Power Shelf Input Power Connector…refresh • Decrease total cost of ownership What do we need...
Transcript of Power Shelf Input Power Connector…refresh • Decrease total cost of ownership What do we need...
![Page 1: Power Shelf Input Power Connector…refresh • Decrease total cost of ownership What do we need now? Specifications RACK & POWER • Input connector that can handle all power and](https://reader033.fdocuments.us/reader033/viewer/2022060213/5f053b447e708231d411ef59/html5/thumbnails/1.jpg)
Power Shelf Input Power
Connector
Will StewartData Center Segment ManagerHARTING
Rack & Power
![Page 2: Power Shelf Input Power Connector…refresh • Decrease total cost of ownership What do we need now? Specifications RACK & POWER • Input connector that can handle all power and](https://reader033.fdocuments.us/reader033/viewer/2022060213/5f053b447e708231d411ef59/html5/thumbnails/2.jpg)
Agenda
Specifications
RACK & POWER• HARTING Overview
• Open Rack v2 Power Architecture
• Universal PDU Success Story
• Universal Power Shelf Benefits
• Input Power Connector Concept
• Questions
![Page 3: Power Shelf Input Power Connector…refresh • Decrease total cost of ownership What do we need now? Specifications RACK & POWER • Input connector that can handle all power and](https://reader033.fdocuments.us/reader033/viewer/2022060213/5f053b447e708231d411ef59/html5/thumbnails/3.jpg)
HARTING Facts & Figures
Specifications
RACK & POWER~$900Min turnover
about 5,000 employees
13production plants
founded in
1945
Company HQ in
Espelkamp , Germany
100 %owned by the Harting family
worldwide
44sales companies
![Page 4: Power Shelf Input Power Connector…refresh • Decrease total cost of ownership What do we need now? Specifications RACK & POWER • Input connector that can handle all power and](https://reader033.fdocuments.us/reader033/viewer/2022060213/5f053b447e708231d411ef59/html5/thumbnails/4.jpg)
Open Rack v2 Power Architecture
Specifications
RACK & POWERBusway gPDU Power Shelf
![Page 5: Power Shelf Input Power Connector…refresh • Decrease total cost of ownership What do we need now? Specifications RACK & POWER • Input connector that can handle all power and](https://reader033.fdocuments.us/reader033/viewer/2022060213/5f053b447e708231d411ef59/html5/thumbnails/5.jpg)
Current Power Architecture
Specifications
RACK & POWER• Proprietary PDU to power shelf connection
• Limited in power capabilities
• Proprietary design, not in alignment with mission of Open Compute
• Prevents global architecture
![Page 6: Power Shelf Input Power Connector…refresh • Decrease total cost of ownership What do we need now? Specifications RACK & POWER • Input connector that can handle all power and](https://reader033.fdocuments.us/reader033/viewer/2022060213/5f053b447e708231d411ef59/html5/thumbnails/6.jpg)
Varying Power Requirements Prevent Global Architecture
Specifications
RACK & POWER
• 20A
• 12 AWG
• NEMA L22-20P Plug
• 32A
• 10 AWG
• IEC 60309 Plug
Additional architectures can also be found inside these regions
![Page 7: Power Shelf Input Power Connector…refresh • Decrease total cost of ownership What do we need now? Specifications RACK & POWER • Input connector that can handle all power and](https://reader033.fdocuments.us/reader033/viewer/2022060213/5f053b447e708231d411ef59/html5/thumbnails/7.jpg)
Connectorization Success Story
Specifications
RACK & POWER
Microsoft Project Olympus
• Switched from hardwired rPDU to a Universal rPDU
• Lead time dropped from 6-8 weeks to 2 weeks
• Power cables can be re-used
• Simplified supply chain and optimized inventory
![Page 8: Power Shelf Input Power Connector…refresh • Decrease total cost of ownership What do we need now? Specifications RACK & POWER • Input connector that can handle all power and](https://reader033.fdocuments.us/reader033/viewer/2022060213/5f053b447e708231d411ef59/html5/thumbnails/8.jpg)
Power Shelf v3 Proposal
Specifications
RACK & POWER• Remove gPDU
• Cable drop from bus bar connected directly to power shelf
• Streamline and simplify design
• Create one rack architecture that can be used globally
• NEED: OCP AcceptedTM Input Power Connector
![Page 9: Power Shelf Input Power Connector…refresh • Decrease total cost of ownership What do we need now? Specifications RACK & POWER • Input connector that can handle all power and](https://reader033.fdocuments.us/reader033/viewer/2022060213/5f053b447e708231d411ef59/html5/thumbnails/9.jpg)
Benefits
Specifications
RACK & POWER• One rack design used
internationally
• Reduce liability in inventory
• Fewer SKUs, faster deployment
• Retain cables during data hall refresh
• Decrease total cost of ownership
![Page 10: Power Shelf Input Power Connector…refresh • Decrease total cost of ownership What do we need now? Specifications RACK & POWER • Input connector that can handle all power and](https://reader033.fdocuments.us/reader033/viewer/2022060213/5f053b447e708231d411ef59/html5/thumbnails/10.jpg)
What do we need now?
