PR - dorot.com · PDF file1 protection coating to EN12944 C4, C5 & C5M. Deluge Pressure...

6
Fire Protection Div. Dorot Fire Protection Division Deluge Pressure Reducing Valves Deluge PR Valves Certification & compliance by design Typical applications Automatic or Manual actuated Fire Suppression Systems Hangars & Airport terminals Flammable Storage Power Generation, Transformer & Transmission Plants Tunnels Petrochemical, Oil & Gas Installations Onshore-offshore Mining Model 68 DE\ EL\ PR Electrically Actuated, Remote-Reset, Pressure Reducing, Deluge Valve ANSI FCI 70-2 Class VI seat leakage class UL listed under VLFT category Fire tested to EN ISO 6182-5:2006 SIL 3-4 to IEC 65508/65111 in redundant system configuration Lloyd’s & ABS type approvals Designed for High-pressure (PN25/375psi), high-flow deluge systems Regulating downstream pressure regardless of upstream pressure and flow fluctuations Automatic or manual emergency actuation Hazardous-flammable and explosion classified area fire suppression • Onshore & Offshore, Naval, Industrial, Commercial & Residential fire suppression Features • Superior design featuring exceptionally low pressure losses at high flow rates Simple field adjustable pressure setting with no special tools or system downtime • Low to negligible lifelong maintenance costs thanks to no wetted metallic and mechanical moving parts design Simple, comprised of 3 main parts, no expertise required for maintenance Fresh or Brackish water, seawater and foam Out of the box fully assembled & tested valves • All valves are factory trimmed for both vertical & horizontal installations without modification Extensive valve & trim materials selection and corrosion protection coating to EN12944 C4, C5 & C5M 1

Transcript of PR - dorot.com · PDF file1 protection coating to EN12944 C4, C5 & C5M. Deluge Pressure...

Page 1: PR - dorot.com · PDF file1 protection coating to EN12944 C4, C5 & C5M. Deluge Pressure Reducing Valves Model 68-DE\EL\PR Fire Protection Div. 2 General description and operation modes

Fire Protection Div.

Dorot Fire Protection Division

Deluge Pressure Reducing Valves

Deluge PR Valves

Certification & compliance by design

Typical applications

Automatic or Manual actuated Fire Suppression Systems

Hangars & Airport terminals

Flammable Storage

Power Generation, Transformer & Transmission Plants

Tunnels

Petrochemical, Oil & Gas Installations

CAMERA-READY LOGOTYPE FOR TYPE L AND TYPE R LISTING MARKSThese Marks are registered by Underwriters Laboratories Inc.

The minimum height of the registered trademark symbol ® shall be 3/64 of an inch. When the overall diameter of the UL Mark is less than 3/8 of an inch, the trademark symbol may be omitted if it is not legible to the naked eye.

The font for all letter forms is Helvetica Condensed Black, except for the trademark symbol ®, which isHelvetica Condensed Medium. No other fonts are acceptable.

Please Note:The word "MARINE" should only be used for UL Classified marine products.

200-195D 20M/11/97

Onshore-offshore

Mining

Model 68 DE\ EL\ PR

Electrically Actuated, Remote-Reset, Pressure Reducing, Deluge Valve

• ANSI FCI 70-2 Class VI seat leakage class• UL listed under VLFT category• Fire tested to EN ISO 6182-5:2006• SIL 3-4 to IEC 65508/65111 in redundant system

configuration• Lloyd’s & ABS type approvals

Designed for• High-pressure (PN25/375psi), high-flow deluge systems• Regulating downstream pressure regardless of upstream

pressure and flow fluctuations• Automatic or manual emergency actuation• Hazardous-flammable and explosion classified area fire

suppression• Onshore & Offshore, Naval, Industrial, Commercial &

Residential fire suppression

Features• Superior design featuring exceptionally low pressure

losses at high flow rates• Simple field adjustable pressure setting with no special

tools or system downtime• Low to negligible lifelong maintenance costs thanks to

no wetted metallic and mechanical moving parts design• Simple, comprised of 3 main parts, no expertise required

for maintenance• Fresh or Brackish water, seawater and foam• Out of the box fully assembled & tested valves• All valves are factory trimmed for both vertical &

horizontal installations without modification• Extensive valve & trim materials selection and corrosion

protection coating to EN12944 C4, C5 & C5M1

Page 2: PR - dorot.com · PDF file1 protection coating to EN12944 C4, C5 & C5M. Deluge Pressure Reducing Valves Model 68-DE\EL\PR Fire Protection Div. 2 General description and operation modes

Deluge Pressure Reducing Valves

Model 68-DE\EL\PRFire Protection Div.

