PROCESS SENSORS pH Oxygen Conductivity

Transcript of Process Sensors Hamilton

Page 1: Process Sensors Hamilton

PROCESS SENSORS

pH – Oxygen – Conductivity

Page 2: Process Sensors Hamilton

– 2 –

Product Overview

To order products from this catalog, pleasecontact your HAMILTON process sensor distributor or HAMILTON company for the distributor in your area.

Other product lines made by HAMILTON:

- pH Electrodes for Laboratory and Portable Use- Customized Sensors and Accessories- Syringes- SoftGrip™ Pipettes- Diluters/Dispensers- Valves- OEM Components- Pipetting Robots- Automated Analyzers- HPLC Columns and bulk resin

Page 3: Process Sensors Hamilton

– 3 –

Product Overview Contents

Innovation in Electrochemistry 4

HAMILTON‘s pHeasy® Technology 7

Conductivity standards 8

DURACAL buffer solutions 10

pH and Redox Sensor Applications 12 pH-PathfinderTM for pharmaceutical 12 Pharmaceutical industry and fermentation 13 Sugar industry, food and beverages 15 Low conductivity, ion-weak media 16 Chemical industry, oxides 18 Paper industry 21 Swimming pools, sea and waste water, etc. 22

Standard armatures 33 Pressurizable armatures 35 Retractable armatures 36 Armature accessories 40

Armatures 42 Oxygen sensors 43 pH sensors 44 Alphabetical 46 Numerical 47

pH-Simulator 25

Oxygen Sensors 26

Conductivity and 6-in-1 Sensors 30

Connecting Cables for Sensors 32

Armatures 33

Technical Data 42

Index 46

Page 4: Process Sensors Hamilton

– 4 –

0

10

20

30

40

50

60

70

80

90

100

0 10 20 30 40 50 60 70 80 90 100

Drift

[mV]

POLISOLVE PLUS

Innovation in Electrochemistry

HAMILTON manufactures more than pH sensors. Our electrochemical sensors are reliable tools for application-oriented use and are characterized by the highest quality, long life and competitive price. In order to meet these rigorous requirements we are constantly striving to find new ways to design our sensors. As a result of the extensive work by our research and development department, HAMILTON and only HAMILTON is able to offer the following detailed solutions:

The SINGLE PORE concept:Precise, reliable, fast readings with a

“never clog” liquid junction

The POLISOLVE electrolyte:Most innovative polymer reference

electrolyte

The EVEREF reference system:Long electrode life thanks to stable

reference potentials

It used to be that pH electrodes with a polymer electrolyte could not be used over the entire pH or temperature range. HAMILTON has designed the innovative POLISOLVE polymer electrolyte sensors that cover a pH range from 0 to 14 and temperatures from -10°C to 130°C. As an added benefit the POLISOLVE polymer is also stable to most organic solvents and free of toxic acrylamide.When you combine the POLISOLVE with the SINGLE PORE concept you have the solution to pH measurement in a wide application range including:• Industrial waste water

• Hot sugar juice

• Samples containing color pigments

• Oily samples

• Fermentation process

With the POLISOLVE PLUS electrolyte, HAMILTON has achieved an important new development that means even more stable reference signals. Thanks to an ingenious built-in filter system, reference poisons remain harmless for a lot longer. At the same time, troublesome diffusion potentials are minimized. POLISOLVE PLUS represents a significant contribution to long lasting pH sensors.

Stable reference systems are at the heart of reliable, long-life electrodes. This is why many Hamilton electrodes are equipped with reference systems from the EVEREF family. The silver chloride reservoir is separated from the reference electrolyte by a diffusion distance which prevents the loss of silver chloride due to temperature variations, and allows the use of silver-free electrolytes. The EVEREF-L labyrinth system used in the POLILYTE electrodes further extends the diffusion distance to almost 200 mm, greatly increasing electrode life in aggressive media. The EVEREF-F system contains a silver barrier which prolongs electrode life in aggressive samples.

Since its introduction in 1991, the SINGLE PORE concept has been increasingly successful. The advantage of this solution is clear: instead of many tiny pores in a ceramic diaphragm, a single pore about 2000 times larger (in the form of a glass capillary) is used. This SINGLE PORE is practically impossible to clog. In combination with a special electrolyte, the flow rate through the pore is faster and provides much better contact between the reference electrode and sample. This allows faster response time and more accurate readings.

Note: The PTB (Physikalisch-Technische-Bundes-anstalt = Physical Technical Federal Institute) in Braunschweig, Germany determined the SINGLE PORE pH electrode to be the most accurate laboratory electrode. Further information can be found in "Traceability of pH measurement" by Petra Spitzer; ISBN 3-89429-877-4 or ISSN 0947-7063

runtime [days]

Competitor 4250

The POLISOLVE PLUS Electrolyte:Drift while aging the sensors in 80°C hot deionized water.

Page 5: Process Sensors Hamilton

– 5 –

Innovation in Electrochemistry

HAMILTON pH glasses:Guarantee the accuracy of your

measurements

The TK inner buffer:Ion-weak samples are no longer a

problem

The oxygen sensor OxyGold B:Dissolved oxygen measurement with

absolutely no interference from CO2

Ion-weak samples have always been a problem for electrochemical electrodes. This has been solved by the development of the TK inner buffer, used for the first time in the LIQ-GLASS PG and IONOTRODE electrodes. Using a special membrane shape, a low membrane resistance and easy pH measurement in ion-weak samples is guaranteed. For maintenance-free measurement of ion-weak samples try POLILYTE PRO or even better POLILYTE HT or pHeasy sensors.

Continuous improvement to our pH glass provides benefits that have not been previously available. A high performance glass called PHI glass is the result of research at HAMILTON. This membrane material was developed to withstand frequent steam sterilization, autoclavation and CIP cleaning using hot caustics. It provides the lowest drift and shows almost no shift after sterilization. The HAMILTON H glass has excellent aging characteristics and offers stable readings even in samples with a low water content such as anhydrous or only partially aqueous solutions. The low alkali error of H glass means accurate measurements even at high pH or high operating temperatures.An HF glass is the latest development to ensure longest possible lifetime in processes containing hydrofluoric acid.Most electrodes for low-temperature applications have a membrane made of V glass. This unique development has been able to dramatically reduce membrane resistance still further. It is now possible to form mechanically stable membranes that are significantly

less sensitive to aging effects.

Dissolved oxygen is an important parameter used to control the shelf life of beverages, especially beer, sweet soda drinks and fruit juice. The traditional technology used to measure oxygen in these applications has been sensors based on an amperometric, membrane-covered Clark cell filled with alkaline electrolyte. The gases from the sample diffuse through the membrane and give the measurement signal when reacting in the sensor. Guess what happens when the chemistry in the sensor is changing? The measurement performance will change and so will the signal. This is systematically the case when acidic gases like carbon dioxide are present. They change the pH of the originally alkaline electrolyte in the Clark cell. The results are drifting and uncertain measurements! HAMILTON invested a couple of years in the development of the unique OXYGOLD B sensors that are filled with a CO2-stable acidic electrolyte called OXYLYTE B. The unique performance of this dissolved oxygen sensor has made it an acknowledged reliable measuring tool for breweries around the world!

Page 6: Process Sensors Hamilton

– 6 –

Innovation in Electrochemistry

A complete range of patented pH buffer solutions provides never before achieved pH stability. HAMILTON guarantees DURACAL pH buffers to last for five years from the date of manufacture. The pH 9.21 and pH 10.01 buffers are even stable in air. High buffer capacities enable quick and stable calibrations. Closed-loop traceability: in contrast with other manufacturers who operate with a hierarchical (top-down) traceability, HAMILTON has developed a new approach featuring “closed-loop” traceability. For users of DURACAL pH buffer solutions this means a unique level of reliability.Top-down traceability: with Hamilton the pH value of the DURACAL buffer is determined by a comparison with two secondary reference solutions. Bottom-up traceability: from each lot manufactured, a representative quantity is measured at DKD. This ensures an external independent verification by an accredited institute. The DKD issues an official calibration certificate for every DURACAL batch manufactured.

Stable reference systems are the heart of reliably functioning, long-lasting electrodes. In pH measurement up till now, the user was not spared the need for frequent calibration. The reason for this lies in shifting reference potentials due to chloride loss in the reference electrolyte. However, contaminated and partially clogged diaphragms also contribute considerably to changing properties in pH electrodes, which can only be resolved with a fresh calibration. For pH measurements where a very high degree of accuracy is required, it should therefore be sufficient if the pH-sensor is calibrated just before measuring. But in industrial applications - especially in the case of online pH measurement - this is possible only with a great deal of effort, if at all. What is even worse: even if a calibration with certified pH buffers is correctly carried out, the very next measurement will not necessarily be accurate! Depending on the age of the electrode or, more precisely, the state of the diaphragm and the chloride content in the reference electrolyte, different diffusion potentials may occur in buffers and measurement medium. Technically speaking, it is possible to eliminate this source of error entirely, but with patented pHeasy technology it is possible for the first time to detect it online!Hamilton, with its pH glasses and the ingenious inner buffer, has built true long term stability into pHeasy electrodes.

HAMILTON is the first seller worldwide of conductivity standards at 1.3 and 5 µS/cm with a certified accuracy of ±1 % and a durability of 1.5 or 3 years. The composition of these standards is patented. The measurement procedure for determining conductivity has been developed in collaboration with DFM. State metrological institutes that deal with measurement of electrolytic conductivity have become aware of these HAMILTON standards, since they lie in a low conductivity range and exhibit a previously unknown level of stability which has been confirmed by measurements done by PTB. In an interlaboratory test among prestigious European metrological institutes (PTB, DFM, DKD), HAMILTON standards were used as a measurement solution.

Conductivity Standards:Certified from an accredited laboratory.

Fulfills USP chapter 625 requirements

Duracal pH Buffers:Certified from an accredited laboratory.

5 -year stability and easy handling

pHeasy-Technology:Ensures accurate measurements without

recalibration and predicts loss of

measurement accuracy

Page 7: Process Sensors Hamilton

– 7 –

HAMILTON’s pHeasy Technology

• pH measurements made simple• truly maintenance-free• Recalibration is no longer needed• measure pH calibration-free, and at the

same time monitor measurement accuracy on a continuous basis

• Advance warning when it‘s time to replace the electrode

• Carry out preventive maintenance in such a way as to optimize time and money

• Notifi cation of shift in the reference potential

• Warning of diffusion potentials likely to cause incorrect measurement values

• No diaphragms thanks to Hamilton’s SINGLE PORE® technology and POLISOLVE™ reference electrolytes

• Compatible with commercially available pH measuring devices with an extra redox input

• Less uncertainty in calibration • Built-in option for monitoring accuracy • Improved reliability of measurement• No diaphragm – so no diaphragm

problems • Fewer handling errors – greater user

safety

pH measurements with pHeasy ®

offer many advantagesNever Recalibrate

With pHeasy ® only one calibration at the start of operation is needed

• Every measurement solution produces a certain diffusion potential across the reference system. The error arising from this is small, as long as the reference system still has a high chloride concentration.

• Over time the electrode loses chloride, and the measurement error increases during the measurement depending on the medium. Needless to say, this error is undetectable in the pH buffer solutions due to the buffer composition, and is not removed during calibration. The result is a inaccurate measurement.

• That is why old electrodes are less accurate. pHeasy ® monitors these hidden inaccuracies!

Recognize hidden inaccuracies

pHeasy ® technology consists of these hardware components: clog-free SINGLE PORE hole diaphragm, patented POLISOLVE electrolyte, extremely stable reference outlet, and CheckRef outlet. The difference in potential between REF and CheckRef to be measured with a Redox or pH inlet reveals the uncertainty of the measurement. Through limit contacts, warnings and alarms (for example at 30 and 50 mV) can be triggered.

• The measuring device can provide notification of needed replacement of the electrode

• The Checkref provides early detection and monitoring of reference poisons. This is because the pHeasy Checkref is positioned closer to the junction than the sensor reference.

• Interfering diffusion potentials can be monitored in-situ using pHeasy.

pHeasy ® - patent pending

pHeasy ® • pH 0 - 14 • Temperature range: • Pressure range:0 - 6 bar 0 - 60°C (pHeasy);• Certificate 0 -130°C (pHeasy HT)• Serial number • Pt 1000

Electrical connection: VP 6.0

Process connection: PG 13.5

Patented reference electrolyte POLISOLVE™

CheckRef™ wire

Diffusion resistance

SINGLE PORE™ hole diaphragm

REF Reference wire

pH half cell wire

pH glass

Pt1000temperature sensor

Inner buffer

Correct temperature compensation

• Measurements at other temperatures than that of calibration require temperature compensation in order to minimize error.

• Electrodes used for an extended period experience a shift in the isotherm intersection point. The measuring device then measures with the wrong parameters for compensation. The measurement values displayed are incorrect.

• pHeasy ® enables the measuring device to emit a warning so that the user uses a new, more accurate electrode.

Simple pHeasy ® alarm signal

alarm limit

Operating time [month]Ch

eckR

ef -

REF

[mV]

alarm limitalarm limit

��

��

��

��

��

��

� � �� ��

60°C20°C

No recalibrating thanks pHeasy ®

Operating time [month]

Max

. dev

iati

on [p

H]

���

����������������

��������������

� � �� ��

60°C20°C

Page 8: Process Sensors Hamilton

– 8 –

Conductivity Standards

HAMILTON is different:

Hamilton offers conductivity standards with different conductivity values, whose stability of ±1% is guaranteed over a life cycle of up to 3 years. These standards can be used several times, on condition that the bottle is not left open (without its lid) for more than 1 hour in total. In order to ensure the accuracy of the conductivity standards a representative number of bottles from each batch is measured by DFM. The DFM value is recorded on the calibration certificate and on each bottle. DFM enjoys the highest prestige in Europe in the area of electrolytic conductivity and is equipped with an absolute measurement cell that was developed in collaboration with NIST and is accredited by the Danish accreditation

HAMILTON Conductivity Standards – leading in long-term stability

Although seemingly a minor matter, calibration and verification of conductivity sensors is far from simple. This is particularly the case with measurements in the low conductivity range, for which stable and reliable calibration standards have been completely lacking up to now. Since a conductivity standard is not a buffer solution, contamination or entry of CO2 has a much greater effect the lower the value of the conductivity standard. Hamilton is the first manufacturer to offer conductivity standards in 1.3 and 5 μS/cm with a certified accuracy of ±1 %, and a lifetime of 1 and 3 years respectively. The composition of these standards is patented, and the procedure for determining conductivity has been developed in collaboration with DFM1). State metrological institutes that deal with measurement of electrolytic conductivity have become aware of Hamilton standards since they lie in a low conductivity range and exhibit the type of stability that has never been achieved before (see illus., Stability over 3 years, with test measurements by PTB2). During an interlaboratory test among prestigious European metrological institutes (PTB , DFM, DKD3) Hamilton standards were used as a measurement solution.

agency DANAK to a conductivity of 0.9 μS/cm. DFM and NIST4) have made comparisons of their measurement uncertainty and have confirmed in a series of scientific publications that the measurement accuracy is in each case the same. Since in the low conductivity range no primary standards exist, we depend on absolute measurement cells which trace electrical conductivity back to the SI units meter and volt. Testing of Hamilton standards is thus carried out on the most precise measurement apparatus in the world and certified accordingly.

1) DFM: Danish Institue of Fundamental Metrology

2) PTB: Physikalisch-Technische Bundesanstalt,

Braunschweig, Germany

3) DKD: Deutscher Kalibrierdienst, Germany

4) NIST: National Institute of Standards and

Technology, Gaithersburg MD, USA

Page 9: Process Sensors Hamilton

– 9 –

Diagramm1

Page 1

4.95

4.96

4.97

4.98

4.99

5.00

5.01

5.02

5.03

5.04

5.05

0 11 16 21 26 37

• Stable for at least 1 year (1.3 µS/cm), up to 3 years• Certified standards with traceable calibration from DFM (can be viewed at www.hamiltoncompany.com/cert)• Expiration date on every bottle• Bottles can remain open for up to 60 minutes and retain the certified value.

Unique Advantages:3-year stability

Value at 25°C Accuracy Stability [Months] Certified by Package Order No.

1.3 µS/cm ± 1% 12 DFM Glass bottle 300 mL 238 973

5 µS/cm ± 1% 36 DFM Glass bottle 300 mL 238 926

15 µS/cm ± 1% 36 DFM Glass bottle 300 mL 238 927

84 µS/cm ± 1% 18 DFM 1 Calpack bottle 500 mL 238 984

100 µS/cm ± 1% 36 DFM Glass bottle 300 mL 238 934

147 µS/cm ± 1% 18 DFM 1 Calpack bottle 500 mL 238 985

1413 µS/cm ± 1% 36 DFM Glass bottle 300 mL 238 928

1413 µS/cm ± 1% 18 DFM 1 Calpack bottle 500 mL 238 986

12288 µS/cm ± 1% 18 DFM 1 Calpack bottle 500 mL 238 988

Conductivity Standards

cond

uctiv

ity [µ

S/cm

]

shelf life [month]

nominal 5µS/cmactual value

Page 10: Process Sensors Hamilton

– 10 –

Features• Convenient 250 mL and 500 mL plastic bottle with built-in calibration compartment• Economical, since only about 20 mL of buffer is used per calibration• Actual value is determined by a DKD laboratory, accredited for pH measurement• First class certifi cate with traceability to international standards• Certifi cates available at http://www.hamiltoncompany.com/cert• Expiration date on the bottle • Immune to micro-organisms

Can you trust your buffer solution?GMP, GLP, ISO 9001, EN 45000, calibration, verifi cation, traceability, certifi cation from an accredited organization: key words that are increasingly important. The calibration of pH and Redox electrodes has never been easy. All calibration procedures assume that the labeled values of the calibration buffers are correct. But buffer values can change over time and so can your results.A complete range of patented buffer solutions, provides never before achieved pH stability. Hamilton guarantees DURACAL pH buffers for 5 years after the date of manufacture. The pH 9.21 and pH 10.01 buffers are even stable in air. See the diagram below for details. High buffering capacity provides rapid, stable calibration. Preservatives are added to prevent microbial and mold growth.

