casperpower.comcasperpower.com/uploadfile/Casper Power CP-W30.pdf ·...
Transcript of casperpower.comcasperpower.com/uploadfile/Casper Power CP-W30.pdf ·...
1
Weichai series
CP-W30
Notice: the picture is just for reference only.
■ Engine: Weichai K4100D
■ Cooling Fan with fan guard and front guard
■ Alternator: Single bearing, IP23, H class
■ 2*12V Start Battery with connection cable
■ Equipped with Shock Absorber
■ Dry Air Filter, Dual Fuel Filter, Engine Oil Filter Coolant Filter
■ Standard Control Panel, Circuit Breaker
■ Storage Battery and battery line, Exhaust pipe
■ Corrugated pipe for anti-vibration, Cone Tube, Flange, Muffler
■ ATS (automatic transfer switch) receptacle
■ Soundproof Enclosure/Canopy for optional
■ Base fuel tank for at least 8hours running
■ Equipped with an industrial muffler
■ Engine oil pump
■ Drainage for fuel tank
■ Documents
Notice:the size and weight is just for reference, if you
Want to confirm it, please kindly confirm it with salesman,thanks.
Generator model..............................................................CP-W30
Rated Power..............................................................24Kw/30Kva
Standby Power........................................................26.4Kw/33Kva
Voltage............................................................................230/400V
Frequency..............................................................................50Hz
Speed..............................................................................1500rpm
Type.......................................................................3 Phase 4 Wire
Engine Model......................................................Weichai K4100D
Alternator.........................................................................CP-184G
Control System................................................Smartgen HGM170
Circuit Breaker.................................................................Standard
ATS (automatic transfer switch).......................................... Option
Silent Level...........................................................70dB-85B at 7m
Fuel Tank Capacity.........................................8-12 hours fuel tank
Fuel Consumption................................................................6.9L/h
* Voltage Available:50Hz: 380-400-415V/220-230-240V;60Hz: 220-380-416-440-480V/110-208-220-240VAny special voltage is also available as client’s request
*Prime Power: Prime power is available for an unlimited number of annualhours in variable load Application, in accordance with GB/T2820-97 (eqvISO8528); A 10% overload capability is available for a period of 1 hour withina 12 hour period of operation.
*Standby Power: The standby power rating is applicable for supply emergencypower for the duration of a utility power interruption. No overload, utilityparallel or negotiated outage Operation capability is available at the rating.
Dimensions and WeightsGenset Type Length (L) Width (W) Height(H) Weight
Open Type 1600mm 640mm 1100mm 960kg
Silent Type 2000mm 900mm 1200mm 1200kg
2
■ Diesel engine
Engine brand.....................................................................Weichai
Engine model....................................................................K4100D
Aspiration..........................................................Natural Inspiration
Type.............................................4 Stroke,in line ,Swirling pattern
Speed/Frequency...................................................1500rpm/50Hz
Rated Power..........................................................30.1Kw/40.9hp
Cylinder........................................................................................4
Displacement........................................................................3.61L
Bore*Stroke..........................................................100mm*115mm
Compression Ratio.................................................................19:1
Fuel consumption....................................................≤258.4g/kw.h
Governing System.......................................................Mechanical
Starting method.....................................................Electric Starting
Cooling system.........................................................Water-cooled
■ Alternator
Alternator model..............................................................CP-184G
Alternator manufacturer................Fuzhou Casper Power Co.,Ltd.
Speed/Frequency...................................................1500rpm/50Hz
Rated power...............................................................24Kw/30Kva
Standby power........................................................26.4Kw/33Kva
Connection............................................................3 Phase 4 Wire
Wings.......................................................................100% Copper
Altitude condition...............................................................≤1000m
Excitation...............................................Brushless, Self-excitation
Insulation class/Temp.rise class...............................................H/H
Tel.influence factor TIF.............................................................<50
Tel.Harmonic Factor THF........................................................<2%
Steady state voltage regulation.............................................≤±1%
Efficiency..............................................................................93.8%
Cooling air flow..............................................................1.035m3/s
Power Factor…………………………………………………….…0.8
■ ATS (OPTION)
Upon detection of a mains(utility) failure the module
automatically starts the generator set, once the mails (utility)
power has been restored it instructs the generator set to stop
■ Control panel (OPTION)
Our factory have Smartgen, Deep sea, Comap,Harson or other
brand controller for our customer’s choice, If you need these
controller, please kindly talk with the salesman about the
controller cost.
