Power Supply

for VENUE FOH Rack and VENUE Stage Rack

Legal Notices

This guide is copyrighted ©2010 by Avid Technology, Inc., (hereafter “Avid”), with all rights reserved. Under copyright laws, this guide may not be duplicated in whole or in part without the written consent of Avid.

003, 96 I/O, 96i I/O, 192 Digital I/O, 192 I/O, 888|24 I/O, 882|20 I/O, 1622 I/O, 24-Bit ADAT Bridge I/O, AudioSuite, Avid, Avid DNA, Avid Mojo, Avid Unity, Avid Unity ISIS, Avid Xpress, AVoption, Axiom, Beat Detective, Bomb Factory, Bruno, C|24, Command|8, Control|24, D-Command, D-Control, D-Fi, D-fx, D-Show, D-Verb, DAE, Digi 002, DigiBase, DigiDelivery, Digidesign, Digidesign Audio Engine, Digidesign Intelligent Noise Reduction, Digidesign TDM Bus, DigiDrive, DigiRack, DigiTest, DigiTranslator, DINR, D-Show, DV Toolkit, EditPack, Eleven, HD Core, HD Process, Hybrid, Impact, Interplay, LoFi, M-Audio, MachineControl, Maxim, Mbox, MediaComposer, MIDI I/O, MIX, MultiShell, Nitris, OMF, OMF Interchange, PRE, ProControl, Pro Tools M-Powered, Pro Tools, Pro Tools|HD, Pro Tools LE, QuickPunch, Recti-Fi, Reel Tape, Reso, Reverb One, ReVibe, RTAS, Sibelius, Smack!, SoundReplacer, Sound Designer II, Strike, Structure, SYNC HD, SYNC I/O, Synchronic, TL Aggro, TL AutoPan, TL Drum Rehab, TL Everyphase, TL Fauxlder, TL In Tune, TL MasterMeter, TL Metro, TL Space, TL Utilities, Transfuser, Trillium Lane Labs, Vari-Fi Velvet, X-Form, and XMON are trademarks or registered trademarks of Avid Technology, Inc. Xpand! is Registered in the U.S. Patent and Trademark Office. All other trademarks are the property of their respective owners.

Product features, specifications, system requirements, and availability are subject to change without notice.

Guide Part Number 9321-62793-00 REV B 08/10

Contents

Chapter 1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

What’s Included . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Chapter 2. FOH Rack Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Chapter 3. Stage Rack Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Stage Rack Main Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Stage Rack Redundant Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Environmental Compliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

EMC (Electromagnetic Compliance). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Contents iii

Power Supplyiv

Chapter 1: Introduction

This guide explains how to replace the main power supply or the redundant power supply in the VENUE FOH Rack or the VENUE Stage Rack.

Before You BeginBefore you install your power supply, do the following:

• Make sure all hardware is powered off and all cables are disconnected.

• Place the Stage Rack or FOH Rack in a well-lit area, free of excessive dust and dirt.

The power supply options are easy to install and require only a small or medium-sized screwdriver (#1 or #2 Phillips-head).

What’s Included

FOH Rack Power Supply

The complete FOH Rack Power Supply package includes the following:

• FOH Rack Power Supply unit

• Power Supply guide

• AC power cable (IEC)

Stage Rack Power Supply

The complete Stage Rack Power Supply package includes the following:

• Stage Rack Power Supply unit

• Power Supply guide

• AC power cable (IEC)

Chapter 1: Introduction 1

Power Supply2

Chapter 2: FOH Rack Power Supply

This chapter explains how to remove and replace either the main or the redundant power supply in the FOH Rack. The complete process should take approximately 15 minutes.

To remove and replace a power supply from the FOH Rack:

1 Shut down your VENUE system, and turn off power to the FOH Rack.

2 Disconnect all cables from the FOH Rack. Remove any USB disks or accessories plugged in to the connectors on the out-side of the rack.

3 Using a #1 Phillips screwdriver, loosen the mounting screw for the power supply you wish to replace.

4 Slide the old power supply module out of the slot.

5 Slide the new, replacement power supply into the slot until it is fully seated and flush with the outside of the FOH Rack.

Loosening the mounting screw

Sliding the power module into the slot

6 Tighten the power supply’s mounting screw so that it locks to the chassis.

7 Check to make sure the power supply is fully seated and se-cured by gently pulling on its swivel handle and making sure the unit cannot slide out.

To verify installation:

1 Connect an AC power cable from the newly installed power supply’s corresponding AC port (next to the power supply’s power switch) to a power source.

2 Turn the power switch on the power supply to the ON posi-tion.

3 Press the power switch located on the front of the rack to power up your VENUE system. When successfully installed, the lights on the newly installed power supply are lit solid.

Chapter 2: FOH Rack Power Supply 3

Power Supply4

Chapter 3: Stage Rack Power Supply

This chapter explains how to remove and replace the main power supply and the redundant power supply in the Stage Rack. The complete process should take approximately 30 minutes per power supply.

