PPE, Respirators, asbestos, confined spaces, lock out/tag out.
-
Upload
alexia-warner -
Category
Documents
-
view
225 -
download
1
Transcript of PPE, Respirators, asbestos, confined spaces, lock out/tag out.
![Page 1: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/1.jpg)
PPE, Respirators, asbestos, confined spaces, lock out/tag out
![Page 2: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/2.jpg)
Identification of potentialWork Site Safety Hazards
ElectricalFire / ExplosionSlips, Trips and
FallsHorseplayImproper Use of
Hand ToolsLack of Observance
of SurroundingsDrugs and Alcohol
Use
Poor LightingStress, Fitness for
DutyConfined SpacesNoisePPEOther Medical
EmergenciesHousekeeping
![Page 3: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/3.jpg)
Work Site Safety Hazards Sharp objects Slippery surfaces Falling objects Terrain Unstable surfaces Burns Improper lifting
Ergonomic hazards
Pinch points Environmental
(weather, animals, poisonous plants)
Struck-by / Roll Over Public/Other
Contractors Dehydration
![Page 4: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/4.jpg)
Work Place Work Place HazardsHazards
OSHA’s Hierarchy of Controls
![Page 5: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/5.jpg)
Personal Protective Equipment
• 29 CFR 1910.132• “Protective equipment, including personal
protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices…shall be provided, used and maintained whenever it is necessary by reason of hazards of processes or environment… capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.
![Page 6: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/6.jpg)
Personal Protective Equipment
• Protective Clothing• Tyvex versus poly spun • Two suit protocol?• Hoods and boots• Respirator inside of hood• Oversize suits for ease of movement• Reinforce suits with duct tape• Tape wrists to gloves, ankles
![Page 7: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/7.jpg)
Respiratory Protection
• Respirators are the last option after:
– engineering controls
– administrative controls
– work practices
– alternative materials
– other methods
![Page 8: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/8.jpg)
Definition:
“A respirator is a personal device designed to protect the wearer from the inhalation of hazardous atmospheres.” (ANSI Z88.2, 1992)
![Page 9: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/9.jpg)
Exposure Assessment
• know potential airborne hazards
• assume a hazard is present until assessment is complete
• testing to be performed by competent person
![Page 10: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/10.jpg)
Employer Responsibilities
• employees must have proper protection
• employees must be medically fit
• employees must be trained
• required fit testing
• written respiratory protection program
![Page 11: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/11.jpg)
Selection of Respirators
• use only approved respirators
• what you need to know when selecting respirators
• other important factors
![Page 12: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/12.jpg)
Types of Respirators
• air-purifying respirators
– negative-pressure air purifying respirators
– powered air-purifying respirators
• supplied-air respirators
• self-contained breathing apparatus
![Page 13: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/13.jpg)
Respirator Cartridge Color Codes
Atmospheric Contaminants to BeProtected Against Color Assigned1
Acid Gases WhiteHydrocyanic acid gas White with ½ inch green stripe completely around the
canister near the bottomOrganic vapors BlackAmmonia gas GreenAcid gases and ammonia gas Green with ½ inch white stripe around the canister near the bottomCarbon monoxide BlueAcid gases and organic vapors YellowHydrocyanic acid gas and chloropicrin vapor Yellow with ½ inch blue stripe completely around the
canister near the bottomAcid gases, organic vapors, and ammonia gases BrownRadioactive particles, asbestos, lead mold Purple (Magenta)(High Efficiency Particulate Filter)Particles (dusts, fumes, mist, fogs, or smoke) Canister color for contaminant as designated above,in combination with any of the above gases with ½ inch gray stripe completely around the canisteror vapors near the topAll of the above atmospheric contaminants Red with ½ inch gray stripe completely around the canister near the top
1Gray shall not be assigned as the main color for a canister designed to remove acids or vapors.Note: Orange shall be used as a complete body, or stripe color to represent gases not included in this table. The user will need to refer to the canister label to determine the degree of protection the canister will afford. For LEAD particles or fume the cartridge for PARTICLES is needed. It has a high-efficiency HEPA filter which is purple (magenta).
