Pretech Inspection Report.docx

20

Transcript of Pretech Inspection Report.docx

Date: 23.12.2014

Subject: Safety Inspection

Company: Precast Technology

On 22.12.204 around 12:02 pm, we conducted walk thru joint inspection with Engr. Ayman of DAR Safety Engineer together with PreTech Co. Safety Officer related to safety issues and concerns in the fabrication workarea. We observed some unsafe practices, workplace condition and work environment that are hazardous and harmful to direct workers. Listed below were visually found during our inspection.

1. No certification from 3rd party of cranes, equipments, riggers as per safety officer of Pretech Co.

2. No evacuation plan poster or signage.

3. No access signages i.e. Entry/ Exit

4. Monthly inspection of Fire Extinguishers were not being done

5. Fire hose reel cabinet were obstructed by materials

6. Unsafe single plank were placed as access being used

7. Fabricated rebar around 20mm dia.were being utilized

8. Poor housekeeping inside the work area

9. Damaged electric cables in powered tools

10. Exposed open wires of welding machine

11. Distribution box without locking device

12. Cylinder tank of acetylene without flashback arrestor

13. No proper and safe workarea of hotwork activity

14. No Lock Out/ Tag Out system

15. Scattered protruding nails on the plywood

16. Damaged rigging material (web sling)

17. Unsafe work platform more than 6 ft. high (unguarded and no access)

18. Hook does not have safety lock device (safety latch)

19. Improper placing of garbage bin causing of flies and unwanted odor.

20. Lack of safety prea

cautions posted like signages.

Safety control measures must strictly implemented accordingly. As per safety officer of Pretech Co.around 200 workers are working in day and night shift schedules.

Attached photo for reference.

Prepared by:

Florence Caasi CatabaySr. HSE Officer/ TAL JV