) BLU (COMMON)PWM IN (BLK)
NOT USEDTACHOUT (WHT)
DC VOLTAGE (RED)
WHITE (NEUTRAL)BLACK (LINE)RED (10V DC SIGNAL)BLUE (COMMON)
2X 6.50±2.60(165.1±25.4)
6X 0.56±.03(14.2±0.76)
INCH(MM)
AIR INTAKE DETAIL
STANDARD POWER CONNECTION “M” & “E1” PWM CONTROL CONNECTION (OPTIONAL “E1”)
Ø 4.331(110)
.138(3.5)
Ø 3.95±.03(100.3±0.76)
{INTAKE}
Ø 5.68(144.3)
Ø4.331(110)
9.80±.05(245±1.27)
5.25±.03(133.4±0.76)
2.64±.03(67.1±0.76)
4.724±.010(120±0.25)
4.724±.010(120±0.25)
5.50(139.7)
2.362(60.0)
2.362(60.0)
5.50(139.7)
R.38(9.7)4X
.350(8.9)
4X Ø THRU
6X M8 X 1.25 THREADED HOLES .50 DEEP, EQUALLY SPACED (12.7) AS SHOWN ON A B.C.
MOTOR COOLINGEXHAUST
8.70±.05(221±1.3)
14.00±1.00(355.6±25.4) 8.10
(205.7)
.118(3.0)MAX.
INCL. BOW-OUT
EXHAUST
28°±1°
43°±3°
(43°)
(28°)
CLCL CL
CONTROLCONNECTION
POWERCONNECTION
SPEEDPOT.
GROUND ( )
5.512(140)
AC INPUT VOLTAGE}
STANDARD POWER CONNECTION “E2”
NOTES:• Designed for high effi ciency, low NOx, and CO emission gas-fi red combustion systems.• Brushless DC motor with hall effect sensor feedback.• Internal electronic commutation controller with built in speed control and protection features.• Rubber vibration and shock mounts on motor bracket and bearing system.• Long life, sealed, ball bearings with high temperature grease.• Non sparking, hardened aluminum impeller.• Utilizes AMETEK’s IntelliGen™ controller electronics• The performance points listed in the charts depict maximum typical performance levels. This is a variable speed product and therefore operates at most perfor-
mance points lower than those listed.• Available add-on IntelliGen options cards include: 1. Speed control input signal of 15 - 45 VDC @ 500Hz - 10 kHz, and tachometer output ( 2 Pulses / Revolution ) 2. Optional tachometer output ( 3 Pulses / Revolution ) 3. Pressure feedback with pressure sensor/transducer, and tachometer output ( 2 Pulses / Revolution ) 4. RS232 Communications card, compatible with DeviceNet 5. Multiple preset demo card with 4 preset / user adjustable speeds at 4, 6, 8, and 10 VDC speed command input ( +/- 0.5VD ) 6. Speed control input signal of 4-20 mA available• Agency recognized component to UL507 per fi le# E-94403, and CSA C22.2#113 per fi le# LR 43448.• This document is for informational purposes and should not be considered as a binding description of the products or their performance in all applications..
Model Voltage (AC)Version “E1”Electronic PWM
speed control input 12-45 VDC @ 500Hz-10Hz
Version “E2”Electronic speed control input
0-10 VDC nominal
Version “M” Mechanical on-board
(Potentiometer) speed control
Standard Output Models150340-00 240 X150341-00 240 X150342-00 240 X
High Output Models150240-00 240 X150241-00 240 X150242-00 240 X
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
HIGH
-VOL
TAGE
BL
DC B
LOW
ERS
79
Nautilair™ 8.9” (225mm) Variable Speed Blower240 Volt AC Input, Single Phase, Standard Output/High Output
TYPICAL PERFORMANCE
80
Nautilair™ 12.3” (315mm) Variable Speed Blower120 Volt AC Input, Single Phase, Standard Output
NOTES:• Designed for high effi ciency, low NOx, and CO emission gas-fi red combustion systems.• Brushless DC motor with hall effect sensor feedback.• Internal electronic commutation controller with built in speed control and protection features.• Rubber vibration and shock mounts on motor bracket and bearing system.• Long life, sealed, ball bearings with high temperature grease.• Non sparking, hardened aluminum impeller.• The performance points listed in the charts depict maximum typical performance levels. This is a variable speed product and therefore operates at most
performance points lower than those listed.• Available add-on expansion cards include: 1. Available speed control input signals are PWM 15-45VDC @ 500-10K kHz at tachometer output (2 or 3 pulses per revolution), 0-10 VDC, mechanical
(Potentiometer) and 4-20 mA 2. Optional tachometer output ( 3 Pulses / Revolution ) 3. Pressure feedback with pressure sensor/transducer, and tachometer output ( 2 Pulses / Revolution ) 4. RS232 Communications card, compatible with DeviceNet 5. Multiple preset demo card with 4 preset / user adjustable speeds at 4, 6, 8, and 10 VDC speed command input ( +/- 0.5VD )• This document is for informational purposes and should not be considered as a binding description of the products or their performance in all applications.
Model Voltage (AC)Version “E1”Electronic PWM
speed control input 15-45 VDC @ 500Hz-10KHz
Version “E2”Electronic speed control input
0-10 VDC nominal
Version “M” Mechanical on-board
(Potentiometer) speed control
Standard Output Models150530-00 120 X150531-00 120 X150532-00 120 X
INCH(MM)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
HIGH
-VOL
TAGE
BL
DC B
LOW
ERS
81
Nautilair™ 12.3” (312mm) Variable Speed Blower120 Volt AC Input, Single Phase, Standard Output
TYPICAL PERFORMANCE
82
Nautilair™ 12.3” (315mm) Variable Speed Blower240 Volt AC Input, Single Phase, Standard Output
NOTES:• Designed for high effi ciency, low NOx, and CO emission gas-fi red combustion systems.• Brushless DC motor with hall effect sensor feedback.• Internal electronic commutation controller with built in speed control and protection features.• Rubber vibration and shock mounts on motor bracket and bearing system.• Long life, sealed, ball bearings with high temperature grease.• Non sparking, hardened aluminum impeller.• The performance points listed in the charts depict maximum typical performance levels. This is a variable speed product and therefore operates at most
performance points lower than those listed.• Available speed control input signals are PWM 15-45VDC @ 500-10K kHz at tachometer output (2 or 3 pulses per revolution), 0-10 VDC, mechanical
(Potentiometer) and 4-20 mA• Available add-on expansion cards include: 1. Optional tachometer output ( 3 Pulses / Revolution ) 2. Pressure feedback with pressure sensor/transducer, and tachometer output ( 2 Pulses / Revolution ) 3. RS232 Communications card, compatible with DeviceNet 4. Multiple preset demo card with 4 preset / user adjustable speeds at 4, 6, 8, and 10 VDC speed command input ( +/- 0.5VD )• This document is for informational purposes and should not be considered as a binding description of the products or their performance in all applications.
Model Voltage (AC)Version “E1”Electronic PWM
speed control input 15-45 VDC @ 500Hz-10KHz
Version “E2”Electronic speed control input
0-10 VDC nominal
Version “M” Mechanical on-board
(Potentiometer) speed control
Standard Output Models150540-00 240 X150541-00 240 X150542-00 240 X
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
HIGH
-VOL
TAGE
BL
DC B
LOW
ERS
83
Nautilair™ 12.3” (312mm) Variable Speed Blower240 Volt AC Input, Single Phase, Standard Output
TYPICAL PERFORMANCE
WINDJAMMER® IntelliGen™ Blower
Interface Control Options
DescriptionThe Windjammer IntelliGen Series of Brushless DC Centrifugal Blowers utilizes the latest programmable micro-controller technology to provide a wide selection of confi guration options to control the blower. The blower can be confi gured with the following control functions for seamless integration into your blower application.
Available Control Options: • Preset Set Point This option is ideal for applications requiring a fi xed precise blower set point which does not require manual calibration or adjustment in the application.
• Internal Blower Setpoint Control This option is ideal for applications that require a fi xed blower set point which requires manual adjustment or calibration in the application via a trim pot residing on the blower.
• Potentiometer Control This option is designed for applications requiring variable speed blower control via an externally mounted potentiometer.
• External Blower Setpoint Control This option is ideal for applications requiring variable speed blower control using an external 0V-10V electronic signal to control blower set point.
• Isolated Control Logic Inputs This option is designed for applications requiring a limited number of precise blower set points. Two blower control logic inputs are used to conveniently select up to four precise pre-programmed blower set points.
• Precision Analog Reference Isolation Amplifier This option can support a 0-20 mA or 4-20 mA current loop blower speed reference signal. The amplifi er can be used as a precision true 0-10V reference signal, providing extended speed range to the blower.
• PWM Control Input and Tach Output This option is designed for applications that require external control and monitoring of blower speed. The blower accepts a pulse width modulated input signal to control blower set point and provides a 2 pulse per revolution output signal for monitoring blower speed.
• Blower Status Contact This option provides an external contact to provide a simple and convenient indication of blower operating status and blower fault diagnostics external to the blower.
• Precision Analog Sensor Isolation Amplifier This option is designed for applications requiring precise regulation of air fl ow, air pressure, temperature, or other measurable parameters, via feedback from an external sensor. The isolation amplifi er accepts direct connection to external sensors that have a variety of signal output types.
Control Option Selection Guide
84
85AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
BLDC
FAN
S &
BLO
WER
SIM
PELL
ERST
YLE
Brushless DC FANS and
impeller-style blowersAMETEK Technical and Industrial Products’ Brushless DC Fans and Impeller-Style Blowers
offer multi-speed aerodynamic performances for all types of high airfl ow applications. Our
standard designs come with fully integrated electronics and are available in various input
voltages including 12 and 24 VDC (13.8 and 27.6 VDC). Environmentally resistant designs
are also available for those applications that may require exposure to natural elements. With
airfl ow exceeding 1900 CFM, these products combine the long life expectations of brushless
DC products with maximum cooling and air moving capability.