■ Single Phase& Three Phase Outlet (OPTION)
■ Mobile Generator (OPTION)Two Wheels:
Four Wheels:
3
■ Control system (Standard)The Smartgen HGM170 is a generator control module designed
to start and stop the engine via a key switch and push buttons on
The front panel or remote start signal. When detecting faults
(low oil pressure, high water/cylinder temperature, auxiliary alarm
over speed), it will discount fuel relay and energize to stop. LED
annunciator display the faults, which can offer real and effective
alarm informations.
___________________________________________________
a. Voltage Meter Gauge i. Genset Controllerb. Frequency Meter Gauge j. Oil Pressure Gaugec, Ampere Meter Guage K. Water Temperature Gauged. Hours Counter l. Fuel Level Gaugee. Voltage Switch m. Generating Lampf. Charge Meter Guage n. Fedback power Lampg. Ampere Switch
Feature
Wide range of DC supply.
Low oil pressure, high water/ cylinder temperature, over speed
Protection and indication.
With charge failure indication: warn, not shutdown.
An auxiliary shutdown alarm signal.
Speed signal comes from generator frequency.
LED displays various alarm states.
With fuel output, start output, preheat and stop output.
Modular structure design, ABS plastic case, plug-in installation,
Compact structure with small volume, advanced SCU control,
Stable performance and convenience operation.
Measure and Display1.The AC phase voltage of generator V2. Generator frequency Hz3. The Ampere of generator A4. Battery voltage Vdc5. Engine running hours H6. Engine coolant temperature ℃/℉
7. Engine oil pressure BAR/PSI8. The base fuel tank fuel level L
1.High Temperature Indicator 7. Stop Position2. Low Oil Pressure Indicator 8. Manual Button3. Over Speed Indicator 9. Auto Position4. Charge Failure Indicator 10. Stop Button5. Common Alarm Indicator 11. Key Switch6. Failure LED Button
Alarm and Protection1. Low oil pressure 5. Auxiliary stop alarm
2. High temperature 6.Fail to start
3. Over speed 7. Fail to stop
4. Charge failure 8. Common alarm
ManualTurn the key to Manual model, press this
key to start genset.
Stop/Reset
Can stop the running geset.
Can reset alarm.
PreheatIn Manual Model, press this key to
output preheat signal.
Stopposition
When genset at rest, turn key to stop
position, controller will be in a low power
consumption standby mode.
Autoposition
Turn the key to auto positon, When
remote start is enabled, genset will start
automatic.
4
■ Control system (AMF for Option)Smartgen HGM6120 Genset controller integrating digital,
intelligent and network techniques is used for automatic control
system of diesel generator. It can carry out functions including
automatic start/stop, data measure and alarm protective. The
controller uses LCD display.
___________________________________________________
1. Controller 4. Key Switch2. City Power Indicate 5. Fuel Guage3. Genset Power indicate
Feature
132*64 LCD display with backlight, optional language interface
(English) push-button operation.
With RS485 communication port, can achieve “three remote”
Function via MODBUS protocol.
Adopt to 3P4W,3P3W, 1P2W or 2P3W (120/240V),50/60Hz
AC power system.
Can Measure and display 3 phase voltage, 3 phase current,
frequency, power etc Mains and Gens.
Precision measure and display parameters about engine.
Control protection: Automatic crank/stop of diesel engine. Load
transfer and completely faults display protection.
With ETS, idle control, pre-heat control, Raises speed control
functions, and all type of them are belong to relay output.
Parameter setting: Allow user to modify setting and store them
by inside internal FLASH memory, the parameter can not be
lost even with power off, all of parameters can be set not only
from the front panel, but also use programmable interface or
(RS485 interface) to adjust them via PC.
All parameters use digital modulation, abandoning analog
Modulation using conventional electronic potentiometer, more
Reliability and Stability.
a. Stop/Reset Button i. Page Up Buttonb. Manual Button j. Set/confirm Buttonc. Auto Button k. Running Indicated. Running With Load Button l. Alarm Indicatee. Menu Button m. Gens Normal Indicatef. Start Button n. Gens On Load Buttong. Page Down Button o. Mains On Load Button
p. Mains Normal Indicate
Generator Protection
Warning1. Lost Of Speed 2. Gens Over Current
6. Failed To Stop 4. Low Oil Level
5. Charge Alternator Fail 6. Battery Low Voltage
7. Battery High Voltage 8. Low Water Level
When controller detects the warning signal, only alarm
and not Stop genset, the alarms are displayed in LCD.
Shutdown Alarm1. Emergency Stop 2. High Tem Alarm
3. Lower OP Alarm 4.Over Speed Alarm
5. Under Speed Alarm 6.Speed Signal Lost Alarm
7. Gens Over Voltage 8.Gens Under Voltage
9. Gens Over Current 10.Start Fail Alarm
11. Over Frequency Alarm 12.Under Frequency Alarm
13. Gens Failed Alarm 14.Oil Level Lower Alarm
15. Water Level Lower Alarm
When controller detected shutdown alarm, it will
Send signal to breaker off and to stop, the alarms
And displayed in LCD.
