Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science...
-
Upload
hugh-sutton -
Category
Documents
-
view
228 -
download
0
Transcript of Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science...
![Page 1: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/1.jpg)
Precision Measurement of GE
p/GMp with BLAST
Chris Crawford
MIT Laboratory for Nuclear Science
Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao, Hauke Kolster, Jason Seely, Tim Smith, Vitaliy Ziskin, and the BLAST Collaboration
![Page 2: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/2.jpg)
Outline
Introduction and Motivation» Theoretical calculations
Existing Measurements» Rosenbluth technique » Recoil proton polarization (FPP)» Super Rosenbluth
BLAST Experiment» Asymmetry super-ratio method» Polarized beam, polarized targets, detectors» Projected Results
![Page 3: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/3.jpg)
Introduction
GE,GM fundamental quantities describing charge/magnetization in the nucleon
Test of QCD based calculations and models
Provide basis for understanding more complex systems in terms of quarks and gluons
![Page 4: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/4.jpg)
Elastic Scattering
Kinematics
Mott Cross Section
Form Factor
Dipole Form Factor
![Page 5: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/5.jpg)
Rosenbluth Separation
Elastic e-p cross section
At fixed Q2, fit dσ/dΩ vs. tan2(θ/2)» Measurement of absolute cross section
» Dominated by either GE or GM
![Page 6: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/6.jpg)
Unpolarized World Data
![Page 7: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/7.jpg)
Polarization Transfer
Recoil proton polarization
Focal Plane Polarimeter» recoil proton scatters
off secondary 12C target» Pt, Pl measured from
φ distribution » Pb, and analyzing power
cancel out in ratio
![Page 8: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/8.jpg)
World Data
Unpolarized Data Polarization Transfer
» Milbrath et al. (BATES) 1999
» Jones et al. (JLAB), 2000
» Dieterich et al. (MAMI), 2001
» Gayou et al. (JLAB), 2002
Super-Rosenbluth» JLab Hall A, preliminary
results expected soon
![Page 9: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/9.jpg)
Super Rosenbluth Separation
![Page 10: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/10.jpg)
Theory†
Direct QCD calculations» pQCD scaling at high Q2
» Lattice QCDMeson Degrees of Freedom
» Vector Meson Dominance (VMD), Lomon 2002» Dispersion analysis, Höhler et al. 1976» VMD + Chiral Perturbation Theory, Mergel et al. 1996
QCD based quark models» CQM, Frank et al. 1996» Soliton Model, Holzwarth 1996» Cloudy bag, Lu et al. 1998
†Nucleon Electromagnetic Form Factors, Haiyan Gao, Int. J. of Mod. Phys. E, 12, No. 1, 1-40(Review) (2003)
![Page 11: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/11.jpg)
QCD Calculations
Perturbative QCD» diverges at low Q2
» F2/F1 scaling
Lattice QCD» must extrapolate to
physical pion mass
» quenched calculations
![Page 12: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/12.jpg)
Meson Based Models
Vector Meson Dominance Dispersion Analysis
![Page 13: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/13.jpg)
Constituent Quark Models
Relativistic CQMSoliton ModelCloudy Bag Model
Models in closest agreement with recent JLab results:
![Page 14: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/14.jpg)
Form Factor Ratio @ BATES
New technique: polarized beam and target» exploits unique features of BLAST» different systematics
» insensitive to Pb and Pt
Q2 = 0.07 – 0.9 (GeV/c) 2 » overlap with JLab data
and RpEX (future exp.at Bates to measure rp)
![Page 15: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/15.jpg)
Asymmetry Super-ratio Method
Polarized cross section
Super-ratio
![Page 16: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/16.jpg)
W.H. Bates Accelerator Facility
![Page 17: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/17.jpg)
BLAST Collaboration
R. Alarcon, E. Geis, J. Prince, B. Tonguc, A. Young
Arizona State University
J. Althouse, C. D’Andrea, A. Goodhue, J. Pavel, T. Smith,
Dartmouth College
T. Akdogan, W. Bertozzi, T. Botto, M. Chtangeev, B. Clasie, C. Crawford, A. Degrush, K. Dow, M. Farkhondeh, W. Franklin, S. Gilad,
D. Hasell, E. Ilhoff, J. Kelsey, H. Kolster, A. Maschinot, J. Matthews, N. Meitanis,
R. Milner, R. Redwine, J. Seely, S.Sobczynski, C. Tschalaer, E. Tsentalovich,
W. Turchinetz, Y. Xiao, H. Xiang, C. Zhang, V. Ziskin, T. Zwart
Massachusetts Institute of TechnologyBates Linear Accelerator Center
D. Dutta, H. Gao, W. Xu
Duke University
J. Calarco, W. Hersman, M. Holtrop, O. Filoti, P. Karpius, A. Sindile, T. Lee
University of New Hampshire
J. Rapaport
Ohio University
K. McIlhany, A. Mosser
United States Naval Academy
J. F. J. van den Brand, H. J. Bulten, H. R. Poolman
Vrije Universitaet and NIKHEF
W. Haeberli, T. Wise
University of Wisconsin
![Page 18: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/18.jpg)
Polarized Beam and Target
Stored electron beam (80 mA) Eb: 0.27–1.1 GeV Pb: 0.70
1H / 2D target (ABS) L: 1.0×1032/cm2 s Pt: 0.50
3He target L: 1.2×1033/cm2 s Pt: 0.50
![Page 19: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/19.jpg)
Compton Polarimeter
Polarization about 0.70 typical Statistical precision of
measurements governed mostly by signal-to-background ratio. Typical precision of 1-2% per hour.
