Power System, Rectifier
Transcript of Power System, Rectifier
Complete Network Power Productsfor Business-Critical Continuity™
2008~2009 Catalog
3
1
7
7
9
11
9
8
1
44
6
5
2
2
5
1
11010
8
9
6
6
6
11
3
No other organization can match the
scope of Emerson Network Power’s
product offerings and service
reach, nor provide such complete
grid-to-chip protection to ensure
Business-Critical Continuity™
for your technology
investment.
Grid-to-chip protection for your critical investments
Emerson Network Power supportsthese Centers of Expertise with thelargest global services organization in theindustry, delivering:
– Design, installation and startup
– Warranty service
– Preventive maintenance
– 24x7 remote monitoring
– Emergency service
– Site audits
Services
1
22
111
5
DC POWER 1
AC POWER 23
RACKS & INTEGRATED CABINETS 41
PRECISION COOLING 43
MONITORING 48
EMBEDDED POWER 54
ContentsA Full Spectrum of Products of Emerson
Network Power
OUTSIDE PLANT 16
Supporting voice and communications networks with
dependable DC power solutions. We’ve built on trusted
names-lorain®,Actura and PS-to create NetSure™
DCPower Solutions,the next-generation global technology
platform that delivers the most rigorous network-power
applications,with an unparalleled breadth DC power,
distribution,control and monitoring systems.
DC Power. Yet another way Emerson Network Power
enables Business-Critical Continuity™.
DC POWER
EMERSON NETWORK POWER.
THE GLOBAL LEADER IN ENABLING
BUSINESS-CRITICAL CONTINUITY.™
AC POWER
CONNECTIVITY
DC POWER
EMBEDDED COMPUTING
EMBEDDED POWER
MONITORING
OUTSIDE PLANT
POWER SWITCHING
& CONTROLS
PRECISION COOLING
RACKS & INTEGRATED
CABINETS
SERVICES
SURGE PROTECTION
1
DC Power System
Confi guration MatrixLarge system Medium System Medium System Small System
NetSure 801 PS48600-3/2900-X5 PS48250-1A/2900 PS48250-1B/2900 PS48250-1C/2900 PS48165/3200
Max. Power 348kW 34.8kW 14.5kW 14.5kW 14.5kW 9.6kW
Voltage -48V -48V -48V -48V -48V -48V
Max. Current 6000A 600A 250A 250A 250A 165A
Max. Number of Rectifi ers 60 12 5 5 5 3
Rectifi er Type R48-5800 R48-2900 R48-2900 R48-2900 R48-2900 R48-3200,R48-2900
Controller Type M810G M500F M501D M501D M501D M501D
Dimension Multi-cabinet system 600×600×2000 600×600×2000 600×400×2000 600×400×700600×600×1600
or 584×327×132
Medium System Medium System Small System Small System Medium System
PS48360/1800 PS48300/1800-X6 PS48120/1800-X6 PS4875/25 PS24600/75 PSC48150/25
Max. Power 20.88kW 17.4kW 6.96kW 4.35kW 17.4kW 7.2kW
Voltage -48V -48V -48V -48V +24V -48V
Max. Current 360A 300A 120A 75A 600A 150A
Max. Number of Rectifi ers 12 10 4 3 8 6
Rectifi er Type R48-1800 R48-1800 R48-1800 HD4825-3 HD2475-2 C24/48-1200
Controller Type M501D M501D M501D PSM-A10 PSM-A11
Dimension 600×600×2000 600×600×1600 600×600×2000 450×260×700 600×600×2000 200×400×1460
2
DC Power System
NetSure 801Stand-alone DC Power Series-48VDCup to 348kW
ApplicationsLarge and medium switching offi ce
Level-1 transmission backbone line
GSM mobile switching offi ce, mobile tandem exchange
CDMA mobile switching offi ce, mobile tandem exchange
DC Internet data center
System featuresSpace saving, 116kW(2000A@58V) capacity one cabinet
Capacity expandable up to 348kW(6000A@58V)
Three-phase rectifi ers (R48-5800) and SCU+(M810G) inside
Wide AC input range, 260V to 530Vac, up to 600Vac endurance without damage
System Effi ciency high up to 93%
Power factor high up to 0.99
Output current Walk-in available
Rectifi ers and controller hot swappable
Front access
Top or bottom cabling
Surge protection on AC, DC and signal side
Modularized design for system and function unit
TCP/IP, SNMP, web browser support
Rectifi er CE/UL approved
Compliance with EN60590 and EN300386, ROHS
Patented energy-saving mode
M810G
R48-5800
3
Business-Critical Continuity™
DC distribution cabinet
FeaturesLocal large LCD display
Dual mains auto/manual switchover
Front access, Top / bottom cabling
DC emergency lighting available
Expandable up to f ive AC cabinets
Lightning proof and electric Compliance with IEC
ROHS Compatible
Affi liated CabinetAC distribution cabinet
AC distribution cabinet
FeaturesIndependent monitoring unit for decentralized supply
Local large LCD display
Front access, Top / bottom cabling
DC emergency lighting available
Expandable up to 8 DC cabinets
Lightning proof and electric Compliance with IEC
ROHS Compatible
DC distribution cabinet
4
DC Power System
Dimensions And WeightCabinet Cabinet / module capacity W×D×H, mm Weight (kg)
Rectifier RackRack1000-6 Cabinet 1000A 600×600×2000 140(exclude rectifier)
Rack2000-6 Cabinet 2000A 600×600×2000 180(exclude rectifier)
AC Cabinet
PD380/400AFH-6/X1 400A 800×600×2000 240
PD380/630AFH-6/X1 630A 800×600×2000 240 Manual switchover
PD380/630AFA 630A 800×600×2000 250 Automatic switchover
DC CabinetPD48/1600DF-6/X1 1600A 800×600×2000 280
PD48/2500DF-6/X1 2500A 800×600×2000 290
DC High Ohmic
Distribution CabinetPD48/2000HF 2000A 800×600×2000 320
Integrated AC/DC
Distribution CabinetPD48/1200BFH 1200A 800×600×2000 320
Rectifier R48-5800 5800W 244×372×88 7.8
Controller M810G / 243.5×161×88 2
PD48/2000HF High Ohmic Power Distribution Cabinet
FeaturesUp to 120 branches high/low ohmic output
Local large LCD display
Front access
Lightning proof and electric Compliance with IEC
ROHS Compatible
PD48/1200BFHIntegrated AC/DC Distribution Cabinet
FeaturesAC.DC distribution unit in one cabinet
Space saving
Local large LCD display
Dual mains auto/manual switchover
Front access
Lightning proof and electric Compliance with IEC
ROHS Compatible
PD48/2000HF
PD48/1200BFH
�
Business-Critical Continuity™
PS48600-3/2900-X5
M500F
R48-2900
PS48600-3/2900-X5Integrative DC Power Series-48VDCup to 34.8kW
Applications2G, 3G mobile base stations
Medium exchanges, rural telecom networks and access networks
Transmission relay stations
Microwave/satellite communications stations
Dimensions And Weightmodel W×D×H, mm Weight (kg)
Cabinet PS48600-3/2900-X5 600×600×2000 140(rectifi er excluded)
Rectifi er R48-2900 85.5×287×132.5 3.5
Controller M500F
FeaturesCapacity up to 34.8kW (600A @ 58V)
Rectifi ers R48-2900(2900W)and SCU inside
Wide input voltage range (85 to 290Vac), up to 415Vac endurance without damage
Effi ciency high up to 93%
Power factor high up to 0.99
Output current Walk-in available
Patented energy-saving mode available
Intelligent monitoring and remote control
Surge protection on AC, DC and signal side
Rectifi ers and controller hot swappable
Front access
Top or bottom cabling
Rectifi er CE/UL approval
Compliance with RoHS
6
DC Power System
PS48250-1A/2900PS48250-1B/2900PS48250-1C/2900(ACTURA Flex 48330)Integrative DC Power Series-48VDCup to 14.5kW
Applications2G, 3G mobile base stations
Medium exchanges, rural telecom networks and access networks
Transmission relay stations
Microwave/satellite communications stations
PS48250-1A/2900
PS48250-1B/2900
PS48250-1C/2900Dimensions And Weightmodel W×D×H, mm Weight (kg)
Cabinet
PS48250-1A/2900 600×600×2000 135(rectifi er excluded)
PS48250-1B/2900 600×400×2000 125(rectifi er excluded)
PS48250-1C/2900 600×400×700 60 (rectifi er excluded)
Rectifi er R48-2900 85.5×287×132.5 3.5
Controller M500F
FeaturesCapacity up to 14.5kW (250A @ 58V)
Rectifi ers R48-2900(2900W)and SCU inside
Super fl exible confi guration
Wide input voltage range (85 to 290Vac), up to 415Vac endurance without damage
Effi ciency high up to 93%
Power factor high up to 0.99
Output current Walk-in available
Patented energy-saving mode available
Intelligent monitoring and remote control
Surge protection on AC, DC and signal side
