Practical Design Requirements For

New Lyophilization Equipment

PDA Israeli Chapter

Lyophilization & sterilization conference

13/11/2017

Yossi Shapira

Teva Pharm. Ind.

Freeze Drying Expert

Page 2: Practical Design Requirements For New Lyophilization Equipmentpdaisrael.co.il/131117/PDA Yossi Shapira 2 new... · Practical Design Requirements For New Lyophilization Equipment PDA

2

• FDA comment: Shelf temp. Mapping: :

"Inadequate empty chamber shelf temperature and product temperature mapping….. “TCs are typically placed in 4 corners and in center of each shelf.”

“Identify cold and hot spots, variability of 1-2°C between shelves might be expected”.

Test is done in static condition. In dynamic conditions 3-5 degrees difference can be observed between inlet and outlet of diathermic fluid

Not acceptable!!! When lyophilizer is already constructed what can we do with exceeding points? The 4 corners and center point do not represent anything!!!.

• Vendor will increase circulation pump output? Change labyrinth form? Turbulent flow rather than “laminar”?

• Vendor will Change FAT SAT shelves mapping procedures!

Slide Title

Yossi Shapira 11/2017 Yossi Shapira 11/2017

Page 3: Practical Design Requirements For New Lyophilization Equipmentpdaisrael.co.il/131117/PDA Yossi Shapira 2 new... · Practical Design Requirements For New Lyophilization Equipment PDA

3

Shelves Temperature Uniformity

Yossi Shapira 11/2017 Yossi Shapira 11/2017

Page 4: Practical Design Requirements For New Lyophilization Equipmentpdaisrael.co.il/131117/PDA Yossi Shapira 2 new... · Practical Design Requirements For New Lyophilization Equipment PDA

4

Shelves Temperature Uniformity

Yossi Shapira 11/2017 Yossi Shapira 11/2017

Page 5: Practical Design Requirements For New Lyophilization Equipmentpdaisrael.co.il/131117/PDA Yossi Shapira 2 new... · Practical Design Requirements For New Lyophilization Equipment PDA

5

Shelves Temperature Uniformity

Yossi Shapira 11/2017 Yossi Shapira 11/2017

Page 6: Practical Design Requirements For New Lyophilization Equipmentpdaisrael.co.il/131117/PDA Yossi Shapira 2 new... · Practical Design Requirements For New Lyophilization Equipment PDA

6

Shelves Temperature Uniformity

Yossi Shapira 11/2017 Yossi Shapira 11/2017

Page 7: Practical Design Requirements For New Lyophilization Equipmentpdaisrael.co.il/131117/PDA Yossi Shapira 2 new... · Practical Design Requirements For New Lyophilization Equipment PDA

7

Shelves Temperature Uniformity

Yossi Shapira 11/2017 Yossi Shapira 11/2017

Page 8: Practical Design Requirements For New Lyophilization Equipmentpdaisrael.co.il/131117/PDA Yossi Shapira 2 new... · Practical Design Requirements For New Lyophilization Equipment PDA

8

Shelves Temperature Uniformity….

Yossi Shapira 11/2017 Yossi Shapira 11/2017

Page 9: Practical Design Requirements For New Lyophilization Equipmentpdaisrael.co.il/131117/PDA Yossi Shapira 2 new... · Practical Design Requirements For New Lyophilization Equipment PDA

9

Shelves Temperature Uniformity -

Freezing

Yossi Shapira 11/2017 Yossi Shapira 11/2017

Page 10: Practical Design Requirements For New Lyophilization Equipmentpdaisrael.co.il/131117/PDA Yossi Shapira 2 new... · Practical Design Requirements For New Lyophilization Equipment PDA

10

Shelves Temperature Uniformity -

Freezing

Yossi Shapira 11/2017 Yossi Shapira 11/2017

Page 11: Practical Design Requirements For New Lyophilization Equipmentpdaisrael.co.il/131117/PDA Yossi Shapira 2 new... · Practical Design Requirements For New Lyophilization Equipment PDA

11

Shelves Temperature Uniformity -

Drying

Yossi Shapira 11/2017 Yossi Shapira 11/2017

Page 12: Practical Design Requirements For New Lyophilization Equipmentpdaisrael.co.il/131117/PDA Yossi Shapira 2 new... · Practical Design Requirements For New Lyophilization Equipment PDA

12

• FDA Comment: product mapping

“To demonstrate product uniformity and ability to repeat and consistently

manufacture product. Product uniformity is demonstrated through product

temperature mapping and extended sampling/testing of reconstituted

product…. (experiments/runs) are usually performed as engineering runs

since using TC throughout the load is not aseptic”

• Vendors should provide wireless sterilizable vials temperature

mapping sensors, including appropriate SCADA to accumulate

the data. Particularly where ALS (Automatic Loading System)

is used.