2

General description and operation modes

This electrically actuated, remote-reset, pressure reducing deluge valve is designed for fire protection systems controlled by a fire alarm control panel and actuated by a solenoid valve acting as the automatic release device. The basic control valve type used in this deluge system is a direct-sealing elastomeric diaphragm, hydraulically operated control valve engineered specifically for fire protection systems. The system includes a 2/2 way N.C. solenoid as the interface between the fire alarm control panel - monitoring heat, smoke or flames - and the deluge valve.In the standby position, the deluge valve is held closed by the upstream water pressure, trapped in the valve's control chamber. The water pressure enters the control chamber through the priming line ball valve [2], a Y-type strainer [3], a check valve [4] and a T-restrictor [5].Under fire conditions, a fire alarm control panel energizes the 2/2 way N.C. solenoid [9] (or de-energizes the coil of a continuously energized ED 100% normally open solenoid for SIL 3-4 rated systems). This causes the 2/2 way N.C. solenoid [9] to open, allowing the water to begin to drain from the deluge valve’s control chamber through the pressure reducing pilot [10]. The deluge valve opens instantly, regulating to a steady, preset downstream pressure, regardless of upstream pressure or flow rate fluctuations. This allows water to flow into the pipeline and through the open sprinklers over the protected area.Manual emergency actuation is enabled by opening the emergency manual activation valve [6]. When connected through the pressure reducing pilot [10] (optional), manual actuation causes the deluge valve to regulate the downstream pressure regardless of upstream pressure or flow rate fluctuations. If unspecified, the manual activation valve [6] is drained to the atmosphere, thus allowing the deluge valve to open fully. When actuated, the deluge valve opens instantly and allows water to flow into the pipeline and through the open sprinklers over the protected area.Resetting, maintenance and periodic testing instructions must be followed as described in detail in the relevant Dorot DE\EL\PR model's IOM (Installation, Operation & Maintenance) manual.

68-DE\EL-PR

PRV

PRV

PRV

PRV

68-DE\EL-PR

PRV

PRV

PRV

PRV

68-DE\EL-PR

PRV

PRV

PRV

PRV

68-DE\EL-PR

PRV

PRV

PRV

PRV

Manually Actuated

Standby Position Electrically Actuated & Pressure Reducing

Manually Actuated & Pressure Reducing

Water Water

Control(By others)

Sensor Line

Control(By others)

To System

Sensor Line

Control(By others)

Sensor Line

Water To System

To System

Control(By others)

Sensor Line

Water

[6]

[1]

[10]

[2] [3] [4] [5]

[9]

[6]

[1]

[10]

[2] [3] [4] [5]

[9]

[6]

[1]

[10]

[2] [3] [4]

[9]

[5]

[6]

[1]

[10]

[2] [3] [4]

[9]

[5]

To System

Page 3: PR - dorot.com · PDF file1 protection coating to EN12944 C4, C5 & C5M. Deluge Pressure Reducing Valves Model 68-DE\EL\PR Fire Protection Div. 2 General description and operation modes

Deluge Pressure Reducing Valves

Model 68-DE\EL\PR

Typical control trim materials for POG (1) applications

ID Description Material (2)

1 Dorot deluge valve body See Engineering data model (2b)

2 Ball valve SST316

3 Y-Type strainer SST316

4 Check valve SST316

5 T restrictor SST316

6 Manual emergency valve SST316

7 Drip valve SST316

8 Pressure gauge SST

9 2/2 way N.C. solenoid (3) SST316

10 CXPR Pressure reducing pilot SST316

3

(1) Petrochemical, Oil & Gas(2) Refer to material selection guidelines,

Engineering Data - Valves & Control Trims(2b) Basic Valve material options:

Ductile Iron A-536 65-45-12; Cast Steel A-216 WCB;Cast Steel A-352 LCB; Austenitic Stainless Steel A-351/CF8M; Super Duplex 2507; Nickel-Aluminium-Bronze B-148 UNS C95800

(3) Refer to solenoid selection guidelines

4

7

10

8

3

1

2

2

5

6

9

8

Page 4: PR - dorot.com · PDF file1 protection coating to EN12944 C4, C5 & C5M. Deluge Pressure Reducing Valves Model 68-DE\EL\PR Fire Protection Div. 2 General description and operation modes

Deluge Pressure Reducing Valves

Model 68-DE\EL\PRFire Protection Div.

Valve dimensions

Valve 2 (50) 2.5 (65) 3 (80) 4 (100) 6 (150) 8 (200) 10 (250)inch mm inch mm inch mm inch mm inch mm inch mm inch mm

A 9 1/8 230 9 3/16 233 12 3/16 310 14 356 17 3/16 436 20 7/8 530 25 1/8 636B 11 279 11 279 11 279 11 279 11 279 11 279 12 1/2 318C 4 1/2 115 4 5/8 116.5 6 1/8 155 7 178 8 5/8 218 10 3/8 265 12 1/2 318D 8 5/8 217.5 8 5/8 217.5 9 3/16 234 10 3/8 265 11 11/16 297 13 3/16 334 15 1/8 382.5E 7 1/8 180 7 1/8 180 7 5/8 193 8 204 9 5/16 236 10 254 11 280F 3 5/16 85 3 5/8 92.5 4 1/8 105 4 11/16 120 5 7/8 150 7 1/8 180 8 1/2 215G 10 5/8 268 10 5/8 268 12 13/16 324 12 13/16 324 16 1/8 409 18 5/8 472 19 1/2 494

Approx. Weight

Ibs kg Ibs kg Ibs kg Ibs kg Ibs kg Ibs kg Ibs kg33 15 36 16.5 77 35 95 43 176 80 282 128 430 195

* Approximate dimensions

4

CONTROL VALVES

SST

190

CONTROL VALVES

Brass

247

CONTROL VALVES

E

CB

DA

F G

CONTROL VALVES

E

CB

D

A

F G

Optional Upstream Drain Valve

Page 5: PR - dorot.com · PDF file1 protection coating to EN12944 C4, C5 & C5M. Deluge Pressure Reducing Valves Model 68-DE\EL\PR Fire Protection Div. 2 General description and operation modes

Deluge Pressure Reducing Valves

Model 68-DE\EL\PRFire Protection Div.