Rectifi ers and controller hot swappable
Front access
Top cabling
Inner 660Ah battery shelves optional
Rectifi er CE/UL approval
Compliance with RoHS
7
Business-Critical Continuity™
PS48165/3200
(ACTURA OPTIMA 48200)Integrative DC Power Series-48VDCup to 9.6kW
Applications2G, 3G mobile base stations
Medium exchanges, rural telecom networks and access networks
Transmission relay stations
Microwave/satellite communications stations
Dimensions And Weightmodel W×D×H, mm Weight (kg) Distribution Unit Location
CabinetPS48165/3200 mode 1 600×600×1600 75(rectifi er excluded) Top
PS48165/3200 mode 2 600×400×1600 65(rectifi er excluded) rear
Subrack PS48165/3200 mode 3 584×327×132 20(rectifi er excluded)
FeaturesCapacity up to 9.6kW (165A @ 58V)
Rectifi ers R48-3200(3200W)and SCU inside
Wide input voltage range (85 to 290Vac), up to 415Vac endurance without damage
Effi ciency high up to 93%
Power factor high up to 0.99
Output current Walk-in available
Patented energy-saving mode available
Intelligent monitoring and remote control
Surge protection on AC, DC and signal side
Rectifi ers and controller hot swappable
Top cabling
Inner dual battery shelves optional
Rectifi er CE/UL approval
Compliance with RoHS
PS48165/3200 mode1
PS48165/3200 mode2
PS48165/3200 mode3
8
DC Power System
PS48360/1800
(ACTURA Flex 48420)Integrative DC Power Series-48VDCup to 20.8kW
Applications2G, 3G mobile base stations
Medium exchanges, rural telecom networks and access networks
Transmission relay stations
Microwave/satellite communications stations
PS48360/1800Dimensions And Weightmodel W×D×H, mm Weight (kg)
Cabinet
PS48360/1800-X1 600×600×2000 135(rectifier excluded)
PS48360/1800-X2 600×400×2000 125(rectifier excluded)
PS48360/1800-X3 600×600×1800 100(rectifier excluded)
FeaturesCapacity up to 20.8kW (360A @ 58V)
Rectifiers R48-1800(1740W)and SCU inside
Wide input voltage range (85 to 300Vac), up to 415Vac endurance without damage
Efficiency high up to 92%
Power factor high up to 0.99
Output current Walk-in available
Patented energy-saving mode available
Intelligent monitoring and remote control
Surge protection on AC, DC and signal side
Rectifiers and controller hot swappable
Front access
Top cabling
Inner 660Ah battery shelves optional
Rectifier CE/UL approval
Compliance with RoHS
R48-1800
M501D
�
Business-Critical Continuity™
PS48300/1800-X6Integrative DC Power Series-48VDCup to 14.7kW
Applications2G, 3G mobile base stations
Medium exchanges, rural telecom networks and access networks
Transmission relay stations
Microwave/satellite communications stations
Dimensions And Weightmodel W×D×H, mm Weight (kg)
Cabinet PS48300/1800-X6 600×600×1600 130(rectifi er excluded)
FeaturesCapacity up to 14.7kW (300A @ 58V)
Rectifi ers R48-1800(1740W)and SCU inside
Wide input voltage range (85 to 300Vac), up to 415Vac endurance without damage
Effi ciency high up to 92%
Power factor high up to 0.99
Output current Walk-in available
Patented energy-saving mode available
Intelligent monitoring and remote control
Surge protection on AC, DC and signal side
Rectifi ers and controller hot swappable
Front access
Top/Bottom cabling
Rectifi er CE/UL approval
Compliance with RoHS
PS48300/1800-X6
M501D
R48-1800
10
DC Power System
PS48120/1800-X6Integrative DC Power Series-48VDCup to 6.96kW
Applications2G, 3G mobile base stations
small exchanges, rural telecom networks and access networks
Transmission relay stations
Microwave/satellite communications stations
Railway stations
Dimensions And Weightmodel W×D×H, mm Weight (kg)
Cabinet PS48120/1800-X6 600×600×2000 110(rectifi er excluded)
FeaturesCapacity up to 6.96kW (120A @ 58V)
Rectifi ers R48-1800(1740W)and SCU inside
Wide input voltage range (85 to 300Vac), up to 415Vac endurance without damage
Effi ciency high up to 92%
Power factor high up to 0.99
Output current Walk-in available
Patented energy-saving mode available
Intelligent monitoring and remote control
Surge protection on AC, DC and signal side
Rectifi ers and controller hot swappable
Front access
Top/Bottom cabling
Inner 330Ah battery shelves optional
Rectifi er CE/UL approval
Compliance with RoHS
PS48120/1800-X6
M501D
R48-1800
11
Business-Critical Continuity™
PS4875/25Wall-mounted Integrative DC Power Series-48VDCup to 4.35kW
Applications2G, 3G mobile base stations
Small exchanges, rural telecom networks and access networks
Transmission relay stations
Microwave/satellite communications stations
Railway stations
Dimensions And Weightmodel W×D×H, mm Weight (kg)
Cabinet PS4875/25 450×260×700 40(rectifi er excluded)
FeaturesCapacity up to 4.35kW (75A @ 58V)
Rectifi ers HD4825-3(1450W)inside
Wall-mounted for space saving
Wide input voltage range (90 to 290Vac), up to 415Vac endurance without damage
Effi ciency high up to 90%
Power factor high up to 0.99
Output current Walk-in available
Patented energy-saving mode available
Intelligent monitoring and remote control
Surge protection on AC, DC and signal side
Rectifi ers and controller hot swappable
Front access
Top cabling
Rectifi er CE approval
Compliance with RoHS
PS4875/25
12
DC Power System
PS4890/800 (ACTURA 48201)Subrack DC Power Series-48VDCup to 4.8kW
Applications2G, 3G mobile base stations
small access networks
Microwave/satellite communications stations
Dimensions And Weightmodel W×D×H, mm Weight (kg)
PS4890/800 single subrack 485×345×90 8.8(rectifi er excluded)
PS4890/800 dual subracks 485×345×180 17.9(rectifi er excluded)
Features19” Subrack system
Capacity up to 2.4kW one subrack, 4.8kW dual subracks
Rectifi ers R48-800(800W)and SCU inside
Wide input voltage range (85 to 300Vac)
Effi ciency high up to 91%
Power factor high up to 0.99
Output current Walk-in available
Patented energy-saving mode available
Intelligent monitoring and remote control
BLVD, LLVD optional
Rectifi ers and controller hot swappable
Rectifi er CE/UL approval
Compliance with RoHS
13
Business-Critical Continuity™
Applications2G, 3G mobile base stations
Medium exchanges, rural telecom networks and access networks
Transmission relay stations
Microwave/satellite communications stations
PS24600/75Integrative DC Power Series+24VDCup to 17.4kW
Dimensions And Weight model W×D×H, mm Weight (kg)
Cabinet PS48600-3/2900-X5 600×600×2000 158(rectifi er excluded)
Rectifi er HD2475-2 105×400×245 8
Controller PSM-A11
Key FeaturesCapacity up to 17.4kW (600A @29V)
Rectifi ers HD2475-2(2175W)inside
Wide input voltage range (120 to 290Vac), up to 415Vac endurance without damage
Effi ciency high up to 88%
Power factor high up to 0.99
Intelligent monitoring and remote control
Surge protection on AC, DC and signal side
Rectifi ers and controller hot swappable
Front access
Top or bottom cabling
Rectifi er CE approval
Compliance with RoHS
PS24600/75
14
DC Power System
PSC48150/25Integrative DC Power Series+24Vdc/-48Vdc, 7.2kW
Applications2G, 3G mobile base stations
Medium exchanges
Transmission relay stations
Microwave/satellite communications stations
Dimensions And Weightmodel W×D×H, mm Weight (kg)
Cabinet PSC48150/25 200×400×1460 45(rectifi er excluded)
DC/DC converter C24/48-1200 85.5×287×132.5 2.5
Features+24V/-48V DC/DC system
Capacity up to 7.2kW
Wide DC input voltage range: 21V~29V
DC/DC module(1200W)inside
DC/DC converter Hot-swappable
Extremely low radiation, meeting
Relay output for alarm port
Complete lightning proof in input and output rated at 5KA(8/20us)
Complete fault protection functions
Optional remote monitor and control
Front access
Compliance with RoHS
PSC48150/25
1�
Business-Critical Continuity™
OUTSIDE PLANT
EMERSON NETWORK POWER.
