POWER & ENERGY MANAGEMENT SOLUTIONS
CORPORATE CATALOGUE
R
SEPTEMBER 2017
ABOUT USAtandra Energy Pvt. Ltd, is a Chennai based company built on a platform of over 30years of experience in the area of Power & Energy Management.
Our Facilities
Ÿ An ISO 9001:2008 Certified factory Ÿ R&D departments for Embedded designs, Power Electronics and Electro-
magneticsŸ A Software Development department to design, develop and customise
Energy Management Software.
Leading Brand
We offer solutions to industrial and commercial establishments under our popular brand KRYKARD. With over 3,50,000 installations of Power Conditioners and over 100,000 installations of Portable and Panel Load Managers, KRYKARD is one of the leading brands in the area of Energy Management.
These facilities help us respond to the needs of Indian industries in a comprehensive and appropriate manner so that they fully experience the benefits of energy management solutions offered by us.
With over 250 employees and a network of branches across the country, we areequipped to reach and service the needs of our customers.
Our Sales & Service Loca�onsacross India
Ahmedabad | Bengaluru | Bhopal | Chennai | Coimbatore Chandighar | Erode | Guntur | Hosur | Hubli | HyderabadKochi | Kolkata | Madurai | Mumbai | Nagpur | New Delhi
Pune | Rajkot | Tiruppur | Vishakapatnam
PO
RTA
BLE
LO
AD
M
AN
AG
ERS
PAN
EL
LO
AD
M
AN
AG
ERS
AC
TIV
E FI
LTERS
HA
RM
ON
ICC
LAM
PS
ME
ASU
RE
PR
OTEC
T
PAGE 4
PAGE 5
PAGE 5
PAGE 6
PAGE 7
PAGE 20
PAGE 10
PAGE 12
PAGE 14
PAGE 15
PAGE 16
PAGE 17
PAGE 18
PAGE 24
PAGE 22
PAGE 26
EN
ERG
Y
MA
NA
GEM
EN
T
SOFT
WA
RE
CO
NSE
RV
E
PAGE 28
PAGE 30
SOME OF OUR CLIENTS PAGE 32
ALM 36 4 CT comprehensive Power Quality & Energy Audit Analyser
ALM 33 3 CT comprehensive Power Quality & Energy Audit Analyser
ALM 31
ALM 20 3 CT handy Harmonic & Energy Audit Analyser
ALM 10
F205/407/607 Range of 3 clamps for power and harmonic studies
ENERIUM 3000.2 Class Harmonics, Power & Energy meter with I/Os
DiGi 7200.5 Class Harmonics, Power & Energy Meter With I/Os
DiGi 620/620H
DiGi 520/520H
0.5 Class Harmonics, Power & Energy Meter
0.5 Class Load Management Meter
DiGi 250Class .0 Power & Energy meter1
Multy 4Multi Channel Power & Energy meter
Thermal ImagerUp to 250°C
Active Harmonic Filter30A to 300A
3-Phase, I-Phase Air Cooled & Oil Cooled Servo Stabilisers
From kVA to 3500 kVA1
Isolation and Auto Transformers
1kVA to 500 kVA
For saving energy on lighting loads in buildings and factories
From 5kVA to 500 kVA1
PC based and Web-based Software S
ERV
OST
ABIL
ISERS
LIG
HTI
NG
EN
ERG
YSA
VERS
ISO
LATI
ON
TRA
NSF
ORM
ERS
THERM
AL
IMA
GER
1 CT handy Harmonics & Energy Audit Analyser
3 CT comprehensive Power Quality & Energy Audit Analyser
ALM 36
ALM 33
Comprehensive 4 CT Power Quality & Energy Analyser
Comprehensive 3 CT Harmonic & Energy Analyser
• Complies with IEC 61000-4-30 measurement standard under Class B.
• High electrical safety standards as IEC 61010, CAT IV 600V/ CAT III 1000V.
• Multi tasking ability for simultaneous data logging, alarm recording, inrush current recording, harmonic analysis and transient recording.
• Complete freedom to select parameters, time interval and duration.
• Capture up to 16,362 alarms on any of 40 different types of parameters (½ cycle RMS for V, U & I; 1s RMS for other parameters)
• Record up to 50 screenshots (pictures)
• Capture up to 210 transients (4 cycles each)
• Capture Inrush Current (capture Current & Voltage waveforms)
• Phasor Diagram with Phase Angles
• DataView software for download and report generation as per EN50160
• Direct recording on PC with DataView software
• 4 sets of pre-recorded conguration for data logging
• Battery backup up to 13 hours for operation & 40 hours for data logging
• Auto CT recognition, accepts up to 9 different CTs for measurement
• CT/PT ratios are eld programmable
• Flexibility to set different Transient threshold levels for V & I on each phase
• Hindi Language option for operation
• Colour TFT having clear wide angle view and Night-view facility
• Complies with IEC 61000-4-30 measurement standard under Class B (only in ALM 33)
• High electrical safety standards as IEC 61010, CAT IV 600V/ CAT III 1000V
• Multi tasking ability for simultaneous data logging, alarm recording, harmonic analysis and transient recording (ALM 31 does not offer alarms and transients)
• Complete freedom to select parameters, time interval and duration
• Record up to 4,662 alarms (½ cycle setting for V & I, 1s RMS for other values) of 10 different types in ALM 33
• Record up to 12 snapshots (pictures)
• Capture up to 51 transients in ALM 33 (4 cycles each)
• Phasor diagram with Phase Angles