![Page 14: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/14.jpg)
Protection Factors
• contaminants inside the respirator
• ratio of contaminant inside to outside
• who determines protection factor
![Page 15: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/15.jpg)
Type of Respirator APF
½ mask air-purifying (HEPA filter) 10loose-fitting hood or helmet powered air-purifying (HEPA filter) 25hood or helmet supplied-air - continuous flow mode 25tight-fitting powered air-purifying (HEPA) 50full face piece air-purifying (HEPA) 50½ mask or full face piece supplied air - continuous flow mode 50½ mask supplied air in pressure-demand mode 1,000full face piece supplied air in pressure-demand mode 2,000full face piece SCBA in pressure-demand mode >2,000
*Assigned Protection Factor
Protection Factors
![Page 16: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/16.jpg)
Respirator Fit
• initial fit test and re-testing requirement• types of fit tests
– qualitative• depends upon ability of wearer to detect
irritant inside respirator
– quantitative• substance measured inside & outside of
respirator
![Page 17: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/17.jpg)
Fit Checks
• rationale for the fit check
• negative pressure check– why - how - when
• positive pressure check– why - how - when
![Page 18: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/18.jpg)
Other Important Issues• Medical fitness to wear a respirator
• Facial hair & respiratory protection
• Care & cleaning of respirators
• Inspection of respirators
• Cleaning & disinfection
• Repairs
• Storage
![Page 19: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/19.jpg)
Respiratory Program
– written SOP
– MSHA/NIOSH certified respirators
– appropriate for hazard
– training of wearer
– individual respirators
– cleaning & disinfection
– respirator storage
– inspection & repair
– work area monitoring
– medical review
– annual evaluation of respiratory program
• Minimum Requirements:
![Page 20: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/20.jpg)
NIOSH Recommendation:
"Respiratory protection may be necessary for certain operations or methods such mold removal and paint removal by chemicals, heat gun, or abrasive techniques, and some set-up, and cleaning operations. However, respirators are the least preferred method of controlling airborne Mold exposure, and they should not be used as the only means of preventing or minimizing exposures. Respiratory protection requirements are not an acceptable substitute for adequate training, supervision, appropriate engineering controls, and environmental or medical monitoring. Initial respiratory protection requirements for abatement work (which may be based on conservative assumptions) should be modified with appropriate job-specific requirements based on air monitoring results. Respirator selection for each job category at every worksite should be determined by an industrial hygienist or other qualified individual, based on
maximum airborne exposures measured."
NIOSH
![Page 21: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/21.jpg)
Respirators
• 29 CFR 1910.134
• In any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer, the employer shall establish a written respiratory protection program with worksite-specific procedures.
![Page 22: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/22.jpg)
Asbestos What Is It?
• Asbestos minerals share some common characteristics
Naturally occurring from Ores rich in Magnesium, Calcium, Silica, and Iron
High tensile strength along the axis of the fiber
Chemically inertNon-combustible
![Page 23: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/23.jpg)
ACM Categories
Surfacing Materials Sprayed/trowled-on
materials
Thermal System InsulationsInsulating material used to
prevent heat loss/gain
Miscellaneous Materials
Any ACM that is not considered to be surfacing material or thermal system
insulting
![Page 24: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/24.jpg)
Surfacing Material
![Page 25: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/25.jpg)
Ceiling Plaster
![Page 26: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/26.jpg)
Mold on Asbestos Containing Materials
ACM- Pipe insulation (T.S.I)
ACM- Spackle/Joint compound
![Page 27: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/27.jpg)
Damaged Pipe Insulation
![Page 28: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/28.jpg)
Damaged Boiler Insulation
![Page 29: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/29.jpg)
Fire-Stop Insulation
![Page 30: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/30.jpg)
Duct Insulation
![Page 31: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/31.jpg)
Definition
• ACM= Asbestos Containing Materials• This is any material that contains greater than 1% asbestos
fibers• PACM=Presumed Asbestos Containing Materials• This is any TSI, Surfacing, or Misc vinyl/asphalt flooring or
roofing installed before 1980It should be noted that New York State Department of Labor (NYSDOL), United States Environmental Protection Agency (EPA), and the Occupational Safety and Health Administration (OSHA) all have specific requirements for the testing, handling and disposal of ACM, also for licensing and training. One should always check with all applicable regulations before disturbing any Known or suspect ACM/PACM present on a mold remediation/Assessment
![Page 32: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/32.jpg)
Lead Based Paint
On Mold remediation projects Lead based paint can also be impacted. •It will typically be in the paint on or near the areas with mold growth
•Demolition or removal of these painted surfaces can create potentially dangerous exposures to Lead dust and lead contaminated debris
![Page 33: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/33.jpg)
Why are Dust and Debris a Problem?