5
■ Standard Accessories
■ Standard Accessories
■ Generator Structure
■ Quality AssuranceFactory Inspection, the test items before delivery are mainly as follows:1. Each genset shall be put into commission more than 4 hours totally.2. They are tested on idle load, fully load and 110% overload;3. The noise level is tested4. All of the meters on the control panel shall be tested5. The appearance of the genset and all of the label and nameplate shall be checked
Warranty
12 months or 1000 running hours from shipment date. If the quality problem arise during the warranty period,andverified the problem is caused by our genset-body instead of external or natural reasons. (Refer to all kinds ofnatural disaster, shipping, loading, unloading, wrong-operation, etc),we will supply the relevant spare parts free ofcharge for maintenance;after the warranty period, we can supply the required spare parts for you under cost prices.
Standard Battery Battery Charger Battery Wire Flexible Pipe
Cooling Radiator Float Battery Charger Control System Base Frame
Flange Wire diagram Manual Book
ATS External Fuel Tank Silent Canopy PMG Water Preheater
Synchronization
Panel
Automatic Fuel Tank Weatherproof
Canopy
Auto-condensation
heater
Lub Oil Preheater
ABB Breaker Oil Drain Pump Mobile trial Paralles droop Spare parts
6
■ CASPER SILENT GENERATOR OVERVIESCasper Silent generator is designed according to the international quality standard, which meet thespecial requirements of environmental protection and user , scientific design, acoustics, air flow in the field ofadvanced technology, lower noise, adapt to the city environmental requirements mute cover , good ventilationseries and prevent heat radiation measures to ensure that the unit is always working in a suitableenvironment temperature.
Generator Feature* Good ventilation system and prevent heat radiation measures to ensurethat the unit is always working in a suitable environment temperature* Large capacity base fuel tank, available for 8 to 12 hours continuous load operation* Dedicated noise reduction silencer material, to a great extent suppression of mechanical noise* The efficient damping measures to ensure the smooth running of the diesel generator set* The appropriate location of the muffler shell dedicated observation window andemergency stop button , convenient to use operation and observation unit operating status
The Installation of Generator1 , the installation site need to maintain good ventilation , generator terminal should have sufficient air inlet , thediesel engine side should be a good outlet . The vent area should be greater than 1.5 times more than the area ofthe tank.
2, the installation of around should be kept clean to avoid the items placed in the vicinity of acidic, alkaline andother corrosive gases and vapors can produce . Conditional fire extinguishing devices should be configured.
3. for indoor use, you must exhaust pipes pass to the outdoor, the diameter must be ≥ muffler smoke tubediameter, connected to the pipes of the elbow should not be more than 3 to ensure the smooth flow of exhaust gas,and shall pipe downward-sloping 5 - 10 degrees, avoid rain water injection; exhaust pipe is installed verticallyupwards, you must install rain cover.
4. The concrete foundation is required in the installation Use the level to measure the level of the unit fixed on thebasis of the level. Between the unit and the foundation should be a dedicated anti-vibration pad or foot bolt.
5, the unit housing must have reliable protection grounding directly grounded neutral point generator, it must becarried out by professionals neutral ground, and equipped with lightning protection devices, prohibit the use of thethe mains grounding device neutral point directly to ground.
6, the two-way switch for generator and mains must be very reliable, to prevent reverse power transmission.Two-way switch wiring reliability and subject to the approval of the inspection of the local electricity sector.
7 starter battery connections must be secure.
Generator ApplicationThe Silent Generator widely used: defense , hospitals , hotels , schools , factories , families , construction ,building ,Telecommunications, marine , industrial and mining enterprises , railway and highway construction , oilexploration , water conservancy construction , can be used as a backup power supply or emergency powersupply .
7
Generator Transportation1.Forkman hole can be choice2.Lifting hole is standard mounted in the base fuel tank
The Certificate of Generator Quality1. Certificate of Europe (CE)2. China Compulsory Certification (CCC)3. International Organization for Standardization (ISO)4. Standards Organization of Nigeria (SONCAP)
Note:We also can make SASO, COC, PVOC, BV etc for our customer. Please contact with salesman for these fee, thanks.
FUZHOU CASPER POWER CO.,LTD.Add: 1026 Unit Thaihot Plaza, 6# Banzhong Road, Xindianzhen,
Jinan District, Fuzhou, Fujian.
Tel:+86-591-87902959
Fax:+86-591-38253236All information in this documents is just for reference only, if any changes without Notice,thanks.
Distributed by