THE GLOBAL LEADER IN ENABLING
BUSINESS-CRITICAL CONTINUITY.™
AC POWER
CONNECTIVITY
DC POWER
EMBEDDED COMPUTING
EMBEDDED POWER
MONITORING
OUTSIDE PLANT
POWER SWITCHING
& CONTROLS
PRECISION COOLING
RACKS & INTEGRATED
CABINETS
SERVICES
SURGE PROTECTION
Protecting and moving voice,video and data from the
central offi ce closer to the subscriber. We deliver a full line of
enclosures,cabinets and shelters that meet the networked
world’s demands for high speed without interruption,
from MESA® and DEC integrated enclosure solutions to
Emerson Network Power ES, EC, EPC outdoor power solutions
to cross-connects to ProFORM® distribution terminals to
NetSpanTM Integrated FTTx Solutions.
OUTSIDE PLANT. Yet another way Emerson Network power
enables Business-Critical Continuity™.
16
EPC48180/1800-FA-48VDC Outdoor Power Cabinet
Dimensions And Weightmodel W×D×H, mm Weight (kg)
Cabinet EPC48180/1800-FA 700×700×1700 150(rectifiers and batteries excluded)
FeaturesCapacity up to 10.44kW (180A @ 58V)
Totally front access in favor of space-saving
Forced vent cooling system
Patent design of Isolated air channel for safe operation
IP55 for equipment chamber
Forced vent cooling for battery chambers
Wide input voltage range (85 to 300Vac), up to 415Vac endurance without damage
Rectifiers R48-1800(1740W) and SCU inside
Efficiency high up to 92%
Power factor high up to 0.99
Output current Walk-in available
Perfect fan speed control for energy-saving
Patent energy-saving mode available
Intelligent monitoring and remote control
Surge protection on AC, DC and signal side
Class B+C lightning protection optional
Rectifiers and controller hot swappable
Inner dual 330Ah battery Chambers
Rectifier CE/UL approval
Compliance with EN60950 and IEC60950, RoHS
H-mast platform installation available
ApplicationsOutdoor stations of GSM, UMTS, CDMA
Fiber optic transmission systems
Digital loop carriers
EPC48180/1800-FA
17
Business-Critical Continuity™
EPC48120/1800-F-48VDC Outdoor Power Cabinet
Dimensions And Weightmodel W×D×H, mm Weight (kg)
Cabinet EPC48120/1800-F 600×630×1500 140(rectifi ers and batteries excluded)
FeaturesCapacity up to 6.96kW (120A @ 58V)
Totally front access in favor of space-saving
Forced vent cooling system
IP45 for equipment chamber
Patent design of Isolated air channel for safe operation
Forced vent cooling for battery chambers
Wide input voltage range (85 to 300Vac), up to 415Vac endurance without damage
Rectifi ers R48-1800(1740W)and SCU inside
Effi ciency high up to 92%
Power factor high up to 0.99
Output current Walk-in available
Perfect fan speed control for energy-saving
Patent energy-saving mode available
Intelligent monitoring and remote control
Surge protection on AC, DC and signal side
Class B+C lightning protection optional
Rectifi ers and controller hot swappable
Inner dual 330Ah battery Chambers
Rectifi er CE/UL approval
Compliance with EN60950 and IEC60950, RoHS
H-mast platform installation available
ApplicationsOutdoor stations of GSM, UMTS, CDMA
Fiber optic transmission systems
Digital loop carriers
EPC48120/1800-F
18
Outside Plant
EPC48120/1800-HA(B)-48VDC Outdoor Power Cabinet
Dimensions And Weightmodel Op. temp. W×D×H, mm Weight (kg)
CabinetEPC48120/1800-HA -10~+45℃
600×600×1700 150(rectifiers and batteries excluded)EPC48120/1800-HB -40~+45℃
FeaturesCapacity up to 6.96kW (120A @ 58V)
Totally front access in favor of space-saving
Heat-exchange cooling system
IP55 for equipment chamber
Wide operation temperature, -40~+45℃ optional
Patent design of Isolated air channel for safe operation
Forced vent cooling for battery chambers
Wide input voltage range (85 to 300Vac), up to 415Vac endurance without damage
Rectifiers R48-1800(1740W)and SCU inside
Efficiency high up to 92%
Power factor high up to 0.99
Output current Walk-in available
Perfect fan speed control for energy-saving
Patent energy-saving mode available
Intelligent monitoring and remote control
Surge protection on AC, DC and signal side
Class B+C lightning protection optional
Rectifiers and controller hot swappable
Inner dual 330Ah battery Chambers
Rectifier CE/UL approval
CE mark
Compliance with EN60950 and IEC60950, RoHS
H-mast platform installation available
ApplicationsOutdoor stations of GSM, UMTS, CDMA
Fiber optic transmission systems
Digital loop carriers
EPC48120/1800-HA
EPC48120/1800-HB
19
Business-Critical Continuity™
EC200T/01Outdoor Battery Cabinet
Dimensions And Weightmodel Op. temp. W×D×H, mm Weight (kg)
Cabinet EC150F/01 -10~+55℃ 650×720×1400 100(batteries excluded)
FeaturesCater up to 3 strings of 165Ah batteries
Thermoelectricity cooler (TEC) inside
Inner temperature 5~15℃ below outside ambient
IP55
Dry-contact alarm for fans and door sensor
Compliance with RoHS
ApplicationsOutdoor stations of GSM, UMTS, CDMA
Fiber optic transmission systems
Digital loop carriers
EC200T/01
20
Outside Plant
EC150F/01
EC150F/01Outdoor Battery Cabinet
Dimensions And Weightmodel Op. temp. W×D×H, mm Weight (kg)
Cabinet EC150F/01 -10~+45℃ 700×700×1000 100(batteries excluded)
FeaturesCater up to 2 strings of 165Ah batteries
Forced vent cooling
IP34
Dry-contact alarm for fans and door sensor
Compliance with RoHS
ApplicationsOutdoor stations of GSM, UMTS, CDMA
Fiber optic transmission systems
Digital loop carriers
21
Business-Critical Continuity™
EC100F/01Outdoor Battery Cabinet
Dimensions And Weightmodel Op. temp. W×D×H, mm Weight (kg)
Cabinet EC100F/01 -10~+45℃ 600×600×1000 100(batteries excluded)
FeaturesCater up to 2 strings of 165Ah batteries
Forced vent cooling
IP34
Dry-contact alarm for fans and door sensor
Compliance with RoHS
ApplicationsOutdoor stations of GSM, UMTS, CDMA
Fiber optic transmission systems
Digital loop carriers
EC100F/01
22
Outside Plant
Sustaining critical operations that simply can’t
go down. We deliver a full range of uninterruptible
Liebert® AC power systems and complete
associated power distribution and enclosures,
from individual products to integrated systems
that keep network closets up and running.
AC Power. Yet another way Emerson Network
Power enables Business-Critical Continuity™.
AC POWER
EMERSON NETWORK POWER.
THE GLOBAL LEADER IN ENABLING
BUSINESS-CRITICAL CONTINUITY.™
AC POWER
CONNECTIVITY
DC POWER
EMBEDDED COMPUTING
EMBEDDED POWER
MONITORING
OUTSIDE PLANT
POWER SWITCHING
& CONTROLS
PRECISION COOLING
RACKS & INTEGRATED
CABINETS
SERVICES
SURGE PROTECTION
23
24
AC Power
AC POWER
Confi guration MatrixSmall System Medium System Small System
SERIES: US11R iTrust 31 iTrust 2G
RATING: 1/2/3KVA 10/15/20KVA 3/6/9/12/15/18KVA
MOUNTING: Tower/Rack Tower Tower/Rack
I/O: 1-ph./1-ph. 3-ph./1-ph. 1-ph./1-ph.
VOLTAGE: 220/230/240 (L-N) 380/220 220 (L-N)
FREQUENCY: 50Hz 50Hz 50Hz
Large system Medium System
SERIES: NX Hipulse-U Outdoor UPS
RATING: 10/15/20/30/40/60/80/100/120/140/160/200KVA 160/200/300/400KVA 2KVA/3KVA
MOUNTING: Tower Tower Tower
I/O: 3-ph./3-Ph. 3-ph./3-ph. 1-ph./1-ph.