5

12

Typical system layoutDorot’s DE\EL\PR, electrically actuated, remote-reset, pressure reducing deluge valve is held shut drip-tight in its standby position. When a fire alarm control panel energizes the 2/2 way N.C. solenoid (or de-energizes the coil of a continuously energized ED 100% normally open solenoid for SIL 3-4 rated systems), the deluge valve's control chamber begins to drain through the pressure reducing pilot. The deluge valve opens instantly, regulating to a steady, preset downstream pressure, regardless of upstream pressure or flow rate fluctuations.

Pressure reducing feature

3

3

Electrically actuated, remote reset pressure reducing deluge valve

1

Fire alarm control panel2

CXPR pressure reducing pilot3

Page 6: PR - dorot.com · PDF file1 protection coating to EN12944 C4, C5 & C5M. Deluge Pressure Reducing Valves Model 68-DE\EL\PR Fire Protection Div. 2 General description and operation modes

Deluge Pressure Reducing Valves

Model 68-DE\EL\PRFire Protection Div.

Ed

itio

n 2

4.12

.201

7

6Dorot & Dorot companies worldwide reserve the right to make changes without notice including product specification and configuration, content, description(s), dimensions etc. The Information herein is subject to change without notice. Dorot shall not be held liable for any errors. All rights reserved. © Copyright by Dorot.

Ordering guide

Specification for engineers The deluge valve shall be hydraulically operated, direct elastomeric diaphragm-seal, single chamber weir type. The valve shall consist of three major components: the body, cover and the diaphragm assembly. The diaphragm shall be the only moving part. The diaphragm forms a sealed control chamber in the upper portion of the valve, separating operating pressure from line pressure. Packing glands’ stuffing boxes and dynamic o-ring seals are not permitted and there shall be no shafts, discs, bearings or pistons operating the main valve. No hourglass-shaped disc retainers shall be permitted and no V-type, U-type or other slotted type disc guides shall be used. The valve shall contain a nylon reinforced rubber diaphragm, elastic & resilient through its entire surface without vulcanized radial discs and/or reinforcements. The diaphragm shall not be guided by any shafts or bearings and shall not be in close contact with other valve parts except for its sealing surface. Maintenance, disassembly and reassembly of all the valve’s components shall be made possible on site and in-line, without the need to remove the valve from the line. Standard material valves such as Ductile Iron (ASTM A-536 65-45-12) and Cast Steel (WCB A-216) should be coated with high-built fusion-bonded epoxy (FBE) and a UV protective topcoat conforming to EN12944 C4 & C5 high & very high corrosivity protection grades. Naval quality/very high corrosivity protection grade conforming to EN12944 C5M is available upon request. Other coating standards such as NORSOK or ANSI/NACE as well as coatings for special material valves such as austenitic Stainless Steel (CF8M/ASTM A-316 ) and Nickel Aluminum Bronze (ASTM B-148) can be supplied upon request. The valve should be UL listed under category VLFT for fire protection service.

68 - SS - P - 3 - AN150RF - DE\EL\PR - /PI/HA/...

Model 68 68 Optional add-on

Material UV Upstream drain valve

Dutile Iron - HA Hydraulic alarm loop

Cast Steel CS LS Limit switch

SST316 SS Ex Explosion-proof *

NAB NAB PI Pressure switch

Optional add-on Control function

Indicator rod I End connection standard

Spring P AN15RF ANSI #150 (FF or RF)

Size (inch) 2”-24” AN30RF ANSI #300 (FF or RF)

V Grooved

ISO16 ISO PN16

ISO25 ISO PN25

xxx Other (specify)

Technical data:• Media up to 80°C = 176°F• Elastomers suitable for extreme climates are available

upon request.

Sizes:• Straight Flow: 2”-24”• Angle: 1.5” - 8”

End connections:• Flanged:

ISO PN10, ISO-PN16 & ISO-PN25 ANSI B16.42 Class # 150 and # 300 AS Tables D & E, JIS Additional options available upon request

• Grooved: Sizes: 2”-8”

Pressure rating:• 250 psi for Class #150• 375 psi for Class #300* If explosion-proof accessories are required such as pressure switches or transmitters, please define classification.

UL listed sizes:• Model 68: 2”-10”

Please specify in addition to the above:• Electrical features other than standard (24VDC, IP65/NEMA4)• Control trim material other than standard (Brass/Copper) • Required standards, certifications and approval

Dorot Control Valves www.dorot.come-mail: [email protected]