TraceabilityAn important issue for the production of Certified Reference Material is to ensure the traceability through an unbroken chain of comparisons to reference material of the highest metrological quality (Primary Reference Material) from NIST1) and PTB2) .Unlike other manufacturers where only a top-down traceability is applied, Hamilton works with a circular or closed-loop traceability. This closed-loop trace-ability ensures the users of Hamilton DURACAL buffers’ unique reliability!

Top-down traceability: At Hamilton, the pH value of DURACAL buffers is determined by comparison against two Secondary Reference Buffer Solutions. These are purchased from accredited suppliers for Secondary Reference Materials. The solutions themselves are compared against Primary Reference Solutions from PTB1) or NIST 2). The measurement uncertainties from each measurement comparison are known and documented.

Bottom-up traceability: To ensure the highest possible accuracy and full reliability of the pH value, a representative number of samples from every single production lot is sent to a German DKD3) laboratory (DKD-K-06901) for an external, independent and impartial verification. In this laboratory, the DURACAL samples are compared against Secondary Reference Solutions from DKD-K-06901.The Secondary Reference Solutions are of course compared against Primary Reference Solutions from PTB. At this stage, the loop is closed: the PTB Primary Reference Solution is the starting and end point of the traceability loop. DKD provides Hamilton with a calibration certificate for every DURACAL production lot. Due to the complete traceability of the measurement procedure and the assignment of uncertainties to the particular testing steps, the DURACAL buffers can be classified as “certified reference material “ (CRM-certified reference material).

1) NISTNational Institute of Standards and Technology,Gaithersburg MD, USA2) PTBPhysikalisch Technische Bundesanstalt, Braunschweig, Germany

3) DKDDeutscher Kalibrierdienst DKD-K-06901, Zentrum für Messen und Kalibrieren GmbH,Wolfen, Germany

DURACAL pH Buffers: certified for the highest accuracy by an external, accredited laboratory

Page 11: Process Sensors Hamilton

– 11 –

DURACAL pH Buffers: certified for the highest accuracy by an external, accredited laboratory

Simple handling for professional operation:

Step 1: Open bottle

Step 2: Squeeze to fill

Step 3: Calibrate

Step 4: Empty

RedoxRedox value value AccuracyAccuracy StabilityStability(months)(months)

CertificateCertificate Package Package contentscontents

Order Order No.No.

271 mV271 mV ± 5 mV± 5 mV 2424 nonenone 500500 mL mL 238 228238 228

475 mV475 mV ± 5 mV± 5 mV 2424 nonenone 25250 mL0 mL 238 238 322322

475 mV475 mV ± 5 mV± 5 mV 2424 nonenone 500 mL500 mL 238 238 227227

pHpH value value AccuracyAccuracy StabilityStability(months)(months)

CCertifiedertified byby Package Package contentscontents

Order Order NNo.o.

1.091.09 ± 0.02± 0.02 6060 HamiltonHamilton 500 mL500 mL 238 271238 271

1.681.68 ± 0.02± 0.02 6060 HamiltonHamilton 500 mL500 mL 238 272238 272

2.002.00 ± 0.02± 0.02 6060 HamiltonHamilton 500 mL500 mL 238 273238 273

3.063.06 ± 0.02± 0.02 6060 HamiltonHamilton 500 mL500 mL 238 274238 274

4.014.01 ± 0.01 / ± 0.01 / ±± 0.02 0.02 2424 / 60 / 60 DKDDKD 250 mL250 mL 238 317238 317

4.014.01 ± 0.01 / ± 0.01 / ±± 0.02 0.02 2424 / 60 / 60 DKDDKD 500 mL500 mL 238 217238 217

4.014.01 ± 0.01 / ± 0.01 / ±± 0.02 0.02 2424 / 60 / 60 DKDDKD 3 x 500 mL3 x 500 mL 238 917238 917238 917238 917

4.014.01 ± 0.01 / ± 0.01 / ±± 0.02 0.02 2424 / 60 / 60 DKDDKD 5 L5 L 238 332238 332238 332238 332

4.014.01 ± 0.01 / ± 0.01 / ±± 0.02 0.02 2424 / 60 / 60 DKDDKD 10 L10 L 238 194238 194238 194238 194

4.014.01 ± 0.01 / ± 0.01 / ±± 0.02 0.02 2424 / 60 / 60 DKDDKD 1000 L1000 L 238 895 238 895 238 895 238 895

5.005.00 ± 0.02± 0.02 6060 HamiltonHamilton 500 mL500 mL 238 275238 275238 275238 275

6.006.00 ± 0.02± 0.02 6060 HamiltonHamilton 500 mL500 mL 238 276238 276238 276238 276

7.007.00 ± 0.01 / ± 0.01 / ± ± 0.020.02 2424 / 60 / 60 DKDDKD 250 mL250 mL 238 318238 318238 318238 318

7.007.00 ± 0.01 / ± 0.01 / ± ± 0.020.02 2424 / 60 / 60 DKDDKD 500 mL500 mL 238 218238 218238 218238 218

7.007.00 ± 0.01 / ± 0.01 / ± ± 0.020.02 2424 / 60 / 60 DKDDKD 3 x 500 mL3 x 500 mL 238 918238 918238 918238 918

7.007.00 ± 0.01 / ± 0.01 / ±± 0.02 0.02 2424 / 60 / 60 DKDDKD 5 L5 L 238 333238 333238 333238 333

7.007.00 ± 0.01 / ± 0.01 / ±± 0.02 0.02 2424 / 60 / 60 DKDDKD 10 L10 L 238 188238 188238 188238 188

7.007.00 ± 0.01 / ± 0.01 / ±± 0.02 0.02 2424 / 60 / 60 DKDDKD 1000 L1000 L 238 896 238 896 238 896 238 896

8.008.00 ± 0.02± 0.02 6060 HamiltonHamilton 500 mL500 mL 238 277238 277238 277238 277

9.219.21 ± 0.02± 0.02 6060 DKDDKD 250 mL250 mL 238 319238 319238 319238 319

9.219.21 ± 0.02± 0.02 6060 DKDDKD 500 mL500 mL 238 219238 219238 219238 219

9.219.21 ± 0.02± 0.02 6060 DKDDKD 3 x 500 mL3 x 500 mL 238 919238 919238 919238 919

9.219.21 ± 0.02± 0.02 6060 DKDDKD 10 L10 L 238 216238 216238 216238 216

9.219.21 ± 0.02± 0.02 6060 DKDDKD 1000 L1000 L 238 897 238 897 238 897 238 897

10.0110.01 ± 0.02± 0.02 6060 DKDDKD 250 mL250 mL 238 321238 321238 321238 321

10.0110.01 ± 0.02± 0.02 6060 DKDDKD 500 mL500 mL 238 223238 223238 223238 223

10.0110.01 ± 0.02± 0.02 6060 DKDDKD 3 x 500 mL3 x 500 mL 238 923238 923

10.0110.01 ± 0.02± 0.02 6060 DKDDKD 10 L10 L 238 187238 187

10.0110.01 ± 0.02± 0.02 6060 DKDDKD 1000 L1000 L 238 898 238 898

11.0011.00 ± 0.05± 0.05 2424 HamiltonHamilton 500 mL500 mL 238 278238 278

12.0012.00 ± 0.05± 0.05 2424 HamiltonHamilton 500 mL 500 mL 238 279238 279

4.01/7.00/9.214.01/7.00/9.21 ± 0.01 / ± 0.01 / ± 0.02± 0.02 24 / 6024 / 60 DKDDKD 500 mL, mixed500 mL, mixed 238 922238 922

4.01/7.00/10.014.01/7.00/10.01 ± 0.01 / ± 0.01 / ± 0.02± 0.02 24 / 6024 / 60 DKDDKD 500 mL, mixed500 mL, mixed 238 924 238 924

Redox Buffers:

Page 12: Process Sensors Hamilton

– 12 –

pH Pathfinder™ for Pharmaceuticals Industry

Type of PharmaceuticalApplication

Water forInjection

SteamSterilization

Autoclavation

CIP cleanings

TemperatureRange

< 40°CRefillable - Tube connector

< 60°CNon-Refillable

IONOTRODE

pHeasyLIQ-GLASS PG

POLILYTE PLUS

25 ... 130°CNon-Refillable

pHeasy HTPOLILYTE PLUS

12 mmShaft

EASYFERM PLUSpHeasy HT

POLYCLAVE

Also Very Good at Low pHExternal Pressurizable

RefillableCHEMOTRODE

30 mmBulb Body

Extra Protection for ProteinsExternal Pressurizable

RefillableCHEMOTRODE P

1" MNPT INCHTRODE N100

Using aConnector

Cap

EASYFERM PLUSEASYFERMPOLYCLAVE

Using a Connector Cap Helps toKeep the Contacts Dry. Required

for non-VP and non-K8 Types.

VP or K8Connector

EASYFERM PLUS K8EASYFERM PLUS VP

pHeasy HTPOLYCLAVE VP

VP and K8 Connectors Might beWiped off with Pure Ethanol to Dry

and Clean for Long LastingFunction.

12 mmShaft

EASYFERM PLUSEASYFERMpHeasy HT

POLYCLAVE

Also Very Good at Low pHExternal Pressurizable

RefillableCHEMOTRODE30 mm

Bulb Body

Extra Protection for ProteinsExternal Pressurizable

RefillableCHEMOTRODE P

1" MNPT INCHTRODE N100

Non-RefillableUnique Replacement Story FERMOTRODE

In the pharmaceutical industry, many different process applications are used to manufacture a growing number of active ingredients. New technologies improve efficiency or require higher accuracy of the process parameters measured. Other applications require longer measurement signal stability. The only constant is the need to lower costs.

The number of cleaning cycles must be as high as possible for some users, while others change the sensors after every batch. Sensors must fulfill the specified temperature and pressure conditions, and at the same time withstand harsh CIP cleaning.

Easily said AND done – with the right sensor choice! HAMILTON offers what is probably the widest range of pH, dissolved oxygen and conductivity sensors for pharmaceutical applications in the world. The best choice for every process!

The HAMILTON PathfinderTM for pH electrodes provides an easy-to-use guide for choosing the right sensor in pharmaceutical applications. With the specifications mentioned in this catalog, and, if necessary , with the help of one of our process sensor distributors, HAMILTON will fulfill all your pH measurement needs.

If you have specific questions about electrochemical sensors, please contact HAMILTON or one of our distributors.

pH Pathfinder™

Page 13: Process Sensors Hamilton

– 13 –

K8VP

pH: Pharmaceuticals and Fermentation

pHeasy HT

Name Order No.

EASYFERM PlusEASYFERM Plus VPEASYFERM Plus K8

Name Order No.

EASYFERM Plus 120

EASYFERM Plus 225

EASYFERM Plus 325

EASYFERM Plus 425

EASYFERM Plus VP 120

EASYFERM Plus VP 225

EASYFERM Plus VP 325

EASYFERM Plus VP 425

EASYFERM Plus K8 120

EASYFERM Plus K8 160

EASYFERM Plus K8 200

EASYFERM Plus K8 325

EASYFERM Plus K8 425

238 643

238 644

238 645

238 674

238 633

238 634

238 635

238 636

238 625

238 630

238 627

238 628

238 629

Accessory:

Connecting cable (p. 32)

pH: 0 - 14

0 - 135°C

Max. 6 bar at 135°C

Pressurized PHERMLYTE

Reference electrolyte

• Pt100 in a VP version

• Stable measurement signals after steam sterilization, autoclaving and CIP

• Almost drift-free measurement

• Prepressurized PHERMLYTE reference electrolyte ensures a clog-free diaphragm

• High performance „HP“

COATRAMIC diaphragm

• Almost drift-free HAMILTON “PHI“ pH glass

• Several patents granted and pending

• Serialized with batch number

• Test Certificate contains millivolt measurements in 2 pH buffers

pH: 0 - 14

0 - 130 °C

Max. 6 bar at 130 °C

Accuracy monitoring, CheckRef

PT1000

•World‘s first steam-sterilizable pH sensor with build in SAC - Sensor Accuracy Control feature!

• CheckRef for constant monitoring of KCl concentration

• Lengthens service intervals and increases reliability of pH measurement applications

• Sterilizable, autoclavable, CIP

• 2 SINGLE PORE for clog-free contact between measurement medium and POLISOLVE electrolyte

• HAMILTON patented

• Serialized with batch number

• Test Certificate contains millivolt measurements in 2 pH buffers

pHeasy HT 120

pHeasy HT 225

238 893

238 894

Accessories:

Storage solution 500 mL 238 931

Connecting cable (p. 32)

Connection to suitable pH measurement transmitter:Suitable measurement transmitters are those having two inputs (pH/pH or pH/Redox) . The pH measurement is carried out with the first pH input. Connect the CheckRef to the 2nd input (pH glass or Redox connection clamp). If there is a separate 2nd reference connection, bridge this with the first reference input. Use +/- 35 mV or pH < 6.4 and pH > 7.6 as alarm limiting values for any inaccuracies that may occur. More information on p. 7.

EASYFERM

pH: 0 - 14

0 - 130 °C

Max. 4 bar at 130 °C

• Steam-sterilizable and autoclavable

• Stable calibration after sterilization and almost drift-free measurement signals

• 3 COATRAMIC diaphragms prevent clogging by proteins

• EVEREF-F reference cartridge for silver-free SKYLYTE electrolyte

• Almost drift-free HAMILTON “PHI“ pH glass

• Not suitable for use in media with citric acid or in the case of frequent CIP cleaning

• Serialized with batch number

EASYFERM 120

EASYFERM 225

EASYFERM 325

EASYFERM 425

238 490

238 492

238 494

238 498

Accessories:

Storage solution 500 mL 238 931

FLEXIFIT BIO (p. 33)

RETRACTOFIT BIO (p. 37)

Connecting cable (p. 32)

Name Order No.

Page 14: Process Sensors Hamilton

– 14 –

VP

pH: Pharmaceuticals and Fermentation

CHEMOTRODECHEMOTRODE VPCHEMOTRODE ORP

pH: 0 - 14 or

Redox/ORP: +/- 2000 mV

0 - 130 °C; Max. 6 bar

Refillable 3 M KCl-LR

Electrolyte

Pt1000 in VP version

• Precise pH measurement using electrolytes pressurized with air

• Viscous 3 M KCl electrolyte „KCI-LR“

• EVEREF-F reference cartridge extends life cycle in media containing proteins

• Increased reliability of measurement thanks to 3 high-performance ceramic diaphragms

• CHEMOTRODE ORP is the Redox version and is equipped with a large platinum ring

• Can be inserted in almost all pressurizable armatures for electrodes on the market with an electrolyte reservoir

• Serialized with batch number

CHEMOTRODE 120

CHEMOTRODE 150

CHEMOTRODE 200

CHEMOTRODE 250

CHEMOTRODE VP 120

CHEMOTRODE VP 150

CHEMOTRODE ORP 120

CHEMOTRODE ORP 150

CHEMOTRODE ORP 200

CHEMOTRODE ORP 250

Name Order No.

238 760

238 762

238 764

238 766

242 700

242 701

238 740

238 742

238 744

238 746

Accessories:

Storage solution 500 mL 238 931

3 M KCI-LR 500 mL 238 939

e.g. MASTERFIT (p. 35)

Connecting cable (p. 32)

CHEMOTRODE P

pH: 0 - 14

0 - 130 °C

Max. 6 bar

Refillable PROTELYTE Electrolyte

CHEMOTRODE P 120

CHEMOTRODE P 150

CHEMOTRODE P 200

CHEMOTRODE P 250

Name Order No.

238 761

238 763

238 765

238 767

Accessories:

Storage solution 500 mL 238 931

PROTELYTE 100 mL 238 038

e.g. RETRACTOMASTER (p. 38)

Connecting cable (p. 32)

• Precise pH measurement using electrolytes pressurized with air

• PROTELYTE electrolyte

• EVEREF-F reference cartridge extends life cycle in samples containing protein

• Increased security of measurement thanks to 3 high-performance ceramic diaphragms

• Very long life cycle in solutions containing proteins

• Stable measurement values even in partly aqueous solutions

• Can be inserted in almost all pressurizable armatures for electrodes on the market with an electrolyte reservoir

• Serialized with batch number

pH: Sugar Industry, Foods and Beverages

FERMOTRODE

pH: 0...14

0…130 °C

Max. 4 bar

Maintenance-free

FERMOTRODE 120

FERMOTRODE 150

FERMOTRODE 200

FERMOTRODE 250

Name Order No.