VOLTAGE: 380/400/415 (L-L) 380/400/415 (L-L) 220(L-N)
FREQUENCY: 50/60Hz 50/60Hz 50Hz
US11-R Series——1/2/3KVA
Special FeaturesRack/Tower design, adaptable for table and 19' IT rack application
Double conversion, true on-line style
Fully digital control
Input surge suppressor equipped
CE marked
IGBT based rectifier and excellent input performance
Super wide input window
Mutiple AC output connections
2U height
High EMC performance, classB achieved
Intelligent battery management
Dimensions And WeightModel Name Size(WDH in MM) Weight(Kg)
US11R-0010 440×400×87 17.5
US11R-0010L 440×400×87 7.8
US11R-0020 440×400×87 29.1
US11R-0020L 440×400×87 9.6
US11R-0030 440×400×87 30.5
US11R-0030L 440×400×87 10.5
UF-B0007-06 440×400×87 20.5
UF-B0009-06 440×400×87 21.5
Note: US11R-0020 will be shipped with a VF-B0007-06 US11R-0023 will be shipped with a VF-B0009-06
25
Business-Critical Continuity™
ApplicationsServers/Storage/Workstation
Telecommunication, VoIP
Small Office Network
Data Warehouses
Medical Diagnostics
Process Automation Equipmentsv
US11-R Series Datasheet
ModelUS11R-0010 US11R-0020 US11R-0030
US11R-0010L US11R-0020L US11R-0030L
Nominal Power Rating at 0.7 PF 1KVA 2KVA 3KVA
Input Parameters
Rectifi er Type IGBT-based PFC(Power Factor Correction)
Input Voltage 220Vac, 1-ph, 3-w
Permissible Input Voltage Range 120-288Vac
Permissible Input Frequency Range 50Hz ±2%,5%,7%,10% User selectable
Input Power Factor at nominal voltage ≥0.99
Battery
Battery Type Maintenace Free, VRLA (Valve Regulated Lead Acid)
Nominal Battery Bus 36Vdc 72Vdc 72Vdc
Recharging Time to 90% Recovery <4 hours <4 hours <4 hours
Output Parameters
Inverter Type IGBT-based Inverter
Output Power 0.7kW 1.4kW 2.1kW
Output Connection GB/IEC GB/IEC GB/IEC/Terminal
Output Voltage 220Vac, 1-ph, 3-w
Output Frequency 50Hz ±0.2%
Output Voltage THD <3% at linear load; < 5% at non-linear load
Capability to handle High Crest Factor Load 3:1 (compliant with IEC 62040-3)
Capability to handle Step Load 100%
Overload Capability
105% FL Infi nite
105-125% FL for 5 mins
125-150% FL for 1min
>150% FL for 10s
System Parameters & Standards
AC-AC Effi ciency >89% >90% >90%
Switch Time When Input Fails 0s
Noise <43dB <45dB
Display LED
Dimension (W×D×H)mm 440×400×87
U-Height 2u 2u 2u
Weight (Standard/L model) 17.5/7.8kg 29.1/9.6 30.5/10kg
Safety EN62040-1-1, CE Marked
EMI /EMC EN50091-2 Class B
Inmunity EN50082-1
Surge Protection IEC 60664-1 Level IV
Protection IP21
Communication & Management
Interface Port Serial / Dry Contact / SNMP Card
Web/SNMP Card Optional
Environmental Parameters
Operating Temperature Range 0℃ to 40℃ (UPS) & 25℃ ±5 (Battery)
Relative Humidity 0% to 95% (non-condensing)
Maximum Altitude above MSL 1500m (as per IEC 62040-3)
26
AC Power
UH31 Series—10/15/20KVA
ApplicationsSmall data centers of banks/stock exchanges, server groups, small/middle computer rooms,
offices, PC groups, important facilities, etc
FeaturesThree phases input, one phase output ( 220/230Vac)
True on-line style
IGBT based rectifier/inverter
DSP control
Super wide input window (-45%~+15%)
On-line operation when input phases lose
D-class surge suppressor equipped
Intelligent battery management
Chinese/English LCD interface available
Class A EMC standard acquired
Input phase loss tolerance
Dimensions And WeightModel Name Size(WDH in MM) Weight(Kg)
UH31-0100L 280×875×770 97
UH31-0150L 280×875×770 97
UH31-0200L 280×875×770 116
27
Business-Critical Continuity™
Model UH31-0100L UH31L-0150 UH31-0200L
Nominal Power Rating at 0.7 PF 10KVA 15KVA 20KVA
Input Parameters
Rectifi er Type IGBT-based PFC (PF Corrected)
Input Voltage 380Vac, 3-ph, 4-w
Permissible Input Voltage Range 120Vac-276Vac
Permissible Input Frequency Range 45-55Hz
Input Power Factor at nominal voltage ≥0.95
Battery
Battery Type VRLA (Value Regulated Lead Acid)
Nominal Battery Bus 480Vdc 480Vdc 480Vdc
Output Parameters
Inverter Type IGBT-based Inverter
Output Power 7kW 10.5kW 14kW
Bypass Voltage Range 120Vac-253Vac
Output Voltage 220Vac, 1-ph, 3-w
Output Voltage Regulation ±0.5%
Output Frequency 50Hz
Output Voltage THD < 3% at linear load; < 5% at non-linear load
Capability to handle High Crest 3:1 (compliant with IEC 62040-3)
Factor Load
Capability to handle Step Load 100%
Overload Capability
105-125% FL for 10 mins
125-150% FL for 1min
>150% FL for 200ms
System Parameters &Standards
AC-AC Effi ciency >91% >92%
Switch Time When Input Fails 0s
Noise <55dB <60dB
Display LED+LCD
Dimension (W×D×H) 280×875×770mm
Weight (Standard/L model) 97kg 116kg
Safety EN60950
Immunity EN61000-4-2,3,4,6,8,11 Level III, EN61000-4-5 Level IV
EMC EN55022 Class A
Surge Protection IEC 60664-1 Level IV
Parameters &Standards
Operating Temperature Range 0℃ to 40℃ (UPS) & 25℃ ±5℃ (Battery)
Relative Humidity 0% to 95% (non-condensing)
Maximum Altitude above MSL 1500m (as per IEC 62040-3)
UH31 Series Datasheet
28
AC Power
iTrust 2G Series UPS
ApplicationsIndustrial equipments
Small data centers
Computing centers
Telecommunication network hubs
FeaturesModular Design- Plug & Play
N+X Redundancy - Higher reliability
Easy and cheap expansion- Modules only
Online during maintenance- By simply replacing modules
Space saving - Compact Design
Large Capacity Battery Affordable -Extendable 10A/20A charger available
Energy Saving - High Efficiency and excellent input PF
Higher adaptability to harsh input - Extremely Wide Input window
Longer battery life available - Intelligent Battery Management
Quiet - Low noise
Less worry - Self diagnosis and Fault Prediction
Dimensions And WeightModel Name Size(WDH in MM) Weight(Kg)
Power Module UF-P0030 436 × 412 × 85 10.4
Battery Module UF-B0007-8 436 × 400 × 36 26
10A Charger Module UFP-BCH110/10 436 × 412 × 85 7.6
20A Charger Module UFP-BCH110/20 436 × 412 × 85 10.4
6-Bay Rack UP11-0180/6 500 × 552 × 994 70
12-Bay Rack UP11-0180/12 500 × 552 × 1492 105
29
Business-Critical Continuity™
Models 3KVA 6KVA 9KVA 12KVA 15KVA 18KVA
2.4kW 4.8kW 7.2kW 9.6kW 12kW 14.4kW
Model Name UP11-0180/12(12-Bay) UP11-0180/6(6-Bay)
Input Parameters
Rectifi er Type IGBT-based PFC
Input Voltage 220Vac/1ph/3w
Permissible Input Voltage Range 120-288Vac
Permissible Input Frequency Range 45-55Hz
Input Power Factor at nominal voltage ≥0.99 without any Filter
Ace
Battery
Battery Type VRLA
Nominal Battery Bus 96Vdc
Output Parameters
Inverter Type IGBT-based
Output Rating 3/6/9/12/15/18 KVA
Output Power Factor 0.8
Output Voltage 220Vac/1ph/3w
Output Voltage Regulation 1%
Output Frequency 50Hz
Capability to handle High Crest Factor Load 3:1
Capability to handle Step Load 100%
Compliance to EMC Class-A Applicable for both Radiated & Conducted
Overload Capability
105% FL for continuous running
125% FL for 10 minutes
150% FL for 10 S
System Performance
AC-AC Effi ciency > 90%
Transfer Time When Input Fail 0s
Environmental Parameters
Operating Temperature Range 0℃to 40℃ (UPS)
Relative Humidity 0% to 95% (non-condensing)
Maximum Altitude above MSL 1500m (as per IEC 62040 3)
Physical Parameters &Standards
Colour Black
Degree of Protection IP21
iTrust 2G Series Datasheet
30
AC Power
NX Series UPS
FeaturesFull digital control based on latest DSP
Advanced Vector Control to Achieve Excellent Output Performance
'Green UPS' Design with High input power factor : 0.99 Low input current harmonic of less than : 3%
Wide input window : 208-477V (L-L voltage)
Parallel up to 6 units, No MSS needed
High Efficiency: up to 94%
Compact Footorint and Front Access
Unique Dual Bus design
Flexible Power Walk-in
Built-in Redundancies to Achieve High Reliability(fans/auxiliary power supply card/..)