• DataView software for download and report generation as per EN50160
• Direct recording on PC with DataView software
• 4 sets of pre-recorded conguration for data logging
• Battery backup up to 13 hours for operation & 40 hours for data logging
• Auto CT recognition, accepts upto 9 diferent CTs for measurement
• CT/PT ratios are eld programmable
• 4 sets of pre-recorded conguration for data logging
• Flexibility to set different threshold levels for V & I on each phase
• Hindi Language option for operation
• Colour TFT having clear wide angle view and Night-view facility
• Voltage, Current, Frequency
• kW, kVA, kVAr, Distored kVAr
• PF, Cosø, Tanø
• 4 Quadrant Energy: Wh, VAh, VArh, Dh (Distortion Energy)
• Short-term Flicker, FHL, CF, K-Factor
• THDf, THDr on V, U & I (THDr only in ALM 33)
•
• Sequence of Harmonics (only in ALM 33)
• V & I Transients (only in ALM 33)
MEASURES
SALIENTFEATURES
SALIENTFEATURES
• Voltage, Current, Frequency
• kW, kVA, kVAr, Distorted kVAr
• Wh, VAh, VArh, Dh (Distortion Energy)
• PF, Cosø, Tanø
• Short-term & Long-term Flicker, CF, K-Factor, FHL
• THDf & THDr on V, U & I
•
• Sequence of Harmonics
• V & I Transients
• Inrush Current
MEASURES
IEC 61000-4-30 Class B
IEC 61010 - CAT IV 600V / CAT III 1000 V
True Inrush
2GB Memory
Mul�-tasking
9 Current Clamp op�ons
8 types of connec�ons
measure���protect���conserve
Language op�onहंद�
ALM 36 ALM 33 & 31
& ALM 31IEC 61010 - CAT IV 600V / CAT III 1000V
V & I transients (ALM 33)
½ cycle Alarms (ALM 33)
Mul�-tasking
9 Current Clamp op�ons
Language op�onहंद�
54 measure���protect���conserve
Harmonics up to 50 order on V, U, I, Neutral Current and VAth
Harmonics up to 50 orderth
6 7
• High electrical safety standards as IEC 61010, CAT III 600V
• Multi tasking ability for simultaneous data logging and harmonic analysis
• Complete freedom to select parameters, time interval and duration
• Record up to 8 screenshots (pictures)
• Capture Inrush Current (capture Current & Voltage waveforms)
• DataView software for download and report generation
• Direct recording on PC with DataView software
• 4 sets of pre-recorded conguration for data logging
• Battery backup up to 8 hours for operation & 40 hours for data logging
• Auto CT recognition, accepts up to 8 different CTs for measurement
• High electrical safety standards as IEC 61010, CAT IV 600V / CAT III 1000V
• Magnetic Latch for instant mounting and removal on electrical panels
• 17 types of electrical connections possible
• Bluetooth interface, USB and Ethernet communication
• Data logging & data retrieval possible directly from SD card
• Auto CT recognition, accepts up to 9 different CTs for measurement
• Simultaneous data logging and harmonic analysis
• Complete freedom to select time interval and duration
• DataView software for data download / retrieval and report generation
• Android App for instrument conguration and viewing of real-time data through Bluetooth
SALIENT
FEATURES
SALIENTFEATURES
• Voltage, Current, Frequency
• kW, kVA, kVAr (with, without harmonics)
• PF, Cosø, Tanø
• Wh, VAh, VArh
• Short-term Flicker, Crest Factor, K-Factor
• • Inrush Current
• AC/DC Voltage
• AC/DC Current
• Frequency - 50, 60 & 400 Hz
• V & I Crest Factor
• kW, kVA, kVAr
• PF, Cosø, Tanø
• Wh,VAh, VArh
• THDf on V, U, I, In
•
MEASURES
Bluetooth, Ethernet and USB
17 types of connec�ons
Magne�c Latch for instant moun�ng
Removable SD card
Android app for real-�me views and configura�on
½ cycle Alarms
1-Phase & 3-Phase Balanced
Motor Inrush
Multi-tasking
ALM 10ALM 20
ALM 10Convenient tool for load studies - 1 CT analyser
ALM 20Ideal handy tool for eld studies - 3 phase 3 CT analyser
MEASURES
measure �protect��conservemeasure���protect���conserve
Harmonics up to 50 order on V, U, I & Inth
THDf on V & I, Harmonics up to 50 orderth
98
PORTABLE LOAD MANAGERS PORTABLE LOAD MANAGERS
Technical Specications ALM 36 ALM 33
Number of channels 4U/4I 3U/3I
Voltage (TRMS AC + DC) 2V to 2000V ph-ph /
Voltage ratio Up to 500 kV
Current (TRMS AC + DC)
Current ratio Up to 60 kA
Frequency
Power values W, VA, VAr, VAD, PF, DPF, cos ø, tan ø
Energy values Wh, VAh, VArh, Dh
Harmonics, THD
Transients 210 50
Flicker (Pst & Plt) Pst & Plt Pst
Inrush mode > 10 minutes 4 periods
Alarms 16,362 events 4,662 events
Storage Capacity for a selection of parameters at 1s interval 2 weeks to several years A few days to several weeks
Phasor Diagram Yes - on instrument & on PC
Display Colour 1/4 VGA TFT screen, 320 x 240, diagonal 148mm
Capture of screen snapshots 50 12
Electrical safety IEC 61010, 1000V CAT III / 600V CAT IV
Protection IP53 / IK08
Communication interface USB
Battery/ Battery life 9.6 V NiMh rechargeable battery / up to 13 hours
