Pressure switches DRD, DRD-N, DRD-T - series diaphragm...

9
97 97 Technical data 1. DRD— series. 2. Hyphen. 3. Set point upper limit, mbar. 4. Pressure switch design: N — for excess pressure (head); Т — for under-pressure (thrust). 5. Type of pressure switch adjustment: А — for pressure rise measuring; B — for pressure reduction measuring. 6. Technical conditions number Name of switch Picture. Type of pressure measured Pressure range Return area range Max. operat- ing pressure Weight, gr., max. DRD–12 Pic. 1 Excess pressure (head) 3...12 mbar 1...3 mbar 0,6 bar 350 DRD–40 10...40 mbar 2...5 mbar DRD–120 30...120 mbar 10...30 mbar DRD–400 0,1...0,4 bar 20...80 mbar 1,5 bar DRD–1000 0,2...1,0 bar 20...100 mbar DRD–5Н Pic. 2 Excess pressure (head) 0,6...5 mbar 0,4...1,4 mbar 0,25 bar 450 DRD–10Н 1...10 mbar 0,5...2 mbar DRD–50Н 5...50 mbar 1,5...12 mbar DRD–300Н 0,03...0,3 bar 12...40 mbar 1,5 bar DRD–1000Н 0,2...1,0 bar 40...100 mbar DRD–5Т Pic. 3 Under-pres- sure (thrust) 0,6...5 mbar 0,4...1,4 mbar 50 мbar 750 DRD–10Т 1...10 mbar 0,5...2 mbar DRD–50Т 5...50 mbar 1,5...12 mbar Field of application Pressure switches are applied for excess pressure (head) and for under-pressure (thrust) control of natural, liquefied gas or air in gas supplying systems and ventilation systems. Housing parts of pressure switch are made of corrosion resistant materials (non-ferrous metal alloys, high-strength plastic, oil-and-gas-resistant rubber).The membrane is made of rubberized fabric.The cover is made of transparent plastic. Actuation pressure value is set by adjusting screw with a scale. Electrical wires are connected by contact clamping screws. Code structure 1 2 3 4 5 6 DRD - х х х, TU BY 200020142.025-2000 Pressure switches DRD, DRD-N, DRD-T - series diaphragm type Pic. 1 Pic. 2 Pic. 3

Transcript of Pressure switches DRD, DRD-N, DRD-T - series diaphragm...

Page 1: Pressure switches DRD, DRD-N, DRD-T - series diaphragm typetermobrest.net/sitefiles/1/5/35/all6_06_eng.pdf · 2018. 6. 28. · 99 Pic. 5. Overall dimensions of excess pressure switches

9797

Technical data

1. DRD— series.2. Hyphen.3. Set point upper limit, mbar.4. Pressure switch design: N — for excess pressure (head); Т — for under-pressure (thrust).5. Type of pressure switch adjustment: А — for pressure rise measuring; B — for pressure reduction measuring.6. Technical conditions number

Name of switch Picture. Type of

pressure measured

Pressure range

Return area range

Max. operat-ing pressure

Weight, gr., max.

DRD–12

Pic. 1Excess

pressure (head)

3...12 mbar 1...3 mbar

0,6 bar

350

DRD–40 10...40 mbar 2...5 mbar

DRD–120 30...120 mbar 10...30 mbar

DRD–400 0,1...0,4 bar 20...80 mbar1,5 bar

DRD–1000 0,2...1,0 bar 20...100 mbar

DRD–5Н

Pic. 2Excess

pressure (head)

0,6...5 mbar 0,4...1,4 mbar

0,25 bar

450

DRD–10Н 1...10 mbar 0,5...2 mbar

DRD–50Н 5...50 mbar 1,5...12 mbar

DRD–300Н 0,03...0,3 bar 12...40 mbar1,5 bar

DRD–1000Н 0,2...1,0 bar 40...100 mbar

DRD–5Т

Pic. 3 Under-pres-sure (thrust)