238 480

238 482

238 484

238 486

Accessories:

Storage solution 500 mL 238 931

e.g. MASTERFIT (p. 35)

Connecting cable (p. 32)

• Steam-sterilizable

• Long life cycle, very stable calibration values and hardly any drift after sterilization

• No pressurizing required, no risk of an empty electrolyte chamber

• 3 COATRAMIC diaphragms prevent clogging by proteins

• EVEREF-F reference cartridge for silver-free SKYLYTE electrolytes

• HAMILTON “PHI“ pH glass

• Not suitable for use in processes with citric acid or in the case of frequent CIP cleaning

• Serialized with batch number

Page 15: Process Sensors Hamilton

– 15 –

VP VP

INCHTRODE N100F 238 352

Name Order No.

INCHTRODE N100F

pH: 0 - 14

-10 - 130 °C

Max. 10 bar at 25°C

Max. 6 bar at 130 °C

Liquid earth and Pt1000

Accessories:

Storage solution 500 mL 238 931

Connecting cable (p. 32)

Name Order No.

POLYCLAVEPOLYCLAVE VP

pH: 0 - 14

0 - 130 °C

Max. 6 bar at 130 °C

Pt100 in VP version

• POLISOLVE electrolyte (p. 4)

• Highly reproducible measurements after sterilization and other cleanings

• CIP, steam-sterilizable and autoclavable

• Sterility proven in industrial settings

• 2 SINGLE PORE‘s for direct media contact of POLISOLVE electrolyte for reliable measurement results

• Upside-down mounting possible with VP sensor types

• HAMILTON “PHI” pH glass

• Serialized with batch number

• Test Certificate contains millivolt measurements in 2 pH buffers

POLYCLAVE 120

POLYCLAVE 200

POLYCLAVE 225

POLYCLAVE 325

POLYCLAVE VP 120

POLYCLAVE VP 200

POLYCLAVE VP 225

POLYCLAVE VP 325

POLYCLAVE VP 425

238 450

238 453

238 451

238 454

238 455

238 457

238 456

238 458

238 459

Accessories:

Storage solution 500 mL 238 931

FLEXIFIT BIO (p. 33)

RETRACTOFIT BIO (p. 37)

Connecting cable (p. 32)

Name Order No.

POLILYTE HTPOLILYTE HTVP

pH: 0 - 14

0 - 130 °C

Max. 6 bar at 130 °C

Pt100 in HTVP version

• POLISOLVE electrolyte (p. 4)

• Best measurement accuracy both in high-alkali processes and in samples with very low conductivity.

• Sterilizable and autoclavable

• Perfect for the sugar industry

• 2 SINGLE PORE‘s for clog-free contact of electrolyte with measurement medium

• Upside-down mounting possible with VP sensor types

• HAMILTON “H” pH glass

• Serialized with batch number

• Test Certificate contains millivolt measurements in 2 pH buffers

POLILYTE HT 120

POLILYTE HT 225

POLILYTE HT 425

POLILYTE HTVP 120

POLILYTE HTVP 225

POLILYTE HTVP 425

238 431

238 432

238 467

238 428

238 429

238 449

Accessories:

Storage solution 500 mL 238 931

FLEXIFIT BIO (p. 33)

RETRACTOFIT BIO (p. 37)

Connecting cable (p. 32)

pH: Sugar Industry, Foods and Beverages

• Flat pH membrane

• Almost unbreakable PVDF housing (FDA)

• Very long-lasting reference system

• Steam-sterilizable

• Simple installation without additional armature

• MNPT 1“ thread

• SINGLE PORE technology for clog-free contact of electrolyte with medium

• Serialized with batch number

• Test Certificate contains millivolt measurements in 2 pH buffers

Page 16: Process Sensors Hamilton

– 16 –

VP

POLILYTE PROPOLILYTE PRO VPPOLILYTE PRO XP

pH: 0 - 14

-10 - 60 °C

Max. 6 bar at 60 °C or

50 bar in XP version

Pt1000 in VP version

pH: Low Conductivity, Ion-Weak Media

POLILYTE PRO 120

POLILYTE PRO VP 120

POLILYTE PRO XP 120

238 411

238 417

238 811

Name Order No.

• POLISOLVE electrolyte (p. 4)

• Stable measurement values in most ion-weak media

• pH sensors of type POLILYTE PRO XP withstand constant pressure of 50 bar

• POLILYTE PRO VP contains a Pt 1000 temperature sensor

• SINGLE PORE for direct, clog-free contact of the electrolyte with the medium

• Serialized with batch number

• Also consider the POLILYTE PLUS with its high durability and measurement accuracy

• Glass shaft and „V“ pH glass

LIQ-GLASS PG 120 238 515

Name Order No.

LIQ-GLASS PG

pH: 1 - 12

-5 - 60 °C

Max. 2 bar at 60 °C

Maintenance-free - no refilling

• Suitable for process temperatures up to 60°C and samples with conductivity of only 2 μS/cm

• Maintenance-free, simple handling

• A special electrolyte ensures more easily reproducible measurement results in ion-weak samples as compared to traditional sensors

• 3 ceramic diaphragms for flow-independent measurement results

• HAMILTON “F“ pH glass provides stable measurement values

• Serialized with batch number

IONOTRODE 120 238 525

Name Order No.

pH: 0 - 14

-10 - 40 °C

Max. 0.5 bar or higher on

pressurization by side-arm

attachment

• Offers highest accuracy over a long period of time

• Stable measurements in samples with low conductivity of at least 0.2 μS/cm

• Removable PTFE sleeve diaphragm to check electrolyte outflow

• Very large “F“ pH glass membrane and TK inner buffer (p. 5)

• Side-arm attachment via tube to a storage vessel containing 3 M KCl, and control of electrolyte flow with the PTFE diaphragm ring

• Batch number

IONOTRODE

Accessories:

Storage solution 500 mL

3 M KCL, 500 mL

FLEXIFLOW SL 10 (p. 34)

Connecting cable (p. 32)

238 931

238 936

237 340

Accessories:

Storage solution 500 mL

FLEXIFLOW SL 10 (p. 34)

Connecting cable (p. 32)

238 931

237 340

Accessories:

Storage solution 500 mL

FLEXIFLOW SL 10 (p. 34)

FLEXIFIT BIO (p. 33)

Connecting cable (p. 32)

238 931

237 340

Page 17: Process Sensors Hamilton

– 17 –

N75F

N100F

INCHTRODE N75FINCHTRODE N100FINCHTRODE N75FC10

pH: 0 - 14 , -10 - 130 °CMax. 10 bar at 25°CMax. 6 bar at 130 °CLiquid EarthPt1000 (N75F, N100F)

Pt100 (N75FC10)

Name Order No.Name Order No.

INCHTRODE N75F

INCHTRODE N75FC10

INCHTRODE N100F

238 346

238 364

238 352

Accessories:

Storage solution 500 mL 238 931

Connecting cable (p. 32)

• Flat pH membrane

• Almost unbreakable PPS (Ryton) or PVDF(Kynar, FDA) housing

• Very long-lasting reference!

• Single Pore technology for clog-free contact of electrolyte with medium

• Installation without armature

• N75F: NPT ¾“ thread, shaft material PPS, VP head

N100F: MNPT 1“ thread, shaft material PVDF, VP head

N75FC10: NPT ¾“ thread, shaft material PPS, 10m cable

• Serialized number

• Test Certificate contains millivolt measurements in 2 pH buffers

pHeasypHeasy HT

pH: 0 - 14

0 - 60 °C; HT Version: 0 - 130 °C

Max. 6 bar

Accuracy monitoring, CheckRef Pt1000

pHeasy 120

pHeasy HT 120

pHeasy HT 225

238 890

238 893

238 894

pH: Low Conductivity, Ion-Weak Media

• World‘s first pH sensor with build in SAC - Sensor Accuracy Control feature!

• CheckRef for constant KCl concentration monitoring

• Extends service intervals and increases reliability of pH measurement applications

• Upside-down mounting possible

• 2 SINGLE PORE‘s for clog-free contact between measurement solution and POLISOLVE electrolyte

• HAMILTON patented

• Serialized with batch number

• Test Certificate contains millivolt measurements in 2 pH buffers

Accessories:

Storage solution 500 mL 238 931

Connecting cable (p. 32)

Connection to suitable pH measurement transmitter:Suitable measurement transmitters are those having two inputs (pH/pH or pH/Redox). The pH measurement is carried out with the first pH input. Connect the CheckRef to the 2nd input (pH-Glass or Redox connection clamp). If there is a separate 2nd reference connection, bridge this with the first reference input. Use +/- 35 mV or pH < 6.4 and pH > 7.6 as alarm limiting values for any inaccuracies that may occur. More information on p. 7.

Name Order No.

POLILYTE PLUS VP

pH: 0 - 14

0 - 130 °C

Max. 6 bar at 130 °C

Pt1000

• Unbeaten in comparative tests!

• Highly reproducible measurements thanks to POLISOLVE PLUS (p. 4) reference, very stable over long periods of time

• Minimal diffusion potential

• 2 SINGLE PORE‘s for direct contact between POLISOLVE PLUS electrolyte and medium.

• Protected by several patents

• HAMILTON “H“ pH glass, stable for long periods plus a patented reference system

• Upside-down mounting possible

• Serialized number

• Test Certificate contains millivolt measurements in 2 pH buffers

Accessories:

Storage solution 500 mL 238 931

FLEXIFIT BIO (p. 33)

RETRACTOFIT BIO (p. 37)

Connecting cable (p. 32)

POLILYTE PLUS VP 120

POLILYTE PLUS VP 225

POLILYTE PLUS VP 325

POLILYTE PLUS VP 360

POLILYTE PLUS VP 425

242 428

242 429

242 439

242 442

242 449

Page 18: Process Sensors Hamilton

– 18 –

VPK8VP

Name Order No.

pH: Chemical Industry

Name Order No.

POLILYTE PLUS VP

pH: 0 - 14

0 - 130 °C

Max. 6 bar at 130 °C

Pt1000

• Unbeaten in comparative tests!

• Highly reproducible measurements thanks to POLISOLVE PLUS (p. 4) reference, stable over long periods

• Minimal diffusion potentials

• 2 SINGLE PORE‘s for direct contact between POLISOLVE PLUS Electrolyte and medium. No clogging!

• Patent-protected

• HAMILTON “H“ pH glass with low alkali error and patented reference system

• Upside-down mounting possible

• Serialized number

• Test Certificate contains millivolt measurements in 2 pH buffers

POLILYTE HTPOLILYTE HTVP

pH: 0 - 14

0 - 130 °C

Max. 6 bar at 130 °C

Pt100 in HTVP version

POLILYTE HT 120

POLILYTE HT 225

POLILYTE HT 425

POLILYTE HTVP 120

POLILYTE HTVP 225

POLILYTE HTVP 425

238 431

238 432

238 467

238 428

238 429

238 449

Accessories:

Storage solution 500 mL 238 931

FLEXIFIT BIO (p. 33)

RETRACTOFIT BIO (p. 37)

Connecting cable (p. 32)

pH: 0 - 14

0 - 135°C

Max. 6 bar at 135°C

Pressurized PHERMLYTE

Reference electrolyte

EASYFERM PlusEASYFERM Plus VPEASYFERM Plus K8

• Pt100 in VP version

• Almost drift-free measurement

• PHERMLYTE Reference electrolyte factory prepressurized for a clog-free diaphragm and minimized diaphragm potentials

• High performance HP COATRAMIC Diaphragm

• EVEREF-F Reference cartridge for silver-free electrolytes

• Poison resistant „PHI“ pH glass

• Several patents granted and pending

• Serialized with batch number

• Test Certificate contains millivolt measurements in 2 pH buffers

Name Order No.

EASYFERM Plus 120

EASYFERM Plus 225

EASYFERM Plus 325

EASYFERM Plus 425

EASYFERM Plus VP 120

EASYFERM Plus VP 225

EASYFERM Plus VP 325

EASYFERM Plus VP 425

EASYFERM Plus K8 120

EASYFERM Plus K8 160

EASYFERM Plus K8 200

EASYFERM Plus K8 325

EASYFERM Plus K8 425

238 643

238 644

238 645

238 674

238 633

238 634

238 635

238 636

238 625

238 630

238 627

238 628

238 629

Accessory:

Connecting cable (p. 32)

Accessories:

Storage solution 500 mL 238 931

FLEXIFIT BIO (p. 33)

RETRACTOFIT BIO (p. 37)

Connecting cable (p. 32)

• POLISOLVE Electrolyte (p. 4)

• Best measurement accuracy both in high-alkali processes and in samples with very low conductivity.

• Performance proven in industrial applications

• 2 SINGLE PORE‘s for direct medium contact with the POLISOLVE Electrolyte for the best measurement results

• Upside-down mounting possible with VP sensor types

• HAMILTON “H” pH glass

• Serialized with batch number

• Test Certificate contains millivolt measurements in 2 pH buffers

POLILYTE PLUS VP 120

POLILYTE PLUS VP 225

POLILYTE PLUS VP 325

POLILYTE PLUS VP 360

POLILYTE PLUS VP 425

242 428

242 429

242 439

242 442

242 449

Page 19: Process Sensors Hamilton

– 19 –

VPVP

pH: 0 - 14

-10 - 100 °C

Max. 6 bar at 100 °C

For < 0.01M / 200 mg/l HF at 20 °C

or 0.05M / 1000 mg/l HF at 50 °C

pH: Chemical Industry, Oxides

Name Order No.Name Order No.

• Maintenance-free reference gel electrolyte

• 3 high-performance ceramic diaphragms for reduced flow potentials during pipe mounting

• HAMILTON “H“ pH glass offers the best measurement accuracy at high pH values or high temperatures

• OXYTRODE PT is a Redox sensor with a platinum wire coil welded to the glass

• Serialized with batch number

MECOTRODE 120

MECOTRODE 225

MECOTRODE VP 120

OXYTRODE PT 120

238 801

238 806

238 437

238 810

MECOTRODEMECOTRODE VPOXYTRODE PT

pH: 0 - 14 or

Redox: +/- 2000 mV

0 - 130 °C; Max. 16 bar at

25 °C or. 6 bar at 130 °C

Pt100 in VP version

CLARYTRODE 120

CLARYTRODE VP 120

238 821

238 831

Name Order No.

CLARYTRODECLARYTRODE VP

• It‘s a POLISOLVE Sensor (p. 4)

• HF applications containing oxides destroy normal pH glass when pH values are low

• HAMILTON “HF“ pH glass withstands HF better than other pH glasses. This significantly extends sensor life.

• Stable measurement values under tough conditions

• 2 SINGLE PORE‘s for interference-free contact of POLISOLVE electrolyte with measurement medium

• Pt100 in the VP version

• Serialized with batch number

• Test Certificate contains millivolt measurements in 2 pH buffers

Accessories:

Storage solution 500 mL 238 931

FLEXIFIT BIO (p. 33)

RETRACTOFIT BIO (p. 37)

Connecting cable (p. 32)

Accessories:

Storage solution 500 mL 238 931

FLEXIFIT BIO (p. 33)

Connecting cable (p. 32)

pHeasypHeasy HT

pHeasy 120

pHeasy HT 120

pHeasy HT 225

238 890

238 893

238 894

Accessories:

Storage solution 500 mL 238 931

Connecting cable (p. 32)

Connection to suitable pH measurement transmitter:Suitable measurement transmitters are those having two inputs (pH/pH or pH/Redox). The pH measurement is carried out with the first pH input. Connect the CheckRef to the 2nd input (pH-Glass or Redox connection clamp). If there is a separate 2nd reference connection, bridge this with the first reference input. Use +/- 35 mV or pH < 6.4 and pH > 7.6 as alarm limiting values for any inaccuracies that may occur. More information on p. 7.

pH: 0 - 14

0 - 60 °C; HT Version: 0 - 130 °C

Max. 6 bar

Accuracy monitoring, CheckRef, Pt1000

• The first pH sensor in the world with built-in accuracy monitoring!

• CheckRef for constant monitoring of KCl concentration

• Extends service intervals and increases reliability of pH measurement applications

• Upside-down mounting possible

• 2 SINGLE PORE‘s for clog-free contact between measurement medium and POLISOLVE electrolyte

• HAMILTON patented

• Serialized with batch number

• Test Certificate contains millivolt measurements in 2 pH buffers

Page 20: Process Sensors Hamilton

– 20 –

VP VP

pH: Chemical Industry

CHEMOTRODECHEMOTRODE VPCHEMOTRODE ORP

pH: 0 - 14 or

Redox: +/- 2000 mV

0 - 130 °C; Max. 6 bar

Refillable 3 M KCl-LR Electrolyte

Pt1000 in VP version

• Viscous 3 M KCl Electrolyte “KCl-LR“ air-pressurizable for low interference potentials

• EVEREF-F reference cartridge extends electrode life in aggressive media

• 3 high-performance ceramic diaphragms for significantly higher measurement security

• CHEMOTRODE ORP is the Redox version with a large platinum ring

• Serialized with batch number

• Insertable into almost all pressurizable armatures for electrodes with an electrolyte reservoir

CHEMOTRODE 120

CHEMOTRODE 150

CHEMOTRODE 200

CHEMOTRODE 250

CHEMOTRODE 550

CHEMOTRODE VP 120

CHEMOTRODE VP 150

CHEMOTRODE ORP 120

CHEMOTRODE ORP 150

CHEMOTRODE ORP 200

CHEMOTRODE ORP 250

Name Order No.