Dimensions / Weight 200 x 250 x 70 mm / 2.0 kg
2V to 1000V ph-N
5 mA to 10,000 Aac/
10 mA to 5000 Adc ( depending on Clamp)
42.5 to 69 Hz
Voltage Accuracy
Current Accuracy
+- (0.5% + 1V)
+- 0.5% + CT Accuracy
Active Power Accuracy (kW) +- 1%
AMPFLEX AMPFLEX AMPFLEXInternal Dia: 140 mm Internal Dia: 250 mm Internal Dia: 70 mm Internal Dia: 20 mm Internal Dia: 20 mm Internal Dia: 52 mm Internal Dia: 39 mm Internal Dia: 72 mm Internal Dia: 11.8 mm
Current Range: Current Range: Current Range:
10000 Aac 10000 Aac 10000 Aac 200 Aac
MINI MN 93 MN 93A
Current Range: Current Range: Current Range: Current Range: Current Range: Current Range:
5 Aac & 00 Aac1 1000 Aac 1 1000 Aac & 300 Adc
C 193 PAC 93 J93
3500 Aac / 50 A to 5000 Adc
E3N
100 Aac / dc
measure���protect���conserve measure �protect��conserve
ALM 31 ALM 20 ALM 10
3U/3I 1U/1I
2 V to 2000 V ph-ph / 5V to 2000V ph-ph / 6V to 660V5V to 1000V ph-N
Up to 500 kV Up to 650 kV Through Software
5mA to 10,000 Aac / 50 mA to 5,000 Adc (depending on Clamp)
Up to 60 kA Up to 25 kA Up to 2.999 kA
42.5-69Hz, 340 - 460Hz 42.5 to 69Hz
W, VA, VAr, VAD, PF, DPF, cosø, tanø
Wh, VAh, VArh, Dh Wh, VAh, VArh
x x x
Pst x Pst
x x >17 secs
x x 4,000 events
4 hours to 2 weeks Few days to few weeks 1 hour to few weeks
Yes - on instrument & on PC Yes - on PC x
Colour 1/4 VGA TFT screen, 320 x 240, diagonal 148mm
Back lit LCD ¼ VGA colour LCD
12 x 8
IEC 61010, 1000V CAT III / 600V CAT IV IEC 61010, 600V CAT III
IP53 / IK08 IP54
USB USB, Bluetooth, Ethernet USB
Up to 13 hours9.6V NiMh rechargeable battery/ 30 minutes8.4V NiMh Rechargeable battery / Up to 13 hours7.2 V NiMh rechargeable battery /
200 x 250 x 70 mm / 2.0 kg 256 x 125 x 37 mm/ 1.0kg 211 x 108 x 60 mm/ 880g
42.5 to 69 Hz
+- +-
+- (0.5% + 2pts)+- +-(0.2% 0.4V)
± 0.5% + CT Accuracy
2 V to 1000 V ph-N
0.2% 0.02% Inom +- 0.5% + 1 A
±1% nom+- +-0.7% 0.007% P +-( 1.5% + 10pts); 0.5 < cos <0.8ø_
on V, I, VA up to 50 orderth
on V, U, I, VA & In up to 50 orderth
on V, U, I, VA up to 50 orderth
on V, U, I, VA up to 50 orderth
(0.5% + 1V)±
on V, U, I & In up to 50 orderth
1011
POWER CLAMPS
• High electrical safety standards IEC 61010, CAT III 1000 V (F407/607) / CAT IV 600 V (F205)
• IP 54 protection from water & dust
• Data recording – 3000 records (F407/607)
• Bluetooth interface and PC software (F407/607)
• True Inrush Current measurement with 1ms capture
• PAT software to download recorded data
SALIENTFEATURES
• AC / DC Voltage
• AC / DC Current
• AC/DC Power
• kW, kVA, kVAr
• PF, Co (F407/F607)sØ
• Min/Max, Peak
• True Inrush Current
• Wh, VAh, VArh
• THDf, THDr on V, U & I
• • Ripple Factor (F407/607)
• Resistance and audible continuity
Model F205 F407/ F607
Clamping Diameter 34mm 48mm 60mm
Display Backlit LCD Backlit LCD
Resolution 6,000 counts 10,000 counts
Current - AC+DC0.15 to 600 A
(900A peak)
0.15 to 1,000 A
(1,500A peak)
0.15 to 2,000 A
(3,000A peak)
Best accuracy 1% reading + 3 counts 1% reading + 3 counts
HzCurrent: 5.0 Hz to 3,000 Hz
(for A >10A)
Current: 5.0 Hz to 2,000 Hz
(for A>10A)
Voltage: 5.0 Hz to 20 kHz Voltage: 5.0 Hz to 20 kHz
1-phase & 3-phase total power values Yes Yes
Active power 5 W to 600 kW 5 W to 1,000 kW 5 W to 2,000 kW
Reactive power 5 VAr to 600 kVAr 5 VAr to 1,000 kVA 5 VAr to 2,000 kVA
Apparent power 5 VA to 600 kVA 5 VA to 1,000 kVA 5 VA to 2,000 kVA
Power Factor (PF) Yes Yes
DPF (Cos Ø) - Yes
V & I THDf & THDr Yes Yes
Individual harmonics -
Phase Rotation Yes -
Ripple - Yes
Functions
True Inrush (Over current Measurement) Yes Yes
Hold Yes Yes
Min / Max Peak+ / Peak- Yes Yes
Differential ΔX / Relative ΔX/X (%) Yes -
Data recording - Yes
Communication interface - Bluetooth
Electrical safety as per IEC 61010 600 V CAT IV 1000 V CAT IV
Power supply 1 x 9 V LF22 4 x 1.5V LR6
MEASURES
POWER CLAMPS
POWERCLAMPSF607/ 407/ 205Power Clamps with unprecedented performance
TECHNICALSPECIFICATIONS
measure �protect��conservemeasure���protect���conserve
Harmonics up to 25 order on V & I (F407/607)
th
Up to 25 order
th
12 13
ENERIUM SERIES ENERIUM SERIES
• Accuracy Class 0.2s as per IEC 62053-22
• Continuous sampling on all channels at 128 samples/cycle
• Backlit LCD graphical display
• Measures THD & Harmonics up to 50th order
• Stores events with time stamp & duration
• Stores Min/ Max of important parameters with time stamp
• Firmware Field-upgradable
• 6 DO Control / Alarms
• Memory for Data logging
SALIENTFEATURES
Description Specication
Accuracy 0.2s Class
Max I/O Channel 8
Flush Mouning Size 144 x 144
Digital Inputs Upto 8
Digital Outputs Upto 8
Analog Inputs Upto 8
Analog Outputs Upto 4
Voltage Inputs (AC)
Measurement Range 5 to 130% of V 110V / 400V
Measurement Accuracy