0,6...5 mbar 0,4...1,4 mbar

50 мbar 750DRD–10Т 1...10 mbar 0,5...2 mbar

DRD–50Т 5...50 mbar 1,5...12 mbar

Field of applicationPressure switches are applied for excess pressure (head) and for under-pressure (thrust)

control of natural, liquefied gas or air in gas supplying systems and ventilation systems.Housing parts of pressure switch are made of corrosion resistant materials (non-ferrous metal

alloys, high-strength plastic, oil-and-gas-resistant rubber).The membrane is made of rubberized fabric.The cover is made of transparent plastic. Actuation pressure value is set by adjusting screw with a scale. Electrical wires are connected by contact clamping screws.

Code structure

1 2 3 4 5 6

DRD - х х х, TU BY 200020142.025-2000

Pressure switches DRD, DRD-N, DRD-T - series diaphragm type

Pic. 1

Pic. 2

Pic. 3

Page 2: Pressure switches DRD, DRD-N, DRD-T - series diaphragm typetermobrest.net/sitefiles/1/5/35/all6_06_eng.pdf · 2018. 6. 28. · 99 Pic. 5. Overall dimensions of excess pressure switches

9898

Principal circuit

31

2

Characteristics Value

Temperature of environment, ОС –30...+60

Operation medium temperature, ОС –30...+60

Degree of protection IP54

CharacteristicsValue /

Active / Inductive /

Alternating current (AC)

125 V 3 2

250 V 2 1,5

Direct current (DC)

14 V 3 2

250 V 0,2 0,2

Rated max. load current for pressure switches DRD, A

BA

6070

80

1

Pic. 4. Overall dimensions of excess pressure switches DRD

Excess pressure switches (pic. 4) are connected to the system by threaded (G¼) holes A and B. If pressure is supplied through hole А, hole В is to be closed by plug 1, and vice versa.

It is recommended to install the pressure switch when membrane is in vertical position (such position is adjusted by the manufacturer for correct operation). If pressure switch is installed in a different way, monitoring errors may occur due to the influence of mass of the movable parts. In this case additional adjustment of pressure switch using reference manometer is required.

Pressure switches can be assembled into block units (e.g, in the case if upper and lower pressure limits control is required).

Page 3: Pressure switches DRD, DRD-N, DRD-T - series diaphragm typetermobrest.net/sitefiles/1/5/35/all6_06_eng.pdf · 2018. 6. 28. · 99 Pic. 5. Overall dimensions of excess pressure switches

9999

Pic. 5. Overall dimensions of excess pressure switches DRD-H

Pic. 6. Overall dimensions of under-pressure (thrust) switches DRD-TA

Excess pressure switches (pic. 4) are connected to the system by threaded (G¼) holes A and B. If pressure is supplied through hole А, hole В is to be closed by plug 1, and vice versa.

Under-pressure switches DRD-TA (pic. 6) are connected to the system by threaded hole C. It is necessary to keep one hole (A or B) open (connected with atmosphere).

It is recommended to install the pressure switch when membrane is in vertical position (such position is adjusted by the manufacturer for correct operation). If pressure switch is installed in a different way, monitoring errors may occur due to the influence of mass of the movable parts. In this case additional adjustment of pressure switch using reference manometer is required.

Pressure switches can be assembled into block units (e.g, in the case if upper and lower pressure limits control is required).

A

B

8080

90

1

A

B

10480

90

1C

Page 4: Pressure switches DRD, DRD-N, DRD-T - series diaphragm typetermobrest.net/sitefiles/1/5/35/all6_06_eng.pdf · 2018. 6. 28. · 99 Pic. 5. Overall dimensions of excess pressure switches

100100

Diagram of switching of DRD pressure switches

Under-pressure switches DRD-TA are adjusted only for rise of measured pressure. Therefore they are manufactured only in A version.

Excess pressure DRD-H and under-pressure switches DRD-T are designed for commutation of wattage not exceeding 300 VA (cos ϕ-0,6) at voltage of 220 V for alternating current circuits with frequency of 50 Hz and 70 VA at voltage of 24 V for direct current.