Air Mover Style Operating VoltageDC
Flow at Free DeliveryCFM (m3/hr)
RTP10 Fan 12/24 910/1015 (1546/1724)
RTP14 Fan 24 1641 (2788)
RTP16 Fan 12/24 1700/1720 (2888/2922)
RTP16S Fan 12/24 1800/1920 (3058/3262)
RTP1300 Blower 12/24 378 (642)
RTP1400 Blower 12/24 568/619 (964/1051)
RTP1600 Blower 12/24 877/872 (1490/1482)
RTP1700 Blower 24 736 (1250)
86
RTP10 Brushless DC Fan12/24 VDC
Blower Data Unit of MeasurePart Number
150077-01* PULLER 150113-01* PULLER
Voltage Input VDC 12 (actual 13.8) 24 (actual 27.6)
Flow Rate, Maximum (Open Flow)
CFM 910 1015
m3/hr 1546 1724
4X.36
(9.14)
2X5.14
(130.56)
10.72(272.29)
4X THRU Ø .25 (Ø 6.35)
SPACED AS SHOWN
Ø 11.28(Ø 286.51)
1X 16 GA. (YEL: 0 TO +10.0 VDC)2X 14 GA. (RED: +; BLACK: -)XLPE, 300V, 125°C
3X 0.38±0.12(9.65±3.05)
3X 24.0±1.00(609.6±25.4)
4.85(123.19)
2.88(73.15)
.86(21.84)
11.87(301.50)
Ø 3.00±0.01(Ø 76.20±0.25)
AIR FLOW
PULLER
INCH(MM)
NOTES: • These fans can be equipped with an option allowing for up to four distinct speed settings. Please inquire with the Marketing/Sales Department for specifi c
set points.• Temperature: Working Ambient Air: -40°C to 70°C, Storage Air: -40°C to 85°C.• Nominal Input Voltage: 12 VDC is 9 to 18 VDC, 24 VDC is 18 to 32 VDC; test performed at 13.8 VDC for 12 VDC models, and 27.6 VDC for 24 VDC
models.• Environmentally resistant design. Please discuss specifi c operating environment with the Marketing/Sales Department.• Approximate Weight: 6 lbs.
* These part numbers are available through AMETEK Technical & Industrial Products’ distributors.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
BRUS
HLES
SDC
FAN
S
87
RTP10 Brushless DC Fan12/24 VDC
TYPICAL PULLER PERFORMANCE
Test data is corrected to “standard conditions” – 0.075 lb./ft3 air density (29.92 Hg at 70°F).
88
RTP14 Brushless DC Fan24 VDC
Blower Data Unit of MeasurePart Number
150078-01* PULLER
Voltage Input VDC 24 (actual 27.6)
Flow Rate, Maximum (Open Flow)
CFM 1641
m3/hr 2788
4X.36
(9.14) 2X7.08
(179.83)
2X14.68
(372.87)
13.97(354.84)
4X THRU Ø .25
(Ø 6.35)SPACED AS SHOWN
Ø 14.68(Ø 372.87)
1X 16 GA. (YEL: 0 TO +10.0 VDC)2X 14 GA. (RED: +; BLACK: -)XLPE, 300V, 125°C
3X 0.38±0.12(9.65±3.05)
3X 24.0±1.00(609.6±25.4)
5.85(148.59)
3.65(92.71)
.86(21.84)
Ø 3.00±0.01(Ø 76.20±0.25)
AIR FLOW
PULLER
INCH(MM)
NOTES: • These fans can be equipped with an option allowing for up to four distinct speed settings. Please inquire with the Marketing/Sales Department for specifi c
set points.• Temperature: Working Ambient Air: -40°C to 70°C, Storage Air: -40°C to 85°C.• Voltage Range: 24 VDC = 18 to 32 VDC.• Environmentally resistant design. Please discuss specifi c operating environment with the Marketing/Sales Department.• Approximate Weight: 7 lbs.
* These part numbers are available through AMETEK Technical & Industrial Products’ distributors.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
BRUS
HLES
SDC
FAN
S
89
RTP14 Brushless DC Fan24 VDC
TYPICAL PULLER PERFORMANCE
Test data is corrected to “standard conditions” – 0.075 lb./ft3 air density (29.92 Hg at 70°F).
90
RTP16 Brushless DC Fan12/24 VDC
Blower Data Unit of MeasurePart Number
150079-01* PULLER 150115-01* PULLER
Voltage Input VDC 12 (actual 13.8) 24 (actual 27.6)
Flow Rate, Maximum (Open Flow)
CFM 1700 1720
m3/hr 2888 2922
Ø 3.00±0.01(Ø 76.20±0.25)
24.0±1.0(609.6±25.4)
3X
0.38±0.12(9.65±3.05)
3X
Ø 16.75(Ø 425.25)
16.56(420.62)2X
8.08(205.23)
16.08(408.43)
2X
0.86(21.84)
3.65(92.71)
5.94(150.88)
1X 16 GA. (YEL: 0 TO +10.0 VDC)2X 14 GA. (RED: +; BLACK: -)XLPE, 300V, 125°C
4X THRUØ .25
(Ø 6.35)SPACED
AS SHOWN
AIR FLOW
PULLER
INCH(MM)
NOTES: • These fans can be equipped with an option allowing for up to four distinct speed settings. Please inquire with the Marketing/Sales Department for specifi c
set points.• Temperature: Working Ambient Air: -40°C to 70°C, Storage Air: -40°C to 85°C.• Voltage Range: 12 VDC = 9 to 18 VDC; 24 VDC = 18 to 32 VDC.• Environmentally resistant design. Please discuss specifi c operating environment with the Marketing/Sales Department.• Approximate Weight: 7 lbs.
* These part numbers are available through AMETEK Technical & Industrial Products’ distributors.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
BRUS
HLES
SDC
FAN
S
91
RTP16 Brushless DC Fan12/24 VDC
TYPICAL PULLER PERFORMANCE
Test data is corrected to “standard conditions” – 0.075 lb./ft3 air density (29.92 Hg at 70°F).
92
RTP16S Brushless DC Fan12/24 VDC
Blower Data Unit of MeasurePart Number
150083-01* PULLER 150116-01* PULLER
Voltage Input VDC 12 (actual 13.8) 24 (actual 27.6)
Flow Rate, Maximum (Open Flow)
CFM 1800 1920
m3/hr 3058 3262
Ø 3.00±0.01(Ø 76.20±0.25)
24.0±1.0(609.6±25.4)
3X
0.38±0.12(9.65±3.05)
3X
16.66(423.16)
12.84(326.14)
12.84(326.14)
15.66(397.76)
0.86(21.84)
3.58(90.93)
6.54(166.12)
1X 16 GA. (YEL: 0 TO +10.0 VDC)2X 14 GA. (RED: +; BLACK: -)XLPE, 300V, 125°C
4X THRUØ .25
(Ø 6.35)SPACED
AS SHOWN
AIR FLOW
PULLER
INCH(MM)
NOTES: • These fans can be equipped with an option allowing for up to four distinct speed settings. Please inquire with the Marketing/Sales Department for specifi c
set points.• Temperature: Working Ambient Air: -40°C to 70°C, Storage Air: -40°C to 85°C.• Voltage Range: 12 VDC = 9 to 18 VDC; 24 VDC = 18 to 32 VDC.• Environmentally resistant design. Please discuss specifi c operating environment with the Marketing/Sales Department.• Approximate Weight: 7 lbs.
* These part numbers are available through AMETEK Technical & Industrial Products’ distributors.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
BRUS
HLES
SDC
FAN
S
93
RTP16S Brushless DC Fan12/24 VDC
TYPICAL PULLER PERFORMANCE
Test data is corrected to “standard conditions” – 0.075 lb./ft3 air density (29.92 Hg at 70°F).
94
RTP1300 Brushless DC Impeller Style Blower12/24 VDC
Blower Data Unit of MeasurePart Number
150117-00 150222-00
Voltage Input VDC 12 (actual 13.8) 24 (actual 27.6)
Flow Rate, Maximum (Open Flow)
CFM 378 378
m3/hr 642 642
NOTES:• These blowers can be equipped with an option allowing for up to four distinct speed settings. Please inquire with the Marketing/Sales Department for
specifi c set points.• Temperature: Working Ambient Air: -40°C to 70°C, Storage Air: -40°C to 85°C.• Voltage Range: 12 VDC = 9 to 18 VDC; 24 VDC = 18 to 32 VDC.• Environmentally resistant design. Please discuss specifi c operating environment with the Marketing/Sales Department.• Approximate Weight: 7 lbs.
0.38±0.12(9.65±3.05)
4.47(113.54)
2.24(56.90)
5.0(127.0)
0.12(3.05)
4.10(104.14)
2X OPENING
2.10(53.34)
2X OPENING
13.86(352.04)
13.25(336.55)
8.25(209.55)
5.0(127.0)
0.31(7.87)
4.0(101.6)
3.5(88.9)
4X
8X Ø 0.22 THRU (Ø 5.59)
2X 0.25 (6.35)
(304.8±25.4) MEASURED PERPENDICULAR TO MOTOR BODY
4X
2X 14 GA. (RED: + , BLACK: - )2X 16 GA. (YELLOW & ORANGE)XLP, 300V, 125°C
INCH(MM)
12.0±1.0
2X 0.66 (15.2)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
IMPE
LLER
-STY
LE
BLOW
ERS
95
RTP1300 Brushless DC Impeller Style Blower12/24 VDC
TYPICAL PERFORMANCE
Test data is corrected to “standard conditions” – 0.075 lb./ft3 air density (29.92 Hg at 70°F).