(U & V)0.2% from 20% to 130% of Vn Un
42.5 to 69 Hz
Current Inputs (AC)
Measurement Range1% to 130%
of nominal current 5A
Measurement Accuracy
0.2% from ≥10% to 130%, 0.5%
from ≥5% to ≤10%,
1% from ≥1% at ≤5%
(for ln=5A)
Auxiliary power supply
Power supply
80-265V AC (<15 VA),
42.5-69Hz; (Optional: 110-375V
DC / 19-57V DC (<10W))
Multi-measurement (accuracies)
±0.02 counts when 0.5 inductive
< PF < 0.5 capacitive
±0.05 counts when 0.2 inductive
< PF < 0.2 capacitive
Frequency ±0.1% from 42.5 to 69 Hz
Sampling Frequency 6.4kHz to 50 Hz
THD-V, U, I, Harmonics order ±0.5 counts
MEASURES
Description Specication
Trend Curves 1
Load Curves 8
Waveform Curves 16
Sags, swells Recording 1024
Phasor Yes
Gauges No
Harmonics Spectrum Yes
Digital inputs (on-off or metering pulse)
Operating VoltageHigh 10 to 70 Vdc,
Low 0 to 5 Vdc
Pulse or alarm relay outputs
Type / Operating Voltage/
max Current
Static relay
24 to 110 Vdc ±20%,
24 to 230 Vac ±10%/100mA
Compliance with standard IEC 62053-31
Analogue inputs
ScaleCongurable between
- 20mA and +20mA
Analogue Outputs
Scale -20mA and +20mA
Response time <500ms
Environmental specications
Operating temperature /
humidity / Storage temperature
Safety specications
Behavior in re U194, severity V1
Installation category 3
TECHNICAL SPECIFICATIONS
Compliance with standards
EN62053-22 (metering)
Active Energy Class 0.2s
Reactive Energy Class 0.5
(according to IEC 62053-23
method)
IEC 61557-12 Class 0.2
PMD SD/SS (power monitors)Active energy Class 0.2
Reactive energy Class 0.2
RS-485 output
CommunicationRS-485
(Optional Ethernet output)
Protocol MODBUS / JBus RTU mode
Speed (congurable) 2400 - 34,800
Voltage
Current, Neutral Current, Current Demand
Frequency - 50 to 60 Hz
kW, kVA, kVAr, PF, Cosø
4 quadrant energy kWh, kVAh, kVArh
kW & kVA demand
Sags, Swells, 1024 Events and Waveforms
• •
• • • • • • • Energy Accuracy as per IEC 62053-22
Use at:
▶ Incomers ▶ Substations
▶ Demand Control ▶ PQ monitoring ▶ Harmonic monitoring
Frequency
95% to 40 C / 0
-25 C to +70 C0 0
Applications:
Power factor (PF) and cos ø
ENERIUM 3000.2s Class Comprehensive Power Quality Meters
measure���protect���conserve measure �protect��conserve
-10 C to +55 C / 0 0
THD on V&I, Harmonics up to 50 orderth
14 1514
DiGi SERIES
DiGi 620/620HDiGi 720
INPUTS
Voltage
400V LL nominal; 480V LL continuous max
PT primary programmable up to 65kV
Current 5A nominal; 6A continuous max
CT primary programmable up to 9999
CT secondary selectable as 1A or 5A
Burden Voltage & Current input <0.2 VA per phase each
Overload Current 50A for 1s
Sampling Rate 128 samples/cycle on all 3 voltage and
3 current channels simultaneously
Isolation 2kV
Impulse withstand voltage 4kV(peak) -1.2/50µs
DISPLAY
Type Back-lit Custom LCD – 5 digit 3 line
AUXILIARY SUPPLY
Rating 85 to 265 Vac 50Hz; 100 to 300 Vdc
Burden 5VA
COMMUNICATION
Protocol MODBUS RTU with 16 bit CRC; 2-wire
Baud Rate Baud rate - 2400 bps to 38,400 bps
user-settable; Modbus ID - 1 to 247 except 99
DiGi SERIES
INPUTS
Voltage 400V L-L nominal; 480V LL continuous max;
Conguration -3 phase 4 wire/650kV
Current
5A nominal; 6A continuous max
(measurement from 50mA)
CT primary programmable up to 50,000
Burden Voltage & Current input <0.2 VA per phase each
Overload Current 50A for 1s
Sampling Rate 64 samples/cycle on all 3 voltage and 3 current
channels simultaneously
Isolation 6kV
Impulse withstand voltage 5kV (peak) -1.2/50µs
DISPLAY
Type Dot Matrix Back-lit LCD – 4 digit 3 line
AUXILIARY SUPPLY
Raing 85 to 265 Vac 50Hz; 100 to 300Vdc
Burden 5VA
COMMUNICATION
Protocol MODBUS RTU with 16 bit CRC; 2-wire
Baud Rate Baud rate 4800, 9600, 19200 bps user settable
GENERAL
Temperature Operating: -10°C to +55°C ;
Storage: -40°C to +70°C
Humidity <5% to 95% non condensing
IP Rating IP 52 front and IP 30 Case
ACCURACY
V 0.2% of Reading (10% to 120% nominal)
I 0.2% of Reading (1% to 120% nominal)
kW, kVA, kVAr 0.5% of Reading
PF 0.5% of Reading
Frequency 0.01 Hz
THD & Ind Harmonics 1% of Reading
kWh Class 0.5s as per IEC 62053-22
kVArh Class 2 as per IEC 62053-23
MECHANICAL
Terminals 2Rising Cage. 4mm (12 AWG) cable max.
Case PC/ABS Plastic FR Grade
Dimensions 96 x 96 x 58.6 mm
(45.1mm behind panel for main unit /
Additional 11.5mm for optional unit)
Cut-out 90 x 90 mm (+/- 0.5mm)
Weight 550 gm
GENERAL
Temperature Operating: -10°C to +55°C ;
Storage: -40°C to +70°C
Humidity <5% to 95% non-condensing
IP Rating IP 54 front and IP 20 Case
ACCURACY
V 0.5% of Reading (10% to 120% nominal)
I 0.5% of Reading (1% to 120% nominal)
kW 0.5% of Reading
kVAr 1% of Reading
PF 1% of Reading
Frequency 1%
Energy Class 0.5 as per IEC 62053-22
MECHANICAL
Terminals Rising Cage. 4mm (12 AWG) cable max.