238 760

238 762

238 764

238 766

238 775

242 700

242 701

238 740

238 742

238 744

238 746

pH: 0 - 14

0 - 130 °C

Max. 6 bar

Refillable SKYLYTE Electrolyte

Pt100 in VP version

Name Order No.

CHEMOTRODE BRIDGECHEMOTRODE BRIDGE VP

• Problem-solving pH sensor that works longer

• SKYLYTE Electrolyte, air-pressurizable for a clog-free diaphragm

• EVEREF-B reference cartridge for maximum protection of the reference half-cell and use of silver-free SKYLYTE Electrolyte

• 1 platinum diaphragm for clog-free functioning

• HAMILTON “PHI” pH glass

• H-XL version with extra-strong “H“ pH glass for abrasive media

• Serialized with batch number

CHEMOTRODE BRIDGE 120

CHEMOTRODE BRIDGE 150

CHEMOTRODE BRIDGE 200

CHEMOTRODE BRIDGE 250

CHEMOTRODE BRIDGE VP 120

CHEMOTRODE BRIDGE VP 150

CHEMOTRODE BRIDGE H-XL150

238 770

238 772

238 774

238 776

238 753

238 754

238 756

CHEMOTRODE P

pH: 0 - 14

0 - 130 °C

Max. 6 bar

Refillable PROTELYTE Electrolyte

• Like CHEMOTRODE, but:

• Air-pressurizable PROTELYTE Electrolyte, which enables more stable measurements in partly aqueous samples and causes fewer problems in media containing proteins

• Particularly suitable for use in precipitation reactions

CHEMOTRODE P 120

CHEMOTRODE P 150

CHEMOTRODE P 200

CHEMOTRODE P 250

Name Order No.

238 761

238 763

238 765

238 767

Accessories:

Storage solution 500 mL

SKYLYTE 100 mL

SKYLYTE 500 mL

e.g. MASTERFIT (p. 35)

Connecting cable (p. 32)

238 931

238 037

238 937

Accessories:

Storage solution 500 mL

3 M KCl-LR 500 mL

Connecting cable (p. 32)

238 931

238 939

Accessories:

Storage solution 500 mL

PROTELYTE 100 mL

e.g. MASTERFIT (p. 35)

Connecting cable (p. 32)

238 931

238 038

Page 21: Process Sensors Hamilton

– 21 –

N75F

N75PC10

pH: Chemical Industry and Paper Making

Name Order No.

DELTATRODEINCHTRODE N75FINCHTRODE N75PINCHTRODE N75FC10INCHTRODE N75PC10

Name Order No.

INCHTRODE N75F

INCHTRODE N75P

INCHTRODE N75FC10

INCHTRODE N75PC10

238 346

238 342

238 364

238 359

pH: 0 - 14 -10 - 130 °CMax. 10 bar at 25°CMax. 6 bar at 130 °CLiquid EarthPt 1000 (N75F, N75P)Pt 100 (N75FC10, N75PC10)

Accessories

Storage solution 500 mL 238 931

Connecting cable (p. 32)

• 10 m fixed cable (C10)or VP head version

• Almost unbreakable PPS (Ryton) housing

• Flat (F) or protected (P) pH membrane

• Reference system very stable for long periods

• Single Pore technology for clog-free contact of electrolyte with medium

• HAMILTON “HF”pH glass (F) or “PHI“ glass (P)

• NPT 3/4“ thread

• Serialized

• Test Certificate contains millivolt measurements in 2 pH buffers

INCHTRODE N100F 238 352

Name Order No.

INCHTRODE N100F

pH: 0 - 14 -10 - 130 °CMax. 10 bar at 25°CMax. 6 bar at 130 °CLiquid EarthPt 1000

Accessories:

Storage solution 500 mL 238 931

Connecting cable (p. 32)

• Flat pH membrane

• Almost unbreakable PVDF housing (FDA)

• Reference system very stable for long periods

• Steam-sterilizable

• Simple installation without additional armature

• MNPT 1“ thread

• Single Pore technology for clog-free contact of electrolyte with medium

• HAMILTON “HF”pH glass

• Serialized

• Test Certificate contains millivolt measurements in 2 pH buffers

pH: 0 - 14, 0 - 60°C

Max. 2 bar at 60°C

Differential pH Electrode

Liquid Earth

Pt 1000

• Outstanding solution for processes with typical reference poison such as sulfide

• Functions without usual silver/silver chloride reference system, but instead with a built-in pH half-cell which produces a stable reference signal in a pH buffer solution.

• Built-in Pt 1000

• Prepressurized DELTALYTETM reference buffer ensures a clog-free diaphragm

• High-performanceHP ceramic diaphragm

• Built-in liquid earth

• Serialized with batch number

238 640

Accessories:

Storage solution 500 mL 238 931

FLEXIFIT BIO (p. 33)

Connecting cable (p. 32)

DELTATRODE 120

Suitable pH measurement converters:As a rule all measurement converters can be used whose pH and reference inputs are high-ohm (differential input). The liquid earth should always be hooked up for the DELTATRODE.

Page 22: Process Sensors Hamilton

– 22 –

VP

pH: Swimming Pools, Sea Water, Ground Water, Drinking Water, Waste Water, Fish Farming

POLILYTE PRO 120

POLILYTE PRO VP 120

POLILYTE PRO XP 120

POLILYTE RX 120

POLILYTE RX 225

POLILYTE PROPOLILYTE PRO VPPOLILYTE PRO XPPOLILYTE RXpH: 0 - 14 orRedox: +/- 2000 mV-10 - 60 °CMax. 6 bar at 60 °C or 50 bar in XP versionPt1000 in VP version

• It has POLISOLVE Electrolyte (pg. 4)!

• Suitable for process temperatures up to 60 °C

• POLILYTE PRO XP pH sensors withstand continuous pressure of 50 bar!

• POLILYTE PRO VP sensors are equipped with a built-in Pt1000

• POLILYTE RX is the redox sensor version of the same product family

• SINGLE PORE for direct sample contact with the POLISOLVE electrolyte. No clogging!

• Glass shaft and “V“ pH glass

• Serialized with batch number

Accessories:

Storage solution 500 mL

FLEXIFIT BIO (p. 33)

Connecting cable (p. 32)

Accessories:

Storage solution 500 mL

FLEXIFIT BIO (p. 33)

RETRACTOFIT BIO (p. 37)

Connecting cable (p. 32)

EASYCONTROL 120

EASYCONTROL ORP 120

238 522

238 523

EASYCONTROLEASYCONTROL ORP

pH: 0 - 14 or

Redox: +/- 2000 mV

0 - 60 °C

Max. 2 bar at 60 °C

• Suitable for non-demanding applications

• EASYCONTROL is the pH sensor

• EASYCONTROL ORP is the redox sensor version of the same product family

• Ceramic diaphragm liquid junction

• Serialized with batch number

Accessories:

Storage solution 500 mL

FLEXIFIT BIO (p. 33)

Connecting cable (p. 32)

Name Order No.Name Order No.

238 411

238 417

238 811

238 433

238 434

POLYPLAST PRO

POLYPLAST PRO RX

POLYPLAST PROPOLYPLAST PRO RX

pH: 0 - 14 or

Redox: +/- 2000 mV

-10 - 40 °C (briefly 60°C)

Max. 6 bar at 60 °C

Name Order No. 238 408

238 409

• Economical and long lasting pH and Redox sensors

• It has POLISOLVE Electrolyte (pg. 4)!

• Epoxy shaft with pH glass bulb protection

• Suitable for process temperatures up to 60 °C

• POLILYTE RX is the redox sensor version of the same product family

• SINGLE PORE for direct sample contact with the POLISOLVE electrolyte. No clogging!

• HAMILTON “V” pH glass for quick response and stable readings even at low temperatures

• Serialized with batch number

238 931

238 931 238 931

Page 23: Process Sensors Hamilton

– 23 –

VPVP

pH: Swimming Pools, Sea Water, Ground Water, Drinking Water, Waste Water, Fish Farming

• It has POLISOLVE Electrolyte (pg. 4)

• Applications containing Hydrofluoric acid dissolve normal pH glasses within hours at low pH values

• HAMILTON "HF" pH glass is much more resistant to HF than other pH glasses. This significantly increases sensor lifetime

• Stable readings in harsh conditions

• Two SINGLE POREs for direct sample contact with the POLISOLVE electrolyte

• Pt100 in VP type

• Serialized with batch number

• Test Certificate contains millivolt measurements in 2 pH buffers

pH: 0 - 14

-10 - 100 °C

Max. 6 bar at 100 °C

For < 0.01M / 200 mg/l HF at 20 °C

or 0.05M / 1000 mg/l HF at 50 °C

• Maintenance free reference gel electrolyte

• 3 high performance ceramic diaphragms for reduced flowing potentials when mounted in pipes

• Hamilton “H” pH glass provides the most accurate readings at high pH values or high temperatures

• OXYTRODE PT is a Redox sensor with a platinum wire coil welded onto the glass

• Serialized with batch number

MECOTRODEMECOTRODE VPOXYTRODE PT

pH: 0 - 14 or

Redox: +/- 2000 mV

0…130 °C; Max. 16 bar at

25 °C or 6 bar at 130 °C

Pt100 in VP version

pHeasy

pH: 0 - 14

0 - 60 °C

Max. 6 bar

Accuracy monitoring, CheckRef

Pt1000

• World‘s first pH sensor with build in SAC - Sensor Accuracy Control feature!

• CheckRef for permanent KCl-concentration control and early warning when reference becomes poisoned by the process

• Expands the accuracy of pH measurements without recalibration.

• 2 SINGLE POREs so the POLISOLVE directly contacts the sample for best results

• Measures 1 year without recalibration in municipal wastewater

• Serialized with batch number

• Inspection certificate

• See also p. 7.

Name Order No. pHeasy 120 238 890

Accessories:

Storage solution 500 mL

Connecting cable (p. 32)

Connection to suitable pH measurement transmitter:Suitable measurement transmitters are those having two inputs (pH/pH or pH/Redox). The pH measurement is carried out with the first pH input. Connect the CheckRef to the 2nd input (pH-Glass or Redox connection clamp). If there is a separate 2nd reference connection, bridge this with the first reference input. Use +/- 35 mV or pH < 6.4 and pH > 7.6 as alarm limiting values for any inaccuracies that may occur. More information on p. 7.

Name Order No. CLARYTRODE 120

CLARYTRODE VP 120

238 821

238 831

CLARYTRODECLARYTRODE VP

Accessories:

Storage solution 500 mL

FLEXIFIT BIO (p. 33)

Connecting cable (p. 32)

Name Order No.

MECOTRODE 120

MECOTRODE 225

MECOTRODE VP 120

OXYTRODE PT 120

238 801

238 806

238 437

238 810

Accessories:

Storage solution 500 mL

FLEXIFIT BIO (p. 33)

RETRACTOFIT (p. 36)

Connecting cable (p. 32)

238 931

238 931

238 931

Page 24: Process Sensors Hamilton

– 24 –

VP

N75FC10

N75P

pH: Waste Water

pH: 0 - 14

0 - 130 °C

Max. 6 bar

Refillable SKYLYTE Electrolyte

Pt100 in VP version

• Problem-solving pH sensor that operates for longer

• SKYLYTE Electrolyte, air-pressurizable for a clog-free diaphragm

• EVEREF-B reference cartridge for maximum protection of the reference half-cell and use of silver-free SKYLYTE Electrolyte

• 1 platinum diaphragm for clog-free functioning

• HAMILTON “PHI” pH glass

• H-XL version with extra-strong “H“ pH glass for abrasive media

• Serialized with batch number

CHEMOTRODE BRIDGECHEMOTRODE BRIDGE VP

CHEMOTRODE BRIDGE 120

CHEMOTRODE BRIDGE 150

CHEMOTRODE BRIDGE 200

CHEMOTRODE BRIDGE 250

CHEMOTRODE BRIDGE VP 120

CHEMOTRODE BRIDGE VP 150

CHEMOTRODE BRIDGE H-XL150

238 770

238 772

238 774

238 776

238 753

238 754

238 756

DELTATRODE

Name Order No.

INCHTRODE N75FINCHTRODE N75PINCHTRODE N75FC10INCHTRODE N75PC10

Name Order No.

Accessories:

Storage solution 500 mL 238 931

Connecting cable (p. 32)

pH: 0 - 14 , 0 - 60°C

Max. 2 bar at 60°C

Differential pH-Electrode

Liquid Earth

Pt 1000

• Outstanding solution for processes with typical reference poison such as sulfide

• Functions without usual silver/silver chloride reference system, but instead with a built-in pH half-cell which produces a stable reference signal in a pH buffer solution.

• Built-in Pt 1000

• Prepressurized DELTALYTETM Reference buffer ensures a clog-free diaphragm

• High-performanceHP ceramic diaphragm

• Built-in liquid earth

• Serialized with batch number

DELTATRODE 120

Suitable pH measurement converters:As a rule all measurement converters can be used whose pH and reference inputs are high-ohm (differential inlet). The liquid earth should always be hooked up for the DELTATRODE.

238 640

Accessories:

Storage solution 500 mL 238 931

FLEXIFIT BIO (p. 33)

Connecting cable (p. 32)

INCHTRODE N75F

INCHTRODE N75P

INCHTRODE N75FC10

INCHTRODE N75PC10

238 346

238 342

238 364

238 359

pH: 0 - 14 -10 - 130 °CMax. 10 bar at 25°CMax. 6 bar at 130 °CLiquid EarthPt 1000 (N75F, N75P)Pt 100 (N75FC10, N75PC10)

• 10 m fixed cable (C10) or VP connector head version

• Almost unbreakable PPS (Ryton) housing

• Flat (F) or protected (P) pH membrane

• Reference system very stable for long periods

• Single Pore technology for clog-free contact of electrolyte with medium

• HAMILTON “HF”pH glass (F) or “PHI“ glass (P)

• NPT 3/4“ thread

• Serialized

• Test certificate contains millivolt measurements in 2 pH buffers

Accessories:

Storage solution 500 mL

SKYLYTE 100 mL

SKYLYTE 500 mL

MASTERFIT (p. 35)

Connecting cable (p. 32)

238 931

238 037

238 937

Name Order No.

Page 25: Process Sensors Hamilton

– 25 –

pH-SIMULATOR LAB

pH-SIMULATOR PRO

pH: Waste Water pH Simulator, Temperature Sensor

pH SIMULATOR PRO

Simulates pH and Redox sensors in buffer

For testing cables and measurement devices

16 test values, including NIST pH buffer values

Testing of pH inlet resistance (Hi Z)

Adapter cable for BNC, standard S7 plug

• Easy and safe operation using high-quality touch buttons

• Simple one hand operation

• Large, easy-to-read illuminated display

• Testing of high-ohm measurement device inlet resistance. Also test commonly encountered, poorly insulated pH cables

• Battery level display ensures correct operation and eliminates unnecessary battery changes

• The simulator front is waterproof

• DKD certificate with actual mV values available as an option.

The same as the SIMULATOR LAB but also includes:

• rubber protective cover with collapsible support

• Adapter cable for VP plug with

Pt100 and Pt1000 simulation at 25°C

• Case with room for 2 x 250 mL pH buffer

pH SIMULATOR LAB

Name Order No.

pH SIMULATOR LAB

pH SIMULATOR LAB with certificate

pH SIMULATOR PRO

pH SIMULATOR PRO with certificate

Spare parts:

Rubber protective cover

Accessories:

DURACAL pH buffer pH 4.01, 250 mL

DURACAL pH buffer pH 7.00, 250 mL

DURACAL pH buffer pH 9.21, 250 mL

DURACAL pH buffer pH 10.01, 250 mL

237 556

237 560

237 550

237 566

237 552

238 317

238 318

238 319

238 321

SpecificationsSpecificationspH simulationpH simulation values values pH 1.00, 1.68, 4.01, 6.86, 7.00, 9.18, 10.01, 12.45pH 1.00, 1.68, 4.01, 6.86, 7.00, 9.18, 10.01, 12.45

pH simulationpH simulation accuracy accuracy +/- 0.02 pH+/- 0.02 pH

mV simulation values mV simulation values -1800, -900, -390, +390, +900, +1800 mV-1800, -900, -390, +390, +900, +1800 mV

mV simulationmV simulation accuracy accuracy +/- 1 mV+/- 1 mV

pH input resistance test (Hi Z)pH input resistance test (Hi Z) 1 Gohm1 Gohm at pH 4.01 and 10.01 at pH 4.01 and 10.01

DisplayDisplay LEDs,LEDs, values separatedvalues separated for ease of recognitionfor ease of recognition

OutputOutput BNC connector; various adapter cablesBNC connector; various adapter cables

BatterBattery state displayy state display LEDLED

Power sourcePower source 4 4 ‘‘AAAAAA‘‘AAA‘‘ ’ ’ AAAAAA’ AAAAAA BBatterieatteriess

Operating Operating temperaturetemperature 0 - 400 - 40°°CC

Permissible air humidityPermissible air humidity 80% up to 380% up to 300°°C, linear decrease up to 50% at 40C, linear decrease up to 50% at 40°°CC

MeasurementsMeasurements ca. 140 x 170 x 35 ca. 140 x 170 x 35 mmmm

Testing cable and measurement devices:Typically, failures of pH measurement are attributed to defective or poorly-chosen pH sensors. But often the cause is poor-quality, worn or defective pH cables, which no longer fulfill the high demands of insulation resistance. Not to be forgotten are similar faults in measurement devices that make reliable pH measurement impossible! These problems can be detected with the pH Simulator and costly and time-consuming trials of different electrodes can be avoided.