Slide Title

Yossi Shapira 11/2017 Yossi Shapira 11/2017

Page 13: Practical Design Requirements For New Lyophilization Equipmentpdaisrael.co.il/131117/PDA Yossi Shapira 2 new... · Practical Design Requirements For New Lyophilization Equipment PDA

13

Determining drying end point- PRT Pressure Rise Test (PRT) is an accurate residual moisture test.

It is measuring chamber’s pressure rise within certain duration ( seconds).

PR Test results are influenced by:

1. Product’s residual moisture

2. Amount of product/ vials/trays in the lyophilizer’s chamber

3. Temperature of the shelf

4. Chamber’s pressure

5. Chamber’s volume

6. Test duration

Pressure Rise Test

Yossi Shapira 11/2017 Yossi Shapira 11/2017

Page 14: Practical Design Requirements For New Lyophilization Equipmentpdaisrael.co.il/131117/PDA Yossi Shapira 2 new... · Practical Design Requirements For New Lyophilization Equipment PDA

14

PR1= 𝑃2−𝑃1

𝑡 (𝑠𝑒𝑐𝑠)

PR(1+30min) = 𝑃2−𝑃1

𝑡 (𝑠𝑒𝑐𝑠) = PR2

PR(1+60mi)n = 𝑃2−𝑃1

𝑡 (𝑠𝑒𝑐𝑠) = PR3

Drying end point is obtained when:

PR1- PR2= PR2- PR3= ~ const.= ~ 0

• Vendors should upgrade PRT algorithm program.

Primary drying end point is not concluded by PRT.

Pressure Rise Test

Yossi Shapira 11/2017 Yossi Shapira 11/2017

Page 15: Practical Design Requirements For New Lyophilization Equipmentpdaisrael.co.il/131117/PDA Yossi Shapira 2 new... · Practical Design Requirements For New Lyophilization Equipment PDA

15

• FDA comment:

“Temperature profile diagrams are useful in determining when primary and

secondary drying have completed.“

“Usually performed as engineering runs since TC using in the load is not

aseptic“.

Slide Title

Yossi Shapira 11/2017 Yossi Shapira 11/2017

Page 16: Practical Design Requirements For New Lyophilization Equipmentpdaisrael.co.il/131117/PDA Yossi Shapira 2 new... · Practical Design Requirements For New Lyophilization Equipment PDA

16

Primary Drying end point determination

Yossi Shapira 11/2017 Yossi Shapira 11/2017

Page 17: Practical Design Requirements For New Lyophilization Equipmentpdaisrael.co.il/131117/PDA Yossi Shapira 2 new... · Practical Design Requirements For New Lyophilization Equipment PDA

17

Determining primary drying end point

determination

Yossi Shapira 11/2017 Yossi Shapira 11/2017

Page 18: Practical Design Requirements For New Lyophilization Equipmentpdaisrael.co.il/131117/PDA Yossi Shapira 2 new... · Practical Design Requirements For New Lyophilization Equipment PDA

18

Primary drying complete should be determined by the Pirani to capacitance

pressure sensors reading difference.

• Vendor should install Pirani and Capacitance pressure sensors at list

lyophilizer‘s chamber

• Vendor will develop an optionally use algoritm for monitoring the

difference between the pirany and capacitance sensor. While

difference is reduced, automatically move to secondary drying

parameters

Primary Drying end point determination

Yossi Shapira 11/2017 Yossi Shapira 11/2017

Page 19: Practical Design Requirements For New Lyophilization Equipmentpdaisrael.co.il/131117/PDA Yossi Shapira 2 new... · Practical Design Requirements For New Lyophilization Equipment PDA

19

FDA comment:

“in equipment qualifications FDA would like to see qualification of

condenser capacity.“

Vendors are quoting average ice thickness on condenser coils: 11- 18mm.

This ice quantity can be accumulated within 5 days/ 24 hours. As can be seen

ice thickness is less important but condensation rate is the important factor.

Vendor should add lyophilization rate!

Condensation rate is influenced by:

1. Heaters strength in Kw,

2. Condenser coil temperaure while sublimation take place.

3. Condenser / chamber passage diameter.

Slide Title

Yossi Shapira 11/2017 Yossi Shapira 11/2017

Page 20: Practical Design Requirements For New Lyophilization Equipmentpdaisrael.co.il/131117/PDA Yossi Shapira 2 new... · Practical Design Requirements For New Lyophilization Equipment PDA

20

Determining condenser capacity

Yossi Shapira 11/2017 Yossi Shapira 11/2017

Page 21: Practical Design Requirements For New Lyophilization Equipmentpdaisrael.co.il/131117/PDA Yossi Shapira 2 new... · Practical Design Requirements For New Lyophilization Equipment PDA

21

Determining condenser capacity

Yossi Shapira 11/2017 Yossi Shapira 11/2017

Page 22: Practical Design Requirements For New Lyophilization Equipmentpdaisrael.co.il/131117/PDA Yossi Shapira 2 new... · Practical Design Requirements For New Lyophilization Equipment PDA

THANK YOU

Yossi Shapira Teva Pharm. Ind. Freeze Drying Expert

PDA Israeli Chapter