96
RTP1400 Brushless DC Impeller Style Blower12/24 VDC
0.38±0.12(9.65±3.05)
5.49(139.45)
2.35(59.69)
0.44(11.18)
.826(20.98)
4.10(104.10)
OPENING
1.484(37.69)
1.968(49.99)
6.593(167.46)
12.86(326.64)
1.51(38.35)
2.301(58.45)
5.30(134.62)(REF.)
24X Ø.188
THRU(4.77)
1.219(30.96)
.889(22.58) 1.642
(41.71)
2.674(67.92)
350.01(13.78)
3.099(78.71)
2X
4.30(109.22)
2X
2.67(67.82)
2X
5.30(134.62)
3.84(97.54)
3.58(90.93)
4X
(304.8±25.4) MEASURED PERPENDICULAR TO MOTOR BODY
4X
2X 14 GA. (RED: +, BLACK: -)2X 16 GA. (YELLOW & ORANGE)XLP, 300V, 125°C
INCH(MM)
12.0±1.0
Blower Data Unit of MeasurePart Number
150229-00 150221-00
Voltage Input VDC 12 (actual 13.8) 24 (actual 27.6)
Flow Rate, Maximum (Open Flow)
CFM 568 619
m3/hr 964 1051
NOTES:
• These blowers can be equipped with an option allowing for up to 4 distinct speed settings. Please inquire with the Marketing/Sales Department for specifi c set points.
• Temperature: Working Ambient Air: -40°C to 70°C, Storage Air: -40°C to 85°C.• Voltage Range: 12 VDC = 9 to 18 VDC; 24 VDC = 18 to 32 VDC.• Environmentally resistant design. Please discuss specifi c operating environment with the Marketing/Sales Department.• Approximate Weight: 9 lbs.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
IMPE
LLER
-STY
LE
BLOW
ERS
97
RTP1400 Brushless DC Impeller Style Blower12/24 VDC
TYPICAL PERFORMANCE
Test data is corrected to “standard conditions” – 0.075 lb./ft3 air density (29.92 Hg at 70°F).
98
RTP1600 Brushless DC Impeller Style Blower12/24 VDC
17.69±0.02(449.32±0.51)
2.18±0.02(55.37±0.51)
2X
3.20(81.28)
2X
1.00(25.4)
4X
2X 3.95
INLET (100.33)
2X 4.17
(161.04)
2X 0.30
(7.62)2X 5.94
(150.88)16.80
(426.72)
2X 7.34
(186.44)
2X 4.17
(105.92)
2X 3.70
(93.98)
2X 3.17
(80.52) 4X 0.16
(4.06)
4X 2.81
(71.37)
4X 0.38±0.13
(9.65±3.05)
12.00±1.00(304.8±25.4)MEASURED
PERPENDICULARTO MOTOR BODY
LEADS EXITWITHIN
QUANDRANTSHOWN
2X 3.10
(78.74)
4X Ø .285
THRU, SPACED AS SHOWN (7.24) INCH(MM)
2X 14 GA. (RED: +, BLACK: -)2X 16 GA. (YELLOW & ORANGE)XLP, 300V, 125°C
Blower Data Unit of MeasurePart Number
150225-00 150226-00
Voltage Input VDC 12 (actual 13.8) 24 (actual 27.6)
Flow Rate, Maximum (Open Flow)
CFM 877 872
m3/hr 1490 1482
NOTES:
• These blowers can be equipped with an option allowing for up to 4 distinct speed settings. Please inquire with the Marketing/Sales Department for specifi c set points.
• Temperature: Working Ambient Air: -40°C to 70°C, Storage Air: -40°C to 85°C.• Voltage Range: 12 VDC = 9 to 18 VDC; 24 VDC = 18 to 32 VDC.• Environmentally resistant design. Please discuss specifi c operating environment with the Marketing/Sales Department.• Approximate Weight: 10 lbs.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
IMPE
LLER
-STY
LE
BLOW
ERS
99
RTP1600 Brushless DC Impeller Style Blower12/24 VDC
TYPICAL PERFORMANCE
Test data is corrected to “standard conditions” – 0.075 lb./ft3 air density (29.92 Hg at 70°F).
100
RTP1700 Brushless DC Impeller Style Blower24 VDC
INCH(MM)
(45°)
3.84(97.54)
0.38(9.65)
62.74(2.47)
65.79(2.59)
63.50(2.50)
2.70(68.58)
4X 0.31
(7.87)4X 0.39
(9.91)
4X 1.71
(43.43)
4X 1.03
(26.16)
4X 0.75
(19.05)
4X 0.43
(10.92)
4X 4.32
(109.73)
2X 5.30
(134.62)
2X 5.63
(143.00)
2X 2.37
(60.20)
2X 5.51
(139.95)
2X 0.20
(5.08)
2X 4.94
(125.48)
2X 16.66±0.03
(423.16±0.76)
4X 0.38±0.12
(9.65±3.05)
4X 12.00±1.00
(304.8±25.4)
2X 0.50
(12.7)
2X 2.31
(58.7)OPENING
2X 0.34
(8.6)
2X Ø 3.81
X 12.7
DEEP
(Ø 0.15) (0.50)
2X 5.11
OPENING
(129.8)
YELLOWORANGE
BLACKRED
2X 14 GA. (RED: +, BLACK: -)2X 16 GA. (ORANGE, YELLOW)
XLP, 300V, 125°C
Blower Data Unit of MeasurePart Number
150220-00
Voltage Input VDC 24 (actual 27.6)
Flow Rate, Maximum (Open Flow)
CFM 736
m3/hr 1250
NOTES:
• These blowers can be equipped with an option allowing for up to 4 distinct speed settings. Please inquire with the Marketing/Sales Department for specifi c set points.
• Temperature: Working Ambient Air: -40°C to 70°C, Storage Air: -40°C to 85°C.• Voltage Range: 24 VDC = 18 to 32 VDC.• Environmentally resistant design. Please discuss specifi c operating environment with the Marketing/Sales Department.• Approximate Weight: 10 lbs.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
IMPE
LLER
-STY
LE
BLOW
ERS
101
RTP1700 Brushless DC Impeller Style Blower24 VDC
TYPICAL PERFORMANCE
Test data is corrected to “standard conditions” – 0.075 lb./ft3 air density (29.92 Hg at 70°F).
NOTES
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
102
103AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
PUM
PSPUMPSOur Seal-less Brush and Brushless Water Circulating Pumps offer four basic pump/motor
designs from 10 GPM (37.9 L/min) to 26 GPM (98.4 L/min) in either 12 VDC or 24 VDC motor
designs. Variable speed is available upon request for the brushless designs. The seal-less
pump design is magnetically coupled which provides for a leak-proof pump. There are
no rotating wet seals to wear out and leak. Detailed pump information is provided on the
individual product sheets. AMETEK seal-less pumps are not designed for, and should not be
used in, life sustaining applications.
StyleNominal Voltage
Nominal Flow*GPM (L/min)
Maximum HeadFeet (Meter)
10 GPM Brush13.8 7 (26.5)
10 (3.05)27.6 7 (26.5)
12 GPM Brushless13.8 9 (34.1)
20 (6.1)27.6 9 (34.1)
18 GPM Brushless13.8 16 (60.6)
10 (3.05)27.6 16 (60.6)
26 GPM Brushless 27.6 18 (68.1) 20 (6.1)
* Represents maximum fl ow at 85°C ambient air temperature.
104
10 Gallon Seal-less Pump, Brush Motor
CA
UTI
ON
2X
OUTLET
BARB FITTING, BRASS,FOR I.D. HOSE
SEE NOTE 2
Ø 1.00(Ø 25.4)
4X .406±.010(10.31±0.25)
4X .281(7.14)
1.625±.010(117.48±0.25)
1.625±.010(117.48±0.25)
3.96±.06(100.58±1.52)
2.25±.02(57.15±0.51)
.75±.06(19.05±1.52)
3.00±.02(76.20±0.51)
.36(9.14)
NOMINAL RATINGS
VOLTAGE: +27.6 VDC +13.8 VDC FLOW: 10 GPM 10 GPM AMBIENT TEMP RANGE: -40°C TO +85°C -40°C TO +85°C SPEED: 3200 RPM 3200 RPM CURRENT: 3.0 AMPS 6.0 AMPS WEIGHT: 6.0 LB / 2.72 kg 6.0 LB / 2.72 kg
“RED” LEAD: +27.6 VDC +13.8 VDC “BLACK” LEAD: RETURN RETURN
12 AWG XLPE LEAD DESIGNATION
INCH(MM)
150163-31(6:00 BLAST)
150163-11(12:00 BLAST)
150163-21(3:00 BLAST)
150163-41(9:00 BLAST)
BLAST DIRECTION DETAIL
NOTES:1. MOTOR HOUSING AND MOUNTING BRACKET MATERIAL: CRS MOTOR END CAPS MATERIAL: ALUMINUM AND/OR ZINC PUMP HOUSING: POLYSULFONE PLASTIC2. CAUTION: DO NOT RE-TORQUE INLET FITTING DURING FIELD I INSTALLATION OR REPAIR COULD RESULT IN PUMP HOUSING
DAMAGE.