Order example / Pressure switch DRD–120А

Pressure switch DRD–5ТA

Pressure rise

Pressure reduction

Return area

1-21-3

1-21-3

Bri

dgin

g o

f co

nta

cts

P [mbar]

Pressure rise

Pressure reduction

1-21-3

1-21-3

Bri

dg

ing

of

con

tact

s

Set

po

int

val

ue

Type А

Type BReturn area

Set

po

int

val

ue

Page 5: Pressure switches DRD, DRD-N, DRD-T - series diaphragm typetermobrest.net/sitefiles/1/5/35/all6_06_eng.pdf · 2018. 6. 28. · 99 Pic. 5. Overall dimensions of excess pressure switches

101101

1. DRD— series.2. Hyphen.3. Е — pressure switch of electronic type.4. Hyphen.5. Set point upper limit, mbar.6. Т — pressure switch version for simultaneous

control of excess (head) and under-pressure (thrust).

Field of applicationPressure switches of electronic type are complied with TU RB 200020142.025-2000.Pressure switches are used for excess pressure (head) and for under-pressure (thrust)

control of natural, liquefied gas or air in gas supplying systems and ventilation systems. Pressure switches control pressure value and send appropriate signals to automation and control system.

Pressure switches can be assembled into block units (e.g, in the case if upper and lower pressure limits control is required).

Climatic version У3.1 (-30...+60 ОС).

Code structure1 2 3 4 5 6

DRD - Е - х х

Pressure switches DRD-series electronic type

Technical data of pressure switches

Version depending on electric connection: — current output and transistor switch of structure N (npn — «common +»); — current output and transistor switch of structure P (pnp — «common -»); — current and relay output.

Characteristics Value

Temperature of operation medium, ОС –30...+60

Degree of protection per GOST 14254 IP54

Out escape value,cc/h air, max 20

Resource of switchings, min 200 000

Average service time, years, min 10

Page 6: Pressure switches DRD, DRD-N, DRD-T - series diaphragm typetermobrest.net/sitefiles/1/5/35/all6_06_eng.pdf · 2018. 6. 28. · 99 Pic. 5. Overall dimensions of excess pressure switches

102102

Overall dimensions of pressure switches DRD electronic type

Pressure switches DRD - series of electronic type

Housing parts of pressure switch are made of corrosion resistant materials (non-ferrous metal alloys, high-strength plastic, oil-and-gas-resistant rubber). The cover is made of transparent plastic.

№ p/p Characteristics DRD-Е-40 DRD-Е-100 DRD-Е-1000 DRD-Е-6000 DRD-Е-70Т

1 Lower set limit of pressure 0,5 mbar 5 mbar 0,05 bar 0,5 bar -70 mbar

2 Upper set limit of pressure 40 mbar 100 mbar 1 bar 6 bar 70 mbar

3 Operating pressure, max 60 mbar 1,50 mbar 1,5 bar 9 bar 105 mbar

4 Operating spread, % fromupper set limit, max ±10

5 Return area, % from upperset limit, max ±5

6 Weight, kg, max 0,45

Page 7: Pressure switches DRD, DRD-N, DRD-T - series diaphragm typetermobrest.net/sitefiles/1/5/35/all6_06_eng.pdf · 2018. 6. 28. · 99 Pic. 5. Overall dimensions of excess pressure switches

103103

Order of mounting and operation1. Safety requirements during mounting and exploitation according to GOST 12.2.063.2. Before mounting it is necessary to clean supplying pipeline from impurities. 3. Installation of pressure switch of electronic type is possible both on vertical and horizontal pipelines. To

avoid ingress of moisture and steam condensate inside the switch it is also recommended to install the switch with its gland entrance facing downwards..

4. For thread sealing between the pipeline and the housing of pressure switch, it is recommended to use fluoroplastic sealing tape or similar sealing material.