Case PC /ABS Plastic FR Grade
Dimensions 96 x 96 x 83mm (65mm behind panel)
Cut-out 90 x 90mm (+/- 0.5mm)
• Accuracy Class 0.5s as per IEC 62053-22• ToU - 4 tariff rates, 8 periods and 2 lists of tariff rate• 2 Digital Outputs as standard for set-point alarms• 3 Status input as standard• True RMS upto 31 harmonics• Voltage input upto 480V• Phase sequence adjustment for easy installation• Optional
◦ Memory module for data logging & event recording ◦ 2 Analog Outputs (4-20mA) ◦ 2 Analog Inputs (4-20mA)
SALIENTFEATURES
Use at:
Applications:
▶ Incomers ▶ Substations ▶
Feeders
▶ Demand Control ▶ PQ monitoring ▶ Harmonic monitoring ▶ ToU Metering
• Accuracy Class 0.5s as per IEC 62053-22• True RMS upto 31 harmonic• Voltage input upto 480V• Phase sequence adjustment on communication• SMPS power supply• PT and CT programmable• Password protection• RS-485 port with Modbus RTU protocol• 2 Digital Inputs as standard
• Voltage – 3U, 3V, Unbalance• Current – 3I, In, Unbalance• Powers – kW, kVA, kVAr – phase wise and total• PF – phase-wise and total• Frequency• kWh, kVArh, kVAh• THD – V & I•
• stIndividual harmonics upto 31 order on communication
MEASURES
SALIENTFEATURES
Voltage – 3U, 3V, Unbalance• •
Current – 3I, In, Unbalance• Powers – kW, kVA, kVAr – phase wise and total• PF – phase-wise and total• Frequency• kWh, kVArh, kVAh• Demand & Max Demand – kW, kVA, kVAr, I• THD – V & I• Individual harmonics up to 31 order• st thHarmonic Energy (1 to 13 )• Min & Max 1s – V, I, kW, kVAr• K factor, Crest Factor
MEASURES
1A/5A models available
(For 1A- contact Atandra)
15
Applications:
▶ ▶▶▶▶
Use at:
Feeders Harmonic monitoringPower & Energy monitoringDepartments
Demand Monitoring
stHarmonics spectrum upto 31 order on display(only in DiGi 620H)
(only in DiGi 620H)
(measurement from 10mA)
®
measure �protect��conservemeasure���protect���conserve
2
0.5s Class Power Quality Meter 0.5 Class Power, Energy & Harmonic Meter
st
st
®
st
DiGi SERIESDiGi SERIES
• •
• •
Accuracy Class 1.0 as per IEC 62053-21Phase Sequence Adjustment
72 x 72mm SizeAccuracy class 0.5s as per 62053-22
• • True RMS upto 31 harmonicTrue RMS upto 31 harmonic • • Voltage input upto 480VVoltage input up to 480V • • SMPS power supplySMPS power supply • • 3 line LED display 3 line bright LCD display • • CT primary programmablePT, MF & CT programmable • • Password protec�onPassword protection • • 2kV isola�onLoad Management Module • • RS-485 port with Modbus RTU protocolOptional
SALIENTSALIENT FEATURES
FEATURES
MEASURES
Voltage – 3U, 3V• •
Current – 3I• Neutral Current• Powers – kW, kVAr – phase-wise and total• PF – phase-wise and total• Frequency• kWh, kVArh• kVAh (on Communica�on)
INPUTS
Voltage 400V L-L nominal; 480V L-L continuous max;
Conguration - 3 phase 4 wire
Current
5A nominal; 6A continuous max
(measurement from 50mA)
CT primary programmable up to 9999
Burden Voltage & Current input
<0.2 VA per phase each
Overload Current 50A for 1s
Sampling Rate 64 samples/cycle on all 3 voltage and
3 current channels simultaneously
Isolation 2kV
Impulse withstand voltage 4kV (peak) -1.2/50ms
DISPLAY
Type Seven Segment LED – 3 digit 3 line
AUXILIARY SUPPLY
Rating 85 to 265 Vac 50Hz; 100 to 300Vdc
Burden 2VA
COMMUNICATION
Protocol
Baud Rate Baud rate 4800 , 9600 user-settable
GENERAL
Temperature Operating: -20°C to +60°C ;
Storage: -30°C to +70°C
Humidity <5% to 95% non-condensing
IP Rating Ip54 front and Ip20 Case
ACCURACY
V 0.2% of Reading +/- 0.01V
(10% to 120% nominal)
I 0.2% of Reading +/- 0.01A
(5% to 120% nominal)
Power 0.5% of Reading +/- 0.1 unit
PF 0.5% of Reading +/- 0.001 unit
Frequency 0.01 Hz
Energy Class 1.0 as per IEC 62053-21
MECHANICAL
Terminals Rising Cage.
(4mm 12 AWG) cable max.
Case PC /ABS Plastic FR Grade
Dimensions 96 x 96 x 83 mm
(65mm behind panel)
Cut-out 90 x 90 mm (+1mm)
Weight
Use at:
▶ Loads ▶
Feeders▶ Power & Energy Monitoring
Applica�ons:Use at:
▶ LoadsDepartments ▶ ▶
▶Power & Energy MonitoringLoad Management
Applications:
Voltage - 3U, 3V, Unbalance• •
Current - 3I, In, Unbalance (On Communication)• Powers - kW, kVA, kVAr - phase wise and total• PF-phase-wise and total• Frequency• Energy - kWh, kVArh, kVAh• THD - V & I• • •
I & kW Demand , Max demand Individual harmonics up to 31 orderon communication (only in 520H)
MEASURES
2 status input (DI)2 relay output (250Vac / 5A) for alarms
INPUTS
Voltage 400V L-L nominal; 480V L-L continuous max;
PT ratio programmable up to 10000kV
Current
5A nominal; 6A continuous max
(measurement from 10mA)
CT ratio programmable up to 10000
CT secondary selectable as 1A or 5A
Burden Voltage & Current input
<0.2 VA per phase each
Overload Current 50A for 1s
Sampling Rate 64 samples/cycle on all 3 voltage and
3 current channels simultaneously
Isolation 2kV
Impulse withstand voltage
DISPLAY
Type Back-lit Custom LCD – 4 digit 3 line
AUXILIARY SUPPLY
Rating 85 to 265 Vac 50Hz; 100 to 300Vdc
Burden 2W/4VA
COMMUNICATION
Protocol MODBUS RTU with 16 bit CRC; 2-wire
Baud Rate Baud rate 4800 , 9600,19,200 user-settable
GENERAL
Temperature Operating: -10°C to +55°C ;
Storage: -40°C to +70°C
Humidity <5% to 95% non-condensing
IP Rating Ip52 front and IP20 Case
ACCURACY
V 0.2% of Reading (10% to 120% nominal)
I 0.2% of Reading (5% to 120% nominal)
kW
kVA,kVAr
0.5% of Reading
PF 0.5% of Reading
1% of Reading
Frequency 1%
kWh
kVArh
MECHANICAL
Terminals Rising Cage.
Case PC/ABS Plastic FR Grade
Dimensions 72 x 72 mm
(45.1mm behind panel for main unit/
Cut-out 68 x 68 mm (+/- 0.7mm)
Weight
6kV (peak) -1.2/50µs
<-
THD & Ind Harmonics 1% of Reading
Class 2.0
Class 0.5s as per IEC 62053-22
Additional 11.5mm for optional unit)
4mm (12 AWG) cable max. 2
550 gm
1416 17
350 gm
2
measure �protect��conservemeasure���protect���conserve
Min & Max - VL-L, VL-N, I, kW (On Communication)
DiGi 250Class 1.0 Power & Energy Meter
DiGi 520/520H0.5s Class Load Manager
MODBUS RTU with 16 bit CRC; 2-wire ®
st
st
®
st
SALIENTFEATURES
DiGi SERIES
MULTY 4 DiGi COMPARISION
INPUTS
Voltage 400V LL nominal; 500V LL continuous max
Current
Selection of 100A or 200A primary CT
Burden Voltage & Current input <0.2 VA per phase each
Overload Current 50A for 1s
Sampling Rate 64 samples/cycle on all 3 voltage and
3 current channels simultaneously
Isolation 2kV
Impulse withstand voltage 6kV (peak)
DISPLAY
Type Back-lit Custom LCD – 4 digit 1 line
AUXILIARY SUPPLY
Rating 85 to 265 Vac 50Hz; 100 to 300 Vdc
Burden 2VA
COMMUNICATION
Protocol
Baud Rate 4,800 bps, 9,600 bps
GENERAL
Temperature Operating: -10°C to +55°C ;
Storage: -40°C to +70°C
Humidity <5% to 95% non condensing
IP Rating IP 52 front and IP 20 Case
ACCURACY
V 0.5% of Reading (10% to 120% nominal)
I 0.5% of Reading (5% to 120% nominal)
kW, kVA
kVAr
1% of Reading
2% of Reading
PF 1% of Reading
Frequency 1%
kWh Class 1 as per IEC 62053-22 including CT errors
kVArh Class 2 as per IEC 62053-23
MECHANICAL
Terminals 2Rising Cage. 4mm (12 AWG) cable max.