ISO 9000 test device monitoring:To adapt the pH Simulator for ISO 9000-compliant test device monitoring on the shop floor, the device needs to be certified by DKD, the German calibration service, which is accredited by PTB (Physikalisch-Technische Bundesanstalt), Braunschweig, for the measurements involved. The DKD certificate contains the actual mV values which must be displayed by the measurement device being tested within the given tolerances.

pH SimulatorsApplications for pH Simulators:• Testing cable and measurement

devices• ISO 9000 test device monitoring

with DKD certificate

• With the SIMULATOR PRO, the rubber protective cover guards against slippage, mechanical damage, and also helps to prop up the device for ease of readability.

• The SIMULATOR PRO is equipped with extra adapter cables for VP cable tests including Pt100 or Pt1000 simulation.

• DKD certificate with actual mV values available as an option.

Page 26: Process Sensors Hamilton

– 26 –

Oxygen Sensors

Measurement principleThe oxygen content in liquids is best measured with cells using Clark's prin-ciple. These cells generate an electrical current proportional to the oxygen partial pressure which can be evalua-ted with a suitable measurement con-verter. In order to prevent interference effects, the Clark's cell is covered with a gas-permeable membrane. The PTFE membranes typically used, however, are mechanically very fragile, with the result that they must be frequently changed to allow reliable measure-ment. It is difficult to handle such fragile membranes.

As a solution, HAMILTON developed the OPTIFLOW membrane. This mem-brane is very mechanically stable and is manufactured as a laminate around a steel mesh. OPTIFLOW membranes are stable under harsh ambient con-ditions as well as high pressures. This ingenious design allows fast response times to be combined with unusually low flow dependence.

Oxygen measurement today is performed in a very wide range of applications and is one of the most important parameters of process control technology. Since their introduction in 1995, HAMILTON oxygen sensors have become world leaders because of their signal performance and low maintenance requirements.

Building on the success of the first OXYFERM sensor, our family of oxygen sensors has been continuously extended and now comprises three groups. The OXYGOLD sensor with its very low limit of detection has ideal properties for applications in brewing, boiler feed water and for all applications requiring a low limit of detection. The sterilizable and autoclavable OXYFERM sensors represent a new standard in biotechnology. In addition to the PG 13.5 versions with their various lengths, they are now also available as 25 mm versions. The OXYSENS sensors have been developed as 100% maintenance-free, low cost sensors for water management and fish farming.

What is important for oxygen measurements?

Outstanding performanceShort response timesThe outstanding properties of the new membrane material result in fast response times of 30 to 60 seconds.

Low maintenance and long lifeMaintenance is rarely necessary due to the improved design of the sen-sor. The construction of the electro-de guarantees excellent stability even after numerous sterilization cycles. The graph illustrates the excellent perfor-mance of OXYFERM electrodes even after 100 sterilizations without the need for maintenance. Other types of oxygen sensor subjected to the same conditions require maintenance after 5 to 10 sterilization cycles.

especially with slowly flowing samp-les. This can lead to excessively low or erratic readings. As a result of the OXYFERM design, the effect of the flow rate on the reading is negligible.

Short stabilization timeThe stabilization time is the time bet-ween connection of the oxygen sensor to the amplifier and the time when accurate measurements can be expec-ted. This is due to the oxygen, which has diffused inside the sensor and is present around the cathode when no voltage is applied. The OXYSENS sta-bilization time is typically less than 15 minutes.

Low flow sensitivityMany other oxygen sensors show a clear dependence on the flow rate

Page 27: Process Sensors Hamilton

– 27 –

Oxygen Sensors

Oxygen Oxygen

Nitrogen

Oxygen

Water vapor

In order to determine the concentration in ppm (mg/l) from the partial pressure measured, we must know the temperature, the air pressure and the solubility (usually in a table depending on temperature). In most devices the solubility table for oxygen in water is built in. The compensation of air pressure is often neglected, since the diffe-rences are small. Most oxygen sensors pos-sess an internal temperature sensor . This fulfills two functions: it helps to pinpoint the right solubility from the solubility table and also to compensate the sensor signal. Thus the temperature-dependent nature of oxygen diffusion is taken into consideration by the membrane. 1 ppb = 0.001 ppm

Salt effectThe solubiity of oxygen in water is affected by other substances. Salts reduce solubility, organic additives like alcohol increase solu-bility. These differences are not measurable with an oxygen sensor since the partial pressure of these additives is independent. The salt effect must be sought by means of other measurement methods for a more precise evaluation in ppm or mg/l.

Oxygen saturation

Particularly in applications at constant tem-perature - such as often in fermentation - the usual procedure is to use saturation as a measure of oxygen content. Calibration is very easy where the sensor is in in humid air or in air-saturated solution and the device is set to 100%. The value may however exceed 100% if the pressure increases. This is often the case when the oxygen sensor is fitted into a closed vessel or a pipe. A measurement value of, say, 130% saturation is therefore quite correct, since the partial pressure does in fact increase with a rise in pressure.

Basic concepts

Partial pressureOxygen sensors actually measure the partial pressure pO2 of oxygen. The sensor signal is directly proportional to the pO2. Partial pressure is not a customary unit, since concentrations of matter are mostly given in weight per volume (mg/l). Because of the compressible nature of gas mixtures such as air, concentrations per volume do not make sense. The content of a gas com-ponent is therefore given as a part of the total pressure.

Doubling of partial pressure is correctly shown by the oxygen sensor.

Effect of air humidityThe amount of water vapor that air can hold is correlated to temperature. At 20oC the maximum water vapor pressure is 23 mbar (corresponds to 100% humidity or to a sen-sor immersed in air saturated water). The partial pressure of oxygen in this situation is pO2 = 205 mbar.

If the sensor is calibrated in dry air at 20oC versus water saturated air the calibration error is about 2.5%. This error quickly grows once the temperature increases. At 82oC an error of 100% will arise if the sensor was calibrated in dry air versus air containing 100% humidity.

The 50% reduction of oxygen partial pressure is correctly measured by the sensor.

Oxygen partial pressure pO2 in a solutionWater can absorb a certain amount of air. At high temperatures gas solubility is weaker, something that is apparent from bubble formation when water is heated. Equilibrium is reached when the particular partial pressures in the solution and in the gas phase (mainly air) are identical to one another. Water saturated with air and air saturated with water exhibit identical par-tial pressures for oxygen and other gases. The oxygen sensor therefore displays the same value in both phases.

Concentration of oxygen in soluti-on in ppm, ppb or mg/l

The solubility of oxygen in water decreases as temperature rises. Furthermore, solubility is proportional to air pressure:

Oxygen Air pressure

15°C 9.76 mg/l 1013 hPa20°C 8.84 mg/l 1013 hPa25°C 8.11 mg/l 1013 hPa25°C 7.61 mg/l 950 hPa

Example 1: Air with 21% oxygen, 78% nitrogen and 1% other gases

Nitrogen

Nitrogen

Air is

compressed

Total pressure 1000 mbar pO2 = 210 mbar

Example 2 : When dissolved oxygen is measured in water it is essential that the water vapor partial pressure be taken into account. At 82oC the water vapor partial pressure at 100% humidity is 500 mbar.

Total pressure: 1000 mbar

Water vapor pressure at 82oC: 500 mbar

Percent oxygen: 21%

pO2: 105 mbar

(1000 - 500) mbar * 21% = 105 mbar pO2

Total pressure 2000 mbarpO2 = 420 mbar

Page 28: Process Sensors Hamilton

– 28 –

OXY

FERM

XL

a

O

P

VPT82/D4 T82/D4

OXY

FERM

FDA

OXY

FERM

VP

Oxygen Sensors

OXYFERM FDAOXYFERM VPOXYFERM XL

O2: 10 ppb to saturation or

0.1% - 200% of air oxygen

0 - 130 °C; max. 4 bar

TC: 22 kOhm NTC

O2: 40 ppb to saturation

0 - 60 °C, max. 4 bar

TC: 22 kOhm NTC

Maintenance-free

OXYSENS

• First maintenance-free DO sensor on the market; no changing of membrane or electrolyte required

• Developed for use in water, waste water, swimming pools, in fish farms and composting facilities

• Insensitive to soiling

• Almost flow-independent

• OXYSENS has a built-in 22 kOhm NTC for temperature compensation

• Very short polarization and response times

• 5 m fixed cable, VP head only on request.

• 12 mm stainless steel shaft, 120 mm shaft length and PG 13.5 thread

• Suitable for steam sterilization, autoclaving and CIP

• Shaft and membrane have their own serial and melt numbers

• Sanitary feature: the silicon membrane seals without a gap to steel membrane body (no additional o-ring)

• Little drift, fast response, short polarization time

• Thanks to a longer service cycle,reduced operating costs

• OXYFERM FDA is shipped with a replacement FDA membrane body

• Replacing the inner body is child‘s play

• Material and test certificate by series

• Unique feature: upside-down insertion is possible when using OXYLYTE USD electrolyte. This is very useful for measurements in nearly empty tanks/containers.

• 12 mm or 25 mm (XL version) shaft diameter

• With XL option, the o-ring position OP can be optimally matched to the weld-in socket from 22 to 55 mm. Please state the OP you want when ordering. Example: Order no. 237175-50 for OP = 50 mm (Sartorius-B.Braun safety sockets) or 237175-25 for standard sockets 237202.

• A selection of membrane materials (Standard, CIP and FDA membrane) and a selection of different membrane body shapes, with a protective edge or rounded (preferred in the case of insertion through the lid from above, so as to prevent gas bubbles collecting) are all available.

OXYFERM VP 120

OXYFERM FDA 120*

OXYFERM FDA 160*

OXYFERM VP 225

OXYFERM FDA 225*

OXYFERM VP 325

OXYFERM FDA 325*

OXYFERM FDA 425*

OXYFERM XL (a = 56 mm)

* includes an extra membrane

237 400

237 450

237 455

237 401

237 452

237 402

237 453

237 454

237 175-OP

OXYSENS 120 237 150

Name Order No.Name Order No.

OPmin = 22 mm OPmax = 55 mmPlease specify desired o-ring position OP in your order!

Accessories:

OXYFERM MEMBRANE KIT

MEMBRANE KIT CIP

MEMBRANE KIT FDA

OXYLYTE 50 mL

OXYLYTE USD 50 mL

Replacement Cathode Oxyferm

FLEXIFIT BIO (p. 33)

RETRACTOFIT BIO (p. 37)

Connecting cable (p. 32)

237 123

237 126

237 140

237 118

237 136

237 306

Simple cathode replacement:

Remove the old cathode assembly with a pull and insert the new assembly!

Page 29: Process Sensors Hamilton

– 29 –

Oxygen Sensors

OXYGOLD GDissolved oxygen sensor for general use in trace measurement

O2: 1 ppb to saturation or

0.02% - 200% of air oxygen

0 - 130 °C, max. 12 bar

TC: 22 kOhm NTC

OXYGOLD BDissolved oxygen sensor for measurements in media containing acidic gases CO2, in beer

O2: 8 ppb to saturation or

0.1% - 200% of air oxygen

0 - 100 °C, max. 12 bar

TC: 22 kOhm NTC

Replacement Membranes and Polarization Modules

As above, but with a special membrane for intensive CIP cleaning

Membrane Kit CIP

OXYGOLD Membrane Kit

3 OXYGOLD membranes, spare o-ring, pipette. Electrolyte must be ordered separately.

Membrane Kit FDA

FDA membrane material and rounded design to prevent accumulation of gas bubbles

OXYFERM Membrane Kit

3 membrane bodies, Oxylyte, pipette, spare o-ring, polishing strip

Polarization modules

These prepare replace-ment sensors not con-nected to an amplifier for immediate use

• Developed for use in power plants or chemical, pharmaceutical and semiconductor industries

• Suitable for use at high temperatures, high pressures, during sterilization and CIP

• Easy to maintain

• Inner body can be replaced by user

• Little flow sensitivity

• Fast response time:

t98% < 60 sec.

• Materials and inspection certificate

• 12 mm shaft diameter,VP plug

• Absolutely no cross-sensitivity to CO2

• Developed for use in brewing, Cola, fruit-juice, sparkling wine and special chemical processes

• Pressure and CIP stable

• Easy to maintain

• Inner body can be replaced by user

• Shortest response time on the market from air to pure

CO2: t98% < 60 sec

• Materials and inspection certificate

• Works cleanly with the same polarization voltages in calibration and measurement operation. So you don‘t get the usual false measurement values when measuring beer or the like

• 12 mm shaft, VP plug

Accessories:

OXYGOLD MEMBRANE-KIT

OXYLYTE G 50 mL

POLARIZATION MODULE G

Replacement Cathode OxyGold G

FLEXIFIT BIO (p. 33)

RETRACTOFIT BIO (p. 37)

Connecting cable (p. 32)

237 135

237 139

237 350

237 427

237 135

237 123

237 126

237 140

237 370

237 350

237 360

237 139

237 138

237 118

237 136

OXYGOLD MEMBRANE KIT

OXYFERM MEMBRANE KIT

MEMBRANE KIT CIP

MEMBRANE KIT FDA

POLARIZATION MODULE T

for OXYFERM /~FDA/~XL

POLARIZATION MODULE G

for OXYFERM VP, OXYGOLD G

POLARIZATION MODULE B

for OXYGOLD B

Accessories:

OXYGOLD OXYLYTE G 50 mL

OXYGOLD OXYLYTE B 50 mL

OXYFERM OXYLYTE 50 mL

OXYLYTE USD 50 mL

Name Order No. Name Order No. Name Order No. OXYGOLD G 120

plus OXYLYTE G

OXYGOLD G 225

plus OXYLYTE G

237 395

237 139

237 396

237 139

OXYGOLD B 120

plus OXYLYTE B

OXYGOLD B 225

plus OXYLYTE B

237 180

237 138

237 185

237 138

Accessories:

OXYGOLD MEMBRANE-KIT

OXYLYTE B 50 mL

POLARIZATION MODULE B

Replacement Cathode OxyGold B

FLEXIFIT BIO (p. 33)

RETRACTOFIT BIO (p. 37)

Connecting cable (p. 32)

237 135

237 138

237 360

237 437

Page 30: Process Sensors Hamilton

– 30 –

Conductivity and 6-in-1 Sensors

1.0 - 200 µS/cm or

0.1 - 200‘000 µS/cm linearized

Cell constant: c = 0.4/cm

Max. 20 bar at 130 °C

Temperature sensor: Pt1000

CONDUCELL 2UP2-Pole Conductivity Sensorsfor non-critical applications

• Steam-sterilizable and autoclavable, CIP

• 2 large platinum rings

• In contact with media: glass, platinum, FDA-EPDM

• Note: 2-pole cells do not behave linearly - especially in the case of high conductivity values. Therefore, linearization with the measurement device used is recommended. This is not needed in the case of a target value check.

CONDUCELL 2UP-PG-120

Accessories:

Conductivity standards (p. 8)

FLEXIFIT BIO (p. 33)

Connecting cable (p. 32)

237 600

Name Order No. Name Order No.Name Order No.

pH: 0...14

Temperature: Pt1000 and

Redox: +/- 2000 mV and/or

Conductivity: c = 0.4/cm and/or

Liquid earth - platinum contact

Built-in reference for pH/Redox

JACOTRODE VP6-in-1 Sensors

• Steam-sterilizable and autoclavable, limited CIP use

• 2 large platinum rings for Redox, conductivity and liquid earth

• Sanitary feature: only one o-ring for several parameters

• EVEREF-F cartridge and SKYLYTE Electrolyte

• HP-COATRAMIC diaphragm prevents protein deposits

• Max. 4 bar at 130 °C

• High-tech made by HAMILTON!

JACOTRODE VP 120

JACOTRODE VP 225

Accessories:

Storage solution 500 mL

FLEXIFIT BIO (p. 33)

RETRACTOFIT BIO (p. 307)

Connecting cable (p. 32)

238 442

238 443

238 931

CONDUCELL 4USF-PGCONDUCELL 4UHF-PGCONDUCELL 4UTF-PG4-Pole Conductivity Sensors

CONDUCELL 4USF-PG 120

CONDUCELL 4UHF-PG 120

CONDUCELL 4UTF-PG 120

CONDUCELL 4USF-VV

CONDUCELL 4USF-BC

CONDUCELL 4USF-AF 200

CONDUCELL 4USF-DF 80

Accessories:

Conductivity standards (p. 8)

FLEXIFIT BIO (p. 33)

Connecting cable (p. 32)

237 620

237 627

237 630

237 640

237 650

on

request

1 - 500‘000 µS/cm

Cell constant: c = 0.36/cm

Max. 10 bar / 150 °C; 20 bar / 135°C

T: -20 - 150 °C

Temperature sensor: Pt1000

• Very good linearity over 6 decades. Specially for situations with sharp variations in conductivity

• Suitable for steam sterilization, autoclaving and CIP

• Certificates confirm: all parts in contact with media are FDA-compliant: PEEK, stainless steel DIN 1.4435 (4USF types), EPDM

• Sanitary: surface quality is N5 (0.4 μm), electro-polished, sensor is very easy to clean due to the forward-facing, flush arrangement of electrodes

• Can be inserted in many standard armatures. Around the tip of the electrode there should be a space of 10 mm.

