Premium DrywallSystems & Partitions
Water Resistant
Fire Resistant
Impact Resistant
Water Resistant
Fire Resistant
Impact Resistant
-
8/11/2019 PRIMA Drywall
2/12
PRIMA Premium DrywallSystems & Partitions
Why specifically PRIMA Premium Drywall ?
Drywall construction is applied in a dry condition without the use of mortar. The materials used in PRIMA premiumdrywall construction are Boral gypsum boards, PRIMA fibre cement boards and Rondo Zincalume steel stud. Thelarge Boral and PRIMA board size sheets are fastened directly to Rondo steel stud frames with self drillingscrews.
The lightweightness of the materials together combined with the ease and simplicity of construction makes it thepreferred wall construction method option. In places where supply is a problem or in construction sites wherewater is barely accessible, drywall construction method becomes the absolute preferred choice.
Boral, PRIMA and Rondo collaborate to set a quality benchmark for the construction of drywall systems where theuser and specifiers can be sure of premium products and performance for:
Water resistant Fire resistant Impact resistant Soundproof
All three companies are established leaders for their respective building materials used as the main componentsfor drywall constructions to achieve optimum system performance. Boral and Rondo are related companiessynonymous with their market leadership in gypsum board system solution while PRIMA fibre cement boardsknown for its superior water and impact resistant properties are supplied to over 60 countries worldwide.
All three companies therefore serve to complement and enhance the delivery of drywall construction productsand solution to builders in Malaysia and worldwide. Therefore it makes sense to insist on PRIMA PremiumDrywall Systems for your drywall construction requirements.
1
Water Resistant Fire Resistant Impact Resistant
-
8/11/2019 PRIMA Drywall
3/12
Water Resistant Fire Resistant Impact Resistant
2
PRIMA Premium Drywall is tested to the levels of fire resistance required by building codes and standards.
Impact on walls come in three basic forms; soft body, abrasive and hard body. Each of these can affect the walllining in different ways and consequently affect the choice of lining system. When PRIMA Premium Drywall areproperly sealed and used in a certified sound rated assembly, these products will contribute to required soundtransmission classification (STC) values.
PRIMA Premium Drywall offer the following key advantages: Strong and durable Lightweight Easy installation Cost effective Aesthetically pleasing Superior water & impact resistance
-
8/11/2019 PRIMA Drywall
4/12
PRIMA Premium Drywall System Overview(PRIMA + BORAL + RONDO)
PRIMA Premium Drywall is made up of: PRIMA liner fibre cement boards Boral Firestop boards Rondo Zincalume steel stud
Note:The above diagrams show typical detailsof PRIMA Premium Drywall Systems.
Actual system configuration may bedifferent. Refer to System Components& Properties table for more information.
Note: For PSB tested systems, refer to System Components & Properties table for more information.
3
Rondo top track
Rondo bottomtrack
Rondo steel stud
16mm BoralPlasterboard toeach side
9mm PRIMA liner to each side
114mm 64mm Stud Width
2 layers boards
2 layers boards1 layer 9mm PRIMA liner 1 layer 16mm Boral Firestop
1 layer 16mm Boral Firestop1 layer 9mm PRIMA liner
PRIMA Premium Drywall PRIMA Premium Drywall is SIRIM tested in accordance to BS 476: Part 22. PRIMA Premium Drywall is available in two fire rated systems - 1 hour and 2 hours non-load bearing drywall system.
PRIMA Premium Drywall Systems incorporates Rondos light gauge Zincalume steel framing with Boral gypsumboard underlay with PRIMA liner facing board. Board thicknesses for required fire resistance level as follows:
Fire Rating Requirement
1 hour Fire Rating
2 hours Fire Rating
PRIMA liner Board Thicknesses
9mm
9mm
Boral Firestop Board Thicknesses
12.5mm (Regular)
16mm (Firestop)
DRYWALLPremium Wall Systems
-
8/11/2019 PRIMA Drywall
5/124
Fire Resistant All components that make up these drywall systems possess superior firerating properties. The steel framing system is naturally non-combustible.The lining materials (fibre cement board & plasterboard) have been testedby SIRIM and classified as Class O building material under the MalaysiaUniform Building By-law 1984.