Intelligent battery management
Self diagnosis
Dimensions And WeightModel Name Size(WDH in MM) Weight(Kg)
NXe-10KVA 600×700×1400 180
NXe-15KVA 600×700×1400 204
NXe-20KVA 600×700×1400 204
NXe-30KVA 600×700×1400 260
NXa-40KVA 600×825×1600 340
NXa-60KVA 600×825×1600 400
NXa-80KVA 600×825×1600 445
NXa-100KVA 700×825×1800 720
NXa-120KVA 700×825×1800 720
NXa-140KVA 1000×825×1800 824
NXa-160KVA 1000×825×1800 973
NXa-200KVA 1000×825×1800 973
ApplicationsServer Rooms and Mid-sized Data Centers
Telecommunication (Fixed, WiLL & Mobile) Billing Computers
Networks (LAN, MAN & WAN), InfoCom and WiFi Hot Spots
Industrial Process & Motion Automations for Mid-sized Plants
Medical Diagnostic / Imaging Equipment
31
Business-Critical Continuity™
NX Series DatasheetModels Nxe 10 Nxe 15 Nxe 20 Nxa 30 Nxa 40 Nxa 60 Nxa 80 Nxa 100 Nxa 120 Nxa 140 Nxa 160 Nxa 200
Nominal Power Rating at 0.8 PF 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA 80KVA 100KVA 120KVA 140KVA 160KVA 200KVA
Input Parameters
Rectifi er Type IGBT-based Vector Controlled PFC (PF Corrected)
Input Voltage 380/400/415Vac (Accepted from 305-477Vac without Batt. Use)
Input Frequency 40-70Hz
Input Current THD <3% (without any Filter)
Input Power Factor ≥0.99 (without any Filter)
Flexi Power Walk-In 5 to 30S (Selectable)
Battery
Battery Type VRLA (Value Regulated Lead Acid) / Wet-Flooded / NiCd
End-Cell Voltage Selectable from 1.60-1.90Vdc/Cell (VRLA)
DC ripple Current in fl oat
mode<5%(C10 AH Capacity) RMS Value
DC ripple Voltage in
fl oat & Const V Ch.mode<1% (RMS Value)
Temperature
Compensated Battery
Charging
Standard (for in-build batteries for 10/15/20/30/40 KVA)
Optional (for all other battery confi gurations)
In-Built VRLA Battery
AvailabilityOptionally applicable for 10/15/20/30/40 KVA
Output Parameters
Inverter Type IGBT-based Vector, Repetitive & PI Controlled
Output Power 8kW 12kW 16kW 24kW 32kW 48kW 64kW 80kW 96kW 112kW 128kW 160kW
Output Voltage 380/400/415Vac * (Nominal: 400V) 3-ph, 4-w (Ph+N)
Output Voltage
Regulation±0.5%
Output Frequency 50/60±0.05Hz Regulation
Output Voltage THD 1% (max)
Max. Crest Factor Load 3:1 (compliant with IEC 62040-3)
Capability to handle
Step Load100%
Max. Leading PF Load Up to 0.9
Voltage Displacement 120o±1oel (with 100% unbalanced load)
Overload Capability 110 for 60 minutes, 125 for 10 minutes, 150 for 1 minutes
Standards
EMC Class Class A (Applicable for both Radiated & Conducted)
Enclosure IP IP 20 even with front door in opened condition, IP21 Optional
Standards &
Conformities
IEC 62040-3, IEC 62040-2, IEC 62040-1-1, IEC 60146-1-1, IEC 61000-4-2,4,5,6,8,11, EN 50091-1-1,
EN 50091-2, EN 50091-3, EN60950, EN 60529, ANSI C62.41 (IEEE 587)
Environmental Parameters
Operating Temperature
Range0 to 40℃ (UPS) & 25 ±5℃ (Battery)
Relative Humidity 0 to 95% (non-condensing)
Maximum Altitude
above MSL1000m (as per IEC 62040-3)
32
AC Power
Hipulse-U Series—160/200/300/400KVA
FeaturesFully Digital, Twin DSP controlled.
Rated at 0.9 output power factor to deliner more real power
Handle Leading Power factor Loads withour KW de-rating under specified conditions
On-Line Double Conversion
IGBT-based PWM Inverter
Wide input voltage tolerance(+15/15%)
Wide input frequency tolerance(45Hz-65Hz)
High overload capability of static bypass(14 times for 10 milliseconds and 10 times for 100
nukkusecibds)
Built-in maintenance bypass(Single and 1+N Models)
Wrap-around maintenance bypass(optional)
Front acces for spares replacement and preventive maintenance
Easy Dual bus Configuration architecture
Adjustable frequency synchronisation window up to 9% in the static bypass
Provision of automatic battery circuit breaker instead of using conventional isolator in the DC path
Field protocols ModBus/Jbus
Eady Scalability (Parallel 1+N configuration up to 6 modules paralleling)without centralised Main
Static Switch (MSS)
Bypass Switch
Compact footorint
ApplicationsMedinm & large Data Center
Telecommunication
Industrial Automation
Transport Automation
Banking, Insurance and Financial Sernices
Software Development Houses/Software Technology Parks(STP)
Building Automation
Medical Diagnostics
Satellite
Dimensions And WeightModel Name Size(WDH in MM) Weight(Kg)
Hipusle U-160KVA, 6 Pulse 1250×840×1910 1200
Hipusle U-160KVA, 12 Pulse 1640×840×1910 1725
Hipusle U-200KVA, 6 Pulse 1250×840×1910 1350
Hipusle U-200KVA, 12 Pulse 1640×840×1910 2000
Hipusle U-300KVA, 6 Pulse 1640×840×1910 1600
Hipusle U-300KVA, 12 Pulse 2280×840×1910 2200
Hipusle U-400KVA, 6 Pulse 2280×840×1910 2100
Hipusle U-400KVA, 12 Pulse 2280×840×1910 2750
33
Business-Critical Continuity™
Hipulse-U Series DatasheetHipulse UPS System
Nominal Rating(KVA)(0.9pf)/kW 160/144 200/180 300/270 400/360
Rectifi er Type 6P 12P 6P 12P 6P 12P 6P 12P
Input
Voltage 380/400/415V(+/-15%)-3Ph-4w(rectifi er:290-498V)
Frequency 50 or 60Hz +/-5%
ITHD 4 to 9% with optional harmonic fi lter
Power Factor 0.90-0.95 with optional harmonic fi lter
Output
Voltage 380/400/415V-3Ph-4w
Voltage stability
-Steady state +/-0.5%
-100% Load Step +/3%
Frequency 50 or 60Hz
Frequency Stability
-Synchronised with the bypass supply +/0.5 Hz, +/-1 Hz, +/-2Hz, +/-3Hz(settable)
-Auto-Synchronised +/0.1%
Overload copacity from inverter at vominal voltage
-3 Ph 110% for 60 minutes, 125% for 10 minutes, 150% for 1 minute
-1 Ph 200% for 30 seconds
short circuit current from inverter
-3 Ph 1.5 in for 5 seconds (in acordance with EN 50091-1-1)
-1 Ph 2.9 in for 5 seconds 2.2 in for 5 seconds
Voltage Distortion with Linear Load <3%
Voltage Distortion with 100%
Non-Linear Load<5%
Max.Deliverable Power
with Non-Linear Load(CF-3:1)100%
Max Unbalanced Load 100%
Voltage Displacement With
100% Unbalanced Load120o+/-1oel
Output Voltage Dissymmetry
with 100% Unbalanced Load2%
Standards and Approvals
Safety / EMC / Design IEC60950-1,IEC62040-1-1,UL1778,IEC62040-2 CLASS A,EN50091-CLASS A,IEC62040-3
European Directives
73/23/EEC and 89/336/EEC CE
34
AC Power
Outdoor Series
Special FeaturesNatural cooling, high system reliability achieved
Dual conversion, online style
Fully digital control
Auto start up when mains recovered
Super wide input window (150-310V L-N)
IP55 protection level
Wide operation Temperature: -40-550C
High level surge suppressor can be equipped inside; (Optional)
Boosted/float charging auto transfer
3 mounting options available (wall/mask/floor)
Zero output interrupt when input fails
Optional charger for quick battery recovery in long backup system
Heater optional for cold area
Optional Battery cabinet available with maximum 4 hours backup time at full load
Power module separate with battery enclosure, high system flexibility achieved
Dimensions And WeightModel Name Size(WDH in MM) Weight(Kg)
Outdoor 2KVA UPS UH11-0020LC 485×263×615 53*
Outdoor 3KVA UPS UH11-0030LC 485×263×615 59**
Battery Cabinet (South Type) U6-100C3S 850×550×1170 70
Battery Cabinet (North Type) U6-100C3N 850×550×1170 72
*: Including Mounting Kit,36Kg Net
**: Including Mounting Kit,42Kg Net
ApplicationOutdoor BTS
35
Business-Critical Continuity™
Outdoor Series DatasheetCapacity 2KVA/3KVA