Page 31: Process Sensors Hamilton

– 31 –

237

750

237

700

237

760

Example: CONDUCELL 4USF-VV

Conductivity Sensors

0.1 - 500‘000 µS/cm

Cell constant: c = 0.147/cm

Max. 6 bar at 135 °C

T: -20 - 135 °C

Temperature sensor: Pt1000

CONDUCELL 4US4-Pole Conductivity Cells

• Very good linearity over 6 decades. Specially for situations with widevariations in conductivity

• Suitable for steam sterilization, autoclaving and CIP

• Certificates confirm: all parts in contact with media are FDA-compliant: PEEK, stainless steel DIN 1.4435, EPDM

• Sanitary: surface quality is N5 (0.4 μm), electro-polished, sensor is easy to clean

• Fixed cable 5 m

237 700

237 710

237 750

237 760

CONDUCELL 4US-G125-62/25

CONDUCELL 4US-G125-85/48

CONDUCELL 4US-T150-50

CONDUCELL 4US-T150-100

Example: 4US-G125-62/25 4: 4-PoleU: Undefined/open field S: Stainless steel; H: Hastelloy C; T: Titanium; P: Pt Electrodes F: Flat electrode arrangement for easy cleaningG125: G1.25“; T150: Triclamp 1.5“ connection; PG: PG13.562: 62 mm shaft length/25: (optional) O-ring, seals at 25 mm

Accessories:

Conductivity standards (p. 8)

Name Order No.Unique LinearityMeasurements carried out with a process-conductivity converter

Reference Conductivity [µS/cm]

Mea

sure

men

t val

ues

read

[µS/

cm]

(1-p

oint

cal

ibra

tion

at 1

413

µS/c

m)

Description same as CONDUCELL 4USF-PG, but

there are different process connections:

VV - Tuchenhagen Varivent DN50/60

BC - Neumo Bioconnect

AF 200 - ANSI flange 2.00“

DF 80 - DIN flange DN 80 mm; ask for others!

CONDUCELL 4USF-VVCONDUCELL 4USF-BCCONDUCELL 4USF-AF 200CONDUCELL 4USF-DF 80

Other sensor types on request!

Page 32: Process Sensors Hamilton

– 32 –

Connecting Cables for Sensors

Für Sensoren mit Standard-(S7)-Steckkopf. Messgeräteseite ohne Stecker (freies Ende) Bestell-Nr.Länge: 1 m, Durchmesser: 5 mm 355 072Länge: 5 m, Durchmesser: 5 mm 355 066Länge: 10 m, Durchmesser: 5 mm 355 080

For sensors with standard (S7) plug. Measurement device side no plug (free end) Order No.Length: 1 m, Diameter: 5 mm 355 072Length: 5 m, Diameter: 5 mm 355 066Length: 10 m, Diameter: 5 mm 355 080

Für Sensoren mit Standard-(S7)-Steckkopf. Messgeräteseite mit BNC-Stecker Bestell-Nr.Length: 1 m, Diameter: 3 mm 355 043Length: 3 m, Diameter: 3 mm 355 057Length: 5 m, Diameter: 3 mm 355 056

For sensors with standard (S7) plug. Measurement device side has BNC connector Order No.

Für Sensoren mit Standard-(S7)-Steckkopf. Messgeräteseite mit DIN-Stecker Bestell-Nr.Länge: 1 m, Durchmesser: 3 mm 355 045Länge: 3 m, Durchmesser: 3 mm 355 059Länge: 5 m, Durchmesser: 3 mm 355 058

For sensors with standard (S7) plug. Measurement device side has DIN plug Order No.Length: 1 m, Diameter: 3 mm 355 045Length: 3 m, Diameter: 3 mm 355 059Length: 5 m, Diameter: 3 mm 355 058

Für Sensoren mit VP 6.0 oder 8.0-Steckkopf. 8-poliges, flexibles, besonders rauscharmes Doppelkoaxialkabel. (freies Ende) Bestell-Nr.Länge: 1 m, Durchmesser: 7,5 mm 355 108Länge: 3 m, Durchmesser: 7,5 mm 355 109Länge: 5 m, Durchmesser: 7,5 mm 355 110Länge: 10 m, Durchmesser: 7,5 mm 355 111Länge: 20 m, Durchmesser: 7,5 mm 355 112

For sensors with VP 6.0 or 8.0 plug. 8-pole, flexible, double coaxial cable, particularly low-noise (free end) Order No.Length: 1 m, Diameter: 7,5 mm 355 108Length: 3 m, Diameter: 7,5 mm 355 109Length: 5 m, Diameter: 7,5 mm 355 110Length: 10 m, Diameter: 7,5 mm 355 111Length: 20 m, Diameter: 7,5 mm 355 112

Für OXYFERM Sensoren ohne „VP“ Steckkopf. Messgeräteseite ohne Stecker (freies Ende) Bestell-Nr.Länge: 1 m, Durchmesser: 5 mm 355 087Länge: 3 m, Durchmesser: 5 mm 355 088Länge: 5 m, Durchmesser: 5 mm 355 089

For OXYFERM sensors without VP plug. Measurement device side has no plug (free end) Order No.Length: 1 m, Diameter: 5 mm 355 087Length: 3 m, Diameter: 5 mm 355 088Length: 5 m, Diameter: 5 mm 355 089

Für Sensoren mit K8-Steckkopf. Messgeräteseite ohne Stecker (freies Ende) Bestell-Nr.Länge: 1 m, Durchmesser: 5 mm Länge: 3 m, Durchmesser: 5 mm Länge: 5 m, Durchmesser: 5 mm Länge: 10 m, Durchmesser: 5 mm

For sensors with K8 plug. Measurement device side has no plug (free end) Order No.Length: 1 m, Diameter: 5 mm 355 153Length: 3 m, Diameter: 5 mm 355 154Length: 5 m, Diameter: 5 mm 355 155Length: 10 m, Diameter: 5 mm 355 156

Page 33: Process Sensors Hamilton

– 33 –

OP

Standard Armatures

FLEXIFIT TC FLEXIFIT BIO FLEXIFIT VV

The FLEXIFIT TC is designed for mounting on TriClamp process connections. The materials used are stainless steel DIN 1.4435 (SS 316) and FDA approved EPDM o-rings. Steam sterilization, autoclavation and CIP cleaning are possible with the sanitary design. The short immersion depth makes this armature perfect for small flow-through cells. Maintenance-free sensors with a standard 12 x 120 mm design and PG 13.5 thread fit perfectly.

The FLEXIFIT BIO armature provides the best of both worlds. It is the right compromise between good sensor protection (with 3 protection rods) and good sanitary design (easy cleaning and no sensor clogging). The FLEXIFIT BIO is manufactured from stainless steel DIN 1.4435 (SS 316). The surface quality is N5 (Ra = 0.4 µm), electro-polished. The EPDM o-rings are FDA-approved. The armature comes with a material certificate. It is SIP, autoclavable, and CIP compatible.

The FLEXIFIT VV is an armature suitable for Tuchenhagen VARIVENT sanitary process connections (DN40/DN50 or 2“/2.5“). It fits industrial sensors with a standard 12 x 120 mm design and PG 13.5 thread. .FLEXIFIT VV-O is the upright (0°) version, whereby the sensor is fitted perpendicular to the process connection. The 15° version FLEXIFIT VV-15 enables positioning of the sensor in relation to the flow.

FLEXIFIT BIO

(o-ring seals at OP;

22 mm < OP < 55 mm)

Accessories:

Weld-in socket (p. 40)

FDA service kit

237 331-OP

237 338

Name Order No.

FLEXIFIT TC150-33 237 341

Name Order No.

FLEXIFIT VV-0

FLEXIFIT VV-15

237 344

237 345

Name Order No.

Page 34: Process Sensors Hamilton

– 34 –

Standard Armatures

FLEXIFLOW SL 10

The FLEXIFLOW Armature is a flow-through armature. It can be used in all cases where pH or oxygen must be reliably measured in ion-weak media including coolant piping in power generating stations.The sample is fed into the armature from from the bottom at a low flow speed, and out of the armature again at the side. Dependable Swagelok connectors serve as process connections for 10 mm diameter pipe. A groove cut into the FLEXIFLOW allows it to be attached anywhere with commercially available screws, for example to a plate. Materials: DIN 1.4435 and o-rings of FDA-EPDM.Suitable sensors: PG 13.5; 12 x 120 mm

FLANGE-ADAPTER

Accessories:

Flow-through cell (p. 40)

Kalrez Kit

Name Order No.

FLEXIFLOW SL 10 237 340

Name Order No.

The FLANGE-ADAPTER allows a MASTERFIT 120 to be mounted on an ANSI B 16.5 - 1-1/2" flange. The materials wetted by the media are PTFE and KALREZ™. An example installation would include a CHEMOTRODE sensor with a shaft length of 150mm, such as the CHEMOTRODE BRIDGE 150, pressurized in the MASTERFIT 120. A combination like this is often able to achieve a long lifetime even in highly aggressive process media. The FLANGE-ADAPTER fits the PFA Flange through-flow Cell (see page 40)

Flange adapter for Masterfit FLEXIFLANGE

The FLEXIFLANGE is the FLEXIFIT version for ANSI B 16.5 1-1/2" flange. The materials wetted by the media are PTFE and KALREZ™. Maintenance-free process electrodes with a shaft of 12 mm in diameter and 120 mm length in combination with the FLEXIFLANGE armature provide a robust process solution for extremely corrosive process media. The FLEXIFLANGE fits the PFA Flange flow-through cell (see page 40).

FLEXIFLANGE

Accessories:

Flow-through cell (p. 40)

Kalrez Kit

Name Order No.

237 320

237 930

237 319

237 910

237 930

237 319

Page 35: Process Sensors Hamilton

– 35 –

OP

Pressurizable Armatures

MASTERFIT

Suitable for applications where high accuracy or long-term stability is required in conjunction with liquid electrolyte electrodes. Such electrodes must be pressurized to ensure flow of the electrolyte solution. The MASTERFIT armature allows electrodes to be mounted on pipe work or tanks with a weld-in socket. Large windows allow visual inspection of the electrolyte level in the installed electrode. The manometer integrated into the housing is protected against physical damage. The armature closure mechanism is fitted with a tension lever that allows a slow release of the pressure

in the armature in the event it needs to be opened. This prevents the armature from being opened under pressure. The tension lever also makes it very easy to unscrew the housing and remove the sensor.

Advantages:

• Sealing feature prevents loss of pressure caused by soiling

• Pressure reduction on disassembly

• O-ring position selectable at time of order without extra charge

MASTERFIT 120

MASTERFIT 150

MASTERFIT 200

Pressure connector

Service Kit Masterfit

Kalrez Kit Masterfit

237 200-OP

237 225-OP

237 235-OP

237 252

237 229

237 319

Name Order No.

The pressure connector enables a fixed connection to a compressed-air line

Please specify desired o-ring position OP in your order!

Page 36: Process Sensors Hamilton

– 36 –

RETR

ACTO

FIT

RETR

ACTO

FIT

PEEK

Retractable Armatures

RETRACTOFIT, RETRACTOFIT PEEK

The HAMILTON RETRACTOFIT is an ideal armature for industrial applications. The armature allows the user to install maintenance-free electrodes in critical processes. The main advantage of this design is that the sensor can be withdrawn while the process is running (i.e. for cleaning, calibration or even to replace the electrode), without interrupting the process. The design allows the use of sensors with 210 to 225 mm shaft length and a PG 13.5 thread, e.g. electrodes such as the EASYFERM PLUS VP 225, MECOTRODE 225 and OXYGOLD G 225. The armature is very easy to use and maintain. Only one press of the red button is needed to move the electrode into or out of the process. All o-rings are easily replaced without special tools. An integral safety mechanism prevents the armature from being inserted into the sample without an electrode installed. This prevents an open connection between the inside of the process vessel and the external environment. In the retracted position, the electrode is retained in a chamber where it can be kept moist, cleaned and even calibrated. This can all be done without process interruption or disassembly of the armature. Two tube

connectors allow access to the rinsing chamber.Two accessories are available for the RETRACTOFIT. A shortened insertion tube that allows use of the armature in narrow-bore pipes for which the standard insertion tube is too long. A closed insertion tube converts the RETRACTOFIT into a sampling system for diverse applications. Both accessories can easily be exchanged for the standard insertion tube using only gentle hand pressure.

The RETRACTOFIT BIO on page 37 is the sanitary designed version for biotechnology and food applications.

Advantages:

• One-hand operation

• Insertion is only possible with an

electrode installed

• Electrode cannot be removed when in

measurement position

• Visual check of o-rings

• Longer sensor life due to 225 mm

sensor length

RETRACTOFIT PEEK:All steel parts constantly exposed to the process are replaced with PEEK. This allows the holder to be used with highly corrosive media providing the calibration chamber is thoroughly rinsed after retraction.

RETRACTOFIT

RETRACTOFIT PEEK 25

Accessories:

Weld-in socket (p. 40)

Service Kit Retractofit

Kalrez Kit Retractofit

237 240

237 490

237 239

237 339

Name Order No.

Page 37: Process Sensors Hamilton

– 37 –

OP

OP

Retractable Armature, Sanitary Version

RETRACTOFIT BIO

The HAMILTON RETRACTOFIT BIO is an armature designed for applications where sanitary concerns are critical. The armature is steam-sterilizable and autoclavable. The stainless steel DIN 1.4435 (SS 316) and the FDA-approved EPDM o-rings withstand typical CIP cleaning.The main advantage of this armature is that the sensor can be withdrawn while the process is running (i.e. for cleaning, calibration or even to replace the electrode), without interrupting the process. The design allows the use of sensors with 210 to 225 mm shaft length and a PG 13.5 thread, e.g. electrodes such as the HAMILTON POLYCLAVE 225, POLILYTE HTVP 225, EASYFERM PLUS VP 225 and OXYFERM 225. The armature is very easy to use and maintain. Only one press of the red button is needed to move the electrode into or out of the process. All o-rings are easily replaced without special tools. An integral safety mechanism prevents the armature from being inserted into the sample without an electrode installed. This prevents the risk of open connection between the inside of the process vessel and the external environment. Two leakage detection openings indicate seal

failures during operation.In the retracted position, the electrode is retained in a chamber where it can be kept moist, cleaned and even calibrated. This can all be done without process interruption or disassembly of the armature. Two tube connectors allow access to the rinsing chamber.

The RETRACTOFIT on page 36 is designed for applications in the chemical and waste water industry.

ATTENTION: Check with your dealer for the right o-ring position or weld-in socket! (o-ring seals at 55 mm; other distances on request.).

Advantages:

• Autoclavable• One-hand operation• Various leakage indicators• Longer sensor life due to 225 mm

sensor length• Insertion is only possible with an

electrode installed• No removal of sensor when in

measurement position

RETRACTOFIT BIO 55

(o-ring seals at OP = 55mm)

RETRACTOFIT BIO 25

(o-ring seals at OP = 25mm)

Accessories:

FDA Service Kit

237 440

237 480

237 338

Name Order No.

Page 38: Process Sensors Hamilton

– 38 –

Pressurizable Retractable Armature

RETRACTOMASTER

Suitable for applications in which liquid electrolyte electrodes must be used and cleaning or recalibration during the process is desirable. The RETRACTOMASTER armature allows these electrodes to be mounted on a tank with a weld-in socket. As with the MASTERFIT, there are no awkward flat seals for sealing the armature. Large windows allow visual inspection of the electrolyte level inside the electrode. The manometer integrated into the housing and the other specifications match that of the MASTERFIT armature.

The armature is very easy to use and maintain. Only one press of the red button is needed to move the electrode into or out of the process. All o-rings are easily replaced without special tools. In the retracted position, the electrode is retained in a chamber where it can be

kept moist, cleaned and even calibrated. This can all be done without process interruption or disassembly of the armature. Two tube connectors allow access to the rinsing chamber.Note: Use CHEMOTRODE type sensors with a shaft length of 250 mm

Advantages:

• One-hand operation• Visual check of the most used seals

RETRACTOMASTER

Accessories:

Pressure connector

Weld-in socket (p. 40)

Service Kit

Kalrez Kit

237 250

237 252

237 239

237 339

Name Order No.

The pressure connector enables a fixed connection to a compressed-air line

Page 39: Process Sensors Hamilton

– 39 –

Electric Retractable Armature

or to check other systems (such as pumps, magnetic valves). The armature is shipped with a 5 m fixed cable.

Advantages:

• 24 VDC operation

• Simple fitting

• Easily controlled by SPS for example

• Longer sensor life due to 225 mm sensor length

RETRACTOMATIC

Accessories:

Service Kit

Kalrez Kit

237 260

237 290

237 339

Name Order No.

RETRACTOMATIC

This armature has everything. The RETRACTOMATIC is the motorized version of the RETRACTOFIT described on page 36. Use of an electrically driven system allows maintenance, servicing and calibration tasks to be largely automated, it is also easier to use than existing pneumatic systems. The robust housing and the powerful 24 VDC drive easily handle the most severe process conditions. The RETRACTOMATIC can be controlled in a variety of ways from a simple time switch to a computerized system like SPS. At the same time the user has available 2 limit switches. These contacts can be used either for the display of electrode position (inserted/retracted)

Page 40: Process Sensors Hamilton

– 40 –

Immersion set Order No.

Covers and protects 120 mm sensors such as the oxygen sensor OXYSENS during immersion in flowing water or aeration tanks. Weight ca. 300 g

237 158

25 mm weld-in socket with G 1-1/4“ thread Order No.