The components/systems have been tested in SIRIM Berhad and PSBSingapore in accordance with BS 476: Fire tests on building material andstructure. The test results are as follows:- Fire Propagation Index of Performance, I < 12 (BS 476: Part 6) Surface Spread of Flame Class 1 (BS 476: Part 7) Non-load bearing drywall system One and Two hours rating (BS 476: Part 22)
Water Resistant The facing board in the PRIMA Premium Drywall Systems is PRIMA liner9mm fibre cement board which has superior wet resistant properties.PRIMA liner is made from a recipe mix of cement, sand and pulp.PRIMA liner has been tested by various certification bodies and authoritiesfor its water resistant properties.
PRIMA liner superior water resistant property has been proven after passingthe several test listed below:- Test to AS 3991.5 : Resistance to Hot Water Soaking Test to AS 3991.6 : Resistance to Heat and Rain Test to AS 3991.7 : Resistance to Freeze and Thaw
Upon completion of the test, PRIMA liner remains intact and there were nosigns of delamination or structural alteration observed on the test specimens.
Applications & Advantages
PRIMA Premium Drywall Fire Rated wall systems shown in this manual are suitable to be applied as internalnon-load bearing wall/partition for residential or commercial buildings.
The use of the fire rated wall systems described in this manual shall be governed by the Malaysia Uniform BuildingBy-law, Fire Rescue Department (Bomba) and the local authority regulation.
Impact Resistant PRIMA fibre cement boards ability to withstand impact is undoubted sinceit is a cement-sand based product with concrete-like strength. When usedas a facing board of PRIMA Premium Drywall Systems, it is just the perfectdurable and strong board for drywall construction to withstand hardknocks in areas of high traffic and rough handling.
PRIMA Premium Drywall Systems have the advantage of being more solidand resistant to impact loads compared with traditional drywall systems.Impact loads come in three basic forms: soft body, abrasive as well as hardbody. The drywall systems covered in this manual give you peace of mindknowing that you have already chosen or specified the systems that work.
Designing wall systems to achieve the required Sound Transmission Class(STC) value has been facilitated with the introduction of PRIMA PremiumDrywall Systems. The acoustic properties of these systems have been testedin SIRIM Berhad Malaysia and PSB Singapore. The systems STC ratingranges from 45dB to 60dB.
-
8/11/2019 PRIMA Drywall
6/125
System Components & Properties
Basic components and the typical properties of fire rated, non-load bearing wall system - steel frame.
-
8/11/2019 PRIMA Drywall
7/126
Notes:
1. * These STC values are based on estimation only.
2. In order HCI systems to perform as tested, all components must install exactly as prescribed.
-
8/11/2019 PRIMA Drywall
8/127
Framing
Framing member must be fabricated using light gaugeZincalume or equivalent steel sections having a minimum of0.50mm base metal thickness (0.55mm total coated thickness)with spacing not exceeding the following centre distance: Stud - 600mm (610mm) maximum Noggings - not exceeding 1200mm (1220mm) and as described in the diagram
The actual studs and noggings sizes shall be selected basedon the above table. Should fire rating or (and) sound insulationis required, refer to System Components & Properties tablefor additional requirements.
Table 1A : Internal Non-Load Bearing Walls (L/240 ) for PRIMA liner fibre cement board
MAXIMUM WALL HEIGHTS TABLES:Rondo Steel Stud for
35
35
51, 64, 76, 92 & 150mm
51, 64, 76, 92 & 150mm
C-Channel
U-Channel
Table 1B : Internal Non-Load Bearing Walls (L/360 ) for PRIMA liner fibre cement board
STUD WIDTHBMT
RONDO Part No.
51mm0.50mm
4010.75mm
489
64mm0.50mm
1120.75mm
4911.15mm
661
26802680
29003310
29302920
39003890
41504410
31103290
33003660
36003590
42504500
45804790
33703710
36003920
39304150
45304750
49205110
PRIMA liner Board (mm) SINGLE STUD @ 600 mm CENTRES
SINGLE STUD @ 400 mm CENTRES
SINGLE STUD @ 300 mm CENTRES
Lined both sides1 x 6.0 mm1 x 9.0 mm
PRIMA liner Board (mm)
Lined both sides1 x 6.0 mm1 x 9.0 mm
PRIMA liner Board (mm)
Lined both sides1 x 6.0 mm1 x 9.0 mm
STUD WIDTHBMT
RONDO Part No.