Model Name UH11-0020LC, UH11-0030LC
Input
Rated Voltage 220Vac
Voltage Range 150-310Vac
Frequency 45~65Hz
Power Factor > 0.98
Output
Powe Factor 0.7 temp<5℃ 0.6 temp>10℃Normal Voltage 220Vac 3%
Frequency 50Hz
Frequency Tracking Rate ≤1 Hz/s
Inverter Overload Capability 105%-125%, 5mins, >125%, 20s,
Peak Factor 3:1
Bypass Voltage 150~310Vac
Effi ciency (NormalMode) >89%
Sheft Time
Utility Failure 0ms
Shift between invertermode and < 10ms
bypass mode (Synchronized )
Insulation
Insulation Resistance >2MΩ(500Vdc)
Dielectric Strength (Output to earth Input to earth)2820Vdc,leakage current <3.5mA for 1min without arc or
breakdown
Environment
Operation temperature -40℃ -55℃Storage temperature -40℃ -70℃relative humidity 10%-100% (no condensing)
altitude Under 4000m, over 4000m, de-rated,
Protection Level IP55
Noise <40dB
36
AC Power
Monitoring Solutions
FeaturesJava programming language. Web-based general-purpose monitoring software
Compatible with multi operation systems, eg., Windows, Linux, Solaris, AIX, HP-UX, etc.
Can log on via any computer on network
UPS by-layer management mode
Complete history records for inquiry, statistics and preview before printing
Multi alarming: Sound, paging, email and messages, etc.
Multi language versions, on-line upload and upgrade
WEB-configured interfaces, very easy to operate
Large storage of history records
Least system resource occupied
Strict safety management mechanism
On-line smooth access system for new equipment
Multi system environment measures accessible
Our Monitoring Solution Includes 5 Parts
1.Point-to-point and internet-based network remote monitoring, unlimited with the number of
nodes
2.SNMP Card: An internet node, providing UPS with Ethernet communication capability
3.UPS Network Adapter: Monitoring UPS products of other brands
4.UPS Adapter for Equipment Room Signals Applied together with our SNMP Card, realizing
centralized monitoring and processing of multi environment measures such as temperature,
humidity, infrared, door alarm, water immersion ( 8 analogues and 8 dry contacts)
5.Wireless MODEM: Able to send wireless messages, reporting UPS operation status and alarms to
the customers and realizing No-Man-On-Duty
37
Business-Critical Continuity™
SiteMonitor
Click on UPS icons to check all operation
indices and historical records online, with
power status completely in hand
Can name based on requirements and
display by layer
2. Clear display of UPS operation status
1. Easy installation
3. Easy setting and adjustment
U n d e r a u t h o r i z a t i o n , a n e t w o r k
administrator can remotely control the
center, eg. operate turnoff, battery self-
diagonosis, erase after sound alarm, etc.
Model selection and confi guration
38
AC Power
SNMP Card-A Bridge Connecting
UPS and NetworkThe SNMP card is based on TCP/IP communication protocol and can also
support SNMP, HTTP(web server), Telnet communication protocols to meet the
needs of all sorts of networks
FeaturesSupports web browse and NMS management systems
Software can be updated on line
10/100M network self-adapting
Hot plug-in/plug-out supported
All the settings can be done through software
39
Business-Critical Continuity™
Auto-adaptable on EOD(End Of Discharge) Adjustment
Different discharging solution for short backup-time system (<1h) and long backup-time
system(>1h)
The data of different models of batteries are stored in DSP and the UPS will detect the discharging
current and automatically adjust the EOD for best performance of the battery. In this way, over-
discharge of battery is avoided
Self-diagnosis
Battery self-diagnosis can be set to operate periodically via front panel
Auto-switch between Boost and Float Recharging
Shorten recharging period and prolong the battery life by 50%
Temperature Compensation
Auto-adjustment for fl oat charging voltage according to ambient temperature
Intelligent Battery Management
40
AC Power
Optimizing technology and performance needs
for the global IT and telecom markets. We deliver
standard and customized integrated cabinet
solutions that meet unique and specifi c needs,
from knürr and Liebert® rack solutions for
customer rooms of all sizes to knürr,MESA® and
Netspan™、Matrix™ enclosures and shelters for
wireline and wireless applications.
RACKS & INTEGRATED CABINETS .Yet another
way Emerson Network power enables Business-
Critical Continuity™.
RACKS & INTEGRATED CABINETS
EMERSON NETWORK POWER.
THE GLOBAL LEADER IN ENABLING
BUSINESS-CRITICAL CONTINUITY.™
AC POWER
CONNECTIVITY
DC POWER
EMBEDDED COMPUTING
EMBEDDED POWER
MONITORING
OUTSIDE PLANT
POWER SWITCHING
& CONTROLS
PRECISION COOLING
RACKS & INTEGRATED
CABINETS
SERVICES
SURGE PROTECTION
41
Server Enclosure Systems Rack system and IT total solution
Emerson Network Power Co.,Ltd. Launched the high reliability and high availability rack system and IT room total solution that suit the features of blade server based on its deep understanding in the user’s requirements for IT application and the existing issues.
ApplicationsNetwork access rooms
Computer rooms
Data center
Features and BenefitsWorld-leading heat dissipation design: The 83% perforating rate that is the highest in the world
meets the heat dissipation requirement of high thermal-density of blade server
Special modular structure: Modular structure and modular installation: Convenient storage and
transportation, fast and convenient disassembly and assembly
Reliable and stable power supply and distribution design: double conversion online UPS, the total
power distribution solution meets the different customer requirements
Convenient cable management: Comprehensive cable management accessories meet the
different cable management requirements
Advanced rack monitoring and safety system: Remote monitoring to the rack environment,
including temperature, humidity, door alarm and smoke, etc
Miracel Series:Product Type Capacity Width(mm) Distance(mm) High(mm)
NR-M060820 42U 600 800 2000
SR-M061020 42U 600 1000 2000
SR-M061220 42U 600 1200 2000
SR-M081020 42U 800 1000 2000
SR-M081220 42U 800 1200 2000
Accessories Fan, plinth, cable management unit, power distribution unit, etc.
42
Racks & Integrated Cabinets
Maintaining precise temperature for reliable equipment
performance. We deliver “chip-to-room cooling”-the
most comprehensive range of liebert® precision-cooling
solutions,which protect mission-critical applications
from even the slightest increase in temperature.
PRECISION COOLING. Yet another way Emerson
Network power enables Business-Critical Continuity™.
PRECISION COOLING
EMERSON NETWORK POWER.
THE GLOBAL LEADER IN ENABLING
BUSINESS-CRITICAL CONTINUITY.™
AC POWER
CONNECTIVITY
DC POWER
EMBEDDED COMPUTING
EMBEDDED POWER
MONITORING
OUTSIDE PLANT
POWER SWITCHING
& CONTROLS
PRECISION COOLING
RACKS & INTEGRATED
CABINETS
SERVICES
SURGE PROTECTION
43
Liebert DataMate3000(S) Precision cooling for Small Equipment Rooms
DataMate3000 series air conditioning is developed by Emerson Network Power
Co., Ltd. for small equipment rooms. The system provides 5.5kW , 7.5kW and
12.5kW cooling capacities and many confi guration options.