Stage Rack Main Power SupplyTo replace the main power supply, you must first remove some Stage Rack Input (SRI) cards.

To remove the main power supply:

1 Shut down the VENUE system, and turn off power to the Stage Rack.

2 Disconnect all cables from the Stage Rack.

3 Remove the back panel using a #1 Phillips screwdriver to re-move the 18 screws that secure the panel to the rack, and lift the panel away from the rack.

Figure 1. Stage Rack back panel

Removeback panel

4 Remove the SRI cards that cover the main power supply as indicated in Figure 2 by doing the following:

• Inside the rack, disconnect the ribbon cables by pressing the retaining clips at the top and bottom of the ribbon sockets outward to release the ribbon cable from each card. Leave the ribbon cable in place (do not disconnect additional cards, and do not remove the entire ribbon ca-ble).

• Use a Phillips screwdriver to unscrew the internal mount-ing screw for each card you disconnected in the previous step.

Figure 2. Remove the noted SRI cards that cover the main power supply

Figure 3. Removing the mounting screws before removing Stage Rack I/O cards

Press to release ribbon cable

Chapter 3: Stage Rack Power Supply 5

• From the front of the Stage Rack, using a #1 Phillips screwdriver remove the four screws noted in Figure 4 for each card you are removing.

• Carefully remove the cards from the rack. For each card, use two hands; one to push forward (from the back of the Stage Rack, and the other to pull the card out (from the front of the Stage Rack). Make sure to note which card be-longs in which slot to simplify the reinstallation of the cards.

5 From the back of the Stage Rack, carefully remove the two cable ties indicated in Figure 5 that are used to secure the power supply harness to the Stage Rack.

Figure 4. Remove the noted screws for each card

Figure 5. Remove the noted cable ties

Power Supply6

6 Carefully disconnect the 24-pin power supply cable connec-tor from the Controller card, shown in Figure 6.

7 Remove the two silver screws on either side of the power switch, as shown in Figure 7.

Figure 6. Disconnect the noted power supply cable connector from the Controller card

Figure 7. Removing the two screws on either side of the power switch

8 Remove the fours crews indicated in Figure 8 that secure the power supply to the rack’s chassis.

9 Lift the power supply out of the rack.

To replace the power supply:

1 Carefully place the new power supply in the rack. Slide the power supply into place so that its mounting holes line up with the holes in the rack chassis. Make sure the power cables for the new power supply are free to reach their power socket to the left and above the new module.

2 Replace the four screws that secure the power supply to the rack’s chassis.

3 Replace the two screws on either side of the power switch.

4 Connect the new power supply’s 24-pin power supply cable connector to the bottom power port on the Controller card, as noted in Figure 6. Orient the cable correctly so that it snaps into the socket.

Figure 8. Remove the four noted screws that secure the power supply to the rack

Figure 9. Lifting the power supply out of the rack

5 Reinstall the SRI cards you removed earlier by doing all of the following:

• Carefully insert each SRI Input Card into position in the Stage Rack. There is a guide hole for each card to fit into at the back of the unit, as noted in Figure 10

• Reattach the ribbon cable to each of the Stage Rack I/O cards you replaced. Gently press the ribbon cable into each card socket, and make sure the connector tabs spring back to their “locked” position.

• Reattach each card’s internal mounting screw that you removed in Step 4 on page 5.

• On the front of the rack, reattach the four screws that se-cure each card to the rack.

6 Reattach the back panel of the Stage Rack.

To verify installation:

1 Connect an AC power cable from the newly installed power supply’s corresponding AC port (underneath the power sup-ply's power switch) to a power source.

2 Turn the power switch on the power supply to the ON posi-tion. When successfully installed, the power switch lights green.

Figure 10. Stage Rack guide holes for IO cards

Chapter 3: Stage Rack Power Supply 7

Stage Rack Redundant Power SupplyDepending on your configuration, you may have to remove some Stage Rack Output (SRO) cards to replace the redundant power supply.

To remove the redundant power supply:

1 Shut down the VENUE system, and turn off power to the Stage Rack.

2 Disconnect all cables from the Stage Rack.

3 Remove the back panel using a #1 Phillips screwdriver to re-move the 18 screws that secure the panel to the rack, and lift the panel away from the rack.

4 Remove any SRO cards that cover the main power supply as indicated in Figure 12 by doing the following:

• Disconnect the ribbon cables by pressing the retaining clips at the top and bottom of the ribbon sockets outward to release the ribbon cable from each card. Leave the rib-bon cable in place (do not disconnect additional cards, and do not remove the entire ribbon cable).

Figure 11. Stage Rack back panel

Figure 12. Remove the noted SRO cards that cover the main power supply

Removeback panel

Power Supply8

• Use a Phillips screwdriver to unscrew the internal mount-ing screw for each card you disconnected in the previous step.

• From the front of the Stage Rack, using a #1 Phillips screwdriver remove the four screws noted in Figure 14 for each card you are removing.

