Preliminary results of the multipacting measurements in Bd.181
9
Preliminary results of the multipacting measurements in Bd.181
description
Preliminary results of the multipacting measurements in Bd.181. Principle. Measurement at 187.73 MHz 60 s power sweep from -25 dBm to -5 dBm. Measurement at 223.38 MHz 60 s power sweep from -40 dBm to 0 dBm. - PowerPoint PPT Presentation
Transcript of Preliminary results of the multipacting measurements in Bd.181
Preliminary results of the multipacting measurements in Bd.181
Principle
Measurement at 187.73 MHz60 s power sweep from -25 dBm to -5 dBm
Measurement at 223.38 MHz60 s power sweep from -40 dBm to 0 dBm
Measurement at 130.48 MHz60 s power sweep from -25 dBm to -10 dBm
variable magnetic fields
Summary
• All recent results basically are the same like the results of former experiments
• No change of behavior at different frequencies so far
• Magnetic field has a huge impact on multipacting which also could be seen in former experiments