This weld-in socket allows armatures and sensors with a G 1-1/4“ thread to be inserted in a steel pipe or container. This special design ensures that the inner diameter is not affected by the welding process, so that there is no need for reworking and filing of the material after welding. The ends of these weld-in sockets are at an angle of 15° and they can be fitted universally. Suitable for sealing at 25 mm (OP=25mm). Other dimensions on request!

237 202

Plugs for weld-in sockets Order No.

Enables weld-in sockets to to be capped when the armature is removed. Seals at 25 mm. Other dimensions on request!

237 230

Flange flow-through cell PFA Order No.

PFA-coated steel T-joint with flange connections (ANSI B 16.5: 2x2“ and 1 x 1 -1/2“) for fitting the FLEXIFLANGE or FLANGE-ADAPTER for the MASTERFIT Armature. Other dimensions on request!

237 930

Flow-through cell PEEK TC Order No.

The flow-through cell made of FDA-approved PEEK facilitates insertion of CONDUCELL 4US-T150-50 in pipework at temperatures up to 140°C.

237 931

Accessories for Armatures

Page 41: Process Sensors Hamilton

– 41 –

R

Notes

Page 42: Process Sensors Hamilton

– 42 –

Technical Data: Armatures

RETRACTOFIT RETRACTOMATIC MASTERFIT RETRACTOMASTER FLEXIFLANGE

Process connection G 1 1/4" G 1-1/4" G 1-1/4" G 1-1/4" ANSI B16,5

Min. total length 420 mm 420 mm varies (s.S.35) 630 mm 290 mm

Max. total length 450 mm 450 mm varies (s.S.35) 660 mm 290 mm

Max. diameter 70 mm 160 mm 60 mm 70 mm 150 mm

Sensor insertion depth 70 mm 70 mm 70 mm 70 mm 55 mm

Armature insertion depth

105 mm 105 mm 80 mm 105 mm 34 mm

Material SS 316/DIN 1.4571 SS 316/DIN 1.4571 SS 316L/DIN 1.4435 SS 316/DIN 1.4571 PTFE

Standard seals VITON VITON VITON VITON KALREZ

Temperature range -10 to +130°C -10 to +130°C -10 to +130°C -10 to +130°C -10 to +130°C

Max. pressure 6 bar 6 bar 6 bar 6 bar 6 bar

Weight 1350 g 3400 g 1400 g 2150 g 850 g

For electrodes with 12 mm PG 13.5 12 mm PG 13.5 30 mm standard 30 mm standard 12 mm PG 13.5

Electrode shaft length a = 225 mm a = 225 mm various a = 250 mm a = 120 mm

Catalog page 36 39 35 38 34

FLEXIFLOW SL 10 RETRACTOFIT BIO FLEXIFIT VV FLEXIFIT TC FLEXIFIT BIO

Process connection Swagelog 10 mm G 1-1/4" Varivent TriClamp 1.5" G 1-1/4"

Min. total length 175 mm 366 mm 100 mm 133 mm 133 mm

Max. total length 175 mm 443 mm 100 mm 133 mm 133 mm

Max. diameter 65 mm 70 mm 85 mm 50.5 mm 50 mm

Sensor insertion depth — 70 mm 30 mm 32 mm various

Armature insertion — 132 mm 2 mm 33 mm various

Material SS 316L/DIN 1.4435 SS 316L/DIN 1.4435 SS 316L/DIN 1.4435 SS 316L/DIN 1.4435 SS 316L/DIN 1.4435

Standard seals FDA-EPDM FDA-EPDM FDA-EPDM FDA-EPDM FDA-EPDM

Temperature range -10 to+130°C -10 to +135°C -10 to +135°C -10 to +135°C -10 to +135°C

Max. pressure 16 bar 6 bar 6 bar 6 bar 6 bar

Weight 1200 g 1840 g 950 g 490 g 490 g

For electrodes with 12 mm PG 13.5 12 mm PG 13.5 12 mm PG 13.5 12 mm PG 13.5 12 mm PG 13.5

Electrode shaft length a = 120 mm a = 225 mm a = 120 mm a = 120 mm a = 120 mm

Catalog page 34 37 33 33 33

Technical Data: Oxygen Sensors

Page 43: Process Sensors Hamilton

– 43 –

Technical Data: Oxygen Sensors

OXYGOLD G OXYGOLD B OXYFERM ... OXYFERM XL OXYSENS

Measurement range 1 ppb - 40 ppm 8 ppb - 40 ppm 10 ppb - 40 ppm 10 ppb - 40 ppm 40 ppb - 40 ppm

Polarization voltage -670 +/- 50 mV 0 mV -670 +/- 50 mV -670 +/- 50 mV -670 +/- 50 mV

Signal in air at 25°C 180 - 400 nA 180 - 400 nA 40 - 80 nA 40 - 80 nA 40 - 80 nA

Response time t98% 30 - 60 sec. 30 - 60 sec. 30 - 60 sec. 30 - 60 sec. 60 sec.

Minimum required flow 0.1 m/sec. 0.1 m/sec. 0.02 m/sec. 0.02 m/sec. 0.02 m/sec.

Temperature range 0 - 130°C 0 - 100°C 0 - 130°C 0 - 130°C 0 - 60°C

Pressure range (relative) 0 - 12 bar 0 - 12 bar 0 - 4 bar 0 - 4 bar 0 - 4 bar

Drift at 25°C < 1% / week < 2% / week < 2% / week < 2% / week < 2% / week

Fitting PG 13.5 thread PG 13.5 thread PG 13.5 thread G 1 1/4" thread PG 13.5 thread

Electrical connection VP 6.0 VP 6.0 VP or T82 / D4 T82 / D4 Fixed cable 5 m

Temperature sensor NTC 22kOhm NTC 22kOhm NTC 22kOhm NTC 22kOhm NTC 22kOhm

Standard sealings FDA-EPDM FDA-EPDM FDA-EPDM FDA-EPDM FDA-EPDM

Shaft material DIN 1.4435 DIN 1.4435 DIN 1.4435 DIN 1.4435 DIN 1.4435

Shaft diameter 12 mm 12 mm 12 mm 25 mm 12 mm

Shaft length a 120 or 215 mm 120 or 215 mm varies varies 120 mm

Catalog page 29 29 28 28 28

Page 44: Process Sensors Hamilton

– 44 –

Technical Data: pH Sensors

pH or Redox Sensor Shaft material pH glass type pH glass

resistance

Nominal

Measurement

range

Reference

system

Reference

electrolyte

Number of

Diaphragms

Diaphragm type Sample: Min.

Conductivity

Temperature

range

Pressure

range

Shaft

length (a)

Electrode

head

Catalog page

CHEMOTRODE Glass PHI moderate 0...14 EVEREF-F 3M KCl-LR 3 HP ceramic 50 µS/cm 0...130°C < 6 bar various Standard 14, 20

CHEMOTRODE BRIDGE Glass PHI moderate 0...14 EVEREF-B SKYLYTE 1 Platinum 250 µS/cm 0...130°C < 6 bar various various 20, 24

CHEMOTRODE ORP Glass Platinum — +/- 2000 mV EVEREF-F 3M KCl-LR 3 HP ceramic 50 µS/cm 0...130°C < 6 bar various Standard 14, 20

CHEMOTRODE P Glass PHI moderate 0...14 EVEREF-F PROTELYTE 3 HP ceramic 50 µS/cm 0...130°C < 6 bar various Standard 14, 20

CLARYTRODE Glass HF moderate 0...14 EVEREF-L POLISOLVE 2 SINGLE PORE 5 µS/cm -10...100°C < 6 bar 120 mm PG 13.5 19, 23

DELTATRODE Glass PHI moderate 0...14 2. pH Half-cell DELTALYTE 1 HP ceramic 50 µS/cm 0...60°C < 2 bar various PG 13.5 21, 24

EASYCONTROL Glass V low 0...14 Ag/AgCl Gel 1 Ceramic 50 µS/cm 0...60°C < 2 bar various PG 13.5 22

EASYCONTROL ORP Glass Platinum — +/- 2000 mV Ag/AgCl Gel 1 Ceramic 50 µS/cm 0...60°C < 2 bar various PG 13.5 22

EASYFERM Glass PHI moderate 0...14 EVEREF-F SKYLYTE 3 COATRAMIC *** 50 µS/cm 0...130°C < 4 bar various various 13

EASYFERM PLUS Glass PHI moderat 0...14 EVEREF-F PHERMLYTE 1 HP-COATRAMIC 100 µS/cm 0...135°C < 6 bar various various 13, 18

FERMOTRODE Glass PHI moderate 0...14 EVEREF-F SKYLYTE 3 COATRAMIC *** 50 µS/cm 0...130°C < 4 bar various Standard 14

INCHTRODE N100F FDA PVDF HF moderate 0...14 EVEREF-L POLISOLVE 1 SINGLE PORE Ring 2 µS/cm -10...130°C < 10 bar 2 x MNPT 1“ 15, 17, 21

INCHTRODE N75F PPS - Ryton HF moderate 0...14 EVEREF-L POLISOLVE 1 SINGLE PORE Ring 2 µS/cm -10...130°C < 10 bar 2 x NPT 3/4“ 17, 21, 24

INCHTRODE N75P PPS - Ryton PHI moderate 0...14 EVEREF-L POLISOLVE 1 SINGLE PORE Ring 50 µS/cm 0...130°C < 10 bar 2 x NPT 3/4“ 21, 24

IONOTRODE Glass F very low 0...14 EVEREF 3M KCl 1 Ring, removable 0.2 µS/cm -10...40°C < 0.5 bar ** 120 mm PG 13.5 16

LIQ-GLASS PG Glass F low 1...12 EVEREF liquid 3 Ceramic 2 µS/cm -5...60°C < 2 bar 120 mm PG 13.5 16

MECOTRODE Glass H moderate 0...14 EVEREF Gel 3 HP ceramic 50 µS/cm 0...130°C < 16 bar various various 19, 23

OXYTRODE PT Glass Platinum — +/- 2000 mV EVEREF Gel 3 HP ceramic 50 µS/cm -10...130°C < 16 bar 120 mm PG 13.5 19, 23

pHeasy Glass H moderate 0...14 EVEREF-L POLISOLVE 2 SINGLE PORE 2 µS/cm 0...60°C < 6 bar various PG 13.5 17, 19, 23

pHeasy HT Glass PHI moderate 0...14 EVEREF-L POLISOLVE 2 SINGLE PORE 50 µS/cm 0...130°C < 6 bar various PG 13.5 13, 17, 19

POLILYTE HT Glass H moderate 0...14 EVEREF-L POLISOLVE 2 SINGLE PORE 2 µS/cm 0...130°C < 6 bar various various 15, 18

POLILYTE PLUS Glass H moderate 0...14 EVEREF-L POLISOLVE PLUS 2 SINGLE PORE 2 µS/cm 0...130°C < 6 bar various various 17, 18

POLILYTE PRO Glass V low 0...14 EVEREF-B POLISOLVE 1 SINGLE PORE 2 µS/cm -10...60°C < 6 bar 120 mm various 16, 22

POLILYTE PRO XP Glass V low 0...14 EVEREF-B POLISOLVE 1 SINGLE PORE 2 µS/cm -10...60°C < 50 bar 120 mm PG 13.5 16, 22

POLILYTE RX Glass Platinum — +/- 2000 mV EVEREF-B POLISOLVE 1 SINGLE PORE 5 µS/cm -10...60°C < 6 bar various PG 13.5 22

POLYCLAVE Glass PHI moderate 0...14 EVEREF-L POLISOLVE 2 SINGLE PORE 50 µS/cm 0...130°C < 6 bar various various 15

POLYPLAST PRO Plastic V moderate 0...14 Ag/AgCl POLISOLVE 1 SINGLE PORE 5 µS/cm -10...40/60°C < 6 bar 120 mm various 22

POLYPLAST PRO RX Plastic Platinum — +/- 2000 mV Ag/AgCl POLISOLVE 1 SINGLE PORE 5 µS/cm -10...40/60°C < 6 bar 120 mm various 22

* at 25°C; ** Dependent on positioning of electrolyte container; *** Not suitable for citric acid and frequent contact with hot alkali, as in CIP cleaning

Page 45: Process Sensors Hamilton

– 45 –

pH or Redox Sensor Shaft material pH glass type pH glass

resistance

Nominal

Measurement

range

Reference

system

Reference

electrolyte

Number of

Diaphragms

Diaphragm type Sample: Min.

Conductivity

Temperature

range

Pressure

range

Shaft

length (a)

Electrode

head

Catalog page

CHEMOTRODE Glass PHI moderate 0...14 EVEREF-F 3M KCl-LR 3 HP ceramic 50 µS/cm 0...130°C < 6 bar various Standard 14, 20

CHEMOTRODE BRIDGE Glass PHI moderate 0...14 EVEREF-B SKYLYTE 1 Platinum 250 µS/cm 0...130°C < 6 bar various various 20, 24

CHEMOTRODE ORP Glass Platinum — +/- 2000 mV EVEREF-F 3M KCl-LR 3 HP ceramic 50 µS/cm 0...130°C < 6 bar various Standard 14, 20

CHEMOTRODE P Glass PHI moderate 0...14 EVEREF-F PROTELYTE 3 HP ceramic 50 µS/cm 0...130°C < 6 bar various Standard 14, 20

CLARYTRODE Glass HF moderate 0...14 EVEREF-L POLISOLVE 2 SINGLE PORE 5 µS/cm -10...100°C < 6 bar 120 mm PG 13.5 19, 23

DELTATRODE Glass PHI moderate 0...14 2. pH Half-cell DELTALYTE 1 HP ceramic 50 µS/cm 0...60°C < 2 bar various PG 13.5 21, 24

EASYCONTROL Glass V low 0...14 Ag/AgCl Gel 1 Ceramic 50 µS/cm 0...60°C < 2 bar various PG 13.5 22

EASYCONTROL ORP Glass Platinum — +/- 2000 mV Ag/AgCl Gel 1 Ceramic 50 µS/cm 0...60°C < 2 bar various PG 13.5 22

EASYFERM Glass PHI moderate 0...14 EVEREF-F SKYLYTE 3 COATRAMIC *** 50 µS/cm 0...130°C < 4 bar various various 13

EASYFERM PLUS Glass PHI moderat 0...14 EVEREF-F PHERMLYTE 1 HP-COATRAMIC 100 µS/cm 0...135°C < 6 bar various various 13, 18

FERMOTRODE Glass PHI moderate 0...14 EVEREF-F SKYLYTE 3 COATRAMIC *** 50 µS/cm 0...130°C < 4 bar various Standard 14

INCHTRODE N100F FDA PVDF HF moderate 0...14 EVEREF-L POLISOLVE 1 SINGLE PORE Ring 2 µS/cm -10...130°C < 10 bar 2 x MNPT 1“ 15, 17, 21

INCHTRODE N75F PPS - Ryton HF moderate 0...14 EVEREF-L POLISOLVE 1 SINGLE PORE Ring 2 µS/cm -10...130°C < 10 bar 2 x NPT 3/4“ 17, 21, 24

INCHTRODE N75P PPS - Ryton PHI moderate 0...14 EVEREF-L POLISOLVE 1 SINGLE PORE Ring 50 µS/cm 0...130°C < 10 bar 2 x NPT 3/4“ 21, 24

IONOTRODE Glass F very low 0...14 EVEREF 3M KCl 1 Ring, removable 0.2 µS/cm -10...40°C < 0.5 bar ** 120 mm PG 13.5 16

LIQ-GLASS PG Glass F low 1...12 EVEREF liquid 3 Ceramic 2 µS/cm -5...60°C < 2 bar 120 mm PG 13.5 16

MECOTRODE Glass H moderate 0...14 EVEREF Gel 3 HP ceramic 50 µS/cm 0...130°C < 16 bar various various 19, 23

OXYTRODE PT Glass Platinum — +/- 2000 mV EVEREF Gel 3 HP ceramic 50 µS/cm -10...130°C < 16 bar 120 mm PG 13.5 19, 23

pHeasy Glass H moderate 0...14 EVEREF-L POLISOLVE 2 SINGLE PORE 2 µS/cm 0...60°C < 6 bar various PG 13.5 17, 19, 23

pHeasy HT Glass PHI moderate 0...14 EVEREF-L POLISOLVE 2 SINGLE PORE 50 µS/cm 0...130°C < 6 bar various PG 13.5 13, 17, 19

POLILYTE HT Glass H moderate 0...14 EVEREF-L POLISOLVE 2 SINGLE PORE 2 µS/cm 0...130°C < 6 bar various various 15, 18

POLILYTE PLUS Glass H moderate 0...14 EVEREF-L POLISOLVE PLUS 2 SINGLE PORE 2 µS/cm 0...130°C < 6 bar various various 17, 18

POLILYTE PRO Glass V low 0...14 EVEREF-B POLISOLVE 1 SINGLE PORE 2 µS/cm -10...60°C < 6 bar 120 mm various 16, 22

POLILYTE PRO XP Glass V low 0...14 EVEREF-B POLISOLVE 1 SINGLE PORE 2 µS/cm -10...60°C < 50 bar 120 mm PG 13.5 16, 22

POLILYTE RX Glass Platinum — +/- 2000 mV EVEREF-B POLISOLVE 1 SINGLE PORE 5 µS/cm -10...60°C < 6 bar various PG 13.5 22