Specifications
RACK & POWER• Input connector that can handle all power and
dimensional requirements
• Industry proven technology leader to innovate and partner for OCP standardization
• OCP AcceptedTM product with OCP Specification
![Page 11: Power Shelf Input Power Connector…refresh • Decrease total cost of ownership What do we need now? Specifications RACK & POWER • Input connector that can handle all power and](https://reader033.fdocuments.us/reader033/viewer/2022060213/5f053b447e708231d411ef59/html5/thumbnails/11.jpg)
Specifications
RACK & POWER
Input Connector Concept
2.027”51.5 mm
5.14”130.6 mm
0.94”24.0 mm
1.42”36.0 mm
Dimensional requirements:
• Height: <1.77” (<45mm)
• Length: <2.56” (<65mm)
• Depth: <2.36” (<60mm)
![Page 12: Power Shelf Input Power Connector…refresh • Decrease total cost of ownership What do we need now? Specifications RACK & POWER • Input connector that can handle all power and](https://reader033.fdocuments.us/reader033/viewer/2022060213/5f053b447e708231d411ef59/html5/thumbnails/12.jpg)
Specifications
RACK & POWER
Input Connector Concept
• Finger protected contacts
• 50A/480V
• Positive latch
• Potential coding
• Can fit four connections on one power shelf
![Page 13: Power Shelf Input Power Connector…refresh • Decrease total cost of ownership What do we need now? Specifications RACK & POWER • Input connector that can handle all power and](https://reader033.fdocuments.us/reader033/viewer/2022060213/5f053b447e708231d411ef59/html5/thumbnails/13.jpg)
Timeline
March 15
• Receive feedback from OCP on conceptual design
Q2 2019
• Finalize design and specification
• Present to Rack and Power subgroup
Q3 2019
• Present specification to Incubation Committee
• Manufacture samples
Q4 2019
• List OCP AcceptedTM
power shelf input connector in OCP Marketplace
![Page 14: Power Shelf Input Power Connector…refresh • Decrease total cost of ownership What do we need now? Specifications RACK & POWER • Input connector that can handle all power and](https://reader033.fdocuments.us/reader033/viewer/2022060213/5f053b447e708231d411ef59/html5/thumbnails/14.jpg)
Specifications
RACK & POWER
More Information
Will Stewart
Data Center Segment Manager
HARTING, Inc. of North America
+1 (224)762-0527
SW1
![Page 15: Power Shelf Input Power Connector…refresh • Decrease total cost of ownership What do we need now? Specifications RACK & POWER • Input connector that can handle all power and](https://reader033.fdocuments.us/reader033/viewer/2022060213/5f053b447e708231d411ef59/html5/thumbnails/15.jpg)
Slide 15
SW1 Stewart, William, 3/11/2019
![Page 16: Power Shelf Input Power Connector…refresh • Decrease total cost of ownership What do we need now? Specifications RACK & POWER • Input connector that can handle all power and](https://reader033.fdocuments.us/reader033/viewer/2022060213/5f053b447e708231d411ef59/html5/thumbnails/16.jpg)