Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science...

41
Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao, Hauke Kolster, Jason Seely, Tim Smith, Vitaliy Ziskin, and the BLAST

Transcript of Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science...

Page 1: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Precision Measurement of GE

p/GMp with BLAST

Chris Crawford

MIT Laboratory for Nuclear Science

Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao, Hauke Kolster, Jason Seely, Tim Smith, Vitaliy Ziskin, and the BLAST Collaboration

Page 2: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Outline

Introduction and Motivation» Theoretical calculations

Existing Measurements» Rosenbluth technique » Recoil proton polarization (FPP)» Super Rosenbluth

BLAST Experiment» Asymmetry super-ratio method» Polarized beam, polarized targets, detectors» Projected Results

Page 3: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Introduction

GE,GM fundamental quantities describing charge/magnetization in the nucleon

Test of QCD based calculations and models

Provide basis for understanding more complex systems in terms of quarks and gluons

Page 4: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Elastic Scattering

Kinematics

Mott Cross Section

Form Factor

Dipole Form Factor

Page 5: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Rosenbluth Separation

Elastic e-p cross section

At fixed Q2, fit dσ/dΩ vs. tan2(θ/2)» Measurement of absolute cross section

» Dominated by either GE or GM

Page 6: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Unpolarized World Data

Page 7: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Polarization Transfer

Recoil proton polarization

Focal Plane Polarimeter» recoil proton scatters

off secondary 12C target» Pt, Pl measured from

φ distribution » Pb, and analyzing power

cancel out in ratio

Page 8: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

World Data

Unpolarized Data Polarization Transfer

» Milbrath et al. (BATES) 1999

» Jones et al. (JLAB), 2000

» Dieterich et al. (MAMI), 2001

» Gayou et al. (JLAB), 2002

Super-Rosenbluth» JLab Hall A, preliminary

results expected soon

Page 9: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Super Rosenbluth Separation

Page 10: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Theory†

Direct QCD calculations» pQCD scaling at high Q2

» Lattice QCDMeson Degrees of Freedom

» Vector Meson Dominance (VMD), Lomon 2002» Dispersion analysis, Höhler et al. 1976» VMD + Chiral Perturbation Theory, Mergel et al. 1996

QCD based quark models» CQM, Frank et al. 1996» Soliton Model, Holzwarth 1996» Cloudy bag, Lu et al. 1998

†Nucleon Electromagnetic Form Factors, Haiyan Gao, Int. J. of Mod. Phys. E, 12, No. 1, 1-40(Review) (2003)

Page 11: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

QCD Calculations

Perturbative QCD» diverges at low Q2

» F2/F1 scaling

Lattice QCD» must extrapolate to

physical pion mass

» quenched calculations

Page 12: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Meson Based Models

Vector Meson Dominance Dispersion Analysis

Page 13: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Constituent Quark Models

Relativistic CQMSoliton ModelCloudy Bag Model

Models in closest agreement with recent JLab results:

Page 14: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Form Factor Ratio @ BATES

New technique: polarized beam and target» exploits unique features of BLAST» different systematics

» insensitive to Pb and Pt

Q2 = 0.07 – 0.9 (GeV/c) 2 » overlap with JLab data

and RpEX (future exp.at Bates to measure rp)

Page 15: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Asymmetry Super-ratio Method

Polarized cross section

Super-ratio

Page 16: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

W.H. Bates Accelerator Facility

Page 17: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

BLAST Collaboration

R. Alarcon, E. Geis, J. Prince, B. Tonguc, A. Young

Arizona State University

 J. Althouse, C. D’Andrea, A. Goodhue, J. Pavel, T. Smith,

Dartmouth College

T. Akdogan, W. Bertozzi, T. Botto, M. Chtangeev, B. Clasie, C. Crawford, A. Degrush, K. Dow, M. Farkhondeh, W. Franklin, S. Gilad,

D. Hasell, E. Ilhoff, J. Kelsey, H. Kolster, A. Maschinot, J. Matthews, N. Meitanis,

R. Milner, R. Redwine, J. Seely, S.Sobczynski, C. Tschalaer, E. Tsentalovich,

W. Turchinetz, Y. Xiao, H. Xiang, C. Zhang, V. Ziskin, T. Zwart

Massachusetts Institute of TechnologyBates Linear Accelerator Center

D. Dutta, H. Gao, W. Xu

Duke University

J. Calarco, W. Hersman, M. Holtrop, O. Filoti, P. Karpius, A. Sindile, T. Lee

University of New Hampshire 

J. Rapaport

Ohio University 

K. McIlhany, A. Mosser

United States Naval Academy

 J. F. J. van den Brand, H. J. Bulten, H. R. Poolman

Vrije Universitaet and NIKHEF 

W. Haeberli, T. Wise

University of Wisconsin

Page 18: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Polarized Beam and Target

Stored electron beam (80 mA) Eb: 0.27–1.1 GeV Pb: 0.70

1H / 2D target (ABS) L: 1.0×1032/cm2 s Pt: 0.50

3He target L: 1.2×1033/cm2 s Pt: 0.50

Page 19: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Compton Polarimeter

Polarization about 0.70 typical Statistical precision of

measurements governed mostly by signal-to-background ratio. Typical precision of 1-2% per hour.