Systematic errors estimated at 5% level presently. Working on reducing these through improved analysis of energy spectrum.
Full photon energy spectrum measured as function of laser helicity and for background
Polarization measurements made at currents up to 130 mA. Signal to background ratio worsens at high currents but still tractable.
![Page 20: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/20.jpg)
Atomic Beam Source
Standard technologyDissociator & nozzle2 sextupole systems3 RF transitions
1
3
2
4nozzle
6-pole
1
2MFT (2->3)
1
3
6-pole
1Spin State Selection:
![Page 21: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/21.jpg)
ABS Layout
![Page 22: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/22.jpg)
ABS Specifications
Cell geometry: cylindrical 15mm × 400mmCell coating: DrifilmCell temperature: T=80KTarget thickness: t=4.4×1013 cm-2 (H) Polarization: Pz = 0.59 (H), 0.78 (D)
Holding field: B=3mT (H), 35mT (D)
![Page 23: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/23.jpg)
Ion polarimeter
Ions produced by electron beam inside the storage cell
are extracted and accelerated by electrostatic lenses. The
spherical deflector directs ions into the polarimeter arm. The
Wien Filter provides mass separation, and nuclear
reaction with large analyzing power is used to measure
nuclear polarization.
Currently, the tritium target is not installed yet, and Ion
Polarimeter is used as a mass spectrometer.
![Page 24: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/24.jpg)
Laser Driven Source (LDS)
Optical pumping& Spin Exchange
Spincell designTarget and
PolarimeterResults
![Page 25: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/25.jpg)
Spin-Exchange Optical pumping
![Page 26: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/26.jpg)
LDS Experimental Setup
![Page 27: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/27.jpg)
LDS Performance
Current Status» Flux: 1.1×1018 atoms/s» Atomic fraction: 0.56» Polarization: 0.37
Improvements» Diamond coating instead of drifilm» Double dissociator» Electro-Optic Modulator (EOM)
![Page 28: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/28.jpg)
Detector Package
BLAST TorroidTOF ScintillatorsČerenkov DetectorsWire ChambersNeutron Bars, LADSSoftware
![Page 29: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/29.jpg)
Detector Requirements» definition of the momentum transfer vector
» optimize statistics
» polarized targets: Atomic Beam & Laser Driven Sources
» simultaneous A-measurements
» e/p/n/ separation
NeL
Large , beam current, luminosity, polarization
Coil shape 1 m diameter in target region BLAST field = 0 at targetB-gradients 50 mG/cm
Symmetric Detector
()e 2 , e mrad, z 1 cm
PID
![Page 30: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/30.jpg)
BLAST Toroid
![Page 31: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/31.jpg)
Detector Subframe
![Page 32: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/32.jpg)
TOF Scintillators
timing resolution: σ=245 psADC spectrumcoplanarity cuts
![Page 33: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/33.jpg)
Čerenkov Detectors
1 cm thick aerogel tiles Refractive index 1.02-1.03 White reflective paint 80-90 % efficiency
5" PMT's, sensitive to 0.5 Gauss Initial problems with B field Required additional shielding 50% efficiency without shielding
![Page 34: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/34.jpg)
Wire Chambers
2 sectors × 3 chambers 954 sense wires resolution 200μ signal to noise 20:1
![Page 35: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/35.jpg)
Software
BLASTmc – Monte Carlo using Geant321BlastLib2 – recon library based on ROOT
» integrated on-line display » and offline reconstruction
CODA – data acquisitionEPICS – slow controls
![Page 36: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/36.jpg)
Reconstruction Steps
Scintillators» timing, calibration
Wire chamber» hits, stubs, segments
» link, track fit
PID, DST
![Page 37: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/37.jpg)
Tracking Resolution
![Page 38: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/38.jpg)
Radiative Corrections
MASCARAD code» A. Afanasev et al., Phys.Rev.D 64,113009
» Covariant calculation with no cutoff parameter
» small corrections (<1%) to asymmetry
![Page 39: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/39.jpg)
Cross Section
![Page 40: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/40.jpg)
Projected Results
Statistics» A1, A2
Systematics
» θ*1, θ*
2
Δp, Δθ, Δβ
Errors are minimized as a function of β (target spin angle)
![Page 41: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,](https://reader036.fdocuments.us/reader036/viewer/2022081421/56649e9f5503460f94ba0cfc/html5/thumbnails/41.jpg)
Conclusion
The super-ratio method exploits unique characteristics of the BLAST detector
This is the first measurement of μGEp/GM
p with polarized beam and target
An important complement to JLab data at higher Q2 values
If in doubt, take a RATIO…