5.14±.06(130.56±1.52)
2.38(60.45)
1.11(28.19)
.75(19.05)
.09(2.29)
Ø .80(Ø 20.32)
Ø .76(Ø 19.30)
CAUTION LABELSEE NOTE 2
10.0±2.0 (254.8±50.8)
Ø 1.36(Ø 34.54)
Ø 3.27(Ø 83.06)
.58(14.73)
3.42±.06(86.87±1.52)
4.68±.06(118.87±1.52)
4.68±.06(118.87±1.52)
1.18±.06(29.97±1.52)
Ø 1.01(Ø 25.65)
Model Voltage VoltageRange
FlowGPM (L/min) Current Speed Ambient Temperature
Range
150163-11 13.8 VDC 9 - 18 VDC 10 (37.9) 6 Amps 3200 RPM -40°C to 85°C
150162-11 27.6 VDC 18 - 32 VDC 10 (37.9) 3 Amps 3200 RPM -40°C to 85°C
NOTES:
• Motor design characteristics are based on an operating environment of 85°C.• Nominal and maximum performance fi gures are based on a winding temperature of 105°C.• This product is designed for medium duty harsh environment applications such as shuttle bus and other medium duty transit bus applications.• This product is environmentally resistant to hot water spray, rain, humidity, salt, fog, shock, and vibrations associated with vehicle applications.• The seal-less pump is leak proof and features a magnetic coupling with no wet seal to wear or replace.• The brush motor is removable from the pump without draining the coolant system.• Approximate typical weight: 6 lbs.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
PUM
PS
105
10 Gallon Seal-less Pump, Brush Motor
TYPICAL PERFORMANCE
106
12 Gallon Seal-less Pump, Brushless Motor
NOTES:
• Motor design characteristics are based on an operating environment of 85°C.• Nominal and maximum performance fi gures are based on a winding temperature of 105°C.• This product is designed for medium duty harsh environment applications such as shuttle bus and other medium duty transit bus applications.• This product is environmentally resistant to hot water spray, rain, humidity, salt, fog, shock, and vibration associated with vehicle applications.• The seal-less pump is leak proof and features a magnetic coupling with no wet seal to wear or replace.• The brushless motor is removable from the pump without draining the coolant system and has no brushes to be replaced. The motor is electronically
commutated.• Approximate typical weight: 8 lbs.
4X 2.00
(50.80) Ø 0.81
(20.62)
3.0 REF.(76.2)
0.06(1.52)
2.24(56.90)
Ø 3.00±0.01(Ø 76.20±0.25)
1.84±0.06(46.74±1.52)
1.625±0.10(117.48±0.25)
3.96±0.06(100.58±1.52)
1.625±0.10(117.48±0.25)
2.25±0.02(57.15±0.51)
3.00±0.02(76.20±0.51)
4.29±0.06(108.97±1.52)
5.79±0.06(147.07±1.52)
2.00±0.06(50.80±1.52)
.093±0.10(2.36±0.25)
5.62±0.06(142.75±1.52)
1.19±0.06(30.23±1.52)
3.50 REF.(88.90)
1.46(37.08)
Ø 3.0±1.0(Ø 152.4±25.4)
Ø 1.02(Ø 25.65)
(RED)
0.88(22.35)
CA
UT
ION
CAUTIONLABEL
OUTLET
BLAST DIRECTION DETAIL
150042-11(12:00 BLAST)
150042-21(3:00 BLAST)
150042-31(6:00 BLAST)
150042-41(9:00 BLAST)
Ø 0.81
(19.05)
Ø 0.84
(21.34)
4X .406±.010
(10.31±0.25)
4X .281
(7.14)
2X 12.00±1.00
(304.8±25.4)
2X 14 GA. LEADSXLPE, 300V, 125°CUS 3266/CSA 1252
REF. LEAD DESIGNATION
1.29±0.01(32.77±0.25)INCH
(MM)
BARB FITTING,BRASS, FOR
Ø 1.00 I.D. HOSE(Ø 25.4)
14 AWG LEAD DESIGNATION“RED” LEAD: +13.8 VDC
“BLACK” LEAD: RETURN
Model Voltage VoltageRange
FlowGPM (L/min) Current Speed Ambient Temperature
Range
150042-X1 13.8 VDC 9 - 18 VDC 12 (45.4) 12 Amps 3300 RPM -40°C to 85°C
150011-X1 27.6 VDC 18 - 32 VDC 12 (45.4) 6 Amps 3300 RPM -40°C to 85°C
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
PUM
PS
107
12 Gallon Seal-less Pump, Brushless Motor
TYPICAL PERFORMANCE
DURA-TEK
108
18 Gallon Seal-less Pump, Brushless Motor
NOTES: • Motor design characteristics are based on an operating environment of 85°C.• Nominal and maximum performance fi gures are based on a winding temperature of 105°C.• This product is designed for heavy duty harsh environment applications such as heavy duty transit bus applications. • This product is environmentally resistant to hot water spray, rain, humidity, salt, fog, shock, and vibration associated with vehicle applications.• The seal-less pump is leak proof and features a magnetic coupling with no wet seal to wear or replace.• The brushless motor is removable from the pump without draining the coolant system and has no brushes to be replaced. The motor is electronically
commutated.• Approximate typical weight: 15 lbs.
STAMPING DATA
CORRUGATED LOOM
CONNECTOR WEATHERPACKPACKARD NO. 12010973OR EQUIVALENT
4X 3/8-16 UNC-2B X 0.50 DEEPEQUALLY SPACED AS SHOWNON A Ø 2.312 BOLT CIRCLE
12.0±1.0(304.8±25.4)
3.50±0.03(88.90±0.8)(MOTOR FLATS)
4.62(117.4)
6.0(152.4)
2.74(69.6)
Ø 3.094(Ø 78.59)
1.48±0.10(37.6±2.5)
2.312(58.73)
1.35(34.3)
2.12(53.8)
1.81(46.0)
2X 3/8-16 UNC-2B X 0.38 DEEP (9.7)SPACED AS SHOWN
4X1.00
(25.4)
2X R 0.38
(9.7)
4X 2.44
(62.0)
Ø 1.25 INLET (Ø 31.8)
.45 REF (11.4)
.23 REF (5.84)
Ø
0.88 OUTLET (22.4)
Ø 3.89±.03
(98.8±0.8) (MOTOR)
150178-11-0(12:00 BLAST)
150178-21-0(3:00 BLAST)
150178-31-0(6:00 BLAST)
150178-41-0(9:00 BLAST)
BLAST DIRECTION OPTIONS
IN(MM)
B A (–) RETURN (+) 27.6 VDC BLACK RED
HOOK-UP DIAGRAM
B A
ROTATION
Model Voltage VoltageRange
FlowGPM (L/min) Current Speed Ambient Temperature
Range
150299-X1 13.8 VDC 9 - 18 VDC 18 (68.1) 10 Amps 3100 RPM -40°C to 85°C
150178-X1 27.6 VDC 18 - 32 VDC 18 (68.1) 5 Amps 3100 RPM -40°C to 85°C
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
PUM
PS
109
18 Gallon Seal-less Pump, Brushless Motor
TYPICAL PERFORMANCE
110
26 Gallon Seal-less Pump, Brushless Motor
150198-11(12:00 BLAST)
150198-21(3:00 BLAST)
150198-31(6:00 BLAST)
150198-41(9:00 BLAST)
4X 0.355±0.015
(9.02±0.38)
4X 1.060±0.015
(26.92±0.38)
4X 2.44
(61.98)
2X R 0.38
(9.65)
4X R 0.25
(6.35)
0.38(9.65)
0.23(5.84)
0.97(24.6)
2X
2.13(54.1)
3.00(76.2)
0.18(4.57)
Ø 5.25(Ø 133.35)
Ø 3.094(Ø 78.59)
2.64(67.1)
1.40(35.56)
0.32(8.13)
4.59(116.6)
6.76(171.7)
2.312(58.72)
0.47(11.94)
3.68(93.47)
4.25(107.95)
2.750(69.85)
1.40(35.6)
0.71(18.0)
5.68(144.27)
1.35(34.29)
1.81(45.97)
INCH(MM)
4X 3/8-16 UNC-2B X 0.50
DEEP
(12.7)
EQUALLY SPACED AS SHOWN
ON A Ø 2.312
BOLT CIRCLE (Ø 58.72)
CORRUGATEDLOOM
2X 12 AWG XLPE LEADS WEATHER PACK2 WAY CONNECTOR PACKARD PN 120109732X MALE TERMINAL PACKARD PN 12124587
3X CABLE SEAL PACKARD PN 12015193PIN A: +27.6 VDCPIN B: - RETURN
SEPARATION POINT
NAMEPLATE
18.0 +2.0
-0.0
(457.2 +50.8 ) -00.0
Ø 1.25 INLET (Ø 31.75)
2X 3/8-16 UNC-2B X 0.38 DEEP (9.65)
Ø 0.88 OUTLET (Ø 22.35)
1.48±0.10(37.59±0.25)
4.56±0.60(115.82±1.52)OVER FLATS
BLAST DIRECTION OPTIONS
NOTES: • Motor design characteristics are based on an operating environment of 85°C.• Nominal and maximum performance fi gures are based on a winding temperature of 105°C.• This product is designed for heavy duty harsh environment applications such as heavy duty transit bus applications.• This product is environmentally resistant to hot water spray, rain, humidity, salt, fog, shock, and vibration associated with vehicle applications.• The seal-less pump is leak proof and features a magnetic coupling with no wet seal to wear or replace.• The brushless motor is removable from the pump without draining the coolant system and has no brushes to be replaced. The motor is electronically
commutated.• Approximate typical weight: 25 lbs.
Model Voltage VoltageRange
FlowGPM (L/min) Current Speed Ambient Temperature
Range
150198-X1 27.6 VDC 18 - 32 VDC 26 (98.4) 10 Amps 3850 RPM -40°C to 85°C
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
PUM
PS
111
26 Gallon Seal-less Pump, Brushless Motor
TYPICAL PERFORMANCE
NOTES
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
112
113AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
controllersAll AMETEK brushless DC motors and blowers require a motor/blower controller to operate.
Many of these AMETEK BLDC motors and blowers feature a built in, integrated controller that
takes the DC input from a power supply or battery and processes it into phase drive signals
that are used to commutate the motor.
Motors and blowers that require low voltage DC input (11 to 52 volts) that do not come
equipped with an integrated, onboard controller, require one of the external controllers
described in this section.
Controller details, features, motor compatibility, recommended connector/wiring
harnesses, and a handy motor/blower sizing form are also located in this section.