• Remediation activities that disturb lead-containing materials create dust and debris
• Lead-contaminated dust is poisonous• Very small amounts of lead-contaminated dust can
poison children and adults– Children swallow dust during ordinary play activities. – Adults swallow or breathe dust during work activities.
• Workers can bring lead-contaminated dust home and poison their families
![Page 34: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/34.jpg)
• Definition of a confined space is any space that– A person can enter– Has a limited opening for entry or exit– Is not designed for continuous occupancy
• A confined space that has any associated hazard is considered a permit-required confined space
• Hazards can include oxygen deficient or enriched atmospheres, toxic or flammable atmospheres, mechanical or electrical hazards, falls, engulfment, etc.
www.environmentaleducation.com
![Page 35: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/35.jpg)
•Do not enter a confined space to attempt to rescue unless you are properly trained and outfitted with the correct protective equipment (including your own safety retrieval harness, with someone tending your line).
• Respirators are limited in their ability to protect the wearer from atmospheric hazards. For example, a negative pressure or powered air purifying respirator will not protect you against insufficient oxygen or a host of other contaminants for which the respirator was not designed. Therefore, only self-contained breathing apparatus can be worn during confined space rescues.
![Page 36: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/36.jpg)
60% of confined space deaths are among would-be rescuers.
Don’t become a statistic!
![Page 37: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/37.jpg)
Electrical Hazards
• Electrocution and electric shocks are among the most common hazards.
• Incorrect wiring, improper grounding, and lack of proper insulation result in over 1,000 people being electrocuted each year
![Page 38: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/38.jpg)
Worker Responsibilities
• Being aware of potential hazards
• Knowing how hazards should be treated
• Knowing what to do to protect themselves from electrical shock while working in a regulated abatement work area.
![Page 39: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/39.jpg)
• Cords can be damaged by:– Aging
– Door or window edges
– Staples or fastenings
– Abrasion from adjacent materials
– Activity in the area
– Improper use can cause shocks, burns or fire
![Page 40: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/40.jpg)
• “Authorized “ person will de-energize all sources
• Locking device will be applied at energy source
• Lock must be unique in appearance and used for no other purpose
• Tag deactivated controls
• Tag de-energized equipment and circuits at all points where they can be energized
• Tags must identify equipment or circuits being worked on
• A separate tag and lockout is provided for each crewmember requiring de-energizing of same line or equipment
![Page 41: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/41.jpg)
• When to Lock Out/Tag Out?
• Any time injury could result from unexpected start-up of machinery
• Any time injury could result from release of energy– Electrical energy– Chemical energy– Hydraulic pressure– Air pressure– Steam pressure
www.environmentaleducation.com
![Page 42: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/42.jpg)
Steps for Reducing Electrical Hazards
• Inspect for wiring faults• Remove all electrically powered equipment• Protect cables lines and outlets
![Page 43: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/43.jpg)
• Protect from contact and damage, and don’t allow to lay on the ground
www.environmentaleducation.com
![Page 44: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/44.jpg)
• Plastic or rubber covering is missing
• Damaged extension cords & tools
![Page 45: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/45.jpg)
• Tools plugged into improperly grounded circuits may become energized
• Broken wire or plug on extension cord
• Some of the most frequently violated OSHA standards
![Page 46: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/46.jpg)
Hazards may result from:
• Too many devices plugged into a circuit, causing heated wires and possibly a fire
• Damaged tools overheating• Lack of overcurrent protection• Wire insulation melting, which
may cause arcing and a fire in the area where the overload exists, even inside a wall
![Page 47: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/47.jpg)
• Tripped circuit breakers or blown fuses
• Warm tools, wires, cords, connections, or junction boxes
• GFCI that shuts off a circuit
• Worn or frayed insulation around wire or connection
![Page 48: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/48.jpg)
Scaffolds
Specific OSHA standards apply to the specific use of scaffolding, which must be reviewed prior to construction or use
![Page 49: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/49.jpg)
The height of the scaffold should not be more than four times its minimum base dimension unless guys, ties, or braces are used
www.environmentaleducation.com
![Page 50: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/50.jpg)
Employees can’t be on a moving scaffold unless: Surface is level Height to base ratio is 2 to 1 Outriggers are installed on both
sides of scaffolds Employees can’t be on scaffold
while it is being moved
www.environmentaleducation.com
![Page 51: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/51.jpg)
Slips, Trips and Falls
• Mold remediation sites present some significant risks for slips, trips and falls.
