1 European Code of Conduct for Data Centre Presentation of the Awards 2016 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport

Transcript of Presentation DC CoC Awards 2016 - Energy...Presentation of the Awards 2016 Paolo Bertoldi European...

Page 1: Presentation DC CoC Awards 2016 - Energy...Presentation of the Awards 2016 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport The Code of Conduct for Data

1

European Code of Conductfor Data Centre

Presentation of the Awards 2016

Paolo Bertoldi

European Commission

DG JRC

Institute for Energy and Transport

Page 2: Presentation DC CoC Awards 2016 - Energy...Presentation of the Awards 2016 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport The Code of Conduct for Data

The Code of Conduct for Data CentreResults

• European Programme to improve energy efficiency in data centre

• Started in 2008

• 119 Companies registered as Participants

• 291 Data centres approved as Participant

• 243 Endorsers

Page 3: Presentation DC CoC Awards 2016 - Energy...Presentation of the Awards 2016 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport The Code of Conduct for Data

3

The winners of the Data Centre Code of Conduct 20133

5 Winners

- Data Centre Participants: 4 winners

- Corporate Winner: 1 Winner

Page 4: Presentation DC CoC Awards 2016 - Energy...Presentation of the Awards 2016 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport The Code of Conduct for Data

And thewinners

are…

Page 5: Presentation DC CoC Awards 2016 - Energy...Presentation of the Awards 2016 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport The Code of Conduct for Data

5

Winners of the Award 2016

Data Centre Participants

Page 6: Presentation DC CoC Awards 2016 - Energy...Presentation of the Awards 2016 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport The Code of Conduct for Data

6

b<>com Institute of Research & Technology in Rennes/France

• On-site single step 20kV to 400V conversion. 200kVA datacenter capacity. Modular UPS.

• Underground concrete structure of the DC used as a natural heat drain.

• In-raw CRACs system. No plenum, no raised floor. Power, fiber, chilling pipes run from the ceiling.

• Raised cold aisle temperature set point : 25°C

• 10..14°C chilled water, variable speed fans & water pumps.

• High efficiency Heat recovery from chilled water return path provides heating of the labs facility.

Page 7: Presentation DC CoC Awards 2016 - Energy...Presentation of the Awards 2016 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport The Code of Conduct for Data

7

• Cold Aisle Containment with automatic closing

doors

• Cost effective Corex (fire resistant) blanking

panels – provided free of charge to all customers

• Comprehensive control strategy for cooling

system using sensor average temperatures and

supply & return temperatures on cooling system

to alter fan and pump speeds on indoor and

outdoor equipment to optimise free cooling

• Replacement of external cooling plant for energy

efficiency

• Migration of UPS batteries to separate enclosures

to increase operating temperature of UPS and

electrical switchgear

Six Degrees Group Energy Efficient Solutions, Birmingham (UK)

Page 8: Presentation DC CoC Awards 2016 - Energy...Presentation of the Awards 2016 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport The Code of Conduct for Data

8

FCO Services Milton Keynes DC, UK• The system was designed to support an average 1.1 PUE

performance. During winter mode the solution should perform to

incredible PUE figures of 1.06.

• Modular, scalable power and cooling architecture that allows

deployment as needed. This is the crucial element for improving data

centre efficiency.

• The implementation of modern energy efficient cooling technologies

reduces our operational energy overhead and will have a surprising

contribution to data centre energy savings.

• The bespoke dual 12mL x 3.5mW x 3.5mH modular pods combined

with a “link” corridor is designed supported 22 equipment racks with

1.2m front and 875mm rear rack clearance. Once inside the solutions

looks and feels like a conventional bricks and mortar design.

• The solution was designed to support “pay as you grow” capability.

This was fulfilled through the deployment of modular and scalable

UPS and cooling technology delivering incremental growth.

• We have maximised the use of space in order to reduce the modular

data centre footprint.

• Use of free air evaporative cooling for the data centre reduces power

consumption.

Page 9: Presentation DC CoC Awards 2016 - Energy...Presentation of the Awards 2016 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport The Code of Conduct for Data

9

Resilience Centre Luxembourg South (KAYL): Key design criteria

• ISO 14001 and ISO 50001

• 100% of electricity certified from renewable sources

(hydroelectric power plants)

• Solar panels with photovoltaic cells

• Reuse energy with heat pumps for offices (2.000 m²) within

the Datacentre

• Reuse energy with heat pumps for offices (3.000m²) for

another adjacent building

• Serial Free Chilling with hybrid cooling towers

• Rainwater recycling system (300 m³ rainwater tanks) for

hybrid cooling towers

• High technology for chillers (COP 12 at partial load) with

magnetic bearings compressor

• Cold Aisle Containment

• Frequency converter drives for fans, CRAH and pumps

• PUE real time monitoring

• Modular and scalable capacity components

• Power on demand

Page 10: Presentation DC CoC Awards 2016 - Energy...Presentation of the Awards 2016 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport The Code of Conduct for Data

10

Winner of the Award 2016

Category Corporate Participant

Page 11: Presentation DC CoC Awards 2016 - Energy...Presentation of the Awards 2016 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport The Code of Conduct for Data

11

Energy efficiency solutions in Atman DC• Online efficiency monitoring using SCADA

• Atman has developed its own environmental parameters monitoring using SCADA. Instant information and alerts

from SCADA enable Atman’s personnel to react immediately and fine-tune electrical and mechanical devices in order

to maximize energy efficiency.

• Free cooling (direct and indirect)

• Atman is taking advantage of direct free cooling solutions in their DC facilities where flexible approach to

environmental conditions is allowed.

• In data-rooms which require strict humidity and temperature control Atman uses precision free cooling systems.

• Set points recommended by ASHRAE classes A1-A4: 18 - 27 ºC

• In Atman we encourage our customers to allow flexible set points which guarantee low PUE.

• Sealed racks and isles

• Atman’s staff regularly monitors data-rooms against proper and optimal use of cooling. Hot-spots, empty rack-slots,

reverse fans, etc. are subject to immediate corrections. This activity is backed by appropriate provisions in contracts.

• Vendors – endorsers

• When possible, Atman selects their vendors from registered Code of Conduct Data Centre endorsers (Schneider

Electric, Emerson Network Power, Stulz, Socomec, and others).

Page 12: Presentation DC CoC Awards 2016 - Energy...Presentation of the Awards 2016 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport The Code of Conduct for Data

12

Atman data centre: F3

Raised floor area: 1300 m2 net

Page 13: Presentation DC CoC Awards 2016 - Energy...Presentation of the Awards 2016 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport The Code of Conduct for Data

13

Atman data centre: F4

Raised floor area: 1000 m2 net

Page 14: Presentation DC CoC Awards 2016 - Energy...Presentation of the Awards 2016 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport The Code of Conduct for Data

14

Atman data centre: F5

Raised floor area: 1400 m2 net

Page 15: Presentation DC CoC Awards 2016 - Energy...Presentation of the Awards 2016 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport The Code of Conduct for Data

15

Atman data centre: Warsaw 2 (formerly Thinx)

Raised floor area: 2100 m2 net

Page 16: Presentation DC CoC Awards 2016 - Energy...Presentation of the Awards 2016 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport The Code of Conduct for Data

Thank you for your attention

[email protected]

http://iet.jrc.ec.europa.eu/energyefficiency/ict-codes-conduct/data-centres-energy-efficiency/