Dimensions And Weightmodel W×D×H, mm Weight (kg) Capacity
DataMate3000(s)
Indoor model
DME05W 510×386×1740 80 5.5 kW
DME07W 510×386×1740 85 7.5 kW
DME07M 500×550×1900 150 7.5 kW
DME12M 500×550×1900 160 12.5 kW
Outdoor modelDMC07W 702×408×626 34 7.5kW
DMC12W 702×408×1238 58 12.5 kW
Features and BenefitsHigh sensible cooling capacity and energy efficient. Saves 20-30% energy as compared to
"comfort" air conditioner
Provides constant temperature and humidity, high air fl ow rate and low energy consumption to
meet specifi c reqirements of computer rooms
Copeland scroll compressor provides high reliability, effi ciency and maximum life
Large LCD display, password protection and self diagnosis
Wide input voltage range, allowing voltage fl uctuation 20%
Phase loss protection ,phase order detection, automatic regulation to phase disorder
Automatic startup when utility is recovered
Front access ,easy for maintenance and fl exible installation
Standard port for monitoring equipment
Flexible and automatic switchover and alternative operation between master and slave
ApplicationsMobile base stations and control centers
Communications base stations
Outdoor equipment rooms
Microwave/Satellite earth stations
Medium ,Small computer rooms
44
Precision Air Conditioning
Liebert PEX Precision cooling for medium/large equipment room
The Liebert PEX is the next generation precision air conditioning system from
Emerson Network Power. The PEX is the latest in a long line of advanced
products from the Liebert family designed to support business-critical
applications.
Features and BenefitsFront access for convenient maintenance. There is no need to keep back or sides clear
The Liebert iCOM™ control system offers the highest capabilities of unit control, communication
and monitoring
ICOM network provides a choice of Teamwork, Lead/Lag and Cascade functions
A-Frame Evaporator Coils has larger surface to provide even air flow distribution. Its heat exchange
is highly efficient
Unique fan driving system ensures stable system operation and more efficient airflow
Infrared Humidifier, Full capacity achieved in 5-6 seconds using almost any water quality;
Approved for direct connection to potable water supplies; Autoflush™ cycle helps remove mineral
deposits
All compressorised models are designed to operate on either HCFC R22 or HFC R407C refrigerants
High kW to footprint ratio
ApplicationsData Centres
Telecom/CATV
Computer Rooms
Labs and Test Rooms
Network Centres
Production Facilities
Hospitals and medical diagnostic rooms
45
Business-Critical Continuity™
Dimensions And Weight
modelTotal Capacity(kW)
(24℃/50%RH)Weight (kg) L×W×H, mm
P1020 20.0 365
853×874×1970P1025 23.1 375
P1030 30.1 385
P1035 33.1 388
P2045 45.0 530
1704×874×1970
P2055 53.2 570
P2040 41.0 622
P2050 46.4 661
P2060 60.6 680
P2070 66.9 687
P3080 81.4 825
2553×874×1970P3090 89.3 825
P3100 100.0 835
46
Precision Air Conditioning
Liebert XDFlexible, Energy-Saving Cooling Solutions For High Heat Density Applications
ApplicationsIDC
Blade servers
High density servers and communications switches
Rooms existing high heat density
Dimensions And Weight
modelTotal Capacity(kW)
(24℃/50%RH)Weight (kg) W×D×H, mm
Main UnitXDP160 140 372 965×864×1981
XDC160 130 817 1879×879×1981
Cooling Module
XDO20 17.7 68 1829×610×572
XDV10 8.3 35 597×(749-1003)×355
XDH20 19 112 300×1066×1982
XDH32 27 112 300×1066×1982
Features and BenefitsCan cool more than 30 kW per rack
Floor-mount, rack-mount and ceiling-mount modules, plus a choice of cooling capacities, cover
any application requirements
Pumped refrigerant solutions are ideal for use around electronic equipment. No water into the
room
Scalable – add or move fan coils as your needs
Energy effi cient. Total energy savings potential of up to 40% can be achieved with the Liebert XD
solution
Minimal fl oor space requirements allow more room for IT equipment
47
Business-Critical Continuity™
Managing critical equipment activity at multiple
sites and site monitoring around the clock. We
make it easy in today’s ROL-driven business
environment,with 24/7 remote and self-
monitoring systems and services that provide
continuous oversight of data centers,computer
rooms and network closets,as well as wireless,
wireline and enterprise telecom applications.
MONITORING. Yet another way Emerson Network
power enables Business-Critical Continuity™.
MONITORING
EMERSON NETWORK POWER.
THE GLOBAL LEADER IN ENABLING
BUSINESS-CRITICAL CONTINUITY.™
AC POWER
CONNECTIVITY
DC POWER
EMBEDDED COMPUTING
EMBEDDED POWER
MONITORING
OUTSIDE PLANT
POWER SWITCHING
& CONTROLS
PRECISION COOLING
RACKS & INTEGRATED
CABINETS
SERVICES
SURGE PROTECTION
48
Emerson Power Equipment And
Environment Monitoring System
Emerson Power Equipment and Environment Monitoring System is applicable to monitoring in real time and managing in unity power supply equipment (power system, battery, UPS, generator and low-voltage distributor), airconditioning equipment and environment(door alarm, temperature, humidity, smoke detection, water immersion, infrared and scene)in telecom exchanges and base stations
After11-year development and optimization, Emerson monitoring system has become a total solution including hardware, software and transmission products. The monitoring solution can be customized to adapt to different regions, different maintenance management mechanisms, different exchanges and different transmission resources. The solution can meet the demands of monitoring the whole power equipment, environment of both fixed and mobile telecom networks
SeriesEmerson power equipment and environment monitoring system
Single version system
ApplicationsPower equipment and environment monitoring systemApplicable to monitoring power equipment, environment in switch site, base stations,transmission
relay stations
Features Of Monitoring Centersupervision center SC consists of database server, console, printer and auxiliary equipmentThe server collects, saves, analyzes and manages all monitoring data from monitoring end office
SU. It gives various alarms (sound & light alarm, email, message, etc.) in case of monitored object's
failure
Fexible Transmission NetworkingMonitoring center SC, monitoring station SS and monitoring end office SU can form a wide area
network through IP, 2M, DDN, ISDN, PSTN and WAN
BenefitsReal time alarmsIn case of monitored object's failure,
the monitoring system can give alarm
within 30 seconds
Multiple alarm reportsThere are sound & light alarm, printed
alarm, paging alarm,mobile short
message alarm, E-mail alarm and voice
alarm
Flexible networkingFlexible single or mixed networks can
be set up through CE1, DDN/LL, ISDN,
PSTN and WAN
Supports maintenance managementP r o v i d e s m a i n t e n a n c e a n l y s i s
data,improves maintenance efficiency
and cuts maintenance cost
Real time data collectionThe system operates around the clock
and reports in real time the monitored
e q u i p m e n t a n d e n v i r o n m e n t ' s
conditions. The system provides first-
hand data to evaluate equipment
conditions.