• Carefully remove the cards from the rack. For each card, use two hands; one to push forward (from the back of the Stage Rack, and the other to pull the card out (from the front of the Stage Rack). Make sure to note which card be-longs in which slot to simplify the reinstallation of the cards.

5 Carefully remove any cable ties that are used to secure the redundant power supply power cable to the Stage Rack.

Figure 13. Removing the mounting screws before removing Stage Rack I/O cards

Figure 14. Connecting the new power module to the Stage Rack

Press to release ribbon cable

6 Carefully disconnect the 24-pin redundant power supply ca-ble connector from the Controller card, shown in Figure 15.

7 Remove the two silver screws on either side of the power switch, as shown in Figure 16.

Figure 15. Disconnect the noted power supply cable connector from the Controller card

Figure 16. Removing the two screws on either side of the power switch

8 Remove the fours crews indicated in Figure 17 that secure the power supply to the rack’s chassis.

9 Lift the power supply out of the rack.

To replace the power supply:

1 Carefully place the new power supply in the rack. Slide the power supply into place so that its mounting holes line up with the holes in the rack chassis. Make sure the power cables for the new power supply are free to reach their power socket to the left and above the new module.

2 Replace the four screws that secure the power supply to the rack’s chassis.

3 Replace the two screws on either side of the power switch.

4 Connect the new power supply’s 24-pin power supply cable connector to the top power port on the Controller card, as noted in Figure 15. Orient the cable correctly so that it snaps into the socket.

5 Reinstall the SRO cards you removed earlier by doing all of the following:

Figure 17. Remove the four noted screws that secure the power supply to the rack

Figure 18. Lifting the power supply out of the rack

Chapter 3: Stage Rack Power Supply 9

• Carefully insert each SRI Input Card into position in the Stage Rack. There is a guide hole for each card to fit into at the back of the unit, as noted in Figure 19

• Reattach the ribbon cable to each of the Stage Rack I/O cards you replaced. Gently press the ribbon cable into each card socket, and make sure the connector tabs spring back to their “locked” position.

• Reattach each card’s internal mounting screw that you removed in Step 4 on page 8.

• On the front of the rack, reattach the four screws that se-cure each card to the rack.

6 Reattach the back panel of the Stage Rack.

To verify installation:

1 Connect an AC power cable from the newly installed power supply’s corresponding AC port (located underneath the power supply's power switch) to a power source.

2 Turn the power switch on the power supply to the ON posi-tion. When successfully installed, the power switch lights green.

Figure 19. Stage Rack guide holes for IO cards

Power Supply10

Appendix A: Compliance Information

Environmental Compliance

Disposal of Waste Equipment by Users in the European Union

This symbol on the product or its packaging indicates that this product must not be disposed of with other waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city recycling office or the dealer from whom you purchased the product.

Proposition 65 Warning

Perchlorate Notice

This product may contain a lithium coin battery. The State of California requires the following disclosure statement: “Perchlorate Material – special handling may apply, See www.dtsc.ca.gov/hazardouswaste/perchlorate.”

Recycling Notice

This product contains chemicals, including lead, known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.

EMC (Electromagnetic Compliance)These models FOH Rack and Stage Rack complies with the following standards regulating interference and EMC:• FCC Part 15 Class B• EN 55103-1 E3• EN 55103-2 E3• AS/NZS CISPR 22 Class B• CISPR 22 Class B

FCC Compliance for United States

Radio and Television Interference

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.

DECLARATION OF CONFORMITYWe, Avid, 2001 Junipero Serra BoulevardDaly City, CA 94014-3886, USA650-731-6300declare under our sole responsibility that the productsFOH Rack and Stage Rackcomply with Part 15 of FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Communication StatementNOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and

receiver.• Connect the equipment into an outlet on a circuit

different from that to which the receiver is connected.• Consult the dealer or an experienced radio/TV technician

for help.Any modifications to the unit, unless expressly approved by Avid, could void the user's authority to operate the equipment.

Appendix A: Compliance Information 11

Australian Compliance

Canadian Compliance

This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.

Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.

CE Compliance

(EMC and Safety)

Avid is authorized to apply the CE (Conformité Europénne) mark on this compliant equipment thereby declaring conformity to EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC.

Avid

Power Supply 12

Important Safety Instructions

1) Read these instructions.

2) Keep these instructions.

3) Heed all warnings.

4) Follow all instructions.

5) Do not use this equipment near water.

6) Clean only with dry cloth.

7) Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8) Do not install near any heat sources such as radiators, heat registers, stoves, or other equipment (including amplifiers) that produce heat.

9) Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

10) Protect power cords from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the equipment.

11) Only use attachments/accessories specified by the manufacturer.

Avid2001 Junipero Serra Boulevard Daly City, CA 94014-3886 USA

Technical Support (USA)Visit the Online Support Center at www.avid.com/support

Product InformationFor company and product information, visit us on the web at www.avid.com