Powerpoint Templates Page 1 Powerpoint Templates EVALUATION OF REFRACTIVE OUTCOMES AFTER IOL...
-
Upload
samuel-gregory -
Category
Documents
-
view
212 -
download
0
Transcript of Powerpoint Templates Page 1 Powerpoint Templates EVALUATION OF REFRACTIVE OUTCOMES AFTER IOL...
Powerpoint TemplatesPage 1
Powerpoint Templates
EVALUATION OF REFRACTIVE OUTCOMES AFTER IOL IMPLANTATION
IN POST LASIK EYES
D. RAMAMURTHY, R. CHITRA
THE EYE FOUNDATION
COIMBATORE, INDIA.
THE AUTHORS HAVE NO FINANCIAL INTEREST IN THE SUBJECT MATTER OF THIS POSTER
Powerpoint TemplatesPage 2
TO ANALYSE THE REFRACTIVEOUTCOMES AFTER CATARACT SURGERY
IN POST LASIK PATIENTS
OBJECTIVE
Powerpoint TemplatesPage 3
12 EYES OF 10 PATIENTS UNDERWENT CATARACT SURGERY 26 – 90 MONTHS POST LASIK TREATMENT
REFRACTIVE OUTCOME POST CATARACT SURGERY WAS ANALYSED SIX WEEKS AFTER CATARACT SURGERY
MATERIALS & METHODS
Powerpoint TemplatesPage 4
ALL PATIENTS HAD UNDERGONE LASIK IN OUR CENTRE
COMPLETE DATA AVAILABLE
IOL POWER CALCULATED BY
- ASCRS WEBSITE ONLINE CALCULATOR
- HAIGIS – L FORMULA IN IOL MASTER
- B – SCAN IMMERSION BIOMETRY WITH CLINICAL HISTORY
MATERIALS & METHODS
Powerpoint TemplatesPage 5
AS
CR
S W
EB
SIT
E O
NL
INE
CA
LC
UL
AT
OR
S.NO : 9 IN TABULAR COLUMN
Powerpoint TemplatesPage 6
IOL MASTER
S.NO : 9 IN TABULAR COLUMN
Powerpoint TemplatesPage 7
IMMERSION
S.NO : 9 IN TABULAR COLUMN
Powerpoint TemplatesPage 8
CLINICAL HISTORY
REFRACTION
PRE LASIK : – 9.75 DSPH / - 0.75 DCYL X 180°
POST LASIK : PLANO
CORRECTION ACHIEVED : - 10.13 (SPHERICAL EQUIVALENT)
PRE LASIK KERATOMETRY
OD K1 : 45.70 D
K2 : 45.20 D
AVG K : 45.45 D
KERATOMETRY FOR IOL POWER CALCULATION
45.45 -10.13
ACTUAL K FOR IOL POWER CALCULATION : 35.33 D
IOL POWER CALCULATED BY CLINICAL HISTORY : 19D
S.NO : 9 IN TABULAR COLUMN
Powerpoint TemplatesPage 9
S.NOCORRECTION
ACHIEVED BY LASIK
IOL POWER CALCULTEDIOL
POWER POST OP
REFRACTIONIDEAL
POWERCLOSEST
ASCRSHAIGIS -
LCLINICAL HISTORY
1 - 15.50 / -2.75 X 90 +20.83DS +22.50DS +20.0DS +22.0DS -1.0DS (6/18) +21.0DS ASCRS
2 - 11.0 / - 3.50 X 25 +23.67DS +25.0DS +22.50DS +23.50DS PLANO(6/9) SAME ASCRS
3 - 16.0 / -1.0 X 170 +15.08DS +15.0DS +16.0DS +15.0DS+0.50DS/-
2.25*130(6/18)+15.50DS ASCRS
4 -15.5 +13.91DS +12.50DS +16.50DS +14.0DS PLANO(6/18) SAME ASCRS
5 - 13.0 / - 1.75 X 160 +20.89DS +23.0DS +19.50DS +20.50DS PLANO(6/9) SAME ASCRS
6 - 6.0 / - 2.0 X 5 +21.50DS +22.0DS +21.0DS +21.50DS -1.0DS(6/9) +20.50DSCLINICAL HISTORY
7 - 7.25 / - 1.25 X 30 +22.67DS +20.50DS +23.50DS +22.50DS-0.50DS/-
0.50*40(6/6)+22.0DS ASCRS
8 - 8.50 / -1.50 X 10 +20.95DS +19.50DS +21.50DS +21.0DS PLANO(6/6P) SAME ASCRS
9 - 9.75 / - 0.75 X 180 +18.07DS +17.0DS +19.0DS +18.0DS +0.75DS(6/9P) +19.0DSCLINICAL HISTORY
10 - 7.5 / - 0.75 X 160 +19.16DS +19.0DS +19.0DS +18.50DS +0.50DS(6/9) +19.0DS AS/CH/HL
11 - 6.75 / - 1.75 X 180 +22.09DS +21.50DS +21.0DS +21.0DS PLANO(6/9) SAMECLINICAL HISTORY
12 - 5.50 / - 1.0 X 180 +21.57DS +21.50DS +20.0DS +20.50DS PLANO(6/6P) SAMECLINICAL HISTORY
POST LASIK CATARACT OUTCOMES
Powerpoint TemplatesPage 10
EMMETROPIA WAS ACHEIVED IN 6 OUT OF 12 EYES
ALL EYES HAD RESIDUAL ERROR < 1 D SPH
1 EYE HAD RESIDUAL 2.25 D CYL WHICH WAS PREEXISTENT & CANNOT BE ATTRIBUTED TO ERROR IN IOL POWER CALCULATION
ASCRS CALCULATION PREDICTED THE CLOSEST POWER IN 7 EYES
CLINICAL HISTORY PREDICTED CLOSEST IN 4 EYES
ASCRS /CLINICAL HISTORY / HAIGIS L ALL PREDICTED CORRECTLY IN 1 EYE
POST LASIK CATARACT OUTCOMES
Powerpoint TemplatesPage 11
CONCLUSION
IN OUR SERIES
ASCRS ONLINE CALCULATOR PREDICTS IOL POWER MOST ACCURATELY
FOLLOWED BY CLINICAL HISTORY AND LEAST PREDICTABLE WAS HAIGIS – L
VALUES WITH IOL MASTER