5. Electric mounting /dismounting of the switch should be conducted only when the switch is de-energized.6. Pressure switches of electronic type are connected to gas system by threaded (G¼) holes A and B. If

pressure is supplied through hole А, hole В is to be closed by plug 1, and vice versa.7. Actuation pressure value is set by adjustment knob according to the information scale.8. Actuation pressure can be set more precisely using a standard manometer.9. Electric wires are connected to sensor contacts according to the schemes below mentioned (Picture 23-6).

Connection should be made according to color marking of cable wires. Pressure switches of electronic type have electronic indication devices:— current ouput and transistor switch of structure N (npn — «common +»);— current ouput and transistor switch of structure P (pnp — «common -»);— current and relay sensor.Actuation of pressure switch is monitored by indicator (LED) designed in pressure switch. Indicator turns green

if pressure is lower than actuation pressure (set point pressure). Indicator turns red if pressure is equal or exceeds set point pressure.

10. Pressure switches can be assembled into block units (e.g, in the case if upper and lower pressure limits control is required).

Color marking of cable wires:1 — beige;2 — blue;3 — pink;4 — white;5 — yellow;6 — green.

Pic. Schemes of connection of pressure switches of electronic type а) — current ouput and transistor switch of structure "N" (npn — «common +»); б) — current ouput and transistor switch of structure "P" (pnp — «common -»); в) — current and relay output.

б)

в)

а)

DRD-Е-...

Actuationsetting

Actuation displaying

« »Green

« »Red

24 V DC

Iout.3

2

1

NPN output5

A4...20 mA

DRD-Е-...

Actuationsetting

Actuation displaying

« »Green

« »Red

24 V DC

Iout.3

2

1

PNP output6

RнA4...20 mA

DRD-Е-...

Actuationsetting

Actuation displaying

« »Green

« »Red

24 VDC

Iout.3

2

1

5

4

6

Relayoutput

A4...20 mA

Page 8: Pressure switches DRD, DRD-N, DRD-T - series diaphragm typetermobrest.net/sitefiles/1/5/35/all6_06_eng.pdf · 2018. 6. 28. · 99 Pic. 5. Overall dimensions of excess pressure switches

104104

Characteristics Value

Supply voltage (24±6) V

Consumption current, max 50 mА

Current variation range for current output 4...20 mА(4 mА — lower limit set point;20 mА — upper limit set point)

Commutated current for transistor switch, max 150 mА

Commutated data for relay output:

Commutated power, max 150 W (at 68 V DC;625 VA (at 220 V, 50 Hz).

Commutated current, max 5 А

Technical data of pressure switches of electronic type

Order example for pressure switch of electronic type with upper limit of set point 4000 Pa (40 mbar), designed for excess pressure control with current and relay output:

Pressure switch DRD-Е-40 (current and relay output).

Order example for pressure switch of electronic type with upper limit of set point 7000 Pa (70 mbar), designed for excess and under-pressure control with current output and transistor switch of structure N (NPN output):Pressure switch DRD-Е-70 (current output and transistor switch of structure N).

Page 9: Pressure switches DRD, DRD-N, DRD-T - series diaphragm typetermobrest.net/sitefiles/1/5/35/all6_06_eng.pdf · 2018. 6. 28. · 99 Pic. 5. Overall dimensions of excess pressure switches

105105

Pressure switches DRD-series of electronic type (pressure up to 16 bar)

Characteristics Value

Type of pressure controlled Excess pressure

Max. pressure controlled 16 bar (1600 kPa)

Connection size G1/4''

Information output On digital 4-digit indicator

Power supply of pressure switch (24±6) V DC

Output signal 4...20 mA

Interface RS-485

Technical characteristics of pressure switches of electronic type (pressure up to 16 bar)

Order example of pressure switch of electronic type for max. inlet pressure 16 bar:Pressure switch DRD-16

Field of applicationPressure switches of electronic type are

manufactured accordingly to the ТУ РБ 200020142.025-2000.

Pressure switches are applied for excess pressure (head) control of natural, liquefied gas or air in gas supplying systems and ventilation systems. Pressure switches control pressure value and send appropriate signals to automation and control system

Climatic version: –30...+40 ОС