• Non-slip rubber boots or shoes with non skid soles can greatly reduce slips and falls when working on wet polyethylene
• No running, jumping, or “horseplay” should be allowed in the work area
![Page 52: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/52.jpg)
• If you can fall more than 6 feet, you must be protected
• Use fall protection on:– walkways & ramps, open sides & edges,
holes, excavations, roofs, wall openings
• Protective measures include guardrails, covers, safety nets, and Personal Fall Arrest Systems
www.environmentaleducation.com
![Page 53: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/53.jpg)
Fire Emergency Procedures
• OSHA requires a written emergency action fire prevention plan The manner in which emergencies are communicated Emergency escape procedures and emergency escape
routes Procedures for any employee who must stay back to deal
with critical plant operations which may take time to safely shut down
Procedures to account for all employees after evacuation Rescue and medical duties
![Page 54: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/54.jpg)
• The body naturally tries to cool itself by sweating• If you are wearing an impermeable suit, your body heat
cannot escape• Your lungs are already in overdrive due to the added
stress of the respirator• The Air Conditioning has been shut off for the summer,
and the air in the work area is much warmer than the air outside
• Perfect conditions for the onset of HEAT STRESS or HEAT STROKE
![Page 55: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/55.jpg)
• Take frequent breaks, reduce body temperature
• Drink small amounts of cool liquids as often as possible
• Monitor heart rate after breaks – should return to within 10% of normal
• Body core temp should remain below 102 degrees
![Page 56: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/56.jpg)
• Noise from power equipment
• OSHA requirements– Action Level– Permissible Exposure Level
• Types of protective equipment
![Page 57: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/57.jpg)
Hazard Communication Right to Know
• If chemical hazards are introduced to the workplace, the employer must have a written hazard communication program to inform employees of these hazards.
• Hazardous materials may be present on mold remediation sites for a number of reasons.
• Examples of potentially hazardous materials include spray adhesives, surfactants, fungicides/biocides-, disinfectants, paints and coatings, mastic removers, solvents and cleaning agents.
![Page 58: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/58.jpg)
Hazard Communication Plan Elements
Comprehensive written program
• Labeling of hazardous materials in the workplace
• Availability of Safety Data Sheets (SDS)
• Employee training
![Page 59: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/59.jpg)
Hazard Communication Plan Elements
A written Hazard Communication Program which must include:•Plans to meet the criteria of the standard relating to the labeling, safety data sheets, and employee training.• A list of hazardous chemicals/materials.
![Page 60: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/60.jpg)
Hazard Communication Plan Elements
Labels• All containers in the work place must be labeled,
marked, or tagged with the identity of the hazardous material contained and the appropriate hazard warnings, and the name and address of a responsible party.
• An exception from labeling is given for containers used by a single individual which hold only sufficient product for use during one shift.
![Page 61: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/61.jpg)
• Roll-over protective structures• Reverse alarms• Operator will look out for workers but workers
must be aware of “blind spots”• Always make eye contact before approaching
operator• Beware of “swing range” and areas near
stabilizer pads
![Page 62: PPE, Respirators, asbestos, confined spaces, lock out/tag out.](https://reader035.fdocuments.us/reader035/viewer/2022062315/5697bfd31a28abf838cac135/html5/thumbnails/62.jpg)