Process for Infection Control - Jangro · Process for Infection Control Wash hands with...

1
Professional Process for Infection Control Wash hands with antibacterial soap and water, then sanitise with alcohol gel. 1 Infection Control - effective against bacteria including MRSA (EN1276) Put on disposable PPE and place safety signs. 2 Ensure any sharps and other hazardous waste is removed safely into a sharps container. 3 Safely remove any body fluid spills with absorbent granules and a disposable scoop. 4 1 BA051-75 750ml Professional Medical Sanitiser Spray all surfaces and equipment with Jangro Medical Sanitiser or Cleaner Disinfectant. Leave for recommended contact time. 5 Wipe thoroughly with a disposable wipe or cleaning cloth. Replace cloth with new as soon as contaminated with soiling. 6 Place all waste including any used cloths and disposable PPE in waste bag for appropriate disposal. Seal bag before leaving area. 7 Wash hands with antibac soap & then dry with disposable towel & when dry, alcohol sanitiser can be applied. Wash hands with antibacterial soap and water then sanitise with alcohol gel. 1 Cleaning potentially infectious areas of E-coli, Clostridium difficile or H.I.V (EN1276, EN13704, EN1650, EN14476, EN14675) Put on disposable PPE and place safety signs. Some infections can become air-borne - Please wear a mask! 2 3 VIRUCIDAL CLEANER E-coli & C-diff: Dilute 60ml of Jangro Virucidal Cleaner to 600ml (1:10) warm water into a spray bottle. H.I.V: Dilute 1:40. Label bottle appropriately. 4 8 VIRUCIDAL CLEANER Spray surface and leave for...30 seconds (E-coli), 60 mins (C-diff) or 5 mins (H.I.V.), then wipe clean. 5 Place all waste including any used cloths and disposable PPE in waste bag for appropriate disposal. Seal bag before leaving area. 6 Wash hands with antibac soap & then dry with disposable towel. 7 When dry, alcohol sanitiser can be applied. Wash hands with antibacterial soap and water then sanitise with alcohol gel. 1 Potential outbreak of Norovirus (EN1276, EN13704, EN1650, EN14476, EN14675) Put on disposable PPE and place safety signs. Some infections can become air-borne - Please wear a mask! 2 3 VIRUCIDAL CLEANER Dilute 60ml of Jangro Virucidal Cleaner to 600ml (1:10) warm water into a spray bottle. Label bottle appropriately. 4 8 VIRUCIDAL CLEANER Spray surface and leave for 5 minutes, then wipe clean. 5 Place all waste in waste bag. Seal bag and place in appropriate area for disposal. 6 Wash hands with antibac soap & then dry with disposable towel. 7 When dry, alcohol sanitiser can be applied. 8 Blot affected area with an absorbent material. CAUTION CLEANING IN PROGRESS CAUTION CLEANING IN PROGRESS CAUTION CLEANING IN PROGRESS Ensure any sharps and other hazardous waste is removed safely into a sharps container. Remove any body fluid spills with absorbent granules and a disposable scoop. 600ml 60ml 25 35 20 40 10 50 45 15 30 55 5 60 600ml 60ml Products used: Virucidal Cleaner, Medical Sanitiser/Cleaner Disinfectant XA157 www.jangro.net N.B. This document is offered as guidance only. It is your responsibility to ensure that it reflects the use of the product in your operation and amend accordingly.

Transcript of Process for Infection Control - Jangro · Process for Infection Control Wash hands with...

Page 1: Process for Infection Control - Jangro · Process for Infection Control Wash hands with antibacterial soap and water, then sanitise with alcohol gel. 1 Infection Control - effective

Professional

Process for Infection Control

Wash hands with antibacterial soap andwater, then sanitise with alcohol gel.

1

Infection Control - effective against bacteria including MRSA (EN1276)

Put on disposable PPE and place safetysigns.

2 Ensure any sharps and other hazardouswaste is removed safely into a sharpscontainer.

3 Safely remove any body fluid spills withabsorbent granules and a disposablescoop.

4

1

BA051-7

5

750m

l

Professio

nal

Medic

al

Sanitiser

EFFECTIVE AGAINST

BACT

ERIA & VIRUSES •

Spray all surfaces and equipment withJangro Medical Sanitiser or CleanerDisinfectant. Leave for recommendedcontact time.

5 Wipe thoroughly with a disposable wipe orcleaning cloth. Replace cloth with new assoon as contaminated with soiling.

6 Place all waste including any used clothsand disposable PPE in waste bag forappropriate disposal. Seal bag beforeleaving area.

7 Wash hands with antibac soap & then drywith disposable towel & when dry, alcoholsanitiser can be applied.

Wash hands with antibacterial soap andwater then sanitise with alcohol gel.

1

Cleaning potentially infectious areas of E-coli, Clostridium difficile or H.I.V (EN1276,EN13704, EN1650, EN14476, EN14675)

Put on disposable PPE and place safety signs.Some infections can become air-borne -Please wear a mask!

2 3

VIRUCIDALCLEANER

E-coli & C-diff: Dilute 60ml of JangroVirucidal Cleaner to 600ml (1:10) warmwater into a spray bottle. H.I.V: Dilute 1:40.Label bottle appropriately.

4

8

VIRUCIDAL

CLEANER

Spray surface and leave for...30 seconds(E-coli), 60 mins (C-diff) or 5 mins (H.I.V.),then wipe clean.

5 Place all waste including any used clothsand disposable PPE in waste bag forappropriate disposal. Seal bag beforeleaving area.

6 Wash hands with antibac soap & then drywith disposable towel.

7 When dry, alcohol sanitiser can beapplied.

Wash hands with antibacterial soap andwater then sanitise with alcohol gel.

1

Potential outbreak of Norovirus (EN1276, EN13704, EN1650, EN14476, EN14675)

Put on disposable PPE and place safety signs.Some infections can become air-borne -Please wear a mask!

2 3

VIRUCIDALCLEANER

Dilute 60ml of Jangro Virucidal Cleaner to 600ml (1:10) warm water into a spraybottle. Label bottle appropriately.

4

8

VIRUCIDAL

CLEANER

Spray surface and leave for 5 minutes,then wipe clean.

5 Place all waste in waste bag. Seal bagand place in appropriate area fordisposal.

6 Wash hands with antibac soap & then drywith disposable towel.

7 When dry, alcohol sanitiser can beapplied.

8

Blot affected area with an absorbentmaterial.

CAUTION

CLEANINGIN PROGRESS

CAUTION

CLEANINGIN PROGRESS

CAUTION

CLEANINGIN PROGRESS

Ensure any sharps and other hazardous waste is removed safely into a sharps container.Remove any body fluid spills with absorbentgranules and a disposable scoop.

600ml

60ml

25352040

1050

45 15

30

55 560

600ml

60ml

Products used: Virucidal Cleaner,Medical Sanitiser/Cleaner Disinfectant

XA157www.jangro.net N.B. This document is offered as guidance only.It is your responsibility to ensure that it reflects the use ofthe product in your operation and amend accordingly.