Wide-range monitored objectsThe monitored objects include HV
a n d L V d i s t r i b u t i o n e q u i p m e n t ,
power system, air conditioning,diesel
generator, battery and UPS; and also
include environment data in relation
to temperature, humidity, water
immersion, smoke and door
49
Business-Critical Continuity™
Communication Solution of
Monitoring System
IP Networking
Features:Using the available
TCP/IP network in site
Supportive of HTTP, TELNET, FTP
Remote debugging and upgrade
Applicable to:IDC room, MSC room, 3G base station, GPRS and CDMA site
Server
LAN
IDU IDU
IDU
IDUIDU
IDU
E1 E1
BRG-POOL
LAN
IDUIDU IDUIDU IDU IDU
Console
Host
IP network
Server Console
Host
Emerson Power Equipment And Environment
Monitoring Software V4.39
Emerson IP Video Monitoring Software
50
Monitoring
Solution of large siteThe SU has IDU and sensors
Applicable to: exchange station, switch centers ( MSC)
Monitored equipment: HV and LV, generator diesel, AC distribution, rectifier, DC distribution,
battery strings,DC converter, inverters and air-conditioner, it can also be applied to acquire
theenvironment data, such as smoke detector, temperature and humidity sensor, access control
andwater detector
solution of small siteThe SU has IDU and sensors
Applicable to: base station (BTS)
Monitored equipment: Low Voltage, DC power, air-conditioner, temperature and humidity sensor,
diesel level, smoke detector, door accessl and water detector
Low Voltage Distribution
DC Power
Air Condition
Battery
Generator
IDU-HOST
Transmission
DC PowerDC Power
Monitoring Center
Intrusion detector For Door
Smoke Detector
Water Leakage
Temperature And Humidity
diesel level
Communication linePower line
Transmission
IDU-HOSTdiesel leveldiesel level
Intrusion detector
Smoke Detector
Water Leakage
Temperature And Humidity
A i r Condition
DC Power
Power meter
51
Business-Critical Continuity™
IDU series product specificationsmodel BOM Description Functions
IDU-HOST 02311425 IDU host
10 AI inputs (compatible with digital signals), 4 DI inputs, 1 THS
temperature/humidity input channel, 4 relay outputs, with 4 serial
ports, 2 battery group voltage channels, 1 Ethernet port, 1 USB port and
2 expansion slots
IDU-BAT1 02311434Battery board 1
(1 battery group)
Capable of monitoring 24 battery cells, 1 charge/discharge current,
auto-switchover among measurement ranges of 2V, 6V and 12V
IDU-BAT2 02311427Battery board 2
(2 battery groups)
capable of monitoring 48 battery cells, 2 charge/discharge currents,
auto-switchover among measurement ranges of 2V, 6V and 12V
IDU-BRG1 02311438E1-IP network bridge
communication board
2 Ethernet ports (LAN), 1 E1 port (point-to-point, cannot be upgraded
to double loop
IDU-BRG2 02311429Double E1-IP network bridge
communication board2 Ethernet ports (LAN), 2 E1 ports (supportive of double loop)
IDU-THS 33030018External THS temperature/
humidity sensor
Temperature measurement range: -10℃~50℃. Precision: +/-2℃Humidity measurement range: 5~95%RH. Precision: +/-5% (20~
80%RH, 25℃)
IDU series product mechanical specificationsName Sizes Weight
IDU-HOST 440 ± 1mm × 295 ± 1mm × 44 ± 1mm ≤5kg
IDU-BAT1 122 ± 1mm × 185 ± 1mm × 1.6mm ≤0.5kg
IDU-BAT2 122 ± 1mm × 185 ± 1mm × 1.6mm ≤0.5kg
IDU-BRG2 122 ± 1mm × 185 ± 1mm × 1.6mm ≤0.5kg
BRG-POOL 440 ± 1mm × 295 ± 1mm × 44 ± 1mm ≤5kg
The features of IDU includeIP-network based, supportive of TCP/IP and network protocols such as HTTP, TELNET, FTP, TFTP
and DHCP
TELNET remote debugging
Highly integrated, with superb processing and storing ability of bottom data
Integrated connection with multiple intelligent devices
Low cost image monitoring solution (USB image and anti-burglary)
High standard lightning protection for all ports. Built-in SPDs are used for all ports, with lightning
protection ability 2-times higher than the international standard
Hardware self-diagnostic ability, including detection of E1 cable status, detection of board
insertion fault, and measurement of CPU usage
Network management function: IP flux statistics, IP contradiction auto-detection, and network
topology structure
Remote on-line upgrading of software
IP networking mode, supportive of transmission modes of double loop, ADSL and E1
Supportive of ADSL static IP address
52
Monitoring
BRG-POOLBRG-POOL bridge pool ( BRG-POOL) is conversion device for E1-IP transfer function. It provides
eight independent E1-IP transfer channels and can be flexibly configured through CONSOLE
portaccording to the actual application conditions and meet the requirements of different
networkingmodes
BRG-POOL specificationsmodel Voltage input range Power
BRG-POOL -38V ~ -60Vdc <20W
model Dimensions Weight
BRG-POOL 440mm × 295mm × 44mm < 5kg
parameters Transmission distance
10/100M, half/full-duplex self-adaptable, RJ45 port,
Ethernet cable intercross function100m max.
53
Business-Critical Continuity™
Making power conversion easy for IT and
communications equipment. We deliver a broad
offering of Astec® and Artesyn® solutions,
including AC/DC and DC/DC power supplies,
adapters,chargers and power accessories.
EMBEDDED POWER.Yet another way Emerson
Network power enables Business-Critical
Continuity™.
EMBEDDED POWER
EMERSON NETWORK POWER.
THE GLOBAL LEADER IN ENABLING
BUSINESS-CRITICAL CONTINUITY.™
AC POWER
CONNECTIVITY
DC POWER
EMBEDDED COMPUTING
EMBEDDED POWER
MONITORING
OUTSIDE PLANT
POWER SWITCHING
& CONTROLS
PRECISION COOLING
RACKS & INTEGRATED
CABINETS
SERVICES
SURGE PROTECTION
54
GIE4805/2A/500-2Mini Power System
Key Features1 U Height and designed for 19” racks
Integrated Battery Low Voltage Disconnection function
GIE4805/2A/500-2Nominal system voltage: -48 V
System rated output power @ - 54 V: 540 W
Rectifier rated output power @ - 54 V: 270 W
DC distribution branchBranch 1 10A(FUSE)
Branch 2 10A(FUSE)
Battery 10A(FUSE)
AC input range: 90-264 V AC
Safety EN 60950
Sub rack dimensions (H x W x D): 43 x 482 x240mm
Key BenefitsSpace efficient solution with all functions integrated
55
Business-Critical Continuity™
GEPS4820F/01-10/22-EN Mini Power System
Key Features1 U Height and designed for 19”racks
Integrated LVD and priority load
GEPS4820F/01-10/22-ENNominal system voltage: - 48 V
System rated output power @ - 54 V: 1600 W
Rectifi er rated output power @ - 54 V: 800 W
DC distribution branchBranch 1 10A(FUSE)
Branch 2 20A(FUSE)
Battery 20A(FUSE)
AC input range: 90-290 V AC
Safety EN 60950, UL 60950
Sub rack dimensions (H x W x D): 45.6 x 482.6 x 325mm
Key BenefitsSpace effi cient solution with all functions integrated
56
Embedded Power
GIE4815/2A/1.7KWMini Power System
Key Features2 U Height and designed for 19”racks
Integrated AC distribution, LVD and priority load
Remote monitoring and dry contacts
GIE4815/2A/1.7KWNominal system voltage: - 48 V
System rated output power @ - 54 V: 1700 W
Rectifier rated output power @ - 54 V: 850 W
DC distribution branchBranch 1,2 5A(FUSE)
Branch 3 10A(FUSE)
Branch 4,5 20A(FUSE)
Battery 50A(MCB)
AC input range: 90-290 V AC
Safety EN 60950, UL 60950
Sub rack dimensions (H x W x D): 88 x 483 x 350mm
Key BenefitsSpace efficient solution with all functions integrated
57
Business-Critical Continuity™
GIE4815/3A/2.55KW Mini Power System
Key Features3 U Height and designed for 19”racks
Remote monitoring and dry contacts
Integrated AC distribution, surge protection, LVD and priority load
GIE4815/3A/2.55KWNominal system voltage: - 48 V
System rated output power @ - 54 V: 2550 W
Rectifi er rated output power @ - 54 V: 850 W
DC distribution branchBranch 1, 10A(MCB)
Branch 2,3 20A(MCB)
Branch 4, 50A(MCB)
Battery 63A(MCB)
AC input range: 90-290 V AC
Safety EN 60950, UL 60950
Sub rack dimensions (H x W x D): 133 x 465 x 360mm
Key BenefitsSpace effi cient solution with all functions integrated on one shelf
Robust and well proven design for tropical climates
Provides reliable DC supply
58
Embedded Power
GIE4820/3A/3.45KWMini Power System
Key Features3 U Height and designed for 19”racks
Remote monitoring and dry contacts
Integrated AC distribution, surge protection, LVD and priority load
GIE4820/3A/3.45KWNominal system voltage: - 48 V
System rated output power @ - 54 V: 3450 W
Rectifier rated output power @ - 54 V:1150 W
DC distribution branchBranch 1, 10A(MCB)
Branch 2,3 20A(MCB)
Branch 4, 50A(MCB)
Battery 63A(MCB)
AC input range: 90-290 V AC
Safety EN 60950, UL 609 50
Sub rack dimensions (H x W x D): 133 x 465 x 360mm
Key BenefitsSpace efficient solution with all functions integrated on one shelf
Robust and well proven design for tropical climates
Provides reliable DC supply
59
Business-Critical Continuity™
Emerson Network Power Co., Ltd.No. 1 Kefa Rd., Science & Industry ParkNanshan District 518057, Shenzhen, ChinaPhone: +86-755-8601-0808
Emerson Network Power. The global leader in enabling Business-Critical Continuity™. www.emersonnetwork.com.cn
Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co.
E-X6210486-0708
AC Power Systems Embedded Power Outside Plant
Connectivity Inbound Power Precision Cooling
DC Power Systems Integrated Cabinet Solutions Site Monitoring and Services