Case PC/ABS Plastic FR Grade
Dimensions 75 x 94 x 58.6 mm
35 mm
Weight 550 gm
Use at:
Applications:
▶ ▶
▶
MEASURES
DiGi SERIES
C- Available on Communication
Common for all channels:Ÿ Voltages - L-N and L-L (C)Ÿ FrequencyŸ Voltage Min and Max - L-N and L-L (C)
For each of the 4 channels:Ÿ Currents - LineŸ Max Currents - Phase-wise (C)Ÿ Power Factor - phase and totalŸ kW, kVA, kVAr - Phase and totalŸ kWh - Phase wise and totalŸ kVAh - Phase wise and total
Ÿ Accuracy Class 1.0 as per IEC 62053-22 (Accuracy includes CT Errors)
Ÿ 75mm (width) x 94mm (height) x 62mm (depth)Ÿ Voltage input up to 500V Ÿ CT Primary Programmable Ÿ 2kV Isolation Ÿ Password Protection Ÿ Backlit custom LCD display Ÿ Load Management Module Ÿ Special high-accuracy CT supplied with the meter.
100mA input
Din-Rail
Loads Feeders Power & Energy Monitoring
measure �protect��conservemeasure���protect���conserve18 19
4 Channel Load Manager
MODBUS RTU with 16 bit CRC; 2-wire ®
Parameter / Feature DiGi 250 DiGi 520/520H DiGi 620/620H DiGi 720 MULTY4
3V, 3U, Hz
3I, In
kW, kVAr, PF – Total & Ph
■ 3U (only on C)■
■
■
■
■
■
■
■
■
■
■
■
■■
■
■
■ ■ ■ ■
■ ■ ■ ■ ■
■ ■
■
■
■ ■
■
■
■
C
■
■
■
■
■
■
■
■
■
■
■
■
kVA
kWh, kVArh
kVAh
Demand & MD
THD
Min & Max – 1s (V & I)
TOU
K-Factor, CF
Harmonic Energy
Load Management Module
CT Programming
PT Programming
Digital Inputs
Digital outputs
RS-485 port
Accuracy
Data Recording
Analog Inputs & Outputs
Individual Harmonics
Ethernet Port
C
C
C
Class 1.0 Class 0.5s Class 0.5s Class 0.5s Class 1 (including CT)
Up to 31 (C)
(in 520H) (in 620H)
Up to 31(C) nd 2 to 31 Order Display
Upto 13
Y/N
2 3
2(optional) 2
Optional
Optional
Optional
Optional
Only 3I
nd2 RS-485 port
th
st stst
THERMAL CAMERA
2120
THERMAL CAMERA
TECHNICAL SPECIFICATIONS
TCA 1950
THERMAL IMAGERThe TCA 1950 is a handy Thermal Imager that makes it very simple
to perform thermal inspections for energy audit and ensures trouble-
free industrial, electrical or mechanical maintenance.
•• • • • • •
• • • •
EVEN MORE USER-FRIENDLY AND SIMPLE TO USE
THANKS TO:
NEW
Just 3 seconds to start-20 C to +250 C80 X 80 Sensor13 hours battery lifeVoice messages can be stored with imagesRugged - 2m fall resistanceCAmReport Software for PC Download & analysis
The exceptional 13-hour battery lifeAn emissivity table which can be added to as requiredThe possibility of renaming images and thermograms by siteRecording and storage of the congurations according to the application(building, electrical cabinet, etc.)
KEY FEATURES
DETECTOR SPECIFICATIONS
Detector 80 x 80
Type UFPA microbolometer, 8~14µm
Frequency 9 Hz
TEMPERATURE MEASUREMENT
Temperature Range
Accuracy ± 2°C or ±2% of reading
THERMAL IMAGE PERFORMANCE
Field of View 20° x 20°
IFOV (spatial resolution) 4.4 mrad
Focus Fixed
Minimum focal distance 40 cm
Real image Yes (320 x 240 Pixels)
Display mode Thermal image, Real image with automatic parallax compensation. Merging of both images possible with PC software
FUNCTIONS FOR ANALYSIS
Measurement tools
Parameter Settings
Vocal comments
F407 and F607 clamps
Data storage
Removable, up to 32 GB
On 2 GB micro SD card (approx. 4,000 images) removable up to 32 GB
PRESENTATION OF IMAGE
Adjustment Automatic or manual adjustment of palette min-max
Freezing of image Animated or xed image
Image display Multi-palette
Screen 2.8 inches
POWER SUPPLY
Type NiMH rechargeable batteries with low self-discharge
Recharging External (charger provided)
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature -15°C to +50 °C ( -4°F to +122°F)
Storage temperature -40°C to +70°C (-40°F to +158°F)
Humidity 10% to 95%
Standards EN 61326-1: 2006 / EN 61010-1 Ed.2
Fall resistance 2 metres on all surfaces
Shock resistance 25G
Vibration resistance 2G
PHYSICAL SPECIFICATIONS
Weight / Dimensions 700 g with rechargeable batteries / 225 x 125 x 83
Ingress protection IP 54
Interfaces - USB link and Mass Storage function: the product is then recognized as a USB drive for easy transfer of the images
- Bluetooth for connectivity with earphones (vocal comments) and measuring instruments (F407,F607)
Yes with ¼” insert on the camera
GENERAL SPECIFICATIONS
Report creation software Supplied as standard with automatic report generation in .pdf or .dox (word) format/ compatible with W7 and W8,
32 and 64 Bits
80 mK @ 30°C (0.08 °C @ 30 °C)Sensitivity
1 manual cursor + 1 automatic detection + min-max on adjustable area + temperature prole + Isotherm
Emissivity, environmental temperature, distance, relative humidity
Yes via Bluetooth
Connectivity
.bmp (thermal and real images recorded simultaneously)
-20°C to +250°C
Tripod Mounting
measure �protect��conservemeasure���protect���conserve
HARMONIC FILTER
• Avoid penalties from EB• • •
• • •
SALIENTFEATURES
ADVANTAGES
• IGBT design and Digital Fast Fourier Transform based harmonic compensation helps eliminate
• • •
• • • •
TruSine Series
ACTIVE HARMONIC FILTER
TECHNICAL SPECIFICATIONS
HARMONIC FILTER
NEW