51mm0.50mm
401
0.75mm
489
64mm0.50mm
112
0.75mm
491
1.15mm
661
25202680
26502990
29302920
34603700
36703890
28003120
29803270
32603540
37503950
40304210
30103300
32203490
34803730
39804170
43204480
PRIMA liner Board (mm) SINGLE STUD @ 600 mm CENTRES
SINGLE STUD @ 400 mm CENTRES
SINGLE STUD @ 300 mm CENTRES
Lined both sides1 x 6.0 mm1 x 9.0 mm
PRIMA liner Board (mm)
Lined both sides1 x 6.0 mm1 x 9.0 mm
PRIMA liner Board (mm)
Lined both sides1 x 6.0 mm1 x 9.0 mm
-
8/11/2019 PRIMA Drywall
9/128
Notes to Tables 1A & 1B:
1. Deflection Limit is span/240 (or span/360 as applicable) to a maximum of 30mm at 0.25 kPa, in accordance with the BCA Specification CI.8 - 2005.
2. Maximum wall heights refer to the structural wall heights only. Maximum wall heights may be reduced from those in the table for fire rated walls,refer to your plasterboard manufacturer for this information.
3. The tabulated heights are not for axial loads but do include self weight and lateral pressures.
4. Shelf loading is not permitted on the tabulated wall heights.
5. Loadings: (a) P ultimate = 0.375 kPa (b) P service = 0.25 kPa
6. These walls are not for external applications.
7. All loading in accordance with AS1170:2002
8. Walls analysed in accordance with AS4600:1996
9. Noggings in accordance with tables shown on facing page.10. BMT = Base Metal thickness.
11. The above datas are applicable with RONDO products only.
RIMA Premium Drywall
92mm
0.55mm
251
0.75mm
495
1.15mm
681
35503850
48104990
51005740
47304720
54306020
58306370
53005460
58906420
63706850
150mm
0.75mm
511
1.15mm
691
65306510
72107510
73407600
79608180
78308050
85208700
76mm
0.55mm
403
0.75mm
493
1.15mm
671
35103510
44004390
46405200
41304310
49105390
52305710
44704800
52805740
56706090
SINGLE STUD @ 600 mm CENTRES
SINGLE STUD @ 400 mm CENTRES
SINGLE STUD @ 300 mm CENTRES
92mm
0.55mm
251
0.75mm
495
1.15mm
681
35503850
43904950
46505170
43704660
48905380
52405680
46704920
52705700
56906080
150mm
0.75mm
511
1.15mm
691
58306180
64006720
65206810
72407490
70807330
79108120
76mm
0.55mm
403
0.75mm
493
1.15mm
671
33203510
40004390
42004670
36903990
43904830
46805070
39704240
47005080
50405390
SINGLE STUD @ 600 mm CENTRES
SINGLE STUD @ 400 mm CENTRES
SINGLE STUD @ 300 mm CENTRES
-
8/11/2019 PRIMA Drywall
10/129
Fastening Requirement
The following fasteners are recommended to be used to construct the fire rated systems. Alternative fastenerswith equivalent size and suitable head type can also be used, but may require additional work such as sheetpre-drilling prior to installation.
PRIMA liner to Steel Frame
Self-drilling, Self-embeddingHead Screws
Plasterboard to Steel Frame
Bugle HeadPlasterboard Screws
Steel Frame Assembly
Wafer Head Screws
Sheet Installation
Gypsum Board Underlay - Apply sheethorizontally, ensuring vertical sheet jointon one side of the stud does not coincidewith the vertical sheet joint on the otherside.
PRIMA liner Lining - Apply sheet vertically,ensuring sheet joints on one side of thewall do not coincide with the sheet jointson the other side.
PRIMA liner vertical sheet joints must notcoincide to that of gypsum board. Whenapplied in wet areas such as forwashroom, ensure the wall system will notbe subjected to still water.