CONT
ROLL
ERS
114
5 Amp BLDC Motor/Blower Controller
1
INCH(MM)
MAX.
1.70(43.2)
1.00(25.4)
MAX.
0.98(24.9)
MAX..156±.010(4±0.25)2X
.53±.01(13.5±0.25)
2X
2.190±.015(4.83±0.38)2X
.190±.010(4.83±0.25)4X
3.25±.01(82.6±0.25)
MOLEX 6373 VERTICAL FRICTION LOCK HEADERSQUARE PIN, .100 CENTER,2 CIRCUIT SEE CHART (J9)
MATES WITH MOLEX #22-01-2025
MOLEX 70553 SERIES RIGHT ANGLE HEADERLOW PROFILE, SQUARE PIN, .100 CENTERS
8 CIRCUIT SEE CHART (J4)MATES WITH MOLEX 70066 SERIES G VERSION
CONNECTOR HOUSING 50-57-9408 OR EQUIVALENT
MOLEX .156” PITCH RIGHT ANGLEFRICTION LOCK HEADER, SQUARE PIN
3 CIRCUIT SEE CHART (J1)MATES WITH AMP TERMINAL HOUSING
770849-3 OR EQUIVALENT
3.338±.015(84.79±0.38)
3.65±.01(92.7±0.25) J1-1 Vin
J1-2 Vin Return (Gnd)J1-3 Analog Speed In
J4-1 Motor Phase AJ4-2 Motor Phase CJ4-3 Hall - (Gnd)J4-4 Hall 1J4-5 Hall 2J4-6 Hall 3J4-7 Hall + (+12V)J4-8 Motor Phase B
J9-1 Return (Gnd)J9-2 Tach Out
J3 J21 1
C17
J91
J1
J5
J6J4
11
1
Controller DataMotor/Blower Contoller
48132*
Maximum Continuous Current 5 A
Input Voltage Range 11-52 VDC
Controller PWM Frequency 25 kHz
Analog Speed Input 0-5 VDC
Electrical Hall Spacing 60° or 120°
Waveform 6-Step Trapezoidal
Current Limit Protection Yes
Rotation CW / CCW
*These part numbers are available through AMETEK Technical & Industrial Products distributors.
NOTES:• Temperature: Operating: 0°C to 50°C, Storage Air: -40°C to 85°C.• Speed Control: Electrical speed control is achieved by applying a 0 to 5 VDC signal on J1 Pin 3 with respect to J1 Pin 2. Mechanical speed control is achieved
by adjusting the potentiometer when J6 is in position 1 to 2.• Current Control: 5 Amp RMS maximum.
Caution should be taken. Misplacement of jumper setting will destroy the control.Jumper Settings: J2-Motor Sensor Spacing: 120° electrical spacing with jumper connected (default).
60° electrical spacing with jumper disconnected.
J3-Rotations: Clockwise rotation with jumper connected (default). Counter-clockwise rotation with jumper disconnected. Do not change while motor is running or damage will occur.
J5-Input Voltage: Position 1-2 for 16-52 VDC (default). Position 2-3 for 11-16 VDC.
J6-Speed Control: Position 1-2 for internal speed adjust, via on board potentiometer (default). Position 2-3 for analog speed input, via 0-5 VDC signal applied to J1 pins 2 and 3.
J9: F out provides a 0-12 VDC square wave to monitor speed
F out (Hz) = ( Motor RPM ) ( Motor) 120 Poles
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
CONT
ROLL
ERS
115
10 Amp BLDC Motor/Blower Controller
1
INCH(MM)
MAX.
1.70(43.2)
1.00(25.4)
MAX.1.00(25.4)
MAX..156±.010(4±0.25)2X
.53±.01(13.5±0.25)
2X
2.190±.015(4.83±0.38)2X
.190±.010(4.83±0.25)4X
3.25±.01(82.6±0.25)
MOLEX 6373 VERTICAL FRICTION LOCK HEADERSQUARE PIN, .100 CENTER,2 CIRCUIT SEE CHART (J9)
MATES WITH MOLEX #22-01-2025
MOLEX .156” PITCH RIGHT ANGLEFRICTION LOCK HEADER, SQUARE PIN
8 CIRCUIT SEE CHART (J4)MATES WITH AMP TERMINAL HOUSING
770849-8 OR EQUIVALENT
MOLEX .156” PITCH RIGHT ANGLEFRICTION LOCK HEADER, SQUARE PIN
3 CIRCUIT SEE CHART (J1)MATES WITH AMP TERMINAL HOUSING
770849-3 OR EQUIVALENT
3.338±.015(84.79±0.38)
3.65±.01(92.7±0.25)
J1-1 VinJ1-2 Vin Return (Gnd)J1-3 Analog Speed In
J4-1 Motor Phase CJ4-2 Motor Phase BJ4-3 Motor Phase AJ4-4 Hall - (Gnd)J4-5 Hall + (+12V)J4-6 Hall 1J4-7 Hall 2J4-8 Hall 3
J9-1 Return (Gnd)J9-2 Tach Out
J3 J21 1
C17
J91
J1
J5
J6
J4
11
1
Controller Data Motor/Blower Contoller48133*
Maximum Continuous Current 10 A
Input Voltage Range 11-52 VDC
Controller PWM Frequency 25 kHz
Analog Speed Input 0-5 VDC
Electrical Hall Spacing 60° or 120°
Waveform 6-Step Trapezoidal
Current Limit Protection Yes
Rotation CW / CCW
NOTES:• Temperature: Operating: 0°C to 50°C, Storage Air: -40°C to 85°C.• Speed Control: Electrical speed control is achieved by applying a 0 to 5 VDC signal on J1 Pin 3 with respect to J1 Pin 2. Mechanical speed control is
achieved by adjusting the potentiometer when J6 is in position 1 to 2.• Current Control: Trip point is at 10 Amp maximum.
*These part numbers are available through AMETEK Technical & Industrial Products distributors.
Caution should be taken. Misplacement of jumper setting will destroy the control.Jumper Settings: J2-Motor Sensor Spacing: 120° electrical spacing with jumper connected (default).
60° electrical spacing with jumper disconnected.
J3-Rotations: Clockwise rotation with jumper connected (default). Counter-clockwise rotation with jumper disconnected. Do not change while motor is running or damage will occur.
J5-Input Voltage: Position 1-2 for 16-52 VDC (default). Position 2-3 for 11-16 VDC.
J6-Speed Control: Position 1-2 for internal speed adjust, via on board potentiometer (default). Position 2-3 for analog speed input, via 0-5 VDC signal applied to J1 pins 2 and 3.
J9: F out provides a 0-12 VDC square wave to monitor speed
F out (Hz) = ( Motor RPM ) ( Motor) 120 Poles
116
20 Amp BLDC Motor/Blower Controller
1.70(43.2) MAX.
1.56±.010(4±0.25)
3.25±.01(82.6±0.25)
3.338±.015(84.79±0.38)
3.65±.01(92.7±0.25)
2X
2.190±.015(4.83±0.38)2X
.190±.010(4.83±0.26)4X
.53±.01(13.5±0.25)2X
1.12(28.5) MAX.
1.40(35.6) MAX.
PIN 12 PIN 6
PIN 1
PIN 1
TERMINAL BLOCK.197 CENTERS#12 - #30 AWGSEE CHART (J1)
MOLEX 8724 SERIES DUAL ROW SHROUDED HEADERSQUARE PIN, .100 CENTERS, 12 CIRCUIT SEE CHART (J4)MATES WITH MOLEX 70450 SERIES DUAL ROW CRIMPCONNECTOR HOUSING NO. 22-56-6127 OR EQUIVALENT J4-1 Ground
J4-2 Hall 1J4-3 Hall 2J4-4 Hall 3J4-5 Hall +J4-6 BrakeJ4-7 GroundJ4-8 VrefJ4-9 Output EnableJ4-10 Forward/ReverseJ4-11 Tach OutJ4-12 Analog In
J1-1 VinJ1-2 Phase AJ1-3 Phase BJ1-4 Phase CJ1-5 Ground
INCH(MM)
PIN 7
J4
J1
C17
J2J3J6J5
1
1111
1
Controller Data Motor/Blower Contoller48134*
Maximum Continuous Current 20 A
Input Voltage Range 11-28 VDC
Controller PWM Frequency 25 kHz
Analog Speed Input 0-5 VDC
Electrical Hall Spacing 60° or 120°
Waveform 6-Step Trapezoidal
Current Limit Protection Yes
Rotation CW / CCW
*These part numbers are available through AMETEK Technical & Industrial Products distributors.
NOTES:• Temperature: Operating: 0°C to 50°C, Storage Air: -40°C to 85°C.• Speed Control: Electrical speed control is achieved by applying a 0 to 5 VDC signal on J4 Pin 12 with respect to J4 Pin 7. Mechanical speed control is
achieved by adjusting the potentiometer when J6 is in position 1 to 2.• Current Control: Trip point is at 20 Amp maximum.
Caution should be taken. Misplacement of jumper setting will destroy the control.Jumper Settings: J2-Motor Sensor Spacing: 120° electrical spacing with jumper connected (default).
60° electrical spacing with jumper disconnected.
J3-Rotations: Clockwise rotation with jumper connected (default). Counter-clockwise rotation with jumper disconnected. Do not change while motor is running or damage will occur.
J5-Input Voltage: Position 1-2 for 16-52 VDC (default). Position 2-3 for 11-16 VDC.
J6-Speed Control: Position 1-2 for internal speed adjust, via on board potentiometer (default). Position 2-3 for analog speed input, via 0-5 VDC signal applied to J1 pins 2 and 3.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts typical performance under controlled laboratory conditions using AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi cation. The above characteristics represent standard products. For product designed to meet specifi c applications, contact AMETEK Technical & Industrial Products Marketing and Sales.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
CONT
ROLL
ERS
117
20 Amp Programmable Motor/Blower Controllerwith Digital Signal Processor (DSP)
.156±.010(4±0.25)
3.65±.01(92.7±0.25)
2.00(50.8)MAX.