rd stharmonics from 3 to 51 orderOption to mitigate selective harmonics or global harmonicsAutomatic PF improvement up to the unutilized capacity of lterAbility to connect up to 40 units of different ratings in parallel; Master-Slave combination or PeercombinationHarmonics attenuation up to 97% at rated current and prevents possible harmonic resonanceVoltage independent harmonic current tracking for more immunity to input voltage distortion Inherent current limiting will prevent overload conditionOption of 3ph 3 wire / 3 ph 4 wire conguration; option of 690V model
Avoid machinery failuresMinimise tripping of switchgearIncrease Transformer & DG utilisation factors Reduce cable losses and failures
Avoid Capacitor Bank failuresImprove PF thereby reducing demand
22
Input Power Source415 Vac, 3-Ph,3-wire,50 Hz 415 Vac, 3-Ph,4-wire,50 Hz 600 Vac, 3-Ph,3-wire,50 Hz
Voltage -15% to 10%, Frequency +5%-Filter current in each phase(Arms)
30 60 100 100 100150 150150200 200 220200300 60
Heat loss(Watt) <- <- <- <- <- <- <- <- <- <- <- <- <- <-1200 2000 3000 5000 6100 7000 2100 3100 5150 6250 4300 6000 8000 8500
Control Method
Harmonic ltering &Order Section
Harmonic Attenuationratio
Response time
Digital inputs
Digital Outputs
Potential Free Contacts
Programmable Analog outputs
Display and keypad module
Communication
Protective functions
Fault history
ElectronicThermal Overload
Installation location
Type of cooling
Forced air cooling
Model deratingwith temperature
Humidity
Protection class / colour
Dimensions
Approximate Weightin kg[lb]
Installation
Dimensions (W X DX H)in mm
Harmonic - Referencestandard
Safety
Digital Fast Fourier Transform with hysteresis current control
Harmonics orders up to 51,Global / selective compensation from 3 to 51 order with settable amplitude
Better than 97% at rated current
One cycle (20ms)
5-Programmable sequence inputs, sink/source changeable
4-Programmable sequence outputs, open collector type
3-Programmable relays with 1-NO,1-NC for 5A @ 240 VAC, Programmable between 12 different options
2-Programmable analog current outputs IO1 & IO2: 4~20mA
4-Line LCD Panel
THDv, Line frequency, DC bus voltage, PF, DPF, kW, kVA, kVAR, VL-L
Current of Filter/ Load / Source side for each phase, I-THD of Load and Filter side
RS-485 port with Modbus-RTU protocol
Over current
AdjustableOver current
Timed over current
DC bus over voltage
DC bus under voltage
Over temperature
Phase Loss
Ground Fault
External Fault
Charging fault
EEPROM fault
CT Detection fault
Last ten faults - with status at time of fault- are stored in memory
120% overload for 60 seconds, above 100% harmonic current is limited by software
Indoor
Ambient Temperature Storage Temperature
0°C ~40°C -20°C~70°C
Above 40°C, derate the output current by 3% /1°C Maximum up to 55°C temperature
0~95% maximum, non condensing
IP 31(optional- higher protection requirements) / RAL 7035
A A B B B B B Bc c c cc c
80
[176.4]
90[198.4]
272
[599.6] 280
[617.3] 350
[771.3] 430
[948] 251
[553.4] 280
[617.3] 320
[705.5] 422
[930.3] 275
[606.3] 360
[793.7] 470
[1036] 470
[1036]
A=Wall/Floor mounting, B, C= Floor Mounting
A=480 X 370 X 1065
IEEE 519-1992, G5/4-1, GB/T 14549-93, IEC 61000-3-2, IEC 61000-3-4
B=600 X 600 X 1960 C=800 X 600 X 2160
IEC 50178
measure � ��conserveprotect 23measure ���conserve���protect
st
rd st
SERVO STABILISERS
3 PHASE SERVO STABILISERSQuality makes a difference
APPLICATIONS
CNC machine tools
Injection Moulding machines
Textile machines- Spinning, Weaving,Knitting, Embroidery, Garments manufacturing
Printing machines
Medical Equipment
Food Processing machines
Air Conditioning
COMPREHENSIVEPROTECTION
Under / over voltage trip - The trip points can be set as per machine requirements
Electronic Overload trip-CT based current sensing for accurate and reliable protection, activates beyond 110% of rated current, with programmable time delay to override inrush currents
Short Circuit protection
Single phasing protection
Phase reversal protection
Manual service bypass for emergenciesEmergency stop for safety
ALSO AVAILABLE
1 phase Servo Stabilisers
2 phase Servo Stabilisers
3 phase input / 1 phase output Servo Stabilisers
3 phase Residential Servo Stabilisers
Isolation Transformers
Stabilisers with built-in Isolation Transformers
Parameter 3 Phase Unbalanced Air cooled 3 Phase Unbalanced Oil Cooled
Rating (kVA) 3-150 3-3500
Type of cooling Air Oil
Input Voltage range (V L-L)*
Output Voltage Regulation
Input Frequency Range
Efciency
Effect of Load Power Factor
Output Voltage (V L-L)*
Waveform Distortion
310-480 / 340-480 / 360-460
415 (380V/400V - Optional)
1% of nominal output voltage
47Hz- 53Hz
>97%
Type of Servo Control
Servo Motor Drive
Under/ Over Voltage Cutoff*
Overload cutoff
Short circuit protection
Single Phasing Prevention
Phase Reversal Trip
Stabiliser bypass
Transient Supression
Emergency Off Switch
Frequency cut off protection
Input High Voltage Trip
Resetting mode
Display Type
Parameters displayed
Parameters displayed
LED indications
Input/Output Terminations
Nil
Nil
Micro controller based True RMS sensing and correction
Triac based drive for AC Step Synchronous motor
Electronic cutoff circuit with graded time delay,set @ +5% / -10% of nominal output voltage
CT based Electronic cutoff circuit with graded time delay,set @ 110% of rated full load current.