Please refer to HCIs comprehensive
installation instruction.
To secure steel frame to masonry wall/slab, use 3mm diameter x 50mm long concrete nails or M8 anchor boltsspaced at 600mm maximum centres.
PRIMA liner Fastener Edge Distances & Spacing
12mm min. from edge
50mm min. from corner
200mm centres max. at sheet perimeter
300mm centres max. elsewhere
Plasterboard Fastener Edge Distances & Spacing
12mm min. from edge
50mm min. from corner
300mm centres max. at sheet perimeter
400mm centres max. elsewhere
Typical Installation Detail
Note:The typical details shown in this section may only be applicable to selected PRIMAPremium Drywall Systems only. Always refer to HCI to request for specific systemdetails based on the desired wall systems.
Gypsum Board
200mm max.
300mm max.
Gypsum Board
9.0mm PRIMA liner
1 2 2 0 m m
m a x .
1 2 2 0 m m
m a x .
Bottom plate : 0.55mm thick x 64mmdeep Zincalume steel "u" channel fixedonto concrete floor
9.0mm PRIMA liner
Top plate:0.55mm thick x 64mmdeep Zincalume steel"U" channel
6 10mm c/c 6 10mm c/c 61 0mm c/c 61 0mm c/c 61 0mm c/c
12mm min.
50mm max.
DRYWALLPremium Wall Systems
-
8/11/2019 PRIMA Drywall
11/1210
Joint Systems
PRIMA liner sheet joints can be treated as described in thediagram, incorporating perforated paper jointing tape andplasterboard joint compound. Use only joint compoundproduced or supplied by reputable manufacturer.
Best result can be achieved when both PRIMA liner edgeshave recesses. Jointing non-recessed edges should beavoided. If it becomes necessary to flush set over non-recessed edges, the bedding layer, topping layer and finishinglayer should be broadened to 200mm, 400mm and 600mmrespectively.
The combination of recessed edge and square edge is notsuitable to be flush set.
Flush Joint (Rebated Edge)
Finishes
PRIMA liner can be decorated with 2 coats of 100% quality water-based acrylic paint. For general-purposeapplications, there is no requirement for primers or sealers.
Alternatively, the sheet surface can be decorated with wall covering materials, such as wall paper. In all cases,coating, coating manufacturers recommendations must be strictly adhered to. For wet area application, tilefinishing may be preferable.
Expansion Joint
Vertical expansion joints must be provided to accommodate anticipated movement within a building. PRIMAPremium Drywall Systems require expansion joints to be located vertically as follow:
Horizontal expansion joints must be provided at 3.6mm mazimum centres. Seal joint with flexible fire ratedsealant that is compatible with cementitious products.
Steel frame
Untiled walls
Tiled walls
0.50mm to 0.75mm BMT
9.0m
4.8m
0.75mm to 1.15mm BMT
6.0m
Vertical expansion joints maximum spacing
Gypsumboard
PRIMA liner
Joint compoundtopping layer
Joint compoundfinishing layer sanded to finish(Not required for tiled wall)
Perforated paper jointing tape
Joint compound beddinglayer to infill gap
Rondosteelstud
6 0 m m
2 0 0 m m
2 7 0 m m
Fire rated sealantover backer rod
Gypsum board
PRIMA liner lining
Rondo steel stud(provide completestructural break
at control joint)
Gypsum board
Fire rated sealant over backer rodStopping angle set flushwith joint compound
PRIMA liner lining
Fasteners
B
A
Min. 5mm gap
Tile adhesive
Ceramic tiles
-
8/11/2019 PRIMA Drywall
12/12
Hume Cemboard Industries Sdn Bhd (579898-W) A Member of the Hong Leong Group
Address No. 12, Jalan Tandang, P.O. Box 21, 46050 Petaling Jaya, Selangor Darul Ehsan, MalaysiaMalaysia Sales Tel: 603 - 7625 9999 Fax: 603 - 7625 7822 / 7833 Email: [email protected] Sales Tel: 603 - 7625 3880 Fax: 603 - 7625 3990 / 3991 Email: [email protected] www primaboard com
Water Resistant Fire Resistant Impact Resistant