1.48(37.6)MAX.
1.12(28.5)MAX.
J5J5
J4
J2S1
J1
J4
PIN 1
C35
C34
POT1
OFF ON
PIN 6 PIN 12
PIN 7
3.338±.015(84.79±0.38)
TERMINAL BLOCK
.197 CENTERS#12 - #30 AWGSEE CHART J5
MOXLE #90130-3112 DUAL ROW SHROUDED HEADERSQUARE PIN, .100 CENTERS, 12 CIRCUIT SEE CHART (J4)
MATES WITH MOLES #90142-0012 DUAL ROW CRIMPCONNECTOR HOUSING WITH #90119-2109 SOCKET TERMINALS
2X
INCH(MM)
2.190±.015(55.63±0.38)2X
.53±.01(13.5±0.25)2X
.190±.010(4.83±0.25)4X
3.25±.01(82.6±0.25)
1
14
1
1
Controller Data Motor/Blower Contoller48140*
Maximum Continuous Current 20 A
Input Voltage Range 11-52 VDC (optional 60 VDC)
Controller PWM Frequency 20 kHz
Analog Speed Input 0-5 VDC, 2k-20k Potentiometer
Electrical Hall Spacing 60° or 120°
Waveform 6-Step Trapezoidal
Current Limit Protection Yes
Rotation CW / CCW
FEATURES:• Input Voltage Range: 11 to
52 VDC (Optional 60 VDC).
• Thermal Trip: 105°C or programmable.
• Braking: Connect J4-6 to Vin.
• Rotation: Direction can be changed during operation.
• Acceleration: Fast, slow, or programmable.
NOTES:• Temperature: Operating: 0°C to 50°C, Storage Air: -40°C to 85°C.
Switch Settings:S1.1 Off - 60° Electrical (4 Pole)
On - 120° Electrical (8 Pole)
S1.2 Off - OE Active when pulled high On - OE Active when pulled low
S1.3 Off - External speed control On - Internal potentiometer speed control
S1.4 Off - Fast acceleration On - Slow acceleration
Jumper Settings:J2 1-2, 11-18 VDCJ2 2-3, 16-52 VDCJ4-1 GroundJ4-2 Hall 1J4-3 Hall 2J4-4 Hall 3J4-5 Hall +J4-6 BrakeJ4-7 GroundJ4-8 VrefJ4-9 Output EnableJ4-10 Forward/ReverseJ4-11 Tach OutJ4-12 Analog/In
J5-1 GroundJ5-2 Phase CJ5-3 Phase BJ5-4 Phase AJ5-5 Vin
*These part numbers are available through AMETEK Technical & Industrial Products distributors.
118
BLDC MOTOR/BLOWER CONTROLLER NUMBERS
Combustion/
NautilAir
Blowers
NautilairModel
Harness Part
Number
Option Card
Harness
150330, 150230
5-39044 N/A
150332, 150232
5-39044 5-39048
150331, 150231
5-39045 N/A
150340, 150240
5-39046 N/A
150342, 150242
5-39046 5-39048
150341, 150241
5-39047 N/A
CableLength
mm Inches
5-39059-1* 457.2±12.7 18.00±.50
5-39059-2 609.6±12.7 24.00±.50
5-39059-3 304.8±12.7 12.00±.50
5-39060* 457.2±12.7 18.00±.50
39685 145.0±3.0 5.71±.12
39685-1 292.1±3.0 11.50±.12
39685-2 241.3±3.0 9.50±.12
39685-3 304.8±12.7 12.00±.50
39685-4 457.2±12.7 18.00±.50
39685-5 609.6±12.7 24.00±.50
39773 368.3±12.7 14.50±.50
39773-1 304.8±12.7 12.00±.50
39773-2 457.2±12.7 18.00±.50
39773-3 609.6±12.7 24.00±.50
39817* 457.2±12.7 18.00±.50
39817-1 609.6±12.7 24.00±.50
39817-2 304.8±12.7 12.00±.50
39831* 457.2±12.7 18.00±.50
39851 152.4±12.7 6.00±.50
39851-1 304.8±12.7 12.00±.50
39851-2 457.2±12.7 18.00±.50
39851-3 609.6±12.7 24.00±.50
* Cable 39831 or 5-39060 transfers hall signals from the motor/blower to the controller. Cable 39817 or 5-39059-1 does the same, but also provides cabling for analog input, tach output, braking, forward/re-verse, enable/disable, and voltage reference of a nominal 6.25 VDC at a maximum of 10 milliamps.
WINDJAMMER Voltage and
Power RatingBlower Type Speed Control
MethodHarness Part
Number
48 VDC, 500 WattBy-Pass and Through-Flow
Mechanical (M) 5-39062
Electrical (E) 5-39063
72 VDC, 500 WattBy-Pass and Through-Flow
Mechanical (M) 5-39062
Electrical (E) 5-39063
120 VAC, 250 WattBy-Pass and Through-Flow
Mechanical (M) 39649
Electrical (E) 39650
240 VAC, 400 Watts
By-PassMechanical (M) 39679
Electrical (E) 39680
Through-FlowMechanical (M) 39679
Electrical (E) 39680
120 VAC, 800 Watt By-PassMechanical (M) 39795
Electrical (E) 39796
240 VAC, 1200 Watt By-PassMechanical (M) 39679
Electrical (E) 39680
Motor/Blower
Part Number
ControllerPart
Numbers
Mating Cable from External Controller to
Motor/Blower
InputPower
Cable to External
Controllerfor
Controller 48134for
Controller 48140
116450 48133 N/A N/A 39773
116521 48133 N/A N/A 39773
116522 48133 N/A N/A 39773
119272 48134 or 48140 N/A N/A N/A
119275 48134 or 48140 N/A N/A N/A
119000 48134 or 48140 39831 or 39817* 5-39060 or 5-39059-1* N/A
119001 48134 or 48140 39831 or 39817* 5-39060 or 5-39059-1* N/A
119002 48134 or 48140 39831 or 39817* 5-39060 or 5-39059-1* N/A
119003 48134 or 48140 39831 or 39817* 5-39060 or 5-39059-1* N/A
119004 48134 or 48140 39831 or 39817* 5-39060 or 5-39059-1* N/A
119005 48134 or 48140 39831 or 39817* 5-39060 or 5-39059-1* N/A
119006 48134 or 48140 39831 or 39817* 5-39060 or 5-39059-1* N/A
119007 48134 or 48140 39831 or 39817* 5-39060 or 5-39059-1* N/A
119008 48134 or 48140 39831 or 39817* 5-39060 or 5-39059-1* N/A
119050 48134 or 48140 39831 or 39817* 5-39060 or 5-39059-1* N/A
119051 48134 or 48140 39831 or 39817* 5-39060 or 5-39059-1* N/A
119052 48134 or 48140 39831 or 39817* 5-39060 or 5-39059-1* N/A
119053 48134 or 48140 39831 or 39817* 5-39060 or 5-39059-1* N/A
119054 48134 or 48140 39831 or 39817* 5-39060 or 5-39059-1* N/A
119055 48134 or 48140 39831 or 39817* 5-39060 or 5-39059-1* N/A
119056 48134 or 48140 39831 or 39817* 5-39060 or 5-39059-1* N/A
119057 48134 or 48140 39831 or 39817* 5-39060 or 5-39059-1* N/A
119058 48134 or 48140 39831 or 39817* 5-39060 or 5-39059-1* N/A
119375 48133 or 48140 39851 N/A 39773
119380 48133 or 48140 39851 N/A 39773
119383 48133 or 48140 39851 N/A 39773
119381 N/A N/A N/A 39773
119382 N/A N/A N/A 39773
119384 N/A N/A N/A 39773
119385 N/A N/A N/A 39773
119378 N/A N/A N/A 39773
119379 N/A N/A N/A 39773
150016 48132 39685 N/A 39773
150017 48132 39685 N/A 39773
150166 N/A N/A N/A 39773
150193 48140 N/A N/A N/A
119AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
ENGI
NEER
ING
NOTE
S
119
Blower SizingPurpose of product which blower is to be incorporated in __________________________________________________________________________________________________________________________
Describe general operation _______________________________________________________________________________________________________________________
Estimated annual requirements ____________________ ________________________________________________
Power Supply: _________VDC __________VAC
Air Flow Requirements: _______To __________ CFM(m3/hr)
Air Flow Requirements: _______To __________ In. H2O(mBar)
Standard Operating Point:Pressure or Vacuum _______ In. H2O, Flow______ CFM (mBar) (m3/hr)
Surrounding Temperature:Min. ________°F (°C) Max.________°F (°C)
Humidity: _____________________________________
Agency Requirements: ISO9001 UL TUV CSA Other
Expected Life Hours: ___________________________
Production Delivery Date: _______________________
Expected Price Range: _________________________
If ReplacementCurrent Manufacturer: __________________________
Model: _______________________________________
MOTOR/BLOWER SIZING FORM
PLEASE COMPLETE THIS FORM AND FAX IT TO +1 330-677-3306,ATTENTION: TECHNICAL & INDUSTRIAL PRODUCTS MARKETING DEPARTMENT
DATE ________________________________________
COMPANY ________________________________________________________________________________
ADDRESS _________________________________________________________________________________
CITY ___________________________STATE _______ ZIP ___________COUNTRY ___________________
NAME _____________________________________________________________________________________
TITLE ___________________________________DEPT. _________________________
TELEPHONE ______________________________FAX _________________________
E-MAIL ________________________________________________________________Complete applicable side for additional information.