POLYCLAVE Glass PHI moderate 0...14 EVEREF-L POLISOLVE 2 SINGLE PORE 50 µS/cm 0...130°C < 6 bar various various 15

POLYPLAST PRO Plastic V moderate 0...14 Ag/AgCl POLISOLVE 1 SINGLE PORE 5 µS/cm -10...40/60°C < 6 bar 120 mm various 22

POLYPLAST PRO RX Plastic Platinum — +/- 2000 mV Ag/AgCl POLISOLVE 1 SINGLE PORE 5 µS/cm -10...40/60°C < 6 bar 120 mm various 22

* at 25°C; ** Dependent on positioning of electrolyte container; *** Not suitable for citric acid and frequent contact with hot alkali, as in CIP cleaning

Technical Data: pH Sensors

Page 46: Process Sensors Hamilton

– 46 –

Alphabetical Index

Description . . . . . . . . . . . . . . . . Page Description . . . . . . . . . . . . . . . . Page Description . . . . . . . . . . . . . . . . Page

6-in-1 . . . . . . . . . . . . . . . . . . . . . 30

ANSI . . . . . . . . . . . . . . . . . . . 34, 40

Armature . . . . . . . . . . . . . . . . 33-40

Autoclavation . . . . . . . . . . . . 12-15

Cables . . . . . . . . . . . . . . . . . . . . . 32

CHEMOTRODE . . . . . . . . . . . . 14, 20

CHEMOTRODE BRIDGE . . . . . 20, 24

CHEMOTRODE ORP . . . . . . . . 14, 20

CHEMOTRODE P . . . . . . . . . . 14, 20

CLARYTRODE . . . . . . . . . . . . . 19, 23

CONDUCELL . . . . . . . . . . . . . . 30-31

Conductivity . . . . . . . . 6, 8-9, 30-31

DELTATRODE . . . . . . . . . . . . . 21, 24

DIN plug . . . . . . . . . . . . . . . . . . . 32

DURACAL . . . . . . . . . . . . . 6, 10-11

EASYCONTROL . . . . . . . . . . . . . . 22

EASYCONTROL ORP . . . . . . . . . . . 22

EASYFERM . . . . . . . . . . . . . . . . . 13

EASYFERM PLUS . . . . . . . . . . 13, 18

EVEREF . . . . . . . . . . . . . . . . . . . . . 4

FERMOTRODE . . . . . . . . . . . . . . 14

FLANGE . . . . . . . . . . . . . . . . . 34, 40

FLANGE-ADAPTER . . . . . . . . . . . . 34

FLEXIFIT BIO . . . . . . . . . . . . . . . . 33

FLEXIFIT TC . . . . . . . . . . . . . . . . . 33

FLEXIFIT VV . . . . . . . . . . . . . . . . . 33

FLEXIFLANGE . . . . . . . . . . . . . . . . 34

FLEXIFLOW SL 10 . . . . . . . . . . . . . 34

Flow-through cell . . . . . . . . . . . . . 40

HF . . . . . . . . . . . . . . . . . . . . . 19, 23

Hydrofluoric . . . . . . . . . . . . . . 19, 23

Immersing . . . . . . . . . . . . . . . . . . 40

Ion Weak . . . . . . . . . . . . . . . . . 5, 16

INCHTRODE . . . . . . . . 15, 17, 21, 24

IONOTRODE . . . . . . . . . . . . . . . . . 16

JACOTRODE VP . . . . . . . . . . . . . . 30

K8 . . . . . . . . . . . . . . . . . . . . . . . . 32

LIQ-GLASS PG . . . . . . . . . . . . . . 16

MASTERFIT . . . . . . . . . . . . . . . . 35

MECOTRODE . . . . . . . . . . . . . 19, 23

MEMBRANE KIT . . . . . . . . . . . . . 29

N.I.S.T. . . . . . . . . . . . . . . . . . . . 8-11

OXYFERM . . . . . . . . . . . . . . . . . . 28

Oxygen . . . . . . . . . . . . . . . 5, 26-29

OXYGOLD . . . . . . . . . . . . . . . . 5, 29

OXYLYTE . . . . . . . . . . . . . . . . 28-29

OXYSENS . . . . . . . . . . . . . . . . . . . 28

OXYTRODE PT . . . . . . . . . . . . . . . 23

pHeasy . . . . . . . . 6-7, 13, 17, 19, 23

pH SIMULATOR . . . . . . . . . . . . . . 25

pH PATHFINDER . . . . . . . . . . . . . . 12

POLARIZATION MODULE . . . . . . . 29

POLILYTE HT . . . . . . . . . . . . . 15, 18

POLILYTE PLUS VP . . . . . . . . . 17, 18

POLILYTE PRO . . . . . . . . . . . . 16, 22

POLILYTE PRO XP . . . . . . . . . . 16, 22

POLILYTE RX . . . . . . . . . . . . . . . . 22

POLISOLVE . . . . . . . . . . . . . . . . . . . 4

POLYCLAVE . . . . . . . . . . . . . . . . . 15

POLYPLAST PRO . . . . . . . . . . . . . . 22

POLYPLAST PRO RX . . . . . . . . . . . 22

Pressure Adapter . . . . . . . . . . 35, 38

Retractable . . . . . . . . . . . . . . 36-39

RETRACTOFIT . . . . . . . . . . . . . . . . 36

RETRACTOFIT BIO . . . . . . . . . . . . 37

RETRACTOFIT PEEK . . . . . . . . . . . 36

RETRACTOMASTER . . . . . . . . . . 38

RETRACTOMATIC . . . . . . . . . . . . . 39

S7 . . . . . . . . . . . . . . . . . . . . . . . . 32

Service Kits . . . . . . . . . . . . . . 33-39

SIMULATOR . . . . . . . . . . . . . . . . . 25

SINGLE PORE . . . . . . . . . . . . . . . . 4

Socket . . . . . . . . . . . . . . . . . . . . 40

Specifications . . . . . . . . . . . . 42-45

Storage Solution . . . . . . . . . . 13-30

Traceable . . . . . . . . . . . . . . . . . 8-11

TriClamp . . . . . . . . . . . . . 31, 33, 40

VARIVENT . . . . . . . . . . . . . . . . . 33

VP . . . . . . . . . . . . . . . . . . . . . . . 32

Weld-in socket . . . . . . . . . . . . . . 40

Page 47: Process Sensors Hamilton

– 47 –

Numerical Index

237 100 . . . . . . . . . . 28237 110 . . . . . . . . . . 28237 118 . . . . . . . 28-29237 123 . . . . . . . 28-29237 126 . . . . . . . 28-29237 135 . . . . . . . . . . 29237 136 . . . . . . . 28-29237 138 . . . . . . . . . . 29237 139 . . . . . . . . . . 29237 140 . . . . . . . 28-29237 150 . . . . . . . . . . 28237 158 . . . . . . . . . . 40237 175-OP . . . . . . . . 28237 180 . . . . . . . . . . 29237 185 . . . . . . . . . . 29237 200-OP . . . . . . . . 35237 202 . . . . . . . . . . 40237 225-OP . . . . . . . . 35237 229 . . . . . . . . . . 35237 230 . . . . . . . . . . 40237 235-OP . . . . . . . . 35237 239 . . . . . . . . 36, 38237 240 . . . . . . . . . . 36237 250 . . . . . . . . . . 38237 252 . . . . . . . 35, 38237 260 . . . . . . . . . . 39237 290 . . . . . . . . . . 39237 306 . . . . . . . . . . 28237 319 . . . . . . . . 34-35237 320 . . . . . . . . . . 34237 331-OP . . . . . . . . 33237 338 . . . . . . . 33, 37237 339 . . . . 36, 38-39237 340 . . . . . . . 16, 34237 341 . . . . . . . . . . 33237 344 . . . . . . . . . . 33237 345 . . . . . . . . . . 33237 350 . . . . . . . . . . 29237 360 . . . . . . . . . . 29237 370 . . . . . . . . . . 29237 395 . . . . . . . . . . 29237 396 . . . . . . . . . . 29237 400 . . . . . . . . . . 28237 401 . . . . . . . . . . 28237 402 . . . . . . . . . . 28237 427 . . . . . . . . . . 29237 437 . . . . . . . . . . 29237 440 . . . . . . . . . . 37237 450 . . . . . . . . . . 28237 452 . . . . . . . . . . 28237 453 . . . . . . . . . . 28237 454 . . . . . . . . . . 28237 455 . . . . . . . . . . 28237 480 . . . . . . . . . . 37237 490 . . . . . . . . . . 36237 550 . . . . . . . . . . 25237 552 . . . . . . . . . . 25237 556 . . . . . . . . . . 25237 560 . . . . . . . . . . 25237 566 . . . . . . . . . . 25237 600 . . . . . . . . . . 30

237 620 . . . . . . . . . . 30237 627 . . . . . . . . . . 30237 630 . . . . . . . . . . 30237 640 . . . . . . . . . . 31237 650 . . . . . . . . . . 31237 700 . . . . . . . . . . 31237 710 . . . . . . . . . . 31237 750 . . . . . . . . . . 31237 760 . . . . . . . . . . 31237 910 . . . . . . . . . . 34237 930 . . . . . . . 34, 40237 931 . . . . . . . . . . . 40238 037 . . . . . . . 20, 24238 038 . . . . . . . 14, 20238 187 . . . . . . . . . . 11238 188 . . . . . . . . . . 11238 194 . . . . . . . . . . 11238 216 . . . . . . . . . . 11238 217 . . . . . . . . . . 11238 218 . . . . . . . . . . 11238 219 . . . . . . . . . . 11238 223 . . . . . . . . . . 11238 227 . . . . . . . . . . 11238 228 . . . . . . . . . . 11238 271 . . . . . . . . . . 11238 272 . . . . . . . . . . 11238 273 . . . . . . . . . . 11238 274 . . . . . . . . . . 11238 275 . . . . . . . . . . 11238 276 . . . . . . . . . . 11238 277 . . . . . . . . . . 11238 278 . . . . . . . . . . 11238 279 . . . . . . . . . . 11238 317 . . . . . . . 11, 25238 318 . . . . . . . 11, 25238 319 . . . . . . . 11, 25238 321 . . . . . . . 11, 25238 322 . . . . . . . . . . 11238 332 . . . . . . . . . . 11238 333 . . . . . . . . . . 11238 342 . . . . . . . 21, 24238 346 . . . . 17, 21, 24238 352 . . . . 15, 17, 21238 359 . . . . . . . 21, 24238 364 . . . . 17, 21, 24238 408 . . . . . . . . . . 22238 409 . . . . . . . . . . 22238 411 . . . . . . . 16, 22238 417 . . . . . . . 16, 22238 428 . . . . . . . 15, 18238 429 . . . . . . . 15, 18238 431 . . . . . . . 15, 18238 432 . . . . . . . 15, 18238 433 . . . . . . . . . . 22238 434 . . . . . . . . . . 22238 437 . . . . . . . 19, 23238 442 . . . . . . . . . . 30238 443 . . . . . . . . . . 30238 449 . . . . . . . 15, 18238 450 . . . . . . . . . . 15238 451 . . . . . . . . . . 15

238 453 . . . . . . . . . . 15238 454 . . . . . . . . . . 15238 455 . . . . . . . . . . 15238 456 . . . . . . . . . . 15238 457 . . . . . . . . . . 15238 458 . . . . . . . . . . 15238 459 . . . . . . . . . . 15238 467 . . . . . . . 15, 18238 480 . . . . . . . . . . 14238 482 . . . . . . . . . . 14238 484 . . . . . . . . . . .14238 486 . . . . . . . . . . 14238 490 . . . . . . . . . . 13238 492 . . . . . . . . . . 13238 494 . . . . . . . . . . 13238 498 . . . . . . . . . . 13238 515 . . . . . . . . . . 16238 522 . . . . . . . . . . 22238 523 . . . . . . . . . . 22238 525 . . . . . . . . . . 16238 550 . . . . . . . . . . .25238 552 . . . . . . . . . . .25238 556 . . . . . . . . . . .25238 560 . . . . . . . . . . 25238 566 . . . . . . . . . . 25238 625 . . . . . . . . . . 18238 627 . . . . . . . . . . 18238 628 . . . . . . . . . . 18238 629 . . . . . . . . . . 18238 630 . . . . . . . . . . 18238 633 . . . . . . . . . . 18238 634 . . . . . . . . . . 18238 635 . . . . . . . . . . 18238 636 . . . . . . . . . . 18238 640 . . . . . . . 21, 24238 643 . . . . . . . . . . 18238 644 . . . . . . . . . . 18238 645 . . . . . . . . . . 18238 674 . . . . . . . . . . 18238 740 . . . . . . . 14, 20238 742 . . . . . . . 14, 20238 744 . . . . . . . 14, 20238 746 . . . . . . . 14, 20238 753 . . . . . . . 20, 24238 754 . . . . . . . 20, 24238 756 . . . . . . . 20, 24238 760 . . . . . . . 14, 20238 761 . . . . . . . 14, 20 238 762 . . . . . . . 14, 20238 763 . . . . . . . 14, 20238 764 . . . . . . . 14, 20238 765 . . . . . . . 14, 20238 766 . . . . . . . 14, 20238 767 . . . . . . . 14, 20238 770 . . . . . . . 20, 24238 772 . . . . . . . 20, 24238 774 . . . . . . . 20, 24238 775 . . . . . . . . . . 20238 776 . . . . . . . 20, 24238 801 . . . . . . . . 19, 23238 806 . . . . . . . 19, 23

238 810 . . . . . . . . 19, 23238 811 . . . . . . . 16, 22238 821 . . . . . . . 19, 23238 831 . . . . . . . 19, 23238 890 . . . . 17, 19, 23238 893 . . . . . . . 17, 19238 894 . . . . . . . 17, 19238 895 . . . . . . . . . . 11238 896 . . . . . . . . . . 11238 897 . . . . . . . . . . 11238 898 . . . . . . . . . . 11238 917 . . . . . . . . . . 11238 918 . . . . . . . . . . 11238 919 . . . . . . . . . . 11238 922 . . . . . . . . . . 11238 923 . . . . . . . . . . 11238 924 . . . . . . . . . . 11238 926 . . . . . . . . . . . 9238 927 . . . . . . . . . . . 9238 928 . . . . . . . . . . . 9238 931 . . . . . 13-24, 30238 934 . . . . . . . . . . . 9238 936 . . . . . . . . . . 16238 937 . . . . . . . 20, 24238 939 . . . . . . . 14, 20238 973 . . . . . . . . . . . 9238 984 . . . . . . . . . . . 9238 985 . . . . . . . . . . . 9238 986 . . . . . . . . . . . 9238 988 . . . . . . . . . . . 9242 428 . . . . . . . 17, 18242 429 . . . . . . . 17, 18242 439 . . . . . . . 17, 18242 442 . . . . . . . 17, 18242 449 . . . . . . . 17, 18 242 700 . . . . . . . 14, 20242 701 . . . . . . . 14, 20355 043 . . . . . . . . . . 32355 045 . . . . . . . . . . 32355 056 . . . . . . . . . . 32355 057 . . . . . . . . . . 32355 058 . . . . . . . . . . 32355 059 . . . . . . . . . . 32355 066 . . . . . . . . . . 32355 072 . . . . . . . . . . 32355 080 . . . . . . . . . . 32355 087 . . . . . . . . . . 32355 088 . . . . . . . . . . 32355 089 . . . . . . . . . . 32355 108 . . . . . . . . . . 32355 109 . . . . . . . . . . 32355 110 . . . . . . . . . . 32355 111 . . . . . . . . . . 32355 112 . . . . . . . . . . 32355 153 . . . . . . . . . . 32355 154 . . . . . . . . . . 32355 155 . . . . . . . . . . 32355 156 . . . . . . . . . . 32

Order No. . . . . . . . . Page Order No. . . . . . . . . Page Order No. . . . . . . . . Page Order No. . . . . . . . . Page

Page 48: Process Sensors Hamilton

http://www.hamiltoncompany.com

[email protected]

Hamilton AGVia Crusch 8CH-7402 Bonaduz, SwitzerlandToll-Free: 00800-660-660-60Telephone: +41-81-660-60-60Fax: [email protected]

Hamilton Company4970 Energy WayReno, Nevada 89520 USAToll-Free: 800-648-5950Telephone: +1-775-858-3000Fax: [email protected]

Hamilton Quality Products:Laboratory ElectrodesDURACAL™ pH BuffersConductivity SensorsConductivity StandardsDissolved Oxygen SensorsArmatures for SensorsMICROLITER™-SyringesGASTIGHT®-SyringesInstrument SyringesSoftGrip™-PipettesMiniature Valves

Laboratory Automation for:Drug DiscoveryGenomicsProteomicsForensicsIn Vitro Diagnostics

Your HAMILTON representative:

The following Hamilton trademarks have been used in this catalog:

CHEMOTRODECLARYTRODECOATRAMICCONDUCELLDELTATRODEDURACALEASYCONTROLEASYFERMEVEREFFERMOTRODEFLEXIFITINCHTRODEIONOTRODEJACOTRODE LIG-GLASSMASTERFITMECOTRODE

OXYFERMOXYGOLDOXYLYTEOXYSENSOXYTRODEpHEASYPHERMLYTEPOLILYTEPOLISOLVEPOLYCLAVEPOLYPLASTPROTELYTERETRACTOFITRETRACTOMASTERRETRACTOMATICSINGLE PORESKYLYTE

P/N: 690 127 / 03 02-2006