Systematic errors estimated at 5% level presently. Working on reducing these through improved analysis of energy spectrum.

Full photon energy spectrum measured as function of laser helicity and for background

Polarization measurements made at currents up to 130 mA. Signal to background ratio worsens at high currents but still tractable.

Page 20: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Atomic Beam Source

Standard technologyDissociator & nozzle2 sextupole systems3 RF transitions

1

3

2

4nozzle

6-pole

1

2MFT (2->3)

1

3

6-pole

1Spin State Selection:

Page 21: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

ABS Layout

Page 22: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

ABS Specifications

Cell geometry: cylindrical 15mm × 400mmCell coating: DrifilmCell temperature: T=80KTarget thickness: t=4.4×1013 cm-2 (H) Polarization: Pz = 0.59 (H), 0.78 (D)

Holding field: B=3mT (H), 35mT (D)

Page 23: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Ion polarimeter

Ions produced by electron beam inside the storage cell

are extracted and accelerated by electrostatic lenses. The

spherical deflector directs ions into the polarimeter arm. The

Wien Filter provides mass separation, and nuclear

reaction with large analyzing power is used to measure

nuclear polarization.

Currently, the tritium target is not installed yet, and Ion

Polarimeter is used as a mass spectrometer.

Page 24: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Laser Driven Source (LDS)

Optical pumping& Spin Exchange

Spincell designTarget and

PolarimeterResults

Page 25: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Spin-Exchange Optical pumping

Page 26: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

LDS Experimental Setup

Page 27: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

LDS Performance

Current Status» Flux: 1.1×1018 atoms/s» Atomic fraction: 0.56» Polarization: 0.37

Improvements» Diamond coating instead of drifilm» Double dissociator» Electro-Optic Modulator (EOM)

Page 28: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Detector Package

BLAST TorroidTOF ScintillatorsČerenkov DetectorsWire ChambersNeutron Bars, LADSSoftware

Page 29: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Detector Requirements» definition of the momentum transfer vector

» optimize statistics

» polarized targets: Atomic Beam & Laser Driven Sources

» simultaneous A-measurements

» e/p/n/ separation

NeL

Large , beam current, luminosity, polarization

Coil shape 1 m diameter in target region BLAST field = 0 at targetB-gradients 50 mG/cm

Symmetric Detector

()e 2 , e mrad, z 1 cm

PID

Page 30: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

BLAST Toroid

Page 31: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Detector Subframe

Page 32: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

TOF Scintillators

timing resolution: σ=245 psADC spectrumcoplanarity cuts

Page 33: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Čerenkov Detectors

1 cm thick aerogel tiles Refractive index 1.02-1.03 White reflective paint 80-90 % efficiency

5" PMT's, sensitive to 0.5 Gauss Initial problems with B field Required additional shielding 50% efficiency without shielding

Page 34: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Wire Chambers

2 sectors × 3 chambers 954 sense wires resolution 200μ signal to noise 20:1

Page 35: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Software

BLASTmc – Monte Carlo using Geant321BlastLib2 – recon library based on ROOT

» integrated on-line display » and offline reconstruction

CODA – data acquisitionEPICS – slow controls

Page 36: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Reconstruction Steps

Scintillators» timing, calibration

Wire chamber» hits, stubs, segments

» link, track fit

PID, DST

Page 37: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Tracking Resolution

Page 38: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Radiative Corrections

MASCARAD code» A. Afanasev et al., Phys.Rev.D 64,113009

» Covariant calculation with no cutoff parameter

» small corrections (<1%) to asymmetry

Page 39: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Cross Section

Page 40: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Projected Results

Statistics» A1, A2

Systematics

» θ*1, θ*

2

Δp, Δθ, Δβ

Errors are minimized as a function of β (target spin angle)

Page 41: Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Ricardo Alarcon, John Calarco, Ben Clasie, Haiyan Gao,

Conclusion

The super-ratio method exploits unique characteristics of the BLAST detector

This is the first measurement of μGEp/GM

p with polarized beam and target

An important complement to JLab data at higher Q2 values

If in doubt, take a RATIO…