MCB/MCCB provided upto 100 kVA. Above 100 kVA HRC fuse(MCCB optional)
Provided
Provided
Provided up to 50 kVA 3-phase; Optional > 50kVA
Spike Suppression through MOV is provided (Surge Arrestor is optional))
Provided
Optional
Optional
Manual / Auto option provided with programmable time delay
2 Line LCD Panel
Input & Output Voltages (Line & Phase), Output Currents & Frequency
Fault Annunciation, Event Log
Non Latching LED lamps for Input Present, Output Normal, MCB Trip, Stabiliser Bypass (if Bypass Switch is provided)
Bolted terminals upto 100kVA, Busbar 125kVA and above
SERVO STABILISERS
24 25measure � ��conserveprotectmeasure ���conserve���protect
* Customs ranges are available
ISOLATION TRANSFORMERS ISOLATION TRANSFORMERS
ISOLATION
TRANSFORMERSDesigned to save energy costs while protecting your equipment
Transformers are critical equipment in the power supply chain of every industry and work 24/7 in most cases. The
quality and efciency of transformers therefore are very critical and make a signicant difference to the industry
both in terms of uptime and energy costs. Considering the importance of this, we are offering innovatively.designed efcient transformers that help industries through superior performance and lower energy losses.
With over 250,000 installations working since 1993 in various applications, our transformers have a proven track record of performance over a long life-cycle
PRODUCTRANGE
Ultra Isolation TransformersK-rated TransformersGalvanic Isolation TransformersAuto Transformers
Parameter 3-Phase 1-Phase / 2-Phase
Rating
Reference Standard
Type of transformer
Conguration
Default Vector Group
Type of lamination
Winding
Load regulation
Class of insulation
Efciency
Insulation Strength
DC galvanic isolation
Common Mode noise rejection
Short Circuit Protection
Indications
Housing
3kVA to 1000kVA 1kVA to 25kVA
IS 11171 : 1985 (Reafrmated 2006)
Floor mounted, natural air-cooled /oil-cooled (depending on rating)
Dry type, oor mounted, natural air-cooled
Delta/Star 1:1 (or as per user specication) 1:1 (or as per user specication)
Dyn11
CRNO
Aluminium Wire / Strip or Copper Wire / Strip
Withstands 2.5kV for 1 minute (between windings & between windings and body)
Better than 3%
Class H
3-12 kVA(>95%)>15 kVA (>97%)
At rated input voltage and at 100% rated current of loads that are linear
> 1000 Mega Ohms- for UIT> 100 Mega Ohms- for GIT
Up to 10 kHz > 100 dB 10 kHz to 50 kHz > 60 dB50 kHz to 1 MHZ > 40 dB
HRC fuse at input provided as a standard /MCB/MCCB can be provided as an option
LED Lamps for Output PresenceDigital Voltmeter (DVM) - optional
Sheet metal housing provided with input/output terminations
TECHNICALSPECIFICATIONS
26 27measure � ��conserveprotectmeasure ���conserve���protect
LIGHTING ENERGY SAVERS LIGHTING ENERGY SAVERS
A cost-effective way to conserve energy of lighting loads without any heavy instruments or cumbersome changes in light ttings
SUITABLE ON
ENERGYSAVINGS
PROTECTION
QUALITY OF LIGHTING
Old lighting installations with copper chokes
Lighting with a combination of Electric Ballasts and Copper
Chokes
Lighting with Electric Ballasts/T5 tube lights
Saves up to 25% energy
Works effectively on all types of lighting
Improves PF reducing cable losses
Reduces kVA Demand
Increases lamp life and reduces replacement costs
Reduces THD on current xtures that generate harmonics
Ensures consistency of lighting which enables better productivity
KEY FEATURES
Seeing is Believing
kW/kVA/PF and Energy data forinstantaneous assessment of savings
5 Time Zones
Set up to 5 different time zones forvoltage control depending on yourneeds
Phase-wise Control
Set different voltages in each phasefor each time zone; phase-wisecontrol possible
Flexible Operation
Suitable for 24x7 operations or forxed hour operations
Suits all Lamp Types
Works even on Sodium Vapour,Mercury Vapour and Metal HallideLamps
Auto Load Change Sensing
Shifts to Regular voltage for a presetperiod and back to Energy Savermode, when there is an increase inload current
TECHNICAL SPECIFICATIONS
Specication Wide Range ModelRegular Range
Air-cooled ModelRegular Range
Oil-Cooled Model
Rating 3-ph 9 kVA and above
Recommended Input Voltage Range 160-260 V LN 205-255 V LN
Working Input Voltage Range 150 - 290 V LN 190-280 V LN
Time Zones
Output Setting
Auto Bypass
Parameters Measured
Mounting
Bypass
Total of 5
From 160 V to 250 V LN
Yes
V,I,PF,kW,kVA,kVAR,kWh,Hz
Floor mounted on wheels or can be grounded using foundation bolts
Only in case of LES fault/ User selectable Manual bypass
LIGHTING ENERGYSAVERS
2928 measur ��e �protect conservemeasure protect������ conserve
ENERGY MANAGEMENT SOFTWARE
A new way of visualising data
A Central hub for
No limitations on data
A wide variety
ALENSOFT on Premise
•
•
•
•
ALENSOFTVERSIONS
of reports
ALENSOFT presents data in easy to view dashboards. Criticalinformation and deviations are visible at a single glance, so that you can focus on taking action, armed with the right data.
ENERGY MANAGEMENT SOFTWARE
30 31
ENERGY MANAGEMENT SYSTEM
measure �protect��conservemeasure protect������ conserve
ALENSOFT can integrate not just electrical energy usage, but also monitor the usage several other resources like water, air, diesel and steam. Viewing and analysing a consolidated usage prole of all energy resources is just a matter of a few clicks.
There are no tag or parameter limitations. Data from all devicesconnected is available in real-time and over time.
ALENSOFT has numerous reports and views that help you get a bettergrasp of your entire factory or facility. Whether you need an analytical report to help you take a considered decision, or acomprehensive report on the performance of your equipment, it’s available.
Desktop or Local server based solution that is installed at your factory, where the data resides in the local server only
A fully loaded solution with a perpetual license, based on the number of nodes connected to the system.
Modular structure with an ability to add or remove modules, depending on your requirement
ALENSOFT on Cloud
Cloud based solution that is available as a service
Data is stored in Atandra’s cloud servers
Flexible subscription based model, with an ability to scale the network size, as well as add application modules, based on your requirement
•
•
Monitoring
32
SOME OF OUR CLIENTS
OUR DEALER
No. 5, Kumaran Street, Pazhavanthangal, Chennai - 600 114