Motor SizingPurpose of product which motor is to be incorporated in __________________________________________________________________________________________________________________________
Describe general operation _______________________________________________________________________________________________________________________
Estimated annual requirements ____________________ ________________________________________________
Power Supply: _________VDC __________VAC
Speed Requirements: _______To _________ RPM
Maximum Continuous Performace Requirement Speed ________ RPM Torque ________ Oz. In. (Ncm) Power ________ HP (watts)
Dimension, Max.:Diameter _____ In. (mm) Length _____ In. (mm)
Surrounding Temperature:Min. ________°F (°C) Max.________°F (°C)
Humidity: _____________________________________
Expected Life Hours: ___________________________
Production Delivery Date: _______________________
Expected Price Range: _________________________
If ReplacementCurrent Manufacturer: __________________________
Model: _______________________________________
Throughout our catalog, you will fi nd terminology used for air moving selection and product sizing. Below are a few of the key terms:
Flow (Volume Rate/Time)• AMETEK charts are in SCFM, m3/min, or L/S• SCFM = Standard Cubic Feet Per Minute
(American)• M3/min = Cubic Meters Per Minute (Metric)• L/sec = Liters Per Second (Metric)
Pressure (Force/Area)• AMETEK charts are in In. H2O (IWG), PSIG, mm
of Water, IHG, or mbar• IWG = Inches of Water Gauge (American)• PSIG = Pounds Per Square Inch Gauge (American)• mm of Water = Millimeter of Water Gauge (Metric)• IHG = Inches of Mercury Gauge (American)• mbar = Millibar Gauge (Metric)• PSIA = Pounds Per Square Inch Absolute
(American)• Standard Atmosphere = 0 PSIG = 14.7 PSIA
Density (Weight/Volume)• Standard Air = 0.075 lb./cubic foot
Specifi c Gravity (Density Ratio Relative to Air)• Standard Air SG = 1.0• Methane SG = 0.55
Velocity (Distance/Time or Flow/Area)• FPM = Feet Per Minute (American)• M/min = Meters Per Minute (Metric)
Pressure Drop/Back Pressure/Impedance
• Friction causes air to slow down and lost energy is measured in pressure drop terms
• Typical pressure drop areas include piping, elbows, accessories, and system
• Each fi xed system has a fi xed system impedance caused by a single or multiple pressure drop points
• Changing the system impedance will cause the blower’s work point to change
engineering BASICS – Air moving
120
121AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
ENGI
NEER
ING
NOTE
S
121
ALT
ITU
DE
-FE
ET
BA
RO
ME
TR
IC P
RE
SS
UR
E
Inch
Hg
(32°
)F
lbs./ft3
Density
°C °F
PS
IA
EQUATION:
STANDARD AIR
p = 1.325 x Pa
459.7 + T
where,
p = Density, lbs./ft3
Ps = Barometric Pressure, Inches Hg
T = Ambient Temperature °F
35
32.5
30
27.5
25
22.5
20
17.5
15
10
7.5
5
2.5
0
17
16.5
16
15.5
15
14.5
14
13.5
13
12.5
12
11.5
11
10.5
10
9.5
9
8.5
8
7.5
7
6.5
6
5.5
5
4.5
4
3.5
3
2.5
2
-100
-90
-80
-70
-60
-50
-40
-30
-20
-10
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
-150
-125
-100
-75
-50
-25
0
25
50
75
100
125
150
175
200
225
250
275
300
325
350
375
400
.1600
.1550.1500
.1450.1400
.1350.1300
.1250.1200
.1150.1100
.1050.1000
.0950
.0900
.0850
.0800
.0700
.0600
.0500
.0400
.0350
.0300
.0250
.0200
.0175
.0150
.0125
.0100
.0075
.0050
.0025
0
0
1,000
2,000
3,000
4,000
5,000
6,000
7,000
8,000
9,000
10,000
11,000
12,000
13,000
14,000
15,000
20,000
25,000
30,000
35,000
40,000
45,000
50,000
55,000
60,000
70,000
density correction chart
In the following formulae these symbols are used:
P – Pressure in pounds per square inch (PSI) or inches of mercury column (inches Hg)
CFM – Volume in cubic feet per minute
RPM – Speed in revolutions per minute
D – Density in pounds per cubic foot (lbs./cu. ft.)
H – Height of air or gas column (ft.)
SG – Specifi c Gravity (ratio of density of gas to the density of air)
“Standard Air”-Air at 68°F (absolute temperature 528°) and 29.92” Hg. (barometric pressure at sea level). The density of such air is 0.075 lbs./cu. ft. and the specifi c volume is 13.29 cu. ft./lb. The specifi c gravity is 1.0.
The outlet pressure of a blower depends on the condition of the air or gas at the inlet. The inlet condition is infl uenced by:
a – Specifi c gravity (the ratio of density of the gas to density of standard air) b – Altitude (location of blower) c – Temperature of inlet air
Basic Fan Laws ChartVARIABLE VOLUME PRESSURE HORSEPOWER
WHEN SPEED CHANGES
Varies DIRECT with Speed Ratio
CFM2 = CFM1 ( RPM2 ) RPM1
Varies with SQUARE of Speed Ratio
P2 = P1 ( RPM2 )2
RPM1
Varies with CUBE of Speed Ratio
HP2 = HP1 ( RPM2 )3
RPM1
WHEN DENSITY CHANGES Does Not Change
Varies DIRECT with Density Ratio
P2 = P1 ( D2 ) D1
Varies DIRECT with Density Ratio
HP2 = HP1 ( D2 ) D1
VolumeThe volume changes in direct ratio to the speed.Example – A blower is operating at 3500 RPM and deliver-ing 1000 CFM. If the speed is reduced to 3000 RPM, what is the new volume?
V1 = Original Volume (1000 CFM)
V2 = New Volume
RPM1 = Original Speed (3500 RPM)
RPM2 = New Speed (3000 RPM)
V2 = V1 ( RPM2 )1 = 1000 x ( 3000 )1
= 1000 x .857 = 857 CFM RPM1 3500
PressurePressure (barometric) varies in direct proportion to altitude.Example – A blower is to operate at an elevation of 6000 feet and is to deliver 3 PSI pressure. What pressure (standard air) blower is required?
Pressure = 3 x 29.92 = 3.75 or 3 3/4 PSI23.98
If it is desired to determine what pressure a 3 PSI (standard air) blower will deliver at 6000 feet –
Pressure = 3 x 23.98 = 2.4 or about 2 1/2 PSI29.92
When a blower is to operate at a high altitude it is frequently specifi ed that the blower be capable of handling a given volume of “standard air”. It is then necessary to determine the equivalent volume of air at the higher altitude.
Example – A blower is to operate 6000 feet altitude and is to handle 1000 CFM of standard air. What is the CFM of air the blower must handle at 6000 feet altitude?
Let: V1 = Volume of standard air (1000 CFM)
V2 = Volume of thinner air
Hg1 = Barometric pressure sea level (29.92)
Hg2 = Barometric pressure 6000 ft. (23.98)
V2 = V1 x Hg1 = 1000 x 29.92 = 1248 CFM
Hg2
23.98
The pressure changes as the square of the speed ratio.Example – A blower is operating at a speed of 3500 RPM and delivering air at 5.0 PSI pressure. If the speed is reduced to 3000 RPM, what is the new pressure?
P1 = Original Pressure (5 PSI)
P2 = New Pressure
RPM1 = Original Speed (3500 RPM)
RPM2 = New Speed (3000 RPM)
P2 = P1 ( RPM2 )2 = 5 x ( 3000 )2
= 5 x .735 = 3.68 PSI RPM1 3500
physical laws for blower applications
122
123AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
ENGI
NEER
ING
NOTE
S
123
Air DensityThe Air Density varies in inverse proportion to the absolute temperature.Example – A blower is to handle 200°F air at 3 PSI pressure. What pressure (standard air) blower is required?
Let: P1 = Pressure hot air (3 PSI)
P2 = Pressure standard air
AT1 = Absolute temperature hot air (200+460=660°F)
AT2 = Absolute temperature standard air (68+460=528°F)
P2 = P1 x AT1 = 3 x 660 = 3.75 or 3 3/4 PSI
AT2
528
A blower is capable of delivering 3 PSI pressure with standard air. What pressure will it develop handling 200°F inlet air?
P1 = P2 x AT2 = 3 x 528 = 2.4 or 2 1/2 PSI
AT1
660
Pressure varies in direct proportion to the density.Example – A 3 PSI (standard air) blower is to be used to handle gas having a specifi c gravity of 0.5. What pressure does the blower create when handling the gas?
Let: Pa = Air pressure (3 PSI)
Pg = Gas pressure
SG = Specifi c gravity of gas (0.5)
Pg = Pa x SG = 3 x .5 = 1.5 PSI
If we are required to handle a gas having a specifi c gravity of 0.5 at 1.5 PSI pressure, we can determine the standard air pressure blower as follows:
Let: Pa = Pg = 1.5 = 3 PSI
SG
.5
HorsepowerThe horsepower changes as the cube of the speed ratio.Example – A blower is operating at a speed of 3500 RPM and requiring 50 horsepower. If the speed is reduced to 3000 RPM, what is the new required horsepower?
HP1 = Original Horsepower (50)HP2 = New HorsepowerRPM1 = Original Speed (3500 RPM)RPM2 = New Speed (3000 RPM)
Horsepower vs. Specific Gravity and Ratio of Density.The horsepower varies in direct proportion to the specifi c gravity (ratio of density of gas to density of air).
Example – A standard air blower requires a 10 HP motor. What horsepower is required when this blower is to handle a gas whose specifi c gravity is 0.5?
HP = 10 x 0.5 = 5 horsepower
HP2 = HP1 x ( RPM2 )3 = 50 x ( 3000 )3
= 50 x .630 = 31.5 horsepower RPM1 3500
It is possible that several of the above modifi cations may be required on one installation. Therefore, it may be necessary to use various combinations of these formulae.
Blower Application Law Examples
engineering BASICS
engineering BASICS – motion
engineering BASICS – pump
Throughout our catalog, you will fi nd terminology used for motor selection and product sizing. Below are a few of the key terms:
Horsepower, Torque, and SpeedThe basic relationship between horsepower, torque, and
speed.HP = (RPM x torque) / 63029 lb.-in.Torque (XXX) = (Horsepower x 63029)/RPMHP = HorsepowerT = Torque (lb.-in.)N = Speed in RPM
Motor Contant Motor Constant (Km) = Peak torque / Peak power at stallMotor power to torque ratioKm = KT / RT
AT = Peak torque, oz.-in. / AmpRT = Motor terminal resistance, Ohms
Electrical Time Constant = Inductance / Resistance
Equal to L/RMeasured in secondsEqual to the time it takes the current to reach 63% of the
steady state, for a fi xed voltageL = Inductance, HR = Resistance, Ohms
Mechanical Time Constant = (Rotor Inertia x Resistance) / (Motor Torque Constant x Motor Back EMF)
Equal to time required for the motor’s speed to attain 63.2% of its fi nal value, for a fi xed voltage.
Measured in seconds(J * R) / (Kt * Ke)J is the rotor inertia, Kg-m2
R is the resistance, OhmsKt is the motor torque constant, v / rad / sKe is the motor back-EMF constant, Ncm / Amp
Back EMF Constant (Ke) = Volts / K RPMThe generated voltage as a function of rotor speed.
Torque Constant (Kt) = oz.-in. / AmpThe torque produced for a given input current.
* Q = 449 x V x AQ = Capacity, GPMV = Velocity of fl ow, ft./sec.A = Area of pipe, ft.2
* Head (ft.) = Pressure (psi) * 2.31 Specifi c Gravity
* WHP = Q * HT * SP GR
3960Q = GPMHT = Total differential head, ft.SpGr = Specifi c gravity of fl uidWHP = Water horsepower
124
125AMETEK TECHNICAL & INDUSTRIAL PRODUCTS627 Lake Street, Kent OH 44240Tel: +1 330-673-3452 • Fax: +1 330-677-3306 • www.ametektip.com
ENGI
NEER
ING
NOTE
S
125
STANDARD ENGINEERING CONVERSIONS
MULTIPLY BY TO OBTAINAtmospheres 76.0 Cms. of MercuryAtmospheres 29.92 Inches of MercuryAtmospheres 406.8348 Inches of WaterAtmospheres 10,333 Kgs./Sq. MeterAtmospheres 1.013 x 105 PascalsAtmospheres 14.70 Pounds/Sq. InchAtmospheres 760 Torrs
Bars 0.9869 AtmospheresBars 1. x 105 Dynes/Sq. Cm.Bars 1.020 x 104 Kgs./Square MeterBars 14.50 Pounds/Sq. InchBritish Thermal Units 0.2520 Kilogram-CaloriesBritish Thermal Units 777.5 Foot-PoundsBritish Thermal Units 1054 JoulesBritish Thermal Units 107.5 Kilogram-MetersBritish Thermal Units 2.928 x 10–4 Kilogram-HoursBritish Thermal Units/Hour 0.293 Watts
Centimeters of Mercury 0.01316 AtmospheresCentimeters of Mercury 0.0372 Inches of WaterCentimeters of Mercury 136.0 Kgs./Square MeterCentimeters of Mercury 0.1934 Pounds/Sq. InchCentimeters/Second 1.969 Feet/MinuteCentimeters/Second 0.6 Meters/MinuteCubic Centimeters 3.531 x 10–5 Cubic FeetCubic Centimeters 6.102 x 10–2 Cubic InchesCubic Centimeters 10-6 Cubic MetersCubic Centimeters 10-3 LitersCubic Feet 2.832 x 104 Cubic Cms.Cubic Feet 1728 Cubic InchesCubic Feet 0.02832 Cubic MetersCubic Feet 0.03704 Cubic YardsCubic Feet 28.32 LitersCubic Feet/Minute 472.0 Cubic Cms./Sec.Cubic Feet/Minute 1.6992 Cubic Meters/HourCubic Feet/Minute .02832 Cubic Meters/MinuteCubic Feet/Minute 28.32 Liters/MinuteCubic Feet/Minute 0.4720 Liters/SecondCubic Feet/Minute 62.4 Lbs. of Water/Min.Cubic Inches 16.39 Cubic CentimetersCubic Inches 5.787 x 10–4 Cubic FeetCubic Inches 1.639 x 10–5 Cubic MetersCubic Meters 105 Cubic CentimetersCubic Meters 35.31 Cubic FeetCubic Meters 61,023 Cubic InchesCubic Meters/Hour .5885 Cubic Feet/MinuteCubic Meters/Minute 35.3107 Cubic Feet/Minute
Feet 30.48 CentimetersFeet 12 InchesFeet 0.3048 MetersFeet 1/3 YardsFeet of Air (1 atmosphere 60°F) 5.30 x 10–4 Pounds/Square Inch
Gallons 3.785 LitersGallons/Minute 0.0631 Liters/SecondGrams/Cu. Cm. 62.43 Pounds/Cubic Foot
Horsepower 42.44 British Thermal Units/Min.Horsepower 33,000 Foot-Pounds/Min.Horsepower 10.70 Kg. Calories/Min.Horsepower 745.7 WattsHorsepower-Hours 2547 British Thermal Units
Inches 2.540 CentimetersInches 103 MilsInches of Mercury 0.03342 AtmospheresInches of Mercury 13.60 Inches of WaterInches of Mercury 345.3 Kgs./Square MeterInches of Mercury 25.40 Mms. of MercuryInches of Mercury 0.4912 Pounds/Square In.Inches of Water 0.002458 AtmospheresInches of Water 0.07355 Inches of MercuryInches of Water 25.40 Kgs./Square MeterInches of Water 2.4884 MillibarsInches of Water 248.8 PascalsInches of Water 5.204 Pounds/Square Ft.Inches of Water 0.03613 Pounds/Square In.
MULTIPLY BY TO OBTAINKgs./Cubic Meter 0.06243 Pounds/Cubic FootKilometers 3281 FeetKilowatts 56.92 British Thermal Units/Min.Kilowatts 737.6 Foot-Pounds/Sec.Kilowatts 1.341 HorsepowerKilowatts 14.34 Kg.-Calories/Min.Kilowatt-Hours 3415 British Thermal Units
Liters 103 Cubic CentimetersLiters 61.02 Cubic InchesLiters 10–3 Cubic MetersLiters .2642 GallonsLiters/Minute .0353 Cubic Feet/MinuteLiters/Second 2.119 Cubic Feet/MinuteLog10N 2.303 LogEN or Ln NLog N or Ln N 0.4343 Log10N
Meters 100 CentimetersMeters 3.2808 FeetMeters 39.37 InchesMeters 10–3 KilometersMeters 103 MillimetersMiles 5280 FeetMiles 1.6093 KilometersMiles 1760 YardsMillibars .4019 Inches of WaterMms. of Mercury 0.0394 Inches of MercuryMms. of Mercury 1.3595–3 Kgs./Square Cm.Mms. of Mercury 0.01934 Pounds/Square Inch
Newton Meters .7376 Pound-Force-FootNewton Meters 141.643 Ounce-Force-Inch
Ounce - Force - Inch 0.706 Newton - CentimeterOunce - Force - Inch 7.06 x 10–3 Newton - MeterOunce - Force - Inch 5.21 x 10–3 Pound - Force - Foot
Pascals .004 Inches of WaterPints (Liq.) 28.87 Cubic InchesPints (U.S. liquid) 473,179 Cubic CentimetersPints (U.S. liquid) 16 Ounces (U.S. fl uid)Pounds 444,823 DynesPounds 453.6 GramsPounds 16 OuncesPounds of Carbon to CO2 14,544 British Thermal Units (mean)Pounds of Water 27.68 Cubic InchesPounds of Water 0.1198 GallonsPounds of Water Evaporated at 212°F 970.3 British Thermal UnitsPounds/Cubic Foot 16.02 Kgs./Cubic MeterPounds/Cubic Foot 4.882 Kgs./Square MeterPounds-Force-Foot 1.3558 Newton MetersPounds/Square Inch 0.06804 AtmospheresPounds/Square Inch 27.7 Inches of WaterPounds/Square Inch 2.036 Inches of MercuryPounds/Square Inch 703.1 Kgs./Square MeterPounds/Square Inch 6.895 x 103 PascalsPounds/Square Inch 51.715 Millimeters of Mercury at 0°C
Rad/Second 9.551 Revolutions/MinutesRevolutions/Minutes .1047 Rad/Second
Square Centimeters 1.973 x 105 Circular MilsSquare Centimeters 1.076 x 10–3 Square FeetSquare Centimeters 0.1550 Square InchesSquare Feet 929.0 Square CentimetersSquare Feet 0.09290 Square MetersSquare Inches 1.273 x 106 Circular MilsSquare Inches 6.452 Square CentimetersSquare Inches 6.944 x 10–3 Square FeetSquare Inches 106 Square MilsSquare Inches 645.2 Square MillimetersSquare Kilometers 10.76 x 106 Square FeetSquare Kilometers 1.196 x 106 Square YardsSquare Meters 10.764 Square FeetSquare Meters 1.196 Square Yards
Temp. (°C) +273 1 Abs. Temp. (°C)Temp. (°C) +17.8 1.8 Temp. (°F)Temp. (°F) +460 1 Abs. Temp. (°F)Temp. (°F) -32 5/9 Temp. (°C)
Watts 0.05692 British Thermal Units/Min.Watts 107 Ergs/SecondWatts 44.26 Foot-Pounds/Min.Watts 1.341 x 10–3 HorsepowerWatts 0.01434 Kg.-Calories/Min.Watts-Hours 3.415 British Thermal UnitsWatts-Hours 1.341 x 10–3 Horsepower/Hours